12 Volt Air Conditioner | 12 Volt Air Conditioner Reviews | 12 Volt Air Conditioner for Cars
Argo Air Conditioner 2012
-
Upload
argoclima-spa -
Category
Documents
-
view
291 -
download
15
description
Transcript of Argo Air Conditioner 2012
www.argoclima.com
The company, our products and
our reference markets
Argoclima S.p.A. specialises in the supply of products and services for the air conditioning, heating and air treatment market. Our range of products are almost all designed and manufactured in the Argoclima factories (in Italy and France), they provide state-of-the-art solutions that stand out for their advanced technology, design and modular nature. These features allow all manner of problems to be quickly resolved and offer excellent solutions with top energy efficiency performance.In addition to the products normally on offer through retail channels (portable and wall-mounted air conditioning systems, dehumidifiers and supplementary heating), our company also offers a range of ARGO brand products. These include direct expansion air-conditioning systems ranging from 2.2 to 150 kW with COP levels of above 5.Segmentation by heat output allows for the quick and easy identification, differentiation and positioning of the range of products, which focus on applications ranging from private homes to office buildings and from small and medium-sized retail outlets to shopping centres... The direct expansion systems all make use of Full DC Inverter technology to create systems with many dozens of indoor units, with over 300 metres of piping and height differences between units of over 50 metres.
Condensing units and terminal units, designed using the most advanced design and manufacturing techniques, they work brilliantly within a wide range of outdoor temperatures from -20°C to +43°C. Their mechanical properties facilitate handling and installation, thus reducing the cost of building systems. They can also be controlled using the most advanced building control systems (CIB/BMS), via local, centralised and/or remote controllers with web and fieldbus interfaces (lonworks...).
Organisation
and services
Argoclima S.p.A. is specifically organised to best support the needs of various types of customers: the needs of Retail customers, for example, are sometimes similar and sometimes very different to those of Installation Technicians, Wholesalers and B2B operators. Private consumers can also find answers to their questions both via conventional means and services as well as via new computer technologies: our website, www.argoclima.com, provides a large amount of information at different levels of expertise and access in order to satisfy any type of request. An extensive network of After-Sales Service Centres and the European Spare-Parts Centre guarantee a high level of After-Sales Service. The After-Sales Service Centres are linked-up via Internet to specific web applications used to manage the various phases of scheduled or corrective maintenance operations. In order to meet the particular needs of installers who specialise in the sale of centralised systems, Argoclima S.p.A. offers a full-range of services through a well-structured organisation which reports to the Systems Division:
designer;
specific context/system design as a whole;
adapting to new technologies.
In order to provide the above-mentioned services, Argoclima S.p.A. has a team of qualified technicians and sales personnel, who receive regular training on technological and regulatory matters.Argoclima S.p.A.’s logistics centre is located near the town of Brescia and manages the entire logistics process for incoming and outgoing goods for customers throughout Europe and beyond.Argoclima S.p.A. has been in the marketplace for 80 years, a level of experience that provides absolute assurance of the company’s capacity for Innovation, Quality and Service in the manufacture of the finest Italian-made products.
iSERIESTM, a multi-functional integrated system
iSERIESTM is the commercial name for the HVAC system (heating, ventilation and air conditioner) manufactured by Argoclima S.p.A.; it comprises of a series of components that allow the creation of mono and multi-split systems, in air/air, air/water and mixed air/air plus air/water configurations, with or without the generation of domestic hot water and combination with thermal and photovoltaic solar systems.
4 www.argoclima.com
A complete system, not just a simple split unit…
is a system based entirely onrenewable energy sources, designed to provide heat even in Nordic areas in installations operating in outside temperatures as low as 30 degrees below zero, and to provide cool air in desert regions in installations operating at over 50 degrees, multifunctional and highly energy efficient.
offers truly integrated applications for comfort, scalability, expandability and modularity;multi-processor electronics control the 180 SVPWM DC Inverter, which modulates the heat energy according to real needs, from a minimum of 10% up to a maximum of 130% of nominal output.
is conceived, designed and built entirely in Italy, in the Argoclima laboratories and main factory in Gallarate in the province of Varese, 40 Km north of Milan and only 5 Km from the international airport of Milan Malpensa.
I SE
RIE
SI
SE
RIE
S
5www.argoclima.com
is a split system with a feature that has never been seen before: the same outdoor units are both mono and multi, they do not change based on the application and are compatible with all the indoor units in the iSERIESTM range. From 2012 six outdoor units will be available to satisfy the needs of the most demanding customers, covering a modulated heat output range from 0.6 kW to over 13 kW; the range will be further extended up to over 22 kW.
AEI1G30 AEI1G40 AEI1G50 AEI1G65 AEI1G80 AEI1G110*
Outdoor units
HEATINGCOOLING
*available in 2012
I S
ERRR
IS
ERRRR
IES
IES
Indoor units
6 www.argoclima.com
The indoor units in the iSERIESTM range are divided into categories by heat output and by application.
There are four heat output categories:- size A for heat output up to 4 kW
- size B for heat output up to 7 kW
- size C for heat output up to 11 kW
- size D for heat output up to 14 kW
Thanks to the iSERIESTM sophisticated inverter regulation system, the classic references of rated power outputs are replaced by a greater flexibility and the number of product codes and references is reduced by 70%.
WALL FLOORCEILING
FLOOR SLIMDUCTED
CASSETTE DUCTED HYDROKIT
The application categories are:
Air/Air type:
Air/Water type:
wall mounted two-way floor mounted floor mounted - reversible for ceiling mounting
Hydrokit for floor-mounted systems, radiators and fan coils
floor mounted - reversible for recessed ceiling mounting (slim ducted) cassette for false ceilings mono and multi-zone ductable
Domestic hot water
R410A
H2O
All indoor units can be connected individually or used in combination with other units, based on thermal balance criteria aimed at creating an integrated system that fully satisfies the requirements of the end customer.
MIXED AIR/AIR + AIR/WATER APPLICATIONI S
ER
IES
IS
ER
IES
Applications
is a primary and integrated system for heating, air conditioning, air treatment and domestic hot water production, entirely based on a sophisticated technique employing high efficiency inverter heat pumps, a renewable energy source that can be combined with thermal and photovoltaic solar power.
The flexibility of the iSERIESTM system satisfies the requirements of the residential market and small service sector applications: from the most simple high quality split unit systems to multi-zone systems with floor-mounted systems, to multi-split systems for apartments, offices and public spaces...
7www.argoclima.com
Great flexibility in the combination of different types and categories of indoor units allows many different applications to be realised that before required the use of different systems that were difficult to integrate with one another.
Below is a summary of possible applications that should give installation technicians an idea of the wide range of possibilities offered by the iSERIESTM system:
Air/air mono-split, from a typical high quality residential split unit system to solutions for small service sector applications, offices, restaurants, bars... also multi-zone systems with ductable units... or for special applications such as containers, motor homes...
Air/water mono-split, this solution is commonly used for heating and cooling with floor mounted systems, but can also be used with low temperature radiators or fan coils, even in combined and multi-zone combinations.
Air/air multi-split, a classic solution for the summer air conditioning of apartments and villas but also for heating and cooling offices, shops and small service sector applications in general.
Air/water multi-split mixed with air/air, an unusual solution that offers a extremely wide spectrum of applications. With this system we can create a floor mounted system with two zones and at the same time air condition a cellar and loft conversion with an air/air unit suited to these spaces: wall mounted, floor mounted with two-way flow or maybe even ductable.
I S
ER
IS
ER
IES
IES
8 www.argoclima.com
Outdoor units
Technical specifications for outdoor units
Refrigerant flow/volume regulation via centralised PID control system acting on a vectorial inverter and electronic expansion valves.
SVPWM180°, vectorial inverter with sensor less 180° PWM; this is a purely sinusoidal inverter with extremely low electromagnetic noise emissions. It provides constant control of the permanent magnet synchronous motors throughout their 360° revolution (180°+180°). This optimises torque, a key factor in motor control for compressors in particular, thus providing excellent performance in terms of output, efficiency and quietness, especially at low rotational speeds.
Multi-processor platform based on the client/server model, with an operating system controlling the motors and microprocessors dedicated to application management fitted in the outdoor and indoor units.
Standard RS485 bus communication via screened bi-polar cable: the highest level of communication security is ensured thanks to a balanced interface normally used for industrial applications. The bus provides an address for each unit and can be wired either as a bus or in a star configuration starting from the outdoor unit. This allows the system to be expanded and developed whilst still ensuring compatibility between units. One advantage of the RS485 bus is the possibility of supplying the units in the system with power either in a centralised manner or each to unit independently.
The range of outdoor operating temperatures is very wide; regulations require full operation from -15°C to +43°C but the iSERIESTM exceeds this: we have heat pump installations working at up to -30°C in Nordic areas and cooling installations in desert regions operating in outside temperatures of over 50°C. The iSERIESTM control system is able to protect itself and implements operational shut down only when the temperature reaches -50°C, practically absurd conditions for a heat pump.
I SE
RIE
SI
SE
RIE
S
9www.argoclima.com
Compressor Liquid ice prevention; a dedicated heater coil, controlled by the electronics and software in the outdoor unit controller, cuts in to prevent the compressor Liquid from freezing when the system is inactive in stand by and outdoor temperatures require it.
Ice prevention at the base of the outdoor unit; a dedicated electric heater coil is fitted indoor the metal base of the outdoor unit and is activated by the software when temperature conditions require in order to prevent the formation of ice.
Non Stop Operation and Intelligent Defrost; the prevention and elimination of ice on the heat exchanger in the outdoor unit is an essential process for an air-condensed heat pump. Thanks to its special control algorithms, iSERIESTM carries out this task in an intelligent way and, unless strictly necessary, without inverting the refrigerating cycle and therefore with a continuous (albeit reduced) heat supply to the heated area.
Compact and sophisticated electronics, built using SMD technology, resin coated for protection from atmospheric
agents and equipped with certified hardware protection circuits.
Diagnostic system for the easy identification of any technical faults, with data logging for technicians accessed directly from bus RS485.
BootLoader for software updates for outdoor and indoor units, with no risk of losing flash eprom data.
Automatic restart following power black outs, with the same operating parameters as before and restart protected against excess pressure.
Heat exchangers in high quality copper/
aluminium with inorganic hydrophilic
aluminium, which does not emit odours and provides top performance in heat exchange output and efficiency.
Maximum installation flexibility, thanks to the specifications governing pipe length and height difference between units.
Rust-proof treatment, providing the best protection against corrosion and rust formation even under extreme conditions such as in saline mist.
I S
ER
IS
ER
IES
IES
AEI1G30, the smallest outdoor unit in the iSERIESTM range, designed for mono-split applications but not only for hiwall and not only for air/air applications (EMIXTM).AEI1G30 is very compact, its heat output is nearly 4 kW and it is built to withstand the worst atmospheric conditions without corrosion. It has a plastic front grille resistant to UV rays covering the entire surface and a silver logo with the brand and a Made in Italy logo. The elegant pipe cover completes the unit, which is one of the most compact and quiet available on the market.
AEI1G40 and 50 are built using the same chassis for mono/dual solutions up to 6 kW.Its size provides high performance whilst still remaining quite compact. Corrosion resistant metals prepared for the worst atmospheric conditions and plastics resistant to UV rays complete these particularly quiet outdoor units.
10 www.argoclima.com
AEI1G65, despite its heat rating of over 8.5 kW, this unit is compact, strong and quiet. Like the other units in the iSERIESTM range, this unit is designed to withstand the worst conditions. It can be used for mono, dual and triple solutions with a wide range of air and/or water indoor units.
AEI1G80, mono, dual, triple and quadruple configurations in a single outdoor unit compatible with all the multifunction indoor units in the iSERIESTM range, and with a heat output of up to 11 kW. Corrosion resistant metals impervious to saline mist, UV ray resistant plastic and concealed pipe attachments complete this excellent and quiet unit.
AEI1G110*, over 13 kW in a compact chassis with a single fan, for mono, dual, triple and quadruple applications with high heat outputs, this unit is suitable for fully integrated primary solutions for heating and cooling offices and family homes. Corrosion resistant metals impervious to saline mist and UV ray resistant plastic; a top-of-the-range outdoor unit, quiet and flexible with an excellent heat output.
*available in 2012
I SE
RIE
SI
SE
RIE
S
11www.argoclima.com
Technical Data
Outdoor units
The technical data provided refers to European Standard EN14511, as per Directive 2002/31/CEN.B. Provisional data used at the time of printing
AEI1G30Specifications Units Cooling Heating
Capacity nominal (min-max) kW 2,65 (1,37-3,6) 2,75 (0,93-3,32)
Energy class ABCDEFG A A
E.E.R. / C.O.P. (kW/kW) 3,96 4,82
Fan speed N° self modulating
Sound pressure O.U. (max.) dB(A) 40
Electrical power supply V/Ph/Hz 230/1/50
Power input kW 0,67 0,57
Annual energy consumption (500h)-Dir. 2002/31/EC kWh 335 -
Compressor type Single Rotary
Refrigerant type R410A
Liquid pipe diameter mm (inch") 6,35(1/4”)
Gas pipe diameter mm (inch") 9,52(3/8”)
Length of pipes (with standard charge) m 7,5
Length of pipes (with additional charge) m 15
Maximum height difference IU/OU (outdoor unit above or below) m 10
Net weight Kg 35
Net dimensions (H./W./D.) mm 540x700x265
AEI1G40Specifications Units Cooling Heating
Capacity nominal (min-max) kW 3,50 (1,25-4,25) 3,90 (1,20-5,20)
Energy class ABCDEFG A A
Nominal E.E.R. / C.O.P. (kW/kW) 3,68 4,19
Fan speed N° self modulating
Sound pressure O.U. (max.) dB(A) 44
Electrical power supply V/Ph/Hz 230/1/50
Power input kW 0,950 0,930
Annual energy consumption (500h)-Dir. 2002/31/EC kWh 475 -
Compressor type Rotary
Refrigerant type R410A
Liquid pipe diameter mm (inch") 6,35(1/4”)
Gas pipe diameter mm (inch") 9,52(3/8”)
Length of pipes (with standard charge) m 15
Length of pipes (with additional charge) m 15 (no additional charge)
Maximum height difference (outdoor unit above) m 7
Maximum height difference (indoor unit above) m 7
Net weight Kg 39
Net dimensions (H./W./D.) mm 630x895x345
I S
ER
IS
ER
IES
IES
Technical Data
12 www.argoclima.com
The technical data provided refers to European Standard EN14511, as per Directive 2002/31/CEN.B. Provisional data used at the time of printing
AEI1G50BSpecifications Units Cooling Heating
Capacity nominal (min-max) kW 4,55 (0,84-5,18) 5,19 (0,95-6,00)
Energy class ABCDEFG A A
E.E.R. / C.O.P. nominal value (min.-max.) (kW/kW) 3,35 (4,20-2,93) 4,29 (5,94-3,43)
Fan speed N° self modulating
Sound pressure O.U. (max.) dB(A) 41
Electrical power supply V/Ph/Hz 230/1/50
Power input nominal (min-max) kW 1,360 (0,200-1,770) 1,210 (0,160-1,750)
Annual energy consumption (500h)-Dir. 2002/31/EC kWh 680 -
Compressor type Twin Rotary
Refrigerant type R410A
Liquid pipe diameter mm (inch") 6,35(1/4”)
Gas pipe diameter mm (inch") 9,52(3/8”)
Length of pipes (with standard charge) m 15 tot. Dual / 7.5 Mono
Length of pipes (with additional charge) m 30 tot. Dual / 20 Mono
Length of pipes per unit (with standard charge) m 12 (Dual)
Length of pipes per unit (with additional charge) m 25 (Dual)
Maximum height difference IU/OU (outdoor unit above or below) m 20 tot. (max. 10m I.U.)
Net weight Kg 56,5
Net dimensions (H./W./D.) mm 630x895x345
AEI1G65Specifications Units Cooling Heating
Capacity nominal (min-max) kW 6,50 (1,57-8,71) 7,30 ( 1,82-8,67)
Energy class ABCDEFG A A
E.E.R. / C.O.P. nominal value (min.-max.) (kW/kW) 3,25 (3,78-3,00) 4,32 (5,05-3,82)
Fan speed N° self modulating
Sound pressure O.U. (max.) dB(A) 40
Electrical power supply V/Ph/Hz 230/1/50
Power input nominal (min-max) kW 2,0 (0,415-2,90) 1,69 (0,36-2,27)
Annual energy consumption (500h)-Dir. 2002/31/EC kWh 1000 -
Compressor type Twin Rotary
Refrigerant type R410A
Liquid pipe diameter mm (“) 6,35(1/4”)
Gas pipe diameter mm (“) 9,52(3/8”) / 12,77(1/2”)
Length of pipes (with standard charge) m 30 tot. Dual-Triple / 20 mono
Length of pipes (with additional charge) m 45 tot. Dual-Triple / 35 mono
Length of pipes per unit (with standard charge) m 25 (Dual) 20 (Triple)
Length of pipes per unit (with additional charge) m 30 (Dual) 25 (Triple)
Maximum height difference IU/OU (outdoor unit above or below) m 10 tot. Dual-Triple / 10 mono
Net weight Kg 64
Net dimensions (H./W./D.) mm 735 x 1030 x 400
AEI1G80Specifications Units Cooling Heating
Capacity nominal (min-max) kW 8,15 (1,60-9,62) 9,21 ( 1,70-11,20)
Energy class ABCDEFG A A
Nominal E.E.R. / C.O.P. (kW/kW) 3,70 4,22
Fan speed N° self modulating
Sound pressure dB(A) 47
Electrical power supply V/Ph/Hz 230/1/50
Power input kW 2,20 2,18
Annual energy consumption (500h)-Dir. 2002/31/EC kWh 1100 -
Compressor type Twin Rotary
Refrigerant type R410A
Liquid pipe diameter mm (“) 6,35(1/4”)
Gas pipe diameter mm (“) 3 x 9.52 (3/8”) / 1 x 12.77 (1/2”)
Length of pipes (with standard charge) m 30 tot.
Length of pipes (with additional charge) m 65 tot. multi / 50 mono
Length of pipes per unit (with standard charge) m 30
Length of pipes per unit (with additional charge) m 50
Maximum height difference IU/OU (outdoor unit above or below) m 30 tot. multi / max. 10 per unit
Net weight Kg 73
Net dimensions (H./W./D.) mm 835x1190x400
I SE
RIE
SI
SE
RIE
S
13www.argoclima.com
Combinations
APPLICATIONS
AIR / AIR COMBINATIONS
AIR/ WATER COMBINATIONS
*Connect to ports A and B inserting the integrated accumulator using the bypass provided with AEI1G65
AEI1G 30 AEI1G 40 AEI1G 50B AEI1G 65 AEI1G 80 Air/Air X X X X X
Air/Water X X X
Air/Air and Air/Water X X X
AEI1G 30 AEI1G 40 AEI1G 50B AEI1G 65 AEI1G 80
Mono A A B B B
Mono C C
Dual A+A A+A* A+A
Dual A+B A+B A+B
Dual B+B A+C
Dual B+B
Triple A+A+A A+A+A
Triple A+A+B A+A+B
Triple A+B+B
Quadruple A+A+A+A
Quadruple A+A+A+B
AEI1G 50B AEI1G 65 AEI1G 80
HKBE HKBE HKCE
AEI1G 30 AEI1G 40 AEI1G 50B AEI1G 65 AEI1G 80
Wall AWIA S8 W/B mono mono
Wall AWIA S87 W/B mono multi multi multi
Wall AWIA S7F mono multi multi multi
Floor AFIA S11 mono mono multi multi multi
Floor/Ceiling FCIA S8 mono mono multi multi multi
Floor/Ceiling-recess SDIA S8 mono mono multi multi multi
Cassette ASIA S8 mono mono multi multi multi
Wall AWIB S9 mono/multi mono/multi mono/multi
Floor AFIB S11 mono/multi mono/multi mono/multi
Floor/Ceiling FCIB S9 mono/multi mono/multi mono/multi
Floor/Ceiling-recess SDIB S9 mono/multi mono/multi mono/multi
Cassette ASIB S9 mono/multi mono/multi mono/multi
Hydraulic module HK BE mono mono/multi
Ducted ADIC S10 mono mono mono/multi
Cassette ASIC S10 mono mono/multi
Hydraulic module HK CE mono/multi
SIZE A
SIZE B
SIZE C
I S
ER
IS
ER
IES
IES
(Ln) Individual lengths
(L) Individual lengths
14 www.argoclima.com
AEI 1G 30/40
L
AEI 1G 50
L1
L
L2
L
L
AEI 1G 65
AEI 1G 80
L1
L1
L2
L2
L3
L3
L4
Maximum pipe lengths and maximum distances
between outdoor unit and indoor units
The AEI1G50 outdoor unit, equipped with a standard charge of refrigerant (preloaded in the factory), allows for a maximum pipe length of 7.5 metres in mono configuration and up to 15 metres in dual configuration. By adding refrigerant (20 grams per metre in mono configuration and 15 grams per metre in dual configuration), the maximum length is extended to 20 metres in mono configuration and 30 metres in dual configuration.In the event of dual configurations it should be remembered that each of the two indoor units can be positioned at a different distance from the outdoor unit. If the maximum distance of the first indoor unit from the outdoor unit is 12 metres, the second indoor unit must be placed at a maximum distance of 3 metres from the outdoor unit. This is because the maximum pipe length (15 metres), must never be exceeded. Of course in the event of additional refrigerant, the maximum distance of the first indoor unit can be up to 25 metres, and the second, 5 metres.Similar concepts can also be applied to outdoor units AEI1G65 and AEI1G80, and the same shall apply for future outdoor units in the iSeries range.The table below combined with the diagram allows you to easily identify the maximum values for the pipe lengths / maximum distances between outdoor and indoor units.
Height differences between outdoor and indoor
units and between indoor units
The maximum height difference between the outdoor unit and indoor unit/s does not depend on the distances and/or the pipe lengths described above. It depends instead on the total height difference between the various units (both outdoor and indoor) that make up the split or multi-split system.In multi-split configurations there is also a relationship between the maximum height difference between the outdoor unit and indoor units (sum of height differences). For example, if the total maximum height difference between the outdoor unit and indoor units as declared by the manufacturer is 10 metres and the maximum height difference between the two indoor units is 5 metres, in a dual configuration with the outdoor unit on the ground floor, the first indoor unit can be installed at up to 7 metres above (or below), but the second unit may only be fitted a maximum of 3 metres above (or below). This is so as not to exceed 10 metres (7+3 = 10) and at the same time to not exceed the 5 metres of maximum height difference between the two indoor units (7-3 = 4).On the other hand, it is not possible to position the first indoor unit at 8 metres and the other at 1 metre from the outdoor unit. This is because even though the sum of height differences is less than the maximum height difference of 10 metres (8+1 = 9), the height difference between the two indoor units would however reach 7 metres, exceeding the maximum permitted height difference. Where the same dual configuration outdoor unit is positioned at a height in between the two indoor units, the first indoor unit can also be installed one metre below the outdoor unit. In this case the second indoor unit can be installed at a maximum of 4 metres above the outdoor unit because the maximum height difference of 5 metres between indoor units cannot be exceeded. With this type of installation the two indoor units are in fact usually placed at a height difference of 2.5 metres with respect to the outdoor unit.
Standard charge Additional charge
Outdoor unit Configuration Tot L Max L Tot L Max L
AEI1G30 mono-split 15 - 15 -
AEI1G40 mono-split 15 - 15 -
AEI1G50B mono-split 7,5 - 20 -
AEI1G50B dual-split 15 12 30 25
AEI1G65
mono-split 20 - 35 -
dual-split 30 25 45 30
triple-split 30 20 45 25
AEI1G80
mono-split 30 - 50 -
dual-split 40 30 65 30
triple-split 40 30 65 30
quadruple-split 40 30 65 30
Tot L = total length of pipes, given by the sum of pipe lengths for each indoor unitMax L = maximum pipe length per single indoor unit, whether it is no. 1, 2, 3….
Maximum height difference (sum of height differences)AEI1G30 and AEI1G40 = 7 m
AEI1G50 = 20 m
AEI1G65 = 30 m
AEI1G80 = 40 m
Maximum height difference between two indoor units (only for multi-split systems)AEI1G50 = 5 m
AEI1G65 = 5 m
AEI1G80 = 5 m
I SE
RIE
SI
SE
RIE
S
Indoor units
15www.argoclima.com
Technical specifications for indoor units
Every indoor unit in the iSERIESTM system has its own specific features but there are also features common to all units in the range, these are listed here below.
Dynamic Cold Draft, an active protection system preventing the emission of air that is noticeably colder than ambient temperature during heating operation and particularly during defrost stages.
Antifreeze, this protection system prevents the formation of ice on the indoor unit heat exchanger when the system is working in cooling mode and there are particular temperature and humidity conditions.
