Air Conditioning Applications...type air conditioner, multi-split type conditioner, central air...

4
THINKING SENSOR Air Conditioning Applications Temperature sensors for air conditioning applications are customizable in accordance with temperature detection points, indoor and outdoor environments, temperature operation range, etc, THINKING temperature sensors for air conditioning applications meet customer’s needs for temperature response time and operate in humid and foul environment with dramatic temperature change. Floor standing type air conditioner, single-split type air conditioner, multi-split type conditioner, central air conditioning and heating system, cabinet air conditioner, etc. Ambient Temperature Detection: temperature sensors are usually installed in heat sinks of indoor and outdoor units, and remote controller. Temperature Detection of Copper Tube: detection points vary with models of air conditioners, and detection points can be fan coil in indoor and outdoor units, exhaust pipe of compressor, low pressure pipe, etc. Water Temperature Detection: temperature detection of cold water and hot water in central air conditioning and heating system. Temperature Sensor Air Conditioning Applications Your Best Choice 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Feature Function Application

Transcript of Air Conditioning Applications...type air conditioner, multi-split type conditioner, central air...

Page 1: Air Conditioning Applications...type air conditioner, multi-split type conditioner, central air conditioning and heating system, cabinet air conditioner, etc. Ambient Temperature Detection:

THINKINGSENSOR

Air

Con

ditio

ning

App

licat

ions

◆ Temperature sensors for air conditioning applications are customizable in accordance with temperature detection points, indoor and outdoor environments, temperature operation range, etc,

◆THINKING temperature sensors for air conditioning applications meet customer’s needs for temperature response time and operate in humid and foul environment with dramatic temperature change.

Floor standing type air conditioner, single-split type air conditioner, multi-split type conditioner, central air conditioning and heating system, cabinet air conditioner, etc.

◆Ambient Temperature Detection: temperature sensors are usually installed in heat sinks of indoor and outdoor units, and remote controller.

◆Temperature Detection of Copper Tube: detection points vary with models of air conditioners, and detection points can be fan coil in indoor and outdoor units, exhaust pipe of compressor, low pressure pipe, etc.

◆Water Temperature Detection: temperature detection of cold water and hot water in central air conditioning and heating system.

Temperature Sensor

Air Conditioning ApplicationsYour Best Choice

1

2

3 4

5

6

7

8

9

10

11 12 13

14

15

16

Feature

Function

ApplicationHEADQUARTER 12F, No.93, Dashun 1st Rd., Zuoying Dist., Kaohsiung, Taiwan 81357 / Tel: 886-7-5577660

TAIPEI, TAIWAN 3F, No.25, Lane 70, Wugong 2nd Rd., Xinzhuang Dist., New Taipei City, Taiwan 24888 / Tel: 886-2-22990652

JIANGSU, CHINA No.6, Longmen Rd., Wujin High & New-Tech Industrial Development Zone, Changzhou, Jiangsu, China 213161 / Tel: 86-519-86578999

GUANGDONG, CHINA No.45, East Rd., Sha-Tao Dist., Chang-An Town, Dongguan City, Guangdong, China 523863 / Tel: 86-769-85542016

BEIJING, CHINA Room 2707, Building 1, No. 88, Jian Guo Road, Chaoyang Dist., Beijing City, China 100025 / Tel: 86-010-85898940

QINGDAO, CHINA No.696, Hefei Rd., Shibei Dist., Qingdao City, China 266035 / Tel: 86-138-08993369/86-186-69738999

HUBEI, CHINA California Sunshine Community, Guanggu Rd. Donghu New Technical Development Zone, Wuhan City, Hubei, China / Tel: 86-189-95621889

Page 2: Air Conditioning Applications...type air conditioner, multi-split type conditioner, central air conditioning and heating system, cabinet air conditioner, etc. Ambient Temperature Detection:

THINKING SENSOR

Screw-On Type

Epoxy Coating

Type

Metal CaseType

Feature: Screw-on design is for easy installationApplication: The product is installed on metallic surface for temperature detection,

and is generally installed in compressor or collant.

