Argo Air Conditioner 2012

132
General Catalogue AIR CONDITIONING 2012

description

Argo Air Conditioner 2012

Transcript of Argo Air Conditioner 2012

General Catalogue

AIR CONDITIONING2012

www.argoclima.com

The company, our products and

our reference markets

Argoclima S.p.A. specialises in the supply of products and services for the air conditioning, heating and air treatment market. Our range of products are almost all designed and manufactured in the Argoclima factories (in Italy and France), they provide state-of-the-art solutions that stand out for their advanced technology, design and modular nature. These features allow all manner of problems to be quickly resolved and offer excellent solutions with top energy efficiency performance.In addition to the products normally on offer through retail channels (portable and wall-mounted air conditioning systems, dehumidifiers and supplementary heating), our company also offers a range of ARGO brand products. These include direct expansion air-conditioning systems ranging from 2.2 to 150 kW with COP levels of above 5.Segmentation by heat output allows for the quick and easy identification, differentiation and positioning of the range of products, which focus on applications ranging from private homes to office buildings and from small and medium-sized retail outlets to shopping centres... The direct expansion systems all make use of Full DC Inverter technology to create systems with many dozens of indoor units, with over 300 metres of piping and height differences between units of over 50 metres.

Condensing units and terminal units, designed using the most advanced design and manufacturing techniques, they work brilliantly within a wide range of outdoor temperatures from -20°C to +43°C. Their mechanical properties facilitate handling and installation, thus reducing the cost of building systems. They can also be controlled using the most advanced building control systems (CIB/BMS), via local, centralised and/or remote controllers with web and fieldbus interfaces (lonworks...).

Organisation

and services

Argoclima S.p.A. is specifically organised to best support the needs of various types of customers: the needs of Retail customers, for example, are sometimes similar and sometimes very different to those of Installation Technicians, Wholesalers and B2B operators. Private consumers can also find answers to their questions both via conventional means and services as well as via new computer technologies: our website, www.argoclima.com, provides a large amount of information at different levels of expertise and access in order to satisfy any type of request. An extensive network of After-Sales Service Centres and the European Spare-Parts Centre guarantee a high level of After-Sales Service. The After-Sales Service Centres are linked-up via Internet to specific web applications used to manage the various phases of scheduled or corrective maintenance operations. In order to meet the particular needs of installers who specialise in the sale of centralised systems, Argoclima S.p.A. offers a full-range of services through a well-structured organisation which reports to the Systems Division:

designer;

specific context/system design as a whole;

adapting to new technologies.

In order to provide the above-mentioned services, Argoclima S.p.A. has a team of qualified technicians and sales personnel, who receive regular training on technological and regulatory matters.Argoclima S.p.A.’s logistics centre is located near the town of Brescia and manages the entire logistics process for incoming and outgoing goods for customers throughout Europe and beyond.Argoclima S.p.A. has been in the marketplace for 80 years, a level of experience that provides absolute assurance of the company’s capacity for Innovation, Quality and Service in the manufacture of the finest Italian-made products.

www.argoclima.com

page 04

page 55

page 43

page 83

page 67

page 51

ON

OF

FFFFO

NO

FFF

iSERIESTM, a multi-functional integrated system

iSERIESTM is the commercial name for the HVAC system (heating, ventilation and air conditioner) manufactured by Argoclima S.p.A.; it comprises of a series of components that allow the creation of mono and multi-split systems, in air/air, air/water and mixed air/air plus air/water configurations, with or without the generation of domestic hot water and combination with thermal and photovoltaic solar systems.

4 www.argoclima.com

A complete system, not just a simple split unit…

is a system based entirely onrenewable energy sources, designed to provide heat even in Nordic areas in installations operating in outside temperatures as low as 30 degrees below zero, and to provide cool air in desert regions in installations operating at over 50 degrees, multifunctional and highly energy efficient.

offers truly integrated applications for comfort, scalability, expandability and modularity;multi-processor electronics control the 180 SVPWM DC Inverter, which modulates the heat energy according to real needs, from a minimum of 10% up to a maximum of 130% of nominal output.

is conceived, designed and built entirely in Italy, in the Argoclima laboratories and main factory in Gallarate in the province of Varese, 40 Km north of Milan and only 5 Km from the international airport of Milan Malpensa.

I SE

RIE

SI

SE

RIE

S

5www.argoclima.com

is a split system with a feature that has never been seen before: the same outdoor units are both mono and multi, they do not change based on the application and are compatible with all the indoor units in the iSERIESTM range. From 2012 six outdoor units will be available to satisfy the needs of the most demanding customers, covering a modulated heat output range from 0.6 kW to over 13 kW; the range will be further extended up to over 22 kW.

AEI1G30 AEI1G40 AEI1G50 AEI1G65 AEI1G80 AEI1G110*

Outdoor units

HEATINGCOOLING

*available in 2012

I S

ERRR

IS

ERRRR

IES

IES

Indoor units

6 www.argoclima.com

The indoor units in the iSERIESTM range are divided into categories by heat output and by application.

There are four heat output categories:- size A for heat output up to 4 kW

- size B for heat output up to 7 kW

- size C for heat output up to 11 kW

- size D for heat output up to 14 kW

Thanks to the iSERIESTM sophisticated inverter regulation system, the classic references of rated power outputs are replaced by a greater flexibility and the number of product codes and references is reduced by 70%.

WALL FLOORCEILING

FLOOR SLIMDUCTED

CASSETTE DUCTED HYDROKIT

The application categories are:

Air/Air type:

Air/Water type:

wall mounted two-way floor mounted floor mounted - reversible for ceiling mounting

Hydrokit for floor-mounted systems, radiators and fan coils

floor mounted - reversible for recessed ceiling mounting (slim ducted) cassette for false ceilings mono and multi-zone ductable

Domestic hot water

R410A

H2O

All indoor units can be connected individually or used in combination with other units, based on thermal balance criteria aimed at creating an integrated system that fully satisfies the requirements of the end customer.

MIXED AIR/AIR + AIR/WATER APPLICATIONI S

ER

IES

IS

ER

IES

Applications

is a primary and integrated system for heating, air conditioning, air treatment and domestic hot water production, entirely based on a sophisticated technique employing high efficiency inverter heat pumps, a renewable energy source that can be combined with thermal and photovoltaic solar power.

The flexibility of the iSERIESTM system satisfies the requirements of the residential market and small service sector applications: from the most simple high quality split unit systems to multi-zone systems with floor-mounted systems, to multi-split systems for apartments, offices and public spaces...

7www.argoclima.com

Great flexibility in the combination of different types and categories of indoor units allows many different applications to be realised that before required the use of different systems that were difficult to integrate with one another.

Below is a summary of possible applications that should give installation technicians an idea of the wide range of possibilities offered by the iSERIESTM system:

Air/air mono-split, from a typical high quality residential split unit system to solutions for small service sector applications, offices, restaurants, bars... also multi-zone systems with ductable units... or for special applications such as containers, motor homes...

Air/water mono-split, this solution is commonly used for heating and cooling with floor mounted systems, but can also be used with low temperature radiators or fan coils, even in combined and multi-zone combinations.

Air/air multi-split, a classic solution for the summer air conditioning of apartments and villas but also for heating and cooling offices, shops and small service sector applications in general.

Air/water multi-split mixed with air/air, an unusual solution that offers a extremely wide spectrum of applications. With this system we can create a floor mounted system with two zones and at the same time air condition a cellar and loft conversion with an air/air unit suited to these spaces: wall mounted, floor mounted with two-way flow or maybe even ductable.

I S

ER

IS

ER

IES

IES

8 www.argoclima.com

Outdoor units

Technical specifications for outdoor units

Refrigerant flow/volume regulation via centralised PID control system acting on a vectorial inverter and electronic expansion valves.

SVPWM180°, vectorial inverter with sensor less 180° PWM; this is a purely sinusoidal inverter with extremely low electromagnetic noise emissions. It provides constant control of the permanent magnet synchronous motors throughout their 360° revolution (180°+180°). This optimises torque, a key factor in motor control for compressors in particular, thus providing excellent performance in terms of output, efficiency and quietness, especially at low rotational speeds.

Multi-processor platform based on the client/server model, with an operating system controlling the motors and microprocessors dedicated to application management fitted in the outdoor and indoor units.

Standard RS485 bus communication via screened bi-polar cable: the highest level of communication security is ensured thanks to a balanced interface normally used for industrial applications. The bus provides an address for each unit and can be wired either as a bus or in a star configuration starting from the outdoor unit. This allows the system to be expanded and developed whilst still ensuring compatibility between units. One advantage of the RS485 bus is the possibility of supplying the units in the system with power either in a centralised manner or each to unit independently.

The range of outdoor operating temperatures is very wide; regulations require full operation from -15°C to +43°C but the iSERIESTM exceeds this: we have heat pump installations working at up to -30°C in Nordic areas and cooling installations in desert regions operating in outside temperatures of over 50°C. The iSERIESTM control system is able to protect itself and implements operational shut down only when the temperature reaches -50°C, practically absurd conditions for a heat pump.

I SE

RIE

SI

SE

RIE

S

9www.argoclima.com

Compressor Liquid ice prevention; a dedicated heater coil, controlled by the electronics and software in the outdoor unit controller, cuts in to prevent the compressor Liquid from freezing when the system is inactive in stand by and outdoor temperatures require it.

Ice prevention at the base of the outdoor unit; a dedicated electric heater coil is fitted indoor the metal base of the outdoor unit and is activated by the software when temperature conditions require in order to prevent the formation of ice.

Non Stop Operation and Intelligent Defrost; the prevention and elimination of ice on the heat exchanger in the outdoor unit is an essential process for an air-condensed heat pump. Thanks to its special control algorithms, iSERIESTM carries out this task in an intelligent way and, unless strictly necessary, without inverting the refrigerating cycle and therefore with a continuous (albeit reduced) heat supply to the heated area.

Compact and sophisticated electronics, built using SMD technology, resin coated for protection from atmospheric

agents and equipped with certified hardware protection circuits.

Diagnostic system for the easy identification of any technical faults, with data logging for technicians accessed directly from bus RS485.

BootLoader for software updates for outdoor and indoor units, with no risk of losing flash eprom data.

Automatic restart following power black outs, with the same operating parameters as before and restart protected against excess pressure.

Heat exchangers in high quality copper/

aluminium with inorganic hydrophilic

aluminium, which does not emit odours and provides top performance in heat exchange output and efficiency.

Maximum installation flexibility, thanks to the specifications governing pipe length and height difference between units.

Rust-proof treatment, providing the best protection against corrosion and rust formation even under extreme conditions such as in saline mist.

I S

ER

IS

ER

IES

IES

AEI1G30, the smallest outdoor unit in the iSERIESTM range, designed for mono-split applications but not only for hiwall and not only for air/air applications (EMIXTM).AEI1G30 is very compact, its heat output is nearly 4 kW and it is built to withstand the worst atmospheric conditions without corrosion. It has a plastic front grille resistant to UV rays covering the entire surface and a silver logo with the brand and a Made in Italy logo. The elegant pipe cover completes the unit, which is one of the most compact and quiet available on the market.

AEI1G40 and 50 are built using the same chassis for mono/dual solutions up to 6 kW.Its size provides high performance whilst still remaining quite compact. Corrosion resistant metals prepared for the worst atmospheric conditions and plastics resistant to UV rays complete these particularly quiet outdoor units.

10 www.argoclima.com

AEI1G65, despite its heat rating of over 8.5 kW, this unit is compact, strong and quiet. Like the other units in the iSERIESTM range, this unit is designed to withstand the worst conditions. It can be used for mono, dual and triple solutions with a wide range of air and/or water indoor units.

AEI1G80, mono, dual, triple and quadruple configurations in a single outdoor unit compatible with all the multifunction indoor units in the iSERIESTM range, and with a heat output of up to 11 kW. Corrosion resistant metals impervious to saline mist, UV ray resistant plastic and concealed pipe attachments complete this excellent and quiet unit.

AEI1G110*, over 13 kW in a compact chassis with a single fan, for mono, dual, triple and quadruple applications with high heat outputs, this unit is suitable for fully integrated primary solutions for heating and cooling offices and family homes. Corrosion resistant metals impervious to saline mist and UV ray resistant plastic; a top-of-the-range outdoor unit, quiet and flexible with an excellent heat output.

*available in 2012

I SE

RIE

SI

SE

RIE

S

11www.argoclima.com

Technical Data

Outdoor units

The technical data provided refers to European Standard EN14511, as per Directive 2002/31/CEN.B. Provisional data used at the time of printing

AEI1G30Specifications Units Cooling Heating

Capacity nominal (min-max) kW 2,65 (1,37-3,6) 2,75 (0,93-3,32)

Energy class ABCDEFG A A

E.E.R. / C.O.P. (kW/kW) 3,96 4,82

Fan speed N° self modulating

Sound pressure O.U. (max.) dB(A) 40

Electrical power supply V/Ph/Hz 230/1/50

Power input kW 0,67 0,57

Annual energy consumption (500h)-Dir. 2002/31/EC kWh 335 -

Compressor type Single Rotary

Refrigerant type R410A

Liquid pipe diameter mm (inch") 6,35(1/4”)

Gas pipe diameter mm (inch") 9,52(3/8”)

Length of pipes (with standard charge) m 7,5

Length of pipes (with additional charge) m 15

Maximum height difference IU/OU (outdoor unit above or below) m 10

Net weight Kg 35

Net dimensions (H./W./D.) mm 540x700x265

AEI1G40Specifications Units Cooling Heating

Capacity nominal (min-max) kW 3,50 (1,25-4,25) 3,90 (1,20-5,20)

Energy class ABCDEFG A A

Nominal E.E.R. / C.O.P. (kW/kW) 3,68 4,19

Fan speed N° self modulating

Sound pressure O.U. (max.) dB(A) 44

Electrical power supply V/Ph/Hz 230/1/50

Power input kW 0,950 0,930

Annual energy consumption (500h)-Dir. 2002/31/EC kWh 475 -

Compressor type Rotary

Refrigerant type R410A

Liquid pipe diameter mm (inch") 6,35(1/4”)

Gas pipe diameter mm (inch") 9,52(3/8”)

Length of pipes (with standard charge) m 15

Length of pipes (with additional charge) m 15 (no additional charge)

Maximum height difference (outdoor unit above) m 7

Maximum height difference (indoor unit above) m 7

Net weight Kg 39

Net dimensions (H./W./D.) mm 630x895x345

I S

ER

IS

ER

IES

IES

Technical Data

12 www.argoclima.com

The technical data provided refers to European Standard EN14511, as per Directive 2002/31/CEN.B. Provisional data used at the time of printing

AEI1G50BSpecifications Units Cooling Heating

Capacity nominal (min-max) kW 4,55 (0,84-5,18) 5,19 (0,95-6,00)

Energy class ABCDEFG A A

E.E.R. / C.O.P. nominal value (min.-max.) (kW/kW) 3,35 (4,20-2,93) 4,29 (5,94-3,43)

Fan speed N° self modulating

Sound pressure O.U. (max.) dB(A) 41

Electrical power supply V/Ph/Hz 230/1/50

Power input nominal (min-max) kW 1,360 (0,200-1,770) 1,210 (0,160-1,750)

Annual energy consumption (500h)-Dir. 2002/31/EC kWh 680 -

Compressor type Twin Rotary

Refrigerant type R410A

Liquid pipe diameter mm (inch") 6,35(1/4”)

Gas pipe diameter mm (inch") 9,52(3/8”)

Length of pipes (with standard charge) m 15 tot. Dual / 7.5 Mono

Length of pipes (with additional charge) m 30 tot. Dual / 20 Mono

Length of pipes per unit (with standard charge) m 12 (Dual)

Length of pipes per unit (with additional charge) m 25 (Dual)

Maximum height difference IU/OU (outdoor unit above or below) m 20 tot. (max. 10m I.U.)

Net weight Kg 56,5

Net dimensions (H./W./D.) mm 630x895x345

AEI1G65Specifications Units Cooling Heating

Capacity nominal (min-max) kW 6,50 (1,57-8,71) 7,30 ( 1,82-8,67)

Energy class ABCDEFG A A

E.E.R. / C.O.P. nominal value (min.-max.) (kW/kW) 3,25 (3,78-3,00) 4,32 (5,05-3,82)

Fan speed N° self modulating

Sound pressure O.U. (max.) dB(A) 40

Electrical power supply V/Ph/Hz 230/1/50

Power input nominal (min-max) kW 2,0 (0,415-2,90) 1,69 (0,36-2,27)

Annual energy consumption (500h)-Dir. 2002/31/EC kWh 1000 -

Compressor type Twin Rotary

Refrigerant type R410A

Liquid pipe diameter mm (“) 6,35(1/4”)

Gas pipe diameter mm (“) 9,52(3/8”) / 12,77(1/2”)

Length of pipes (with standard charge) m 30 tot. Dual-Triple / 20 mono

Length of pipes (with additional charge) m 45 tot. Dual-Triple / 35 mono

Length of pipes per unit (with standard charge) m 25 (Dual) 20 (Triple)

Length of pipes per unit (with additional charge) m 30 (Dual) 25 (Triple)

Maximum height difference IU/OU (outdoor unit above or below) m 10 tot. Dual-Triple / 10 mono

Net weight Kg 64

Net dimensions (H./W./D.) mm 735 x 1030 x 400

AEI1G80Specifications Units Cooling Heating

Capacity nominal (min-max) kW 8,15 (1,60-9,62) 9,21 ( 1,70-11,20)

Energy class ABCDEFG A A

Nominal E.E.R. / C.O.P. (kW/kW) 3,70 4,22

Fan speed N° self modulating

Sound pressure dB(A) 47

Electrical power supply V/Ph/Hz 230/1/50

Power input kW 2,20 2,18

Annual energy consumption (500h)-Dir. 2002/31/EC kWh 1100 -

Compressor type Twin Rotary

Refrigerant type R410A

Liquid pipe diameter mm (“) 6,35(1/4”)

Gas pipe diameter mm (“) 3 x 9.52 (3/8”) / 1 x 12.77 (1/2”)

Length of pipes (with standard charge) m 30 tot.

Length of pipes (with additional charge) m 65 tot. multi / 50 mono

Length of pipes per unit (with standard charge) m 30

Length of pipes per unit (with additional charge) m 50

Maximum height difference IU/OU (outdoor unit above or below) m 30 tot. multi / max. 10 per unit

Net weight Kg 73

Net dimensions (H./W./D.) mm 835x1190x400

I SE

RIE

SI

SE

RIE

S

13www.argoclima.com

Combinations

APPLICATIONS

AIR / AIR COMBINATIONS

AIR/ WATER COMBINATIONS

*Connect to ports A and B inserting the integrated accumulator using the bypass provided with AEI1G65

AEI1G 30 AEI1G 40 AEI1G 50B AEI1G 65 AEI1G 80 Air/Air X X X X X

Air/Water X X X

Air/Air and Air/Water X X X

AEI1G 30 AEI1G 40 AEI1G 50B AEI1G 65 AEI1G 80

Mono A A B B B

Mono C C

Dual A+A A+A* A+A

Dual A+B A+B A+B

Dual B+B A+C

Dual B+B

Triple A+A+A A+A+A

Triple A+A+B A+A+B

Triple A+B+B

Quadruple A+A+A+A

Quadruple A+A+A+B

AEI1G 50B AEI1G 65 AEI1G 80

HKBE HKBE HKCE

AEI1G 30 AEI1G 40 AEI1G 50B AEI1G 65 AEI1G 80

Wall AWIA S8 W/B mono mono

Wall AWIA S87 W/B mono multi multi multi

Wall AWIA S7F mono multi multi multi

Floor AFIA S11 mono mono multi multi multi

Floor/Ceiling FCIA S8 mono mono multi multi multi

Floor/Ceiling-recess SDIA S8 mono mono multi multi multi

Cassette ASIA S8 mono mono multi multi multi

Wall AWIB S9 mono/multi mono/multi mono/multi

Floor AFIB S11 mono/multi mono/multi mono/multi

Floor/Ceiling FCIB S9 mono/multi mono/multi mono/multi

Floor/Ceiling-recess SDIB S9 mono/multi mono/multi mono/multi

Cassette ASIB S9 mono/multi mono/multi mono/multi

Hydraulic module HK BE mono mono/multi

Ducted ADIC S10 mono mono mono/multi

Cassette ASIC S10 mono mono/multi

Hydraulic module HK CE mono/multi

SIZE A

SIZE B

SIZE C

I S

ER

IS

ER

IES

IES

(Ln) Individual lengths

(L) Individual lengths

14 www.argoclima.com

AEI 1G 30/40

L

AEI 1G 50

L1

L

L2

L

L

AEI 1G 65

AEI 1G 80

L1

L1

L2

L2

L3

L3

L4

Maximum pipe lengths and maximum distances

between outdoor unit and indoor units

The AEI1G50 outdoor unit, equipped with a standard charge of refrigerant (preloaded in the factory), allows for a maximum pipe length of 7.5 metres in mono configuration and up to 15 metres in dual configuration. By adding refrigerant (20 grams per metre in mono configuration and 15 grams per metre in dual configuration), the maximum length is extended to 20 metres in mono configuration and 30 metres in dual configuration.In the event of dual configurations it should be remembered that each of the two indoor units can be positioned at a different distance from the outdoor unit. If the maximum distance of the first indoor unit from the outdoor unit is 12 metres, the second indoor unit must be placed at a maximum distance of 3 metres from the outdoor unit. This is because the maximum pipe length (15 metres), must never be exceeded. Of course in the event of additional refrigerant, the maximum distance of the first indoor unit can be up to 25 metres, and the second, 5 metres.Similar concepts can also be applied to outdoor units AEI1G65 and AEI1G80, and the same shall apply for future outdoor units in the iSeries range.The table below combined with the diagram allows you to easily identify the maximum values for the pipe lengths / maximum distances between outdoor and indoor units.

Height differences between outdoor and indoor

units and between indoor units

The maximum height difference between the outdoor unit and indoor unit/s does not depend on the distances and/or the pipe lengths described above. It depends instead on the total height difference between the various units (both outdoor and indoor) that make up the split or multi-split system.In multi-split configurations there is also a relationship between the maximum height difference between the outdoor unit and indoor units (sum of height differences). For example, if the total maximum height difference between the outdoor unit and indoor units as declared by the manufacturer is 10 metres and the maximum height difference between the two indoor units is 5 metres, in a dual configuration with the outdoor unit on the ground floor, the first indoor unit can be installed at up to 7 metres above (or below), but the second unit may only be fitted a maximum of 3 metres above (or below). This is so as not to exceed 10 metres (7+3 = 10) and at the same time to not exceed the 5 metres of maximum height difference between the two indoor units (7-3 = 4).On the other hand, it is not possible to position the first indoor unit at 8 metres and the other at 1 metre from the outdoor unit. This is because even though the sum of height differences is less than the maximum height difference of 10 metres (8+1 = 9), the height difference between the two indoor units would however reach 7 metres, exceeding the maximum permitted height difference. Where the same dual configuration outdoor unit is positioned at a height in between the two indoor units, the first indoor unit can also be installed one metre below the outdoor unit. In this case the second indoor unit can be installed at a maximum of 4 metres above the outdoor unit because the maximum height difference of 5 metres between indoor units cannot be exceeded. With this type of installation the two indoor units are in fact usually placed at a height difference of 2.5 metres with respect to the outdoor unit.

Standard charge Additional charge

Outdoor unit Configuration Tot L Max L Tot L Max L

AEI1G30 mono-split 15 - 15 -

AEI1G40 mono-split 15 - 15 -

AEI1G50B mono-split 7,5 - 20 -

AEI1G50B dual-split 15 12 30 25

AEI1G65

mono-split 20 - 35 -

dual-split 30 25 45 30

triple-split 30 20 45 25

AEI1G80

mono-split 30 - 50 -

dual-split 40 30 65 30

triple-split 40 30 65 30

quadruple-split 40 30 65 30

Tot L = total length of pipes, given by the sum of pipe lengths for each indoor unitMax L = maximum pipe length per single indoor unit, whether it is no. 1, 2, 3….

Maximum height difference (sum of height differences)AEI1G30 and AEI1G40 = 7 m

AEI1G50 = 20 m

AEI1G65 = 30 m

AEI1G80 = 40 m

Maximum height difference between two indoor units (only for multi-split systems)AEI1G50 = 5 m

AEI1G65 = 5 m

AEI1G80 = 5 m

I SE

RIE

SI

SE

RIE

S

Indoor units

15www.argoclima.com

Technical specifications for indoor units

Every indoor unit in the iSERIESTM system has its own specific features but there are also features common to all units in the range, these are listed here below.

Dynamic Cold Draft, an active protection system preventing the emission of air that is noticeably colder than ambient temperature during heating operation and particularly during defrost stages.

Antifreeze, this protection system prevents the formation of ice on the indoor unit heat exchanger when the system is working in cooling mode and there are particular temperature and humidity conditions.

Temperature settings from +10°C to +32°C both in cooling and heating modes; the units can therefore be used for indoor low ambient temperature applications such as in cellars, server rooms and radio stations... They can also be used to maintain a minimum temperature in spaces that are unused during weekends such as offices and shops, or places that are unused during the week such as holiday homes in the mountains or at the seaside...

iFEEL function, a comparative function that ensures optimum temperature settings based on the values read at the remote control sensor, the sensor in the indoor unit and the resulting ambient temperature stratification conditions, which are always different from one room to another.

Wide range IR receiver, this receives the remote control signal even under difficult conditions. It is equipped with a noise canceller for complete immunity from interference generated by low energy consumption fluorescent bulbs.

