Page 1: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

BATTERY CHARGING STATION„CHARGE MANAGER 2024“

OPERATING INSTRUCTIONS FOR THE SOFTWARE

VERSION 05/15

Item no.2002024

Page 2: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

2

TABLE OF CONTENTS Page1. Functions of the „CM2024 Logger“ Software .............................................................................................................................................. 32. Installation of the „CM2024 Logger“ Software ............................................................................................................................................. 33. Getting Started ............................................................................................................................................................................................ 44. Operation of the Software ........................................................................................................................................................................... 55. Starting Charging Programmes ................................................................................................................................................................... 76. Cancelling Charging Programmes .............................................................................................................................................................. 77. Saving/Loading Recordings ........................................................................................................................................................................ 88. Use of the Windows Clipboard .................................................................................................................................................................... 89. Display Options ........................................................................................................................................................................................... 910. Operation of the Chart Function ................................................................................................................................................................ 1011. Setup „Settings“......................................................................................................................................................................................... 1212. Suspend/Contine Recordings .................................................................................................................................................................... 12

Page 3: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

3

1. FUNCTIONS OF THE „CM2024 LOGGER“ SOFTWARE• Displayoftheselectedprogramme,thecurrentprogrammesection,therechargeablebatterychemistry,thetimeandchargingparameters,

such as voltage and charging current• Recordingtheprogressofvoltage,current,charginganddischargingcapacity,etc.• Graphicalillustrationoftheprogressesofvoltageandcurrentinchartform• Printfunctionformeasuringlogs• Saving,loading,pausingandcontinuingrecordings• ExportoftherecordeddatatoExcel(fromVersion2010orhigher)includinggenerationofvoltageandcurrentcharts• ExportoftherecordeddataasCSVfile(=„CommaSeparatedValues“)forreadingintoallcommonspreadsheetprogrammes• Inputandstartofchargingprogrammes• ImportoftherecordsfromtheSDmemorycardSystem Requirements:• WindowsoperatingsystemfromWindowsXPwithSP3orhigher• NetFrameworkV4.0(ClientProfile)• Resolutionatleast1280x768

2. INSTALLATION OF THE „CM2024 LOGGER“ SOFTWAREAftertheoperatingsystemhasbeenfullyloaded,startinstallationofthesoftwareandfollowtheinstructionsoftheinstallationprogrammeoryour operating system.

Note: Beforeconnectingthe„ChargeManager2024“tothecomputer,alwaysinstallthedriversoftware(„SiliconLabsCP210xUSB-UART

Bridge“)accordingtotheinstructionsoftheinstallationprogramme. Thelatestdriverversioncanbefoundunderhttp://www.silabs.com/products/mcu/Pages/USBtoUARTBridgeVCPDrivers.aspxAftercompletionofthesoftwareanddriverinstallation,connectthe„ChargeManagerCM2024“toafreeUSBportofyourcomputerwithasuitableconnectioncable.ThechargerhasaUSBinterfaceforthis(USB-Bsocketattherearofthedevice).Windowsrecognisesthenewhardwarewhenitisconnectedforthefirsttimeandcompletestheinstallationoftherequireddrivers.IntheWindowscontrolpanel,youcancheckinthedevicemanagerwhichCOMporthasbeenawardedtothe„ChargeManager2024“(e.g.„COM7“,seearrowinthefollowingfigure).

Now software installation has been completed.

Page 4: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

4

3. GETTING STARTEDAtthefirststartofthesoftware,youneedtoselecttheCOMportofthe„ChargeManager2024“accordingtotheentryinthecontrolpanel(inthisexample„COM7“.

Thissettingcanbechangedunder„Settings/COM-Port“later.Afterconfirmingtheselectionwith„OK“,themainwindowofthesoftwareappears.

Byclickingthebutton„StartLogging“(upperleft),recordingofthedatawillbestarted(thebuttonswitchesitscolourfromredtogreenandthelabelswitchesto„stoplogging“).

Thechargermustbeinoperation,i.e.thedisplaylightingofthe„ChargeManager2024“ison.Toterminatedatarecording,clickthebuttonagain.Thecolourchangesbacktored(andthelabelofthebuttonbackto„StartLogging“,seeabove).

Ifnodataarerecordedbythechargerformorethanapprox.10secondsbecause,e.g.,theconnectiontothechargerhasbeendis-connected,theprogrammewillautomaticallyinterruptdatarecording.Continuationoftherecordingispossible.

