AWS310 SITE applications using ICAO- and WMO-compliant ......• ICAO- and WMO-compliant sensors...
Transcript of AWS310 SITE applications using ICAO- and WMO-compliant ......• ICAO- and WMO-compliant sensors...
Automatic Weather StationAWS310‑SITE
Features
• Designed and tested for aviationapplications with Vaisala AviMetâ
systems
• Complete solution for weatherdata collection
• Wide range of installation, powersupply, and communicationoptions
• ICAO- and WMO-compliantsensors with long calibrationintervals
• Surge protection for power input,sensor connections, and outputdata connections
Optimized for Airport WeatherObservation NeedsAWS310‑SITE is specially designed andtested for Vaisala AviMet AutomatedWeather Observing System (AWOS) andLow‑level Windshear Alert System(LLWAS), ensuring complete end‑to‑endsystem integration. With Vaisala AviMet,users are able to collect and viewweather data remotely, as well asmonitor and control the AWS310‑SITEobservation stations.
A Complete SolutionThe AWS310‑SITE solution includeseverything required for accurate andreliable weather measurements: theenclosure, a wide variety of sensoroptions, installation kits, power supply,and communication devices.
The solution has a robust, tightly sealedIP66 stainless steel (AISI 316) enclosureto protect the electronics. AWS310‑SITEis available with different installation andpowering options according to customerneeds and site requirements, including asolar-powered option for remotelocations.
The AWS Client software is included formaintenance purposes to support setup,diagnostics, and data retrieval.
Data CollectionMeteorological data is sent to the airportweather observation system in real time.There are several standardcommunication options available,including landline communicationthrough RS‑232, RS‑485, or leased-linemodem, or wireless communicationthrough a UHF/VHF radio interface.
To provide redundancy in safety-criticalairport applications, data can be sentsimultaneously via 2 parallelcommunication ports. The data is alsosaved on the weather station’s externalmemory card. The stored log files can beexported to external applications.
Excellent Long-term StabilitySensor calibration is vital to accurate andreliable observations. The sensors ofAWS310‑SITE ensure excellent long-termstability with a low risk of drift or suddenchanges in calibration. This results inlonger calibration intervals, lowermaintenance costs, and reduceddowntime.
Installation OptionsThere are several standard masts andmast installation kits available forAWS310‑SITE. Frangible options includepole masts DKE110F, DKP721, and DKP711and lattice mast DKE200. Vaisalafrangible masts are impact-tested, andthey comply with the frangibilityrequirements set in the followingspecifications:
• ICAO Doc 9157 Aerodrome DesignManual, Part 6 Frangibility, FirstEdition, 2006
• FAA AC 150/5345‑45C – Low ImpactResistant Structures, 2007
Standard Safety FeaturesAWS310‑SITE includes surge protectionfor the power input, sensor connections,and output data connections. Surgearrestors protect the AWS310‑SITE unitfrom potential damage caused by pooror variable power quality, or otherpossible surges.
Vaisala Automatic Weather Station AWS310‑SITE is anautomatic weather station that is optimized for airportweather observations. Based on the proven VaisalaAWS310 weather station, AWS310‑SITE provides reliableand accurate weather measurements for aviationapplications using ICAO- and WMO-compliant sensors.
Technical Data
Operating EnvironmentOperating temperature −40 ... +60 °C (−40 ... +140 °F) 1)
Storage temperature −60 ... +70 °C (−76 ... +158 °F) 2)
Operating humidity 0 ... 100 % RH
1) For internal battery storage and operating temperature range, see manufacturer documentation.2) Excluding HMP155.