Hardware or software addressing of units for recognition on communication bus RS485.

Remote control addressing for the management of one or more grouped indoor units, up to a maximum of four units. This function is useful where several indoor units are situated in a large space (open space offices, hotel reception rooms, restaurants, etc...), and need to be controlled either by one or several remote controls.

I S

ER

IS

ER

IES

IES

16 www.argoclima.com

Five operating modes: automatic, cool, heat, dehumidify and fan.

Night Function for maximum operating economy during the night without compromising comfort.

High Power Function, when maximum power is required straight away.

Active/passive air filters: all air/air units are equipped with washable mesh filters and can be fitted with an activated charcoal filter; some units are fitted as standard with a titanium dioxide photocatalytic anti-bacterial filter, activated via remote control by invisible dedicated LEDs fitted indoor the unit, fully compliant with EU regulations concerning UV emissions.

Intelligent air flap control based on operating mode, which when combined with the iFEEL function offers the maximum in comfort to counter air temperature stratification effects.

Automatic fan (or manual fan) to provide maximum heat (when required) and the right amount of cool, without creating annoying cold air draughts or excessive amounts of hot air.

Timer for programming the operating times of each individual indoor unit, with weekend* and holiday* controls.

Wireless and wired universal remote control for all iSERIESTM indoor units, with multi-function keypad, LCD graphic display, wall mount and wired* connection.

Elegant ergonomic interface with discreet micro LEDs that can be deactivated via remote control, particularly useful for those that prefer complete darkness at night.

Protective grilles, which offer the maximum in safety in compliance with standard EN60335. This allows for installation even at low heights where children could otherwise potentially touch moving parts such as fans and motors.

* this last function is available with the new remote control for 2012

I SE

RIE

SI

SE

RIE

S

17www.argoclima.com

Heat exchangers in high quality copper/aluminium with inorganic hydrophilic aluminium, which does not emit odours and provides top performance in heat exchange output and efficiency.

Plastic materials with high quality looks and functional properties (improved thermal stability). As green as possible thanks to the use of noble acrylics such as PMMA, pure ABS for the parts on view and recycled PS for the internal structures.

Hydrokit with heat exchanger with plates made from AISI316L stainless steel for heat exchange between the refrigerant and water, built-in module for additional electrical heating, automatically controlled by software in three steps, controlled by thermal-magnetic switches that can be deactivated manually, safety thermostats, pressure switch, high performance water pump and water flow rate control device.

Controller for hydrokit , with climatic curve control and control of the various applications of the hydronic circuit (floor, fan coils, radiators, mixed...), with the possibility of separation into areas with different settings.

Wide range of hydronic accessories to suit various different system configurations.

Generation of domestic hot water using the EMIXTM module, the internal unit for the iSERIESTM system, which is able to provide hot water from a thermo-dynamic source all year round. EMIXTM will become available in 2012 and will have its own illustrated manual explaining the functions and operating modes in connection with the iSERIESTM system.

I S

ER

IS

ER

IES

IES

18 www.argoclima.com

A8, a wall-mounted indoor unit with a distinctive design, ideal for modern spaces

and also compatible with more conventional styles. Combines easily with many

different styles and colours found in the office and at home.

I SE

RIE

SI

SE

RIE

S

19www.argoclima.com

very quiet:

only 21 dB(A)Heat exchanger in odourless inorganic

hydrophilic aluminium

This filter uses the oxidising power of Titanium Dioxide (TiO

2) to destroy bacteria and inhibit viruses. It also

effectively reduces dust and dirt particles and helps to prevent unpleasant odours.

Organic compounds, odours, bacteria, viruses...

A8 is designed to provide high energy efficiency and has one very important feature: it can be recess fitted using the dedicated wall mounting kit.

84 mm

The front panel made from PMMA, a prized acrylic material, is dual coated on the back and available in satin white or carbon fibre black; the transparent border along the panel perimeter creates a bright frame that responds to colour changes in the environment. The horizontal central strip in silver conceals the noiseless remote control signal receiver and the extremely elegant blue and white micro LEDs. These are very discreet and can also be deactivated using a function developed specifically for those that prefer complete darkness at night.

A8 is also easy to install, thanks to the possibility of being able to connect the refrigerant pipes either to the horizontal compartment or to the right side; the bilateral condensation discharge pipe and the possibility of fitting the unit at below two metres in height (thanks to the protection grille), complete the flexibility of this high quality indoor unit.

A8 is available in size A, and at 21 dB(A) is extremely quiet. The unit is equipped with an active photocatalytic filter, which is able to significantly reduce the bacterial load in the environment thanks to the titanium dioxide oxidation process activated by completely concealed special UV LEDs that are fully compliant with EU standards.

Titanium Dioxide filters and Air QualityI

SE

RI

SE

RIE

SIE

S

20 www.argoclima.com

Elegant and discreet, available in sizes A (A7) and B (A9), an indoor unit to suit

all tastes, suitable for all settings both in terms of design and heat output.

I SE

RIE

SI

SE

RIE

S

21www.argoclima.com

The optional activated charcoal filter is comprised of a layer of synthetic material folded to increase the filtering surface area and treated with a professional anti-bacterial solution, combined with an activated charcoal mesh. Activated charcoal is a material mainly made up of carbon in the form of graphite micro crystals treated in such a way as to create a porous structure with a vast internal surface area. When the forced air flow passes through the filter element, the charge of static energy allows the filter to trap even the smallest particles of pollutants and allergens, down to a size of 0.01 microns. The activated charcoal layer attracts and absorbs the organic molecules responsible for unpleasant odours, eliminating them completely.

The casing for model A7/A9 is treated using a photo engraving technique to obtain a satin effect on the plastic, this is done during the injection stage and no further treatments are applied. You can see the quality of the material and manufacturing process used with the naked eye, this sets the A7/A9 unit apart from other white wall-mounted indoor units.

A7/A9 allows condensation discharge to the right or left, it has LEDs that can be deactivated and washable filters, it is compact and easy to install.

very quiet: only 23 dB(A)Heat exchanger in odourless inorganic hydrophilic aluminium

Mesh filters with optional odour-capturing activated charcoal filter I

SE

RI

SE

RIE

SIE

S

22 www.argoclima.com

A refined console for low wall installation, at just a few centimetres from the floor and

with two-way air flow, up and down, for maximum comfort in summer and winter.

I SE

RIE

SI

SE

RIE

S

23www.argoclima.com

AF is very sophisticated, it is equipped with a DC motor (DCM), and in stand by consumes only 70 mW. It is equipped with a humidity sensor that is used to differentiate the use of the two air flows based on the sensed temperature index.

AF is available in sizes A and B, whilst still maintaining the same structure and dimensions. It filters and purifies the air using a washable mesh filter and a titanium dioxide photocatalytic filter that can be activated via remote control. At 22 dB(A), the unit is extremely quiet thanks to its specially-designed structure and two tangential fans managed by inverter-controlled DC motors.

AF is the newest model and is also the first in its class within the iSERIESTM range of indoor units. Compact and made from pure ABS, it is well suited for installation under windows or mid-wall, occupying the smallest space possible.

LED operation can be deactivated by remote control

LED operation can be deactivated by remote control

very quiet: only 22 dB(A)

I S

ER

IS

ER

IES

IES

24 www.argoclima.com

FC and SD, two versions of the same unit, reversible for floor or ceiling instal-

lation, they can be fitted on view (FC) or concealed in dedicated spaces (SD)

created using plasterboard or wood or in false ceilings.

I SE

RIE

SI

SE

RIE

S

25www.argoclima.com

very quiet:

only 24 dB(A)Heat exchanger in odourless inorganic

hydrophilic aluminium

Easy installation and condensation discharge

Easy maintenance

Ceiling installation

LED operation can be deactivated by remote control

Condensation anti-drip system

Fits anywhere!!!

ONLY

18.9 cm!!!

Vertical installation

FC and SD are available in sizes A and B, whilst still maintaining the same structure and dimensions. They are easy to install and maintain thanks to washable filters that are easy to access on both versions. SD, despite being designed for recessed and therefore concealed fitting, can be controlled by the iSERIESTM universal remote control in either wireless or wired mode.

The depth of only 19 cm and quiet operation at 24 dB(A), make these two iSERIESTM units an excellent solution for villas, offices, hotel rooms, restaurants and public spaces etc.

I S

ER

IS

ER

IES

IES

AS, the cassette unit for false ceilings that we can often observe above our heads

in public spaces, offices, shops and restaurants.

It is certainly also suitable for private dwellings as it was originally designed with

this application in mind, however it is more common to see it used in service

sector applications.

It is certainly also suitable for private dwellings as it was originally designed with

this application in mind, however it is more common to see it used in service

sector applications.

26 www.argoclima.com

I SE

RIE

SI

SE

RIE

S

27www.argoclima.com

Easy installation and discharge

Perfect integration!

Body in anti-corrosion metal Simple and convenient maintenance

Flocked anti-condensation flaps

very quiet:

only 35 dB(A)Heat exchanger in odourless inorganic

hydrophilic aluminium

As with all the other units in the iSERIESTM range, AS is controlled using the universal remote control. In the contexts in which this cassette unit is installed the remote control is able to express some of its more special features, such as the option for wired connection instead of wireless control and the ability to control groups of units, which is very useful for open space offices, restaurants, and hotel reception areas.

Available in sizes A and B, and with slightly larger dimensions (80x80) also in size C, this unit is built with great attention to detail: insulated metal, four flocked anti-condensation flaps, carefully calibrated fan, quality plastic grille and a large filter that is easy to access for cleaning.AS is designed for air exchange with the outside, which is mandatory for installations in public spaces, and is equipped with a condensation discharge pump.

ASIA/ASIB ASIC

I S

ER

IS

ER

IES

IES

28 www.argoclima.com

AD, the high prevalence ductable unit, to be combined with purpose built plenums

with or without the aid of the three-way duct built into the unit.

I SE

RIE

SI

SE

RIE

S

29www.argoclima.com

AD, as with the cassette units, this unit is mainly designed for use in service sector applications and is built with great care from carefully selected materials.

Available in size C, it is equipped with high quality centrifugal fans and a condensation discharge pump. It is also fitted with washable filters that are easy to access and can be controlled using the iSERIESTM universal remote control in wired or wireless mode.

Plenum for channelling the air into 3 spaces

Perfect distribution

Removable filters

Standard integration

I S

ER

IS

ER

IES

IES

30 www.argoclima.com

The iSERIESTM system is able to control air-condensed indoor units simultaneously with Hydrokit to create a mixed air/water and air/air system. The wide range of possibilities for use both as a mixed system and as a conventional split inverter air/water heat pump system, should be very interesting to installation technicians who will discover the unique versatility of the iSERIESTM system.

Hydrokit, installed indoor the building as if it were a wall-mounted boiler, is equipped with high quality plate heat exchangers made from AISI316L stainless steel, a high efficiency water pump and a module for additional electrical heating with three power steps (2+2+2 kW). The system is fully controlled by the unit’s software according to heat requirements but can also be manually deactivated using the dedicated thermal-magnetic switches. A pressure gauge displays the water pressure in the circuit and there are also safety pressure switches and a device that controls the water flow rate.

Hydrokit HKE, available in sizes B and C, is the indoor unit to be combined with

the iSERIESTM outdoor units to create heating and air conditioning solutions

with floor, wall or ceiling mounted radiator systems.

I SE

RIE

SI

SE

RIE

S

31www.argoclima.com

EMIXTM is the innovative indoor unit in the iSERIESTM range, able to provide domestic hot

water from a thermo-dynamic source all year round, i.e. independently of the system’s

operating mode.

EMIXTM works simultaneously with the other units in the system, both in air/air and air/water configurations or in mixed air/air and air/water combinations, an absolute first.

EMIXTM will become available in 2012 and will have its own illustrated operating manual demonstrating the possible combinations with other indoor units and connection configurations with outdoor units in the iSERIESTM range.

In addition to mixed air/water and air/air configurations, unique to the iSERIESTM system, Hydrokit is also able to control many hydronic applications:

heating and air conditioning with mono and multi-zone floor, wall or ceiling mounted radiator systems;heating using low temperature radiators, also in combination with floor mounted radiator systems;air conditioning using hydronic terminal units or fan coils, also in combination with floor mounted radiator systems.

It should be remembered that the installation of air/air indoor units in the same area as a floor mounted radiator system avoids the need to install dehumidifiers for the cooling cycles and accelerates arrival at the desired set point in both heating and cooling modes.

Hydrokit is provided with an area controller, a sensor to be fitted on the building exterior and a water filter. The controller manages both the climatic curve and the entire hydronic system; it can be connected to other similar controllers to manage separate areas with the aid of the multi-zone module. Other accessories for the hydronic system are available on request to satisfy special requirements.

I S

ER

IS

ER

IES

IES

All air conditioner operating parameters can be controlled from the remote control:

operating modes (auto or cooling only, heat pump only, dehumidification only,

fan only), 1h and 24h timer, desired temperature, ambient temperature reading,

TiO2

filter activation (where fitted), fan speed, flap oscillation for optimum air

distribution in the room and economy or night functions. Many operations can

be set automatically or managed when needed, including the deactivation of the

LED indicators for those that prefer complete darkness at night.

Universal Digital Remote Control

be set automatically or managed when needed, including the deactivation of the

LED indicators for those that prefer complete darkness at night.

I SE

RIE

SI

SE

RIE

S

32 www.argoclima.com

Wide display with graphic symbols and alphanumeric indicators.

Built-in temperature sensor.

Dual transmitter

Wide range of operation. The presence of a dual infrared transmitter

ensures a very wide range of operation: just place the remote control

where you like for “made-to-measure” comfort in that area.

iFeel function

a comparative function that ensures optimum temperature settings

based on the values read at the remote control sensor, the sensor in

the indoor unit and the resulting ambient temperature stratification

conditions, which are always different from one room to another.

when maximum power is required straight away.

The remote control can be set to control four different units in an open space for unified control, or customised according to

temperature, timer, operating mode, and all other functions.

iFlap Function

The air flow can be released into the room

in an “intelligent” way based on whether

the unit is set to heating or cooling mode,

thanks to a special system that controls

the oscillation of the horizontal flap.

One for all One to One

Adjustable set point from 10° to 32° C

both in cooling and heat pump modesI

SE

RI

SE

RIE

SIE

S

33www.argoclima.com

34 www.argoclima.com

Technical Data

Indoor units

MODEL AWIAS87 W/B AWIAS8 W/B

Specifications Units

Air flow rate I.U. (sl.-l.-m.-h.) m³/h 250-410-480-600 250-410-480-600

Dehumidification l/h 1,5 1,5

Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 21-29-36-39 21-29-36-39

Electrical power supply V/Ph/Hz 230/1/50 230/1/50

Power input kW 0,031 0,031

Current consumption A 0,13 0,13

Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)

Gas pipe diameter mm (“) 9,52(3/8”) 9,52(3/8”)

Net weight I.U. kg 10,5 10,5

Net dimensions I.U. (H./W./D.D of recess-fitted I.U.) mm 305x895x195/110 305x895x195/110

I SE

RIE

SI

SE

RIE

S

35www.argoclima.com

Dati Tecnici

MODEL AWIA S7F AWIB S9

Specifications Units

Air flow rate I.U. (sl.-l.-m.-h.) m³/h 390-430-470-450 410-580-710-880

Dehumidification l/h 1,5 2,0

Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 23-29-36-39 29-35-43-47

Electrical power supply V/Ph/Hz 230/1/50 230/1/50

Power input kW 0,031 0,086

Current consumption A 0,13 0,40

Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)

Gas pipe diameter mm (“) 9,52(3/8”) 12,7(1/2”)

Net weight I.U. kg 8 12

Net dimensions I.U. (H./W./D.) mm 270x805x215 285x995x240

MODEL AFIA S11 AFIB S11

Specifications Units

Air flow rate I.U. (sl.-l.-m.-h.) m³/h 450-500-590-700 615-665-760-830

Dehumidification l/h 1,3 2,3

Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 22/26/30/37 28/30/37/45

Electrical power supply V/Ph/Hz 230/1/50 230/1/50

Power input kW 0,017 0,019

Current consumption A 0,07 0,08

Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)

Gas pipe diameter mm (“) 9,52(3/8”) 12,7(1/2”)

Net weight I.U. kg 18 18

Net dimensions I.U. (H./W./D.) mm 600x750x220 600x750x220

I S

ER

IS

ER

IES

IES

36 www.argoclima.com

Dati Tecnici

MODEL FCIA S8 FCIB S9

Specifications Units

Air flow rate I.U. (sl.-l.-m.-h.) m³/h 450-500-590-700 615-665-760-830

Dehumidification l/h 1,3 2,3

Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 24-26-30-37 35-40-46-49

Electrical power supply V/Ph/Hz 230/1/50 230/1/50

Power input kW 0,037 0,075

Current consumption A 0,17 0,33

Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)

Gas pipe diameter mm (“) 9,52(3/8”) 12,7(1/2”)

Net weight I.U. kg 23,5 23,5

Net dimensions I.U. (H./W./D.) mm 680x900x190 680/900/190

MODEL SDIA S8 SDIB S9

Specifications Units

Air flow rate I.U. (sl.-l.-m.-h.) m³/h 300-340-380-470 470-520-600-680

Dehumidification l/h 1,3 3,3

Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 24-26-30-37 35-40-46-49

Electrical power supply V/Ph/Hz 230/1/50 230/1/50

Power input kW 0,037 0,075

Current consumption A 0,17 0,33

Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)

Gas pipe diameter mm (“) 9,52(3/8”) 12,7(1/2”)

Net weight I.U. kg 25 25

Net dimensions I.U. (H./W./D.) mm 585x890x190 585x890x190

I SE

RIE

SI

SE

RIE

S

37www.argoclima.com

MODEL ADIC S10

Specifications Units

Air flow rate I.U. (sl.-l.-m.-h.) m³/h 500/600/700/1000

Dehumidification l/h 2,5

Fan speed N° Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 35-40-46-49

Electrical power supply V/Ph/Hz 230/1/50

Power input kW 0,114

Current consumption A 0,51

Liquid pipe diameter mm (“) 6,35(1/4”)

Gas pipe diameter mm (“) 12,7(1/2”)

Net weight I.U. kg 23,5

Net dimensions I.U. (H./W./D.) mm 680 x 900 x 190

MODEL ASIA S8 ASIB S9

Specifications Units

Air flow rate I.U. (sl.-l.-m.-h.) m³/h 470-500-600-700 500-530-630-750

Dehumidification l/h 1,2 2,3

Fan speed N° Auto + 3 remote control settings Auto + 3 remote control settings

Sound pressure I.U. (sl.-l.-m.-h.) dB(A) 35-37-40-44 35-37-40-44

Electrical power supply V/Ph/Hz 230/1/50 230/1/50

Power input kW 0,087 0,087

Current consumption A 0,41 0,41

Liquid pipe diameter mm (“) 6,35(1/4”) 6,35(1/4”)

Gas pipe diameter mm (“) 9,52(3/8”) 12,7(1/2”)

Net weight kg 19 20,5

Net dimensions I.U. (H./W./D.) mm 296x575x575 296x575x575

Net dimensions of grille (H./W./D.) mm 41x730x730 41x730x730

ASIC S10

680/840/1020/1140

3,6

Auto + 3 remote control settings

41/44/45/46

230/1/50

0,175

0,77

15,88(5/8”)

12,7(1/2”)

22

338x860x860

41x730x730

I S

ER

IS

ER

IES

IES

38 www.argoclima.com

Type

Applications

Outdoor Units

Indoor UnitsA

EI1G

30

AEI

1G40

AEI

1G50

B

AEI

1G65

AEI

1G80

AEI

1G11

0

Wal

l

Floo

r

Floo

r/C

eilin

g

Floo

r/R

eces

s-Fi

tted

Cei

ling

Cas

sett

e

Duc

ted

Hyd

roK

it

Uni

t for

DH

W

air/air mono-split x x x x x x x x x x x x

air/water mono-split

domestic hot water x x x

one floor area x x x x x

two floor areas x x x x x

one fan coil area x x x x xone floor area and one fan coil area x x x x xone floor area and one radiator area x x x x x

one radiator area x x x x xone radiator area and domestic hot water

x x x x x

air/air multi-split x x x x x x x x x x

mixed multi-split

air/air and domestic hot water

x x x x x x x x x x x

air/air and air/water x x x x x x x x x x xair/air, air/water and domestic hot water

x x x x x x x x x x x

I SE

RIE

SI

SE

RIE

S

iSERIESTM applications

39www.argoclima.com

AEI1G50B + HKBE

watertemperatureat inlet/outlet

outdoor air temperature

Heating Minimum Nominal Maximum

30/35 °C +7 °CKw 0,95 5,27 6,23

COP * 4,14

30/35 °C -7 °CKw * 4,02 4,73

COP * 2,38 *

45/50 °C +7 °CKw * 4,78 5,27

COP * 2,96 *

45/50 °C -7 °CKw * 3,10 3,65

COP * 1,92 *

40/45 °C +7 °CKw * 4,93 5,80

COP * 3,31 *

40/45 °C -7 °CKw * 3,70 4,35

COP * 2,3 *

20/25 °C +7 °CKw * 6,20 7,30

COP * 5,36 *

20/25 °C -7 °CKw * 3,16 3,72

COP * 2,73 *

Cooling Minimum Nominal Maximum

18/23 °C +35 °CKw 0,84 4,50 5,73

EER * 3,57 *

7/12 °C +35 °CKw * 3,15 3,47

EER * 1,97 *

I S

ER

IS

ER

IES

IES

* The data provided in the table was measured in accordance with European standard EN14511, which requires nominal efficiency and output tests.

In order to size systems correctly, the minimum output at standard conditions of +7°C and the maximum output values for all applications are also provided.

Preliminary data at catalogue date

40 www.argoclima.com

iSERIESTM applications

AEI1G65B + HKBE

watertemperatureat inlet/outlet

outdoor air temperature

Heating Minimum Nominal Maximum

30/35 °C +7 °CKw 1,82 8,20 9,33

COP * 4,2 *

30/35 °C -7 °CKw * 4,99 5,41

COP * 2,64 *

50/55 °C +7 °CKw * 5,65 6,50

COP * 2,63 *

50/55 °C -7 °CKw * 3,50 3,89

COP * 1,58 *

40/45 °C +7 °CKw * 7,10 7,60

COP * 3,2 *

40/45 °C -7 °CKw * 4,20 4,55

COP * 2,06 *

20/25 °C +7 °CKw * 8,70 9,45

COP * 5,48 *

20/25 °C -7 °CKw * 4,50 5,26

COP * 2,7 *

Cooling Minimum Nominal Maximum

18/23 °C +35 °CKw 1,57 6,00 7,00

EER * 3,6 *

7/12 °C +35 °CKw * 5,20 5,64

EER * 2,58 *

I SE

RIE

SI

SE

RIE

S

* The data provided in the table was measured in accordance with European standard EN14511, which requires nominal efficiency and output tests.

In order to size systems correctly, the minimum output at standard conditions of +7°C and the maximum output values for all applications are also provided.

Preliminary data at catalogue date

41www.argoclima.com

iSERIESTM applications

AEI1G80B + HKCE

watertemperatureat inlet/outlet

outdoor air temperature

Heating Minimum Nominal Maximum

30/35 °C +7 °CKw 1,70 9,42 11,30

COP * 4,03 *

30/35 °C -7 °CKw * 5,65 6,65

COP * 2,5 *

50/55 °C +7 °CKw * 6,40 7,53

COP * 2,49 *

50/55 °C -7 °CKw * 3,90 4,60

COP * 1,49 *

40/45 °C +7 °CKw * 8,10 9,55

COP * 3,06 *

40/45 °C -7 °CKw * 5,18 6,10

COP * 1,95 *

20/25 °C +7 °CKw * 10,24 12,05

COP * 5,03 *

20/25 °C -7 °CKw * 5,12 6,02

COP * 2,56 *

Cooling Minimum Nominal Maximum

18/23 °C +35 °CKw 1,60 7,98 9,40

EER * 4,01 *

7/12 °C +35 °CKw * 6,87 8,10

EER * 2,84 *

I S

ER

IS

ER

IES

IES

* The data provided in the table was measured in accordance with European standard EN14511, which requires nominal efficiency and output tests.

In order to size systems correctly, the minimum output at standard conditions of +7°C and the maximum output values for all applications are also provided.

Preliminary data at catalogue date

Notes:

42 www.argoclima.com

I SE

RIE

SI

SE

RIE

S

Made from ABS with a high-gloss pearl finish, Xfetto has a modern yet linear design that

fits well in any space.

Attractive, slim, versatile and…

with no outdoor unit

XF

ET

TO

XF

ET

TO

43www.argoclima.com

XF

ET

TO

XF

ET

TO

44 www.argoclima.com

AIR / AIR

Only 2 holes in the wall are needed…to connect the air-condensed Xfetto model with the outside, as long as the holes are in a perimeter wall. Xfetto air/air houses an outdoor unit within its single case and in order to operate correctly requires a constant exchange of air with the outside because it uses air to cool the condenser. This air exchange takes place via two 16 cm holes (1 intake hole and 1 outflow hole), to be made in the installation wall, which therefore must be a perimeter wall. Thanks to the special grilles the unit can be installed very easily even from indoor the room, through walls or structures up to 2 metres thick or directly onto large windows with no loss of performance... Xfetto is also designed to allow recessed wall installation and in this instance its visible depth is reduced to only 10 centimetres.

