Automated Unidirectional Flushing Software Programs Proven Technology or Vaporware?

39
www.msa-ep.com Automated Unidirectional Flushing Software Programs Proven Technology or Vaporware? 1 Presented by: David Stangel, P.E. [email protected] Murray, Smith & Associates, Inc.

description

Automated Unidirectional Flushing Software Programs Proven Technology or Vaporware?. Presented by: David Stangel, P.E. [email protected] Murray, Smith & Associates, Inc. Engineer as a Designer of the Human Body. - PowerPoint PPT Presentation

Transcript of Automated Unidirectional Flushing Software Programs Proven Technology or Vaporware?

Page 1: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Automated Unidirectional Flushing Software ProgramsProven Technology or Vaporware?

1

Presented by:

David Stangel, [email protected]

Murray, Smith & Associates, Inc.

Page 2: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Engineer as a Designer of the Human Body

Three engineering students were gathered together discussing the possible designers of the human body.

One said, ``It was a mechanical engineer. Just look at all the joints.''

Another said, ``No, it was an electrical engineer. The nervous systems has many thousands of electrical connections.''

The last said, ``Actually it was a civil engineer. Who else would run a toxic waste pipeline through a recreational area?”

2

Page 3: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

What is Unidirectional Flushing or UDF?

The sequential closing of system valves and

opening of hydrants to obtain adequate pipe

velocities to flush debris, dirty/discolored water

from the system

3

Page 4: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

How is it Different than Traditional Flushing Methods?

Additional planning is required Identification of flushing areas using hard copy maps Typically aided by a hydraulic model to identify valve/hydrant

sequence and simulate velocities and discharge rates

Targets velocities of 5 ft/s (min 3 ft/s) Traditional flushing doesn’t guarantee adequate

velocities Normally positive redundancy and looping works against

flushing

Traditional flushing may drop system pressure below 20 psi

Traditional flushing may involve all hydrants UDF only flushes strategically placed hydrants

4

Page 5: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

UDF Compared with Traditional Flushing

5

Flushed Hydrant

Closed Valves

Flushed Hydrant

Page 6: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Why Flush? (other than for obvious personal reasons)

Maintains distribution system water quality Restores disinfectant residual

Reduces disinfectant demand

Reduces bacterial growth

Dislodges biofilms

Removes sediments and deposits

Restores flows and pressures

Eliminates taste and odor problems

6

Page 7: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Why Flush?

Other reasons for UDF Increases general system understanding for staff

– Integrates new staff

Identifies missing/broken valves/hydrants

Leverages hydraulic model/GIS investment

Uses less water than traditional techniques (up to 40%)

Corrosion control

7

Page 8: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Keys to an Effective UDF Program

Plan, plan, plan

Quality maps with pertinent information for field crews

Operations staff input Incorporate parts of existing flushing programs where

possible

Public notification

Yearly or bi-yearly flushing schedule

8

Page 9: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

What Information is Required to Develop a UDF Plan?

Hydraulic model Requires a calibrated model

Steady state or extended period mode

Hydrant/valve GIS layers CAD information can be utilized if available Assumptions for locations can be made if layers don’t exist

Firm understanding of system operation

9

Page 10: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

UDF Software

Recent releases by software vendors suggest that developing a UDF plan using their tools is an easy next step.

Should we believe it?

10

Page 11: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

UDF Software cont.

It is relatively straightforward with completely clean data in exactly the required format.

We all know how often that is the case.

11

Page 12: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Available Tools

MWH Soft & Bentley Systems

MWH Soft UDF - separate module

Requires InfoWater (ArcGIS) license

Bentley Includes UDF with all platforms

(stand alone, CAD, ArcGIS)

12

Page 13: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Available Tools

Pricing dependent on number of pipes Example List Prices for 5000 pipe model

Bentley – WaterGEMS $12k + cost of AV MWH Soft - InfoWater $8k + UDF $7k + cost of AV

MWH Soft Valves and hydrant laterals do not increase pipe count

Pipes are not split

Bentley Requires a split where hydrants intersect pipes

Laterals must be entered

No split for valves

13

Page 14: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Approaches to UDF

MWH Soft UDF focus

– Can automatically close all valves along pipe alignment

Bentley Starts with conventional flushing

Progresses to UDF

– Valves open as default

– User closes

14

Page 15: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

UDF Model Building Process

Add valves/hydrantsWas the model created from GIS?

Valves/hydrants to be operated should be provided

QA/QC

– Are hydrant and valve numbers populated and unique?

– Valves○ Does layer “register” with model?

