PERMACONN PM35 v3 Install Manual Australia Radio Data Comms Unit 5/20 - 30 Stubbs Street Silverwater NSW 2128 Australia Telephone: 0508 897 897 Facsimile: 0508 896 896

Transcript of Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to...

Page 1: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

PERMACONN PM35 v3

Install Manual Australia

Radio Data Comms

Unit 5/20 - 30 Stubbs Street

Silverwater NSW 2128

Australia

Telephone: 0508 897 897

Facsimile: 0508 896 896

Page 2: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 2

Introduction / Features of the PM35v3 ...........................................................3

Data Plans / Atlas Web Platform......................................................................4

Installation Procedure.................................................................................... 4-5

Programming the Alarm Panel...........................................................................5

Powered from Alarm Panel / Defaulting the PM35v3........................................6

Outputs...............................................................................................................7

Inputs / PM35 v3 LED Status Indicators........................................................... 8

Securitel Interface............................................................................................. 9

How to change the IP & Port Numbers if Required....................................10-13

Contact ID Reporting Codes............................................................................13

PM35 v3 Specifications / Liability....................................................................14

Introduction

Table of Contents

Page 3: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 3

The Permaconn system provides two-way communication between supervised premises and the

Control Room. The PM35v3 is a versatile state of the art microprocessor based IP security communicator. This unit can interface with a range of alarm panels using RS232 and Contact ID.

Three (3) Inputs

Three (3) Outputs

Contact ID interface

High level serial Interface

The IP Module acquires an IP address automatically using the customers DHCP service

Serial interface to Cardax, C&K, Concept, Tecom, MCM and Siemens

IP reporting

Monitors and reports status of Alarm Panel interface lead

Monitors and reports DC power status

Non-volatile memory stores all setup information in the event of a power failure

Various LED status indicators for easy onsite diagnostics

Supervisory Period

IP (only)

1 Hour P6

Features of the Permaconn PM35v3

Data Plans

Atlas is a secure web portal that enables users to activate and interrogate their Permaconn IP communicators remotely for diagnostic and control purposes. This portal can be accessed via the web using any Smartphone, Tablet or PC. We strongly recommend using this application to verify your install. Apply online www.permaconn.com

Atlas Web Platform

Page 4: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 4

Before applying power, the communicator must be activated using the Atlas „App‟ on your

Smartphone, PC or Tablet. This communicator will not operate unless it has been correctly activated.

Apply 10 - 14.5DC to the power terminals. Power is normally obtained from the Alarm Panel. If you are using an independent power supply make sure that you have a common negative.

The „HB‟ LED will blink

Connect CAT5 cable between the PM35 and the local router or network point

The PM35 will automatically obtain an IP address - If it is set to DHCP

Connection to the internet indicated by „IP‟ LED „Green steady on‟

A four wire connection is required between the alarm panel and the PM35v3. Ring & Tip as input and R1 & T1 as the return line.

Program the alarm panel- Contact ID, Tone Dialling, account number, and an 8 digit telephone number.

Generate an event from the alarm panel.

Test input and output.

Ping the device with Atlas to verify status of installation.

Always use the original telephone lead supplied with the alarm panel – between the alarm panel and the PM35v3.

A four wire connection is required between the Alarm Panel dialler and the PM35. „Ring‟ & „Tip‟ as the input and „R1‟ & „T1‟ as the return line. If the return line is not connected the „CID‟ LED will be [Red - On] indicating a fault. This lead is also used to monitor the interconnectivity between the Alarm Panel dialler and the PM35. If the dialler lead is removed a „Dialler Lead Interface Fail‟ event will be sent to the Monitoring Centre. This will indicate that the panel has lost connectivity with the PM35.

Connect a CAT5 cable between the PM35v3 and the local router or network point. Power cycle the PM35v3 after connecting the cable. Ports 55572 & 59680 UDP must be opened in the client‟s firewall / router for successful IP communication.

PM35v3 will automatically obtain an IP address if it is set to DHCP (default).

Installation Procedure

Page 5: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 5

Connection to the internet is indicated by the „IP‟ LED = [Green – Steady On].

A four wire connection is required between the Alarm Panel dialler and the PM35v3.

Use a dour core cable between PM35v3 and alarm panel dialler terminals.

„R‟ & „T‟ as the input and „R1‟ & „T1‟ as the return line. If the return line is not connected the „CID‟ LED = [Red - On] indicating a fault. This lead is also used to monitor the interconnectivity between the Alarm Panel dialler and the PM35v3.

The PM35v3 obtains the Panel ID directly from the Alarm Panel after the first valid contact ID event is sent.

If a fixed Panel ID is required - inform the Control Room before activation.

The Alarm Panel must be programmed with: o Contact ID o Tone / DTMF dialling o Four digit Panel ID number o 8 digit telephone number o Arm & Disarm reporting must be enabled. (This is required for the Pocket Secure App)

Trigger an alarm event or test report from the alarm panel. The panel dialler will seize the line and send data on „R‟ & „T‟. „CID‟ LED = [Green - Blinking].