Page 5: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

5

4. OPERATION OF THE SOFTWAREView during data recording:

1 Load,saveandimportrecordingsfromcard2 SettingtheCOM-port/displaybrightness.TerminatingtherecordingontheSDmemorycard3 ExporttoExcelor„CSV-file“4 View: Chart and/or table5 Print measuring log6 Delete recording7 Automatic display of the last measured value in the table8 Display for data reception from the charger9 Display of the recorded data in table form. The data transfer to other programmes via the clipboard is supported.10 Curves of voltage and current. Different display versions can be chosen.11 Parameterdisplayofthechargingslot.Clickingselectsthecorrespondingview.Ifthedisplayhasabluebackground,thechargepro-

grammeinputisshownafterclicking.The„Stop“symbolorright-clickcancelstherunningchargeprogramme.

1 2 43 5 6 7

8 9 10 11

Page 6: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

6

General Notes:• Therecordeddataarealwaysputininterimstorageinparalleltothedisplayinthetemporaryfilesaswell.Iftherearetemporaryfilesatprogrammestart,theprogrammeofferstocontinuetherecording.

• Whenremovingarechargeablebatteryduringtherecording,theassociatedvaluesareautomaticallydeleted.Thisensuresdataintegrity.• Theexportfunctionsfor„Excel“and„CSV“referonlytothecurrentlychosenchargingslot.• Theprintfunctionisnotavailableduringdatarecording.• Thechartsareprintedoutasshowninthesoftware.Thismeans:Ifacut-outhasbeenenlarged,theoutputtakesplaceinthisenlargedviewaswell.Insertionofatitlelineunderindicationofthebatteryslotnumber,duration,charginganddischargingcapacitytakeplaceautomatically. The recommended print format is DIN A4 or DIN A3.

• Loadingandsavingdatavia„File“->„LoadLoggedData“or„SaveLoggedData“referstothedataofallbatterychutesofthe„ChargeManager 2024“. The temporary data are overwritten in „Load Logged Data“.

• Theprogrammeensuresuninterrupteddatarecordingbydeactivatingtheenergysavingsmodeofthecomputerduringtherecording.

Page 7: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

7

5. STARTING CHARGING PROGRAMMES

Ifoneorseveralrechargeablebatteriesareinserted,theparameterdisplayshows„NoSetup“.Theparametersetupofthebatteryslotwhereprogrammeinputispossibleisdisplayedinblue.Afterclickingtheparameterdisplay,thechar-ge programme input is now displayed. The parameters suggested by the charger are displayed and can now be changed. Afterclicking„Start“,thechargingprogrammeisexecuted.

Ifthechargingprogrammeisstartedatthechargerinthemeantime,itwillbeexecutedwiththeparameterschosenatthecharger.Then the active programme input in the PC software is concealed after starting.

6. CANCELLING CHARGING PROGRAMMES

Thecurrentprogrammeofthechargingslotcanbecancelledviatherespective„stop“symbolorbyrightclickonthebatteryslotdisplayandthefinalconfirmationof„CancelProgramofSlotx“.

Page 8: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

8

7. SAVING/LOADING RECORDINGS

ThechargecurvescanbesavedontheSDmemorycardand/orthePC(„SaveLoggedData“). WhensavingonthePC,itmustbecontinuallyconnectedtothechargerandtherecording(„Logging“)mustbeactive.

IfthechargingcurveshavebeenrecordedontheSDmemorycard,thedatacanonlybereadviaacardreaderatthePCsubsequently(„ImportLogFilefromSDCard“).Itisalsopossibletoloadthesavedrecordsagainwiththissoftware(„LoadLoggedData“).

8. USE OF THE WINDOWS CLIPBOARDInadditiontotheexportfunction,thereisalsotheoptionofexportingtherecordeddataviatheWindowsclipboardintoanyspreadsheetprogrammes,suchas„LibreOffice/OpenOffice“.Procedure:1. Selecttherequiredcellsinthetable2. Right-clickingthetableshowsthefollowingdialogue: „Copy To Clipboard“ copies the selected area or „Copy All...“ copies the entire active table

into the clipboard. Alternatively,thereisalsotheoptionofsavingselecteddataby„CTRL+C“(Copy).3. Thesedatacanbedirectlytransmittedtothetargettableby„CTRL+V“(insert).

