ARDOCELL PQ, PL Pyrometer Series · Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 2...
Transcript of ARDOCELL PQ, PL Pyrometer Series · Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 2...
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 2
Probedruck
C M Y CM MY CY CMY K
ARDOCELL PQ, PL Pyrometer SeriesQuick and exact non-contact temperature measurementfrom -30 °C to +2500 °C.
Industrial Technologies
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 3
Probedruck
C M Y CM MY CY CMY K
Features that make ARDOCELLPQ and PL Pyrometers superior
General� For temperatures ranging from
–30 °C to +2500 °C� Both wide measuring range and high tem-
perature resolution� Digital signal processing� Based on light sensor technology; no me-
chanical moving parts� Nonwearing� No maintenance
Optics� Excellent optical characteristics due to the
precision lens (non-hygroscopic) with broadband antireflection coating
� Various distance ratios� Customised focus adjustment
(ARDOCELL PQ)� Smallest target diameter 0.66 mm� Focusable optics for accurate distance ad-
justment (ARDOCELL PL)
Electronics� High accuracy due to digital signal
processing� Very short response time� Very wide measuring ranges� Immune to electromagnetic interference
Signal Outputs� Analogue output 0(4) to 20 mA, linear,
switchable� USB interface via VK 11/C-USB PC connec-
tion box.
2
Display� Bright, easy to read LED display� Digit height 8 mm� Data readable from a distance of
up to 5 m
Mechanical Construction� Rugged stainless steel housing� Compact design� Electrical connection via plug� Rated IP 65� Optional: encapsulated housing
for use in potentially explosive areas (EEx d IIC T6)
� Complete line of mounting and protective accessories
Parameter settings� Measuring range� Emissivity� Smoothing constant� Maximum value memory
Functions� Automatic monitoring of pyrome-
ter internal temperature� Simulation of current and tem-
perature
PC Communication� Integrated software enables online
sensor configuration and data transmission
� Simple communication using Windows® Hyperterminal
� CellaMevis® data recording and visualisation software featuresgraphic user interface
LED Spot Light� For the series ARDOCELL PL, PQ
27/28/38� LED spot light for continuous indi-
cation of exact target spot� LED does not influence the measu-
rement� Measurement spot as small as
1.5 mm
Fibre OpticsFor pyrometers featuring fibre optics,the electronics are housed separatelyfrom the fibre optic sensor head. A fibreoptic cable transmits the infrared radia-tion to the electronics assembly.The optical sensor head can withstandambient temperatures up to 250 °Cwithout cooling. Due to their compactsize (Ø 30 mm and 16 mm) these sensorheads can be installed in cramped, hard-to-access locations. The fibre optic cablecan be unscrewed on both sides for easydetachment. The optical head is focus-able. A variety of lenses is available toaccommodate target spots as small as0.66 mm.
Industrial laser applications� PQ 27 with integrated filter to block
laser diode radiation.
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 4
Probedruck
C M Y CM MY CY CMY K
3
The right tool for the job, examples:
Moving or difficult-to-access objectsImmediate temperature readings for process monitoring and qualitycontrol of textiles, paper, coated sheet metals and plastic films.
Laser applicationsPurpose-built pyrometer model is resistant to diode laser radiationto provide fast temperature detection and monitoring.
Continuous casting of steel, rolling millsQuick temperature detection of slab products and rolled steel plates.
Resin extruders and moulding machinesTemperature monitoring during the plastic bottle manufacturingprocess.
Heat treatment of metalsDetection and optimal control of object temperature during inductionheating processes.
Cement plant, rotary kilnMeasurement of the temperature at the sintering zone and the clinkertemperature at the kiln inlet and outlet, checking of the shelltemperature in case of damage to the refractories.
Glass industrySpecial pyrometers accurately measure the surface temperatureduring plate glass and glassware manufacturing.