When a valid Contact ID event is sent from the alarm panel the „CID‟ LED = [Green - Steady On].

Ping the PM35v3 using Atlas to verify status of installation.

Installation Procedure continued...

PM35v3 Testing from Alarm Panel

Programming the Alarm Panel

Page 6: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 6

Apply DC power and depress reset button for:

o Ten (10) seconds to reset IP configuration.

(Caution if using Static IP this will revert back to DHCP).

o LEDS will all flash together for four (4) seconds to confirm successful default.

Defaulting the PM35v3

PM35v3 Powered from Alarm Panel

Page 7: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 7

There are three (3) outputs available.

Outputs are „Open Collector‟ @50mA switching negative - for heavier loads a relay must be used.

Ensure there is a common negative between PM35v3 and the device being switched.

The outputs can be Opened, Closed or Pulsed remotely using the Permaconn Atlas web portal. ( Only Pulse is available when using Pocket Secure App)

Refer to technical addendums for detailed key switch information. Compatible with „Pocket Secure‟ remote control „App‟, available now on Apple, Google Play and Windows stores.

NB: Arm & Disarm reporting must be enabled in your Alarm Panel if using Pocket Secure

Wiring Diagram for key switch connection Example shown as a typical keyswitch connection refer to each manual for correct procedure. A common –ve must be in place between the alarm system and the PM35v3.

Typical set up for following panels:

o Ademco series o C & K series o NX series o Bosch 2000/3000 o Ness D8 / D16 o DSC

Outputs

Page 8: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 8

Inputs

There are three (3) inputs available.

Inputs are programmed as 24 hour instant zones.

Inputs only need to be terminated with a 3K3 resistor if used.

Do not terminate with EOL resistors if not used.

Wiring Diagram for inputs

Input CID Part Zone

Aux 1 140 0 981

Aux 2 140 0 982

Aux 3 140 0 983

PM35v3 LED Status Indicators *Normal Operation

Page 9: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 9

„Serial‟ MUST be selected on activation otherwise it will not operate.

The PM35v3 comes standard with Securitel / serial interfaces for: o Tecom o MCM Icon o C&K o Siemens o Cardax / Gallagher (IFM-CDX required) o Concept (10K resistor must be fitted between terminals +12v & Rx)

CID LED [Green - Blink] to indicate successful Securitel or serial interface. Wiring Diagram for Serial Connection

Serial Interface

PM35 v3 LED Status Indicators

LED Activity Indication

CID

OFF No first time Data

Red Dialler lead fail

Orange Event captured Dialler lead fail

Green * Event captured Dialler OK

Green Flashing Data transfer

IP

Green * Internet Connection

Green Flashing Router Connection „NO‟ Internet

OFF No Router Connection

HB Green On * CPU OK

OFF CPU not OK

* Normal Operation

Page 10: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 10

Additional Wiring for Concept STU Connection

Panel Client Software (PCS) is a virtual modem application that enables remote access to the alarm panels using a hardwired Ethernet connection.

Note: Disable fax machine defeat and call back. Enable one (1) call to answer.

Tecom V8 & V10 Titan v3.02+/ Forcefield v6.4+

NX4 / 16 / 128 Reliance DL900 v4.01+

DL150 / 250 / 300 DL900 v4.01+

Solution 844 / 16 / 880 A-Link Plus v4.12+

Solution 16i / 16 Plus / 64 Solution Link v1.2.3+

Solution 6000 Solution Link v2.1.1+

DSC PC4020 / PC1616 DLS2002

DSC PC1616 + PC1864 DLS-5 (v4.2)

Crow Runner 8 / 16 ULD16 (v2.0.0.1+)

Paradox MG-5050 & EVO-192 Winload (v5.50+)

Ness D8 NessComms (v5.6.0.0+)

Ness M1 Gold ElkRP v2.0.24

Risco LightSYS Config Software (v2.1+)

MCM Icon8 MCM Connect v5.45

Concept 3000 & 4000 Insight Installer (v5.4.10) & Wdirect 6.0+

Digiflex Vision 16 / 64 Vision Link

Protege' LE Protege' SE

How to change the IP & Port Numbers *Static IP only

3

Upload / Download (Using Permaconn IP)

Page 11: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 11

Creating a Static IP address

Before you start you need the following:

Laptop

Network cable

Permaconn IP setup program (available from www.permaconn.com). To connect to the PM35v3:

Connect the PM35v3 to the PC (or in the same LAN with standard Ethernet cable).

Run the program “IpSetup.exe”

Enter the serial number of the unit and press connect

Default the Permaconn unit and wait until the screen is populated with the current values.

Important, the PM35v3 will only attempt to connect to the setup program after a default.

To change values, simply modify the fields and select „write‟. When the PM35v3 is switched on it initialises with the default settings, so a large percentage of installations should work right away. You only need to modify the setup for special local requirements.

All settings below are also available through the Atlas web portal if the PM35v3 has Connectivity

How to change the IP & Port Numbers *Static IP only...continued...