Feature: Epoxy coated sensing top is a simple design and resistant to humidity, and the sensor usually detects air temperature directly.

Application: The product is generally installed in evaporator of indoor unit to detect temperature.

Feature: Material of metal case is the same as that of detected object for more accurate temperature detection and increase of product stability.

Application: The product detects temperatures of fan coil in indoor and outdoor units, exhaust pipe of compressor, and low pressure pipe. Temperature sensor made of stainless-steel material is suitable for above-mentioned applications, and can be installed in inlet and outlet pipes of centrial air conditioning system for water temperature detection.

Component|Sensing top (terminal+NTC chip+epoxy)+lead wireMoisture Resistance|40℃ 95% RH X 1000 hoursOperation Temperature|-30~+125℃Insulation Test|DC 500V 100MΩ(Min)R Value|R25℃=210KΩ±3% B Value|B25/50=3950K±1%Thermal Time Constant|Around 20 seconds Hi-Pot Test|AC 1500V 10mA(Max)

Component|Terminal+NTC chip in plastic caseMoisture Resistance|40℃ 95% RH X 1000 hours Operation Temperature|-40~+105℃ Insulation Test|DC 500V 100MΩ(Min)R Value|R25℃=10KΩ±1% B Value|B25/85=3435K±1%Thermal Time Constant|Around 20 seconds (heating plate) Hi-Pot Test| AC 1500V 10mA(Max)

Component|Sensing top (terminal+NTC chip+epoxy)+lead wire+tube +terminal+housingMoisture Resistance|40℃ 95% RH X 1000 hours Operation Temperature|-20~+105℃ Insulation Test|DC 500V 100MΩ(Min)R Value|R25℃=10KΩ±5% B Value|B25/50=3950K±2%Thermal Time Constant|Around 20 seconds (heating plate) Hi-Pot Test| AC 1500V 10mA (Max)

Component|Sensing top (NTC chip+epoxy)+lead wire+terminal +housingMoisture Resistance|40℃ 95 % RH X 1000 hours Operation Temperature|-20~+105℃ Insulation Test|DC 500V 100MΩ(Min)R Value|R25℃=10KΩ±2% B Value|B25/50=3950K±2%Thermal Time Constant|Around 5 seconds (in water)

Component|Sensing top (NTC chip+epoxy)+lead wire Moisture Resistance|40℃ 95 % RH X 1000 hoursOperation Temperature|-30~+105℃ Insulation Test|DC 500V 100MΩ(Min)R Value|R25℃=10KΩ±1% B Value|B25/50=3450K±1%Thermal Time Constant|Around 5 seconds (in water)

Component|Sensing top (NTC chip+copper cap)+lead wire+tube +terminal+housingMoisture Resistance|40℃ 95 % RH X 1000 hoursOperation Temperature|-30~+125℃ Insulation Test|DC 500V 100MΩ (Min)R Value|R110℃=1.28KΩ±5% B Value|B100/110=4400K±3%Thermal Time Constant|Around 10 seconds (in water) Hi-Pot Test| AC 1500V 10mA (Max)

Max 10

Max

3.5

250 ± 5

4.5± 1

0.5±0.03

2000±40 18+0/ - 1

Φ 3.15± 0.15

7.1

±0.

2

6.4±0.3 4±130±10

Page 3: Air Conditioning Applications...type air conditioner, multi-split type conditioner, central air conditioning and heating system, cabinet air conditioner, etc. Ambient Temperature Detection:

Thinking Electronic Industrial Co., Ltd.

1. Temperature sensor is customizable in accordance with customer’s needs, and THINKING provides consulting services for sensor design.

2. All specifications are subject to change without notice.

3. Please contact your sales representative if you have any questions.

Plastic CaseType

Component|Sensing top (terminal+NTC chip+epoxy)+lead wire+tube +terminal+housingMoisture Resistance|40℃ 95% RH X 1000 hours Operation Temperature|-20~+105℃ Insulation Test|DC 500V 100MΩ(Min)R Value|R25℃=10KΩ±5% B Value|B25/50=3950K±2%Thermal Time Constant|Around 20 seconds (heating plate) Hi-Pot Test| AC 1500V 10mA (Max)

Feature: Plastic sensing top is encapsulated with insulation glue, and the sensor is hihgly resistant to water and corrosion.