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 5
Probedruck
C M Y CM MY CY CMY K
Technical Data:ARDOCELL PQ Pyrometer Series
4
Target Diagrams1)
Version Low temperatureType PQ 11 AF… PQ 12 AF… PQ 13 AF... PQ 14 AF… PQ 15 AF… PQ 16 AF…Distance ratio 30:1 12:1 30:1 1.5:1 11:1 25:1
Focal distance 300 mm 300 mm 1000 mm 1000 mm 300 mm 100 mm
Ranges AF1: ±0 °C to +150 °C -30 °C to +70 °C ±0 °C to +250 °C ±0 °C to +150 °C ±0 °C to +150 °C
Order no 7MC3051-1AB11 7MC3051-1AB12 7MC3051-1AB13 7MC3051-1AB14 7MC3051-1AB16
Ranges AF2: ±0 °C to +300 °C -10 °C to +40 °C ±0 °C to +500 °C ±0 °C to +300 °C ±0 °C to +300 °C ±0 °C to +300 °C
Order no 7MC3051-1AC11 7MC3051-1AC12 7MC3051-1AC13 7MC3051-1AC14 7MC3051-1AC15 7MC3051-1AC16
Ranges AF3: ±0 °C to +500 °C -30 °C to +300 °C ±0 °C to +1000 °C ±0 °C to +500 °C ±0 °C to +500 °C
Order no 7MC3051-1AD11 7MC3051-1AD12 7MC3051-1AD13 7MC3051-1AD15 7MC3051-1AD16
Ranges AF4: ±0 °C to +800 °C ±0 °C to +800 °C
Order no 7MC3051-1AE11 7MC3051-1AE16
Ranges AF6: ±0 °C to +400 °C
Order no 7MC3051-1AG11
Ranges AF7: ±0 °C to +1000 °C
Order no 7MC3051-1AH11
Sensor thermopile
Spectral range 8 to 14 μm
Uncertainty (at ε=1 and Tu=23 °C) 1 % of reading, at least 1.5 K
Repeatability 1 K
Response time t90 ≤ 60 ms
Resolution ≤ 0.3 K
Length of enclosure A 123 mm 112 mm 123 mm
Length of tread B 35 mm
1) Taking into account optical tolerances at 90 % of the
maximum detected radiation
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 6
Probedruck
C M Y CM MY CY CMY K
Technical Data:ARDOCELL PQ Pyrometer Series
5
Version High temperatureType PQ 21 AF… PQ 22 AF… PQ 23 AF... PQ 24 AF… PQ 27 AF… PQ 28 AF… PQ 29 AF…Distance ratio 100:1 30:1 10:1 5:1 100:1 40:1
Focal distance 800 mm 1000 mm 300 mm 300 mm 200 mm 300 mm
Ranges AF1 +300 °C to +900 °C +150 °C to +800 °C
Order no 7MC3051-1AB21 7MC3051-1AB22 7MC3051-1AB23 7MC3051-1AB24 7MC3051-1AB27 7MC3051-1AB28 7MC3051-1AB29
Ranges AF2 +400 °C to +1400 °C
Order no 7MC3051-1AC21 7MC3051-1AC22 7MC3051-1AC23 7MC3051-1AC24 7MC3051-1AC27 7MC3051-1AC28 7MC3051-1AC29
Ranges AF3 +250 °C to +1600 °C
Order no 7MC3051-1AD21 7MC3051-1AD22 7MC3051-1AD23 7MC3051-1AD24 7MC3051-1AD27 7MC3051-1AD28 7MC3051-1AD29
Sensor photodiode
Spectral range 1.0 to 1.7 μm 1.2 to 1.7 μm 1.1 to 1.7 μm 1.8 to 2.2 μm
Target marker continous LED spotlight
Uncertainty 0.5 % of reading, 0.75 % of reading
(at ε=1 and Tu=23 °C) at least 4 K at least 5 K
Repeatability 1 K 2 K
Response time t90 ≤ 2 ms for T> +600 °C ≤ 2 ms for T> +300 °C
Resolution ≤ 0.45 K
Length of enclosure A 149 mm 112 mm 149 mm 189 mm 203 mm
Length of tread B 66 mm 35 mm 66 mm 100 mm 56 mm
Target Diagrams1)
1) Taking into account optical tolerances at 90 % of the
maximum detected radiation
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 7
Probedruck
C M Y CM MY CY CMY K
Technical Data:ARDOCELL PQ Pyrometer Series
6
Target Diagrams1)