When Xfetto operates in cooling mode or dehumidification only, the condensation is released by internal evaporation in the condenser: therefore there is no need to provide a condensation discharge pipe for the cooling-only models. Condensation discharge is however required for models with a heat pump, even though its use is limited to heat pump operation. The condensation can be drawn either indoor or outside the room using the dedicated duct indoor the device’s chassis.

16 cm

Air condensed

only 26 cm

thick

45www.argoclima.com

Can also be installed on non-perimeter walls Xfetto water-condensed still eliminates the problem of the outdoor unit by housing it within its single case, but it uses water instead of air to cool the condenser. This solution has the advantage of not requiring holes in the wall and thus allows the device to be installed on any type of wall, perimeter or not.The advantages of this application include: great energy efficiency (COP up to 4.68), low power consumption (630 watts to achieve a heat output of over 3 kW) and extremely quiet operation thanks to the fact that the condenser, being water-cooled, has no ventilation system. The water-condensed version of Xfetto consumes just one cubic metre of water per day (less than one euro’s worth). Unique and special, it provides solutions for niche applications that arise much more often than you may think... From residences in historic buildings with large supplies of water, to systems with cooling towers, heat pumps and/or boilers on closed-circuit loops even when controlled by BMS, such as Lyon Airport.

Mains water useThe ideal application for areas with strict regulations governing modifications to building facades and without limitations on water use. The system nevertheless has a low level of water consumption that may reach up to one cubic metre of water per day under normal summer operating conditions, with a daily cost of less than one euro. It only requires connection to two water pipes, inflow and outflow.

Closed circuit water useXfetto can also operate as a terminal in a closed circuit water loop system with water at 30°C in accordance with EN14511 specifications. The water used to cool the condenser is fed into a circuit and drawn to a cooling tower where it is cooled and then reused by the device.

WATER / AIR COP up to 4.68

Water condensed

Mains water Recirculated waterKey

Tap

Flow rate valve

0.5 mm mechnical mesh filter

Water inlet hose

Flow switch

Solenoid

Water outlet hose

Water heat exchanger

Water inlet

Water outlet

XF

ET

TO

XF

ET

TO

A real advantage for on/off versions, both air or water-condensed, is the ability to connect Xfetto to a central heating system and use it as a radiator connected to the heating system circuit using the dedicated hydraulic module (optional), which also includes a three-way bypass valve.

To use the radiator function Xfetto must be connected to the central heating system, whether it is centralised or autonomous. Suitable checks should first be carried out on the system to determine the water flow rate conditions in terms of volume and heat output.

The connection can be made using the dedicated optional kit, which in concept represents a kind of interface module between xfetto and the central heating system. Without this kit, xfetto can still be installed with the maximum flexibility as an air conditioner/heat pump without an outdoor unit (for example in places where no central heating system is installed due to climatic conditions).

The connection kit to the central heating system is symmetrical and can be fitted on the left or right of the device. It is designed to adapt to various different existing situations (pipes on the right, pipes on the left, delivery on the right and return on the left, delivery above and return below...). This means that the same kit can be used for both sides. The size and shape of the kit elegantly covers most types of hydraulic connection.

The kit is comprised of a plastic casing and all the components (electronic and hydraulic) required for radiator operation. The installer need only make the hydraulic connections to the central heating system delivery and return pipes.

With the hydraulic module, as a radiator substitute

Installation with the hydraulic module for connection to a boiler

Radiator function!

goodbye outdoor unit...

46 www.argoclima.com

XF

ET

TO

XF

ET

TO

47www.argoclima.com

DCI SPL/HPL

SVPWM 180° full DC inverter technology

Heat pump with cool,

heat, dehumidify and fan functions

Universal multifunction remote control with LCD display,

Feel sensor, wall mount and transmitter with a wide range of

operation

Temperature check comparison between remote control

sensor and unit sensor

iFeel function

ECO and High Power functions

Horizontal deflector with 6 positions set via remote control and

iFlap function for intelligent air distribution

Automatic fan speed and/or three set speeds available via

remote control

Condensing with variable speed fan

Intelligent Cold draft and Defrost functions

Additional electrical heating (820 watts) activated by the

software in auto mode when the unit is unable to balance the

thermal load, or manually activated/deactivated via remote

control as a booster for the heat pump or as a Fan Heater

Auto-restart following black outs and excess pressure

protection devices

High efficiency rotary compressor covered by a 5-year

warranty

Optional feet for floor installation

(windows, loft conversions...)

Argo Xfetto is protected by Patent No. 261412 granted to Argoclima S.p.A. on 8th January 2009

n°dB(A)

PRODUCT NAME XFETTO DCI

stinU1,85 (1,10-2,93) 2,27 (0,90-3,05)

0,85kWA A

2,61 3,17330-300-280

1,0

43-38-35

Cooling HeatingkW

0,710 0,715355 -

230/1/50

162by duct, outside or inside the room

R410A

49735x839x260-280

3 + Auto

ABCDEFG(kW/kW)m3/hlitres/h

V/Ph/HzkW

kWh

mm

Kgmm

FeaturesCooling capacityAdditional electrical resistanceEnergy label classE.E.R. / C.O.P.Air flowrate (h.-m.-l.)DehumidificationFan speedsSound pressure (h.-m.-l.) Power supplyRunnig consumptionAnnual energy cons. - A/C (500h)-Dir. 2002/31/CERefrigerant typeDucts diameterCondensate dischargeNet weightNet dimension (H./W./D.)

XF

ET

TO

XF

ET

TO

Installation on a perimeter wall

Automatic switching from cooling to heating action based on

the set temperature (235H)

Radiator operation when connected to the heating system

circuit using the dedicated hydraulic module (optional), which

includes a three-way bypass valve

Remote control with digital 24h thermostat/timer and up to 4

addresses

Dual temperature sensor (on the unit and on the remote control)

iFeel & Night functions

Horizontal deflector that can be switched between fixed and

oscillating positions via remote control

Condensing with variable speed outdoor fan for maximum

quietness

Tangential fan with three programmable speeds or automatic

speed control

Device that prevents the release of cold air into the room by

activating heat pump mode during defrosting cycles (235H)

Device that prevents the circulation of air in the room when

the heating water temperature is below 40°C in radiator mode

Precision thermostat with settings from 6°C to 40°C in radiator

mode

Auto restart following power black outs

Electronic protection against excess pressure

High efficiency rotary compressor covered by a 5-year warranty

Optional feet for floor installation

(windows, loft conversions...)

245C cooling only

235H heat pump

Air condensed

48 www.argoclima.com

Installation on a perimeter wall

Argo Xfetto is protected by Patent No. 261412 granted to Argoclima S.p.A. on 8th January 2009

The technical data provided refers to European Standard EN14511 - Directive 2002/31/CE

PRODUCT NAME XFETTO 245C XFETTO 235H

2,45 2,35 2,25BTU/h 8.360 8.020 7.700

2.110 2.020 1.9352,10 2,10

ABCDEFG A A CE.E.R. / C.O.P. 2,62 2,61 2,65

m³/h 330-300-280 330-300-280l/h 1,2 1,0n° 3 + Auto 3 + Auto

45-43-41 45-43-4142-39-32 42-39-32230/1/50 230/1/50

0,935 0,900 0,850468 450 -

0,027 0,027R410A R410A

mm 162 1621/2" 1/2" gas F

mm - 18Kg 50 52mm 735/839/260-280 735x839x260-280

Features Units Cooling Cooling Heating

Cooling/Heating capacity (A/Conditioner mode)kW

kcal/hHeating capacity (Water Radiator mode) kWEnergy label class

(kW/kW)Air flowrate (h.-m.-l.)DehumidificationFan speedsSound pressure in Air/Conditioner mode (h.-m.-l.) dB(A)Sound pressure in Water radiator mode (h.-m.-l.) dB(A)Power supply V/Ph/HzRunning consumption in Air/Conditioner mode kWAnnual energy cons.- A/C(500h)-Directive 2002/31/EC kWhRunning consumption in Water radiator mode kWRefrigerant typeDucts diameterHydraulic connection diameter on the heating plant (W.R.mode) inchCondensate discharge not requested by duct, outside or inside the room

Condensate drain connection diameter (outside)Net weight Net dimensions (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

XF

ET

TO

XF

ET

TO

49www.argoclima.com

Can be installed on any wall, even non-perimeter walls,

because it does not require holes in the wall

Designed to work with mains water or a well/groundwater source, it

can also operate as a terminal in a closed circuit water loop system

with water at 30°C in accordance with EN14511 specifications

Very high levels of efficiency (EER up to 4.68)

Automatically switches from cooling to heating based on the

set temperature (235HP)

Operates as a radiator when connected to the heating system

circuit using the dedicated hydraulic module (optional), which

includes a three-way bypass valve

High efficiency plate heat exchanger with a solenoid to cut off

mains water circulation when the compressor is off

Antifreeze protection on condensation water circuit

Installation of a viewable filter on the mains water inlet (to be

completed by installer) recommended

Remote control with digital 24h thermostat/timer and up to 4

addresses

Dual temperature sensor (on the unit and on the remote control)

Dry, Fan Only, iFeel and Night Functions

Horizontal deflector that can be switched between fixed and

oscillating positions via remote control

Washable air filters

Tangential fan with three programmable speeds or automatic

speed control

Device that prevents the release of cold air into the room, in

heat pump mode (235HP)

Device that prevents the circulation of air in the room when

the heating water temperature is below 40°C in radiator mode

Precision thermostat with settings from 6°C to 40°C in

radiator mode

Auto restart following power black outs

Electronic protection against excess pressure

High efficiency rotary compressor covered by a 5-year

warranty

Optional feet for floor installation (windows, loft conversions...)

245SC H2O cooling only

235HP H2O heat pump

Can be installed on any wall, even non-perimeteer wallsnon-perimete

Water condensed

Argo Xfetto is protected by Patent No. 261412 granted to Argoclima S.p.A. on 8th January 2009

Mains water - Cool: Amb. temp. 27°C d.b. / 19°C w.b. - Water temp. in 18°C - out 36°C / Heat pump: Amb. temp. 20 °C d.b. - Water temp. in 18°C - out 6°C Water loop - Cool: Amb. temp. 27°C d.b. / 19°C w.b. - Water temp. in 30°C - out 35°C / Heat pump: Amb. temp. 20°C d.b. - Water temp. 15°CRadiator - Amb. temp. 20°C - Water temp. in 70°C - out 60°C

PRODUCT NAME

Water loop(*) Water loop(*)

Raffreddamento2,83 2,7 2,95 3,15 3,00 3,56

BTU/h 9.650 9.200 10.060 10.740 10.230 12.1402.430 2.320 2.540 2.710 2.580 3.060

ABCDEFG - B - - A CE.E.R. / C.O.P. 4,42 4,15 4,68 3,80 4,41 4,14

m³/h 330-300-280 330-300-280 330-300-280litri/h 1,2 1,2 1,3 1,3

n° 3 + Auto 3 + Auto 3 + Auto 3 + Auto44-42-41 44-42-41 44-42-41 44-42-41

230/1/50 230/1/500,640 0,650 0,630 0,830 0,680 0,860

- 325 - - 340 -m³/h 0,150 0,525 0,150 0,525

2,9 38,0 2,9 40,3R410A R410A R410A R410A

1/2" (gas) F 1/2" (gas) F 1/2" (gas) F 1/2" (gas) Fmm 13/18 13/18 13/18 13/18

3,47 3,35 3,58 - 3,68 -- - - 2,04 - 2,7

2,1 2,10,027 0,027

m³/h 0,19 0,192,9 2,91/2" F 1/2" (gas) F42-39-32 42-39-32

Kg 46 48mm 735/839/260-280 735x839x260-280

XFETTO 245SCH2O XFETTO 235HPH2OOperation Town water Town water

wa

ter l

oo

p:

sta

nd

ard

co

nd

itio

ns

EN

14

51

1

Features Units Raffr. Risc. Raffr. Risc.

Cooling/Heating capacity (Air-Conditioner mode)kW

kcal/hEnergy label class

(kW/kW)Air flowrate (h.-m.-l.)DehumidificationFan speedsSound pressure in Air-Conditioner mode (h.-m.-l.) dB(A)Power supply V/Ph/HzRunning consumption in Air-Conditioner mode kWAnnual energy cons.- A/C(500h)-Directive 2002/31/EC kWhWater flowrate for the heat exchanger Pressure drops KPaRefrigerant typeWater connection diameter (in/out) inchCondensate drain connection diameter (inside or outside)Heat transferred to water kWHeat moved from water kWHeating capacity in Water Radiator mode kWRunning consumption in Water radiator mode kWWater flowrate in Water Radiator modePressure drops in Water Radiator mode kPaHydraulic connection diameter to the heating plant (W.R.mode) inchSound pressure in Water radiator mode (h.-m.-l.) dB(A)Net weight Net dimensions (H./W./D.)

XF

ET

TO

XF

ET

TO

50 www.argoclima.com

Notes:

XF

ET

TO

XF

ET

TO

51www.argoclima.com

X1

X11

52 www.argoclima.com

X1

X1

Wall-mounted

split unit air conditioner and heat pump

Wall-mounted split unit with heat pump

Elegant design in PMMA (high quality material)

Environmentally-friendly refrigerant R410A

Automatic switching between cooling and heating

Equipped with a multi-function remote control with digital timer,

which allows operating cycles to be programmed over 24 hours

Tangential fan with three programmable speeds or automatic

speed control

Remote-controlled horizontal deflector: with 5 set positions or

automatic oscillation

Manually adjustable vertical deflector

Washable air filters

Activated carbon filters

BIO photocatalytic filter

Easily removable front panel secured by magnets

Automatic adaptation to night-time temperature variations

function with 4 different programmes

Dehumidify only function

Turbo function for instant coolness/warmth

Automatic restart following power black outs

Electronic compressor protection

High efficiency rotary compressor

Easy magnetic placement

X1 G 25 X1 G 35PRODUCT NAME

Indoor Unit X1 G 25HL X1 G 35HL

Outdoor Unit X1 G 25SH X1 G 35SH

Specifications Units Cooling Heating Cooling Heating

CapacitykW 2,7 2,85 3,5 3,8

BTU/h 9200 9720 12000 12960

Energy Class ABCDEFG A A A A

E.E.R. / C.O.P. (kW/kW) 3,21 3,61 3,21 3,61

Indoor unit air flow rate (h.m.l.) m³/h 450-400-320 500-450-380

Dehumidification l/h 0,8 1,2

Fan speed (Indoor / Outdoor) N° 3/1 3/1

Sound pressure Indoor (h.m.l.) dB(A) 40-37-34 40-37-34

Sound pressure Outdoor (h.) dB(A) 49 49

Power supply V/Ph/Hz 230/1/50 230/1/50

Power input kW 0,84 0,79 1,09 1,05

Annual energy consumption (500h) kWh 420 - 545 -

Compressor type Rotary Rotary

Refrigerant type R410A R410A

Liquid pipe diameter mm (inch") 6,35(1/4”) 6,35(1/4”)

Gas pipe diameter mm (inch") 9,52(3/8”) 12,7 (1/2”)

Length of pipes (with standard charge) m 7 7

Length of pipes (with additional charge) m 10 10

Maximum height difference (outdoor unit above) m 5 5

Maximum height difference (indoor unit above) m 5 5

Net dimensions Indoor (H./W./D.) mm 290x800x186 290x800x186

Net dimensions Outdoor (H./W./D.) mm 480x600x250 540x700x255

Net weight Indoor/Outdoor Kg 10/26 10/30

The technical data provided refers to European Standard EN14511 - Directive 2002/31/CE

X1 G 25 X1 G 35

53www.argoclima.com

Wall-mounted split unit with heat pump

DC Inverter technology for maximum comfort

Elegant design in PMMA (high quality material)

Environmentally-friendly refrigerant R410A

Automatic switching between cooling and heating

Equipped with a multi-function remote control with digital timer,

which allows operating cycles to be programmed over 24 hours

Tangential fan with three programmable speeds or automatic

speed control

Remote-controlled horizontal deflector: with 5 set positions or

automatic oscillation

Manually adjustable vertical deflector

Washable air filters

Activated carbon filters

BIO photocatalytic filter

Easily removable front panel secured by magnets

Automatic adaptation to night-time temperature variations function

with 4 different programmes

Dehumidify only function

Turbo function for instant coolness/warmth

Automatic restart following power black outs

Electronic compressor protection

High efficiency rotary compressor

Wall-mounted split unit

air conditioner and heat pump – DC Inverter

Easy magnetic placement

X1l G 25 X1l G 35PRODUCT NAME

Indoor Unit X1I G 25HL X1I G 35HL

Outdoor Unit X1I G 25SH X1I G 35SH

Specifications Units Cooling Heating Cooling Heating

Capacity nominal (min-max)kW 2,60 (1,45-4,0) 2,90 (1,4-5,0) 3,60 (1,84-4,10) 3,80 (1,50-5,10)

BTU/h 8.870 (4.950-13.650) 9.900 (4,8-17.100) 12.280 (6.280-14.000) 13.000 (5.120-17.400)

Energy Class ABCDEFG A A A A

E.E.R. / C.O.P. - nominal (min-max) (kW/kW) 3,42 (4,53-2,94) 3,67 (4,7-3,1) 3,43 (2,87-4,18) 3,62 (3,0-4,4)

Indoor unit air flow rate (h.m.l.) m³/h 450-400-320 500-450-380

Dehumidification l/h 0,8 1,2

Fan speed (Indoor / Outdoor) N° 3/1 3/1

Sound pressure Indoor (h.m.l.) dB(A) 38-35-32 40-37-34

Sound pressure Outdoor (h.) dB(A) 51 52

Power supply V/Ph/Hz 230/1/50 230/1/50

Power input - nominal (min-max) kW 0,76 (0,32-1,36) 0,8 (0,3-1,6) 1,050 (0,44-1,43) 1,05 (0,35-1,70)

Annual energy consumption (500h) kWh 380 - 525 -

Compressor type Rotary Rotary

Refrigerant type R410A R410A

Liquid pipe diameter mm (inch") 6,35(1/4") 6,35(1/4")

Gas pipe diameter mm (inch") 9,52(3/8") 12,7 (1/2")

Length of pipes (with standard charge) m 7 7

Length of pipes (with additional charge) m 10 10

Maximum height difference (outdoor unit above) m 5 5

Maximum height difference (indoor unit above) m 5 5

Net dimensions Indoor (H./W./D.) mm 290x800x186 290x800x186

Net dimensions Outdoor (H./W./D.) mm 540x700x255 540x700x255

Net weight Indoor/Outdoor Kg 10/26 11/30

The technical data provided refers to European Standard EN14511 - Directive 2002/31/CE

X1

X11

X1l G 25 X1l G 35

54 www.argoclima.com

Notes:

X1

X1

55www.argoclima.com

Split and package on/off, heat

pump and low ambient, up to

14 kW of thermal capacity for

mono and multi applications,

hi-wall, floor/ceiling or built-in

(cassette) types.

ON

OF

ON

OF

FF

56 www.argoclima.com

ON

OF

FO

NO

FF

Ulisse 13 PCL - 10 CLA

Floor console, cooling only

Only 24 cm depth, suitable for fixed or moveable

floor installations

Small condensing case, specifically projected to be placed

on balcony or window

Automatic condensate vaporization through the case

Infrared remote control with 24h digital timer and 4-addressing

possibility, night set back, start-up of air-conditioning or

dehumidifying or ventilation only modes, temperature digital

adjustment and room temperature control by a special sensor

indoor the remote control

Double temperature sensor (on remote control / on indoor unit)

“I Feel” feature

Dry function

Three-speed fan by remote control

Frontal air-intake, making possible its placement even between

two walls

AeroQuip quick connectors to easily disconnect and re-connect

the outdoor unit for a fixed installation

Adjustable air louver, granting the best fresh air diffusion

Washable air filters

Auto restart after a power supply black out

Electronic protection against over-pressures

High efficiency rotary compressor

Accessories for the outside fixed installation of the case supplied

with the unit

Optional pipe-extension kits connecting Indoor and Outdoor

units (2 and 4m)

OZONEFRIENDLY

R410Aeco

Cooling only

PRODUCT NAME ULISSE 10CLA ULISSE 13PCLA

2,98 4,00

BTU/h 10.160 13.640

2.560 3.440

ABCDEFG A A

E.E.R. /C.O.P. 3,22 3,21

370 400-375-335

l/h 1,2 1,9

n° 3 + Auto / 1 3 + Auto / 1

36-36-34 37-36-34

45 42

230/1/50 230/1/50

0,925 1,25

463 625

R410A R410A

m 2 2

m 2-4 2-4

m 1,2 1,2

m 5,2 5,2

Kg 44/9,5 44/15

mm 790x580x245 790x580x245

mm 435x440x230 490x525x250

Features Units Cooling Cooling

Capacity

kW

kcal/h

Energy label class

(kW/kW)

Air flowrate (h./h.-m.-l.) m

Dehumidification

Fan speeds (Indoor / Outdoor)

Sound pressure Indoor (h.m.l.) dB(A)

Sound pressure Outdoor (h.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE kWh

Refrigerant type

Standard pipe lenght

Additional pipe lenght

Max. height between units (Outdoor on the top)

Max. height between units (Indoor on the top)

Net weight Indoor / Outdoor

Net dimension Indoor (H./W./D.)

Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

57www.argoclima.com

Ulisse 10 HLA

Floor console, cooling and heat pump

Only 24 cm depth, suitable for fixed or moveable

floor installations

Small condensing case, specifically projected to be placed

on balcony or window

Infrared remote control with 24h digital timer and 4-addressing

possibility, night set back, start-up of air-conditioning

or dehumidifying or ventilation only modes, temperature digital

adjustment and room temperature control by a special

sensor indoor the remote control

Double temperature sensor (on remote control / on indoor unit)

“I Feel” feature

Dry function

Three-speed fan by remote control

Frontal air-intake, making possible its placement even

between two walls

AeroQuip quick connectors to easily disconnect and

re-connect the outdoor unit for a fixed installation

Adjustable air louver, granting the best fresh air diffusion

Washable air filters

Auto restart after a power supply black out

Electronic protection against over-pressures

High efficiency rotary compressor

Accessories for the outside fixed installation of the case

supplied with the unit

Optional pipe-extension kits connecting Indoor and Outdoor

units (2 and 4m)

OZONEFRIENDLY

R410Aeco

Heat pump

PRODUCT NAME ULISSE 10HLA

2,98 3,34

BTU/h 10.160 11.390

2.560 2.870

ABCDEFG A A

E.E.R. /C.O.P. 3,22 3,67

370

l/h 1,2

n° 3 + Auto / 1

35-31-29

39

230/1/50

0,925 0,910

463

R410A

m 2

m 2-4

m 1,2

m 5,2

Kg 44/15

mm 790x580x245

mm 490x525x250

Features Units Cooling Heating

Capacity

kW

kcal/h

Energy label class

(kW/kW)

Air flowrate (h./h.-m.-l.) m

Dehumidification

Fan speeds (Indoor / Outdoor)

Sound pressure Indoor (h.m.l.) dB(A)

Sound pressure Outdoor (h.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Annual energy consumption-cooling mode(500h)-Dir. 2002/31/CE kWh

Refrigerant type

Standard pipe lenght

Additional pipe lenght

Max. height between units (Outdoor on the top)

Max. height between units (Indoor on the top)

Net weight Indoor / Outdoor

Net dimension Indoor (H./W./D.)

Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

ON

OF

ON

OF

FF

AW 726/735 H

Automatic change-over between cooling and heating modes

Infrared remote control; 24h digital timer;

4-addressing possibility

Double temperature sensor (on the unit and indoor

the remote control)

“I Feel” feature, granting the best comfort conditions

Dry function

Three-speed tangential fan by remote control

Night set-back capability

Usable also without remote control

Horizontal flap by remote control: swinging

or six fixed positions

Vertical flap with rear protection grille, allowing a safe

installation of the indoor unit also at low distance

from the floor (min. 1,7 mt)

Washable filters; active carbon filters (optional)

Double condensate discharge (right/left)

to make easier the installation

Auto restart after a power supply black out

Electronic protection of the indoor units: anti-freeze;

heating function disabled during defrosting cycle,

electronic protection against over-pressures

High efficiency rotary compressor

Self-diagnostic functions

58 www.argoclima.com

R410Aeco

ifeel 3speed

Heat pump

PRODUCT NAME AW726H AW735H

AW726HL/F AW735HL/FAE726SH AE735SH

2,65 3,00 3,4 3,7BTU/h 9.040 10.230 11.600 12.620

2.280 2.580 2.920 3.180ABCDEFG A A A A

E.E.R. / C.O.P. 3,44 3,80 3,21 3,61450-400-370 470-430-390

l/h 1,2 - 1,5 -n° 3 + Auto/1 3 + Auto/1

41-36-32 41-36-3237 40

230/1/50 230/1/500,770 0,790 1,060 1,025

A 3,50 3,60 5,40 5,20385 - 530 -

R410A R410A6,35(1/4") 6,35(1/4")9,52(3/8") 12,7(1/2")

m 7,5 7,5m 15 15

20 20m 7 7m 7 7Kg 8/35 8/35mm 270x805x214 270x805x214mm 540x700x265 540x700x265

Indoor unitOutdoor unitFeatures Units Cooling Heating Cooling Heating

Cooling/Heating capacity kW

kcal/hEnergy label class

(kW/kW)Air flowrate Indoor (h.m.l.) m3/hDehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.m.l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzPower input kWRunning consumptionAnnual energy cons.-cooling(500h)-Dir. 2002/31/CE kWhCompressor type Rotary RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeGas additional charge gr/mMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

ON

OF

FO

NO

FF

59www.argoclima.com

AW 752/764H/764H3

Automatic change-over between cooling and heating modes

Available in single-phase and three-phase versions (764H3)

Infrared remote control; 24h digital timer;

4-addressing possibility

Double temperature sensor (on the unit and indoor the

remote control)

“I Feel” feature, granting the best comfort conditions

Dry function

Three-speed tangential fan by remote control

Night set back capability

Usable also without remote control

Horizontal flap by remote control: swinging or six fixed positions

Vertical flap with rear protection grille, allowing a safe installation

of the indoor unit also at low distance from the floor

(min. 1,7 mt)

Washable air filters; active carbon filters (optional)

Double condensate discharge (right/left) to make easier

the installation

Auto restart after a power supply black out

Electronic protection of the indoor units: anti-freeze;

heating function disabled during defrosting cycle,

electronic protection against over-pressures

Anti-freeze protection of the outdoor unit

High efficiency rotary compressor

Self-diagnostic functions

Single-phase and three-phase (764H3) power supply

R410Aeco

ifeel 3speed

Heat pump

PRODUCT NAME AW752H AW764H AW764H3

AW752HL AW764HL AW764HLAE752SH AE764SH AE764SH3

5,00 5,80 6,60 7,80 6,80 8,00BTU/h 17.100 19.780 22.500 26.600 23.200 27.280

4.300 4.990 5.676 6.710 5.848 6.880ABCDEFG A A A A A A

E.E.R. / C.O.P. 3,23 3,82 3,22 3,63 3,24 3,64880-710-580 880-710-580 880-710-580

l/h 1,5 - 2,0 - 2,0 -n° 3 + Auto/1 3 + Auto/1 3 + Auto/1

46-43-38 49-43-38 49-43-3843 47 47

230/1/50 230/1/50 400/3N/501,55 1,52 2,05 2,15 2,10 2,20

A 7,00 6,70 9,20 9,50 4,10 4,30775 - 1025 - 1050 -

R410A R410A R410A6,35(1/4") 6,35(1/4") 6,35(1/4")12,7(1/2") 15,88(5/8") 15,88(5/8")

m 10 12,5 12,5m 20 30 30

20 25 25m 15 15 15m 15 15 15Kg 12/57 12/71 12/71mm 285x995x240 285x995x240 285x995x240mm 630x830x305 735x940x340 735x940x340

Indoor unitOutdoor unitFeatures Units Cooling Heating Cooling Heating Cooling Heating

Cooling/Heating capacity kW

kcal/hEnergy label class

(kW/kW)Air flowrate Indoor (h.m.l.) m3/hDehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.m.l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzPower input kWRunning consumptionAnnual energy cons.-cooling(500h)-Dir. 2002/31/CE kWhCompressor type Rotary Rotary RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeGas additional charge gr/mMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

ON

OF

ON

OF

FF

AW 726/735 CL

Able to operate with an outdoor air temperature up to -15°C

Infrared remote control; 24h digital timer; 4-addressing possibility

Double temperature sensor (on the unit and indoor the remote

control)

“I Feel” feature, granting the best comfort conditions

Dry function

Three-speed tangential fan by remote control

Night set-back capability

Usable also without remote control

Horizontal flap by remote control: swinging or six fixed positions

Vertical flap with rear protection grille, allowing safe installations

of the indoor unit even at any height from the floor

(min. 1,7 m.) (EN60335 safety standard)

Washable filters; active carbon filters (optional)

Double condensate discharge (right/left)

to make easier the installation

Auto restart after a power supply black out

Electronic protection against over-pressures

High efficiency rotary compressor

Self-diagnostic functions

60 www.argoclima.com

R410Aeco

ifeel

3speed

+43°C

-15°C

active carbonfilter

OZONEFRIENDLY

washablefilters

Cooling only

MATCHING AW726CL AW735CL

AW726CL/F AW735CL/FAE726SCL AE735SCL

2,70 3,40ABCDEFG A A

E.E.R. 3,51 3,24450-400-370 470-430-390

l/h 0,8 1,5n° 3 + Auto/1 3 + Auto/1

41-36-32 41-36-3237 40

230/1/50 230/1/500,770 1,050

A 3,40 4,70385 525

R410A R410A6,35(1/4") 6,35(1/4")9,52(3/8") 12,7(1/2")

m 7,5 7,5m 15 15

20 20m 7 7m 7 7Kg 8/34 8/34mm 270x805x214 270x805x214mm 540x700x265 540x700x265

Indoor unitOutdoor unitFeatures Units Cooling CoolingCooling capacity kWEnergy label class

(kW/kW)Air flowrate Indoor (h.-m.-l.) m3/hDehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.-m.-l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzPower input kWRunning consumptionAnnual energy cons.- cooling (500h) - Dir.2002/31/CE kWhCompressor type Rotary RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeGas additional charge gr/mMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

ON

OF

FO

NO

FF

61www.argoclima.com

AW 752 CL/CL3 -AW 764 CL3

Able to operate with an outdoor air temperature up to -15°C

Infrared remote control; 24h digital timer;

4-addressing possibility

Double temperature sensor (on the unit and indoor

the remote control)

“I Feel” feature, granting the best comfort conditions

Dry function

Three-speed tangential fan by remote control

Night set-back capability

Usable also without remote control

Horizontal flap by remote control: swinging or six fixed positions

Vertical flap with rear protection grille, allowing safe installations

of the indoor unit even at any height from the floor

(min. 1,7 m.) (EN60335 safety standard)

Washable filters; active carbon filters (optional)

Double condensate discharge (right/left) to make

easier the installation

Auto restart after a power supply black out

Electronic protection against over-pressures

High efficiency rotary compressor

Self-diagnostic functions

Single-phase and three-phase versions

R410Aeco

ifeel

3speed

+43°C

-15°C

active carbonfilter

OZONEFRIENDLY

washablefilters

Cooling only

ON

OF

ON

OF

FF

FC 735/752 CL

Able to operate with an outdoor air temperature up to -15°C

Single-phase (230V-1-50Hz) power supply

Infrared remote control; 24h digital timer;

4-addressing possibility

Double temperature sensor (on the unit and indoor

the remote control)

“I Feel” feature, granting the best comfort conditions

Dry function

Three-speed centrifugal fan by remote control

Night set-back capability

Usable also without remote control

Horizontal flap swinging or to be set to on of the six

possible fixed position by remote control

Vertical flap by manual control

Washable filters; active carbon filters (optional)

Auto restart after a power supply black out

Electronic protection against over-pressures

High efficiency rotary compressor

Self-diagnostic functions

62 www.argoclima.com

R410Aeco

ifeel

3speed

+43°C

-15°C

active carbonfilter

OZONEFRIENDLY

washablefilters

Cooling only

PRODUCT NAME FC735CL FC752CL

FC735CL FC752CLAE735SCL AE752SCL

3,40 5,00ABCDEFG A A

E.E.R. 3,24 3,23670-550-450 715-610-510

l/h 1,5 1,8n° 3 + Auto/1 3 + Auto/1

47-44-39 49-47-4040 43

230/1/50 230/1/501,05 1,55

A 4,70 7,00525 775

R410A R410A6,35(1/4") 6,35(1/4")12,7(1/2") 12,7(1/2")

m 7,5 10m 15 20

20 20m 7 15m 7 15Kg 23,5/34 23,5/55mm 680x900x190 680x900x190mm 540x700x265 630x830x305

Indoor unitOutdoor unitFeatures Units Cooling CoolingCooling capacity kWEnergy label class

(kW/kW)Air flowrate Indoor (h.-m.-l.) m3/hDehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.-m.-l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzPower input kWRunning consumptionAnnual energy cons.-cooling(500h)-Dir. 2002/31/CE kWhCompressor type Rotary RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeGas additional charge gr/mMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

ON

OF

FO

NO

FF

63www.argoclima.com

FC 752/764 CL3

Able to operate with an outdoor air temperature up to -15°C

Three-phase (400-3N-50Hz) power supply

Infrared remote control; 24h digital timer;

4-addressing possibility

Double temperature sensor (on the unit and indoor

the remote control)

“I Feel” feature, granting the best comfort conditions

Dry function

Three-speed centrifugal fan by remote control

Night set-back capability

Usable also without remote cotrol

Horizontal flap swinging or to be set to on of the six possible

fixed position by remote control

Vertical flap by manual control

Washable filters; active carbon filters (optional)

Auto restart after a power supply black out

Electronic protection against over-pressures

High efficiency rotary compressor

Self-diagnostic functions

R410Aeco

ifeel

3speed

+43°C

-15°C

active carbonfilter

OZONEFRIENDLY

washablefilters

Cooling only

PRODUCT NAME FC752CL3 FC764CL3

FC752CL FC764CL

AE752SCL3 AE764SCL3

5,00 6,50

ABCDEFG A B

E.E.R. 3,23 3,13

715-610-510 890-790-640

l/h 1,8 2,0

n° 3 + Auto/1 3 + Auto/1

49-47-40 51-49-46

44 47

400/3N/50 400/3N/50

1,55 2,08

A 3,20 4,20

775 1040

R410A R410A

6,35(1/4") 6,35(1/4")

12,7(1/2") 15,88(5/8")

m 10 12,5

m 20 30

20 25

m 15 15

m 15 15

Kg 23,5/55 23,5/71

mm 680x900x190 680x900x190

mm 630x830x305 735x940x340

Indoor unit

Outdoor unit

Features Units Cooling Cooling

Cooling capacity kW

Energy label class

(kW/kW)

Air flowrate Indoor (h.-m.-l.) m3/hDehumidification

Fan speeds (Indoor / Outdoor)

Sound pressure Indoor (h.-m.-l.) dB(A)

Sound pressure Outdoor (h.) dB(A)

Power supply V/Ph/Hz

Power input kW

Running consumption

Annual energy cons.-cooling(500h)-Dir. 2002/31/CE kWh

Compressor type Rotary Rotary

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Max. pipe lenght with gas standard charge

Max. pipe lenght with gas additional charge

Gas additional charge gr/m

Max. height between units (Outdoor on top)

Max. height between units (Indoor on top)

Net weight Indoor / Outdoor

Net dimension Indoor (H./W./D.)

Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

ON

OF

ON

OF

FF

AS 71/100/125 CL3

Able to run with an outdoor air temperature up to -15°C

Three-phase (400-3-50 Hz) power supply

Infrared remote control; 24h digital timer;

4-addressing possibility

Double temperature sensor (on the unit and indoor

the remote control)

“I Feel” feature, granting the best comfort conditions

Dry function

Three-speed centrifugal fan by remote control

Special system to avoid condensate dripping from air outlet ribs

Night set-back capability

Usable also without remote cotrol

Four horizontal flap by remote control: swinging

or six fixed positions

Washable filters

Integrated pump for condensate discharge

Auto restart after a power supply black-out

Electronic protection against over-pressures

High efficiency rotary compressor

Self-diagnostic functions

64 www.argoclima.com

R410Aeco

ifeel

3speed

+43°C

-15°C

active carbonfilter

OZONEFRIENDLY

washablefilters

Cooling only

PRODUCT NAME AS71CL3 AS100CL3 AS125CL3

AS71CL AS100CL AS125CLAE71SCL3 AE100SCL3 AE125SCL3

7,80 10,40 14,10ABCDEFG B A

E.E.R. / C.O.P. 3,02 3,21 2,82680-840-1.020 1.320-1.680-1.920 1.320-1.680-1.920

l/h 3,0 3,5 5,0n° 3 + Auto/ 2-3 (Auto) 3 + Auto/ 2-3 (Auto) 3 + Auto/ 2-3 (Auto)

47-45-44 54-51-47 54-51-4748 50 51

400/3N/50 400/3N/50 400/3N/502,58 3,30 5,00

A 5,10 6,60 9,701290 1.650

R410A R410A R410A6,35(1/4") 9,52(3/8") 9,52(3/8")15,88(5/8") 19,05(3/4") 19,05(3/4")

m 7,5 7,5 7,5m 30 40 40m 15 25 25m 15 25 25Kg 22/71 27/104 27/128mm 338x860x860 368x1.150x860 368x1.150x860mm 735x940x340 1.235x940x340 1.235x940x340

Indoor unitOutdoor unitFeatures Units Cooling Cooling Cooling Cooling/Heating capacity kWEnergy label class not under Energy labelling

(kW/kW)Air flowrate Indoor (l.-m.-h.) m3/hDehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.-m.-l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzPower input kWRunning consumptionAnnual energy cons.- cooling (500h)-Dir. 2002/31/CE kWh not under Energy labelling

Compressor type Rotary Rotary ScrollRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor (with grille) / OutdoorNet dimension Indoor (with grille) (H./W./D.)Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

ON

OF

FO

NO

FF

65www.argoclima.com

Notes:

ON

OF

ON

OF

FF

66 www.argoclima.com

Notes:

ON

OF

FO

NO

FF

67www.argoclima.com

PAAAA

CCK

AAGG

PAAA

CK

AAG

EE

Package DC Inverter up to 14 kW of

thermal capacity for single and multi

applications, for high-wall, floor/ceiling

or built-in type (cassette and ducted)

AWS 71 PH/H3

PAM DC Inverter technology

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting

cycle to avoid cool air emission in the room

Among controls available for this kind of indoor unit (all optional):

the infrared remote control, equipped with a 24h digital timer

and a temperature sensor granting automatically the best

comfort conditions (“I Feel” feature); a special wired controller

with configuration, diagnostic and weekly timer capabilities

Night set back capability

Dry function

New three-speed tangential fan by remote control, granting a

better and low noise air diffusion

Horizontal flap swinging or to be set to a fixed position

by remote control

Vertical flap by manual control

Washable air filters

Dynamic refrigerant control by DC Inverter compressor and

circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

Auto restart after a power supply black out

Electronic protection against over-pressures

Wide operating range with outdoor air temperatures

up to -15°C in both cooling and heating modes

Single-phase (230/1/50) and Three-phase (400/3/50)

power supply

High efficiency Twin rotary compressor

68 www.argoclima.com

PA

CK

AG

EP

AC

KA

GE

R410Aeco

ifeel 3speed+43°C

-15°C

auto restart

washablefilters

PRODUCT NAME AWS71PH/H3/H3B

AWS71PHAES71PIH/H3/H3B

7,10 (2,2-8,0) 8,00 (2,2-9,0)BTU/h 24.000 27.000

6.100 6.880ABCDEFG B B

E.E.R. / C.O.P. 3,01 3,54m³/h 1.140-1.020-840l/h 4,0n° 3 + Auto / 3 (Auto)

41-37-3449

230/1/50-400/3/502,36 2,261.180 -

R410A9,52(3/8")15,88(5/8")

m 30m 50

40m 50m 30Kg 21/58mm 330x1.140x228mm 780x940x340

Indoor unitOutdoor unitFeatures Units Cooling Heating

Cooling/Heating capacity - nominal (min-max)kW

kcal/hEnergy label class

(kW/kW)Air flowrate Indoor (h.m.l.)DehumidificationFan speeds (Indoor / Outdoor)Sound pressure Indoor (h.m.l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply V/Ph/HzRunning consumption kWAnnual energy cons.- cooling mode (500h) - Directive 2002/31/CE kWhCompressor type DCInverter Twin RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeGas additional charge gr/mMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

69www.argoclima.com

ASS 71/100 PH/H3

PAM DC Inverter technology

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting

cycle to avoid cool air emission in the room

Among controls available for this kind of indoor unit

(all optional): the infrared remote control, equipped with

a 24h digital timer and a temperature sensor granting

automatically the best comfort conditions (“I Feel” feature);

a special wired controller with configuration, diagnostic and

weekly timer capabilities

Night set back capability

Dry function

New three-speed centrifugal fan by remote control, granting

a better and low noise air diffusion

Special system to avoid condensate dripping from air

outlet ribs

Four horizontal flaps swinging or to be set on a fixed

position by remote control

Washable filters

Integrated pump for condensate discharge

Dynamic refrigerant control by DC Inverter compressor

and circuit, electronic

Valve and fuzzy logic managed by a powerful

microprocessor

Auto restart after a power supply black out

Electronic protection against over-pressures

Wide operating range with outdoor air temperatures up

to -15°C in both cooling and heating modes

Single-phase (230/1/50) and three-phase (400/3/50)

power supply

High efficiency Twin rotary compressor

R410Aeco

ifeel 3speed+43°C

-15°C

auto restart

washablefilters

PRODUCT NAME ASS71PH/H3/H3B ASS100PH/H3/H3B

ASS71PH ASS100PHAES71PIH/H3/H3B AES100PIH/H3/H3B

7,10 (2,2-8,0) 8,00 (2,2-9,0) 10,00 (2,2-11,2) 11,20 (2,2-12,50)BTU/h 24.000 27.000 34.000 38.000

6.100 6.880 8.600 9.630ABCDEFG A A A A

E.E.R. / C.O.P. 3,33 3,86 3,21 3,78m³/h 1.140-1.020-840 1.920-1.680-1.320l/h 3,6 4,6n°

47-45-41 53-50-4647 49 51 52

230/1/50 - 400/3/50 230/1/50 - 400/3/502,13 2,07 3,12 2,961.065 - 1.560 -

R410A R410A9,52(3/8") 9,52(3/8")15,88(5/8") 15,88(5/8")

m 30 30m 50 50m 30 30m 15 15Kg 28/58 35/65mm 338x860x860 338x1.150x860mm 780x940x340 780x940x340

Indoor unitOutdoor unit (1ph/3ph)Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity - nominal (min-max)kW

kcal/hEnergy label class

(kW/kW)Air flowrate Indoor (h.m.l.)DehumidificationFan speeds (Indoor / Outdoor) 3 + Auto / variable 3 + Auto / variableSound pressure Indoor (h.m.l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply (1ph-3ph) V/Ph/HzRunning consumption kWAnnual energy cons.- cooling mode (500h) - Directive 2002/31/CE kWhCompressor type DCInverter Twin Rotary DCInverter Twin RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

PA

CK

AG

PA

CK

AG

EE

ASS 125 PH/H3B

PAM DC Inverter technology

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting

cycle to avoid cool air emission in the room

Among controls available for this kind of indoor unit

(all optional): the infrared remote control, equipped with a 24h

digital timer and a temperature sensor granting automatically

the best comfort conditions (“I Feel” feature); a special wired

controller with configuration, diagnostic and weekly timer

capabilities

Night set back capability

Dry function

New three-speed centrifugal fan by remote control, granting a

better and low noise air diffusion

Special system to avoid condensate dripping from air

outlet ribs

Four horizontal flaps swinging or to be set on a fixed position

by remote control

Washable filters

Integrated pump for condensate discharge

Dynamic refrigerant control by DC Inverter compressor and

circuit, electronic

Valve and fuzzy logic managed by a powerful microprocessor

Auto restart after a power supply black out

Electronic protection against over-pressures

Wide operating range with outdoor air temperatures

up to -15°C in both cooling and heating modes

Single-phase (230/1/50) and three-phase (400/3/50)

power supply

High efficiency Twin rotary compressor

70 www.argoclima.com

R410Aeco

ifeel 3speed+43°C

-15°C

auto restart

washablefilters

PRODUCT NAME ASS125PH/H3B

ASS125PH

AES125PIH/H3B

12,50 (2,7-14,0) 14,00 (2,7-16,00)

BTU/h 42.500 48.000

10.750 12.040

--

--

GFEDCBA

E.E.R. / C.O.P. 2,81 3,32

023.1-086.1-029.1h/³m

3,6h/l

53-50-46

52/51 53/54

230/1/50 / 400/3/50

3,86/4,45 3,83/4,22

R410A

9,52(3/8")

15,88(5/8")

03m

05m

03m

51m

001/53gK

068x051.1x833mm

0 / 910x940x34043x049x032.1mm

Indoor unit

Outdoor unit (1ph/3ph)

Features Units Cooling Heating

Cooling/Heating capacity - nominal (min-max)

kW

kcal/h

Energy label class

(kW/kW)

Air flowrate Indoor (h.m.l.)

Dehumidification

Fan speeds (Indoor / Outdoor) 3 + Auto / variable

)A(Bd).l.m.h( roodnI erusserp dnuoS

)A(Bd).h( roodtuO erusserp dnuoS

zH/hP/V)hp3-hp1( ylppus rewoP

Running consumption kW

hWk EC/13/2002 evitceriD - )h005( edom gnilooc -.snoc ygrene launnA

Compressor type DCInverter Twin Rotary

Refrigerant type

)"hcni(mmretemaid epip diuqiL

Gas pipe diameter mm(inch")

Max. pipe lenght with gas standard charge

Max. pipe lenght with gas additional charge

Max. height between units (Outdoor on top)

Max. height between units (Indoor on top)

Net weight Indoor / Outdoor

Net dimension Indoor (H./W./D.)

Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

PA

CK

AG

EP

AC

KA

GE

71www.argoclima.com

ADS 71 PH/H3

PAM DC Inverter technology

Three-way duct connection

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting

cycle to avoid cool air emission in the room

Among controls available for this kind of indoor unit

(all optional): the infrared remote control, equipped with

a 24h digital timer and a temperature sensor granting

automatically the best comfort conditions (“I Feel” feature);

a special wired controller with configuration, diagnostic

and weekly timer capabilities

Night set back capability

Dry function

Possibility to increase the Static Pressure

New centrifugal fan, with double static pressure, three speeds

by remote control, granting a better and low noise air diffusion

Integrated pump for condensate discharge

Dynamic refrigerant control by DC Inverter compressor and

circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

Auto restart after a power supply black out

Electronic protection against over-pressures

Wide operating range with outdoor air temperatures

up to -15°C in both cooling and heating modes

Single (230/1/50) and three-phase (400/3/50) power supply

High efficiency Twin rotary compressor

R410Aeco

ifeel 3speed+43°C

-15°C

auto restart

integratedplenum

PRODUCT NAME ADS71PH/H3/H3B

ADS71PHAES71PIH/H3/H3B

7,10 (2,2-8,0) 8,00 (2,2-9,0)BTU/h 24.000 27.000

6.100 6.880ABCDEFG C C

E.E.R. / C.O.P. 2,83 3,351.080-900-780

l/h 3,5mm W.C. 5-10

n°43-39-3634-30-27

47 49230/1/50 - 400/3/50

2,51 2,391.255 -

R410A9,52(3/8")15,88(5/8")

m 30m 50m 30m 15mm 200Kg 32/58mm 310x1.000x630mm 780x940x340

Indoor unitOutdoor unit (1ph/3ph)Features Units Cooling Heating

Cooling/Heating capacity - nominal (min-max)kW

kcal/hEnergy label class

(kW/kW)Air flowrate (h.m.l.) mDehumidificationExternal static pressure (min-max)Fan speeds (Indoor / Outdoor) 3 + Auto / variableSound power Indoor (h.m.l.) dB(A)Sound pressure Indoor (h.m.l.) dB(A)Sound pressure Indoor at ducts exit dB(A) 20Sound pressure Outdoor (h.) dB(A)Power supply (1ph-3ph) V/Ph/HzRunning consumption - nominal (min-max) kWAnnual energy cons.- cooling mode (500h) - Directive 2002/31/CE kWhCompressor type DCInverter Twin RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Ducts diameter Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

PA

CK

AG

PA

CK

AG

EE

ADS 100 PH/H3

PAM DC Inverter technology

Four-way duct connection

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting

cycle to avoid cool air emission in the room

Among controls available for this kind of indoor unit (all optional):

the infrared remote control, equipped with a 24h digital timer

and a temperature sensor granting automatically the best

comfort conditions (“I Feel” feature); a special wired controller

with configuration, diagnostic and weekly timer capabilities

Night set back capability

Dry function

Possibility to increase the Static Pressure

Integrated pump for condensate discharge

New centrifugal fan, with double static pressure, three speeds

by remote control, granting a better and low noise air diffusion

Dynamic refrigerant control by DC Inverter compressor

and circuit, electronic valve and fuzzy logic managed

by a powerful microprocessor

Auto restart after a power supply black out

Electronic protection against over-pressures

Wide operating range with outdoor air temperatures up to

-15°C in both cooling and heating modes

Single (230/1/50) and three-phase (400/3/50) power supply

High efficiency Twin rotary compressor

72 www.argoclima.com

R410Aeco

ifeel 3speed+43°C

-15°C

auto restart

integratedplenum

PRODUCT NAME ADS100PH/H3/H3B

ADS100PHAES100PIH/H3/H3B

10,00 (2,2-11,2) 11,20 (2,2-12,50)BTU/h 34.000 38.000

8.600 9.630ABCDEFG C C

E.E.R. / C.O.P. 2,82 3,391.800-1.560-1.260

l/h 4,2mm W.C. 5-10

n°47-42-4038-33-31

51 52230/1/50

3,55 3,301.775 -

R410A9,52(3/8")15,88(5/8")

m 30m 50m 30m 15mm 200Kg 47/65mm 310x1.480x630mm 780x940x340

Indoor unitOutdoor unit (1ph/3ph)Features Units Cooling Heating

Cooling/Heating capacity - nominal (min-max)kW

kcal/hEnergy label class

(kW/kW)Air flowrate (h.m.l.) mDehumidificationExternal static pressure (min-max)Fan speeds (Indoor / Outdoor) 3 + Auto / variableSound power Indoor (h.m.l.) dB(A)Sound pressure Indoor (h.m.l.) dB(A)Sound pressure Indoor at ducts exit dB(A) 20Sound pressure Outdoor (h.) dB(A)Power supply (1ph-3ph) V/Ph/HzRunning consumption - nominal (min-max) kWAnnual energy cons.- cooling mode (500h) - Directive 2002/31/CE kWhCompressor type DCInverter Twin RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Ducts diameter Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

PA

CK

AG

EP

AC

KA

GE

73www.argoclima.com

ADS 125 PH/H3B

PAM DC Inverter technology

Four-way duct connection

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting

cycle to avoid cool air emission in the room

Among controls available for this kind of indoor unit (all optional):

the infrared remote control, equipped with a 24h digital timer

and a temperature sensor granting automatically the best

comfort conditions (“I Feel” feature); a special wired controller

with configuration, diagnostic and weekly timer capabilities

Night set back capability

Dry function

Possibility to increase the Static Pressure

Integrated pump for condensate discharge

New centrifugal fan, with double static pressure, three speeds

by remote control, granting a better and low noise air diffusion

Dynamic refrigerant control by DC Inverter compressor and

circuit, electronic valve and fuzzy logic managed by

a powerful microprocessor

Auto restart after a power supply black out

Electronic protection against over-pressures

Wide operating range with outdoor air temperatures up to

-15°C in both cooling and heating modes

Single (230/1/50) and three-phase (400/3/50) power supply

High efficiency Twin rotary compressor

R410Aeco

ifeel 3speed+43°C

-15°C

auto restart

integratedplenum

PRODUCT NAME ADS125PH/H3B

ADS125PH

AES125PIH/H3B

12,50 (2,7-14,0) 14,00 (2,7-16,00)

BTU/h 42.500 48.000

10.750 12.040

--GFEDCBA

E.E.R. / C.O.P. 2,87/2,43 3,26/2,81

1.980-1.560-1.320

6,6h/l

01-5.C.W mm

49-46-42

40-37-33

52/51

4,36/5,14 4,29/4,85

53/54

230/1/50 / 400/3/50

2.180/2.570

R410A

9,52(3/8")

15,88(5/8")

03m

05m

03m

51m

002 mm

0/7601-74gK

036x084.1x013mm

0 / 910x940x34043x049x032.1mm

Indoor unit

Outdoor unit (1ph/3ph)

Features Units Cooling Heating

Cooling/Heating capacity - nominal (min-max)

kW

kcal/h

Energy label class

(kW/kW)

Air flowrate (h.m.l.) m3/h

Dehumidification

External static pressure (min-max)

Fan speeds (Indoor / Outdoor) 3 + Auto / variable

)A(Bd).l.m.h( roodnI rewop dnuoS

)A(Bd).l.m.h( roodnI erusserp dnuoS

)A(Bdtixe stcud ta roodnI erusserp dnuoS <20

)A(Bd).h( roodtuO erusserp dnuoS

zH/hP/V)hp3-hp1( ylppus rewoP

Wk)xam-nim( lanimon - noitpmusnoc gninnuR

hWk EC/13/2002 evitceriD - )h005( edom gnilooc -.snoc ygrene launnA

Compressor type DCInverter Twin Rotary

Refrigerant type

)"hcni(mmretemaid epip diuqiL

Gas pipe diameter mm(inch")

Max. pipe lenght with gas standard charge

Max. pipe lenght with gas additional charge

Max. height between units (Outdoor on top)

Max. height between units (Indoor on top)

Ducts diameter

Net weight Indoor / Outdoor

Net dimension Indoor (H./W./D.)

Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

PA

CK

AG

PA

CK

AG

EE

ACS 71/100 PH/H3

PAM DC Inverter technology

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting

cycle to avoid cool air emission in the room

Among controls available for this kind of indoor unit

(all optional): the infrared remote control, equipped with

a 24h digital timer and a temperature sensor granting

automatically the best comfort conditions (“I Feel” feature);

a special wired controller with configuration, diagnostic

and weekly timer capabilities

Night set back capability

Dry function

Three-speed centrifugal fan by remote control, granting a better

and low noise air diffusion

Horizontal flap swinging or to be set on a fixed position

by remote control, with automatic positioning according

to selected mode (cooling or heating)

Washable air filters

Dynamic refrigerant control by DC Inverter compressor and

circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

Auto restart after a power supply black out

Electronic protection against over-pressures

Wide operating range with outdoor air temperatures up to

-15°C in both cooling and heating modes

Single-phase (230/1/50) and three-phase (400/3/50)

power supply

High efficiency Twin rotary compressor

74 www.argoclima.com

R410Aeco

ifeel 3speed+43°C

-15°C

auto restart

washablefilters

PRODUCT NAME ACS71PH/H3/H3B ACS100PH/H3/H3B

ACS71PH ACS100PHAES71PIH/H3/H3B AES100PIH/H3/H3B

7,10 (2,2-8,0) 8,00 (2,2-9,0) 10,00 (2,2-11,2) 11,20 (2,2-12,50)BTU/h 24.000 27.000 34.000 38.000

6.100 6.880 8.600 9.630ABCDEFG B B B A

E.E.R. / C.O.P. 3,02 3,56 3,04 3,67m³/h 1.098-900-840 1.650-1.380-1.200l/h 3,0 3,9n°

38-36-33 41-38-3547 49 51 52

230/1/50 - 400/3/50 230/1/50 - 400/3/502,35 2,25 3,29 3,671.175 - 1.645 -

R410A R410A9,52(3/8") 9,52(3/8")15,88(5/8") 15,88(5/8")

m 30 30m 50 50m 30 30m 15 15Kg 25/58 33/65mm 210x1.180x680 210x1.595x680mm 780x940x340 780x940x340

Indoor unitOutdoor unit (1ph/3ph)Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity - nominal (min-max)kW

kcal/hEnergy label class

(kW/kW)Air flowrate Indoor (h.m.l.)DehumidificationFan speeds (Indoor / Outdoor) 3 + Auto / variable 3 + Auto / variableSound pressure Indoor (h.m.l.) dB(A)Sound pressure Outdoor (h.) dB(A)Power supply (1ph-3ph) V/Ph/HzRunning consumption kWAnnual energy cons.- cooling mode (500h) - Directive 2002/31/CE kWhCompressor type DCInverter Twin Rotary DCInverter Twin RotaryRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. pipe lenght with gas standard chargeMax. pipe lenght with gas additional chargeMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight Indoor / OutdoorNet dimension Indoor (H./W./D.)Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

PA

CK

AG

EP

AC

KA

GE

75www.argoclima.com

ACS 125 PH/H3

PAM DC Inverter technology

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting

cycle to avoid cool air emission in the room

Among controls available for this kind of indoor unit

(all optional): the infrared remote control, equipped with

a 24h digital timer and a temperature sensor granting

automatically the best comfort conditions (“I Feel” feature);

a special wired controller with configuration, diagnostic

and weekly timer capabilities

Night set back capability

Dry function

Three-speed centrifugal fan by remote control, granting

a better and low noise air diffusion

Horizontal flap swinging or to be set on a fixed position

by remote control, with automatic positioning according

to selected mode (cooling or heating)

Washable air filters

Dynamic refrigerant control by DC Inverter compressor

and circuit, electronic valve and fuzzy logic managed

by a powerful microprocessor

Auto restart after a power supply black out

Electronic protection against over-pressures

Wide operating range with outdoor air temperatures up to

-15°C in both cooling and heating modes

Single-phase (230/1/50) and three-phase (400/3/50)

power supply

High efficiency Twin rotary compressor

R410Aeco

ifeel 3speed+43°C

-15°C

auto restart

washablefilters

PRODUCT NAME ACS125PH/H3B

ACS125PH

AES125PIH/AES125PIH3B

12,50 (2,7-14,0) 14,00 (2,7-16,00)

BTU/h 42.500 48.000

10.750 12.040

--GFEDCBA

E.E.R. / C.O.P. 3,03/2,36 3,44/3,15

023.1-065.1-008.1h/³m

6,5h/l

43-40-37

52/51 53/54

230/1/50 / 400/3/50

4,12/5,29 4,07/4,45

2.060/2645 -

R410A

9,52(3/8")

15,88(5/8")

03m

05m

03m

51m

001/33gK

086x595.1x012mm

0 / 910X940X34043x049x032.1mm

Indoor unit

Outdoor unit (1ph/3ph)

Features Units Cooling Heating

Cooling/Heating capacity - nominal (min-max)

kW

kcal/h

Energy label class

(kW/kW)

Air flowrate Indoor (h.m.l.)

Dehumidification

Fan speeds (Indoor / Outdoor) 3 + Auto / variable

)A(Bd).l.m.h( roodnI erusserp dnuoS

)A(Bd).h( roodtuO erusserp dnuoS

zH/hP/V)hp3-hp1( ylppus rewoP

Running consumption kW

hWk EC/13/2002 evitceriD - )h005( edom gnilooc -.snoc ygrene launnA

Compressor type DCInverter Twin Rotary

Refrigerant type

)"hcni(mmretemaid epip diuqiL

Gas pipe diameter mm(inch")

Max. pipe lenght with gas standard charge

Max. pipe lenght with gas additional charge

Max. height between units (Outdoor on top)

Max. height between units (Indoor on top)

Net weight Indoor / Outdoor

Net dimension Indoor (H./W./D.)

Net dimension Outdoor (H./W./D.)

The technical data here indicated are in compliance with the European standard EN14511 - Directive 2002/31/EC

PA

CK

AG

PA

CK

AG

EE

Multipackage DC Inverter

AES 125 PIH/H3Cooling: 12,5 kWHeating: 14 kW

AES 71 PIH/H3(B)Cooling: 7,1 kWHeating: 8 kW

AES 100 PIH/H3(B)Cooling: 10 kWHeating: 11,2 kW

AES 125 PIH/H3BCooling: 12,5 kWHeating: 14 kW

76 www.argoclima.com

OUTDOOR UNIT MODEL AES71PIH/H3/H3B

A B C D A B C D

AWS71PH 7,10 - - - 7,1 (2,2-8,0) 8,00 - - - 8,0 (2,2-9,0)

ASS71PH Cassette 7,10 - - - 7,1 (2,2-8,0) 8,00 - - - 8,0 (2,2-9,0)

ACS71PH 7,10 7,1 (2,2-8,0) 8,00 8,0 (2,2-9,0)

ADS71PH 7,10 - - - 7,1 (2,2-8,0) 8,00 - - - 8,0 (2,2-9,0)AWS36PH 3,55 3,55 - - 7,1 (2,2-8,0) 4,00 4,00 - - 8,0 (2,2-9,0)ASS36PH Cassette 3,55 3,55 - - 7,1 (2,2-8,0) 4,00 4,00 - - 8,0 (2,2-9,0)

ADS36PH 3,55 3,55 - - 7,1 (2,2-8,0) 4,00 4,00 - - 8,0 (2,2-9,0)

FC36PHG 3,55 3,55 - - 7,1 (2,2-8,0) 4,00 4,00 - - 8,0 (2,2-9,0)

OUTDOOR UNIT MODEL AES100PIH/H3/H3B

A B C D A B C D

ASS100PH Cassette 10,00 - - - 10,0 (2,2-11,2) 11,20 - - - 11,2 (2,2-12,5)

ACS100PH 10,00 - - - 10,0 (2,2-11,2) 11,20 - - - 11,2 (2,2-12,5)

ADS100PH 10,00 - - - 10,0 (2,2-11,2) 11,20 - - - 11,2 (2,2-12,5)

AWS56PH 5,00 5,00 - - 10,0 (2,2-11,2) 5,60 5,60 - - 11,2 (2,2-12,5)

ASS56PH Cassette 5,00 5,00 - - 10,0 (2,2-11,2) 5,60 5,60 - - 11,2 (2,2-12,5)

ADS56PH 5,00 5,00 - - 10,0 (2,2-11,2) 5,60 5,60 - - 11,2 (2,2-12,5)

FC56PHG 5,00 5,00 - - 10,0 (2,2-11,2) 5,60 5,60 - - 11,2 (2,2-12,5)AWS36PH 3,55 3,55 3,55 - 10,65 4,00 4,00 4,00 - 12,0 ASS36PH Cassette 3,55 3,55 3,55 - 10,65 4,00 4,00 4,00 - 12,0

ADS36PH 3,55 3,55 3,55 - 10,65 4,00 4,00 4,00 - 12,0

FC36PHG 3,55 3,55 3,55 - 10,65 4,00 4,00 4,00 - 12,0

OUTDOOR UNIT MODEL AES125PIH/H3/H3B

A B C D A B C DASS125PH Cassette 12,50 - - - 12,5 (2,7-14,0) 14,00 - - - 14,0 (2,7-16,0)ACS125PH 12,50 - - - 12,5 (2,7-14,0) 14,00 - - - 14,0 (2,7-16,0)

ADS125PH 12,50 - - - 12,5 (2,7-14,0) 14,00 - - - 14,0 (2,7-16,0)

AWS71PH 6,25 6,25 - - 12,5 (2,7-14,0) 7,00 7,00 - - 14,0 (2,7-16,0)

ASS71PH Cassette 6,25 6,25 - - 12,5 (2,7-14,0) 7,00 7,00 - - 14,0 (2,7-16,0)

ACS71PH 6,25 6,25 - - 12,5 (2,7-14,0) 7,00 7,00 - - 14,0 (2,7-16,0)

ADS71PH 6,25 6,25 - - 12,5 (2,7-14,0) 7,00 7,00 - - 14,0 (2,7-16,0)AWS45PH 4,16 4,16 4,16 - 12,5 (2,7-14,0) 4,66 4,66 4,66 - 14,0 (2,7-16,0)ASS45PH Cassette 4,16 4,16 4,16 - 12,5 (2,7-14,0) 4,66 4,66 4,66 - 14,0 (2,7-16,0)

ADS45PH 4,16 4,16 4,16 - 12,5 (2,7-14,0) 4,66 4,66 4,66 - 14,0 (2,7-16,0)

FC45PHG 4,16 4,16 4,16 - 12,5 (2,7-14,0) 4,66 4,66 4,66 - 14,0 (2,7-16,0)

AWS36PH 3,12 3,12 3,12 3,12 12,5 (2,7-14,0) 3,50 3,50 3,50 3,50 14,0 (2,7-16,0)

ASS36PH Cassette 3,12 3,12 3,12 3,12 12,5 (2,7-14,0) 3,50 3,50 3,50 3,50 14,0 (2,7-16,0)

ADS36PH 3,12 3,12 3,12 3,12 12,5 (2,7-14,0) 3,50 3,50 3,50 3,50 14,0 (2,7-16,0)

FC36PHG 3,12 3,12 3,12 3,12 12,5 (2,7-14,0) 3,50 3,50 3,50 3,50 14,0 (2,7-16,0)

Note n.1

Note n.2

Note n.3

Indoor unit models Type

Cooling Heating

Indoor capacity (kW) Total capacity Indoor capacity (kW) Total capacity

kW kW

Connectable Indoor units

1 unit

High-wall

Underceiling

2 units also

mixed

DuctedHigh-wall

Ducted

Floor/Ceiling

Indoor unit models Type

Cooling Heating

Indoor capacity (kW) Total capacity Indoor capacity (kW) Total capacity

kW kW

Connectable Indoor units

1 unit Underceiling

Ducted

2 units also

mixed

High-wall

Ducted

Floor/Ceiling

3 units also

mixed

High-wall

Ducted

Floor/Ceiling

Indoor unit models Type

Cooling Heating

Indoor capacity (kW) Total capacity Indoor capacity (kW) Total capacity

kW kW

Connectable Indoor units

1 unit Underceiling

Ducted

2 units also

mixed

High-wall

Underceiling

Ducted

3 units

High-wall

Ducted

Floor/Ceiling

4 units also

mixed

High-wall

Ducted

Floor/Ceiling

Indoor units names contain one number identifying their nominal capacity in kW (i.e.: 71=7,1kW=25000 BTU/h)

The Indoor units here indicated have the same caracteristics as the Indoor units used with the MultiSet DCInverter systems described in the following pages; the only difference is the type of pcb installed.

The control systems (wireless, wired, weekly timer, system controller, etc...) are equal to those used for the MultiSet DCInverter systems described in the following pages.

Outdoor/Indoor units Matching

PA

CK

AG

EP

AC

KA

GE

77www.argoclima.com

Multipackage DCI features

Straight cooling and heat pump Package DC Inverter R410A can be set with two,

three or four indoor units operating simultaneously; this type of installation is the best

for big shops, open space offices, restaurants,...

The installation of more indoor units in one only big room allows a better diffusion

of the conditioned air

The MultiPackage DC Inverter R410A control systems allow a sophisticated control

of single and multi-package configurations by zones, with a maximum of 256 indoor

units being managed by one only intelligent controller

In addition to single-Package DC Inverter R410A features, change-over functionality

and Cluster control, both in cooling and heating modes

Two-unit matchings (duo) are realized with a 2-way distribution joint kit

Three-unit matchings (trio) are realized with a 3-way distribution joint kit

Four-unit matchings (quartet) are realized with 3 distribution joint kits (2-way),

in tree configuration (1 > 2 > 4)

Special function during heat pump start-up and defrosting cycle to avoid cool air

emission in the room

“I Feel” feature, granting the best comfort conditions

Night set back capability

All MultiPackage DC Inverter R410A systems may be controlled by infrared remote

control with digital 24h timer and temperature sensor indoor or by a special wired

controller with configuration, diagnostic and weekly timer capabilities;

in the following pages are shown all the MultiPackage DC Inverter R410A

control systems

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve

and fuzzy logic managed by a powerful microprocessor

Auto restart after a power supply black out

Electronic protection against over-pressures

Wide operating range with outdoor air temperatures up to -15°C in both cooling

and heating modes

Single-phase (230/1/50) and Three-phase (400/3/50) power supply thanks to

DC Inverter technology low consumption

Double rotary compressor

HIGH WALL INDOOR UNITS

CASSETTE INDOOR UNITS

CEILING INDOOR UNITS

FLOOR/CEILING INDOOR

UNITS

DUCTED INDOOR UNITS

PA

CK

AG

PA

CK

AG

EE

Pipe lines

78 www.argoclima.com

PIPES LENGHT AND DIFFERENCES BETWEEN UNITS IN DUO,

TRIO AND QUARTET CONFIGURATIONS

PIPES DIAMETER (I.U.)

Duo Trio

L+l1 L+l1, L+l2 L+L1+l1, L+L1+l250

L+l2 L+l3 L+L2+l3, L+L2+l4

l1,l2 l1,l2,l3L1+l1, L1+l2

15L2+l3, L2+l4

Max: L2+l4

10l1-l2

l1-l2l1-l3

(L2+l4)-(L1+l1)l2-l3

-- 10

-- 10l2-l1 l4-l3

H1 30

H1 15

H2 H2, H3, H4 H2, H3, H4, H5, H6, H7 0,5

Description Quartet Lenght (m)

Tubing lenght from the Outdoor unit to the farthest Indoor unit

Tubing lenght after the first distribution

Difference between maximum and minimum tubing lenght ,

after the first distribution

l1>l2l1>l2>l3

Min: L1+l1

Max. tubing lenght difference at distribution joint no. 1 L2>L1 L2-L1

Max. tubing lenght difference at distribution joint no. 2l2>l1 l4>l3

Max. height difference between units (Outdoor on top)

Max. height difference between units (Indoor on top)

Max. height difference between Indoor units

36 45 56 71 100 125

6,35(1/4") 6,35(1/4") 6,35(1/4") 9,52(3/8") 9,52(3/8") 9,52(3/8")

12,7(1/2") 12,7(1/2") 12,7(1/2") 15,88(5/8") 15,88(5/8") 15,88(5/8")

Type capacity of indoor units -->

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

PA

CK

AG

EP

AC

KA

GE

79www.argoclima.com

Indoor units table

Dry

AWS36PH l/h 1,9 3 + Auto mm 285x995x203 kg 12

AWS45PH l/h 1,9 3 + Auto mm 285x995x203 kg 12

AWS56PH l/h 2,1 3 + Auto mm 285x995x203 kg 12

AWS71PH l/h 4,0 3 + Auto mm 330x1.140x228 kg 21

ASS36PH l/h 1,2 3 + Auto mm 273x575x575 kg 16

ASS45PH l/h 2,3 3 + Auto mm 273x575x575 kg 18

ASS56PH l/h 2,3 3 + Auto mm 273x575x575 kg 18

- - - - mm 41x730x730 kg 2,5

l/h 3,6 3 + Auto mm 338x860x860 kg 22

- - - - mm 30x860x860 kg 6

l/h 4,6 3 + Auto mm 338x1150x860 kg 27

l/h 6,3 3 + Auto mm 338x1150x860 kg 27

- - - - mm 30x1150x860 kg 8

ADS36PH l/h 1,5 3 + Auto mm 266x926x571 kg 30

- - - - mm 266x926x200 kg 6

ADS45PH l/h 2,3 3 + Auto mm 266x1132x571 kg 35

ADS56PH l/h 2,3 3 + Auto mm 266x1132x571 kg 35

- - - - mm 266x1132x200 kg 7,5

ADS71PH l/h 3,5 3 + Auto mm 310x1000x630 kg 32

ADS100PH l/h 4,2 3 + Auto mm 310x1480x630 kg 47

ADS125PH l/h 6,6 3 + Auto mm 310x1480x630 kg 47

FC36PHG l/h 1,3 3 + Auto mm 680x900x190 kg 23,5

FC45PHG l/h 2,3 3 + Auto mm 680x900x190 kg 23,5

FC56PHG l/h 2,3 3 + Auto mm 680x900x190 kg 23,5

ACS71PH l/h 3,0 3 + Auto mm 210x1180x680 kg 25

ACS100PH l/h 3,9 3 + Auto mm 210x1595x680 kg 33

ACS125PH l/h 5,6 3 + Auto mm 210x1595x680 kg 35

Hi-wall units

Air flowrate (h.m.l.) Fan speeds Sound pressure(h.m.l.) Dimension (HxWxD) Net weight

m3/h 720-600-420 dB(A) 35-31-27

m3/h 720-600-420 dB(A) 35-31-27

m3/h 780-660-480 dB(A) 38-34-30

m3/h 1140-1020-840 dB(A) 41-37-34

Cassette units

m3/h 700-600-500 dB(A) 43-40-37

m3/h 750-630-530 dB(A) 44-40-37

m3/h 750-630-530 dB(A) 44-40-37

ASGM0918 (grille)

ASS71PH (with grille) m3/h 1140-1020-840 dB(A) 47-45-41

ASG0025E (grille)

ASS100PH (with grille) m3/h 1920-1680-1320 dB(A) 53-50-46

ASS125PH (with grille) m3/h 1920-1680-1320 dB(A) 53-50-46

ASG3648E (grille)

Ducted units

m3/h 600-510-440 dB(A) 45-43-40

2-way duct (200 mm each) Plenum

m3/h 875-600-400 dB(A) 45-38-33

m3/h 875-600-400 dB(A) 45-38-33

3-way duct (200 mm each) Plenum

m3/h 1080-900-780 dB(A) 34-30-27

m3/h 1800-1560-1260 dB(A) 38-33-31

m3/h 1980-1560-1320 dB(A) 40-37-33

Floor/ceiling units

m3/h 700-590-500 dB(A) 47-43-38

m3/h 830-760-665 dB(A) 52-49-46

m3/h 830-760-665 dB(A) 52-49-46

Ceiling units

m3/h 1098-900-840 dB(A)38-36-33

m3/h 1650-1380-1200 dB(A) 41-38-35

m3/h 1800-1560-1320 dB(A) 43-40-37

NB: For the indoor units capacity see the matching table.P

AC

KA

GP

AC

KA

GEE

80 www.argoclima.com

Controls & accessories

www.argoclima.com

Schedule timerSchedule timer able to manage up to 64 indoor units with customized programming of all

features, on/off cycles, etc.

Simplified wired remote controllerSimplified wired remote controller to be used with the full range of indoor units; it controls

all the main features

Standard wired remote controllerStandard wired remote controller with full features control, self-diagnostic and centralized

programming capabilities

Infrared remote controller with receiverInfrared remote controller to be used, in matching with a special infrared receiver, with the

full range of indoor units; it shows the operation status of the air-conditioner

Infrared remote controller / i.u. ACInfrared remote controller to be used with underceiling indoor units

Infrared remote controller / i.u. AS-FC

Infrared remote controller to be used with cassette and floor/ceiling indoor units

Infrared remote controller / i.u. HIGH-WALLInfrared remote controller to be used with high-wall indoor units

Remote sensorRemote sensor to be used with the full range of indoor units to detect the room temperature

when no remote controller sensor or body sensor is used: suggested for air-conditioner

systems without remote controller

PA

CK

AG

EP

AC

KA

GE

81www.argoclima.comwww.argoclima.com

Optional distribution joint kit

DDVI 16 Capacity after distribution joint is 16.0 kW or less

DTVP Capacity after distribution joint is 28.0 kW or less

PA

CK

AG

PA

CK

AG

EE

82 www.argoclima.com

Notes:

PA

CK

AG

EP

AC

KA

GE

83www.argoclima.com

Two/Three way modular systems

for installations up to 135 kW/48HP

max 3 outdoor units & 40 indoor units

VR

VR

FF

Two/T

for ins

max 3

Multiset DC Inverter systems demand the respect of precise rules in the engineering of a refrigerant circuit

Argoclima gives to system engineers all support and accessories necessary for a correct implementation of an air conditioner system.

Engineering and design software Distribution kits Expansion valves with electronic control Accessories to change the air with outside

Our organization of Argo technicians and engineers is at Your disposal for the development of projects, the realization of CAD designs, the test/start of the system and the after-sale technical service.