Application: The product detects not only water temperature of central air conditioning and heating system but also indoor and outdoor ambient temperature.

Component|Sensing top (NTC chip+plastic case)+lead wire+tube +forming+terminal+housingMoisture Resistance|40℃ 95 % RH X 1000 hours Operation Temperature|-40~+105℃ Insulation Test|DC 500V 100MΩ (Min)R Value|R25℃=2.7 KΩ±3% B Value|B25/50=3860 K±1%Thermal Time Constant|Around 20 seconds (in water)Hi-Pot Test| AC 1500V 10mA (Max)Component|Sensing top (NTC chip+plastic case)+lead wire+terminal +housingMoisture Resistance|40℃ 95 % RH X 1000 hoursOperation Temperature|-40~+105℃ Insulation Test|DC 500V 100MΩ (Min)R Value|R25℃=10KΩ±5% B Value|B25/50= 3935K±1%Thermal Time Constant|Around 20 seconds (in water)Hi-Pot Test| AC 1500V 10mA (Max)

Component|Sensing top (NTC chip+brass cap+clip)+lead wire +terminal+housingMoisture Resistance|40℃ 95% RH X 1000 hoursOperation Temperature|-30~+105℃ Insulation Test|DC 500V 100MΩ (Min)R Value|R25℃=30 KΩ±3% B Value|B25/50=3900 K±2%Thermal Time Constant|Around 10 seconds (in water) Hi-Pot Test|AC 1500V 10mA (Max)

Component|Sensing top (NTC chip+stainless steel case)+terminal +housingMoisture Resistance|40℃ 95% RH X 1000 hoursOperation Temperature|0~+105℃ Insulation Test|DC 500V 100MΩ (Min)R Value|R25℃=10 KΩ±1% B Value|B25/85=3435K±1%Thermal Time Constant|Around 10 seconds (in water) Hi-Pot Test| AC 1500V 10mA (Max)Component|Sensing top (NTC chip+stainless steel case)+lead wireMoisture Resistance|40℃ 95% RH X 1000 hoursOperation Temperature|-20~+80℃ Insulation Test|DC 500V 100MΩ(Min)R Value|R25℃=10 KΩ±1% B Value|B25/85=3435K±1%Thermal Time Constant|Around 10 seconds (in water)Hi-Pot Test| AC 1500V 10mA (Max)

Component|Sensing top (NTC chip+stainless steel case)+tube +lead wireMoisture Resistance|40℃ 95% RH X 1000 hours Operation Temperature|-20~+105℃ Insulation Test|DC 500V 100MΩ(Min)R Value|R25℃=10 KΩ±1% B Value|B25/85=3435K±1%Thermal Time Constant|Around 90 seconds (in air) Hi-Pot Test| AC 1500V 10mA (Max)

12.7±0.5 9.9±0.3 14.3±0.3 9.5±0.4

Φ4.

0±0.

2

15.8±0.3

9144±100

5±130±5

15±5

85±5

25±560±5

6.35±0.05

120±

5

Φ4.

0±0.

3

7620±10092.2±5

70±2 22.2±2

3.2±0.3

Φ10

.1±0.

3

Φ6.

4±0.

3

38±5

6±2

Φ5.

0±0.

2

1600±25

24±1 30±53±1

Page 4: Air Conditioning Applications...type air conditioner, multi-split type conditioner, central air conditioning and heating system, cabinet air conditioner, etc. Ambient Temperature Detection:

Temperature detection of indoor environment

Temperature detection of outdoor environment

Temperature detection of fan coil in indoor unit

Temperature detection of evaporation in indoor unit

Detection of low pressure pipe in outdoor unit

Temperature detection of exhaust pipe of compressor in outdoor unit

Temperature detection of fan coil in outdoor Unit

THINKING SENSOR

www.thinking.com.tw

Multiple Sensor

Structure

Feature: Sensor is with various sensing tops and electrical characteristics for circuit design and assembly.

