Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC...
Transcript of Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC...
![Page 1: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/1.jpg)
Backpanel Connector DevelopmentOctober 23, 2002
![Page 2: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/2.jpg)
� Design Objectives
� Product Design Overview
� Prototype Testing
� Project Status
![Page 3: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/3.jpg)
> Titre de la présentation - Date - Références - 3> Metral High Power – July 19, 2002 3
2mm High Power - Design Objectives
� Right angle header on daughtercard to be offered in 1x2 and 2x2 press-fit configurations (same Metral 2x2 receptacle to be used for both)
� FCI will also tool a Millipacs 2x2 receptacle in early 2003. This will mate with the same 2mm headers (1x2 and 2x2) as the Metralversion.
� Same press-fit hole size as Metral (0.65-0.80 finished hole diameter)
� Current carrying capacity (single 12mm module, all lines powered):
� 2x2 configuration: 72A (18A per line); verified by pre-production product
� 1x2 configuration: 80A (40A per line); not yet verified
![Page 4: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/4.jpg)
> Titre de la présentation - Date - Références - 4> Metral High Power – July 19, 2002 4
2mm High Power - Design Objectives
� Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances)
� Receptacle is UL 60950 compliant (Finger Probe)
� 3 possible mating lengths (2 longest being tooled initially) equal to those of Standard Metral 8.0, 6.5, and 5.0mm header pins; mating length is controlled on the receptacle side
� Same module size as 5-row Standard/1000/2000 Metral (10.8mm press height)
� All footprint hole spacing is on even multiples of 2mm
![Page 5: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/5.jpg)
> Titre de la présentation - Date - Références - 5> Metral High Power – July 19, 2002 5
2mm High Power - Product Design Overview
� All contacts are flat except for minimal forming on the header’s mating interface
� Because minimal forming is necessary, less formable / higher conductivity materials may be used
� Air is able to access a large percentage of header contact surfaces. This will allow heat to escape more easily.
� Air is able to flow through the fully mated system
� EON is the same geometry as used in Metral Converged Headers
� FCI patent filed on May 23
![Page 6: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/6.jpg)
> Titre de la présentation - Date - Références - 6> Metral High Power – July 19, 2002 6
2mm High Power - 2x2 header
air flow passages
![Page 7: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/7.jpg)
> Titre de la présentation - Date - Références - 7> Metral High Power – July 19, 2002 7
2x2 header top and bottom contacts
![Page 8: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/8.jpg)
> Titre de la présentation - Date - Références - 8> Metral High Power – July 19, 2002 8
2mm High Power - 1x2 header
air flow passages
![Page 9: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/9.jpg)
> Titre de la présentation - Date - Références - 9> Metral High Power – July 19, 2002 9
1x2 header contact
![Page 10: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/10.jpg)
> Titre de la présentation - Date - Références - 10> Metral High Power – July 19, 2002 10
2mm High Power - Metral 2x2 receptacle
air flow passages
![Page 11: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/11.jpg)
> Titre de la présentation - Date - Références - 11> Metral High Power – July 19, 2002 11
Metral 2x2 receptacle contacts
![Page 12: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/12.jpg)
> Titre de la présentation - Date - Références - 12> Metral High Power – July 19, 2002 12
2x2 contact system, Metral version
![Page 13: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/13.jpg)
> Titre de la présentation - Date - Références - 13> Metral High Power – July 19, 2002 13
1x2 contact system, Metral version
![Page 14: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/14.jpg)
> Titre de la présentation - Date - Références - 14> Metral High Power – July 19, 2002 14
2mm High Power, Metral 2x2 version -Beside Metral 1000 (fully mated)
![Page 15: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/15.jpg)
> Titre de la présentation - Date - Références - 15> Metral High Power – July 19, 2002 15
2mm High Power - Prototype Testing
� Prototype assemblies were made using
SLA housings and wire EDM & gold plated
STB-style terminals
� Test boards were designed following
practices commonly used for PwrBlade
products
� 2.4mm thick boards
� Double-sided 5 oz. & double-sided 2 oz.
copper traces were tested
� Temperature rise vs. Applied current
measured at 12 thermocouple locations
(6 on contacts near mating areas and 6
on nearby PCB traces)
![Page 16: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/16.jpg)
> Titre de la présentation - Date - Références - 16> Metral High Power – July 19, 2002 16
2mm High Power - Prototype Testing
Double-sided 5oz. copper traces
![Page 17: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/17.jpg)
> Titre de la présentation - Date - Références - 17> Metral High Power – July 19, 2002 17
2mm High Power - Prototype Testing
Double-sided 2oz. copper traces
![Page 18: Backpanel Connector Development October 23, 2002 · Voltage rating: 150 V per UL 60950 and IEC 664-1 & 61984 specifications (1.6mm minimum creepage and clearance distances) Receptacle](https://reader034.fdocuments.in/reader034/viewer/2022050116/5f4d6183f9b77f29830daf18/html5/thumbnails/18.jpg)
> Titre de la présentation - Date - Références - 18> Metral High Power – July 19, 2002 18
2mm High Power, Metral version -Project Status
� PACE Phase 0 (Concept) review: completed March 8, 2002
� PACE Phase 1 (Product Development) review: completed April 12, 2002
� Capital expenditures for tooling: approved May 23, 2002
� PACE Phase 2 (Process Development) review: completed June 19, 2002
� PACE Phase 3 review (Pre-Production release): October 15, 2002
� PACE Phase 4 complete (Qualified Production available): March, 2003