Temperature settings from +10°C to +32°C both in cooling and heating modes; the units can therefore be used for indoor low ambient temperature applications such as in cellars, server rooms and radio stations... They can also be used to maintain a minimum temperature in spaces that are unused during weekends such as offices and shops, or places that are unused during the week such as holiday homes in the mountains or at the seaside...
iFEEL function, a comparative function that ensures optimum temperature settings based on the values read at the remote control sensor, the sensor in the indoor unit and the resulting ambient temperature stratification conditions, which are always different from one room to another.
Wide range IR receiver, this receives the remote control signal even under difficult conditions. It is equipped with a noise canceller for complete immunity from interference generated by low energy consumption fluorescent bulbs.
Hardware or software addressing of units for recognition on communication bus RS485.
Remote control addressing for the management of one or more grouped indoor units, up to a maximum of four units. This function is useful where several indoor units are situated in a large space (open space offices, hotel reception rooms, restaurants, etc...), and need to be controlled either by one or several remote controls.
I S
ER
IS
ER
IES
IES
16 www.argoclima.com
Five operating modes: automatic, cool, heat, dehumidify and fan.
Night Function for maximum operating economy during the night without compromising comfort.
High Power Function, when maximum power is required straight away.
Active/passive air filters: all air/air units are equipped with washable mesh filters and can be fitted with an activated charcoal filter; some units are fitted as standard with a titanium dioxide photocatalytic anti-bacterial filter, activated via remote control by invisible dedicated LEDs fitted indoor the unit, fully compliant with EU regulations concerning UV emissions.
Intelligent air flap control based on operating mode, which when combined with the iFEEL function offers the maximum in comfort to counter air temperature stratification effects.
Automatic fan (or manual fan) to provide maximum heat (when required) and the right amount of cool, without creating annoying cold air draughts or excessive amounts of hot air.
Timer for programming the operating times of each individual indoor unit, with weekend* and holiday* controls.
Wireless and wired universal remote control for all iSERIESTM indoor units, with multi-function keypad, LCD graphic display, wall mount and wired* connection.
Elegant ergonomic interface with discreet micro LEDs that can be deactivated via remote control, particularly useful for those that prefer complete darkness at night.
Protective grilles, which offer the maximum in safety in compliance with standard EN60335. This allows for installation even at low heights where children could otherwise potentially touch moving parts such as fans and motors.
* this last function is available with the new remote control for 2012
I SE
RIE
SI
SE
RIE
S
17www.argoclima.com
Heat exchangers in high quality copper/aluminium with inorganic hydrophilic aluminium, which does not emit odours and provides top performance in heat exchange output and efficiency.
Plastic materials with high quality looks and functional properties (improved thermal stability). As green as possible thanks to the use of noble acrylics such as PMMA, pure ABS for the parts on view and recycled PS for the internal structures.
Hydrokit with heat exchanger with plates made from AISI316L stainless steel for heat exchange between the refrigerant and water, built-in module for additional electrical heating, automatically controlled by software in three steps, controlled by thermal-magnetic switches that can be deactivated manually, safety thermostats, pressure switch, high performance water pump and water flow rate control device.
Controller for hydrokit , with climatic curve control and control of the various applications of the hydronic circuit (floor, fan coils, radiators, mixed...), with the possibility of separation into areas with different settings.
Wide range of hydronic accessories to suit various different system configurations.
Generation of domestic hot water using the EMIXTM module, the internal unit for the iSERIESTM system, which is able to provide hot water from a thermo-dynamic source all year round. EMIXTM will become available in 2012 and will have its own illustrated manual explaining the functions and operating modes in connection with the iSERIESTM system.
I S
ER
IS
ER
IES
IES
18 www.argoclima.com
A8, a wall-mounted indoor unit with a distinctive design, ideal for modern spaces
and also compatible with more conventional styles. Combines easily with many
different styles and colours found in the office and at home.
I SE
RIE
SI
SE
RIE
S
19www.argoclima.com
very quiet:
only 21 dB(A)Heat exchanger in odourless inorganic
hydrophilic aluminium
This filter uses the oxidising power of Titanium Dioxide (TiO
2) to destroy bacteria and inhibit viruses. It also
effectively reduces dust and dirt particles and helps to prevent unpleasant odours.
Organic compounds, odours, bacteria, viruses...
A8 is designed to provide high energy efficiency and has one very important feature: it can be recess fitted using the dedicated wall mounting kit.
84 mm
The front panel made from PMMA, a prized acrylic material, is dual coated on the back and available in satin white or carbon fibre black; the transparent border along the panel perimeter creates a bright frame that responds to colour changes in the environment. The horizontal central strip in silver conceals the noiseless remote control signal receiver and the extremely elegant blue and white micro LEDs. These are very discreet and can also be deactivated using a function developed specifically for those that prefer complete darkness at night.
A8 is also easy to install, thanks to the possibility of being able to connect the refrigerant pipes either to the horizontal compartment or to the right side; the bilateral condensation discharge pipe and the possibility of fitting the unit at below two metres in height (thanks to the protection grille), complete the flexibility of this high quality indoor unit.
A8 is available in size A, and at 21 dB(A) is extremely quiet. The unit is equipped with an active photocatalytic filter, which is able to significantly reduce the bacterial load in the environment thanks to the titanium dioxide oxidation process activated by completely concealed special UV LEDs that are fully compliant with EU standards.
Titanium Dioxide filters and Air QualityI
SE
RI
SE
RIE
SIE
S
20 www.argoclima.com
Elegant and discreet, available in sizes A (A7) and B (A9), an indoor unit to suit
all tastes, suitable for all settings both in terms of design and heat output.
I SE
RIE
SI
SE
RIE
S
21www.argoclima.com
The optional activated charcoal filter is comprised of a layer of synthetic material folded to increase the filtering surface area and treated with a professional anti-bacterial solution, combined with an activated charcoal mesh. Activated charcoal is a material mainly made up of carbon in the form of graphite micro crystals treated in such a way as to create a porous structure with a vast internal surface area. When the forced air flow passes through the filter element, the charge of static energy allows the filter to trap even the smallest particles of pollutants and allergens, down to a size of 0.01 microns. The activated charcoal layer attracts and absorbs the organic molecules responsible for unpleasant odours, eliminating them completely.
The casing for model A7/A9 is treated using a photo engraving technique to obtain a satin effect on the plastic, this is done during the injection stage and no further treatments are applied. You can see the quality of the material and manufacturing process used with the naked eye, this sets the A7/A9 unit apart from other white wall-mounted indoor units.
A7/A9 allows condensation discharge to the right or left, it has LEDs that can be deactivated and washable filters, it is compact and easy to install.
very quiet: only 23 dB(A)Heat exchanger in odourless inorganic hydrophilic aluminium
Mesh filters with optional odour-capturing activated charcoal filter I
SE
RI
SE
RIE
SIE
S
22 www.argoclima.com
A refined console for low wall installation, at just a few centimetres from the floor and
with two-way air flow, up and down, for maximum comfort in summer and winter.
I SE
RIE
SI
SE
RIE
S
23www.argoclima.com
AF is very sophisticated, it is equipped with a DC motor (DCM), and in stand by consumes only 70 mW. It is equipped with a humidity sensor that is used to differentiate the use of the two air flows based on the sensed temperature index.
AF is available in sizes A and B, whilst still maintaining the same structure and dimensions. It filters and purifies the air using a washable mesh filter and a titanium dioxide photocatalytic filter that can be activated via remote control. At 22 dB(A), the unit is extremely quiet thanks to its specially-designed structure and two tangential fans managed by inverter-controlled DC motors.
AF is the newest model and is also the first in its class within the iSERIESTM range of indoor units. Compact and made from pure ABS, it is well suited for installation under windows or mid-wall, occupying the smallest space possible.
LED operation can be deactivated by remote control
LED operation can be deactivated by remote control
very quiet: only 22 dB(A)
I S
ER
IS
ER
IES
IES
24 www.argoclima.com
FC and SD, two versions of the same unit, reversible for floor or ceiling instal-
lation, they can be fitted on view (FC) or concealed in dedicated spaces (SD)
created using plasterboard or wood or in false ceilings.
I SE
RIE
SI
SE
RIE
S
25www.argoclima.com
very quiet:
only 24 dB(A)Heat exchanger in odourless inorganic
hydrophilic aluminium
Easy installation and condensation discharge
Easy maintenance
Ceiling installation
LED operation can be deactivated by remote control
Condensation anti-drip system
Fits anywhere!!!
ONLY
18.9 cm!!!
Vertical installation
FC and SD are available in sizes A and B, whilst still maintaining the same structure and dimensions. They are easy to install and maintain thanks to washable filters that are easy to access on both versions. SD, despite being designed for recessed and therefore concealed fitting, can be controlled by the iSERIESTM universal remote control in either wireless or wired mode.
The depth of only 19 cm and quiet operation at 24 dB(A), make these two iSERIESTM units an excellent solution for villas, offices, hotel rooms, restaurants and public spaces etc.
I S
ER
IS
ER
IES
IES
AS, the cassette unit for false ceilings that we can often observe above our heads
in public spaces, offices, shops and restaurants.
It is certainly also suitable for private dwellings as it was originally designed with
this application in mind, however it is more common to see it used in service
sector applications.
It is certainly also suitable for private dwellings as it was originally designed with
this application in mind, however it is more common to see it used in service
sector applications.
26 www.argoclima.com
I SE
RIE
SI
SE
RIE
S
27www.argoclima.com
Easy installation and discharge
Perfect integration!
Body in anti-corrosion metal Simple and convenient maintenance
Flocked anti-condensation flaps
very quiet:
only 35 dB(A)Heat exchanger in odourless inorganic
hydrophilic aluminium
As with all the other units in the iSERIESTM range, AS is controlled using the universal remote control. In the contexts in which this cassette unit is installed the remote control is able to express some of its more special features, such as the option for wired connection instead of wireless control and the ability to control groups of units, which is very useful for open space offices, restaurants, and hotel reception areas.
Available in sizes A and B, and with slightly larger dimensions (80x80) also in size C, this unit is built with great attention to detail: insulated metal, four flocked anti-condensation flaps, carefully calibrated fan, quality plastic grille and a large filter that is easy to access for cleaning.AS is designed for air exchange with the outside, which is mandatory for installations in public spaces, and is equipped with a condensation discharge pump.
ASIA/ASIB ASIC
I S
ER
IS
ER
IES
IES
28 www.argoclima.com
AD, the high prevalence ductable unit, to be combined with purpose built plenums
with or without the aid of the three-way duct built into the unit.
I SE
RIE
SI
SE
RIE
S
29www.argoclima.com
AD, as with the cassette units, this unit is mainly designed for use in service sector applications and is built with great care from carefully selected materials.
Available in size C, it is equipped with high quality centrifugal fans and a condensation discharge pump. It is also fitted with washable filters that are easy to access and can be controlled using the iSERIESTM universal remote control in wired or wireless mode.
Plenum for channelling the air into 3 spaces
Perfect distribution
Removable filters
Standard integration
I S
ER
IS
ER
IES
IES
30 www.argoclima.com
The iSERIESTM system is able to control air-condensed indoor units simultaneously with Hydrokit to create a mixed air/water and air/air system. The wide range of possibilities for use both as a mixed system and as a conventional split inverter air/water heat pump system, should be very interesting to installation technicians who will discover the unique versatility of the iSERIESTM system.
Hydrokit, installed indoor the building as if it were a wall-mounted boiler, is equipped with high quality plate heat exchangers made from AISI316L stainless steel, a high efficiency water pump and a module for additional electrical heating with three power steps (2+2+2 kW). The system is fully controlled by the unit’s software according to heat requirements but can also be manually deactivated using the dedicated thermal-magnetic switches. A pressure gauge displays the water pressure in the circuit and there are also safety pressure switches and a device that controls the water flow rate.
Hydrokit HKE, available in sizes B and C, is the indoor unit to be combined with
the iSERIESTM outdoor units to create heating and air conditioning solutions
with floor, wall or ceiling mounted radiator systems.
I SE
RIE
SI
SE
RIE
S
31www.argoclima.com
EMIXTM is the innovative indoor unit in the iSERIESTM range, able to provide domestic hot
water from a thermo-dynamic source all year round, i.e. independently of the system’s
operating mode.
EMIXTM works simultaneously with the other units in the system, both in air/air and air/water configurations or in mixed air/air and air/water combinations, an absolute first.
EMIXTM will become available in 2012 and will have its own illustrated operating manual demonstrating the possible combinations with other indoor units and connection configurations with outdoor units in the iSERIESTM range.
In addition to mixed air/water and air/air configurations, unique to the iSERIESTM system, Hydrokit is also able to control many hydronic applications:
heating and air conditioning with mono and multi-zone floor, wall or ceiling mounted radiator systems;heating using low temperature radiators, also in combination with floor mounted radiator systems;air conditioning using hydronic terminal units or fan coils, also in combination with floor mounted radiator systems.
It should be remembered that the installation of air/air indoor units in the same area as a floor mounted radiator system avoids the need to install dehumidifiers for the cooling cycles and accelerates arrival at the desired set point in both heating and cooling modes.
Hydrokit is provided with an area controller, a sensor to be fitted on the building exterior and a water filter. The controller manages both the climatic curve and the entire hydronic system; it can be connected to other similar controllers to manage separate areas with the aid of the multi-zone module. Other accessories for the hydronic system are available on request to satisfy special requirements.
I S
ER
IS
ER
IES
IES
All air conditioner operating parameters can be controlled from the remote control:
operating modes (auto or cooling only, heat pump only, dehumidification only,
fan only), 1h and 24h timer, desired temperature, ambient temperature reading,
TiO2
filter activation (where fitted), fan speed, flap oscillation for optimum air
distribution in the room and economy or night functions. Many operations can
be set automatically or managed when needed, including the deactivation of the
LED indicators for those that prefer complete darkness at night.
Universal Digital Remote Control
be set automatically or managed when needed, including the deactivation of the
LED indicators for those that prefer complete darkness at night.
I SE
RIE
SI
SE
RIE
S
32 www.argoclima.com
Wide display with graphic symbols and alphanumeric indicators.
Built-in temperature sensor.
Dual transmitter
Wide range of operation. The presence of a dual infrared transmitter
ensures a very wide range of operation: just place the remote control
where you like for “made-to-measure” comfort in that area.
iFeel function
a comparative function that ensures optimum temperature settings
based on the values read at the remote control sensor, the sensor in
the indoor unit and the resulting ambient temperature stratification
conditions, which are always different from one room to another.
when maximum power is required straight away.
The remote control can be set to control four different units in an open space for unified control, or customised according to
temperature, timer, operating mode, and all other functions.
iFlap Function
The air flow can be released into the room
in an “intelligent” way based on whether
the unit is set to heating or cooling mode,
thanks to a special system that controls
the oscillation of the horizontal flap.
One for all One to One
Adjustable set point from 10° to 32° C
both in cooling and heat pump modesI
SE
RI
SE
RIE
SIE
S
33www.argoclima.com
34 www.argoclima.com
Technical Data
Indoor units
MODEL AWIAS87 W/B AWIAS8 W/B
Specifications Units
Air flow rate I.U. (sl.-l.-m.-h.) m³/h 250-410-480-600 250-410-480-600
Dehumidification l/h 1,5 1,5
Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings
Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 21-29-36-39 21-29-36-39
Electrical power supply V/Ph/Hz 230/1/50 230/1/50
Power input kW 0,031 0,031
Current consumption A 0,13 0,13
Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)
Gas pipe diameter mm (“) 9,52(3/8”) 9,52(3/8”)
Net weight I.U. kg 10,5 10,5
Net dimensions I.U. (H./W./D.D of recess-fitted I.U.) mm 305x895x195/110 305x895x195/110
I SE
RIE
SI
SE
RIE
S
35www.argoclima.com
Dati Tecnici
MODEL AWIA S7F AWIB S9
Specifications Units
Air flow rate I.U. (sl.-l.-m.-h.) m³/h 390-430-470-450 410-580-710-880
Dehumidification l/h 1,5 2,0
Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings
Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 23-29-36-39 29-35-43-47
Electrical power supply V/Ph/Hz 230/1/50 230/1/50
Power input kW 0,031 0,086
Current consumption A 0,13 0,40
Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)
Gas pipe diameter mm (“) 9,52(3/8”) 12,7(1/2”)
Net weight I.U. kg 8 12
Net dimensions I.U. (H./W./D.) mm 270x805x215 285x995x240
MODEL AFIA S11 AFIB S11
Specifications Units
Air flow rate I.U. (sl.-l.-m.-h.) m³/h 450-500-590-700 615-665-760-830
Dehumidification l/h 1,3 2,3
Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings
Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 22/26/30/37 28/30/37/45
Electrical power supply V/Ph/Hz 230/1/50 230/1/50
Power input kW 0,017 0,019
Current consumption A 0,07 0,08
Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)
Gas pipe diameter mm (“) 9,52(3/8”) 12,7(1/2”)
Net weight I.U. kg 18 18
Net dimensions I.U. (H./W./D.) mm 600x750x220 600x750x220
I S
ER
IS
ER
IES
IES
36 www.argoclima.com
Dati Tecnici
MODEL FCIA S8 FCIB S9
Specifications Units
Air flow rate I.U. (sl.-l.-m.-h.) m³/h 450-500-590-700 615-665-760-830
Dehumidification l/h 1,3 2,3
Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings
Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 24-26-30-37 35-40-46-49
Electrical power supply V/Ph/Hz 230/1/50 230/1/50
Power input kW 0,037 0,075
Current consumption A 0,17 0,33
Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)
Gas pipe diameter mm (“) 9,52(3/8”) 12,7(1/2”)
Net weight I.U. kg 23,5 23,5
Net dimensions I.U. (H./W./D.) mm 680x900x190 680/900/190
MODEL SDIA S8 SDIB S9
Specifications Units
Air flow rate I.U. (sl.-l.-m.-h.) m³/h 300-340-380-470 470-520-600-680
Dehumidification l/h 1,3 3,3
Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings
Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 24-26-30-37 35-40-46-49
Electrical power supply V/Ph/Hz 230/1/50 230/1/50
Power input kW 0,037 0,075
Current consumption A 0,17 0,33
Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)
Gas pipe diameter mm (“) 9,52(3/8”) 12,7(1/2”)
Net weight I.U. kg 25 25
Net dimensions I.U. (H./W./D.) mm 585x890x190 585x890x190
I SE
RIE
SI
SE
RIE
S
37www.argoclima.com
MODEL ADIC S10
Specifications Units
Air flow rate I.U. (sl.-l.-m.-h.) m³/h 500/600/700/1000
Dehumidification l/h 2,5
Fan speed N° Auto + 3 remote control settings
Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 35-40-46-49
Electrical power supply V/Ph/Hz 230/1/50
Power input kW 0,114
Current consumption A 0,51
Liquid pipe diameter mm (“) 6,35(1/4”)
Gas pipe diameter mm (“) 12,7(1/2”)
Net weight I.U. kg 23,5
Net dimensions I.U. (H./W./D.) mm 680 x 900 x 190
MODEL ASIA S8 ASIB S9
Specifications Units
Air flow rate I.U. (sl.-l.-m.-h.) m³/h 470-500-600-700 500-530-630-750
Dehumidification l/h 1,2 2,3
Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings
Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 35-37-40-44 35-37-40-44
Electrical power supply V/Ph/Hz 230/1/50 230/1/50
Power input kW 0,087 0,087
Current consumption A 0,41 0,41
Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)
Gas pipe diameter mm (“) 9,52(3/8”) 12,7(1/2”)
Net weight kg 19 20,5
Net dimensions I.U. (H./W./D.) mm 296x575x575 296x575x575
Net dimensions of grille (H./W./D.) mm 41x730x730 41x730x730
ASIC S10
680/840/1020/1140
3,6
Auto + 3 remote control settings
41/44/45/46
230/1/50
0,175
0,77
15,88(5/8”)
12,7(1/2”)
22
338x860x860
41x730x730
I S
ER
IS
ER
IES
IES
38 www.argoclima.com
Type
Applications
Outdoor Units
Indoor UnitsA
EI1G
30
AEI
1G40
AEI
1G50
B
AEI
1G65
AEI
1G80
AEI
1G11
0
Wal
l
Floo
r
Floo
r/C
eilin
g
Floo
r/R
eces
s-Fi
tted
Cei
ling
Cas
sett
e
Duc
ted
Hyd
roK
it
Uni
t for
DH
W
air/air mono-split x x x x x x x x x x x x
air/water mono-split
domestic hot water x x x
one floor area x x x x x
two floor areas x x x x x
one fan coil area x x x x xone floor area and one fan coil area x x x x xone floor area and one radiator area x x x x x
one radiator area x x x x xone radiator area and domestic hot water
x x x x x
air/air multi-split x x x x x x x x x x
mixed multi-split
air/air and domestic hot water
x x x x x x x x x x x
air/air and air/water x x x x x x x x x x xair/air, air/water and domestic hot water
x x x x x x x x x x x
I SE
RIE
SI
SE
RIE
S
iSERIESTM applications
39www.argoclima.com
AEI1G50B + HKBE
watertemperatureat inlet/outlet
outdoor air temperature
Heating Minimum Nominal Maximum
30/35 °C +7 °CKw 0,95 5,27 6,23
COP * 4,14
30/35 °C -7 °CKw * 4,02 4,73
COP * 2,38 *
45/50 °C +7 °CKw * 4,78 5,27
COP * 2,96 *
45/50 °C -7 °CKw * 3,10 3,65
COP * 1,92 *
40/45 °C +7 °CKw * 4,93 5,80
COP * 3,31 *
40/45 °C -7 °CKw * 3,70 4,35
COP * 2,3 *
20/25 °C +7 °CKw * 6,20 7,30
COP * 5,36 *
20/25 °C -7 °CKw * 3,16 3,72
COP * 2,73 *
Cooling Minimum Nominal Maximum
18/23 °C +35 °CKw 0,84 4,50 5,73
EER * 3,57 *
7/12 °C +35 °CKw * 3,15 3,47
EER * 1,97 *
I S
ER
IS
ER
IES
IES
* The data provided in the table was measured in accordance with European standard EN14511, which requires nominal efficiency and output tests.
In order to size systems correctly, the minimum output at standard conditions of +7°C and the maximum output values for all applications are also provided.
Preliminary data at catalogue date
40 www.argoclima.com
iSERIESTM applications
AEI1G65B + HKBE
watertemperatureat inlet/outlet
outdoor air temperature
Heating Minimum Nominal Maximum
30/35 °C +7 °CKw 1,82 8,20 9,33
COP * 4,2 *
30/35 °C -7 °CKw * 4,99 5,41
COP * 2,64 *
50/55 °C +7 °CKw * 5,65 6,50
COP * 2,63 *
50/55 °C -7 °CKw * 3,50 3,89
COP * 1,58 *
40/45 °C +7 °CKw * 7,10 7,60
COP * 3,2 *
40/45 °C -7 °CKw * 4,20 4,55
COP * 2,06 *
20/25 °C +7 °CKw * 8,70 9,45
COP * 5,48 *
20/25 °C -7 °CKw * 4,50 5,26
COP * 2,7 *
Cooling Minimum Nominal Maximum
18/23 °C +35 °CKw 1,57 6,00 7,00
EER * 3,6 *
7/12 °C +35 °CKw * 5,20 5,64
EER * 2,58 *
I SE
RIE
SI
SE
RIE
S
* The data provided in the table was measured in accordance with European standard EN14511, which requires nominal efficiency and output tests.
In order to size systems correctly, the minimum output at standard conditions of +7°C and the maximum output values for all applications are also provided.
Preliminary data at catalogue date
41www.argoclima.com
iSERIESTM applications
AEI1G80B + HKCE
watertemperatureat inlet/outlet
outdoor air temperature
Heating Minimum Nominal Maximum
30/35 °C +7 °CKw 1,70 9,42 11,30
COP * 4,03 *
30/35 °C -7 °CKw * 5,65 6,65
COP * 2,5 *
50/55 °C +7 °CKw * 6,40 7,53
COP * 2,49 *
50/55 °C -7 °CKw * 3,90 4,60
COP * 1,49 *
40/45 °C +7 °CKw * 8,10 9,55
COP * 3,06 *
40/45 °C -7 °CKw * 5,18 6,10
COP * 1,95 *
20/25 °C +7 °CKw * 10,24 12,05
COP * 5,03 *
20/25 °C -7 °CKw * 5,12 6,02
COP * 2,56 *
Cooling Minimum Nominal Maximum
18/23 °C +35 °CKw 1,60 7,98 9,40
EER * 4,01 *
7/12 °C +35 °CKw * 6,87 8,10
EER * 2,84 *
I S
ER
IS
ER
IES
IES
* The data provided in the table was measured in accordance with European standard EN14511, which requires nominal efficiency and output tests.
In order to size systems correctly, the minimum output at standard conditions of +7°C and the maximum output values for all applications are also provided.
Preliminary data at catalogue date
Made from ABS with a high-gloss pearl finish, Xfetto has a modern yet linear design that
fits well in any space.