Application: The sensor is generally installed in split type air conditioner, indoor unit, and outdoor unit, and is designed based on customer’s needs.

Component|Sensing top (NTC chip+epoxy,NTC chip+copper cap) +lead wire+tube+tie+terminal+housingMoisture Resistance|40℃ 95% RH X 1000 hoursOperation Temperature|-40~+105℃ Insulation Test|DC 500V 100MΩ(Min)R Value|TH1/TH3 : R25=10KΩ±2% B Value|TH1/TH3:B25/85=3435K±1% TH2 :R25=50KΩ±3% TH2:B25/85=3992K±1%Thermal Time Constant|Around 15 seconds (in water) Component|Sensing top (NTC chip+copper cap)+lead wire+tube +tie+terminal+housingMoisture Resistance|40℃ 95% RH X 1000 hours Operation Temperature|-30~+105℃ Insulation Test|DC 500V 100MΩ(Min)R Value|TH1:R25℃=10KΩ±3% B Value|TH1:B25/50=3950K±2% TH2:R0℃=5.9KΩ±3% TH2:B0/25=3400K±1%Thermal Time Constant|Around 15 seconds (in water)

Component|Sensing top (NTC chip+epoxy, NTC chip+copper cap) +lead wire+tube+tie++terminal+housingMoisture Resistance|40℃ 95% RH X 1000 hours Operation Temperature|-40~+105℃ Insulation Test|DC 500V 100MΩ(Min)R Value|R0℃=15 KOhm±2% B Value| B0/100=3450 K±2%Thermal Time Constant|Around 15 seconds (in water)

Component|Sensing top(NTC chip+copper cap)+lead wire+tube+tie +terminal+housingMoisture Resistance|40℃ 95% RH X 1000 hoursOperation Temperature|-20~+80℃ Insulation Test|DC 500V 100MΩ(Min)R Value|R25℃=2KΩ±5% B Value|B25/50=3500K±2%Thermal Time Constant|Around 15 seconds (in water) Hi-Pot Test| AC 1500V 10mA(Max)

TH3

20

5.0

Φ

TH1

TH2

15

500±10

310±10350±10

660±10700±1525±1

6±0.

3

500±15

Φ6±

0.1

TH4

TH3

TH1Max10

Max10

Max10

Max10

TH2

520

415

435

325

130±10

355±10

250±10

270±10

160±10

30±1

750

30±1

30±1

700

890840

TH1

TH2

640±20

Φ6±

0.1

Φ6±

0.1

TH1

TH2

30±1

Φ6±

0.1 410±10

460±10

20

Product Application

HEADQUARTER 12F, No.93, Dashun 1st Rd., Zuoying Dist., Kaohsiung, Taiwan 81357 / Tel: 886-7-5577660

TAIPEI, TAIWAN 3F, No.25, Lane 70, Wugong 2nd Rd., Xinzhuang Dist., New Taipei City, Taiwan 24888 / Tel: 886-2-22990652

JIANGSU, CHINA No.6, Longmen Rd., Wujin High & New-Tech Industrial Development Zone, Changzhou, Jiangsu, China 213161 / Tel: 86-519-86578999

GUANGDONG, CHINA No.45, East Rd., Sha-Tao Dist., Chang-An Town, Dongguan City, Guangdong, China 523863 / Tel: 86-769-85542016

BEIJING, CHINA Room 2707, Building 1, No. 88, Jian Guo Road, Chaoyang Dist., Beijing City, China 100025 / Tel: 86-010-85898940

QINGDAO, CHINA No.696, Hefei Rd., Shibei Dist., Qingdao City, China 266035 / Tel: 86-138-08993369/86-186-69738999

HUBEI, CHINA California Sunshine Community, Guanggu Rd. Donghu New Technical Development Zone, Wuhan City, Hubei, China / Tel: 86-189-95621889