Page 9: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

9

9. DISPLAY OPTIONSUnder„DisplayStyle“,youcanselecttherequireddisplay.If„Table“isselected,onlythedataintableformareshown;whenselecting„Charts“,theillustrationofthecurvesforvoltageandcurrentingraphicformisactive.There is also the option of concurrent display of both versions.Example: Display version „Charts“

Discharge Charging Cooling pause

Final voltage

Whether charging or discharging is currently underway is shown by colour:• Greenandred:Duringthechargingphases• Darkgreenandbrown:Duringthedischargingphases• Blueandorange:Coolingphasesinthe„Maximize“programme

Missingdatapoints(e.g.duetorecordingpauses)aremarkedbygreydots.Attheendoftheprogramme,thechartalsoindicatesthefinalvoltage.

Page 10: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

10

10. OPERATION OF THE CHART FUNCTIONFunctions:Fourviewsarepossible:Line,bar,areachartandlinesin3Dperspective(„Tilt“and„Rotation“canbeset).

Line chart Bar chart

Areachart 3D-lines

Page 11: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

11

Enlarging to certain areas, „Zoom“ by mouse:Keeptheleftmousebuttonpushedinthegraphicaldisplayanddrawaframeoverthedesiredarea.Afterreleasingthemousebutton,theselected area is shown enlarged.

Alternative: Movethemousepointertotheareaofthechartandright-click.Thefollowinginputfieldappears(seefigureontheright).• „ZoomIn“enlargestheviewbyhalfoftherecording.• „ResetZoom“takesyoubacktotheoverallview.

Dependingonthepointerpositionofthemouse,youcanalsousethescrollwheeltoenlarge/reduce.

Moving the displayed areas Movementispossibleviathecursorbuttonsonthekeyboard(arrows)orthescrollbarsatthechartwindows.

Further control options via the keyboardButton Function„Home“(„Pos1“) Restoretotalview(like„ResetZoom“)„Delete“(„Entf“/„Del“) Jumptothestartoftherecording„End“(„Ende“) Jumptotheendoftherecording„“(„Backspace“) Reducezoombyonelevel„PageUp“(„Bild“) MoveX-axistowardstheendinlargesteps„PageDown“(„Bild“) MoveX-axistowardsthestartinlargesteps

Display of the data on the mouse pointer positionIfthemousepointerisplacedononeofthedisplayedcurves,pushingtherightmousebuttonwill return the current values at this time.

Page 12: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

12

11. SETUP „SETTINGS“

„COMPort“: SelectionoftheCOM-port(onlypossiblewhennorecordingisrunning)„LCDbrightness“: Settingthedisplaybrightnessofthe„ChargeManager2024“(onlypossiblewhentherecordingisrunning)„ReleaseSD-Card“: TerminaterecordingontheSD-memorycard(onlypossiblewhenarecordingisrunning)

12. SUSPEND/CONTINUE RECORDINGSAfterdisconnectingthemainsunitofthecharger,thefollowingmessagewillbedisplayedbythesoftwareafterapprox.10seconds:

Nowclosethesoftware.Ifrequired,thecomputercannowbeswitchedoff.Thesoftwarewilloffertocontinuetherecordingatthenextprogrammestart.

Youcannowtakethechargerintooperationagainandthenconfirmthesoftwaremessagewith„Yes“.Nowthelastrecordeddataareloadedand the recordings are automatically continued. Whenselecting„no“,thedataaredeletedandanewrecordingisstarted.

Ifthesoftwarehasnotbeenterminated,pushthebutton„StartLogging“aftertakingthe„ChargeManager2024“intooperation.Therecording is continued here as well.

Page 13: BATTERY CHARGING STATION „CHARGE MANAGER 2024“...By clicking the button „Start Logging“ (upper left), recording of the data will be started (the button switches its colour

( Legal NoticeThisisapublicationbyConradElectronicSE,Klaus-Conrad-Str.1,D-92240Hirschau(www.conrad.com).

Allrightsincludingtranslationreserved.Reproductionbyanymethod,e.g.photocopy,microfilming,orthecaptureinelectronicdataprocessingsystemsrequirethepriorwrittenapprovalbytheeditor.Reprinting,alsoinpart,isprohibited.Thispublicationrepresentthe technical status at the time of printing.

© Copyright 2015 by Conrad Electronic SE. V1_0515_01_DT