Attractive, slim, versatile and…
with no outdoor unit
XF
ET
TO
XF
ET
TO
43www.argoclima.com
XF
ET
TO
XF
ET
TO
44 www.argoclima.com
AIR / AIR
Only 2 holes in the wall are needed…to connect the air-condensed Xfetto model with the outside, as long as the holes are in a perimeter wall. Xfetto air/air houses an outdoor unit within its single case and in order to operate correctly requires a constant exchange of air with the outside because it uses air to cool the condenser. This air exchange takes place via two 16 cm holes (1 intake hole and 1 outflow hole), to be made in the installation wall, which therefore must be a perimeter wall. Thanks to the special grilles the unit can be installed very easily even from indoor the room, through walls or structures up to 2 metres thick or directly onto large windows with no loss of performance... Xfetto is also designed to allow recessed wall installation and in this instance its visible depth is reduced to only 10 centimetres.
When Xfetto operates in cooling mode or dehumidification only, the condensation is released by internal evaporation in the condenser: therefore there is no need to provide a condensation discharge pipe for the cooling-only models. Condensation discharge is however required for models with a heat pump, even though its use is limited to heat pump operation. The condensation can be drawn either indoor or outside the room using the dedicated duct indoor the device’s chassis.
16 cm
Air condensed
only 26 cm
thick
45www.argoclima.com
Can also be installed on non-perimeter walls Xfetto water-condensed still eliminates the problem of the outdoor unit by housing it within its single case, but it uses water instead of air to cool the condenser. This solution has the advantage of not requiring holes in the wall and thus allows the device to be installed on any type of wall, perimeter or not.The advantages of this application include: great energy efficiency (COP up to 4.68), low power consumption (630 watts to achieve a heat output of over 3 kW) and extremely quiet operation thanks to the fact that the condenser, being water-cooled, has no ventilation system. The water-condensed version of Xfetto consumes just one cubic metre of water per day (less than one euro’s worth). Unique and special, it provides solutions for niche applications that arise much more often than you may think... From residences in historic buildings with large supplies of water, to systems with cooling towers, heat pumps and/or boilers on closed-circuit loops even when controlled by BMS, such as Lyon Airport.
Mains water useThe ideal application for areas with strict regulations governing modifications to building facades and without limitations on water use. The system nevertheless has a low level of water consumption that may reach up to one cubic metre of water per day under normal summer operating conditions, with a daily cost of less than one euro. It only requires connection to two water pipes, inflow and outflow.
Closed circuit water useXfetto can also operate as a terminal in a closed circuit water loop system with water at 30°C in accordance with EN14511 specifications. The water used to cool the condenser is fed into a circuit and drawn to a cooling tower where it is cooled and then reused by the device.
WATER / AIR COP up to 4.68
Water condensed
Mains water Recirculated waterKey
Tap
Flow rate valve
0.5 mm mechnical mesh filter
Water inlet hose
Flow switch
Solenoid
Water outlet hose
Water heat exchanger
Water inlet
Water outlet
XF
ET
TO
XF
ET
TO
A real advantage for on/off versions, both air or water-condensed, is the ability to connect Xfetto to a central heating system and use it as a radiator connected to the heating system circuit using the dedicated hydraulic module (optional), which also includes a three-way bypass valve.
To use the radiator function Xfetto must be connected to the central heating system, whether it is centralised or autonomous. Suitable checks should first be carried out on the system to determine the water flow rate conditions in terms of volume and heat output.
The connection can be made using the dedicated optional kit, which in concept represents a kind of interface module between xfetto and the central heating system. Without this kit, xfetto can still be installed with the maximum flexibility as an air conditioner/heat pump without an outdoor unit (for example in places where no central heating system is installed due to climatic conditions).
The connection kit to the central heating system is symmetrical and can be fitted on the left or right of the device. It is designed to adapt to various different existing situations (pipes on the right, pipes on the left, delivery on the right and return on the left, delivery above and return below...). This means that the same kit can be used for both sides. The size and shape of the kit elegantly covers most types of hydraulic connection.
The kit is comprised of a plastic casing and all the components (electronic and hydraulic) required for radiator operation. The installer need only make the hydraulic connections to the central heating system delivery and return pipes.
With the hydraulic module, as a radiator substitute
Installation with the hydraulic module for connection to a boiler
Radiator function!
goodbye outdoor unit...
46 www.argoclima.com
XF
ET
TO
XF
ET
TO
47www.argoclima.com
DCI SPL/HPL
SVPWM 180° full DC inverter technology
Heat pump with cool,
heat, dehumidify and fan functions
Universal multifunction remote control with LCD display,
Feel sensor, wall mount and transmitter with a wide range of
operation
Temperature check comparison between remote control
sensor and unit sensor
iFeel function
ECO and High Power functions
Horizontal deflector with 6 positions set via remote control and
iFlap function for intelligent air distribution
Automatic fan speed and/or three set speeds available via
remote control
Condensing with variable speed fan
Intelligent Cold draft and Defrost functions
Additional electrical heating (820 watts) activated by the
software in auto mode when the unit is unable to balance the
thermal load, or manually activated/deactivated via remote
control as a booster for the heat pump or as a Fan Heater
Auto-restart following black outs and excess pressure
protection devices
High efficiency rotary compressor covered by a 5-year
warranty
Optional feet for floor installation
(windows, loft conversions...)
Argo Xfetto is protected by Patent No. 261412 granted to Argoclima S.p.A. on 8th January 2009
n°dB(A)
PRODUCT NAME XFETTO DCI
stinU1,85 (1,10-2,93) 2,27 (0,90-3,05)
0,85kWA A
2,61 3,17330-300-280
1,0
43-38-35
Cooling HeatingkW
0,710 0,715355 -
230/1/50
162by duct, outside or inside the room
R410A
49735x839x260-280
3 + Auto
ABCDEFG(kW/kW)m3/hlitres/h
V/Ph/HzkW
kWh
mm
Kgmm
FeaturesCooling capacityAdditional electrical resistanceEnergy label classE.E.R. / C.O.P.Air flowrate (h.-m.-l.)DehumidificationFan speedsSound pressure (h.-m.-l.) Power supplyRunnig consumptionAnnual energy cons. - A/C (500h)-Dir. 2002/31/CERefrigerant typeDucts diameterCondensate dischargeNet weightNet dimension (H./W./D.)
XF
ET
TO
XF
ET
TO
Installation on a perimeter wall
Automatic switching from cooling to heating action based on
the set temperature (235H)
Radiator operation when connected to the heating system
circuit using the dedicated hydraulic module (optional), which
includes a three-way bypass valve
Remote control with digital 24h thermostat/timer and up to 4
addresses
Dual temperature sensor (on the unit and on the remote control)
iFeel & Night functions
Horizontal deflector that can be switched between fixed and
oscillating positions via remote control
Condensing with variable speed outdoor fan for maximum
quietness
Tangential fan with three programmable speeds or automatic
speed control
Device that prevents the release of cold air into the room by
activating heat pump mode during defrosting cycles (235H)
Device that prevents the circulation of air in the room when
the heating water temperature is below 40°C in radiator mode
Precision thermostat with settings from 6°C to 40°C in radiator
mode
Auto restart following power black outs
Electronic protection against excess pressure
High efficiency rotary compressor covered by a 5-year warranty
Optional feet for floor installation
(windows, loft conversions...)
245C cooling only
235H heat pump
Air condensed
48 www.argoclima.com
Installation on a perimeter wall
Argo Xfetto is protected by Patent No. 261412 granted to Argoclima S.p.A. on 8th January 2009
The technical data provided refers to European Standard EN14511 - Directive 2002/31/CE
PRODUCT NAME XFETTO 245C XFETTO 235H
2,45 2,35 2,25BTU/h 8.360 8.020 7.700
2.110 2.020 1.9352,10 2,10
ABCDEFG A A CE.E.R. / C.O.P. 2,62 2,61 2,65
m³/h 330-300-280 330-300-280l/h 1,2 1,0n° 3 + Auto 3 + Auto
45-43-41 45-43-4142-39-32 42-39-32230/1/50 230/1/50
0,935 0,900 0,850468 450 -
0,027 0,027R410A R410A
mm 162 1621/2" 1/2" gas F
mm - 18Kg 50 52mm 735/839/260-280 735x839x260-280
Features Units Cooling Cooling Heating
Cooling/Heating capacity (A/Conditioner mode)kW
kcal/hHeating capacity (Water Radiator mode) kWEnergy label class
(kW/kW)Air flowrate (h.-m.-l.)DehumidificationFan speedsSound pressure in Air/Conditioner mode (h.-m.-l.) dB(A)Sound pressure in Water radiator mode (h.-m.-l.) dB(A)Power supply V/Ph/HzRunning consumption in Air/Conditioner mode kWAnnual energy cons.- A/C(500h)-Directive 2002/31/EC kWhRunning consumption in Water radiator mode kWRefrigerant typeDucts diameterHydraulic connection diameter on the heating plant (W.R.mode) inchCondensate discharge not requested by duct, outside or inside the room
Condensate drain connection diameter (outside)Net weight Net dimensions (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
XF
ET
TO
XF
ET
TO
49www.argoclima.com
Can be installed on any wall, even non-perimeter walls,
because it does not require holes in the wall
Designed to work with mains water or a well/groundwater source, it
can also operate as a terminal in a closed circuit water loop system
with water at 30°C in accordance with EN14511 specifications
Very high levels of efficiency (EER up to 4.68)
Automatically switches from cooling to heating based on the
set temperature (235HP)
Operates as a radiator when connected to the heating system
circuit using the dedicated hydraulic module (optional), which
includes a three-way bypass valve
High efficiency plate heat exchanger with a solenoid to cut off
mains water circulation when the compressor is off
Antifreeze protection on condensation water circuit
Installation of a viewable filter on the mains water inlet (to be
completed by installer) recommended
Remote control with digital 24h thermostat/timer and up to 4
addresses
Dual temperature sensor (on the unit and on the remote control)
Dry, Fan Only, iFeel and Night Functions
Horizontal deflector that can be switched between fixed and
oscillating positions via remote control
Washable air filters
Tangential fan with three programmable speeds or automatic
speed control
Device that prevents the release of cold air into the room, in
heat pump mode (235HP)
Device that prevents the circulation of air in the room when
the heating water temperature is below 40°C in radiator mode
Precision thermostat with settings from 6°C to 40°C in
radiator mode
Auto restart following power black outs
Electronic protection against excess pressure
High efficiency rotary compressor covered by a 5-year
warranty
Optional feet for floor installation (windows, loft conversions...)
245SC H2O cooling only
235HP H2O heat pump
Can be installed on any wall, even non-perimeteer wallsnon-perimete
Water condensed
Argo Xfetto is protected by Patent No. 261412 granted to Argoclima S.p.A. on 8th January 2009
Mains water - Cool: Amb. temp. 27°C d.b. / 19°C w.b. - Water temp. in 18°C - out 36°C / Heat pump: Amb. temp. 20 °C d.b. - Water temp. in 18°C - out 6°C Water loop - Cool: Amb. temp. 27°C d.b. / 19°C w.b. - Water temp. in 30°C - out 35°C / Heat pump: Amb. temp. 20°C d.b. - Water temp. 15°CRadiator - Amb. temp. 20°C - Water temp. in 70°C - out 60°C
PRODUCT NAME
Water loop(*) Water loop(*)
Raffreddamento2,83 2,7 2,95 3,15 3,00 3,56
BTU/h 9.650 9.200 10.060 10.740 10.230 12.1402.430 2.320 2.540 2.710 2.580 3.060
ABCDEFG - B - - A CE.E.R. / C.O.P. 4,42 4,15 4,68 3,80 4,41 4,14
m³/h 330-300-280 330-300-280 330-300-280litri/h 1,2 1,2 1,3 1,3
n° 3 + Auto 3 + Auto 3 + Auto 3 + Auto44-42-41 44-42-41 44-42-41 44-42-41
230/1/50 230/1/500,640 0,650 0,630 0,830 0,680 0,860
- 325 - - 340 -m³/h 0,150 0,525 0,150 0,525
2,9 38,0 2,9 40,3R410A R410A R410A R410A
1/2" (gas) F 1/2" (gas) F 1/2" (gas) F 1/2" (gas) Fmm 13/18 13/18 13/18 13/18
3,47 3,35 3,58 - 3,68 -- - - 2,04 - 2,7
2,1 2,10,027 0,027
m³/h 0,19 0,192,9 2,91/2" F 1/2" (gas) F42-39-32 42-39-32
Kg 46 48mm 735/839/260-280 735x839x260-280
XFETTO 245SCH2O XFETTO 235HPH2OOperation Town water Town water
wa
ter l
oo
p:
sta
nd
ard
co
nd
itio
ns
EN
14
51
1
Features Units Raffr. Risc. Raffr. Risc.
Cooling/Heating capacity (Air-Conditioner mode)kW
kcal/hEnergy label class
(kW/kW)Air flowrate (h.-m.-l.)DehumidificationFan speedsSound pressure in Air-Conditioner mode (h.-m.-l.) dB(A)Power supply V/Ph/HzRunning consumption in Air-Conditioner mode kWAnnual energy cons.- A/C(500h)-Directive 2002/31/EC kWhWater flowrate for the heat exchanger Pressure drops KPaRefrigerant typeWater connection diameter (in/out) inchCondensate drain connection diameter (inside or outside)Heat transferred to water kWHeat moved from water kWHeating capacity in Water Radiator mode kWRunning consumption in Water radiator mode kWWater flowrate in Water Radiator modePressure drops in Water Radiator mode kPaHydraulic connection diameter to the heating plant (W.R.mode) inchSound pressure in Water radiator mode (h.-m.-l.) dB(A)Net weight Net dimensions (H./W./D.)
XF
ET
TO
XF
ET
TO
52 www.argoclima.com
X1
X1
Wall-mounted
split unit air conditioner and heat pump
Wall-mounted split unit with heat pump
Elegant design in PMMA (high quality material)
Environmentally-friendly refrigerant R410A
Automatic switching between cooling and heating
Equipped with a multi-function remote control with digital timer,
which allows operating cycles to be programmed over 24 hours
Tangential fan with three programmable speeds or automatic
speed control
Remote-controlled horizontal deflector: with 5 set positions or
automatic oscillation
Manually adjustable vertical deflector
Washable air filters
Activated carbon filters
BIO photocatalytic filter
Easily removable front panel secured by magnets
Automatic adaptation to night-time temperature variations
function with 4 different programmes
Dehumidify only function
Turbo function for instant coolness/warmth
Automatic restart following power black outs
Electronic compressor protection
High efficiency rotary compressor
Easy magnetic placement
X1 G 25 X1 G 35PRODUCT NAME
Indoor Unit X1 G 25HL X1 G 35HL
Outdoor Unit X1 G 25SH X1 G 35SH
Specifications Units Cooling Heating Cooling Heating
CapacitykW 2,7 2,85 3,5 3,8
BTU/h 9200 9720 12000 12960
Energy Class ABCDEFG A A A A
E.E.R. / C.O.P. (kW/kW) 3,21 3,61 3,21 3,61
Indoor unit air flow rate (h.m.l.) m³/h 450-400-320 500-450-380
Dehumidification l/h 0,8 1,2
Fan speed (Indoor / Outdoor) N° 3/1 3/1
Sound pressure Indoor (h.m.l.) dB(A) 40-37-34 40-37-34
Sound pressure Outdoor (h.) dB(A) 49 49
Power supply V/Ph/Hz 230/1/50 230/1/50
Power input kW 0,84 0,79 1,09 1,05
Annual energy consumption (500h) kWh 420 - 545 -
Compressor type Rotary Rotary
Refrigerant type R410A R410A
Liquid pipe diameter mm (inch") 6,35(1/4”) 6,35(1/4”)
Gas pipe diameter mm (inch") 9,52(3/8”) 12,7 (1/2”)
Length of pipes (with standard charge) m 7 7
Length of pipes (with additional charge) m 10 10
Maximum height difference (outdoor unit above) m 5 5
Maximum height difference (indoor unit above) m 5 5
Net dimensions Indoor (H./W./D.) mm 290x800x186 290x800x186
Net dimensions Outdoor (H./W./D.) mm 480x600x250 540x700x255
Net weight Indoor/Outdoor Kg 10/26 10/30
The technical data provided refers to European Standard EN14511 - Directive 2002/31/CE
X1 G 25 X1 G 35
53www.argoclima.com
Wall-mounted split unit with heat pump
DC Inverter technology for maximum comfort
Elegant design in PMMA (high quality material)
Environmentally-friendly refrigerant R410A
Automatic switching between cooling and heating
Equipped with a multi-function remote control with digital timer,
which allows operating cycles to be programmed over 24 hours
Tangential fan with three programmable speeds or automatic
speed control
Remote-controlled horizontal deflector: with 5 set positions or
automatic oscillation
Manually adjustable vertical deflector
Washable air filters
Activated carbon filters
BIO photocatalytic filter
Easily removable front panel secured by magnets
Automatic adaptation to night-time temperature variations function
with 4 different programmes
Dehumidify only function
Turbo function for instant coolness/warmth
Automatic restart following power black outs
Electronic compressor protection
High efficiency rotary compressor
Wall-mounted split unit
air conditioner and heat pump – DC Inverter
Easy magnetic placement
X1l G 25 X1l G 35PRODUCT NAME
Indoor Unit X1I G 25HL X1I G 35HL
Outdoor Unit X1I G 25SH X1I G 35SH
Specifications Units Cooling Heating Cooling Heating
Capacity nominal (min-max)kW 2,60 (1,45-4,0) 2,90 (1,4-5,0) 3,60 (1,84-4,10) 3,80 (1,50-5,10)
BTU/h 8.870 (4.950-13.650) 9.900 (4,8-17.100) 12.280 (6.280-14.000) 13.000 (5.120-17.400)
Energy Class ABCDEFG A A A A
E.E.R. / C.O.P. - nominal (min-max) (kW/kW) 3,42 (4,53-2,94) 3,67 (4,7-3,1) 3,43 (2,87-4,18) 3,62 (3,0-4,4)
Indoor unit air flow rate (h.m.l.) m³/h 450-400-320 500-450-380
Dehumidification l/h 0,8 1,2
Fan speed (Indoor / Outdoor) N° 3/1 3/1
Sound pressure Indoor (h.m.l.) dB(A) 38-35-32 40-37-34
Sound pressure Outdoor (h.) dB(A) 51 52
Power supply V/Ph/Hz 230/1/50 230/1/50
Power input - nominal (min-max) kW 0,76 (0,32-1,36) 0,8 (0,3-1,6) 1,050 (0,44-1,43) 1,05 (0,35-1,70)
Annual energy consumption (500h) kWh 380 - 525 -
Compressor type Rotary Rotary
Refrigerant type R410A R410A
Liquid pipe diameter mm (inch") 6,35(1/4") 6,35(1/4")
Gas pipe diameter mm (inch") 9,52(3/8") 12,7 (1/2")
Length of pipes (with standard charge) m 7 7
Length of pipes (with additional charge) m 10 10
Maximum height difference (outdoor unit above) m 5 5
Maximum height difference (indoor unit above) m 5 5
Net dimensions Indoor (H./W./D.) mm 290x800x186 290x800x186
Net dimensions Outdoor (H./W./D.) mm 540x700x255 540x700x255
Net weight Indoor/Outdoor Kg 10/26 11/30
The technical data provided refers to European Standard EN14511 - Directive 2002/31/CE
X1
X11
X1l G 25 X1l G 35
55www.argoclima.com
Split and package on/off, heat
pump and low ambient, up to
14 kW of thermal capacity for
mono and multi applications,
hi-wall, floor/ceiling or built-in
(cassette) types.