Argoclima Multiset design support software

Multiset V.R.F. DC Inverter

84 www.argoclima.com

VR

FV

RF

85www.argoclima.com

Multiset Vrf Systems Advantages

FOR THOSE WHO PURCHASE AND WHO INSTALL

COST REDUCTION The system uses only two pipes (three in case of systems with heat recovery): the cost and installation time are thus reduced.

FOR THOSE WHO USE AND WHO MAKE MAINTENANCE

CUSTOMIZED SELECTION: The user can select at will the environmental conditions of each area or room to obtain an optimal climate.

A COMFORTABLE ENVIRONMENT: The temperature control reduces the time necessary to achieve the desired conditions, keeping them steadily.

HIGH PERFORMANCE ROTARY COMPRESSORS: The advanced design of the compressors together with the LONG-LIFE system, using cyclic compressors in multiple installations, offer extended service life.

SELF-DIAGNOSIS FUNCTION: In case of failure, both the remote devices and the outdoor units provide the information necessary to become aware of the location and characteristics of the failure, reducing repair and maintenance time.

EASY USE OF THE REMOTE CONTROL: Remote Control allows you to obtain very easily maximum performances from each indoor unit. You can easily select the operation mode (dry/cooling/heating/ventilation), the desired temperature, the air flow volume and direction, etc.

EASY INSTALLATION OF CONTROL SYSTEM: The control system uses a transmission circuit formed by two wires without polarity; in this way, you avoid errors and significantly reduces the time required for the connection.

MINIMAL INVASIVENESS IN THE BUILDING: Pipes small sizes don’t allow to excessively pollute the building in which the system will be installed. This advantage is particularly important in case of structures already existing or under renovation.

INSTALLATION TIME REDUCTION: The accessories for connecting pipes and the modular type of mounting facilitate and accelerate the time required for installation.

VERSATILE CONTROL SYSTEM: The control system allows numerous combinations of individual control, group control and system control.

EASY MODIFICATIONS AND IMPLEMENTATIONS: If it was intended in the design phase, you can expand the system with the addition of indoor and outdoor units in a simple and practical way.

FLEXIBILE MANAGEMENT: The system can have a power ratio between indoor and outdoor units from 50% to 130%.

FOR THOSE WHO DESIGN AND WHO PROPOSE

CONSIDERABLE FLEXIBILITY OF THE TRACK: The high length of refrigerant pipes between indoor and outdoor units makes easier the installation adjustment to the configuration of the building; also the large distances between indoor and outdoor units allow to easily choose the best location for the condensing units.

VR

VR

FF

Mini Multiset V.R.F. DC

AES04MMIH/H3

AES05MMIH/H3

AES06MMIH/H3

Cooling: 11,2 kWHeating: 12,5 kWCooling: 14 kWHeating: 16 kWCooling: 15,5 kWHeating: 17,6 kW

The Mini Multiset V.R.F. DC Inverter System is the new frontier of

technology, specifically thought for residential and light commer-

cial applications

DCI High efficiency DC Inverter Compressor, circuit DCI PAM

(Dc Inverter Pulse Amplitude modulation), maximum of 9 indoor

units connectable to 1 outdoor unit (model AES06MMIH). DC

Inverter Fan

V.R.F. Variable Refrigerant Flow: continuous regulation of the

refrigerant flow rate in the circuit of an air conditioning system

able to give the best in term of comfort, with very high efficiency

levels (E.E.R. up to 4,06 - model AES04MMIH)

R410A The most ecological and efficient refrigerant available for

air conditioning systems of this level of thermal capacity

COMPACT Reduced dimensions of the outdoor unit

WIDE RANGE Three sizes available: 4-5-6 HP

230/400 VOLT Single-phase (230/1/50) and Three-phase

(400/3/50) power supply

150 m Refrigerant circuit of a maximum length of 150 m, to

be realized with a big save of time thanks to the reduced pipe

dimension and to the simple tree structure that makes widening

easy, not requiring any installation of expensive concentrator

apparatus

LAN (Local Area Network) For the interconnection of all the

indoor/outdoor units and the system controls, realized with two

wiring cables without polarization; the intelligent controllers are

able to auto set all the units, simplifying and reducing to minimum

the time-to-start

SILENCE Low sound levels thanks to the special fans and to the

careful study of the air movements in suction

WIDE LIMITS The wide range of outdoor air temperature

supported allows the operation even in extreme conditions:

from -10°C to +43°C in cooling mode from -20°C to +15°C in

heating mode

MATCHIN & CONTROLS Indoor units, controllers (all optional)

and accessories are the same as those of 2 and 3 way Multiset

V.R.F.DCI

86 www.argoclima.com

VR

FV

RF

87www.argoclima.com

Mini Multiset V.R.F. DC

AES04MMIH/H3 AES05MMIH/H3 AES06MMIH/H3

HP 4 5 611,2 12,5 14,0 16,0 15,5 17,6

BTU/h 38.200 42.700 47.800 54.600 52.900 60.0009.630 10.750 12.040 13.760 13.330 15.140

E.E.R. / C.O.P. 4,06 4,34 3,66 4,1 3,39 3,84m³/h 6.000 6.000 6.000

51/48 51/48 52/49230/1/50 - 400/3/50 230/1/50 - 400/3/50 230/1/50 - 400/3/502,76 2,88 3,83 3,90 4,57 4,58

R410A R410A R410A9,52(3/8") 9,52(3/8") 9,52(3/8")15,88(5/8") 15,88(5/8") 19,05 (3/4")

no. 6 8 9m 150 150 150Kg 3,5 3,5 3,5m 15 15 15m 50 50 50m 40 40 40Kg 104 104 104mm 1.200x940x340 1.200x940x340 1.200x940x341

INVERTER outdoor units

Features units Cooling Heating Cooling Heating Cooling Heating

Cooling/Heating capacitykW

kcal/h(kW/kW)

Air flowrate (h.)Sound pressure (normal/silent mode) dB(A)Power supply V/Ph/HzRunning consumption kWCompressor type DC Inverter DC Inverter DC InverterRefrigerant typeLiquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Max. number of connectable indoor unitsMax. pipe lenght Gas standard chargeMax. distance between indoor unitsMax. height between units (Outdoor on top)Max. height between units (Indoor on top)Net weight OutdoorNet dimension Outdoor (H./W./D.)

VR

VR

FF

Multiset V.R.F. DC

88 www.argoclima.com

DCI + SAC DC Inverter Compressor + Scroll AC Compressor, the

perfect matching for a high efficiency system with capacity up to 48HP,

automatically modulated by the DCI PAM (Dc Inverter Pulse Amplitude

modulation) circuit on a maximum of 40 indoor units connected.

V.R.F. Variable Refrigerant Flow: continuous regulation of the

refrigerant flow rate in the circuit of an air conditioning system able to

give the best in term of comfort, with very high efficiency levels (COP

up to 4,09).

R410A The most ecological and efficient refrigerant available for air

conditioning systems of this level of thermal capacity.

TWO WAY Two-way system with possibility of condensing and

indoor units increase thanks to the simple tree refrigerant circuit.

THREE WAY New three-way solution with heat recovery, giving the

possibility of a simultaneous independent operation in cooling and/or

heating modes of each indoor unit.

HFC= -21% Reduction of the total refrigerant volume of about 21%

in comparison with the previous systems.

300 m Refrigerant circuit of a maximum length of 300 m, to be realized

with a big save of time thanks to the reduced pipe dimension and to

the simple tree structure that makes widening easy, not requiring any

installation of expensive concentrator apparatus.

LAN (Local Area Network) for the interconnection of all the indoor/

outdoor units and the system controls, realized with two wiring cables

without polarization; the intelligent controllers are able to auto set all

the units, simplifying and reducing to minimum the time-to-start.

LONG LIFE A special electronic system controls the operating cycles

of the compressors, distributing the load and extending the efficiency

in the time.

BACK UP The system is able to activate the automatic back-up of the condensing units in error or stopped; the sophisticated control

system compensates the bad operation of the blocked outdoor unit, distributing the thermal power to the other outdoor units of the

multiple configuration system.

SILENCE For the first time the sound levels are lower than 52 dB; thanks to the special fans and to the careful study of the air

movements in suction, the sound levels have been reduced of more than 4 dB in comparison with the previous models.

WIDE RANGE The wide range of outdoor air temperature supported allows the operation even in extreme conditions:

from -10°C to +43°C in cooling mode

from -20°C to +15°C in heating mode

FREE PLACE The condensing units in multiple configuration can be installed at a distance of only 10 cm or very far one from the other,

even on different stages of the building; this feature makes the system more adaptable to the various circumstances.

VR

FV

RF

89www.argoclima.com

Outdoor Units 2-Way Systems

Main features:

- compactness, making units easier to position;

- smaller pipe works, making material costs lower;

- flexibility of installation;

- high efficiency (C.O.P. at the top of the range: 3,90 average

cooling/heating for the 8HP units)

- reduced life cycle costs;

- accurate capacity control;

- possibility to choose among a wide range of control options.

Maximum number of Outdoor units connectable: 3.

Maximum total power of the system: 135 kW (48 HP).

Maximum number of Indoor units connectable: 40.

Twin Rotary DC Inverter compressor, highly efficient at low

rotation frequencies.

R410A HFC refrigerant.

Fan with direct current motor that allows a consumption reduction

of about 50% and a speed modulation up to 16 steps in spite

of the usual 4 steps of the alternate current motors; this performance

increases the efficiency of the thermodynamic system which is

able to best adapt to the variations of temperature and thermal load

of the rooms.

The use of a special oil sensor allows, for the first time in the world,

to keep under control the lubrification of the mechanical parts of the

compressor.

Special air intakes and Double Chamber construction technology

allowed to unify the dimensions of the units, making easier the closing

up for multiple installations in which two units can be placed at

a distance of only 10 cm one from the other, the smaller distance

available.

Low sound level thanks to a special fan made of resin and a particular

resin grille, designed and used for these units in order to minimize

air pressure drops.

New high efficiency Cross-Arranged heat exchanger with three-way

suction, divided in two sections with double control of defrosting cycle.

Pressure control automatic and by software on PC.

Pipe connection indoor the unit frame through a special space to

be closed back when the installation is finished.

Equipped with Fault-Tolerant system granting in multiple installations the operation of the air conditioning system also in case

of total stop of one condensing unit.

Support to Long-Life system that, in multiple installations, allows a cyclic use of the condensing units, granting a balance

of the compressors activity.

Wide range of outdoor air temperature: from -10°C to +43°C in cooling mode and from -20°C to +15°C in heating mode.

Maximum length of the refrigerant circuit extended to 300 m.

The refrigerant circuit doesn’t require distribution apparatus downstream of the unit as it can be realized with a tree structure using

only the special distributor accessories; this feature facilitates any type of system widening, by adding both outdoor and indoor units.

Three-phase auto sense power supply 380-415/3N/50Hz.

VR

VR

FF

Technical data

90 www.argoclima.com

AES08MI2HA AES10MI2HA AES12MI2HA

22,40 / 25,00 28,00 / 31,50 33,50 / 37,50

E.E.R. / C.O.P. 3,74 / 4,05 3,54 / 4,06 3,50 / 3,91

m³/h 9.000 9.600 10.800

54,5 / 51,5 55 / 52 56 / 53

65,5 66,5 67,5

400/3N/50 400/3N/50 400/3N/50

5,99 / 6,17 7,90 / 7,75 9,58 / 9,60

A 9,20 / 9,50 12,30 / 12,00 14,90 /14,90

R410A R410A R410A

9,52(3/8") 9,52(3/8") 12,70(1/2")

19,05(3/4") 22,22(7/8") 25,40(1")

6,35(1/4") 6,35(1/4") 6,35(1/4")

m 300 300 300

Kg 12 12 12

°C

% 50 - 130 50 - 130 50 - 130

N° 13 16 19

m 50 50 50

m 40 40 40

Kg 245 295 295

mm 1.887x890(+60)x890 1.887x890(+60)x890 1.887x890(+60)x890

2-way INVERTER OUTDOOR UNIT

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Running consumption (cooling/heating) kW

Running current

Compressor type Twin Rotary DCI (N°1) Twin Rotary DCI+Scroll(N°2) Twin Rotary DCI+Scroll(N°2)

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter (suction) mm(inch")

Balance pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Max. height between units (Outdoor on top)

Max. height between units (Indoor on top)

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

AES14MI2HA AES16MI2HA

40,00 / 45,00 45,00 / 50,00

E.E.R. / C.O.P. 3,45 / 3,91 3,38 / 3,79

m³/h 12.000 13.200

61 / 58 62 / 59

71,5 72

400/3N/50 400/3N/50

11,60 / 11,50 13,30 / 13,20

A 18,60 /18,50 21,30 /21,20

R410A R410A

12,70(1/2") 12,70(1/2")

25,40(1") 28,58(1-1/8")

6,35(1/4") 6,35(1/4")

m 300 300

Kg 13 13

°C

% 50 - 130 50 - 130

N° 23 26

m 50 50

m 40 40

Kg 345 345

mm 1.887x890(+60)x890 1.887x890(+60)x890

2-way INVERTER OUTDOOR UNIT

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Running consumption (cooling/heating) kW

Running current

Compressor type Twin Rotary DCI+Scroll(N°3) Twin Rotary DCI+Scroll(N°3)

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter (suction) mm(inch")

Balance pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 -10

Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Max. height between units (Outdoor on top)

Max. height between units (Indoor on top)

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

VR

FV

RF

91www.argoclima.com

Outdoor units matchings - technical data

CAPACITY CLASSES (HP) 18 HP 20 HP 22 HP

AES10+AES08 MI2HA AES10+AES10 MI2HA AES12+AES10 MI2HA

50,40 / 56,50 56,00 / 63,00 61,50 / 69,00

E.E.R. / C.O.P. 3,63 / 4,06 3,54 / 3,80 3,51 / 3,97

m³/h 9.600 + 9.000 9.600 x 2 10.800 + 9.600

58 / 55 58 / 55 58,5 / 55,5

69 69,5 69,5

400/3N/50 400/3N/50 400/3N/50

13,9 / 13,9 15,8 / 15,5 17,5 / 17,4

A 21,60 / 21,60 24,7 / 24,2 27,2 / 27,0

R410A R410A R410A

15,88(5/8") 15,88(5/8") 15,88(5/8")

28,58(1-1/8") 28,58(1-1/8") 28,58(1-1/8")

6,35(1/4") 6,35(1/4") 6,35(1/4")

m 300 300 300

Kg 12,0 x 2 12,0 x 2 12,0 x 2

°C

% 50-130 50-130 50-130

N° 29 33 36

Kg 295 + 245 295 x 2 295 x 2

mm 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60)

Outdoor units matchings

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll

Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve

Refrigerant type

Liquid pipe diameter after 1° distributor kit mm(inch")

Gas pipe diameter after 1° distributor kit mm(inch")

Diameter of balancing pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

CAPACITY CLASSES (HP) 24 HP 26 HP 28 HP

AES14+AES10 MI2HA AES16+AES10 MI2HA AES16+AES12 MI2HA

68,00 / 76,50 73,00 / 81,50 78,50 / 87,50

E.E.R. / C.O.P. 3,49 / 3,96 3,44 / 3,88 3,43 / 3,84

m³/h 12.000 + 9.600 13.200 + 9.600 13.200 + 10.800

62 / 59 63 / 60 63 / 60

72,5 73 73,5

400/3N/50 400/3N/50 400/3N/50

19,5 / 19,3 21,2 / 21,0 22,9 / 22,8

A 30,8 / 30,4 33,6 / 33,3 36,3 / 36,2

R410A R410A R410A

15,88(5/8") 19,05(3/4") 19,05(3/4")

28,58(1-1/8") 31,75(1-1/4") 31,75(1-1/4")

6,35(1/4") 6,35(1/4") 6,35(1/4")

m 300 300 300

Kg 13,0 + 12,0 13,0 + 12,0 13,0 + 12,0

°C

% 50-130 50-130 50-130

N° 40 40 40

Kg 345 + 295 345 + 295 345 + 295

mm 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60)

Outdoor units matchings

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll

Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve

Refrigerant type

Liquid pipe diameter after 1° distributor kit mm(inch")

Gas pipe diameter after 1° distributor kit mm(inch")

Diameter of balancing pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

CAPACITY CLASSES (HP) 30 HP 32 HP 34 HP

AES16+AES14 MI2HA AES16+AES16 MI2HA AES 14+10+10 MI2HA

85,00 / 95,00 90,00 / 100,00 96,00 / 108,00

E.E.R. / C.O.P. 3,41 / 3,85 3,38 / 3,79 3,50 / 4,00

m³/h 13.200 + 12.000 13.200 x 2 12.000 + 9.600 x 2

64,5 / 61,5 65 / 62 63 / 60

74,5 75 73,5

400/3N/50 400/3N/50 400/3N/50

24,9 / 24,7 26,6 / 26,4 27,4 / 27,0

A 39,9 / 39,6 42,7 / 42,3 43,1 / 42,5

R410A R410A R410A

19,05(3/4") 19,05(3/4") 19,05(3/4")

31,75(1-1/4") 31,75(1-1/4") 31,75(1-1/4")

6,35(1/4") 6,35(1/4") 6,35(1/4")

m 300 300 300

Kg 13,0 x 2 13,0 x 2 13,0+12,0 x 2

°C

% 50-130 50-130 50-130

N° 40 40 40

Kg 345 x 2 345 x 2 345 + 295 x 2

mm 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x2.870x890(+60)

Outdoor units matchings

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll

Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve

Refrigerant type

Liquid pipe diameter after 1° distributor kit mm(inch")

Gas pipe diameter after 1° distributor kit mm(inch")

Diameter of balancing pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

VR

VR

FF

Outdoor units matchings - technical data

92 www.argoclima.com

CAPACITY CLASSES (HP) 36 HP 38 HP 40 HP

AES 16+10+10 MI2HA AES 16+12+10 MI2HA AES 16+14+10 MI2HA

101,00 / 113,00 107,00 / 119,00 113,00 / 127,00

E.E.R. / C.O.P. 3,47 / 3,94 3,47 / 3,68 3,45 / 3,91

m³/h 13.200 + 9.600 x 2 13.200 +10.800 + 9.600 13.200 +12.000 + 9.600

63,5 / 60,5 63,5 / 60,5 65 / 62

74 74,5 75

400/3N/50 400/3N/50 400/3N/50

29,1 / 28,7 30,8 / 30,6 32,8 / 32,5

A 45,8 / 45,2 48,0 / 48,0 52,0 / 52,0

R410A R410A R410A

19,05(3/4") 19,05(3/4") 19,05(3/4")

38,10(1-1/2") 38,10(1-1/2") 38,10(1-1/2")

6,35(1/4") 6,35(1/4") 6,35(1/4")

m 300 300 300

Kg 13,0+12,0 x 2 13,0+12,0 x 2 13,0 x 2+12,0

°C

% 50-130 50-130 50-130

N° 40 40 40

Kg 345 + 295 x 2 345 + 295 x 2 345 x 2 + 295

mm 1.887x2.870x890(+60) 1.887x2.870x890(+60) 1.887x2.870x890(+60)

Outdoor units matchings

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll

Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve

Refrigerant type

Liquid pipe diameter after 1° distributor kit mm(inch")

Gas pipe diameter after 1° distributor kit mm(inch")

Diameter of balancing pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

CAPACITY CLASSES (HP) 42 HP 44 HP

AES 16+16+10 MI2HA AES 16+16+12 MI2HA

118,00 / 132,00 124,00 / 138,00

E.E.R. / C.O.P. 3,42 / 3,86 3,43 / 3,83

m³/h 13.200 x 2 + 9.600 13.200 x2 + 10.800

65,5 / 62,5 65,5 / 62,5

75,5 76

400/3N/50 400/3N/50

34,5 / 34,2 36,2 / 36,0

A 55,0 / 54,0 57,0 / 57,0

R410A R410A

19,05(3/4") 19,05(3/4")

38,10(1-1/2") 38,10(1-1/2")

6,35(1/4") 6,35(1/4")

m 300 300

Kg 13,0 x 2+12,0 13,0 x 2+12,0

°C

% 50-130 50-130

N° 40 40

Kg 345 x 2 + 295 345 x 2 + 295

mm 1.887x2.870x890(+60) 1.887x2.870x890(+60)

Outdoor units matchings

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary+Scroll Twin Rotary+Scroll

Refrigerant control Electr. Exp. Valve Electr. Exp. Valve

Refrigerant type

Liquid pipe diameter after 1° distributor kit mm(inch")

Gas pipe diameter after 1° distributor kit mm(inch")

Diameter of balancing pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

CAPACITY CLASSES (HP) 46 HP 48 HP

AES 16+16+14 MI2HA AES 16+16+16 MI2HA

130,00 / 145,00 135,00 / 150,00

E.E.R. / C.O.P. 3,40 / 3,83 3,38 / 3,79

m³/h 13.200 x 2 + 12.000 13.200 x 3

66,5 / 63,5 67,0 / 64,0

76,5 77

400/3N/50 400/3N/50

38,2 / 37,9 39,9 / 39,6

A 61,0 / 61,0 64,0 / 64,0

R410A R410A

19,05(3/4") 19,05(3/4")

38,10(1-1/2") 38,10(1-1/2")

6,35(1/4") 6,35(1/4")

m 300 300

Kg 13,0 x 3 13,0 x 3

°C

% 50-130 50-130

N° 40 40

Kg 345 x 3 345 x 3

mm 1.887x2.870x890(+60) 1.887x2.870x890(+60)

Outdoor units matchings

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary+Scroll Twin Rotary+Scroll

Refrigerant control Electr. Exp. Valve Electr. Exp. Valve

Refrigerant type

Liquid pipe diameter after 1° distributor kit mm(inch")

Gas pipe diameter after 1° distributor kit mm(inch")

Diameter of balancing pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

VR

FV

RF

93www.argoclima.com

Outdoor Units 3-Way Systems

Main features:

Automatic change-over between cooling and heating modes for

each indoor unit; this feature, based on the three-way technology

with heat recovery, allows a fully independent operation of each

indoor unit.

R410A HFC refrigerant.

Twin Rotary DC Inverter compressor, highly efficient at low rotation

frequencies, matching with a Scroll Constant-Speed compressor .

Fan with direct current motor that allows a consumption reduction

of about 50% and a speed modulation up to 16 steps in spite of

the usual 4 steps of the alternate current motors; this performance

increases the efficiency of the thermodynamic system which

is able to best adapt to the variations of temperature and thermal

load of the rooms .

The use of a special oil sensor allows, for the first time in the

world,to keep under control the lubrification of the mechanical

parts of the compressor.

Special air intakes and Double Chamber construction technology

allowed to unify the dimensions of the units, making easy

the closing up for multiple installations in which two units can

be placed at a distance of only 10 cm one from the other,

the smaller distance available.

Low sound level thanks to a special fan made of resin and

a particular resin grille, designed and used for these units in order

to minimize air pressure drops.

New high efficiency Cross-Arranged heat exchanger with

three-way suction, divided in two sections with double control

of defrosting cycle.

Pressure control automatic and by software on PC.

Pipe connection indoor the unit frame through a special space to

be closed back when the installation is finished.

Equipped with Fault-Tolerant system granting in multiple

installations the operation of the air conditioning system also

in case of total stop of one condensing unit.

Support to Long-Life system that, in multiple installations,

allows a cyclic use of the condensing units, granting a balance

of the compressors activity.

“On Demand” feature allows to best use the characteristics of DC Inverter technology, setting three different levels of electric power

on which are automatically based the control microprocessors so that to achieve the maximum performances with reduction of

electric consumption.

Extra range of outdoor air temperature: from -10°C to +43°C in cooling mode and from -20°C to +15°C in heating mode.

Maximum length of the refrigerant circuit extended to 300 m.

The refrigerant circuit doesn’t require distribution apparatus downstream of the unit as it can be realized with a tree structure using

only the special distributor accessories; this feature facilitates any type of system widening, by adding both outdoor and indoor units.

Three-phase auto sense power supply 380-415/3N/50Hz.

