Aqua Tanker

download Aqua Tanker

of 11

Transcript of Aqua Tanker

  • 7/31/2019 Aqua Tanker

    1/11

    Transportation of Water from

    Kimberley to PerthAquatankers

    2004 United Nations Association of Australia World Environment Day Awards- Finalist

    2003 6 year contract with Capt Cook Cruises2002 SEDA NSW Green Ambassador

    2001 Winner Australian Design Award of the Year 2001 Engineering

    2001 Australian Technology Award PWC/Technology Transactions - Finalist

    2001 Australian Technology Showcase Patrons Award - Finalist

    2000 Winner International Cargo Handling Co-ordination Association Award Cargo Handling

    2000 Winner Boating Industry Association of Australia Marine Awards Best New Product 2000

    1999 Winner Far Eastern Economic Review/Du Pont Asian Innovation Award Gold Medal 2000

    1997 Winner Advanced Technology Boat Race Canberra Australia Major Prize 1997

  • 7/31/2019 Aqua Tanker

    2/11

    Aquatankers Consortium

    Solar Sailor Holdings, Ltd Australian Company based in Sydney

    Military subsidiary in US (Unmanned Ocean Vehicles) Investment support from Europe - Germany (Mithril Eur 600m fund)

    Global patents on wing design, unique expertise / designs in hybrid marine

    power systems,

    AMSEC LLC / M. Rosenblatt & Son One of the worlds leading naval architecture,

    Marine engineering, ocean engineering and industrial engineering firms, Seven offices and over 400 engineering, design and logistics personnel.

    Partnership between Science Applications International Corporation

    (SAIC) and the Newport News Division of Northrop Grumman Corporation

    Science Applications International Corporation Largest employee-owned research and engineering company in the United

    States, 45,000 employees at offices in more than 150 cities worldwide

    Extensive experience with environmental assessment programs

    Experienced with environmental impact analyses

    Working with indigenous US communities

    SAIC is a global leader in risk and reliability assessment

    Capability highlights and experience

  • 7/31/2019 Aqua Tanker

    3/11

    Aquatankers Proposal

    1. Aquatankers is proposing a Build, Operate & Transfer solutions

    2. Key Assumption - 20 years license

    3. Cost Estimates based on:

    Capital expenses - $710m AUD approx - includes

    Single Point Moorings (SPMs) x 2 each able to dock up to 8 ships,

    Ships and

    Shoreside transfer stations

    System suitable for a 70 gigaliter transport. This is the TOTAL construction and acquisition cost of all ships, land

    acquisition, shore side facilities and associated outfitting

    4. Aquatankers will lead:

    Engineer - include all necessary economic and social impact studies, a

    complete risk assessment, reliability analysis for the entire system and majorcomponents

    Procure, Install and Commission (EPIC),

    Operate the vessels and port facilities for an agreed time period (20 years

    assumed)

    Conditionally transfer the operation and ownership of the physical assets to

    the government at the end of the given time period

  • 7/31/2019 Aqua Tanker

    4/11

    Aquatankers Solution

    Super-Tankers

    specially designed and

    constructed for the

    carriage of potable

    water

    Optional Solar Sailor

    wing sails

    reducing fuel

    consumption and

    emissions up to

    - 40-60% from wind

    - 2% from sun

    Aquatankers expects to meet the required annual 50 gigaliter quantity, but actually deliver

    closer to 70 gigaliters, using three ships and a single SPM at each port

    SPM

    SPM

    2 Single Point

    Moorings

    Kimberley

    Perth

    Estimates that the cost of

    transporting water, 1.20

    AUD/tonne or 1.20 MAUD/gigaliter without Solar

    Sail technology and 0.95

    AUD/tonne or 0.95 M

    AUD/gigaliter with the Solar

    Sail technology

  • 7/31/2019 Aqua Tanker

    5/11

    Bulk Carrier Retro-fit Normal drive

  • 7/31/2019 Aqua Tanker

    6/11

    Aquatankers Benefits

    Environmental Benefits:

    Land Use Minimal:

    Includes onshore transfer facilities, temporary water storage tanks, short pipeline runs from the transfer facilities and thecollection source and municipal distribution network.

    No Interference from SPMs

    The SPMs, are placed far enough from shore as to not interfere with the sea grasses or other shoreline issues.

    Ships

    The Aqua Tankers estimated to be better than a pipeline or aquaduct because the length and elevation changes of the routeare substantial

    Solar Sailor Wings - established up to 50% fuel efficiency using proven technology currently in commercial operation today

    Even without the benefits of Solar Sailor technology - Estimated that ships are

    300 times more efficient than over the road trucks,

    100 times more efficient than rail and

    50 percent more efficient than desalination..

    1

  • 7/31/2019 Aqua Tanker

    7/11

    Aquatankers Benefits

    Social Benefits:

    Non land based solution avoids difficulties in

    Environmentally sensitive areas,

    Urban or ex-urban areas, or

    Where indigenous population issues are present.

    Development Time:

    Turn-Key Solution with new ships in four years of contract (shorter if start with existing ships) including:

    designed, procurement,

    constructed and

    commissioned.