ON
OF
ON
OF
FF
56 www.argoclima.com
ON
OF
FO
NO
FF
Ulisse 13 PCL - 10 CLA
Floor console, cooling only
Only 24 cm depth, suitable for fixed or moveable
floor installations
Small condensing case, specifically projected to be placed
on balcony or window
Automatic condensate vaporization through the case
Infrared remote control with 24h digital timer and 4-addressing
possibility, night set back, start-up of air-conditioning or
dehumidifying or ventilation only modes, temperature digital
adjustment and room temperature control by a special sensor
indoor the remote control
Double temperature sensor (on remote control / on indoor unit)
“I Feel” feature
Dry function
Three-speed fan by remote control
Frontal air-intake, making possible its placement even between
two walls
AeroQuip quick connectors to easily disconnect and re-connect
the outdoor unit for a fixed installation
Adjustable air louver, granting the best fresh air diffusion
Washable air filters
Auto restart after a power supply black out
Electronic protection against over-pressures
High efficiency rotary compressor
Accessories for the outside fixed installation of the case supplied
with the unit
Optional pipe-extension kits connecting Indoor and Outdoor
units (2 and 4m)
OZONEFRIENDLY
R410Aeco
Cooling only
PRODUCT NAME ULISSE 10CLA ULISSE 13PCLA
2,98 4,00
BTU/h 10.160 13.640
2.560 3.440
ABCDEFG A A
E.E.R. /C.O.P. 3,22 3,21
370 400-375-335
l/h 1,2 1,9
n° 3 + Auto / 1 3 + Auto / 1
36-36-34 37-36-34
45 42
230/1/50 230/1/50
0,925 1,25
463 625
R410A R410A
m 2 2
m 2-4 2-4
m 1,2 1,2
m 5,2 5,2
Kg 44/9,5 44/15
mm 790x580x245 790x580x245
mm 435x440x230 490x525x250
Features Units Cooling Cooling
Capacity
kW
kcal/h
Energy label class
(kW/kW)
Air flowrate (h./h.-m.-l.) m
Dehumidification
Fan speeds (Indoor / Outdoor)
Sound pressure Indoor (h.m.l.) dB(A)
Sound pressure Outdoor (h.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE kWh
Refrigerant type
Standard pipe lenght
Additional pipe lenght
Max. height between units (Outdoor on the top)
Max. height between units (Indoor on the top)
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
57www.argoclima.com
Ulisse 10 HLA
Floor console, cooling and heat pump
Only 24 cm depth, suitable for fixed or moveable
floor installations
Small condensing case, specifically projected to be placed
on balcony or window
Infrared remote control with 24h digital timer and 4-addressing
possibility, night set back, start-up of air-conditioning
or dehumidifying or ventilation only modes, temperature digital
adjustment and room temperature control by a special
sensor indoor the remote control
Double temperature sensor (on remote control / on indoor unit)
“I Feel” feature
Dry function
Three-speed fan by remote control
Frontal air-intake, making possible its placement even
between two walls
AeroQuip quick connectors to easily disconnect and
re-connect the outdoor unit for a fixed installation
Adjustable air louver, granting the best fresh air diffusion
Washable air filters
Auto restart after a power supply black out
Electronic protection against over-pressures
High efficiency rotary compressor
Accessories for the outside fixed installation of the case
supplied with the unit
Optional pipe-extension kits connecting Indoor and Outdoor
units (2 and 4m)
OZONEFRIENDLY
R410Aeco
Heat pump
PRODUCT NAME ULISSE 10HLA
2,98 3,34
BTU/h 10.160 11.390
2.560 2.870
ABCDEFG A A
E.E.R. /C.O.P. 3,22 3,67
370
l/h 1,2
n° 3 + Auto / 1
35-31-29
39
230/1/50
0,925 0,910
463
R410A
m 2
m 2-4
m 1,2
m 5,2
Kg 44/15
mm 790x580x245
mm 490x525x250
Features Units Cooling Heating
Capacity
kW
kcal/h
Energy label class
(kW/kW)
Air flowrate (h./h.-m.-l.) m
Dehumidification
Fan speeds (Indoor / Outdoor)
Sound pressure Indoor (h.m.l.) dB(A)
Sound pressure Outdoor (h.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE kWh
Refrigerant type
Standard pipe lenght
Additional pipe lenght
Max. height between units (Outdoor on the top)
Max. height between units (Indoor on the top)
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
ON
OF
ON
OF
FF
AW 726/735 H
Automatic change-over between cooling and heating modes
Infrared remote control; 24h digital timer;
4-addressing possibility
Double temperature sensor (on the unit and indoor
the remote control)
“I Feel” feature, granting the best comfort conditions
Dry function
Three-speed tangential fan by remote control
Night set-back capability
Usable also without remote control
Horizontal flap by remote control: swinging
or six fixed positions
Vertical flap with rear protection grille, allowing a safe
installation of the indoor unit also at low distance
from the floor (min. 1,7 mt)
Washable filters; active carbon filters (optional)
Double condensate discharge (right/left)
to make easier the installation
Auto restart after a power supply black out
Electronic protection of the indoor units: anti-freeze;
heating function disabled during defrosting cycle,
electronic protection against over-pressures
High efficiency rotary compressor
Self-diagnostic functions
58 www.argoclima.com
R410Aeco
ifeel 3speed
Heat pump
PRODUCT NAME AW726H AW735H
AW726HL/F AW735HL/FAE726SH AE735SH
2,65 3,00 3,4 3,7BTU/h 9.040 10.230 11.600 12.620
2.280 2.580 2.920 3.180ABCDEFG A A A A
E.E.R. / C.O.P. 3,44 3,80 3,21 3,61450-400-370 470-430-390
l/h 1,2 - 1,5 -n° 3 + Auto/1 3 + Auto/1
41-36-32 41-36-3237 40
230/1/50 230/1/500,770 0,790 1,060 1,025
A 3,50 3,60 5,40 5,20385 - 530 -
R410A R410A6,35(1/4") 6,35(1/4")9,52(3/8") 12,7(1/2")
m 7,5 7,5m 15 15
20 20m 7 7m 7 7Kg 8/35 8/35mm 270x805x214 270x805x214mm 540x700x265 540x700x265
Indoor unitOutdoor unitFeatures Units Cooling Heating Cooling Heating
Cooling/Heating capacity kW
kcal/hEnergy label class
(kW/kW)Air flowrate Indoor (h.m.l.) m3/hDehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.m.l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzPower input kWRunning consumptionAnnual energy cons.-cooling(500h)-Dir. 2002/31/CE kWhCompressor type Rotary RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeGas additional charge gr/mMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
ON
OF
FO
NO
FF
59www.argoclima.com
AW 752/764H/764H3
Automatic change-over between cooling and heating modes
Available in single-phase and three-phase versions (764H3)
Infrared remote control; 24h digital timer;
4-addressing possibility
Double temperature sensor (on the unit and indoor the
remote control)
“I Feel” feature, granting the best comfort conditions
Dry function
Three-speed tangential fan by remote control
Night set back capability
Usable also without remote control
Horizontal flap by remote control: swinging or six fixed positions
Vertical flap with rear protection grille, allowing a safe installation
of the indoor unit also at low distance from the floor
(min. 1,7 mt)
Washable air filters; active carbon filters (optional)
Double condensate discharge (right/left) to make easier
the installation
Auto restart after a power supply black out
Electronic protection of the indoor units: anti-freeze;
heating function disabled during defrosting cycle,
electronic protection against over-pressures
Anti-freeze protection of the outdoor unit
High efficiency rotary compressor
Self-diagnostic functions
Single-phase and three-phase (764H3) power supply
R410Aeco
ifeel 3speed
Heat pump
PRODUCT NAME AW752H AW764H AW764H3
AW752HL AW764HL AW764HLAE752SH AE764SH AE764SH3
5,00 5,80 6,60 7,80 6,80 8,00BTU/h 17.100 19.780 22.500 26.600 23.200 27.280
4.300 4.990 5.676 6.710 5.848 6.880ABCDEFG A A A A A A
E.E.R. / C.O.P. 3,23 3,82 3,22 3,63 3,24 3,64880-710-580 880-710-580 880-710-580
l/h 1,5 - 2,0 - 2,0 -n° 3 + Auto/1 3 + Auto/1 3 + Auto/1
46-43-38 49-43-38 49-43-3843 47 47
230/1/50 230/1/50 400/3N/501,55 1,52 2,05 2,15 2,10 2,20
A 7,00 6,70 9,20 9,50 4,10 4,30775 - 1025 - 1050 -
R410A R410A R410A6,35(1/4") 6,35(1/4") 6,35(1/4")12,7(1/2") 15,88(5/8") 15,88(5/8")
m 10 12,5 12,5m 20 30 30
20 25 25m 15 15 15m 15 15 15Kg 12/57 12/71 12/71mm 285x995x240 285x995x240 285x995x240mm 630x830x305 735x940x340 735x940x340
Indoor unitOutdoor unitFeatures Units Cooling Heating Cooling Heating Cooling Heating
Cooling/Heating capacity kW
kcal/hEnergy label class
(kW/kW)Air flowrate Indoor (h.m.l.) m3/hDehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.m.l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzPower input kWRunning consumptionAnnual energy cons.-cooling(500h)-Dir. 2002/31/CE kWhCompressor type Rotary Rotary RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeGas additional charge gr/mMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
ON
OF
ON
OF
FF
AW 726/735 CL
Able to operate with an outdoor air temperature up to -15°C
Infrared remote control; 24h digital timer; 4-addressing possibility
Double temperature sensor (on the unit and indoor the remote
control)
“I Feel” feature, granting the best comfort conditions
Dry function
Three-speed tangential fan by remote control
Night set-back capability
Usable also without remote control
Horizontal flap by remote control: swinging or six fixed positions
Vertical flap with rear protection grille, allowing safe installations
of the indoor unit even at any height from the floor
(min. 1,7 m.) (EN60335 safety standard)
Washable filters; active carbon filters (optional)
Double condensate discharge (right/left)
to make easier the installation
Auto restart after a power supply black out
Electronic protection against over-pressures
High efficiency rotary compressor
Self-diagnostic functions
60 www.argoclima.com
R410Aeco
ifeel
3speed
+43°C
-15°C
active carbonfilter
OZONEFRIENDLY
washablefilters
Cooling only
MATCHING AW726CL AW735CL
AW726CL/F AW735CL/FAE726SCL AE735SCL
2,70 3,40ABCDEFG A A
E.E.R. 3,51 3,24450-400-370 470-430-390
l/h 0,8 1,5n° 3 + Auto/1 3 + Auto/1
41-36-32 41-36-3237 40
230/1/50 230/1/500,770 1,050
A 3,40 4,70385 525
R410A R410A6,35(1/4") 6,35(1/4")9,52(3/8") 12,7(1/2")
m 7,5 7,5m 15 15
20 20m 7 7m 7 7Kg 8/34 8/34mm 270x805x214 270x805x214mm 540x700x265 540x700x265
Indoor unitOutdoor unitFeatures Units Cooling CoolingCooling capacity kWEnergy label class
(kW/kW)Air flowrate Indoor (h.-m.-l.) m3/hDehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.-m.-l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzPower input kWRunning consumptionAnnual energy cons.- cooling (500h) - Dir.2002/31/CE kWhCompressor type Rotary RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeGas additional charge gr/mMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
ON
OF
FO
NO
FF
61www.argoclima.com
AW 752 CL/CL3 -AW 764 CL3
Able to operate with an outdoor air temperature up to -15°C
Infrared remote control; 24h digital timer;
4-addressing possibility
Double temperature sensor (on the unit and indoor
the remote control)
“I Feel” feature, granting the best comfort conditions
Dry function
Three-speed tangential fan by remote control
Night set-back capability
Usable also without remote control
Horizontal flap by remote control: swinging or six fixed positions
Vertical flap with rear protection grille, allowing safe installations
of the indoor unit even at any height from the floor
(min. 1,7 m.) (EN60335 safety standard)
Washable filters; active carbon filters (optional)
Double condensate discharge (right/left) to make
easier the installation
Auto restart after a power supply black out
Electronic protection against over-pressures
High efficiency rotary compressor
Self-diagnostic functions
Single-phase and three-phase versions
R410Aeco
ifeel
3speed
+43°C
-15°C
active carbonfilter
OZONEFRIENDLY
washablefilters
Cooling only
ON
OF
ON
OF
FF
FC 735/752 CL
Able to operate with an outdoor air temperature up to -15°C
Single-phase (230V-1-50Hz) power supply
Infrared remote control; 24h digital timer;
4-addressing possibility
Double temperature sensor (on the unit and indoor
the remote control)
“I Feel” feature, granting the best comfort conditions
Dry function
Three-speed centrifugal fan by remote control
Night set-back capability
Usable also without remote control
Horizontal flap swinging or to be set to on of the six
possible fixed position by remote control
Vertical flap by manual control
Washable filters; active carbon filters (optional)
Auto restart after a power supply black out
Electronic protection against over-pressures
High efficiency rotary compressor
Self-diagnostic functions
62 www.argoclima.com
R410Aeco
ifeel
3speed
+43°C
-15°C
active carbonfilter
OZONEFRIENDLY
washablefilters
Cooling only
PRODUCT NAME FC735CL FC752CL
FC735CL FC752CLAE735SCL AE752SCL
3,40 5,00ABCDEFG A A
E.E.R. 3,24 3,23670-550-450 715-610-510
l/h 1,5 1,8n° 3 + Auto/1 3 + Auto/1
47-44-39 49-47-4040 43
230/1/50 230/1/501,05 1,55
A 4,70 7,00525 775
R410A R410A6,35(1/4") 6,35(1/4")12,7(1/2") 12,7(1/2")
m 7,5 10m 15 20
20 20m 7 15m 7 15Kg 23,5/34 23,5/55mm 680x900x190 680x900x190mm 540x700x265 630x830x305
Indoor unitOutdoor unitFeatures Units Cooling CoolingCooling capacity kWEnergy label class
(kW/kW)Air flowrate Indoor (h.-m.-l.) m3/hDehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.-m.-l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzPower input kWRunning consumptionAnnual energy cons.-cooling(500h)-Dir. 2002/31/CE kWhCompressor type Rotary RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeGas additional charge gr/mMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
ON
OF
FO
NO
FF
63www.argoclima.com
FC 752/764 CL3
Able to operate with an outdoor air temperature up to -15°C
Three-phase (400-3N-50Hz) power supply
Infrared remote control; 24h digital timer;
4-addressing possibility
Double temperature sensor (on the unit and indoor
the remote control)
“I Feel” feature, granting the best comfort conditions
Dry function
Three-speed centrifugal fan by remote control
Night set-back capability
Usable also without remote cotrol
Horizontal flap swinging or to be set to on of the six possible
fixed position by remote control
Vertical flap by manual control
Washable filters; active carbon filters (optional)
Auto restart after a power supply black out
Electronic protection against over-pressures
High efficiency rotary compressor
Self-diagnostic functions
R410Aeco
ifeel
3speed
+43°C
-15°C
active carbonfilter
OZONEFRIENDLY
washablefilters
Cooling only
PRODUCT NAME FC752CL3 FC764CL3
FC752CL FC764CL
AE752SCL3 AE764SCL3
5,00 6,50
ABCDEFG A B
E.E.R. 3,23 3,13
715-610-510 890-790-640
l/h 1,8 2,0
n° 3 + Auto/1 3 + Auto/1
49-47-40 51-49-46
44 47
400/3N/50 400/3N/50
1,55 2,08
A 3,20 4,20
775 1040
R410A R410A
6,35(1/4") 6,35(1/4")
12,7(1/2") 15,88(5/8")
m 10 12,5
m 20 30
20 25
m 15 15
m 15 15
Kg 23,5/55 23,5/71
mm 680x900x190 680x900x190
mm 630x830x305 735x940x340
Indoor unit
Outdoor unit
Features Units Cooling Cooling
Cooling capacity kW
Energy label class
(kW/kW)
Air flowrate Indoor (h.-m.-l.) m3/hDehumidification
Fan speeds (Indoor / Outdoor)
Sound pressure Indoor (h.-m.-l.) dB(A)
Sound pressure Outdoor (h.) dB(A)
Power supply V/Ph/Hz
Power input kW
Running consumption
Annual energy cons.-cooling(500h)-Dir. 2002/31/CE kWh
Compressor type Rotary Rotary
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Gas additional charge gr/m
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
ON
OF
ON
OF
FF
AS 71/100/125 CL3
Able to run with an outdoor air temperature up to -15°C
Three-phase (400-3-50 Hz) power supply
Infrared remote control; 24h digital timer;
4-addressing possibility
Double temperature sensor (on the unit and indoor
the remote control)
“I Feel” feature, granting the best comfort conditions
Dry function
Three-speed centrifugal fan by remote control
Special system to avoid condensate dripping from air outlet ribs
Night set-back capability
Usable also without remote cotrol
Four horizontal flap by remote control: swinging
or six fixed positions
Washable filters
Integrated pump for condensate discharge
Auto restart after a power supply black-out
Electronic protection against over-pressures
High efficiency rotary compressor
Self-diagnostic functions
64 www.argoclima.com
R410Aeco
ifeel
3speed
+43°C
-15°C
active carbonfilter
OZONEFRIENDLY
washablefilters
Cooling only
PRODUCT NAME AS71CL3 AS100CL3 AS125CL3
AS71CL AS100CL AS125CLAE71SCL3 AE100SCL3 AE125SCL3
7,80 10,40 14,10ABCDEFG B A
E.E.R. / C.O.P. 3,02 3,21 2,82680-840-1.020 1.320-1.680-1.920 1.320-1.680-1.920
l/h 3,0 3,5 5,0n° 3 + Auto/ 2-3 (Auto) 3 + Auto/ 2-3 (Auto) 3 + Auto/ 2-3 (Auto)
47-45-44 54-51-47 54-51-4748 50 51
400/3N/50 400/3N/50 400/3N/502,58 3,30 5,00
A 5,10 6,60 9,701290 1.650
R410A R410A R410A6,35(1/4") 9,52(3/8") 9,52(3/8")15,88(5/8") 19,05(3/4") 19,05(3/4")
m 7,5 7,5 7,5m 30 40 40m 15 25 25m 15 25 25Kg 22/71 27/104 27/128mm 338x860x860 368x1.150x860 368x1.150x860mm 735x940x340 1.235x940x340 1.235x940x340
Indoor unitOutdoor unitFeatures Units Cooling Cooling Cooling Cooling/Heating capacity kWEnergy label class not under Energy labelling
(kW/kW)Air flowrate Indoor (l.-m.-h.) m3/hDehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.-m.-l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzPower input kWRunning consumptionAnnual energy cons.- cooling (500h)-Dir. 2002/31/CE kWh not under Energy labelling
Compressor type Rotary Rotary ScrollRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor (with grille) / OutdoorNet dimension Indoor (with grille) (H./W./D.)Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
ON
OF
FO
NO
FF
67www.argoclima.com
PAAAA
CCK
AAGG
PAAA
CK
AAG
EE
Package DC Inverter up to 14 kW of
thermal capacity for single and multi
applications, for high-wall, floor/ceiling
or built-in type (cassette and ducted)
AWS 71 PH/H3
PAM DC Inverter technology
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting
cycle to avoid cool air emission in the room
Among controls available for this kind of indoor unit (all optional):
the infrared remote control, equipped with a 24h digital timer
and a temperature sensor granting automatically the best
comfort conditions (“I Feel” feature); a special wired controller
with configuration, diagnostic and weekly timer capabilities
Night set back capability
Dry function
New three-speed tangential fan by remote control, granting a
better and low noise air diffusion
Horizontal flap swinging or to be set to a fixed position
by remote control
Vertical flap by manual control
Washable air filters
Dynamic refrigerant control by DC Inverter compressor and
circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
Auto restart after a power supply black out
Electronic protection against over-pressures
Wide operating range with outdoor air temperatures
up to -15°C in both cooling and heating modes
Single-phase (230/1/50) and Three-phase (400/3/50)
power supply
High efficiency Twin rotary compressor
68 www.argoclima.com
PA
CK
AG
EP
AC
KA
GE
R410Aeco
ifeel 3speed+43°C
-15°C
auto restart
washablefilters
PRODUCT NAME AWS71PH/H3/H3B
AWS71PHAES71PIH/H3/H3B
7,10 (2,2-8,0) 8,00 (2,2-9,0)BTU/h 24.000 27.000
6.100 6.880ABCDEFG B B
E.E.R. / C.O.P. 3,01 3,54m³/h 1.140-1.020-840l/h 4,0n° 3 + Auto / 3 (Auto)
41-37-3449
230/1/50-400/3/502,36 2,261.180 -
R410A9,52(3/8")15,88(5/8")
m 30m 50
40m 50m 30Kg 21/58mm 330x1.140x228mm 780x940x340
Indoor unitOutdoor unitFeatures Units Cooling Heating
Cooling/Heating capacity - nominal (min-max)kW
kcal/hEnergy label class
(kW/kW)Air flowrate Indoor (h.m.l.)DehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.m.l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzRunning consumption kWAnnual energy cons.- cooling mode (500h) - Directive 2002/31/CE kWhCompressor type DCInverter Twin RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeGas additional charge gr/mMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
69www.argoclima.com
ASS 71/100 PH/H3
PAM DC Inverter technology
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting
cycle to avoid cool air emission in the room
Among controls available for this kind of indoor unit
(all optional): the infrared remote control, equipped with
a 24h digital timer and a temperature sensor granting
automatically the best comfort conditions (“I Feel” feature);
a special wired controller with configuration, diagnostic and
weekly timer capabilities
Night set back capability
Dry function
New three-speed centrifugal fan by remote control, granting
a better and low noise air diffusion
Special system to avoid condensate dripping from air
outlet ribs
Four horizontal flaps swinging or to be set on a fixed
position by remote control
Washable filters
Integrated pump for condensate discharge
Dynamic refrigerant control by DC Inverter compressor
and circuit, electronic
Valve and fuzzy logic managed by a powerful
microprocessor
Auto restart after a power supply black out
Electronic protection against over-pressures
Wide operating range with outdoor air temperatures up
to -15°C in both cooling and heating modes
Single-phase (230/1/50) and three-phase (400/3/50)
power supply
High efficiency Twin rotary compressor
R410Aeco
ifeel 3speed+43°C
-15°C
auto restart
washablefilters
PRODUCT NAME ASS71PH/H3/H3B ASS100PH/H3/H3B
ASS71PH ASS100PHAES71PIH/H3/H3B AES100PIH/H3/H3B
7,10 (2,2-8,0) 8,00 (2,2-9,0) 10,00 (2,2-11,2) 11,20 (2,2-12,50)BTU/h 24.000 27.000 34.000 38.000
6.100 6.880 8.600 9.630ABCDEFG A A A A
E.E.R. / C.O.P. 3,33 3,86 3,21 3,78m³/h 1.140-1.020-840 1.920-1.680-1.320l/h 3,6 4,6n°
47-45-41 53-50-4647 49 51 52
230/1/50 - 400/3/50 230/1/50 - 400/3/502,13 2,07 3,12 2,961.065 - 1.560 -
R410A R410A9,52(3/8") 9,52(3/8")15,88(5/8") 15,88(5/8")
m 30 30m 50 50m 30 30m 15 15Kg 28/58 35/65mm 338x860x860 338x1.150x860mm 780x940x340 780x940x340
Indoor unitOutdoor unit (1ph/3ph)Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity - nominal (min-max)kW
kcal/hEnergy label class
(kW/kW)Air flowrate Indoor (h.m.l.)DehumidificationFan speeds (Indoor / Outdoor) 3 + Auto / variable 3 + Auto / variableSound pressure Indoor (h.m.l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply (1ph-3ph) V/Ph/HzRunning consumption kWAnnual energy cons.- cooling mode (500h) - Directive 2002/31/CE kWhCompressor type DCInverter Twin Rotary DCInverter Twin RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
PA
CK
AG
PA
CK
AG
EE
ASS 125 PH/H3B
PAM DC Inverter technology
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting
cycle to avoid cool air emission in the room
Among controls available for this kind of indoor unit
(all optional): the infrared remote control, equipped with a 24h
digital timer and a temperature sensor granting automatically
the best comfort conditions (“I Feel” feature); a special wired
controller with configuration, diagnostic and weekly timer
capabilities
Night set back capability
Dry function
New three-speed centrifugal fan by remote control, granting a
better and low noise air diffusion
Special system to avoid condensate dripping from air
outlet ribs
Four horizontal flaps swinging or to be set on a fixed position
by remote control
Washable filters
Integrated pump for condensate discharge
Dynamic refrigerant control by DC Inverter compressor and
circuit, electronic
Valve and fuzzy logic managed by a powerful microprocessor
Auto restart after a power supply black out
Electronic protection against over-pressures
Wide operating range with outdoor air temperatures
up to -15°C in both cooling and heating modes
Single-phase (230/1/50) and three-phase (400/3/50)
power supply
High efficiency Twin rotary compressor
70 www.argoclima.com
R410Aeco
ifeel 3speed+43°C
-15°C
auto restart
washablefilters
PRODUCT NAME ASS125PH/H3B
ASS125PH
AES125PIH/H3B
12,50 (2,7-14,0) 14,00 (2,7-16,00)
BTU/h 42.500 48.000
10.750 12.040
--
--
GFEDCBA
E.E.R. / C.O.P. 2,81 3,32
023.1-086.1-029.1h/³m
3,6h/l
n°
53-50-46
52/51 53/54
230/1/50 / 400/3/50
3,86/4,45 3,83/4,22
R410A
9,52(3/8")
15,88(5/8")
03m
05m
03m
51m
001/53gK
068x051.1x833mm
0 / 910x940x34043x049x032.1mm
Indoor unit
Outdoor unit (1ph/3ph)
Features Units Cooling Heating
Cooling/Heating capacity - nominal (min-max)
kW
kcal/h
Energy label class
(kW/kW)
Air flowrate Indoor (h.m.l.)