– Hydrants○ Number of ports and size○ Elevations

– Hydrant laterals○ Length and diameter

15

Page 16: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

UDF Model Building Process

Valves & Hydrants are key for building the UDF database

16

Page 17: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Hydrants

Pertinent attributes associated with hydrant

Requires preprocessing “Pipe” attributes not normally

associated with hydrants

– Length, roughness, diameter

Non-hydraulic information can be tracked

17

Page 18: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Hydrants

Auto-associated to model pipes in InfoWater UDF Auto-calcs mainline

distance

Hydrants can be associated “mid-pipe”

Must be “built” into Bentley’s network Includes splits at hydrant

laterals

18

Generated by InfoWater UDF

Page 19: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Valves

Ensure correct valve/pipe association

Auto-associated InfoWater UDF

Bentley

Non-hydraulic information can be tracked

19

Page 20: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Valve Registration

What we want to see

20

Making our life interesting

Page 21: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Registration Issues

Valve registration can be critical If the user wants to use valve ids for closing in the field

21

Page 22: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Model Tools

Many InfoWater QA/QC and data building tools are unavailable in UDF Unique valve/hydrant identifiers

Hydrant elevation interpolation

Association of lateral attributes to hydrants

– Lateral length and diameter

Visual check for valve associations

General editing of valve/hydrant databases

Cannot fully leverage Domain Manager in UDF

22

Page 23: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Model Tools cont.

In general the Bentley flushing tools are integrated into the modeling platform

Biggest limitation is the requirement for building hydrants and laterals into the model database

– Adds pipes to model increasing price

– Adds unneeded complexity for most modeling procedures

23

Page 24: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

UDF Model Building

Don’t underestimate the effort

Can be significant depending on input data quality Particularly if the model has not been created from GIS

When old data is put to a new use, previously unknown “issues” arise Plan for it

24

Page 25: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

UDF Analysis Criteria

Typical flushing velocity Min 3 ft/s

Target 5 ft/s

Shear stress criteria can be used in InfoWater

Min system pressure typically 20 psi

25

Page 26: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Analysis Process

Using large format system map: Mark up flush zones

– Typically pressure zones or smaller

– Each zone associated with a “primary” source

– Each zone includes a number of flush sequences

– Work from source to system periphery

26

Page 27: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Analysis Process

In the model: Identify initial flush pipeline(s)

Identify what hydrant(s) will be opened

Identify valves to be closed

– Take care not to isolate portions of the system from water

– Minimize valve closures○ Labor intensive for field crews

27

Page 28: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Example InfoWater UDF Flushing Sequence

28

Sequence 1Sequence 2

Sequence 3Sequence 4

Page 29: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Tabular InfoWater UDF Output

29

Page 30: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

What Does the Field Crew Use?

They need to know: What system sources should be operating

What valves should be closed and when they should be reopened

– Identify valve number and/or street intersection

What hydrants should be opened

– Identify hydrant number

– Identify flow to target

– Identify how long to run hydrant

They need a series of maps clearly showing the sequences and associated information

30

Page 31: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

What is Currently Availablefor Field Maps?

31

Page 32: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Field Maps

Bentley does not offer field map template

Utilities are turning to in house or consulted ArcGIS programming to develop field maps

Some utilities want maps in the same format as their standard field books

32

Page 33: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

So What Should You Do?

Software vendors focus on “first to release” rather than the product’s “polish” Positive

– Vendors willing to work with users to enhance products

Negative

– Enhancement turnaround time can be slow due to large number of software packages supported

What level of usability and beta testing should users expect?

– Price dependant

33

Page 34: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Who Should Purchase these Tools?

Developing a flushing program Not like modeling tools that are used regularly

Takes an initial focused effort

No need to redo on a weekly/monthly basis

– unless growing rapidly

If utilities use Bentley then they already own it Otherwise:

– Utilities – No

– Consultants – Yes

34

Page 35: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Additional Development

Primary areas for further development InfoWater UDF

– Model building and QA/QC

– Field map customization capability

Bentley

– Associate hydrants without permanent pipe splits

– A field map generator

35

Page 36: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Future Enhancements

MWH Soft Committed to more than 20 enhancements

More incentive

– UDF module sold separately

Bentley Open to suggestions for enhancements

Less incentive

– Included in modeling suite

36

Page 37: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Summary

UDF Ensures adequate flushing velocities are being achieved Can reduce the number of hydrants operated Can reduce the amount of flushed water used Can reduce the frequency of required flushing

– Does a more effective job of removing debris, biofilm and dirty water

Provides a target flow rate for flushing

– Should minimize unnecessary low pressures

37

Page 38: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

Summary cont.

AWWA and industry supports UDF plan development beyond traditional flushing

Software tools will be more valuable/usable once additional enhancements have been made

If a utility has: Invested in a hydraulic model

Accurate valve/hydrant information

they can develop a UDF plan with reasonable effort

38

Page 39: Automated Unidirectional  Flushing Software Programs Proven Technology or Vaporware?

www.msa-ep.com

So Flush Away!

Special Thanks to: Sammamish Plateau Water and Sewer District

City of Redmond, Oregon

Matt Caldwell, Bentley Systems

Erick Heath, MWH Soft

Questions?

[email protected]

39