VR

VR

FF

Technical data

94 www.argoclima.com

AES08MI3H AES10MI3H AES12MI3H

22,40 / 25,00 28,00 / 31,50 33,50 / 37,50

E.E.R. / C.O.P. 3,78 / 4,09 3,45 / 3,95 3,41 / 3,81

m³/h 9.000 9.600 10.800

54,5/51,5 55/52 56/53

65,5 66 67

400/3N/50 400/3N/50 400/3N/50

5,93 / 6,11 8,12 / 7,97 9,82 / 9,84

A 9,20 / 9,50 12,30 / 12,0 14,9 / 14,9

R410A R410A R410A

9,52(3/8") 9,52(3/8") 12,70(1/2")

19,05(3/4") 22,22(7/8") 25,40(1")

15,88(5/8") 19,05(3/4") 19,05(3/4")

6,35(1/4") 6,35(1/4") 6,35(1/4")

m 300 300 300

Kg 12 12 12

°C

% 50 - 130 50 - 130 50 - 130

no. 13 16 19

m 50 50 50

m 40 40 40

Kg 290 290 290

mm 1.887x890x890(+60) 1.887x890x890(+60) 1.887x890x890(+60)

AES14MI3H AES16MI3H

40,00 / 45,00 45,00 /50,00

E.E.R. / C.O.P. 3,45 / 3,91 3,38 / 3,79

m³/h 12.000 13.200

60/57 61/58

71 72

400/3N/50 400/3N/50

11,6 /11,5 13,3 /13,2

A 19,0 / 18,9 21,8 / 21,6

R410A R410A

12,70(1/2") 12,70(1/2")

25,40(1") 28,58(1-1/8")

22,22(7/8") 22,22(7/8")

6,35(1/4") 6,35(1/4")

m 300 300

Kg 15 15

°C

% 50 - 130 50 - 130

no. 23 26

m 50 50

m 40 40

Kg 350 350

mm 1.887x890x890(+60) 1.887x890x890(+60)

3-way INVERTER OUTDOOR UNITS

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary DCInv.+ Scroll CS Twin Rotary DCInv.+ Scroll CS Twin Rotary DCInv.+ Scroll CS

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter (suction) mm(inch")

Gas pipe diameter (discharge) mm(inch")

Balance pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Max. height between units (Outdoor on top)

Max. height between units (Indoor on top)

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

3-way INVERTER OUTDOOR UNITS

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary DCInv.+ Scroll CS Twin Rotary DCInv.+ Scroll CS

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter (suction) mm(inch")

Gas pipe diameter (discharge) mm(inch")

Balance pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Max. height between units (Outdoor on top)

Max. height between units (Indoor on top)

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

VR

FV

RF

95www.argoclima.com

Outdoor units matchings - technical data

CAPACITY CLASSES (HP) 18 HP 20 HP 22 HP 24 HP

AES 10+08 MI3H AES 10+10 MI3H AES 12+10 MI3H AES 14+10 MI3H

50,40 / 56,50 56,00 / 63,00 61,50 / 69,00 68,00 / 76,50

E.E.R. / C.O.P. 3,57 / 4,01 3,46 / 3,96 3,44 / 3,88 3,45 / 3,92

m³/h 9.600 + 9.000 9.600 x 2 10.800 + 9.600 12.000 + 9.600

58 / 55 58 / 55 58,5 / 55,5 58 / 55

69 69 69,5 72,5

400/3N/50 400/3N/50 400/3N/50 400/3N/50

14,1 / 14,1 16,2 / 15,9 17,9 / 17,8 19,7 / 19,5

A 22,6 / 22,6 26,0 / 25,5 28,7 / 28,5 31,9 / 31,6

R410A R410A R410A R410A

15,88(5/8") 15,88(5/8") 15,88(5/8") 15,88(5/8")

28,58(1-1/8") 28,58(1-1/8") 28,58(1-1/8") 28,58(1-1/8")

22,22((7/8") 22,22((7/8") 25,4(1") 25,4(1")

9,52(3/8") 9,52(3/8") 9,52(3/8") 9,52(3/8")

m 300 300 300 300

Kg 12,0 x 2 12,0 x 2 12,0 x 2 13,0 + 12,0

°C

% 50 - 130 50 - 130 50 - 130 50 - 130

N° 29 33 36 40

Kg 295 + 245 295 x 2 295 x 2 345 + 295

mm 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60)

CAPACITY CLASSES (HP) 26 HP 28 HP 30 HP 32 HP

AES 16+10 MI3H AES 16+12 MI3H AES 16+14 MI3H AES 16+16 MI3H

73,00 / 81,50 78,50 / 87,50 85,00 / 95,00 90,00 / 100,00

E.E.R. / C.O.P. 3,41 / 3,84 3,40 / 3,80 3,41 / 3,85 3,38 / 3,79

m³/h 13.200 + 9.600 13.200 + 10.800 13.200 + 12.000 13.200 x 2

60 / 57 60,5 / 57,5 61 / 58 61,5 / 58,5

73 73,5 74,5 75

400/3N/50 400/3N/50 400/3N/50 400/3N/50

21,4 / 21,2 23,1 / 23,0 24,9 / 24,7 26,6 / 26,4

A 34,7 / 34,4 37,5 / 37,3 40,8 / 40,5 43,6 / 43,3

R410A R410A R410A R410A

19,05(3/4") 19,05(3/4") 19,05(3/4") 19,05(3/4")

28,58(1-1/8") 1-3/8" 1-3/8" 1-3/8"

25,4(1") 28,58(1-1/8") 28,58(1-1/8") 28,58(1-1/8")

9,52(3/8") 9,52(3/8") 9,52(3/8") 9,52(3/8")

m 300 300 300 300

Kg 15,0 + 12,0 15,0 + 12,0 13,0 x 2 15,0 x 2

°C

% 50 - 130 50 - 130 50 - 130 50 - 130

N° 40 40 40 40

Kg 640 640 700 700

mm 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60) 1.887x1.880x890(+60)

Outdoor units matchings

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll

Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve

Refrigerant type

Liquid pipe diameter after 1° distributor kit mm(inch")

Gas pipe diameter after 1° distributor kit mm(inch")

Discharge pipe diameter after 1° distributor kit mm(inch")

Diameter of balancing pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

Outdoor units matchings

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll

Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve

Refrigerant type

Liquid pipe diameter after 1° distributor kit mm(inch")

Gas pipe diameter after 1° distributor kit mm(inch")

Discharge pipe diameter after 1° distributor kit mm(inch")

Diameter of balancing pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

VR

VR

FF

Outdoor units matchings - technical data

96 www.argoclima.com

CAPACITY CLASSES (HP) 34 HP 36 HP 38 HP 40 HP

AES 14+10+10 MI3H AES 16+10+10 MI3H AES 16+12+10 MI3H AES 14+14+10 MI3H

96,00 / 108,00 101,00 / 113,00 107,00 / 119,00 113,00 / 127,00

E.E.R. / C.O.P. 3,45 / 3,93 3,41 / 3,88 3,42 / 3,84 3,42 / 3,88

m³/h 12.000 + 9.600 x 2 13.200 + 9.600 x 2 13.200 +10.800 + 9.600 13.200 +12.000 + 9.600

61 / 58 61,5 / 58,5 61,5 / 58,5 62 / 59

73,5 74 74 75,5

400/3N/50 400/3N/50 400/3N/50 400/3N/50

27,8 / 27,5 29,1 / 28,7 31,3 / 31,0 33,0 / 32,7

A 45,1 / 44,6 48,0 / 47,2 51,0 / 50,0 54,0 / 54,0

R410A R410A R410A R410A

19,05(3/4") 19,05(3/4") 19,05(3/4") 19,05(3/4")

1-3/8" 1-5/8" 1-5/8" 1-5/8"

28,58(1-1/8") 28,58(1-1/8") 1-3/8" 1-3/8"

9,52(3/8") 9,52(3/8") 9,52(3/8") 9,52(3/8")

m 300 300 300 300

Kg 15,0+12,0 x 2 15,0+12,0 x 2 15,0+12,0 x 2 15,0 x 2+12,0

°C

% 50 - 130 50 - 130 50 - 130 50 - 130

N° 40 40 40 40

Kg 930 930 930 990

mm 1.887x2.870x890(+60) 1.887x2.870x890(+60) 1.887x2.870x890(+60) 1.887x2.870x890(+60)

CAPACITY CLASSES (HP) 42 HP 44 HP 46 HP 48 HP

AES 16+16+10 MI3H AES 16+16+12 MI3H AES 16+16+14 MI3H AES 16+16+16 MI3H

118,00 / 132,00 124,00 / 138,00 130,00 / 145,00 135,00 / 150,00

E.E.R. / C.O.P. 3,40 / 3,84 3,41 / 3,81 3,40 / 3,83 3,38 / 3,79

m³/h 13.200 x 2 + 9.600 13.200 x2 + 10.800 13.200 x 2 + 12.000 13.200 x 3

62,5 / 59,5 62,5 / 59,5 63 / 60 63 / 60

75,5 76 76,5 77

400/3N/50 400/3N/50 400/3N/50 400/3N/50

34,7 / 34,4 36,4 / 36,2 38,2 / 37,9 39,9 / 39,6

A 57,0 / 56,0 60,0 / 59,0 63,0 / 62, 0 65,0 / 65,0

R410A R410A R410A R410A

19,05(3/4") 19,05(3/4") 19,05(3/4") 19,05(3/4")

1-5/8" 1-5/8" 1-5/8" 1-5/8"

1-3/8" 1-3/8" 1-3/8" 1-3/8"

9,52(3/8") 9,52(3/8") 9,52(3/8") 9,52(3/8")

m 300 300 300 300

Kg 15,0 x 2+12,0 15,0 x 2+12,0 15,0 x 3 15,0 x 3

°C

% 50 - 130 50 - 130 50 - 130 50 - 130

N° 40 40 40 40

Kg 990 990 1050 1050

mm 1.887x2.870x890(+60) 1.887x2.870x890(+60) 1.887x2.870x890(+60) 1.887x2.870x890(+60)

Outdoor units matchings

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll

Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve

Refrigerant type

Liquid pipe diameter after 1° distributor kit mm(inch")

Gas pipe diameter after 1° distributor kit mm(inch")

Discharge pipe diameter after 1° distributor kit mm(inch")

Diameter of balancing pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Net weight Outdoor

Net dimension Outdoor (H./W./D.)

Outdoor units matchings

Units

Cooling/Heating capacity kW

(kW/kW)

Air flowrate (h.)

Sound pressure (normal/silent mode) dB(A)

Sound power (normal mode) dB(A)

Power supply V/Ph/Hz

Power input (cooling/heating) kW

Running current (cooling/heating)

Compressor type Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll Twin Rotary+Scroll

Refrigerant control Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve Electr. Exp. Valve

Refrigerant type

Liquid pipe diameter after 1° distributor kit mm(inch")

Gas pipe diameter after 1° distributor kit mm(inch")

Discharge pipe diameter after 1° distributor kit mm(inch")

Diameter of balancing pipe mm(inch")

Max. pipe lenght

Gas standard charge

Operating limits (cooling/heating) -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15 -10 ~ +43 / -20 ~ +15Capacity ratio of indoor unit to outdoor unit

Connectable indoor units

Net weight Outdoor

Net dimension Outdoor (H./W./D.)V

RF

VR

F

97www.argoclima.com

Control Systems / Dimensions

VR

VR

FF

Mini Multiset V.R.F. DC

98 www.argoclima.com

part A part B part C part D part E part F part G part H part I part JPosition

Gas pipe

Gas pipe

Gas pipe

Gas pipe

Gas pipe

Liquid pipe

Liquid pipe Liquid pipe

Liquid pipe

Liquid pipe

insulator

insulator

insulator

insulator

insulator

insulator

insulator

insulator

insulator

insulator

Dimension

VR

FV

RF

99www.argoclima.com

Solenoid valve controller

M3 EVVC (B)

Solenoid valve kits for 3 - way sy

M3 EVV 22-56B (for 22-56 models of indoor units)

It is possible to connect 1 only solenoid valve kit controlling a group of indoor units, with a total capacity up to 5,6 kW.

All the indoor units of the group will operate in the same mode (cooling or heating)

M3 EVV 73-140B (for 73-140 models of indoor units)

It is possible to connect 1 only solenoid valve kit controlling a group of indoor units, with a total capacity up to 14 kW.

All the indoor units of the group will operate in the same mode (cooling or heating)

In case 1 only solenoid valve kit is used to control a group of indoor units, only 1 control must be used for the whole group

VR

VR

FF

Distribution joint kits for 3 - way systems

100 www.argoclima.com

Position

Dimension

Part A

ø38.1

Part B

ø31.75

Part C

ø28.58

Part D

ø25.4

Part E

ø22.22

Part F

ø19.05

Part G

ø15.88

Part H

ø12.7

Part I

ø9.52

Part J

ø6.35

p p g ( )

M3DDV22

M3DDVE68

M3DDV135

Suction pipe Liquid pipeDischarge pipe

GH

HG

G

G

G

F H

HH

H II H

HIH

H

H

55

9212

145 55

40

777

186

136

69

235

Insulator Insulator Insulator

210

FFG FF

F

M3DDV68

M3DDVE135

Suction pipe Liquid pipeDischarge pipe

Insulator Insulator

Insulator

G F E E F GEF

G

H IHI

IH

A CB

A

B

B

BA

CD

ED F CC E F

F

DC

ED

C

D 130

340

G

G

G

50

B

B

B

B

C

615

375

180

31566

105 112

230

C

C

C

490300

126112

112

53

C

Suction pipe Liquid pipeDischarge pipe

Insulator InsulatorInsulator

I H IH

IH

GF E E F GEF

G

C

DE

CC DE F

F

C

D F G

G

EDC

FE

D

DE

50340

130

G

G

G

C

C

490300

C

112

126

D

D

DC

490300

12610183

230230

Suction pipeDischarge pipe

Liquid pipe

Insulator Insulator

G F E E F GEF

G

H IHI

IH

B

B B

EC DA FF AD CE

AC

DEF

HG

130

340

G

G

G

50B

BB

C

CC

F

90 105 11245

55

Suction pipe Liquid pipeDischarge pipe

Insulator Insulator Insulator

I H IH

IH

G F E E F GEF

GC

C

C

DE

DE F

F

D

D

DEF DEF EC

E

F

F

GHG

50340

130

G

G

G

300C

C

C

C

112

D

D

300

230230

126

16

F

55

74

112 126

16

F

55

LEGENDA :

letter in circle = female side

letter not in circle = male sideFF

VR

FV

RF

101www.argoclima.com

AWF 22 - 28 - 36 / AWS 56 - 73

AWF 22 - 28 - 36

AWS 56 - 73

High wall indoor unit for Mini Multiset and Multiset V.R.F. DC Inverter systems

New flat panel unit for 2,2 – 2,8 and 3,6 kW models: compact and elegant with its white pearl coloured panel, this new unit can be

easily integrated in every type of furniture

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room

Night set back capability

To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)

“I Feel” feature and temperature sensor indoor the remote control

Dry function

New three-speed tangential fan by remote control, granting a better and low noise air diffusion

Horizontal flap swinging or to be set to a fixed position by remote control

Vertical flap by manual control

Washable air filter

Three-way condensate discharge (right, central and left)

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

VR

VR

FF

Technical data

102 www.argoclima.com

PRODUCT NAME AWF22MH AWF28MH AWF36MH

2,20 2,50 2,80 3,20 3,60 4,20

BTU/h 7.500 8.520 9.550 10.920 12.280 14.320

1.890 2.150 2.410 2.750 3.100 3.610

540-450-360 540-450-360 600-510-390

l/h 1,3 1,6 2,0

n° 3 + Auto 3 + Auto 3 + Auto

35-32-28 35-32-28 37-33-29

46-43-39 46-43-39 48-44-40

230/1/50 230/1/50 230/1/50

0,037 0,038 0,037 0,038 0,043 0,044

R410A R410A R410A

6,35(1/4") 6,35(1/4") 6,35(1/4")

12,70(1/2") 12,70(1/2") 12,70(1/2")

Kg 10,0 10,0 10,0

mm 285x825x217 285x825x217 285x825x217

Features Units Cooling Heating Cooling Heating Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

PRODUCT NAME AWS56MH AWS73MH

5,60 6,30 7,30 8,00

BTU/h 19.100 21.480 24.890 27.280

4.820 5.420 6.280 6.880

720-600-480 960-840-600

l/h 2,3 4,0

n° 3 + Auto 3 + Auto

36-32-28 42-38-35

47-33-39 53-49-46

230/1/50 230/1/50

0,033 0,033 0,052 0,052

R410A R410A

6,35(1/4") 9,52(3/8")

12,70(1/2") 15,88(5/8")

Kg 14 21

mm 285x995x203 330x1.140x228

Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

VR

FV

RF

103www.argoclima.com

ASS 22-28-36-45-56

Four-way cassette indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room

Night set back capability

To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)

“I Feel” feature and temperature sensor indoor the remote control

Dry function

New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion

Horizontal flap swinging or to be set on a fixed position by remote control

Washable air filter

Integrated pump for condensate discharge

Special anti-dripping system on the four air outlets

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

VR

VR

FF

104 www.argoclima.com

Technical data

PRODUCT NAME ASS22MH ASS28MH

2,20 2,50 2,80 3,20

BTU/h 7.500 8.520 9.550 10.920

1.890 2.150 2.410 2.750

700-600-500 700-600-500

l/h 0,9 1,0

n° 3 + Auto 3 + Auto

43-40-37 43-40-37

52-49-46 52-49-46

230/1/50 230/1/50

0,087 0,087 0,087 0,087

R410A R410A

6,35(1/4") 6,35(1/4")

12,70(1/2") 12,70(1/2")

Kg 16/2,5 16/2,5

mm 296x575x575 296x575x575

mm 41x730x730 41x730x730

PRODUCT NAME ASS36MH ASS45MH

3,60 4,20 4,70 5,20

BTU/h 12.280 14.320 16.020 17.740

3.100 3.610 4.040 4.470

700-600-500 750-630-530

l/h 1,2 2,3

n° 3 + Auto 3 + Auto

43-40-37 44-40-37

52-49-46 53-49-46

230/1/50 230/1/50

0,087 0,087 0,087 0,087

R410A R410A

6,35(1/4") 6,35(1/4")

12,70(1/2") 12,70(1/2")

Kg 16/2,5 18/2,5

mm 296x575x575 296x575x575

mm 41x730x730 41x730x730

PRODUCT NAME ASS56MH

5,60 6,30

BTU/h 19.100 21.480

4.820 5.420

750-630-530

l/h 2,3

n° 3 + Auto

44-40-37

53-49-46

230/1/50

0,087 0,087

R410A

6,35(1/4")

12,70(1/2")

Kg 18/2,5

mm 296x575x575

mm 41x730x730

Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) at 2 m dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor / grille

Net dimension Indoor (H./W./D.)

Net dimension grille (H./W./D.)

Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) at 2 m dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor / grille

Net dimension Indoor (H./W./D.)

Net dimension grille (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) at 2 m dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor / grille

Net dimension Indoor (H./W./D.)

Net dimension grille (H./W./D.)

VR

FV

RF

105www.argoclima.com

ASS 73 - 106 - 140

Four-way cassette indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room

Night set back capability

To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)

“I Feel” feature and temperature sensor indoor the remote control

Dry function

New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion

Horizontal flap swinging or to be set on a fixed position by remote control

Special system to avoid condensate dripping from air outlet ribs

Washable air filter

Integrated pump for condensate discharge

Special anti-dripping system on the four air outlets

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

VR

VR

FF

106 www.argoclima.com

Technical data

ASS 73

ASS 73

ASS 106/140

ASS 106/140

A (mm) B (mm)566856

8201 110

261291

182182

157157

A (mm) B (mm) C (mm) D (mm) E (mm) Weight (kg)2835

124124

308338

PRODUCT NAME ASS73MH

7,30 8,00

BTU/h 24.890 27.280

6.280 6.880

1.140-1.020-840

l/h 3,6

n° 3 + Auto

47-45-41

56-54-50

230/1/50

0,175 0,120

R410A

9,52(3/8")

15,88(5/8")

Kg 22/6

mm 338x860x860

mm 30x860x860

PRODUCT NAME ASS106MH

10,60 11,40

BTU/h 36.150 38.880

9.120 9.800

1.920-1.680-1.320

l/h 4,6

n° 3 + Auto

53-50-46

62-59-55

230/1/50

0,210 0,150

R410A

9,52(3/8")

15,88(5/8")

Kg 27/8

mm 338x1.150x860

mm 30x1.150x860

PRODUCT NAME ASS140MH

14,00 16,00

BTU/h 47.740 54.560

12.040 13.760

1.920-1.680-1.320

l/h 6,3

n° 3 + Auto

53-50-46

62-59-55

230/1/50

0,210 0,150

R410A

9,52(3/8")

15,88(5/8")

Kg 27/8

mm 338x1.150x860

mm 30x1.150x860

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) at 2 m dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor / grille

Net dimension Indoor (H./W./D.)

Net dimension grille (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) at 2 m dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor / grille

Net dimension Indoor (H./W./D.)

Net dimension grille (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) at 2 m dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor / grille

Net dimension Indoor (H./W./D.)

Net dimension grille (H./W./D.)

VR

FV

RF

107www.argoclima.com

Ducted indoor unit with optional two-way discharge plenum, to be matched with Mini Multiset and Multiset V.R.F. DC Inverter

systems

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room

Night set back capability

To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)

“I Feel” feature and temperature sensor indoor the remote control

Dry function

Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm W.C.)

Washable air filter

Integrated pump for condensate discharge

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

ADS 22 - 28 - 36

VR

VR

FF

108 www.argoclima.com

Technical data

PRODUCT NAME ADS22MH

2,20 2,50

BTU/h 7.500 8.520

1.890 2.150

600-510-440

l/h 0,8

mm W.G. 5-7

n° 3 + Auto

54-52-49

45-43-40

230/1/50

0,110 0,110

R410A

6,35(1/4")

12,7(1/2")

mm 200

kg 30

mm 266x926x571

mm 266x926x771

PRODUCT NAME ADS28MH

2,80 3,20

BTU/h 9.550 10.920

2.410 2.750

600-510-440

l/h 0,8

mm W.G. 5-7

n° 3 + Auto

54-52-49

45-43-40

230/1/50

0,110 0,110

R410A

6,35(1/4")

12,7(1/2")

mm 200

kg 30

mm 266x926x571

mm 266x926x771

PRODUCT NAME ADS36MH

3,60 4,20

BTU/h 12.280 14.320

3.100 3.610

600-510-440

l/h 1,5

mm W.G. 5-7

n° 3 + Auto

54-52-49

45-43-40

230/1/50

0,110 0,110

R410A

6,35(1/4")

12,7(1/2")

mm 200

kg 30

mm 266x926x571

mm 266x926x771

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.-m.-l.) m3/hDehumidification

External static pressure (min-max)

Fan speeds

Sound power Indoor (h.m.l.) dB(A)

Sound pressure Indoor (h.-m.-l.) at plenum connection dB(A)

Sound pressure Indoor at ducts exit dB(A) < 20

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Duct diameter of the 2-way discharge plenum (optional)

Net weight Indoor

Net dimension Indoor (H./W./D.)

Net dimension Indoor with plenum (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.-m.-l.) m3/hDehumidification

External static pressure (min-max)

Fan speeds

Sound power Indoor (h.m.l.) dB(A)

Sound pressure Indoor (h.-m.-l.) at plenum connection dB(A)

Sound pressure Indoor at ducts exit dB(A) < 20

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Duct diameter of the 2-way discharge plenum (optional)

Net weight Indoor

Net dimension Indoor (H./W./D.)

Net dimension Indoor with plenum (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.-m.-l.) m3/hDehumidification

External static pressure (min-max)

Fan speeds

Sound power Indoor (h.m.l.) dB(A)

Sound pressure Indoor (h.-m.-l.) at plenum connection dB(A)

Sound pressure Indoor at ducts exit dB(A) < 20

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Duct diameter of the 2-way discharge plenum (optional)

Net weight Indoor

Net dimension Indoor (H./W./D.)

Net dimension Indoor with plenum (H./W./D.)VR

FV

RF

109www.argoclima.com

Ducted indoor unit with optional three-way discharge plenum, to be matched with Mini Multiset and Multiset V.R.F. DC Inverter

systems

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room

Night set back capability

To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)

“I Feel” feature and temperature sensor indoor the remote control

Dry function

Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 7 mm W.C.)

Washable air filter

Integrated pump for condensate discharge

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

ADS 45 - 56 - 64

VR

VR

FF

110 www.argoclima.com

Technical data

PRODUCT NAME AD45MHG

4,70 5,20

BTU/h 16.020 17.740

4.040 4.470

875-600-400

l/h 2,3

mm W.G. 5-7

n° 3 + Auto

54-47-42

45-38-33

230/1/50

0,138 0,138

R410A

6,35(1/4")

12,7(1/2")

mm 200

kg 35

mm 266x1.132x571

mm 266x1.132x771

PRODUCT NAME ADS56MH

5,60 6,30

BTU/h 19.100 21.480

4.820 5.420

875-600-400

l/h 2,3

mm W.G. 5-7

n° 3 + Auto

54-47-42

45-38-33

230/1/50

0,138 0,138

R410A

6,35(1/4")

12,7(1/2")

mm 200

kg 35

mm 266x1.132x571

mm 266x1.132x771

PRODUCT NAME AD64MHG

6,40 7,00

BTU/h 21.850 23.870

5.500 6.020

1000-700-600

l/h 2,6

mm W.G. 5-7

n° 3 + Auto

57-49-46

48-40-37

230/1/50

0,136 0,136

R410A

9,52(3/8")

15,88(5/8")

mm 200

kg 35

mm 266x1.132x571

mm 266x1.132x771

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

External static pressure (min-max)

Fan speeds

Sound power Indoor (h.m.l.) dB(A)

Sound pressure Indoor (h.m.l.) at discharge plenum connection dB(A)

Sound pressure Indoor at ducts exit dB(A) < 20

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Duct diameter of the 3-way discharge plenum (optional)

Net weight Indoor

Net dimension Indoor (H./W./D.)

Net dimension Indoor with plenum (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.-m.-l.) m3/hDehumidification

External static pressure (min-max)

Fan speeds

Sound power Indoor (h.-m.-l.) dB(A)

Sound pressure Indoor (h.-m.-l.) at plenum connection dB(A)

Sound pressure Indoor at ducts exit dB(A) < 20

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Duct diameter of the 3-way discharge plenum (optional)

Net weight Indoor

Net dimension Indoor (H./W./D.)

Net dimension Indoor with plenum (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.-m.-l.) m3/hDehumidification

External static pressure (min-max)

Fan speeds

Sound power Indoor (h.m.l.) dB(A)

Sound pressure Indoor (h.-m.-l.) at plenum connection dB(A)

Sound pressure Indoor at ducts exit dB(A) < 20

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Duct diameter of the 3-way discharge plenum (optional)

Net weight Indoor

Net dimension Indoor (H./W./D.)