Version High temperature Glass Surface PyrometerType PQ 31 AF… PQ 32 AF… PQ 38 AF... PQ 41 AF… PQ 42 AF…
1) Taking into account optical tolerances at 90 % of the
maximum detected radiation
Distance ratio 120:1 30:1 100:1 30:1 50:1
Focal distance 800 mm 1000 mm 200 mm 400 mm 400 mm
Ranges AF1: +700 °C to +1400 °C +300 °C to +1300 °C +700 °C to +1500 °C
Order no 7MC3051-1AB31 7MC3051-1AB32 7MC3051-1AB38 7MC3051-1AB41 7MC3051-1AB42
Ranges AF2: +800 °C to +2000 °C +1000 °C to +2500 °C
Order no 7MC3051-1AC31 7MC3051-1AC32 7MC3051-1AC38 7MC3051-1AC42
Ranges AF3: +1000 °C to +2500 °C
Order no 7MC3051-1AD31 7MC3051-1AD32 7MC3051-1AD38
Ranges AF4: +500 °C to +2500 °C
Order no 7MC3051-1AE31 7MC3051-1AE32 7MC3051-1AE38
Sensor photodiode thermopile
Spectral range 0.78 to 1.06 μm 4.6 to 4.9 μm
Target marker continous LED Spotlight
Uncertainty (at ε=1 and Tu=23 °C) 0.3 % of reading, at least 4 K 1 % of reading, at least 5 K
Repeatability 1 K 4 K
Response time t90 < 2 ms for T> +900 °C ≤ 200 ms ≤ 100 ms
Resolution ≤ 0.65 K ≤ 0.65 K
Length of enclosure A 149 mm 112 mm 189 mm 149 mm
Length of tread B 66 mm 35 mm 100 mm 66 mm
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 8
Probedruck
C M Y CM MY CY CMY K
Technical Data:ARDOCELL PQ Pyrometer Series
Selectable for any of the above models: either Kevlar (<85 °C) or metal-sheathed (<250 °C) fibre optic cable.
7
Version Pyrometers with fibre opticsType PQ 26 AF… PQ 26 AF… PQ 36 AF... PQ 36 AF…Optics PZ 41.31 PZ 41.28 PZ 41.31 PZ 41.28
Distance ratio 80:1 50:1 80:1 50:1
Focal distance 0.15 m to ∞ 0.12 m to ∞ 0.15 m to ∞ 0.12 m to ∞
Ranges AF1 +300 °C to +2000 °C +700 °C to +1400 °C
Order no 7MC3051-1AB26 7MC3051-1AB36
Ranges AF2 +800 °C to +2000 °C
Order no 7MC3051-1AC36
Ranges AF3 +550 °C to +2500 °C
Order no 7MC3051-1AD36
Ranges AF21 +300 °C to +2000 °C +700 °C to +1400 °C
Order no 7MC3051-1CB26 7MC3051-1CB36
Ranges AF23 +550 °C to +2500 °C
Order no 7MC3051-1CD36
Sensor photodiode
Spectral range 1.0 to 1.7 μm 0.78 to 1.06 μm
Uncertainty 0.5 % of reading,
(at ε=1 and Tu=23 °C) at least 4 K
Repeatability 2 K
Response time t90 ≤ 2 ms for T> +700 °C ≤ 2 ms for T> +1000 °C
Resolution ≤ 0.55 K ≤ 0.65 K
Length of enclosure A 125 mm
Length of tread B 35 mm
Target Diagrams1)
Sensor head Ø 30 mm Sensor head Ø 16 mm
1) Taking into account optical tolerances at 90 % of the
maximum detected radiation
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 9
Probedruck
C M Y CM MY CY CMY K
Technical Data:ARDOCELL PL Pyrometer Series
8
Version Pyrometer with focusable opticsType PL 11 AF… PL 21 AF… PL 22 AF... PL 31 AF… PL 32 AF…Distance ratio 30:1 100:1 100:1 100:1 100:1
Focal distance 200 mm to 500 mm 500 mm to ∞ 200 mm to 500 mm 500 mm to ∞
Ranges AF1: ±0 °C to +250 °C +300 °C to +900 °C +700 °C to +1400 °C
Order no 7MC3071-1AB11 7MC3071-1AB21 7MC3071-1AB22 7MC3071-1AB31 7MC3071-1AB32
Ranges AF2: ±0 °C to +500 °C +400 °C to +1400 °C +800 °C to +2000 °C