Dehumidification
Fan speeds (Indoor / Outdoor) 3 + Auto / variable
)A(Bd).l.m.h( roodnI erusserp dnuoS
)A(Bd).h( roodtuO erusserp dnuoS
zH/hP/V)hp3-hp1( ylppus rewoP
Running consumption kW
hWk EC/13/2002 evitceriD - )h005( edom gnilooc -.snoc ygrene launnA
Compressor type DCInverter Twin Rotary
Refrigerant type
)"hcni(mmretemaid epip diuqiL
Gas pipe diameter mm(inch")
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
PA
CK
AG
EP
AC
KA
GE
71www.argoclima.com
ADS 71 PH/H3
PAM DC Inverter technology
Three-way duct connection
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting
cycle to avoid cool air emission in the room
Among controls available for this kind of indoor unit
(all optional): the infrared remote control, equipped with
a 24h digital timer and a temperature sensor granting
automatically the best comfort conditions (“I Feel” feature);
a special wired controller with configuration, diagnostic
and weekly timer capabilities
Night set back capability
Dry function
Possibility to increase the Static Pressure
New centrifugal fan, with double static pressure, three speeds
by remote control, granting a better and low noise air diffusion
Integrated pump for condensate discharge
Dynamic refrigerant control by DC Inverter compressor and
circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
Auto restart after a power supply black out
Electronic protection against over-pressures
Wide operating range with outdoor air temperatures
up to -15°C in both cooling and heating modes
Single (230/1/50) and three-phase (400/3/50) power supply
High efficiency Twin rotary compressor
R410Aeco
ifeel 3speed+43°C
-15°C
auto restart
integratedplenum
PRODUCT NAME ADS71PH/H3/H3B
ADS71PHAES71PIH/H3/H3B
7,10 (2,2-8,0) 8,00 (2,2-9,0)BTU/h 24.000 27.000
6.100 6.880ABCDEFG C C
E.E.R. / C.O.P. 2,83 3,351.080-900-780
l/h 3,5mm W.C. 5-10
n°43-39-3634-30-27
47 49230/1/50 - 400/3/50
2,51 2,391.255 -
R410A9,52(3/8")15,88(5/8")
m 30m 50m 30m 15mm 200Kg 32/58mm 310x1.000x630mm 780x940x340
Indoor unitOutdoor unit (1ph/3ph)Features Units Cooling Heating
Cooling/Heating capacity - nominal (min-max)kW
kcal/hEnergy label class
(kW/kW)Air flowrate (h.m.l.) mDehumidificationExternal static pressure (min-max)Fan speeds (Indoor / Outdoor) 3 + Auto / variableSound power Indoor (h.m.l.) dB(A)Sound pressure Indoor (h.m.l.) dB(A)Sound pressure Indoor at ducts exit dB(A) 20Sound pressure Outdoor (h.) dB(A)Power supply (1ph-3ph) V/Ph/HzRunning consumption - nominal (min-max) kWAnnual energy cons.- cooling mode (500h) - Directive 2002/31/CE kWhCompressor type DCInverter Twin RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Ducts diameter Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
PA
CK
AG
PA
CK
AG
EE
ADS 100 PH/H3
PAM DC Inverter technology
Four-way duct connection
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting
cycle to avoid cool air emission in the room
Among controls available for this kind of indoor unit (all optional):
the infrared remote control, equipped with a 24h digital timer
and a temperature sensor granting automatically the best
comfort conditions (“I Feel” feature); a special wired controller
with configuration, diagnostic and weekly timer capabilities
Night set back capability
Dry function
Possibility to increase the Static Pressure
Integrated pump for condensate discharge
New centrifugal fan, with double static pressure, three speeds
by remote control, granting a better and low noise air diffusion
Dynamic refrigerant control by DC Inverter compressor
and circuit, electronic valve and fuzzy logic managed
by a powerful microprocessor
Auto restart after a power supply black out
Electronic protection against over-pressures
Wide operating range with outdoor air temperatures up to
-15°C in both cooling and heating modes
Single (230/1/50) and three-phase (400/3/50) power supply
High efficiency Twin rotary compressor
72 www.argoclima.com
R410Aeco
ifeel 3speed+43°C
-15°C
auto restart
integratedplenum
PRODUCT NAME ADS100PH/H3/H3B
ADS100PHAES100PIH/H3/H3B
10,00 (2,2-11,2) 11,20 (2,2-12,50)BTU/h 34.000 38.000
8.600 9.630ABCDEFG C C
E.E.R. / C.O.P. 2,82 3,391.800-1.560-1.260
l/h 4,2mm W.C. 5-10
n°47-42-4038-33-31
51 52230/1/50
3,55 3,301.775 -
R410A9,52(3/8")15,88(5/8")
m 30m 50m 30m 15mm 200Kg 47/65mm 310x1.480x630mm 780x940x340
Indoor unitOutdoor unit (1ph/3ph)Features Units Cooling Heating
Cooling/Heating capacity - nominal (min-max)kW
kcal/hEnergy label class
(kW/kW)Air flowrate (h.m.l.) mDehumidificationExternal static pressure (min-max)Fan speeds (Indoor / Outdoor) 3 + Auto / variableSound power Indoor (h.m.l.) dB(A)Sound pressure Indoor (h.m.l.) dB(A)Sound pressure Indoor at ducts exit dB(A) 20Sound pressure Outdoor (h.) dB(A)Power supply (1ph-3ph) V/Ph/HzRunning consumption - nominal (min-max) kWAnnual energy cons.- cooling mode (500h) - Directive 2002/31/CE kWhCompressor type DCInverter Twin RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Ducts diameter Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
PA
CK
AG
EP
AC
KA
GE
73www.argoclima.com
ADS 125 PH/H3B
PAM DC Inverter technology
Four-way duct connection
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting
cycle to avoid cool air emission in the room
Among controls available for this kind of indoor unit (all optional):
the infrared remote control, equipped with a 24h digital timer
and a temperature sensor granting automatically the best
comfort conditions (“I Feel” feature); a special wired controller
with configuration, diagnostic and weekly timer capabilities
Night set back capability
Dry function
Possibility to increase the Static Pressure
Integrated pump for condensate discharge
New centrifugal fan, with double static pressure, three speeds
by remote control, granting a better and low noise air diffusion
Dynamic refrigerant control by DC Inverter compressor and
circuit, electronic valve and fuzzy logic managed by
a powerful microprocessor
Auto restart after a power supply black out
Electronic protection against over-pressures
Wide operating range with outdoor air temperatures up to
-15°C in both cooling and heating modes
Single (230/1/50) and three-phase (400/3/50) power supply
High efficiency Twin rotary compressor
R410Aeco
ifeel 3speed+43°C
-15°C
auto restart
integratedplenum
PRODUCT NAME ADS125PH/H3B
ADS125PH
AES125PIH/H3B
12,50 (2,7-14,0) 14,00 (2,7-16,00)
BTU/h 42.500 48.000
10.750 12.040
--GFEDCBA
E.E.R. / C.O.P. 2,87/2,43 3,26/2,81
1.980-1.560-1.320
6,6h/l
01-5.C.W mm
n°
49-46-42
40-37-33
52/51
4,36/5,14 4,29/4,85
53/54
230/1/50 / 400/3/50
2.180/2.570
R410A
9,52(3/8")
15,88(5/8")
03m
05m
03m
51m
002 mm
0/7601-74gK
036x084.1x013mm
0 / 910x940x34043x049x032.1mm
Indoor unit
Outdoor unit (1ph/3ph)
Features Units Cooling Heating
Cooling/Heating capacity - nominal (min-max)
kW
kcal/h
Energy label class
(kW/kW)
Air flowrate (h.m.l.) m3/h
Dehumidification
External static pressure (min-max)
Fan speeds (Indoor / Outdoor) 3 + Auto / variable
)A(Bd).l.m.h( roodnI rewop dnuoS
)A(Bd).l.m.h( roodnI erusserp dnuoS
)A(Bdtixe stcud ta roodnI erusserp dnuoS <20
)A(Bd).h( roodtuO erusserp dnuoS
zH/hP/V)hp3-hp1( ylppus rewoP
Wk)xam-nim( lanimon - noitpmusnoc gninnuR
hWk EC/13/2002 evitceriD - )h005( edom gnilooc -.snoc ygrene launnA
Compressor type DCInverter Twin Rotary
Refrigerant type
)"hcni(mmretemaid epip diuqiL
Gas pipe diameter mm(inch")
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Ducts diameter
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
PA
CK
AG
PA
CK
AG
EE
ACS 71/100 PH/H3
PAM DC Inverter technology
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting
cycle to avoid cool air emission in the room
Among controls available for this kind of indoor unit
(all optional): the infrared remote control, equipped with
a 24h digital timer and a temperature sensor granting
automatically the best comfort conditions (“I Feel” feature);
a special wired controller with configuration, diagnostic
and weekly timer capabilities
Night set back capability
Dry function
Three-speed centrifugal fan by remote control, granting a better
and low noise air diffusion
Horizontal flap swinging or to be set on a fixed position
by remote control, with automatic positioning according
to selected mode (cooling or heating)
Washable air filters
Dynamic refrigerant control by DC Inverter compressor and
circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
Auto restart after a power supply black out
Electronic protection against over-pressures
Wide operating range with outdoor air temperatures up to
-15°C in both cooling and heating modes
Single-phase (230/1/50) and three-phase (400/3/50)
power supply
High efficiency Twin rotary compressor
74 www.argoclima.com
R410Aeco
ifeel 3speed+43°C
-15°C
auto restart
washablefilters
PRODUCT NAME ACS71PH/H3/H3B ACS100PH/H3/H3B
ACS71PH ACS100PHAES71PIH/H3/H3B AES100PIH/H3/H3B
7,10 (2,2-8,0) 8,00 (2,2-9,0) 10,00 (2,2-11,2) 11,20 (2,2-12,50)BTU/h 24.000 27.000 34.000 38.000
6.100 6.880 8.600 9.630ABCDEFG B B B A
E.E.R. / C.O.P. 3,02 3,56 3,04 3,67m³/h 1.098-900-840 1.650-1.380-1.200l/h 3,0 3,9n°
38-36-33 41-38-3547 49 51 52
230/1/50 - 400/3/50 230/1/50 - 400/3/502,35 2,25 3,29 3,671.175 - 1.645 -
R410A R410A9,52(3/8") 9,52(3/8")15,88(5/8") 15,88(5/8")
m 30 30m 50 50m 30 30m 15 15Kg 25/58 33/65mm 210x1.180x680 210x1.595x680mm 780x940x340 780x940x340
Indoor unitOutdoor unit (1ph/3ph)Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity - nominal (min-max)kW
kcal/hEnergy label class
(kW/kW)Air flowrate Indoor (h.m.l.)DehumidificationFan speeds (Indoor / Outdoor) 3 + Auto / variable 3 + Auto / variableSound pressure Indoor (h.m.l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply (1ph-3ph) V/Ph/HzRunning consumption kWAnnual energy cons.- cooling mode (500h) - Directive 2002/31/CE kWhCompressor type DCInverter Twin Rotary DCInverter Twin RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
PA
CK
AG
EP
AC
KA
GE
75www.argoclima.com
ACS 125 PH/H3
PAM DC Inverter technology
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting
cycle to avoid cool air emission in the room
Among controls available for this kind of indoor unit
(all optional): the infrared remote control, equipped with
a 24h digital timer and a temperature sensor granting
automatically the best comfort conditions (“I Feel” feature);
a special wired controller with configuration, diagnostic
and weekly timer capabilities
Night set back capability
Dry function
Three-speed centrifugal fan by remote control, granting
a better and low noise air diffusion
Horizontal flap swinging or to be set on a fixed position
by remote control, with automatic positioning according
to selected mode (cooling or heating)
Washable air filters
Dynamic refrigerant control by DC Inverter compressor
and circuit, electronic valve and fuzzy logic managed
by a powerful microprocessor
Auto restart after a power supply black out
Electronic protection against over-pressures
Wide operating range with outdoor air temperatures up to
-15°C in both cooling and heating modes
Single-phase (230/1/50) and three-phase (400/3/50)
power supply
High efficiency Twin rotary compressor
R410Aeco
ifeel 3speed+43°C
-15°C
auto restart
washablefilters
PRODUCT NAME ACS125PH/H3B
ACS125PH
AES125PIH/AES125PIH3B
12,50 (2,7-14,0) 14,00 (2,7-16,00)
BTU/h 42.500 48.000
10.750 12.040
--GFEDCBA
E.E.R. / C.O.P. 3,03/2,36 3,44/3,15
023.1-065.1-008.1h/³m
6,5h/l
n°
43-40-37
52/51 53/54
230/1/50 / 400/3/50
4,12/5,29 4,07/4,45
2.060/2645 -
R410A
9,52(3/8")
15,88(5/8")
03m
05m
03m
51m
001/33gK
086x595.1x012mm
0 / 910X940X34043x049x032.1mm
Indoor unit
Outdoor unit (1ph/3ph)
Features Units Cooling Heating
Cooling/Heating capacity - nominal (min-max)
kW
kcal/h
Energy label class
(kW/kW)
Air flowrate Indoor (h.m.l.)
Dehumidification
Fan speeds (Indoor / Outdoor) 3 + Auto / variable
)A(Bd).l.m.h( roodnI erusserp dnuoS
)A(Bd).h( roodtuO erusserp dnuoS
zH/hP/V)hp3-hp1( ylppus rewoP
Running consumption kW
hWk EC/13/2002 evitceriD - )h005( edom gnilooc -.snoc ygrene launnA
Compressor type DCInverter Twin Rotary
Refrigerant type
)"hcni(mmretemaid epip diuqiL
Gas pipe diameter mm(inch")
Max. pipe lenght with gas standard charge
Max. pipe lenght with gas additional charge
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Indoor / Outdoor
Net dimension Indoor (H./W./D.)
Net dimension Outdoor (H./W./D.)
The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC
PA
CK
AG
PA
CK
AG
EE
Multipackage DC Inverter
AES 125 PIH/H3Cooling: 12,5 kWHeating: 14 kW
AES 71 PIH/H3(B)Cooling: 7,1 kWHeating: 8 kW
AES 100 PIH/H3(B)Cooling: 10 kWHeating: 11,2 kW
AES 125 PIH/H3BCooling: 12,5 kWHeating: 14 kW
76 www.argoclima.com
OUTDOOR UNIT MODEL AES71PIH/H3/H3B
A B C D A B C D
AWS71PH 7,10 - - - 7,1 (2,2-8,0) 8,00 - - - 8,0 (2,2-9,0)
ASS71PH Cassette 7,10 - - - 7,1 (2,2-8,0) 8,00 - - - 8,0 (2,2-9,0)
ACS71PH 7,10 7,1 (2,2-8,0) 8,00 8,0 (2,2-9,0)
ADS71PH 7,10 - - - 7,1 (2,2-8,0) 8,00 - - - 8,0 (2,2-9,0)AWS36PH 3,55 3,55 - - 7,1 (2,2-8,0) 4,00 4,00 - - 8,0 (2,2-9,0)ASS36PH Cassette 3,55 3,55 - - 7,1 (2,2-8,0) 4,00 4,00 - - 8,0 (2,2-9,0)
ADS36PH 3,55 3,55 - - 7,1 (2,2-8,0) 4,00 4,00 - - 8,0 (2,2-9,0)
FC36PHG 3,55 3,55 - - 7,1 (2,2-8,0) 4,00 4,00 - - 8,0 (2,2-9,0)
OUTDOOR UNIT MODEL AES100PIH/H3/H3B
A B C D A B C D
ASS100PH Cassette 10,00 - - - 10,0 (2,2-11,2) 11,20 - - - 11,2 (2,2-12,5)
ACS100PH 10,00 - - - 10,0 (2,2-11,2) 11,20 - - - 11,2 (2,2-12,5)
ADS100PH 10,00 - - - 10,0 (2,2-11,2) 11,20 - - - 11,2 (2,2-12,5)
AWS56PH 5,00 5,00 - - 10,0 (2,2-11,2) 5,60 5,60 - - 11,2 (2,2-12,5)
ASS56PH Cassette 5,00 5,00 - - 10,0 (2,2-11,2) 5,60 5,60 - - 11,2 (2,2-12,5)
ADS56PH 5,00 5,00 - - 10,0 (2,2-11,2) 5,60 5,60 - - 11,2 (2,2-12,5)
FC56PHG 5,00 5,00 - - 10,0 (2,2-11,2) 5,60 5,60 - - 11,2 (2,2-12,5)AWS36PH 3,55 3,55 3,55 - 10,65 4,00 4,00 4,00 - 12,0 ASS36PH Cassette 3,55 3,55 3,55 - 10,65 4,00 4,00 4,00 - 12,0
ADS36PH 3,55 3,55 3,55 - 10,65 4,00 4,00 4,00 - 12,0
FC36PHG 3,55 3,55 3,55 - 10,65 4,00 4,00 4,00 - 12,0
OUTDOOR UNIT MODEL AES125PIH/H3/H3B
A B C D A B C DASS125PH Cassette 12,50 - - - 12,5 (2,7-14,0) 14,00 - - - 14,0 (2,7-16,0)ACS125PH 12,50 - - - 12,5 (2,7-14,0) 14,00 - - - 14,0 (2,7-16,0)
ADS125PH 12,50 - - - 12,5 (2,7-14,0) 14,00 - - - 14,0 (2,7-16,0)
AWS71PH 6,25 6,25 - - 12,5 (2,7-14,0) 7,00 7,00 - - 14,0 (2,7-16,0)
ASS71PH Cassette 6,25 6,25 - - 12,5 (2,7-14,0) 7,00 7,00 - - 14,0 (2,7-16,0)
ACS71PH 6,25 6,25 - - 12,5 (2,7-14,0) 7,00 7,00 - - 14,0 (2,7-16,0)
ADS71PH 6,25 6,25 - - 12,5 (2,7-14,0) 7,00 7,00 - - 14,0 (2,7-16,0)AWS45PH 4,16 4,16 4,16 - 12,5 (2,7-14,0) 4,66 4,66 4,66 - 14,0 (2,7-16,0)ASS45PH Cassette 4,16 4,16 4,16 - 12,5 (2,7-14,0) 4,66 4,66 4,66 - 14,0 (2,7-16,0)
ADS45PH 4,16 4,16 4,16 - 12,5 (2,7-14,0) 4,66 4,66 4,66 - 14,0 (2,7-16,0)
FC45PHG 4,16 4,16 4,16 - 12,5 (2,7-14,0) 4,66 4,66 4,66 - 14,0 (2,7-16,0)
AWS36PH 3,12 3,12 3,12 3,12 12,5 (2,7-14,0) 3,50 3,50 3,50 3,50 14,0 (2,7-16,0)
ASS36PH Cassette 3,12 3,12 3,12 3,12 12,5 (2,7-14,0) 3,50 3,50 3,50 3,50 14,0 (2,7-16,0)
ADS36PH 3,12 3,12 3,12 3,12 12,5 (2,7-14,0) 3,50 3,50 3,50 3,50 14,0 (2,7-16,0)
FC36PHG 3,12 3,12 3,12 3,12 12,5 (2,7-14,0) 3,50 3,50 3,50 3,50 14,0 (2,7-16,0)
Note n.1
Note n.2
Note n.3
Indoor unit models Type
Cooling Heating
Indoor capacity (kW) Total capacity Indoor capacity (kW) Total capacity
kW kW
Connectable Indoor units
1 unit
High-wall
Underceiling
2 units also
mixed
DuctedHigh-wall
Ducted
Floor/Ceiling
Indoor unit models Type
Cooling Heating
Indoor capacity (kW) Total capacity Indoor capacity (kW) Total capacity
kW kW
Connectable Indoor units
1 unit Underceiling
Ducted
2 units also
mixed
High-wall
Ducted
Floor/Ceiling
3 units also
mixed
High-wall
Ducted
Floor/Ceiling
Indoor unit models Type
Cooling Heating
Indoor capacity (kW) Total capacity Indoor capacity (kW) Total capacity
kW kW
Connectable Indoor units
1 unit Underceiling
Ducted
2 units also
mixed
High-wall
Underceiling
Ducted
3 units
High-wall
Ducted
Floor/Ceiling
4 units also
mixed
High-wall
Ducted
Floor/Ceiling
Indoor units names contain one number identifying their nominal capacity in kW (i.e.: 71=7,1kW=25000 BTU/h)
The Indoor units here indicated have the same caracteristics as the Indoor units used with the MultiSet DCInverter systems described in the following pages; the only difference is the type of pcb installed.
The control systems (wireless, wired, weekly timer, system controller, etc...) are equal to those used for the MultiSet DCInverter systems described in the following pages.
Outdoor/Indoor units Matching
PA
CK
AG
EP
AC
KA
GE
77www.argoclima.com
Multipackage DCI features
Straight cooling and heat pump Package DC Inverter R410A can be set with two,
three or four indoor units operating simultaneously; this type of installation is the best
for big shops, open space offices, restaurants,...
The installation of more indoor units in one only big room allows a better diffusion
of the conditioned air
The MultiPackage DC Inverter R410A control systems allow a sophisticated control
of single and multi-package configurations by zones, with a maximum of 256 indoor
units being managed by one only intelligent controller
In addition to single-Package DC Inverter R410A features, change-over functionality
and Cluster control, both in cooling and heating modes
Two-unit matchings (duo) are realized with a 2-way distribution joint kit
Three-unit matchings (trio) are realized with a 3-way distribution joint kit
Four-unit matchings (quartet) are realized with 3 distribution joint kits (2-way),
in tree configuration (1 > 2 > 4)
Special function during heat pump start-up and defrosting cycle to avoid cool air
emission in the room
“I Feel” feature, granting the best comfort conditions
Night set back capability
All MultiPackage DC Inverter R410A systems may be controlled by infrared remote
control with digital 24h timer and temperature sensor indoor or by a special wired
controller with configuration, diagnostic and weekly timer capabilities;
in the following pages are shown all the MultiPackage DC Inverter R410A
control systems
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve
and fuzzy logic managed by a powerful microprocessor
Auto restart after a power supply black out
Electronic protection against over-pressures
Wide operating range with outdoor air temperatures up to -15°C in both cooling
and heating modes
Single-phase (230/1/50) and Three-phase (400/3/50) power supply thanks to
DC Inverter technology low consumption
Double rotary compressor
HIGH WALL INDOOR UNITS
CASSETTE INDOOR UNITS
CEILING INDOOR UNITS
FLOOR/CEILING INDOOR
UNITS
DUCTED INDOOR UNITS
PA
CK
AG
PA
CK
AG
EE
Pipe lines
78 www.argoclima.com
PIPES LENGHT AND DIFFERENCES BETWEEN UNITS IN DUO,
TRIO AND QUARTET CONFIGURATIONS
PIPES DIAMETER (I.U.)
Duo Trio
L+l1 L+l1, L+l2 L+L1+l1, L+L1+l250
L+l2 L+l3 L+L2+l3, L+L2+l4
l1,l2 l1,l2,l3L1+l1, L1+l2
15L2+l3, L2+l4
Max: L2+l4
10l1-l2
l1-l2l1-l3
(L2+l4)-(L1+l1)l2-l3
-- 10
-- 10l2-l1 l4-l3
H1 30
H1 15
H2 H2, H3, H4 H2, H3, H4, H5, H6, H7 0,5
Description Quartet Lenght (m)
Tubing lenght from the Outdoor unit to the farthest Indoor unit
Tubing lenght after the first distribution
Difference between maximum and minimum tubing lenght ,
after the first distribution
l1>l2l1>l2>l3
Min: L1+l1
Max. tubing lenght difference at distribution joint no. 1 L2>L1 L2-L1
Max. tubing lenght difference at distribution joint no. 2l2>l1 l4>l3
Max. height difference between units (Outdoor on top)
Max. height difference between units (Indoor on top)
Max. height difference between Indoor units
36 45 56 71 100 125
6,35(1/4") 6,35(1/4") 6,35(1/4") 9,52(3/8") 9,52(3/8") 9,52(3/8")
12,7(1/2") 12,7(1/2") 12,7(1/2") 15,88(5/8") 15,88(5/8") 15,88(5/8")
Type capacity of indoor units -->
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
PA
CK
AG
EP
AC
KA
GE
79www.argoclima.com
Indoor units table
Dry
AWS36PH l/h 1,9 3 + Auto mm 285x995x203 kg 12
AWS45PH l/h 1,9 3 + Auto mm 285x995x203 kg 12
AWS56PH l/h 2,1 3 + Auto mm 285x995x203 kg 12
AWS71PH l/h 4,0 3 + Auto mm 330x1.140x228 kg 21
ASS36PH l/h 1,2 3 + Auto mm 273x575x575 kg 16
ASS45PH l/h 2,3 3 + Auto mm 273x575x575 kg 18
ASS56PH l/h 2,3 3 + Auto mm 273x575x575 kg 18
- - - - mm 41x730x730 kg 2,5
l/h 3,6 3 + Auto mm 338x860x860 kg 22
- - - - mm 30x860x860 kg 6
l/h 4,6 3 + Auto mm 338x1150x860 kg 27
l/h 6,3 3 + Auto mm 338x1150x860 kg 27
- - - - mm 30x1150x860 kg 8
ADS36PH l/h 1,5 3 + Auto mm 266x926x571 kg 30
- - - - mm 266x926x200 kg 6
ADS45PH l/h 2,3 3 + Auto mm 266x1132x571 kg 35
ADS56PH l/h 2,3 3 + Auto mm 266x1132x571 kg 35
- - - - mm 266x1132x200 kg 7,5
ADS71PH l/h 3,5 3 + Auto mm 310x1000x630 kg 32
ADS100PH l/h 4,2 3 + Auto mm 310x1480x630 kg 47
ADS125PH l/h 6,6 3 + Auto mm 310x1480x630 kg 47
FC36PHG l/h 1,3 3 + Auto mm 680x900x190 kg 23,5
FC45PHG l/h 2,3 3 + Auto mm 680x900x190 kg 23,5
FC56PHG l/h 2,3 3 + Auto mm 680x900x190 kg 23,5
ACS71PH l/h 3,0 3 + Auto mm 210x1180x680 kg 25
ACS100PH l/h 3,9 3 + Auto mm 210x1595x680 kg 33
ACS125PH l/h 5,6 3 + Auto mm 210x1595x680 kg 35
Hi-wall units
Air flowrate (h.m.l.) Fan speeds Sound pressure(h.m.l.) Dimension (HxWxD) Net weight
m3/h 720-600-420 dB(A) 35-31-27
m3/h 720-600-420 dB(A) 35-31-27
m3/h 780-660-480 dB(A) 38-34-30
m3/h 1140-1020-840 dB(A) 41-37-34
Cassette units
m3/h 700-600-500 dB(A) 43-40-37
m3/h 750-630-530 dB(A) 44-40-37
m3/h 750-630-530 dB(A) 44-40-37
ASGM0918 (grille)
ASS71PH (with grille) m3/h 1140-1020-840 dB(A) 47-45-41
ASG0025E (grille)
ASS100PH (with grille) m3/h 1920-1680-1320 dB(A) 53-50-46
ASS125PH (with grille) m3/h 1920-1680-1320 dB(A) 53-50-46
ASG3648E (grille)
Ducted units
m3/h 600-510-440 dB(A) 45-43-40
2-way duct (200 mm each) Plenum
m3/h 875-600-400 dB(A) 45-38-33
m3/h 875-600-400 dB(A) 45-38-33
3-way duct (200 mm each) Plenum
m3/h 1080-900-780 dB(A) 34-30-27
m3/h 1800-1560-1260 dB(A) 38-33-31
m3/h 1980-1560-1320 dB(A) 40-37-33
Floor/ceiling units
m3/h 700-590-500 dB(A) 47-43-38
m3/h 830-760-665 dB(A) 52-49-46
m3/h 830-760-665 dB(A) 52-49-46
Ceiling units
m3/h 1098-900-840 dB(A)38-36-33
m3/h 1650-1380-1200 dB(A) 41-38-35
m3/h 1800-1560-1320 dB(A) 43-40-37
NB: For the indoor units capacity see the matching table.P
AC
KA
GP
AC
KA
GEE
80 www.argoclima.com
Controls & accessories
www.argoclima.com
Schedule timerSchedule timer able to manage up to 64 indoor units with customized programming of all
features, on/off cycles, etc.
Simplified wired remote controllerSimplified wired remote controller to be used with the full range of indoor units; it controls
all the main features
Standard wired remote controllerStandard wired remote controller with full features control, self-diagnostic and centralized
programming capabilities
Infrared remote controller with receiverInfrared remote controller to be used, in matching with a special infrared receiver, with the
full range of indoor units; it shows the operation status of the air-conditioner
Infrared remote controller / i.u. ACInfrared remote controller to be used with underceiling indoor units
Infrared remote controller / i.u. AS-FC
Infrared remote controller to be used with cassette and floor/ceiling indoor units
Infrared remote controller / i.u. HIGH-WALLInfrared remote controller to be used with high-wall indoor units
Remote sensorRemote sensor to be used with the full range of indoor units to detect the room temperature
when no remote controller sensor or body sensor is used: suggested for air-conditioner
systems without remote controller
PA
CK
AG
EP
AC
KA
GE
81www.argoclima.comwww.argoclima.com
Optional distribution joint kit
DDVI 16 Capacity after distribution joint is 16.0 kW or less
DTVP Capacity after distribution joint is 28.0 kW or less
PA
CK
AG
PA
CK
AG
EE
83www.argoclima.com
Two/Three way modular systems
for installations up to 135 kW/48HP
max 3 outdoor units & 40 indoor units
VR
VR
FF
Two/T
for ins
max 3
Multiset DC Inverter systems demand the respect of precise rules in the engineering of a refrigerant circuit
Argoclima gives to system engineers all support and accessories necessary for a correct implementation of an air conditioner system.
Engineering and design software Distribution kits Expansion valves with electronic control Accessories to change the air with outside
Our organization of Argo technicians and engineers is at Your disposal for the development of projects, the realization of CAD designs, the test/start of the system and the after-sale technical service.
