Origo PhaseID System

The PhaseID System now makes it possible to quickly

and easily determine energized phase attributes anywhere in your system.

Use it on primary, secondary, overhead,

underground, livefront, deadfront, transformers,

switching cabinets, substations, and standard

120-volt receptacles.

Page 3: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

How it Works

The basic concept of the PhaseID System is very simple. GPS timing signals are used to

obtain snapshot phase measurements at an unknown field location and at a known

reference location at the same instant of time.

When these two measurements are compared, the phase

attribute at the unknown field location can be determined.

Page 4: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Why it is Needed

Simply put, complete system phase knowledge is required to operate a

smooth, balanced, efficient, well maintained utility.

For example, phase knowledge allows

distribution load balance to be obtained and maintained

as new customers are added.

Page 5: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Benefits of Phase IdentificationGeographical Information Systems (GIS)

These systems are only as good as the data they contain. When GIS phase attribute data is incorrect, the usefulness of these important data bases are greatly diminished. A phase identification system allows you to easily and accurately correct your phase maps.

Reduce Outage Management Errors

An accurate outage management data base allows a utility to instantly determine which feeder has tripped based on customer outage calls. However, if the phase attribute data associated with individual customers is wrong, time is wasted directing a troubleman to the wrong fuse or breaker. A phase identification system allows you to correct these data base errors.

Load Imbalance

As new customers are added, or due to seasonal load changes, feeder loads may have to be re-balanced by switching loads from one phase to another. If the phase load being switched is connected to one that is not accurately known, phase balancing becomes a time consuming and frustrating process. Instead of moving load from “C” to “A”, you might be really moving load from “B” to “C”, which makes the problem worse instead of better. With a phase identification system, cables can be accurately tagged.

Wasted Crew Time

Hours are wasted daily with entire crews waiting while attempting to identify phasing. The current practice of “driving a line” to determine phase is no longer necessary. A phase identification system can accurately determine phase anywhere in a matter of minutes.

Neutral Current

This is an area utilities have not spent much attention to because, prior to the availability of phase identification systems, there was no cost effective way to address it. Neutral current is caused by unbalanced phase currents and results in wasted energy. Although not possible to totally eliminate neutral currents, reducing them by using a phase identification tool to balance feeder currents throughout your system can save hundreds of thousands of dollars per year in wasted energy costs.

Page 6: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Neutral Current Loss

Page 7: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Origo PhaseID System

• No cell phones

• No work delays due to lack of cellular coverage

• Use on any voltage

• Very portable (only 3 lbs)

• Lowest cost solution available

Page 8: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Phase Measurement Comparisons

• The reference phase base station can be connected to any convenient wall socket of any phase.

• Each GPS second, the wall socket phase is measured and stored in a PC file.

• When touched to any energized line, the field probe measures the unknown phase at the next GPS second and encodes it into a 9-digit sequence.

• Base and field measurements can be compared at any convenient time and manner by simply entering the 9-digit sequence into the PC.

Page 9: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Available in Handheld or Lineman

Page 10: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Available in Manual or Datalogger

• Non-Real-Time phase attribute determination.

• Write down the phase sequences and enter them into the base station later.

• Call your dispatcher, or any other utility personnel, and give them the 9-digit sequence. They will enter it into their PC and tell you the phase attribute.

• Real-Time phase attribute determination if Internet access available.

• Automatically records the phase sequence in a measurement file.

• Provides GPS location.

• Accepts user notes.

• Real-Time Satellite communication link available soon.

Manual Version Datalogger Version

Page 11: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Lineman Field Probe

Substation Buss 12.5KV Bushing

Page 12: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Lineman Field Probe

Elbow Test Point Secondary Conductor

Page 13: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Handheld on Transmission Lines

• 345KV• No extendo stick

required.• Determine all 3

phases with a single measurement.

Page 14: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Handheld on

Overhead Lines

69KV 12.5KV

Page 15: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Handheld in Cabinets

12.5KV Bushing 12.5KV test Point

Page 16: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Handheld on Single Phase Line

Page 17: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Handheld with Netbook PC & Aircard

Page 18: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Convert a 20 Minute Extendo Stick Phasing Task on High

Overhead Lines into a 20

Second Task using the Handheld

69KV

Page 19: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Handheld on Meters

Page 20: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Three Phase Horizontal Lines

Page 21: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Three Phase Vertical Lines

Page 22: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Base Station

Page 23: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Base Station Antenna

Page 24: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Remote Base Stations

Page 25: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Base Station Software

Page 26: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Tagging Reference Phase

• Tagging reference phase is one of the most important concepts of phase identification.

• Tagging reference phase simply refers to what phase attribute you wish to call each 3-phase conductor.

• There is no universal “Phase A”. Phases A, B, and C are simply the phase attributes the utility wishes to tag or assign to each of the 3-phase conductors.

• Once assigned, all conductors of the same phase are tagged according to this chosen tagging reference phase.

Page 27: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Typical Configuration Files

Page 28: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Primary and Secondary Connection Phase Attributes

Page 29: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Secondary Phase Attribute

Page 30: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Field PC Software

Page 31: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

User Inputs

Page 32: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

GPS Position

Page 33: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

Batch Convert

• All measurement sequences can be converted to phase attribute with a single click.

• First, copy the base station daily reference file into the field PC data directory.

• Next, click on the third icon to the right of the measurement sequence window (red-to-green icon).

• This action converts all measurement sequences to phase attributes and changes all red dots to green dots.

Page 34: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

PhaseID USA Customers(That we know of)

Origo also has customers in Australia, Canada, India, Jamaica, New Zealand, and Taiwan.

Page 35: Benefits of the Origo PhaseID System. Double click on the speaker icons to hear audio.

When you are tasked with collecting thousands of

attributes to phase identify your entire utility, no other

system available is as fast and convenient as the Origo

PhaseID System