Order no 7MC3071-1AC11 7MC3071-1AC21 7MC3071-1AC22 7MC3071-1AC31 7MC3071-1AC 32
Ranges AF3: ±0 °C to +800 °C +250 °C to +1600 °C +1000 °C to +2500 °C
Order no 7MC3071-1AD11 7MC3071-1AD21 7MC3071-1AD22 7MC3071-1AD31 7MC3071-1AD 32
Ranges AF4: ±0 °C to +1000 °C +500 °C to +2500 °C
Order no 7MC3071-1AE11 7MC3071-1AE31 7MC3071-1AE 32
Sensor thermopile photodiode
Spectral range 8 to 14 μm 1.0 to 1.7 μm 0.78 to 1.06 μm
Target marker continous LED SpotlightUncertainty 1 % of reading, 0.5 % of reading, 0.3 % of reading,(at ε=1 and Tu=23 °C) at least 1.5 K at least 4 K at least 4 K
Repeatability 1 K
Response time t90 ≤ 60 ms ≤ 2 ms for T> +600 °C ≤ 2 ms for T> +900 °C
Resolution 0.3 K 0.45 K 0,.5 K
Length of enclosure A 203 mm 202 mm
Length of tread B 56 mm 100 mm
Target Diagrams1)
1) Taking into account optical tolerances at 90 % of the
maximum detected radiation
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 10
Probedruck
C M Y CM MY CY CMY K
Common Specifications
Dimensions:
1) available with an optional VK 11/C-USB PC connection box
9
Analogue outputLoadLinearisationAmbient temperatureOverheating controlStorage temperatureLED displayPower supplyPermissible humidityEnclosureLength of enclosure AMountingConnectionWeightProtectionEmissivity ε Setting Range Increments
0 (4) to 20 mA linear, switchable, scalable1)
max. 500 OhmDigital via microcontroller±0 °C to +65 °C (without cooling accessory)Output switches to > 20.5 mA when internal temperature exceeds 80 °C-20 °C to + 80 °C4-digit (digit height 8 mm)24 V DC +10 %/-20 % current consumption ≤ 50 mA ripple ≤ 200 mV95 % RH (non-condensing)stainless steel112 to 202 mmwith outer thread M 30 x 1.5via plugapprox. 0.35 kgIP 65 (DIN 40050) when plug is connectedExternally via 8-bit cable (binary signal, static)ε = 0.100 to 0.9960.0039
PQ compact model
PQ with fibre optics
PL with focusable optics
Sensor head Ø 30 mm
Sensor head Ø 16 mm
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 11
Probedruck
C M Y CM MY CY CMY K
Supplementary lensesAttaching an additional lens to the pyrometerenables various target spot sizes as small asØ 1.2 mm.
Protective windowA protective window can be placed in frontof the lense to protect it.
PS 01/X pressure-proofenclosureFor pyrometer use in potentially explosiveatmospheres. Certified EEx d IIC T6.
PS 01/A air purgePrevents dirt or dust from settling on thepyrometer's lenses or quartz window. Circularairflow provides maximum efficiency withminimal air consumption.
PS 01/R mirror attachmentDeflects infrared radiation 90° whenattached in front of the pyrometer.
PZ 20/X AF 5 oscillatingmirrorDeflects the radiation emitted fromthe target for hot spot recognitionor measurement of thin target ob-jects. Can be mounted in front ofany PZ or PQ model pyrometer. Cou-pled to the pyrometer, the PZ 20/Xcan act as a scanner and generate atemperature profile across a targetarea. Using a digital interface, thedata can be transmitted to a PC.