Argoclima Multiset design support software
Multiset V.R.F. DC Inverter
84 www.argoclima.com
VR
FV
RF
85www.argoclima.com
Multiset Vrf Systems Advantages
FOR THOSE WHO PURCHASE AND WHO INSTALL
COST REDUCTION The system uses only two pipes (three in case of systems with heat recovery): the cost and installation time are thus reduced.
FOR THOSE WHO USE AND WHO MAKE MAINTENANCE
CUSTOMIZED SELECTION: The user can select at will the environmental conditions of each area or room to obtain an optimal climate.
A COMFORTABLE ENVIRONMENT: The temperature control reduces the time necessary to achieve the desired conditions, keeping them steadily.
HIGH PERFORMANCE ROTARY COMPRESSORS: The advanced design of the compressors together with the LONG-LIFE system, using cyclic compressors in multiple installations, offer extended service life.
SELF-DIAGNOSIS FUNCTION: In case of failure, both the remote devices and the outdoor units provide the information necessary to become aware of the location and characteristics of the failure, reducing repair and maintenance time.
EASY USE OF THE REMOTE CONTROL: Remote Control allows you to obtain very easily maximum performances from each indoor unit. You can easily select the operation mode (dry/cooling/heating/ventilation), the desired temperature, the air flow volume and direction, etc.
EASY INSTALLATION OF CONTROL SYSTEM: The control system uses a transmission circuit formed by two wires without polarity; in this way, you avoid errors and significantly reduces the time required for the connection.
MINIMAL INVASIVENESS IN THE BUILDING: Pipes small sizes don’t allow to excessively pollute the building in which the system will be installed. This advantage is particularly important in case of structures already existing or under renovation.
INSTALLATION TIME REDUCTION: The accessories for connecting pipes and the modular type of mounting facilitate and accelerate the time required for installation.
VERSATILE CONTROL SYSTEM: The control system allows numerous combinations of individual control, group control and system control.
EASY MODIFICATIONS AND IMPLEMENTATIONS: If it was intended in the design phase, you can expand the system with the addition of indoor and outdoor units in a simple and practical way.
FLEXIBILE MANAGEMENT: The system can have a power ratio between indoor and outdoor units from 50% to 130%.
FOR THOSE WHO DESIGN AND WHO PROPOSE
CONSIDERABLE FLEXIBILITY OF THE TRACK: The high length of refrigerant pipes between indoor and outdoor units makes easier the installation adjustment to the configuration of the building; also the large distances between indoor and outdoor units allow to easily choose the best location for the condensing units.
VR
VR
FF
Mini Multiset V.R.F. DC
AES04MMIH/H3
AES05MMIH/H3
AES06MMIH/H3
Cooling: 11,2 kWHeating: 12,5 kWCooling: 14 kWHeating: 16 kWCooling: 15,5 kWHeating: 17,6 kW
The Mini Multiset V.R.F. DC Inverter System is the new frontier of
technology, specifically thought for residential and light commer-
cial applications
DCI High efficiency DC Inverter Compressor, circuit DCI PAM
(Dc Inverter Pulse Amplitude modulation), maximum of 9 indoor
units connectable to 1 outdoor unit (model AES06MMIH). DC
Inverter Fan
V.R.F. Variable Refrigerant Flow: continuous regulation of the
refrigerant flow rate in the circuit of an air conditioning system
able to give the best in term of comfort, with very high efficiency
levels (E.E.R. up to 4,06 - model AES04MMIH)
R410A The most ecological and efficient refrigerant available for
air conditioning systems of this level of thermal capacity
COMPACT Reduced dimensions of the outdoor unit
WIDE RANGE Three sizes available: 4-5-6 HP
230/400 VOLT Single-phase (230/1/50) and Three-phase
(400/3/50) power supply
150 m Refrigerant circuit of a maximum length of 150 m, to
be realized with a big save of time thanks to the reduced pipe
dimension and to the simple tree structure that makes widening
easy, not requiring any installation of expensive concentrator
apparatus
LAN (Local Area Network) For the interconnection of all the
indoor/outdoor units and the system controls, realized with two
wiring cables without polarization; the intelligent controllers are
able to auto set all the units, simplifying and reducing to minimum
the time-to-start
SILENCE Low sound levels thanks to the special fans and to the
careful study of the air movements in suction
WIDE LIMITS The wide range of outdoor air temperature
supported allows the operation even in extreme conditions:
from -10°C to +43°C in cooling mode from -20°C to +15°C in
heating mode
MATCHIN & CONTROLS Indoor units, controllers (all optional)
and accessories are the same as those of 2 and 3 way Multiset
V.R.F.DCI
86 www.argoclima.com
VR
FV
RF
87www.argoclima.com
Mini Multiset V.R.F. DC
AES04MMIH/H3 AES05MMIH/H3 AES06MMIH/H3
HP 4 5 611,2 12,5 14,0 16,0 15,5 17,6
BTU/h 38.200 42.700 47.800 54.600 52.900 60.0009.630 10.750 12.040 13.760 13.330 15.140
E.E.R. / C.O.P. 4,06 4,34 3,66 4,1 3,39 3,84m³/h 6.000 6.000 6.000
51/48 51/48 52/49230/1/50 - 400/3/50 230/1/50 - 400/3/50 230/1/50 - 400/3/502,76 2,88 3,83 3,90 4,57 4,58
R410A R410A R410A9,52(3/8") 9,52(3/8") 9,52(3/8")15,88(5/8") 15,88(5/8") 19,05 (3/4")
no. 6 8 9m 150 150 150Kg 3,5 3,5 3,5m 15 15 15m 50 50 50m 40 40 40Kg 104 104 104mm 1.200x940x340 1.200x940x340 1.200x940x341
INVERTER outdoor units
Features units Cooling Heating Cooling Heating Cooling Heating
Cooling/Heating capacitykW
kcal/h(kW/kW)
Air flowrate (h.)Sound pressure (normal/silent mode) dB(A)Power supply V/Ph/HzRunning consumption kWCompressor type DC Inverter DC Inverter DC InverterRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. number of connectable indoor unitsMax. pipe lenght Gas standard chargeMax. distance between indoor unitsMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight OutdoorNet dimension Outdoor (H./W./D.)
VR
VR
FF
Multiset V.R.F. DC
88 www.argoclima.com
DCI + SAC DC Inverter Compressor + Scroll AC Compressor, the
perfect matching for a high efficiency system with capacity up to 48HP,
automatically modulated by the DCI PAM (Dc Inverter Pulse Amplitude
modulation) circuit on a maximum of 40 indoor units connected.
V.R.F. Variable Refrigerant Flow: continuous regulation of the
refrigerant flow rate in the circuit of an air conditioning system able to
give the best in term of comfort, with very high efficiency levels (COP
up to 4,09).
R410A The most ecological and efficient refrigerant available for air
conditioning systems of this level of thermal capacity.
TWO WAY Two-way system with possibility of condensing and
indoor units increase thanks to the simple tree refrigerant circuit.
THREE WAY New three-way solution with heat recovery, giving the
possibility of a simultaneous independent operation in cooling and/or
heating modes of each indoor unit.
HFC= -21% Reduction of the total refrigerant volume of about 21%
in comparison with the previous systems.
300 m Refrigerant circuit of a maximum length of 300 m, to be realized
with a big save of time thanks to the reduced pipe dimension and to
the simple tree structure that makes widening easy, not requiring any
installation of expensive concentrator apparatus.
LAN (Local Area Network) for the interconnection of all the indoor/
outdoor units and the system controls, realized with two wiring cables
without polarization; the intelligent controllers are able to auto set all
the units, simplifying and reducing to minimum the time-to-start.
LONG LIFE A special electronic system controls the operating cycles
of the compressors, distributing the load and extending the efficiency
in the time.
BACK UP The system is able to activate the automatic back-up of the condensing units in error or stopped; the sophisticated control
system compensates the bad operation of the blocked outdoor unit, distributing the thermal power to the other outdoor units of the
multiple configuration system.
SILENCE For the first time the sound levels are lower than 52 dB; thanks to the special fans and to the careful study of the air
movements in suction, the sound levels have been reduced of more than 4 dB in comparison with the previous models.
WIDE RANGE The wide range of outdoor air temperature supported allows the operation even in extreme conditions:
from -10°C to +43°C in cooling mode
from -20°C to +15°C in heating mode
FREE PLACE The condensing units in multiple configuration can be installed at a distance of only 10 cm or very far one from the other,
even on different stages of the building; this feature makes the system more adaptable to the various circumstances.
VR
FV
RF
89www.argoclima.com
Outdoor Units 2-Way Systems
Main features:
- compactness, making units easier to position;
- smaller pipe works, making material costs lower;
- flexibility of installation;
- high efficiency (C.O.P. at the top of the range: 3,90 average
cooling/heating for the 8HP units)
- reduced life cycle costs;
- accurate capacity control;
- possibility to choose among a wide range of control options.
Maximum number of Outdoor units connectable: 3.
Maximum total power of the system: 135 kW (48 HP).
Maximum number of Indoor units connectable: 40.
Twin Rotary DC Inverter compressor, highly efficient at low
rotation frequencies.
R410A HFC refrigerant.
Fan with direct current motor that allows a consumption reduction
of about 50% and a speed modulation up to 16 steps in spite
of the usual 4 steps of the alternate current motors; this performance
increases the efficiency of the thermodynamic system which is
able to best adapt to the variations of temperature and thermal load
of the rooms.
The use of a special oil sensor allows, for the first time in the world,
to keep under control the lubrification of the mechanical parts of the
compressor.
Special air intakes and Double Chamber construction technology
allowed to unify the dimensions of the units, making easier the closing
up for multiple installations in which two units can be placed at
a distance of only 10 cm one from the other, the smaller distance
available.
Low sound level thanks to a special fan made of resin and a particular
resin grille, designed and used for these units in order to minimize
air pressure drops.
New high efficiency Cross-Arranged heat exchanger with three-way
suction, divided in two sections with double control of defrosting cycle.
Pressure control automatic and by software on PC.
Pipe connection indoor the unit frame through a special space to
be closed back when the installation is finished.
Equipped with Fault-Tolerant system granting in multiple installations the operation of the air conditioning system also in case
of total stop of one condensing unit.
Support to Long-Life system that, in multiple installations, allows a cyclic use of the condensing units, granting a balance
of the compressors activity.
Wide range of outdoor air temperature: from -10°C to +43°C in cooling mode and from -20°C to +15°C in heating mode.
Maximum length of the refrigerant circuit extended to 300 m.
The refrigerant circuit doesn’t require distribution apparatus downstream of the unit as it can be realized with a tree structure using
only the special distributor accessories; this feature facilitates any type of system widening, by adding both outdoor and indoor units.
Three-phase auto sense power supply 380-415/3N/50Hz.
VR
VR
FF
Technical data
90 www.argoclima.com
AES08MI2HA AES10MI2HA AES12MI2HA
22,40 / 25,00 28,00 / 31,50 33,50 / 37,50
E.E.R. / C.O.P. 3,74 / 4,05 3,54 / 4,06 3,50 / 3,91
m³/h 9.000 9.600 10.800
54,5 / 51,5 55 / 52 56 / 53
65,5 66,5 67,5
400/3N/50 400/3N/50 400/3N/50
5,99 / 6,17 7,90 / 7,75 9,58 / 9,60
A 9,20 / 9,50 12,30 / 12,00 14,90 /14,90
R410A R410A R410A
9,52(3/8") 9,52(3/8") 12,70(1/2")
19,05(3/4") 22,22(7/8") 25,40(1")
6,35(1/4") 6,35(1/4") 6,35(1/4")
m 300 300 300
Kg 12 12 12
°C
% 50 - 130 50 - 130 50 - 130
N° 13 16 19
m 50 50 50
m 40 40 40
Kg 245 295 295
mm 1.887x890(+60)x890 1.887x890(+60)x890 1.887x890(+60)x890
2-way INVERTER OUTDOOR UNIT
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Running consumption (cooling/heating) kW
Running current
Compressor type Twin Rotary DCI (N°1) Twin Rotary DCI+Scroll(N°2) Twin Rotary DCI+Scroll(N°2)
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter (suction) mm(inch")
Balance pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
AES14MI2HA AES16MI2HA
40,00 / 45,00 45,00 / 50,00
E.E.R. / C.O.P. 3,45 / 3,91 3,38 / 3,79
m³/h 12.000 13.200
61 / 58 62 / 59
71,5 72
400/3N/50 400/3N/50
11,60 / 11,50 13,30 / 13,20
A 18,60 /18,50 21,30 /21,20
R410A R410A
12,70(1/2") 12,70(1/2")
25,40(1") 28,58(1-1/8")
6,35(1/4") 6,35(1/4")
m 300 300
Kg 13 13
°C
% 50 - 130 50 - 130
N° 23 26
m 50 50
m 40 40
Kg 345 345
mm 1.887x890(+60)x890 1.887x890(+60)x890
2-way INVERTER OUTDOOR UNIT
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Running consumption (cooling/heating) kW
Running current
Compressor type Twin Rotary DCI+Scroll(N°3) Twin Rotary DCI+Scroll(N°3)
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter (suction) mm(inch")
Balance pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 -10
Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
VR
FV
RF
91www.argoclima.com
Outdoor units matchings - technical data
CAPACITY CLASSES (HP) 18 HP 20 HP 22 HP
AES10+AES08 MI2HA AES10+AES10 MI2HA AES12+AES10 MI2HA
50,40 / 56,50 56,00 / 63,00 61,50 / 69,00
E.E.R. / C.O.P. 3,63 / 4,06 3,54 / 3,80 3,51 / 3,97
m³/h 9.600 + 9.000 9.600 x 2 10.800 + 9.600
58 / 55 58 / 55 58,5 / 55,5
69 69,5 69,5
400/3N/50 400/3N/50 400/3N/50
13,9 / 13,9 15,8 / 15,5 17,5 / 17,4
A 21,60 / 21,60 24,7 / 24,2 27,2 / 27,0
R410A R410A R410A
15,88(5/8") 15,88(5/8") 15,88(5/8")
28,58(1-1/8") 28,58(1-1/8") 28,58(1-1/8")
6,35(1/4") 6,35(1/4") 6,35(1/4")
m 300 300 300
Kg 12,0 x 2 12,0 x 2 12,0 x 2
°C
% 50-130 50-130 50-130
N° 29 33 36
Kg 295 + 245 295 x 2 295 x 2
mm 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60)
Outdoor units matchings
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll
Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve
Refrigerant type
Liquid pipe diameter after 1° distributor kit mm(inch")
Gas pipe diameter after 1° distributor kit mm(inch")
Diameter of balancing pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
CAPACITY CLASSES (HP) 24 HP 26 HP 28 HP
AES14+AES10 MI2HA AES16+AES10 MI2HA AES16+AES12 MI2HA
68,00 / 76,50 73,00 / 81,50 78,50 / 87,50
E.E.R. / C.O.P. 3,49 / 3,96 3,44 / 3,88 3,43 / 3,84
m³/h 12.000 + 9.600 13.200 + 9.600 13.200 + 10.800
62 / 59 63 / 60 63 / 60
72,5 73 73,5
400/3N/50 400/3N/50 400/3N/50
19,5 / 19,3 21,2 / 21,0 22,9 / 22,8
A 30,8 / 30,4 33,6 / 33,3 36,3 / 36,2
R410A R410A R410A
15,88(5/8") 19,05(3/4") 19,05(3/4")
28,58(1-1/8") 31,75(1-1/4") 31,75(1-1/4")
6,35(1/4") 6,35(1/4") 6,35(1/4")
m 300 300 300
Kg 13,0 + 12,0 13,0 + 12,0 13,0 + 12,0
°C
% 50-130 50-130 50-130
N° 40 40 40
Kg 345 + 295 345 + 295 345 + 295
mm 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60)
Outdoor units matchings
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll
Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve
Refrigerant type
Liquid pipe diameter after 1° distributor kit mm(inch")
Gas pipe diameter after 1° distributor kit mm(inch")
Diameter of balancing pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
CAPACITY CLASSES (HP) 30 HP 32 HP 34 HP
AES16+AES14 MI2HA AES16+AES16 MI2HA AES 14+10+10 MI2HA
85,00 / 95,00 90,00 / 100,00 96,00 / 108,00
E.E.R. / C.O.P. 3,41 / 3,85 3,38 / 3,79 3,50 / 4,00
m³/h 13.200 + 12.000 13.200 x 2 12.000 + 9.600 x 2
64,5 / 61,5 65 / 62 63 / 60
74,5 75 73,5
400/3N/50 400/3N/50 400/3N/50
24,9 / 24,7 26,6 / 26,4 27,4 / 27,0
A 39,9 / 39,6 42,7 / 42,3 43,1 / 42,5
R410A R410A R410A
19,05(3/4") 19,05(3/4") 19,05(3/4")
31,75(1-1/4") 31,75(1-1/4") 31,75(1-1/4")
6,35(1/4") 6,35(1/4") 6,35(1/4")
m 300 300 300
Kg 13,0 x 2 13,0 x 2 13,0+12,0 x 2
°C
% 50-130 50-130 50-130
N° 40 40 40
Kg 345 x 2 345 x 2 345 + 295 x 2
mm 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x2.870x890(+60)
Outdoor units matchings
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll
Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve
Refrigerant type
Liquid pipe diameter after 1° distributor kit mm(inch")
Gas pipe diameter after 1° distributor kit mm(inch")
Diameter of balancing pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
VR
VR
FF
Outdoor units matchings - technical data
92 www.argoclima.com
CAPACITY CLASSES (HP) 36 HP 38 HP 40 HP
AES 16+10+10 MI2HA AES 16+12+10 MI2HA AES 16+14+10 MI2HA
101,00 / 113,00 107,00 / 119,00 113,00 / 127,00
E.E.R. / C.O.P. 3,47 / 3,94 3,47 / 3,68 3,45 / 3,91
m³/h 13.200 + 9.600 x 2 13.200 +10.800 + 9.600 13.200 +12.000 + 9.600
63,5 / 60,5 63,5 / 60,5 65 / 62
74 74,5 75
400/3N/50 400/3N/50 400/3N/50
29,1 / 28,7 30,8 / 30,6 32,8 / 32,5
A 45,8 / 45,2 48,0 / 48,0 52,0 / 52,0
R410A R410A R410A
19,05(3/4") 19,05(3/4") 19,05(3/4")
38,10(1-1/2") 38,10(1-1/2") 38,10(1-1/2")
6,35(1/4") 6,35(1/4") 6,35(1/4")
m 300 300 300
Kg 13,0+12,0 x 2 13,0+12,0 x 2 13,0 x 2+12,0
°C
% 50-130 50-130 50-130
N° 40 40 40
Kg 345 + 295 x 2 345 + 295 x 2 345 x 2 + 295
mm 1.887x2.870x890(+60) 1.887x2.870x890(+60) 1.887x2.870x890(+60)
Outdoor units matchings
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll
Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve
Refrigerant type
Liquid pipe diameter after 1° distributor kit mm(inch")
Gas pipe diameter after 1° distributor kit mm(inch")
Diameter of balancing pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
CAPACITY CLASSES (HP) 42 HP 44 HP
AES 16+16+10 MI2HA AES 16+16+12 MI2HA
118,00 / 132,00 124,00 / 138,00
E.E.R. / C.O.P. 3,42 / 3,86 3,43 / 3,83
m³/h 13.200 x 2 + 9.600 13.200 x2 + 10.800
65,5 / 62,5 65,5 / 62,5
75,5 76
400/3N/50 400/3N/50
34,5 / 34,2 36,2 / 36,0
A 55,0 / 54,0 57,0 / 57,0
R410A R410A
19,05(3/4") 19,05(3/4")
38,10(1-1/2") 38,10(1-1/2")
6,35(1/4") 6,35(1/4")
m 300 300
Kg 13,0 x 2+12,0 13,0 x 2+12,0
°C
% 50-130 50-130
N° 40 40
Kg 345 x 2 + 295 345 x 2 + 295
mm 1.887x2.870x890(+60) 1.887x2.870x890(+60)
Outdoor units matchings
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary+Scroll Twin Rotary+Scroll
Refrigerant control Electr. Exp. Valve Electr. Exp. Valve
Refrigerant type
Liquid pipe diameter after 1° distributor kit mm(inch")
Gas pipe diameter after 1° distributor kit mm(inch")
Diameter of balancing pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
CAPACITY CLASSES (HP) 46 HP 48 HP
AES 16+16+14 MI2HA AES 16+16+16 MI2HA
130,00 / 145,00 135,00 / 150,00
E.E.R. / C.O.P. 3,40 / 3,83 3,38 / 3,79
m³/h 13.200 x 2 + 12.000 13.200 x 3
66,5 / 63,5 67,0 / 64,0
76,5 77
400/3N/50 400/3N/50
38,2 / 37,9 39,9 / 39,6
A 61,0 / 61,0 64,0 / 64,0
R410A R410A
19,05(3/4") 19,05(3/4")
38,10(1-1/2") 38,10(1-1/2")
6,35(1/4") 6,35(1/4")
m 300 300
Kg 13,0 x 3 13,0 x 3
°C
% 50-130 50-130
N° 40 40
Kg 345 x 3 345 x 3
mm 1.887x2.870x890(+60) 1.887x2.870x890(+60)
Outdoor units matchings
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary+Scroll Twin Rotary+Scroll
Refrigerant control Electr. Exp. Valve Electr. Exp. Valve
Refrigerant type
Liquid pipe diameter after 1° distributor kit mm(inch")
Gas pipe diameter after 1° distributor kit mm(inch")
Diameter of balancing pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
VR
FV
RF
93www.argoclima.com
Outdoor Units 3-Way Systems
Main features:
Automatic change-over between cooling and heating modes for
each indoor unit; this feature, based on the three-way technology
with heat recovery, allows a fully independent operation of each
indoor unit.
R410A HFC refrigerant.
Twin Rotary DC Inverter compressor, highly efficient at low rotation
frequencies, matching with a Scroll Constant-Speed compressor .
Fan with direct current motor that allows a consumption reduction
of about 50% and a speed modulation up to 16 steps in spite of
the usual 4 steps of the alternate current motors; this performance
increases the efficiency of the thermodynamic system which
is able to best adapt to the variations of temperature and thermal
load of the rooms .
The use of a special oil sensor allows, for the first time in the
world,to keep under control the lubrification of the mechanical
parts of the compressor.
Special air intakes and Double Chamber construction technology
allowed to unify the dimensions of the units, making easy
the closing up for multiple installations in which two units can
be placed at a distance of only 10 cm one from the other,
the smaller distance available.
Low sound level thanks to a special fan made of resin and
a particular resin grille, designed and used for these units in order
to minimize air pressure drops.
New high efficiency Cross-Arranged heat exchanger with
three-way suction, divided in two sections with double control
of defrosting cycle.
Pressure control automatic and by software on PC.
Pipe connection indoor the unit frame through a special space to
be closed back when the installation is finished.
Equipped with Fault-Tolerant system granting in multiple
installations the operation of the air conditioning system also
in case of total stop of one condensing unit.
Support to Long-Life system that, in multiple installations,
allows a cyclic use of the condensing units, granting a balance
of the compressors activity.
“On Demand” feature allows to best use the characteristics of DC Inverter technology, setting three different levels of electric power
on which are automatically based the control microprocessors so that to achieve the maximum performances with reduction of
electric consumption.
Extra range of outdoor air temperature: from -10°C to +43°C in cooling mode and from -20°C to +15°C in heating mode.
Maximum length of the refrigerant circuit extended to 300 m.
The refrigerant circuit doesn’t require distribution apparatus downstream of the unit as it can be realized with a tree structure using
only the special distributor accessories; this feature facilitates any type of system widening, by adding both outdoor and indoor units.
Three-phase auto sense power supply 380-415/3N/50Hz.