Net dimension Indoor with plenum (H./W./D.)VR

FV

RF

111www.argoclima.com

Three/Four way Ducted indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room

Night set back capability

To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)

“I Feel” feature and temperature sensor indoor the remote control

Dry function

Three-speed centrifugal fan by remote control and feature to increase speed/pressure (from 5 to 10 mm W.C.)

Integrated pump for condensate discharge

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

ADS 106 - 140

ADS 73

ADS 73 - 106 - 140

VR

VR

FF

112 www.argoclima.com

Technical data

PRODUCT NAME ADS73MH

7,3 8,0

BTU/h 24.890 27.280

6.280 6.880

1.080-900-780

l/h 3,5

mm W.G. 5,1-9,4

n° 3 + Auto

43-39-36

34-30-27

230/1/50

0,195 0,183

R410A

9,52(3/8")

15,88(5/8")

mm 200

kg 32

mm 310x1.000x630

PRODUCT NAME ADS106MH

10,6 11,4

BTU/h 36.140 38.880

9.120 9.800

1.800-1.560-1.260

l/h 4,2

mm W.G. 8,1-12,4

n° 3 + Auto

47-42-40

38-33-31

230/1/50

0,327 0,315

R410A

9,52(3/8")

15,88(5/8")

mm 200

Kg 47

mm 310x1.480x630

PRODUCT NAME ADS140MH

14,00 16,00

BTU/h 47.740 54.560

12.040 13.760

1.980-1.560-1.320

l/h 6,6

mm W.G. 8-11,5

n° 3 + Auto

49-46-42

40-37-33

230/1/50

0,325 0,313

R410A

9,52(3/8")

15,88(5/8")

mm 200

Kg 47

mm 310x1.480x630

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

External static pressure (min-max)

Fan speeds

Sound power Indoor (h.m.l.) dB(A)

Sound pressure Indoor (h.m.l.) dB(A)

Sound pressure Indoor at ducts exit dB(A) < 20

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Ducts diameter

Net weight Indoor

Net dimension Indoor (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

External static pressure (min-max)

Fan speeds

Sound power Indoor (h.m.l.) dB(A)

Sound pressure Indoor (h.m.l.) dB(A)

Sound pressure Indoor at ducts exit dB(A) < 20

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Ducts diameter

Net weight Indoor

Net dimension Indoor (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

External static pressure (min-max)

Fan speeds

Sound power Indoor (h.m.l.) dB(A)

Sound pressure Indoor (h.m.l.) dB(A)

Sound pressure Indoor at ducts exit dB(A) < 20

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Ducts diameter

Net weight Indoor

Net dimension Indoor (H./W./D.)VR

FV

RF

113www.argoclima.com

Underceiling indoor unit for Mini Multiset and Multiset V.R.F. DC Inverter systems

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room

Night set back capability

To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)

“I Feel” feature and temperature sensor indoor the remote control

Dry function

New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion

Horizontal flap swinging or to be set on a fixed position by remote control

Vertical flap by manual control

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

ACS 73 - 106 - 140

VR

VR

FF

114 www.argoclima.com

Technical data

PRODUCT NAME ACS73MH

7,3 8,0

BTU/h 24.890 27.280

6.280 6.880

1.098-900-840

l/h 3,0

n° 3 + Auto

38-36-33

49-47-44

230/1/50

0,043 0,042

R410A

9,52(3/8")

15,88(5/8")

Kg 25,0

mm 210x1.180x680

PRODUCT NAME ACS106MH

10,6 11,4

BTU/h 36.140 38.880

9.120 9.800

1.650-1.380-1.200

l/h 3,9

n° 3 + Auto

41-38-35

52-49-46

230/1/50

0,074 0,073

R410A

9,52(3/8")

15,88(5/8")

Kg 33

mm 210x1.595x680

PRODUCT NAME ACS140MH

14,00 16,00

BTU/h 47.740 54.560

12.040 13.760

1.800-1.560-1.320

l/h 5,6

n° 3 + Auto

43-40-37

54-51-48

230/1/50

0,086 0,085

R410A

9,52(3/8")

15,88(5/8")

Kg 33,0

mm 210x1.595x680

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

Features Units Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.m.l.) dB(A)

Sound power Indoor (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

VR

FV

RF

115www.argoclima.com

Floor/ceiling indoor unit for Mini Multiset and Multiset V.R.F. DC Inverter systems

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room

Night set back capability

To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)

“I Feel” feature and temperature sensor indoor the remote control

Dry function

New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion

Horizontal flap swinging or to be set on a fixed position by remote control

Vertical flap by manual control

Washable air filter

Optional active carbon filters

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

FC 22 - 28 - 36 - 45 - 56 - 64

VR

VR

FF

116 www.argoclima.com

Technical data

PRODUCT NAME FC22MHG FC28MHG

2,20 2,50 2,80 3,20

BTU/h 7.500 8.520 9.550 10.920

1.890 2.150 2.410 2.750

700-590-500 700-590-500

l/h 1,0 1,2

n° 3 + Auto 3 + Auto

47-43-38 47-43-38

55-51-46 55-51-46

230/1/50 230/1/50

0,065 0,065 0,065 0,065

R410A R410A

6,35(1/4") 6,35(1/4")

12,70(1/2") 12,70(1/2")

Kg 23,5 23,5

mm 680x900x190 680x900x190

PRODUCT NAME FC36MHG FC45MHG

3,60 4,20 4,70 5,20

BTU/h 12.280 14.320 16.020 17.740

3.100 3.610 4.040 4.470

700-590-500 830-760-665

l/h 1,3 2,3

n° 3 + Auto 3 + Auto

47-43-38 52-49-46

55-51-46 60-57-54

230/1/50 230/1/50

0,065 0,065 0,088 0,088

R410A R410A

6,35(1/4") 6,35(1/4")

12,70(1/2") 12,70(1/2")

Kg 23,5 23,5

mm 680x900x190 680x900x190

PRODUCT NAME FC56MHG FC64MHG

5,60 6,30 6,40 7,00

BTU/h 19.100 21.480 21.850 23.870

4.820 5.420 5.500 6.020

830-760-665 830-760-665

l/h 2,3 2,3

n° 3 + Auto 3 + Auto

52-49-46 52-49-46

60-57-54 60-57-54

230/1/50 230/1/50

0,088 0,088 0,088 0,088

R410A R410A

6,35(1/4") 9,52(3/8")

12,70(1/2") 15,88(5/8")

Kg 23,5 23,5

mm 680x900x190 680x900x190

Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.-m.-l.) at 2m dB(A)

Sound power Indoor (h.-m.-l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.-m.-l.) at 2m dB(A)

Sound power Indoor (h.-m.-l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.-m.-l.) at 2m dB(A)

Sound power Indoor (h.-m.-l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

VR

FV

RF

117www.argoclima.com

Slim ducted indoor unit, available for floor or wall or ceiling installation, to be matched with Mini Multiset and Multiset V.R.F. DC Inverter

systems

Especially projected for hotel applications

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room

Night set back capability

To be managed by the wired and wireless controllers of the Multiset V.R.F. DC Inverter systems (all optional)

“I Feel” feature and temperature sensor indoor the remote control

Dry function

New three-speed centrifugal fan by remote control, granting a better and low noise air diffusion

Washable air filter

Optional active carbon filters

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

SD 22 - 28 - 36 - 45 - 56 - 64

VR

VR

FF

118 www.argoclima.com

Technical data

PRODUCT NAME SD22MHG SD28MHG

2,20 2,50 2,80 3,20

BTU/h 7.500 8.520 9.550 10.920

1.890 2.150 2.410 2.750

470-380-340 470-380-340

l/h 1,0 1,2

n° 3 + Auto 3 + Auto

37-30-26 37-30-26

45-38-34 45-38-34

230/1/50 230/1/50

0,037 0,037 0,037 0,037

R410A R410A

6,35(1/4") 6,35(1/4")

12,70(1/2") 12,70(1/2")

Kg 25 25

mm 585x890x190 585x890x190

PRODUCT NAME SD36MHG SD45MHG

3,60 4,20 4,70 5,20

BTU/h 12.280 14.320 16.020 17.740

3.100 3.610 4.040 4.470

470-380-340 620-540-450

l/h 1,3 2,3

n° 3 + Auto 3 + Auto

37-30-26 45-41-33

45-38-34 53-49-41

230/1/50 230/1/50

0,037 0,037 0,065 0,065

R410A R410A

6,35(1/4") 6,35(1/4")

12,70(1/2") 12,70(1/2")

Kg 25 25

mm 585x890x190 585x890x190

PRODUCT NAME SD56MHG SD64MHG

5,60 6,30 6,40 7,00

BTU/h 19.100 21.480 21.850 23.870

4.820 5.420 5.500 6.020

620-540-450 680-600-520

l/h 2,3 3,3

n° 3 + Auto 3 + Auto

45-41-33 49-45-40

53-49-41 57-53-48

230/1/50 230/1/50

0,065 0,065 0,088 0,088

R410A R410A

6,35(1/4") 9,52(3/8")

12,70(1/2") 15,88(5/8")

Kg 25 25

mm 585x890x190 585x890x190

Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.-m.-l.) at 2m dB(A)

Sound power Indoor (h.-m.-l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.-m.-l.) at 2m dB(A)

Sound power Indoor (h.-m.-l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

Features Units Cooling Heating Cooling Heating

Cooling/Heating capacity

kW

kcal/h

Air flowrate Indoor (h.m.l.) m3/hDehumidification

Fan speeds

Sound pressure Indoor (h.-m.-l.) at 2m dB(A)

Sound power Indoor (h.-m.-l.) dB(A)

Power supply V/Ph/Hz

Running consumption kW

Refrigerant type

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight Indoor

Net dimension Indoor (H./W./D.)

VR

FV

RF

119www.argoclima.com

Ducted indoor unit to be matched with Mini Multiset and Multiset V.R.F. DC Inverter systems

High static pressure, low noise

Easy placement in any type of environment

Automatic change-over between cooling and heating modes

Special function during heat pump start-up and defrosting cycle to avoid cool air emission in the room

Night set back capability

To be managed by wired and wireless controllers of Multiset V.R.F. DC Inverter systems (all optional)

“I Feel” feature and temperature sensor indoor the remote control

Dry function

Dynamic refrigerant control by DC Inverter compressor and circuit, electronic valve and fuzzy logic managed by a powerful

microprocessor

Valve Kit to prevent gas accumulation: with the exception of mono systems, it takes 2 valves each unit of models 224 and 280 if

connected to the same outdoor unit in a multi-system

ADPS 140 ADPS 224 - 280

ADPS 140 - 224 - 280

VR

VR

FF

120 www.argoclima.com

Technical data

PRODUCT NAME ADPS140MH

14,0 16,02160/2100/1980

167n° 3 + Auto

47/46/4458/57/55230/1/50

0,60/0,66/0,71 0,60/0,66/0,71A 2,80/2,90/3,00 2,80/2,90/3,00

9,52(3/8")15,88(5/8")

Kg 54mm 450/1065/620

Features Units Cooling HeatingCooling/Heating capacity kWAir flowrate (h.m.l.) mExternal static pressure (max) PaFan speeds Sound power (h.m.l.) dB(A)Sound pressure (h.m.l.) dB(A)Power supply V/Ph/HzRunning consumption (min.-med.-max.) kWRunning current (min.-med.-max.)Liquid pipe diameter mm(inch")Gas pipe diameter mm(inch")Net weightNet dimensions (H./W./D.)

PRODUCT NAME ADPS224MH

22,4 25

3360/3190/2980

176

n° 3 + Auto

48/47/46

59/58/57

230/1/50

0,87/0,90/0,93 0,87/0,90/0,93

A 4,50/4,06/4,07 4,05/4,06/4,07

9,52(3/8")

19,05(3/4")

Kg 110

mm 467/1428/1230

Features Units Cooling Heating

Cooling/Heating capacity kW

Air flowrate (h.m.l.) m

External static pressure (max) Pa

Fan speeds

Sound power (h.m.l.) dB(A)

Sound pressure (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption (min.-med.-max.) kW

Running current (min.-med.-max.)

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight

Net dimensions (H./W./D.)

PRODUCT NAME ADPS280MH

28,0 31,50

4320/4200/3960

216

n° 3 + Auto

51/50/49

62/61/60

230/1/50

1,27/1,33/1,39 1,27/1,33/1,39

A 6,04/6,06/6,07 6,04/6,06/6,07

9,52(3/8")

22,22 (7/8")

Kg 120

mm 467/1428/1230

Features Units Cooling Heating

Cooling/Heating capacity kW

Air flowrate (h.m.l.) m

External static pressure (max) Pa

Fan speeds

Sound power (h.m.l.) dB(A)

Sound pressure (h.m.l.) dB(A)

Power supply V/Ph/Hz

Running consumption (min.-med.-max.) kW

Running current (min.-med.-max.)

Liquid pipe diameter mm(inch")

Gas pipe diameter mm(inch")

Net weight

Net dimensions (H./W./D.)

VR

FV

RF

121www.argoclima.com

Controlli controls and accessories

Schedule timer able to manage up to 64

indoor units with customized programming of

all features, on/off cycles, etc.

System controller to be used to manage only

on/off cycles for a system up to 16 groups /

64 indoor units, to be used in matching with

other controllers (remote controllers, system

controllers, etc.)

System controller to be used to manage and

program a system up to 16 groups / 64 indoor

units, with or without remote controllers; it can

be matched with schedule timer and intelli-

gent controller

Interface PLC for outdoor units: can control

up to 4 outdoor units. Required for “Demand”

control, typical of 3-way systems

New standard wired remote controller

equipped with weekly timer,caracterized by full

features control, selfdiagnostic and centralized

programming capabilities.

New Touch Screen Intelligent Controller for

WEB: to be used to manage and program

a system up to 256 indoor units, organized

in 4 groups of 64 units each, also without

wired controllers; it can be matched with

the schedule timer and in case of three/four-

group installations it must be connected with

the communication adapter on the outdoor

unit. User friendly touch screen operation.

Web browser: it allows to control VRF system

by its own PC at home using an Internet

connection with a LAN cable.

Infrared remote controller to be used with

high-wall indoor units

Infrared remote controller to be used with

cassette and floor/ceiling indoor units

Infrared remote controller to be used with

underceiling indoor units

Infrared remote controller to be used, in

matching with a special infrared receiver,

with the full range of indoor units; it shows

the operation status of the air-conditioner

Standard wired remote controller with full

features control, self-diagnostic and

centralized programming capabilities

Simplified wired remote controller to be

used with the full range of indoor units; it

controls all the main features

Remote sensor to be used with the full

range of indoor units to detect the room

temperature when no remote controller

sensor or body sensor is used: suggested

for air-conditioner systems without remote

controller

VR

VR

FF

122 www.argoclima.com

Multiset v.r.f. controls functions

TIMER

Picture

Description Standard wiredControl

Standard wiredControl + Timer

Simplified wiredControl

Infrared remoteControl

WeeklyTimer

REM HW standard REM HW TM REM HWS REM HL REM HW T

-

17 / 27 °C 17 / 27 °C 17 / 27 °C 17 / 27 °C-

16 / 26 °C 16 / 26 °C 16 / 26 °C 16 / 26 °C-

18 / 30 °C 18 / 30 °C 18 / 30 °C 18 / 30 °C-

18 / 30 °C 18 / 30 °C 18 / 30 °C 18 / 30 °C-

3 + auto 3 + auto 3 + auto 3 + auto-

temperaure +/- temperature +/- temperature +/- temperature +/--

flap flap flap flap-

timer 72 weekly timer-

timer 72 h weekly timer

sensor t.(2) sensor t.(2) sensor t.(2) sensor t.(2)

Interdiction to use indoor unit

control functions

Fault alarm Fault alarm Fault alarm--

Dirty filter Dirty filter Dirty filter--

N° of units controlled max. 8 max. 8 max. 8 max. 8

1 group with 64 units 8 groups with 8 units

4 groups with 16 units

It works only with a secondary control

It works only with a secondary control

It works only with a secondary control

It works only with a secondary control

6 daily programs x 7 days + holiday

You can select 6 different addresses

Power supplyby REM HW-64 S

or T10-PCBindoor unit connector

Oth

erFu

nctio

ns

INDIVIDUALS CONTROLS

Model

VR

FV

RF

123www.argoclima.com

Multiset v.r.f. controls functions

Picture

Description System control ON/OFFSystem control

Intelligent touch controller

Adapter for control system

LonWorksInterface

PLCInterface

REM HW 64S REM HW 16S REM HW 256S REM HWAS LWI IEM

-

17 / 27 °C-

17 / 27 °C-

17 / 27 °C 17 / 27 °C

16 / 26 °C-

16 / 26 °C-

16 / 26 °C 16 / 26 °C

18 / 30 °C-

18 / 30 °C-

18 / 30 °C 18 / 30 °C

18 / 30 °C-

18 / 30 °C-

18 / 30 °C 18 / 30 °C

3 + auto-

3 + auto-

3 + auto 3 + auto

temperature +/--

temperature +/--

temperature +/- temperature +/-

flap-

flap-

palfpalf

--timer

---

Interdiction to use indoor unit control

functions

Interdiction to use indoor unit control

functions- ---

Malfunctions report-

Fault alarm Fault alarm- -

Dirty filter-----

N° of units controlled

16 groups of 4 units(max 64 units)

16 groups of 4 units(max 64 units)

64 units x 4 systemsmax 256 indoor units30 units x 4 systems

max 120 outdoor units

2 systems, 64 units x 2 max 128 units

16 groups of 4 units(max 64 units)

16 groups of 4 units(max 64 units)

Over 3 systemsyou must use

REMHWAS (max 7)

to use withREMHW256S(+3 systems)

You must use the individual controls

Monitoring and calculation of

consumption distribution

GROUP CONTROLS

The control central canperform functions of remote control and

system control, Intelligent Controller

Oth

erFu

nctio

ns

Model

VR

VR

FF

124 www.argoclima.com

REC 03/06/10/14/19/25/30/40

REC heat recovery units, characterized by small size and easy to install, are suitable for residential and commercial applications

Regulations require forced ventilation in realizing air conditioning and air treatment systems, with expulsion of air treated

and consequent increase in energy consumption and costs.

In all these cases REC heat recovery units allow over 50% of energy saving and ensure an adequate environmental comfort

through the use of a static heat exchanger made of aluminium.

REC heat recovery units are available in 8 sizes with airflows from 300 to 4000 m3 /h and high static pressure.

They work both in the summer and in winter.

Particularly suitable for false ceiling installation, they may be appropriately ducted allowing air supply and air suction directly

in the room.

High efficiency aluminium plated heat recovery, with airflows separated by special seals.

The side panels are fully removable, made of double-layer plate with thermal and sound insulation in polyethylene / polyester

with an average thickness of 10 mm for models REC 03-06-10 and 20mm for the other models.

In the lower part of the recovery unit is installed a condensate tank in stainless steel, with drain downward.

The fan group consists of 2 centrifugal fans with double inlet (for the REC 03 model single inlet) separated, one for the recovery

fresh air, the other for the exhaust air.

Single-phase electric motors (3-phase only for REC 40), 2 or 3 speeds.

The fans are mounted on anti-vibration easy removable support, which ensures a very low noise even at maximum speed.

They are also equipped with air filters with performance class G3, easily removable from each side of the unit and regenerate.

REC heat recovery units are available also in vertical version.

MAIN ACCESSORIES

VR

FV

RF

125www.argoclima.com

MODELLOMODEL 03 06 10 14 19 25 30 40

A mm 990 990 1150 1350 1450 1700 1700 1700 B mm 750 750 860 900 900 1230 1230 1230C mm 270 270 385 410 470 490 530 630D mm - - 230 230 280 305 305 405L mm 162 162 240 240 240 306 339 339 H mm 100 100 218 270 270 270 297 297 L1 mm 275 275 330 337 337 502 502 502H1 mm 153 153 267 267 327 347 387 487E mm 195 195 245 241 241 323 308 308 E1 mm 195 195 205 241 241 323 345 345F mm 170 170 238 224 284 290 331 377 G mm 197 197 225 241 241 323 323 323

½” ½” ½” ½” ½“ ½“ ½“ ½“kg 39 41 68 91 99 140 155 179

TYPE AOUTSIDE INSIDE

Fresh air

Exhaust air Supply air

Return air A90 R90

E90 M90

VR

VR

FF

126 www.argoclima.com

MODELS REC 03 REC 06 REC 10 REC 14

Max 300 500 1000 1400200 300 900 1250100 150 800 850

Max 100 100 90 145160 129 70 133167 127 47 113

Max 51,1 51,1 52,2 62,3

49,7 47,4 48,8 56,9

44,3 41,0 45,3 45,6Max

%52,0 56,1 53,4 52,157,0 62,5 54,8 53,566,4 71,1 56,3 58,4

Max 1,4 2,6 4,9 6,71,0 1,7 4,5 6,10,6 1,0 4,1 4,5

Max

°C

8,0 9,0 8,4 8,0

9,3 10,6 8,7 8,4

11,6 12,8 9,1 9,6

FAN

W 2x60 2x60 2x147 2x350

A 1,2 1,4 3 5,8

n° 3 3 3 3

n° 2 2 4 4

IP 20

B

230/1/50

DIMENSIONS / WEIGHT - REC

mm 990/750/270 990/750/270 1150/860/385 1350/900/410

Kg 39 41 68 91

Airflow rate m3/hMedMin

External static pressure PaMedMin

1 m sound pressure level dB (A)Med

Min

Recovery efficiency(1) MedMin

Saved power(1) kWMedMin

Supply temperature(1) Med

Min

Shaft power

Maximum current

Fan speeds

Poles

Protection degree - minimum

Temperature class - minimum

Power supply V/ph/Hz

Width/Length/Height

Net weight

(1) At the following conditions: room air temperature 20°C DB 50% R.H.; fresh air temperature -5°C.

MODELS REC 19 REC 25 REC 30 REC 40

Max 1900 2500 3200 40001570 1830 2500 -1340 1100 1800 3000

Max 120 110 170 170121 112 159 -119 112 144 147

Max 58,4 56,0 58,8 62,1

53,7 51,0 53,5 -

42,1 44,6 51,1 54,9Max

%51,8 57,6 56,0 55,754,1 61,5 59,0 -56,1 67,7 63,1 59,2

Max 9,0 13,2 16,4 20,37,8 10,3 13,5 -6,9 8,6 10,4 16,2

Max

°C

7,9 9,4 9,0 8,9

8,5 10,4 9,8 -

9,0 11,9 10,8 9,8

FAN

W 2x350 2x350 2x550 2x750

A 6,2 6 11,4 6,2

n° 3 3 3 2

n° 4 4 4 4

IP 20

B

230/1/50 400/3/50

DIMENSIONS / WEIGHT - REC

mm 1450/900/470 1700/1230/490 1700/1230/530 1700/1230/630

Kg 99 140 155 179

Airflow rate m3/hMedMin

External static pressure PaMedMin

1 m sound pressure level dB (A)Med

Min

Recovery efficiency(1) MedMin

Saved power(1) kWMedMin

Supply temperature(1) Med

Min

Shaft power

Maximum current

Fan speeds

Poles

Protection degree - minimum

Temperature class - minimum

Power supply V/ph/Hz

Width/Length/Height

Net weight

(1) At the following conditions: room air temperature 20°C DB 50% R.H.; fresh air temperature -5°C.

VR

FV

RF

127www.argoclima.com

Notes:

VR

VR

FF

128 www.argoclima.com

Notes:

VR

FV

RF

129www.argoclima.com

Notes:

VR

VR

FF

www.argoclima.com130 www.argoclima.com

Notes:

VR

FV

RF

131

Regulations on energy efficiency labelling

Argo air conditioners are compliant with the most recent European Standards for the reduction of energy consumption and atmospheric

pollution. The labels that indicate the energy efficiency class were introduced with European Community directive 2002/31/EC, which

makes reference to standard EN14511, which in turn provides precise reference tables for the energy efficiency class classification. Energy

efficiency labels are applied to products (air conditioners with a cooling power of up to 12 kW) on display at retail outlets. They are provided

to inform customers of the efficiency of the product they intend to purchase. The label is divided into two parts, a generic coloured label

and an adhesive black and white label that must be applied over the coloured one.

Our company provides both the labels mentioned above. The generic label is supplied directly at retail outlets, whilst the specific one is

placed inside the packaging of each air conditioner sold. In the event that the specific label has been lost, each retail outlet should be able

to provide another immediately by downloading it from the Internet or requesting it from our marketing dept.

The energy efficiency label indicates the energy class; class A is the highest and is awarded based on tables that compare thermal efficiency

and energy consumption. The indicators of the above ratio are known as: E.E.R. = Energy Efficiency Ratio: this is the ratio between cooling

power (in kw) and power consumption in cooling mode (in kw). C.O.P. = coefficient of performance: this is the ratio between heating power

(in kw) and power consumption in heating mode (in kw).

1) generic - coloured 2) specific - black/white

Example of an energy efficiency label:

The manufacturing company doesn’t assume any responsibility for mistakes

or omissions contained in this catalogue and reserves the right to make at

any time, even without notice, any change considered suitable for technical

or commercial purposes to its products.

headquarter

Via Varese, 90

21013 Gallarate (VA) ITALY

Tel: + 39 0331 755111

Fax: + 39 0331 776240

www.argoclima.com

www.a rgoc l ima .com

Argo is a brand of , European leader in Air Conditioning, Heating and Air Treatment.

7020

1220

1 - 0

3/20

12or

ango

tow

n.co

m