PS 01/K insulation tubePrevents heat transfer from the hotaccessories to the pyrometer.
PS 11/N bayonet connectorEnables quick pyrometer dismoun-ting, e.g. when the optics requirecleaning.
ZA 01/Q intermediate tubeEnhances the purging effect of thePS 01/A by increasing the air cushionto keep the lens free of dust anddebris.
PS 01/N mounting flangeFor wall mounting or ceiling sus-pension.
PS 11/U mounting bracketEnables vertical or horizontal pyro-meter mounting.
10
VK 01/K AF 5 terminal boxwith cableFeatures integrated emissivityswitch.
PS 01/B cooling jacketCan be operated with air or water. Surroundsthe pyrometer and protects it against highambient temperatures.
VK 11/C-USB PC connectionboxInterconnection between pyrometerand PC
Accessories and Fittings
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 12
Probedruck
C M Y CM MY CY CMY K
ARDOCELL PQ, PL
Connection socket for 24 V DCpower supply
0/4...20 mA24 VDC
VK 11/C-USB PC connection box
PS 21-010
PS 01-008
PS 01-048
11
PC CommunicationThe VK 11/C-USB PC connection box can be easily inserted into thepyrometer's connection cable during initial installation or field service.The plug connector enables on-site connection in a matter of secondswithout interrupting operations.
To check if peripheral equipment such as the signal conditioner oranalogue scaling is functioning properly, an output signal can besimulated.
The connection box is especially convenient when performing on-sitetest measurements because it enables connection to a PC in a matterof seconds. To provide the pyrometer with an electrical current, thepower supply is simply connected to the box, thus creating a mains-independent data acquisition system.
Combination Examples and PC Communication
Due to their modular design, the ARDOCELLPQ Series accessories enable a wide varietyof combinations, thus creating customisedassemblies to meet the requirements ofspecific measuring tasks and serve specialapplications.
The PS 21-010 assembly is used with chamberkilns and tunnel kilns.The PS 01/K insulation tube provides electricaldecoupling and insulates the pyrometer fromheat. The PS 11/N bayonet coupling with
optionally integrated protective window doesnot require tools to dismount the assembly. Thisfacilitates easy cleaning of the optics and a quickview of the measurement point within the kiln.When combined, the PS 01/A air purge, ZA 01/Mintermediate tube and ZA 01/C dust stop generatea laminar air flow. This ensures that the protectivewindow and pyrometer optics remain perfectlyclean. The ZA 01/E ball flange provides maximumflexibility in pyrometer alignment.
The PS 01-008 assembly offers comprehensivepyrometer protection. The PS 01/B cooling jacketallows the pyrometer to be installed in ambienttemperatures up to 200 °C.The protective window safeguards the pyro-meter's optical system against damage. The airpurge prevents dirt and dust from settling onthe the protective window.
The PS 01-048 assembly makes it possible to install the pyrometer evenin the harshest industrial conditions.The PS 01/A air purge generates an air flow in the ZA 01/Q intermediatetube, thus keeping dirt and debris off of the pyrometer optics. ThePS 11/K mounting bracket enables the pyrometer to mounting at anyangle.
Pyrometer_Bro_PQ_0708_GB.fh11 18.08.2008 10:39 Uhr Seite 1
Probedruck
C M Y CM MY CY CMY K
More Information
Siemens AGIndustry SectorIndustry Solutions DivisionIndustrial TechnologiesI IS IN OLM LS ITMP.O. Box 3220D-91058 Erlangen, GermanyE-Mail: [email protected]
Theinformation in this document containsgeneral descriptions of the technical optionsavailable, which do not always have to bepresent in individual cases. The requiredfeatures should therefore be specified in eachindividual case at the time of closing thecontract.
All designations used in this document canbe trademarks the use of which by thirdparties for their own purposes could violatethe rights of their owners.
© Siemens AG 2008.All Rights Reserved.
www.siemens.de/sirent
Bestell-No.: E10001-T430-A59-V1-7600Printed in GermanyDispo No. 21646 K-No. 38300NOR C-ISOL5208M0702 WS 07081Subject to change without prior notice