VR
VR
FF
Technical data
94 www.argoclima.com
AES08MI3H AES10MI3H AES12MI3H
22,40 / 25,00 28,00 / 31,50 33,50 / 37,50
E.E.R. / C.O.P. 3,78 / 4,09 3,45 / 3,95 3,41 / 3,81
m³/h 9.000 9.600 10.800
54,5/51,5 55/52 56/53
65,5 66 67
400/3N/50 400/3N/50 400/3N/50
5,93 / 6,11 8,12 / 7,97 9,82 / 9,84
A 9,20 / 9,50 12,30 / 12,0 14,9 / 14,9
R410A R410A R410A
9,52(3/8") 9,52(3/8") 12,70(1/2")
19,05(3/4") 22,22(7/8") 25,40(1")
15,88(5/8") 19,05(3/4") 19,05(3/4")
6,35(1/4") 6,35(1/4") 6,35(1/4")
m 300 300 300
Kg 12 12 12
°C
% 50 - 130 50 - 130 50 - 130
no. 13 16 19
m 50 50 50
m 40 40 40
Kg 290 290 290
mm 1.887x890x890(+60) 1.887x890x890(+60) 1.887x890x890(+60)
AES14MI3H AES16MI3H
40,00 / 45,00 45,00 /50,00
E.E.R. / C.O.P. 3,45 / 3,91 3,38 / 3,79
m³/h 12.000 13.200
60/57 61/58
71 72
400/3N/50 400/3N/50
11,6 /11,5 13,3 /13,2
A 19,0 / 18,9 21,8 / 21,6
R410A R410A
12,70(1/2") 12,70(1/2")
25,40(1") 28,58(1-1/8")
22,22(7/8") 22,22(7/8")
6,35(1/4") 6,35(1/4")
m 300 300
Kg 15 15
°C
% 50 - 130 50 - 130
no. 23 26
m 50 50
m 40 40
Kg 350 350
mm 1.887x890x890(+60) 1.887x890x890(+60)
3-way INVERTER OUTDOOR UNITS
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary DCInv.+ Scroll CS Twin Rotary DCInv.+ Scroll CS Twin Rotary DCInv.+ Scroll CS
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter (suction) mm(inch")
Gas pipe diameter (discharge) mm(inch")
Balance pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
3-way INVERTER OUTDOOR UNITS
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary DCInv.+ Scroll CS Twin Rotary DCInv.+ Scroll CS
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter (suction) mm(inch")
Gas pipe diameter (discharge) mm(inch")
Balance pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Max. height between units (Outdoor on top)
Max. height between units (Indoor on top)
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
VR
FV
RF
95www.argoclima.com
Outdoor units matchings - technical data
CAPACITY CLASSES (HP) 18 HP 20 HP 22 HP 24 HP
AES 10+08 MI3H AES 10+10 MI3H AES 12+10 MI3H AES 14+10 MI3H
50,40 / 56,50 56,00 / 63,00 61,50 / 69,00 68,00 / 76,50
E.E.R. / C.O.P. 3,57 / 4,01 3,46 / 3,96 3,44 / 3,88 3,45 / 3,92
m³/h 9.600 + 9.000 9.600 x 2 10.800 + 9.600 12.000 + 9.600
58 / 55 58 / 55 58,5 / 55,5 58 / 55
69 69 69,5 72,5
400/3N/50 400/3N/50 400/3N/50 400/3N/50
14,1 / 14,1 16,2 / 15,9 17,9 / 17,8 19,7 / 19,5
A 22,6 / 22,6 26,0 / 25,5 28,7 / 28,5 31,9 / 31,6
R410A R410A R410A R410A
15,88(5/8") 15,88(5/8") 15,88(5/8") 15,88(5/8")
28,58(1-1/8") 28,58(1-1/8") 28,58(1-1/8") 28,58(1-1/8")
22,22((7/8") 22,22((7/8") 25,4(1") 25,4(1")
9,52(3/8") 9,52(3/8") 9,52(3/8") 9,52(3/8")
m 300 300 300 300
Kg 12,0 x 2 12,0 x 2 12,0 x 2 13,0 + 12,0
°C
% 50 - 130 50 - 130 50 - 130 50 - 130
N° 29 33 36 40
Kg 295 + 245 295 x 2 295 x 2 345 + 295
mm 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60)
CAPACITY CLASSES (HP) 26 HP 28 HP 30 HP 32 HP
AES 16+10 MI3H AES 16+12 MI3H AES 16+14 MI3H AES 16+16 MI3H
73,00 / 81,50 78,50 / 87,50 85,00 / 95,00 90,00 / 100,00
E.E.R. / C.O.P. 3,41 / 3,84 3,40 / 3,80 3,41 / 3,85 3,38 / 3,79
m³/h 13.200 + 9.600 13.200 + 10.800 13.200 + 12.000 13.200 x 2
60 / 57 60,5 / 57,5 61 / 58 61,5 / 58,5
73 73,5 74,5 75
400/3N/50 400/3N/50 400/3N/50 400/3N/50
21,4 / 21,2 23,1 / 23,0 24,9 / 24,7 26,6 / 26,4
A 34,7 / 34,4 37,5 / 37,3 40,8 / 40,5 43,6 / 43,3
R410A R410A R410A R410A
19,05(3/4") 19,05(3/4") 19,05(3/4") 19,05(3/4")
28,58(1-1/8") 1-3/8" 1-3/8" 1-3/8"
25,4(1") 28,58(1-1/8") 28,58(1-1/8") 28,58(1-1/8")
9,52(3/8") 9,52(3/8") 9,52(3/8") 9,52(3/8")
m 300 300 300 300
Kg 15,0 + 12,0 15,0 + 12,0 13,0 x 2 15,0 x 2
°C
% 50 - 130 50 - 130 50 - 130 50 - 130
N° 40 40 40 40
Kg 640 640 700 700
mm 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60)
Outdoor units matchings
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll
Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve
Refrigerant type
Liquid pipe diameter after 1° distributor kit mm(inch")
Gas pipe diameter after 1° distributor kit mm(inch")
Discharge pipe diameter after 1° distributor kit mm(inch")
Diameter of balancing pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
Outdoor units matchings
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll
Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve
Refrigerant type
Liquid pipe diameter after 1° distributor kit mm(inch")
Gas pipe diameter after 1° distributor kit mm(inch")
Discharge pipe diameter after 1° distributor kit mm(inch")
Diameter of balancing pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
VR
VR
FF
Outdoor units matchings - technical data
96 www.argoclima.com
CAPACITY CLASSES (HP) 34 HP 36 HP 38 HP 40 HP
AES 14+10+10 MI3H AES 16+10+10 MI3H AES 16+12+10 MI3H AES 14+14+10 MI3H
96,00 / 108,00 101,00 / 113,00 107,00 / 119,00 113,00 / 127,00
E.E.R. / C.O.P. 3,45 / 3,93 3,41 / 3,88 3,42 / 3,84 3,42 / 3,88
m³/h 12.000 + 9.600 x 2 13.200 + 9.600 x 2 13.200 +10.800 + 9.600 13.200 +12.000 + 9.600
61 / 58 61,5 / 58,5 61,5 / 58,5 62 / 59
73,5 74 74 75,5
400/3N/50 400/3N/50 400/3N/50 400/3N/50
27,8 / 27,5 29,1 / 28,7 31,3 / 31,0 33,0 / 32,7
A 45,1 / 44,6 48,0 / 47,2 51,0 / 50,0 54,0 / 54,0
R410A R410A R410A R410A
19,05(3/4") 19,05(3/4") 19,05(3/4") 19,05(3/4")
1-3/8" 1-5/8" 1-5/8" 1-5/8"
28,58(1-1/8") 28,58(1-1/8") 1-3/8" 1-3/8"
9,52(3/8") 9,52(3/8") 9,52(3/8") 9,52(3/8")
m 300 300 300 300
Kg 15,0+12,0 x 2 15,0+12,0 x 2 15,0+12,0 x 2 15,0 x 2+12,0
°C
% 50 - 130 50 - 130 50 - 130 50 - 130
N° 40 40 40 40
Kg 930 930 930 990
mm 1.887x2.870x890(+60) 1.887x2.870x890(+60) 1.887x2.870x890(+60) 1.887x2.870x890(+60)
CAPACITY CLASSES (HP) 42 HP 44 HP 46 HP 48 HP
AES 16+16+10 MI3H AES 16+16+12 MI3H AES 16+16+14 MI3H AES 16+16+16 MI3H
118,00 / 132,00 124,00 / 138,00 130,00 / 145,00 135,00 / 150,00
E.E.R. / C.O.P. 3,40 / 3,84 3,41 / 3,81 3,40 / 3,83 3,38 / 3,79
m³/h 13.200 x 2 + 9.600 13.200 x2 + 10.800 13.200 x 2 + 12.000 13.200 x 3
62,5 / 59,5 62,5 / 59,5 63 / 60 63 / 60
75,5 76 76,5 77
400/3N/50 400/3N/50 400/3N/50 400/3N/50
34,7 / 34,4 36,4 / 36,2 38,2 / 37,9 39,9 / 39,6
A 57,0 / 56,0 60,0 / 59,0 63,0 / 62, 0 65,0 / 65,0
R410A R410A R410A R410A
19,05(3/4") 19,05(3/4") 19,05(3/4") 19,05(3/4")
1-5/8" 1-5/8" 1-5/8" 1-5/8"
1-3/8" 1-3/8" 1-3/8" 1-3/8"
9,52(3/8") 9,52(3/8") 9,52(3/8") 9,52(3/8")
m 300 300 300 300
Kg 15,0 x 2+12,0 15,0 x 2+12,0 15,0 x 3 15,0 x 3
°C
% 50 - 130 50 - 130 50 - 130 50 - 130
N° 40 40 40 40
Kg 990 990 1050 1050
mm 1.887x2.870x890(+60) 1.887x2.870x890(+60) 1.887x2.870x890(+60) 1.887x2.870x890(+60)
Outdoor units matchings
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll
Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve
Refrigerant type
Liquid pipe diameter after 1° distributor kit mm(inch")
Gas pipe diameter after 1° distributor kit mm(inch")
Discharge pipe diameter after 1° distributor kit mm(inch")
Diameter of balancing pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Net weight Outdoor
Net dimension Outdoor (H./W./D.)
Outdoor units matchings
Units
Cooling/Heating capacity kW
(kW/kW)
Air flowrate (h.)
Sound pressure (normal/silent mode) dB(A)
Sound power (normal mode) dB(A)
Power supply V/Ph/Hz
Power input (cooling/heating) kW
Running current (cooling/heating)
Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll
Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve
Refrigerant type
Liquid pipe diameter after 1° distributor kit mm(inch")
Gas pipe diameter after 1° distributor kit mm(inch")
Discharge pipe diameter after 1° distributor kit mm(inch")
Diameter of balancing pipe mm(inch")
Max. pipe lenght
Gas standard charge
Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit
Connectable indoor units
Net weight Outdoor
Net dimension Outdoor (H./W./D.)V
RF
VR
F
Mini Multiset V.R.F. DC
98 www.argoclima.com
part A part B part C part D part E part F part G part H part I part JPosition
Gas pipe
Gas pipe
Gas pipe
Gas pipe
Gas pipe
Liquid pipe
Liquid pipe Liquid pipe
Liquid pipe
Liquid pipe
insulator
insulator
insulator
insulator
insulator
insulator
insulator
insulator
insulator
insulator
Dimension
VR
FV
RF
99www.argoclima.com
Solenoid valve controller
M3 EVVC (B)
Solenoid valve kits for 3 - way sy
M3 EVV 22-56B (for 22-56 models of indoor units)
It is possible to connect 1 only solenoid valve kit controlling a group of indoor units, with a total capacity up to 5,6 kW.
All the indoor units of the group will operate in the same mode (cooling or heating)
M3 EVV 73-140B (for 73-140 models of indoor units)
It is possible to connect 1 only solenoid valve kit controlling a group of indoor units, with a total capacity up to 14 kW.
All the indoor units of the group will operate in the same mode (cooling or heating)
In case 1 only solenoid valve kit is used to control a group of indoor units, only 1 control must be used for the whole group
VR
VR
FF
Distribution joint kits for 3 - way systems
100 www.argoclima.com
Position
Dimension
Part A
ø38.1
Part B
ø31.75
Part C
ø28.58
Part D
ø25.4
Part E
ø22.22
Part F
ø19.05
Part G
ø15.88
Part H
ø12.7
Part I
ø9.52
Part J
ø6.35
p p g ( )
M3DDV22
M3DDVE68
M3DDV135
Suction pipe Liquid pipeDischarge pipe
GH
HG
G
G
G
F H
HH
H II H
HIH
H
H
55
9212
145 55
40
777
186
136
69
235
Insulator Insulator Insulator
210
FFG FF
F
M3DDV68
M3DDVE135
Suction pipe Liquid pipeDischarge pipe
Insulator Insulator
Insulator
G F E E F GEF
G
H IHI
IH
A CB
A
B
B
BA
CD
ED F CC E F
F
DC
ED
C
D 130
340
G
G
G
50
B
B
B
B
C
615
375
180
31566
105 112
230
C
C
C
490300
126112
112
53
C
Suction pipe Liquid pipeDischarge pipe
Insulator InsulatorInsulator
I H IH
IH
GF E E F GEF
G
C
DE
CC DE F
F
C
D F G
G
EDC
FE
D
DE
50340
130
G
G
G
C
C
490300
C
112
126
D
D
DC
490300
12610183
230230
Suction pipeDischarge pipe
Liquid pipe
Insulator Insulator
G F E E F GEF
G
H IHI
IH
B
B B
EC DA FF AD CE
AC
DEF
HG
130
340
G
G
G
50B
BB
C
CC
F
90 105 11245
55
Suction pipe Liquid pipeDischarge pipe
Insulator Insulator Insulator
I H IH
IH
G F E E F GEF
GC
C
C
DE
DE F
F
D
D
DEF DEF EC
E
F
F
GHG
50340
130
G
G
G
300C
C
C
C
112
D
D
300
230230
126
16
F
55
74
112 126
16
F
55
LEGENDA :
letter in circle = female side
letter not in circle = male sideFF
VR
FV
RF
101www.argoclima.com
AWF 22 - 28 - 36 / AWS 56 - 73
AWF 22 - 28 - 36
AWS 56 - 73
High wall indoor unit for Mini Multiset and Multiset V.R.F. DC Inverter systems
New flat panel unit for 2,2 – 2,8 and 3,6 kW models: compact and elegant with its white pearl coloured panel, this new unit can be
easily integrated in every type of furniture
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room
Night set back capability
To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)
“I Feel” feature and temperature sensor indoor the remote control
Dry function
New three-speed tangential fan by remote control, granting a better and low noise air diffusion
Horizontal flap swinging or to be set to a fixed position by remote control
Vertical flap by manual control
Washable air filter
Three-way condensate discharge (right, central and left)
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
VR
VR
FF
Technical data
102 www.argoclima.com
PRODUCT NAME AWF22MH AWF28MH AWF36MH
2,20 2,50 2,80 3,20 3,60 4,20
BTU/h 7.500 8.520 9.550 10.920 12.280 14.320
1.890 2.150 2.410 2.750 3.100 3.610
540-450-360 540-450-360 600-510-390
l/h 1,3 1,6 2,0
n° 3 + Auto 3 + Auto 3 + Auto
35-32-28 35-32-28 37-33-29
46-43-39 46-43-39 48-44-40
230/1/50 230/1/50 230/1/50
0,037 0,038 0,037 0,038 0,043 0,044
R410A R410A R410A
6,35(1/4") 6,35(1/4") 6,35(1/4")
12,70(1/2") 12,70(1/2") 12,70(1/2")
Kg 10,0 10,0 10,0
mm 285x825x217 285x825x217 285x825x217
Features Units Cooling Heating Cooling Heating Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
PRODUCT NAME AWS56MH AWS73MH
5,60 6,30 7,30 8,00
BTU/h 19.100 21.480 24.890 27.280
4.820 5.420 6.280 6.880
720-600-480 960-840-600
l/h 2,3 4,0
n° 3 + Auto 3 + Auto
36-32-28 42-38-35
47-33-39 53-49-46
230/1/50 230/1/50
0,033 0,033 0,052 0,052
R410A R410A
6,35(1/4") 9,52(3/8")
12,70(1/2") 15,88(5/8")
Kg 14 21
mm 285x995x203 330x1.140x228
Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
VR
FV
RF
103www.argoclima.com
ASS 22-28-36-45-56
Four-way cassette indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room
Night set back capability
To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)
“I Feel” feature and temperature sensor indoor the remote control
Dry function
New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion
Horizontal flap swinging or to be set on a fixed position by remote control
Washable air filter
Integrated pump for condensate discharge
Special anti-dripping system on the four air outlets
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
VR
VR
FF
104 www.argoclima.com
Technical data
PRODUCT NAME ASS22MH ASS28MH
2,20 2,50 2,80 3,20
BTU/h 7.500 8.520 9.550 10.920
1.890 2.150 2.410 2.750
700-600-500 700-600-500
l/h 0,9 1,0
n° 3 + Auto 3 + Auto
43-40-37 43-40-37
52-49-46 52-49-46
230/1/50 230/1/50
0,087 0,087 0,087 0,087
R410A R410A
6,35(1/4") 6,35(1/4")
12,70(1/2") 12,70(1/2")
Kg 16/2,5 16/2,5
mm 296x575x575 296x575x575
mm 41x730x730 41x730x730
PRODUCT NAME ASS36MH ASS45MH
3,60 4,20 4,70 5,20
BTU/h 12.280 14.320 16.020 17.740
3.100 3.610 4.040 4.470
700-600-500 750-630-530
l/h 1,2 2,3
n° 3 + Auto 3 + Auto
43-40-37 44-40-37
52-49-46 53-49-46
230/1/50 230/1/50
0,087 0,087 0,087 0,087
R410A R410A
6,35(1/4") 6,35(1/4")
12,70(1/2") 12,70(1/2")
Kg 16/2,5 18/2,5
mm 296x575x575 296x575x575
mm 41x730x730 41x730x730
PRODUCT NAME ASS56MH
5,60 6,30
BTU/h 19.100 21.480
4.820 5.420
750-630-530
l/h 2,3
n° 3 + Auto
44-40-37
53-49-46
230/1/50
0,087 0,087
R410A
6,35(1/4")
12,70(1/2")
Kg 18/2,5
mm 296x575x575
mm 41x730x730
Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) at 2 m dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor / grille
Net dimension Indoor (H./W./D.)
Net dimension grille (H./W./D.)
Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) at 2 m dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor / grille
Net dimension Indoor (H./W./D.)
Net dimension grille (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) at 2 m dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor / grille
Net dimension Indoor (H./W./D.)
Net dimension grille (H./W./D.)
VR
FV
RF
105www.argoclima.com
ASS 73 - 106 - 140
Four-way cassette indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room
Night set back capability
To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)
“I Feel” feature and temperature sensor indoor the remote control
Dry function
New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion
Horizontal flap swinging or to be set on a fixed position by remote control
Special system to avoid condensate dripping from air outlet ribs
Washable air filter
Integrated pump for condensate discharge
Special anti-dripping system on the four air outlets
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
VR
VR
FF
106 www.argoclima.com
Technical data
ASS 73
ASS 73
ASS 106/140
ASS 106/140
A (mm) B (mm)566856
8201 110
261291
182182
157157
A (mm) B (mm) C (mm) D (mm) E (mm) Weight (kg)2835
124124
308338
PRODUCT NAME ASS73MH
7,30 8,00
BTU/h 24.890 27.280
6.280 6.880
1.140-1.020-840
l/h 3,6
n° 3 + Auto
47-45-41
56-54-50
230/1/50
0,175 0,120
R410A
9,52(3/8")
15,88(5/8")
Kg 22/6
mm 338x860x860
mm 30x860x860
PRODUCT NAME ASS106MH
10,60 11,40
BTU/h 36.150 38.880
9.120 9.800
1.920-1.680-1.320
l/h 4,6
n° 3 + Auto
53-50-46
62-59-55
230/1/50
0,210 0,150
R410A
9,52(3/8")
15,88(5/8")
Kg 27/8
mm 338x1.150x860
mm 30x1.150x860
PRODUCT NAME ASS140MH
14,00 16,00
BTU/h 47.740 54.560
12.040 13.760
1.920-1.680-1.320
l/h 6,3
n° 3 + Auto
53-50-46
62-59-55
230/1/50
0,210 0,150
R410A
9,52(3/8")
15,88(5/8")
Kg 27/8
mm 338x1.150x860
mm 30x1.150x860
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) at 2 m dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor / grille
Net dimension Indoor (H./W./D.)
Net dimension grille (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) at 2 m dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor / grille
Net dimension Indoor (H./W./D.)
Net dimension grille (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) at 2 m dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor / grille
Net dimension Indoor (H./W./D.)
Net dimension grille (H./W./D.)
VR
FV
RF
107www.argoclima.com
Ducted indoor unit with optional two-way discharge plenum, to be matched with Mini Multiset and Multiset V.R.F. DC Inverter
systems
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room
Night set back capability
To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)
“I Feel” feature and temperature sensor indoor the remote control
Dry function
Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm W.C.)
Washable air filter
Integrated pump for condensate discharge
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
ADS 22 - 28 - 36
VR
VR
FF
108 www.argoclima.com
Technical data
PRODUCT NAME ADS22MH
2,20 2,50
BTU/h 7.500 8.520
1.890 2.150
600-510-440
l/h 0,8
mm W.G. 5-7
n° 3 + Auto
54-52-49
45-43-40
230/1/50
0,110 0,110
R410A
6,35(1/4")
12,7(1/2")
mm 200
kg 30
mm 266x926x571
mm 266x926x771
PRODUCT NAME ADS28MH
2,80 3,20
BTU/h 9.550 10.920
2.410 2.750
600-510-440
l/h 0,8
mm W.G. 5-7
n° 3 + Auto
54-52-49
45-43-40
230/1/50
0,110 0,110
R410A
6,35(1/4")
12,7(1/2")
mm 200
kg 30
mm 266x926x571
mm 266x926x771
PRODUCT NAME ADS36MH
3,60 4,20
BTU/h 12.280 14.320
3.100 3.610
600-510-440
l/h 1,5
mm W.G. 5-7
n° 3 + Auto
54-52-49
45-43-40
230/1/50
0,110 0,110
R410A
6,35(1/4")
12,7(1/2")
mm 200
kg 30
mm 266x926x571
mm 266x926x771
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.-m.-l.) m3/hDehumidification
External static pressure (min-max)
Fan speeds
Sound power Indoor (h.m.l.) dB(A)
Sound pressure Indoor (h.-m.-l.) at plenum connection dB(A)
Sound pressure Indoor at ducts exit dB(A) < 20
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Duct diameter of the 2-way discharge plenum (optional)
Net weight Indoor
Net dimension Indoor (H./W./D.)
Net dimension Indoor with plenum (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.-m.-l.) m3/hDehumidification
External static pressure (min-max)
Fan speeds
Sound power Indoor (h.m.l.) dB(A)
Sound pressure Indoor (h.-m.-l.) at plenum connection dB(A)
Sound pressure Indoor at ducts exit dB(A) < 20
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Duct diameter of the 2-way discharge plenum (optional)
Net weight Indoor
Net dimension Indoor (H./W./D.)
Net dimension Indoor with plenum (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.-m.-l.) m3/hDehumidification
External static pressure (min-max)
Fan speeds
Sound power Indoor (h.m.l.) dB(A)
Sound pressure Indoor (h.-m.-l.) at plenum connection dB(A)
Sound pressure Indoor at ducts exit dB(A) < 20
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Duct diameter of the 2-way discharge plenum (optional)
Net weight Indoor
Net dimension Indoor (H./W./D.)
Net dimension Indoor with plenum (H./W./D.)VR
FV
RF
109www.argoclima.com
Ducted indoor unit with optional three-way discharge plenum, to be matched with Mini Multiset and Multiset V.R.F. DC Inverter
systems
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room
Night set back capability
To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)
“I Feel” feature and temperature sensor indoor the remote control
Dry function
Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm W.C.)
Washable air filter
Integrated pump for condensate discharge
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
ADS 45 - 56 - 64
VR
VR
FF
110 www.argoclima.com
Technical data
PRODUCT NAME AD45MHG
4,70 5,20
BTU/h 16.020 17.740
4.040 4.470
875-600-400
l/h 2,3
mm W.G. 5-7
n° 3 + Auto
54-47-42
45-38-33
230/1/50
0,138 0,138
R410A
6,35(1/4")
12,7(1/2")
mm 200
kg 35
mm 266x1.132x571
mm 266x1.132x771
PRODUCT NAME ADS56MH
5,60 6,30
BTU/h 19.100 21.480
4.820 5.420
875-600-400
l/h 2,3
mm W.G. 5-7
n° 3 + Auto
54-47-42
45-38-33
230/1/50
0,138 0,138
R410A
6,35(1/4")
12,7(1/2")
mm 200
kg 35
mm 266x1.132x571
mm 266x1.132x771
PRODUCT NAME AD64MHG
6,40 7,00
BTU/h 21.850 23.870
5.500 6.020
1000-700-600
l/h 2,6
mm W.G. 5-7
n° 3 + Auto
57-49-46
48-40-37
230/1/50
0,136 0,136
R410A
9,52(3/8")
15,88(5/8")
mm 200
kg 35
mm 266x1.132x571
mm 266x1.132x771
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
External static pressure (min-max)
Fan speeds
Sound power Indoor (h.m.l.) dB(A)
Sound pressure Indoor (h.m.l.) at discharge plenum connection dB(A)
Sound pressure Indoor at ducts exit dB(A) < 20
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Duct diameter of the 3-way discharge plenum (optional)
Net weight Indoor
Net dimension Indoor (H./W./D.)
Net dimension Indoor with plenum (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.-m.-l.) m3/hDehumidification
External static pressure (min-max)
Fan speeds
Sound power Indoor (h.-m.-l.) dB(A)
Sound pressure Indoor (h.-m.-l.) at plenum connection dB(A)
Sound pressure Indoor at ducts exit dB(A) < 20
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Duct diameter of the 3-way discharge plenum (optional)
Net weight Indoor
Net dimension Indoor (H./W./D.)