    Reliability and Risk:

    Tank ships Safe & Flexible

    Safest and most reliable transport vehicles or distribution methods ever developed.

    Solution provides redundancy and eliminates the elements of risk associated with a system of single components connectedin series.

    Deliver to / from a variety of ports as required

    2

  • 7/31/2019 Aqua Tanker

    8/11

    Aquatankers Benefits

    Scalability:

    Additional ships and SPMs could meet additional capacity requirements and increase the reliability.

    Estimated 200 gigaliters - ten ships and four SPMs at each port

    Proven Technology:

    All aspects of solution uses existing, off-the-shelf technology for every aspect of the program.

    over 1,500 ships tank ships built in this size range,

    hundreds of SPMs and thousands of kilometers of sub sea pipelines.

    Wing sail and Solar Sailor technology has been successfully applied to ships and marine craft commercially.

    Economic:

    Ships are readily financed on good projects - WHY? If a ship does not work out for a particular trade route, it can generally be sold

    for application in another trade program. If an aquaduct is not used, it becomes useless and not suitably for alternative productssuch as oil or gas

    Capital costs become relatively fixed compared to other industrial projects because the capital costs are largely contained within theship and equipment procurements rather than land and permitting components.

    It is generally agreed that the aquaduct system for New York City, which includes three aquaducts, numerous reservoirs, dams,bridges and tunnels could not be built in todays environment because of the cost and environmental impacts

    3

  • 7/31/2019 Aqua Tanker

    9/11

    Aquatankers Questions / Answers

    1. Infrastructure:

    Offshore buoys, sub-sea pipeline to shore, shore distribution to/from pumping station, storage capacity for the ships in the range of 2-3 ships

    (load) and 2 ships on the discharge.

    The load side from the storage tanks to the water source is not clearly identifiable because we are not sure of how the panel envisions

    extracting water from the source, nor are we exactly sure of the source. On the discharge side, the connection goes from the storage (reallya surge or head tank) is piped directly into the municipal treatment or distribution systems.

    The surge tanks are there to smooth the flow from a steady flow process (source/discharge) to the parcel load/distribution from the ships.

    Refueling and stores of the ships can be handled by conventional supply boats or bunker barges. This is a standard mode for shipping. The

    nature of this project indicate that stores and refueling will only need to be done on one end (load or disport).

    2. Storage capacity of the tankers:

    Anywhere from 330,000 m3 to 550,000 m3 per ship depending on the project requirements and market forces.

    3. Separate Ballast Tanks:

    Yes. While it might not be required from a health point of view, elements related to tank coatings, custody transfer and efficiency of operation

    effectively require separate ballast tanks.

    4. Would purpose built tankers for water transport be single of double skin hull construction?

    Double skin.

    5. What is the cycle time for a round trip and what loading and unloading times are assumed?

    The cycle time is based largely on the load port location and the speed of the vessels--which is driven largely by a calculation of fuel

    consumption and capital expense.

    Load/discharge times are estimated in the range of 20,000-50,0000 m3/hr.

    Cycle times, for a 2,000km voyage is approx. one week (based on key assumptions).

  • 7/31/2019 Aqua Tanker

    10/11

    Aquatankers Questions / Answers

    6. What provisions need to be made for operating during the cyclone season? What is the estimated downtime per annum due to bad weather?

    Ships of this type are remarkably resistant to weather. However, they do slow down in bad weather. However, we have estimated an

    operating uptime of 330 days per year to account for weather and maintenance as consistent with normal shipping practice.

    7. Could tankers be unloaded without the need for additional storage facilities i.e. discharged directly into the existing water distribution system?

    Yes. But the cost would probably be higher because ships are an expensive storage facility compared to on typical shore tanks of similar

    size.

    8. What would be the expected water quality at the delivery point and would treatment be required?

    Water quality at discharge is directly dependent on the water quality at load. We are proposing all treatment to be done at the discharge

    side so all import water would be treated either in the existing municipal systems or standalone.

    9. Would it be possible to remove oil contamination inside existing tankers previously used for carrying oil? What would need to be done to make

    them suitable for water transport?

    It is possible, but very expensive. There are some risks inherent in this type of effort and water treatment facilities would probably be

    necessary to account for some of the residues that might be released from the steel even years later.

    10. Please describe how the operation could be scaled up to meet an increased annual demand from 50 gigalitres to 200 gigalitres. What changes to

    infrastructure would be required? The infrastructure of 2 bouys, if designed properly, would already have the capacity of 200 gigaliters. For the ships, it is a matter of adding

    more ships as required to meet the government's needs.

  • 7/31/2019 Aqua Tanker

    11/11

    Relative ComparisonsFactor Shipping Towed Bags Pipeline Canal Desalination

    Reliability

    Ease of Installation

    Ease of Operation

    Financing

    Time to First Water

    Environment

    Economies of Scale

    Scalability (Cap Flex)

    CAPEX

    OPEX

    Energy Consumption

    System Flexibility

    Security

    Average +0.46 +0.85 +0.15