Environmental Compliance
Test Applied Standardor Test Procedure
Specification
Operation
Dry heat IEC 60068-2-2 +60 °C (+140 °F)
Cold IEC 60068-2-1 −40 °C (−40 °F)
Damp heat IEC 60068-2-30 +40 °C (+104 °F) / 85 ... 95 %RH
Vibration IEC 60068-2-6 0.7 g (0.025 oz) 10 ... 200 Hz2 ... 9 Hz to 200 Hz, 1.5 mm(0.06 in) displacement
Shock IEC 60068-2-27 5.0 g (0.18 oz)Pulse duration 11 ms with100 pulses in each direction
Storage
Dry heat IEC 60068-2-2 +80 °C (+176 °F)
Cold IEC 60068-2-1 −60 °C (−76 °F)
Damp heat IEC 60068-2-30 +40 °C (+104 °F) / 85 ... 95 %RH
Transport
Vibration (random) IEC 60068-2-64 Random
Rough handling IEC 600068-2-31 Drop height 60 cm (23.62 in)
EMC Compliance
Test Applied Standardor Test Procedure
Specification
Electrostatic discharge EN 61000-4-2 4 kV contact, 8 kV air
Fast transient burst EN 61000-4-4 2 kV AC, 1 kV I/O, and DC
RF field immunity(80 MHz ... 6 GHz)
EN 61000-4-3 11 V/m (80 MHz ... 1 GHz)4 V/m (1 GHz ... 2 GHz)2 V/m (2 GHz ... 6 GHz)
Conducted RFimmunity
EN 61000-4-6 4 V e.m.f. (150 kHz ... 80 MHz)
Immunity to voltagedips and shortinterrupts
IEC 61000-4-11 0 % 1 cycle40 % 10 cycles70 % 25 cycles0 % 250 cycles
Powering SpecificationsAC (mains) power 100 ... 240 VAC, 50 ... 60 Hz
5.6 A maximum (120 VAC)
External power 15.5 ... 30 VDC6 A maximum
Internal backup battery 12 V / 26 Ah or 12 V / 52 Ah
Mains fuse (nominal) 10 A minimum
Solar panel 70 W
BOX652 SpecificationsIP rating IP66
Material Stainless steel AISI 316, painted white
Size (enclosure only) 600 × 500 × 207 mm(23.62 × 19.68 × 8.15 in)
Weight Approximately 30 kg (66 lb)
Maximum wind speed 75 m/s (168 mph)
Standard Sensor OptionsWind speed and direction WMT700, WA15 (dual sensors
available)
Air temperature and relative humidity HMP155
Barometric pressure PTB330 (Class A accuracy, with3 transducers)
Global solar radiation SMP3, SMP6, SMP10
Sunshine duration CSD3
Rain/Precipitation RG13(H), OTT Pluvio2 L
Runway temperature DRS511
Runway temperature and surface state RWCC
Ground temperature QMT107
Soil temperature QMT110
Standard interface CL31, LT31, FS11, FS11P, PWD22,TSS928
Standard Communication OptionsLandline communication RS‑232, RS‑485, or leased-line
modem
Wireless communication UHF/VHF radio interface
Fiber optic communication With Vaisala Field CommunicationBox FOC201 or customer-providedsolution
Dual communication Any combination of 2 standardcommunication options
Standard Accessories2 enclosure locks
USB maintenance cable
2 removable 2 GB CF memory cards
Optional AccessoriesObelux Obstruction Light QOL111
Vaisala TERMBOX‑1200 for mains power and 1 data line
Vaisala TERMBOX‑1212 for mains power and 2 data lines
Vaisala Fixed Display QMD202 inside the enclosure
Installation kits for:• 100 mm (3.94 in) pole mast (DKP210)• 106 mm (4.17 in) frangible pole mast (DKE110F, DKP721, DKP711)• Frangible lattice mast (DKE200)
Published by Vaisala | B211652EN-B © Vaisala 2018
All rights reserved. Any logos and/or product names are trademarks ofVaisala or its individual partners. Any reproduction, transfer, distributionor storage of information contained in this document is strictlyprohibited. All specifications — technical included — are subject tochange without notice.www.vaisala.com