Net dimension Indoor with plenum (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.-m.-l.) m3/hDehumidification
External static pressure (min-max)
Fan speeds
Sound power Indoor (h.m.l.) dB(A)
Sound pressure Indoor (h.-m.-l.) at plenum connection dB(A)
Sound pressure Indoor at ducts exit dB(A) < 20
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Duct diameter of the 3-way discharge plenum (optional)
Net weight Indoor
Net dimension Indoor (H./W./D.)
Net dimension Indoor with plenum (H./W./D.)VR
FV
RF
111www.argoclima.com
Three/Four way Ducted indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room
Night set back capability
To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)
“I Feel” feature and temperature sensor indoor the remote control
Dry function
Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 10 mm W.C.)
Integrated pump for condensate discharge
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
ADS 106 - 140
ADS 73
ADS 73 - 106 - 140
VR
VR
FF
112 www.argoclima.com
Technical data
PRODUCT NAME ADS73MH
7,3 8,0
BTU/h 24.890 27.280
6.280 6.880
1.080-900-780
l/h 3,5
mm W.G. 5,1-9,4
n° 3 + Auto
43-39-36
34-30-27
230/1/50
0,195 0,183
R410A
9,52(3/8")
15,88(5/8")
mm 200
kg 32
mm 310x1.000x630
PRODUCT NAME ADS106MH
10,6 11,4
BTU/h 36.140 38.880
9.120 9.800
1.800-1.560-1.260
l/h 4,2
mm W.G. 8,1-12,4
n° 3 + Auto
47-42-40
38-33-31
230/1/50
0,327 0,315
R410A
9,52(3/8")
15,88(5/8")
mm 200
Kg 47
mm 310x1.480x630
PRODUCT NAME ADS140MH
14,00 16,00
BTU/h 47.740 54.560
12.040 13.760
1.980-1.560-1.320
l/h 6,6
mm W.G. 8-11,5
n° 3 + Auto
49-46-42
40-37-33
230/1/50
0,325 0,313
R410A
9,52(3/8")
15,88(5/8")
mm 200
Kg 47
mm 310x1.480x630
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
External static pressure (min-max)
Fan speeds
Sound power Indoor (h.m.l.) dB(A)
Sound pressure Indoor (h.m.l.) dB(A)
Sound pressure Indoor at ducts exit dB(A) < 20
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Ducts diameter
Net weight Indoor
Net dimension Indoor (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
External static pressure (min-max)
Fan speeds
Sound power Indoor (h.m.l.) dB(A)
Sound pressure Indoor (h.m.l.) dB(A)
Sound pressure Indoor at ducts exit dB(A) < 20
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Ducts diameter
Net weight Indoor
Net dimension Indoor (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
External static pressure (min-max)
Fan speeds
Sound power Indoor (h.m.l.) dB(A)
Sound pressure Indoor (h.m.l.) dB(A)
Sound pressure Indoor at ducts exit dB(A) < 20
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Ducts diameter
Net weight Indoor
Net dimension Indoor (H./W./D.)VR
FV
RF
113www.argoclima.com
Underceiling indoor unit for Mini Multiset and Multiset V.R.F. DC Inverter systems
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room
Night set back capability
To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)
“I Feel” feature and temperature sensor indoor the remote control
Dry function
New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion
Horizontal flap swinging or to be set on a fixed position by remote control
Vertical flap by manual control
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
ACS 73 - 106 - 140
VR
VR
FF
114 www.argoclima.com
Technical data
PRODUCT NAME ACS73MH
7,3 8,0
BTU/h 24.890 27.280
6.280 6.880
1.098-900-840
l/h 3,0
n° 3 + Auto
38-36-33
49-47-44
230/1/50
0,043 0,042
R410A
9,52(3/8")
15,88(5/8")
Kg 25,0
mm 210x1.180x680
PRODUCT NAME ACS106MH
10,6 11,4
BTU/h 36.140 38.880
9.120 9.800
1.650-1.380-1.200
l/h 3,9
n° 3 + Auto
41-38-35
52-49-46
230/1/50
0,074 0,073
R410A
9,52(3/8")
15,88(5/8")
Kg 33
mm 210x1.595x680
PRODUCT NAME ACS140MH
14,00 16,00
BTU/h 47.740 54.560
12.040 13.760
1.800-1.560-1.320
l/h 5,6
n° 3 + Auto
43-40-37
54-51-48
230/1/50
0,086 0,085
R410A
9,52(3/8")
15,88(5/8")
Kg 33,0
mm 210x1.595x680
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
Features Units Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.m.l.) dB(A)
Sound power Indoor (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
VR
FV
RF
115www.argoclima.com
Floor/ceiling indoor unit for Mini Multiset and Multiset V.R.F. DC Inverter systems
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room
Night set back capability
To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)
“I Feel” feature and temperature sensor indoor the remote control
Dry function
New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion
Horizontal flap swinging or to be set on a fixed position by remote control
Vertical flap by manual control
Washable air filter
Optional active carbon filters
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
FC 22 - 28 - 36 - 45 - 56 - 64
VR
VR
FF
116 www.argoclima.com
Technical data
PRODUCT NAME FC22MHG FC28MHG
2,20 2,50 2,80 3,20
BTU/h 7.500 8.520 9.550 10.920
1.890 2.150 2.410 2.750
700-590-500 700-590-500
l/h 1,0 1,2
n° 3 + Auto 3 + Auto
47-43-38 47-43-38
55-51-46 55-51-46
230/1/50 230/1/50
0,065 0,065 0,065 0,065
R410A R410A
6,35(1/4") 6,35(1/4")
12,70(1/2") 12,70(1/2")
Kg 23,5 23,5
mm 680x900x190 680x900x190
PRODUCT NAME FC36MHG FC45MHG
3,60 4,20 4,70 5,20
BTU/h 12.280 14.320 16.020 17.740
3.100 3.610 4.040 4.470
700-590-500 830-760-665
l/h 1,3 2,3
n° 3 + Auto 3 + Auto
47-43-38 52-49-46
55-51-46 60-57-54
230/1/50 230/1/50
0,065 0,065 0,088 0,088
R410A R410A
6,35(1/4") 6,35(1/4")
12,70(1/2") 12,70(1/2")
Kg 23,5 23,5
mm 680x900x190 680x900x190
PRODUCT NAME FC56MHG FC64MHG
5,60 6,30 6,40 7,00
BTU/h 19.100 21.480 21.850 23.870
4.820 5.420 5.500 6.020
830-760-665 830-760-665
l/h 2,3 2,3
n° 3 + Auto 3 + Auto
52-49-46 52-49-46
60-57-54 60-57-54
230/1/50 230/1/50
0,088 0,088 0,088 0,088
R410A R410A
6,35(1/4") 9,52(3/8")
12,70(1/2") 15,88(5/8")
Kg 23,5 23,5
mm 680x900x190 680x900x190
Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.-m.-l.) at 2m dB(A)
Sound power Indoor (h.-m.-l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.-m.-l.) at 2m dB(A)
Sound power Indoor (h.-m.-l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.-m.-l.) at 2m dB(A)
Sound power Indoor (h.-m.-l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
VR
FV
RF
117www.argoclima.com
Slim ducted indoor unit, available for floor or wall or ceiling installation, to be matched with Mini Multiset and Multiset V.R.F. DC Inverter
systems
Especially projected for hotel applications
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room
Night set back capability
To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)
“I Feel” feature and temperature sensor indoor the remote control
Dry function
New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion
Washable air filter
Optional active carbon filters
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
SD 22 - 28 - 36 - 45 - 56 - 64
VR
VR
FF
118 www.argoclima.com
Technical data
PRODUCT NAME SD22MHG SD28MHG
2,20 2,50 2,80 3,20
BTU/h 7.500 8.520 9.550 10.920
1.890 2.150 2.410 2.750
470-380-340 470-380-340
l/h 1,0 1,2
n° 3 + Auto 3 + Auto
37-30-26 37-30-26
45-38-34 45-38-34
230/1/50 230/1/50
0,037 0,037 0,037 0,037
R410A R410A
6,35(1/4") 6,35(1/4")
12,70(1/2") 12,70(1/2")
Kg 25 25
mm 585x890x190 585x890x190
PRODUCT NAME SD36MHG SD45MHG
3,60 4,20 4,70 5,20
BTU/h 12.280 14.320 16.020 17.740
3.100 3.610 4.040 4.470
470-380-340 620-540-450
l/h 1,3 2,3
n° 3 + Auto 3 + Auto
37-30-26 45-41-33
45-38-34 53-49-41
230/1/50 230/1/50
0,037 0,037 0,065 0,065
R410A R410A
6,35(1/4") 6,35(1/4")
12,70(1/2") 12,70(1/2")
Kg 25 25
mm 585x890x190 585x890x190
PRODUCT NAME SD56MHG SD64MHG
5,60 6,30 6,40 7,00
BTU/h 19.100 21.480 21.850 23.870
4.820 5.420 5.500 6.020
620-540-450 680-600-520
l/h 2,3 3,3
n° 3 + Auto 3 + Auto
45-41-33 49-45-40
53-49-41 57-53-48
230/1/50 230/1/50
0,065 0,065 0,088 0,088
R410A R410A
6,35(1/4") 9,52(3/8")
12,70(1/2") 15,88(5/8")
Kg 25 25
mm 585x890x190 585x890x190
Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.-m.-l.) at 2m dB(A)
Sound power Indoor (h.-m.-l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.-m.-l.) at 2m dB(A)
Sound power Indoor (h.-m.-l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
Features Units Cooling Heating Cooling Heating
Cooling/Heating capacity
kW
kcal/h
Air flowrate Indoor (h.m.l.) m3/hDehumidification
Fan speeds
Sound pressure Indoor (h.-m.-l.) at 2m dB(A)
Sound power Indoor (h.-m.-l.) dB(A)
Power supply V/Ph/Hz
Running consumption kW
Refrigerant type
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight Indoor
Net dimension Indoor (H./W./D.)
VR
FV
RF
119www.argoclima.com
Ducted indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems
High static pressure, low noise
Easy placement in any type of environment
Automatic change-over between cooling and heating modes
Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room
Night set back capability
To be managed by wired and wireless controllers of Multiset V.R.F. DC Inverter systems (all optional)
“I Feel” feature and temperature sensor indoor the remote control
Dry function
Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful
microprocessor
Valve Kit to prevent gas accumulation: with the exception of mono systems, it takes 2 valves each unit of models 224 and 280 if
connected to the same outdoor unit in a multi-system
ADPS 140 ADPS 224 - 280
ADPS 140 - 224 - 280
VR
VR
FF
120 www.argoclima.com
Technical data
PRODUCT NAME ADPS140MH
14,0 16,02160/2100/1980
167n° 3 + Auto
47/46/4458/57/55230/1/50
0,60/0,66/0,71 0,60/0,66/0,71A 2,80/2,90/3,00 2,80/2,90/3,00
9,52(3/8")15,88(5/8")
Kg 54mm 450/1065/620
Features Units Cooling HeatingCooling/Heating capacity kWAir flowrate (h.m.l.) mExternal static pressure (max) PaFan speeds Sound power (h.m.l.) dB(A)Sound pressure (h.m.l.) dB(A)Power supply V/Ph/HzRunning consumption (min.-med.-max.) kWRunning current (min.-med.-max.)Liquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Net weightNet dimensions (H./W./D.)
PRODUCT NAME ADPS224MH
22,4 25
3360/3190/2980
176
n° 3 + Auto
48/47/46
59/58/57
230/1/50
0,87/0,90/0,93 0,87/0,90/0,93
A 4,50/4,06/4,07 4,05/4,06/4,07
9,52(3/8")
19,05(3/4")
Kg 110
mm 467/1428/1230
Features Units Cooling Heating
Cooling/Heating capacity kW
Air flowrate (h.m.l.) m
External static pressure (max) Pa
Fan speeds
Sound power (h.m.l.) dB(A)
Sound pressure (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption (min.-med.-max.) kW
Running current (min.-med.-max.)
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight
Net dimensions (H./W./D.)
PRODUCT NAME ADPS280MH
28,0 31,50
4320/4200/3960
216
n° 3 + Auto
51/50/49
62/61/60
230/1/50
1,27/1,33/1,39 1,27/1,33/1,39
A 6,04/6,06/6,07 6,04/6,06/6,07
9,52(3/8")
22,22 (7/8")
Kg 120
mm 467/1428/1230
Features Units Cooling Heating
Cooling/Heating capacity kW
Air flowrate (h.m.l.) m
External static pressure (max) Pa
Fan speeds
Sound power (h.m.l.) dB(A)
Sound pressure (h.m.l.) dB(A)
Power supply V/Ph/Hz
Running consumption (min.-med.-max.) kW
Running current (min.-med.-max.)
Liquid pipe diameter mm(inch")
Gas pipe diameter mm(inch")
Net weight
Net dimensions (H./W./D.)
VR
FV
RF
121www.argoclima.com
Controlli controls and accessories
Schedule timer able to manage up to 64
indoor units with customized programming of
all features, on/off cycles, etc.
System controller to be used to manage only
on/off cycles for a system up to 16 groups /
64 indoor units, to be used in matching with
other controllers (remote controllers, system
controllers, etc.)
System controller to be used to manage and
program a system up to 16 groups / 64 indoor
units, with or without remote controllers; it can
be matched with schedule timer and intelli-
gent controller
Interface PLC for outdoor units: can control
up to 4 outdoor units. Required for “Demand”
control, typical of 3-way systems
New standard wired remote controller
equipped with weekly timer,caracterized by full
features control, selfdiagnostic and centralized
programming capabilities.
New Touch Screen Intelligent Controller for
WEB: to be used to manage and program
a system up to 256 indoor units, organized
in 4 groups of 64 units each, also without
wired controllers; it can be matched with
the schedule timer and in case of three/four-
group installations it must be connected with
the communication adapter on the outdoor
unit. User friendly touch screen operation.
Web browser: it allows to control VRF system
by its own PC at home using an Internet
connection with a LAN cable.
Infrared remote controller to be used with
high-wall indoor units
Infrared remote controller to be used with
cassette and floor/ceiling indoor units
Infrared remote controller to be used with
underceiling indoor units
Infrared remote controller to be used, in
matching with a special infrared receiver,
with the full range of indoor units; it shows
the operation status of the air-conditioner
Standard wired remote controller with full
features control, self-diagnostic and
centralized programming capabilities
Simplified wired remote controller to be
used with the full range of indoor units; it
controls all the main features
Remote sensor to be used with the full
range of indoor units to detect the room
temperature when no remote controller
sensor or body sensor is used: suggested
for air-conditioner systems without remote
controller
VR
VR
FF
122 www.argoclima.com
Multiset v.r.f. controls functions
TIMER
Picture
Description Standard wiredControl
Standard wiredControl + Timer
Simplified wiredControl
Infrared remoteControl
WeeklyTimer
REM HW standard REM HW TM REM HWS REM HL REM HW T
-
17 / 27 °C 17 / 27 °C 17 / 27 °C 17 / 27 °C-
16 / 26 °C 16 / 26 °C 16 / 26 °C 16 / 26 °C-
18 / 30 °C 18 / 30 °C 18 / 30 °C 18 / 30 °C-
18 / 30 °C 18 / 30 °C 18 / 30 °C 18 / 30 °C-
3 + auto 3 + auto 3 + auto 3 + auto-
temperaure +/- temperature +/- temperature +/- temperature +/--
flap flap flap flap-
timer 72 weekly timer-
timer 72 h weekly timer
sensor t.(2) sensor t.(2) sensor t.(2) sensor t.(2)
Interdiction to use indoor unit
control functions
Fault alarm Fault alarm Fault alarm--
Dirty filter Dirty filter Dirty filter--
N° of units controlled max. 8 max. 8 max. 8 max. 8
1 group with 64 units 8 groups with 8 units
4 groups with 16 units
It works only with a secondary control
It works only with a secondary control
It works only with a secondary control
It works only with a secondary control
6 daily programs x 7 days + holiday
You can select 6 different addresses
Power supplyby REM HW-64 S
or T10-PCBindoor unit connector
Oth
erFu
nctio
ns
INDIVIDUALS CONTROLS
Model
VR
FV
RF
123www.argoclima.com
Multiset v.r.f. controls functions
Picture
Description System control ON/OFFSystem control
Intelligent touch controller
Adapter for control system
LonWorksInterface
PLCInterface
REM HW 64S REM HW 16S REM HW 256S REM HWAS LWI IEM
-
17 / 27 °C-
17 / 27 °C-
17 / 27 °C 17 / 27 °C
16 / 26 °C-
16 / 26 °C-
16 / 26 °C 16 / 26 °C
18 / 30 °C-
18 / 30 °C-
18 / 30 °C 18 / 30 °C
18 / 30 °C-
18 / 30 °C-
18 / 30 °C 18 / 30 °C
3 + auto-
3 + auto-
3 + auto 3 + auto
temperature +/--
temperature +/--
temperature +/- temperature +/-
flap-
flap-
palfpalf
--timer
---
Interdiction to use indoor unit control
functions
Interdiction to use indoor unit control
functions- ---
Malfunctions report-
Fault alarm Fault alarm- -
Dirty filter-----
N° of units controlled
16 groups of 4 units(max 64 units)
16 groups of 4 units(max 64 units)
64 units x 4 systemsmax 256 indoor units30 units x 4 systems
max 120 outdoor units
2 systems, 64 units x 2 max 128 units
16 groups of 4 units(max 64 units)
16 groups of 4 units(max 64 units)
Over 3 systemsyou must use
REMHWAS (max 7)
to use withREMHW256S(+3 systems)
You must use the individual controls
Monitoring and calculation of
consumption distribution
GROUP CONTROLS
The control central canperform functions of remote control and
system control, Intelligent Controller
Oth
erFu
nctio
ns
Model
VR
VR
FF
124 www.argoclima.com
REC 03/06/10/14/19/25/30/40
REC heat recovery units, characterized by small size and easy to install, are suitable for residential and commercial applications
Regulations require forced ventilation in realizing air conditioning and air treatment systems, with expulsion of air treated
and consequent increase in energy consumption and costs.
In all these cases REC heat recovery units allow over 50% of energy saving and ensure an adequate environmental comfort
through the use of a static heat exchanger made of aluminium.
REC heat recovery units are available in 8 sizes with airflows from 300 to 4000 m3 /h and high static pressure.
They work both in the summer and in winter.
Particularly suitable for false ceiling installation, they may be appropriately ducted allowing air supply and air suction directly
in the room.
High efficiency aluminium plated heat recovery, with airflows separated by special seals.
The side panels are fully removable, made of double-layer plate with thermal and sound insulation in polyethylene / polyester
with an average thickness of 10 mm for models REC 03-06-10 and 20mm for the other models.
In the lower part of the recovery unit is installed a condensate tank in stainless steel, with drain downward.
The fan group consists of 2 centrifugal fans with double inlet (for the REC 03 model single inlet) separated, one for the recovery
fresh air, the other for the exhaust air.
Single-phase electric motors (3-phase only for REC 40), 2 or 3 speeds.
The fans are mounted on anti-vibration easy removable support, which ensures a very low noise even at maximum speed.
They are also equipped with air filters with performance class G3, easily removable from each side of the unit and regenerate.
REC heat recovery units are available also in vertical version.
MAIN ACCESSORIES
VR
FV
RF
125www.argoclima.com
MODELLOMODEL 03 06 10 14 19 25 30 40
A mm 990 990 1150 1350 1450 1700 1700 1700 B mm 750 750 860 900 900 1230 1230 1230C mm 270 270 385 410 470 490 530 630D mm - - 230 230 280 305 305 405L mm 162 162 240 240 240 306 339 339 H mm 100 100 218 270 270 270 297 297 L1 mm 275 275 330 337 337 502 502 502H1 mm 153 153 267 267 327 347 387 487E mm 195 195 245 241 241 323 308 308 E1 mm 195 195 205 241 241 323 345 345F mm 170 170 238 224 284 290 331 377 G mm 197 197 225 241 241 323 323 323
½” ½” ½” ½” ½“ ½“ ½“ ½“kg 39 41 68 91 99 140 155 179
TYPE AOUTSIDE INSIDE
Fresh air
Exhaust air Supply air
Return air A90 R90
E90 M90
VR
VR
FF
126 www.argoclima.com
MODELS REC 03 REC 06 REC 10 REC 14
Max 300 500 1000 1400200 300 900 1250100 150 800 850
Max 100 100 90 145160 129 70 133167 127 47 113
Max 51,1 51,1 52,2 62,3
49,7 47,4 48,8 56,9
44,3 41,0 45,3 45,6Max
%52,0 56,1 53,4 52,157,0 62,5 54,8 53,566,4 71,1 56,3 58,4
Max 1,4 2,6 4,9 6,71,0 1,7 4,5 6,10,6 1,0 4,1 4,5
Max
°C
8,0 9,0 8,4 8,0
9,3 10,6 8,7 8,4
11,6 12,8 9,1 9,6
FAN
W 2x60 2x60 2x147 2x350
A 1,2 1,4 3 5,8
n° 3 3 3 3
n° 2 2 4 4
IP 20
B
230/1/50
DIMENSIONS / WEIGHT - REC
mm 990/750/270 990/750/270 1150/860/385 1350/900/410
Kg 39 41 68 91
Airflow rate m3/hMedMin
External static pressure PaMedMin
1 m sound pressure level dB (A)Med
Min
Recovery efficiency(1) MedMin
Saved power(1) kWMedMin
Supply temperature(1) Med
Min
Shaft power
Maximum current
Fan speeds
Poles
Protection degree - minimum
Temperature class - minimum
Power supply V/ph/Hz
Width/Length/Height
Net weight
(1) At the following conditions: room air temperature 20°C DB 50% R.H.; fresh air temperature -5°C.
MODELS REC 19 REC 25 REC 30 REC 40
Max 1900 2500 3200 40001570 1830 2500 -1340 1100 1800 3000
Max 120 110 170 170121 112 159 -119 112 144 147
Max 58,4 56,0 58,8 62,1
53,7 51,0 53,5 -
42,1 44,6 51,1 54,9Max
%51,8 57,6 56,0 55,754,1 61,5 59,0 -56,1 67,7 63,1 59,2
Max 9,0 13,2 16,4 20,37,8 10,3 13,5 -6,9 8,6 10,4 16,2
Max
°C
7,9 9,4 9,0 8,9
8,5 10,4 9,8 -
9,0 11,9 10,8 9,8
FAN
W 2x350 2x350 2x550 2x750
A 6,2 6 11,4 6,2
n° 3 3 3 2
n° 4 4 4 4
IP 20
B
230/1/50 400/3/50
DIMENSIONS / WEIGHT - REC
mm 1450/900/470 1700/1230/490 1700/1230/530 1700/1230/630
Kg 99 140 155 179
Airflow rate m3/hMedMin
External static pressure PaMedMin
1 m sound pressure level dB (A)Med
Min
Recovery efficiency(1) MedMin
Saved power(1) kWMedMin
Supply temperature(1) Med
Min
Shaft power
Maximum current
Fan speeds
Poles
Protection degree - minimum
Temperature class - minimum
Power supply V/ph/Hz
Width/Length/Height
Net weight
(1) At the following conditions: room air temperature 20°C DB 50% R.H.; fresh air temperature -5°C.
VR
FV
RF
131
Regulations on energy efficiency labelling
Argo air conditioners are compliant with the most recent European Standards for the reduction of energy consumption and atmospheric
pollution. The labels that indicate the energy efficiency class were introduced with European Community directive 2002/31/EC, which
makes reference to standard EN14511, which in turn provides precise reference tables for the energy efficiency class classification. Energy
efficiency labels are applied to products (air conditioners with a cooling power of up to 12 kW) on display at retail outlets. They are provided
to inform customers of the efficiency of the product they intend to purchase. The label is divided into two parts, a generic coloured label
and an adhesive black and white label that must be applied over the coloured one.
Our company provides both the labels mentioned above. The generic label is supplied directly at retail outlets, whilst the specific one is
placed inside the packaging of each air conditioner sold. In the event that the specific label has been lost, each retail outlet should be able
to provide another immediately by downloading it from the Internet or requesting it from our marketing dept.
The energy efficiency label indicates the energy class; class A is the highest and is awarded based on tables that compare thermal efficiency
and energy consumption. The indicators of the above ratio are known as: E.E.R. = Energy Efficiency Ratio: this is the ratio between cooling
power (in kw) and power consumption in cooling mode (in kw). C.O.P. = coefficient of performance: this is the ratio between heating power
(in kw) and power consumption in heating mode (in kw).
1) generic - coloured 2) specific - black/white
Example of an energy efficiency label:
The manufacturing company doesn’t assume any responsibility for mistakes
or omissions contained in this catalogue and reserves the right to make at
any time, even without notice, any change considered suitable for technical
or commercial purposes to its products.
headquarter
Via Varese, 90
21013 Gallarate (VA) ITALY
Tel: + 39 0331 755111
Fax: + 39 0331 776240
www.argoclima.com
www.a rgoc l ima .com
Argo is a brand of , European leader in Air Conditioning, Heating and Air Treatment.
7020
1220
1 - 0
3/20
12or
ango
tow
n.co
m