3

Page 12: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 12

Obtain IP address automatically (DHCP) If ticked, DHCP is enabled and the unit will obtain the IP Address, IP Mask and the Gate Way automatically. Otherwise you must enter these values yourself. Please note that these values must be correct for the clients LAN that you connect the PM35v3 to. Use DNS below If this is ticked, you must enter valid IP addresses that point to the available domain name servers. If not ticked, it is filled in by the DHCP service of the LAN. Note that a DNS is only required if you are using a domain name for the primary and/or secondary server addresses. Local Port [55300] in UDP You can use any port above 10000, not critical.

Remote Port [55300] in UDP

This must match the „listen‟ port of the Permaconn server, the default should be correct for your country. If in doubt, confirm with Radio Data Comms. This port is vital - if incorrect the unit will not be able to connect.

Download Port [59680] in UDP

This is set by default and you must not change this port, it is not vital for communicating with the server during normal operations.

How to change the IP & Port Numbers ...continued...

3

Page 13: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 13

MAC Address This is set by default and is unique for each unit. It should only be changed if the instructed by the IT department responsible for that network. Primary and Secondary Server Connection This is also set by default and is correct for your location. This is also a vital setting and must be correct; otherwise the unit will not be able to connect. If in doubt, check with Radio Data Comms. This field can be either an IP address or a domain name. You only need to modify the setup for Static IP networks, if this is required un-tick the DHCP box and enter the required settings then select [Update]. When the PM35v3 is switched on it initialises with the default settings, so a large percentage of installations should communicate on IP immediately.

Access to Atlas portal.

Connect the PM35v3 to the LAN with standard Ethernet cable.

The PM35v3 must be online and can be pinged using Atlas.

Primary and Secondary Server Connection

This is also set by default and is correct for your location. This is also a vital setting and must be correct; otherwise the unit will not be able to connect. This field can be either an IP address or a domain name. Primary Server: 105.255.153.83, Backup Server: 196.31.49.73.

How to change the IP & Port Numbers ...continued...

3

Page 14: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 14

Upload / Download Connection

If the PM35v3 has an IP connection and Upload / Download functionality is required ensure that port 55533 UDP is not blocked.

Messages originating from the Alarm Panel are forwarded immediately.

Alarm Panel „Dialler Interface Lead Fail‟ is sent if not restored within 90 seconds.

INSTA

LLATION MUST BE CARRIED OUT BY SERVICE PERSONNEL ONLY

THE EARTHING TERMINAL ON THE DIALLER MODULE MUST BE PERMANENTLY CONNECTED TO EARTH.

Event ID

Partition Zone Description

313 0 954 Engineering Reset (changed encryption key) – No action required.

337 0 950 Expansion Module DC Loss – 13.8V DC voltage low or absent.

350 0 953 Fail To Communicate – Communicator experienced trouble sending signals do not expect restore.

352 0 956 Dialer Interface Lead Fail – Issue with dialer lead between Permaconn communicator and the Alarm Panel.

356 0 968 Permaconn Communicator - IP path poll fail.

356 0 970 Permaconn Communicator – Communicator is offline.

140 0 981 Auxiliary 1 – Auxiliary input alarm on communicator.

140 0 982 Auxiliary 2 – Auxiliary input alarm on communicator.

140 0 983 Auxiliary 3 – Auxiliary input alarm on communicator.

Transmission Delay Times

Contact ID Reporting Codes

Liability

Page 15: Aus Permaconn PM35 v3 (v3)_IP... · PM35v3 will automatically obtain an IP address if it is set to DHCP (default). ... o Cardax / Gallagher ... Permaconn PM35 v3 Aus September 2017

Permaconn PM35 v3 Aus September 2017 Version 1.0 RDC_2011_E_IN 15

PM35v3 Specifications

The socket-outlet must be installed near the equipment and easily accessible.

Telephone plugs and connectors must be installed inside the metal enclosure of the unit. Interconnecting cables must be placed in conduit.

The unit must be installed in accordance with this manual for proper operation.

Standards require regular service by qualified and licensed technicians and regular testing.

Housing Material ABS plastic – white

Dimensions 110mm (h) x 25mm (d) x 80mm (w)

Weight 120g

Operating Environment 0° - 50° @ 15% to 85% humidity (non condensing)

Data Modem 14400 baud modem for upload / download

Power 10 – 15V DC. Terminal or plug pack socket available

Power Consumption PM35: Standby: 0.05A @13.8V DC

Communication Protocol Ethernet (10/100BASE-T)

Network Protocol DHCP or Static IP

Serial Port High Speed RS232 interface

Auxiliary Input 3 x 24Hr inputs – state change detected every second EOL 3.3K

Auxiliary Output 3 x Open Collector outputs @ 50mA (max) Function control using Atlas web portal and/or „Pocket Secure‟

Static IP Network Ethernet interface using „IpSetup‟ program

Approvals EN301489, EN301908, EN62311, EN60950-1