Applied Geometry. - lindner-group.com...Building new solutions. Lindner undertakes major projects...

28
Applied Geometry. Lindner Post Cap Ceilings and Plafotherm ® Post Cap Heated/Chilled Ceilings Concepts Products Service

Transcript of Applied Geometry. - lindner-group.com...Building new solutions. Lindner undertakes major projects...

1

Applied Geometry.Lindner Post Cap Ceilings and Plafotherm® Post Cap Heated/Chilled Ceilings

Concepts

Products

Service

2

����������������������

Building newsolutions.

Lindner undertakes major projects worldwide in all areas of interior fit-out, insulation technology,industrial services and building facades. Frompre-planning through to project completion Lindneris your partner of choice.

The Company’s extensive manufacturing capabilityenables quality to be strictly maintained whilstallowing maximum flexibility to meet individualproject requirements.

Environmental considerations are fundamental to allLindner’s business principles.

Through partnerships with clients Lindner turnsconcepts into reality.

Choosing Lindner you have:Lindner Concepts:Tailored solutions specifically geared to satisfy individual project requirements

Lindner Products:Quality materials and systems to the very highest industry standards

Lindner Service:Comprehensive project management services

3

Main photo: Palmas Altas, Spain© Mark Bentley Photography

Choosing Lindner you have:

These well-directed ceiling constructions with Post Cap profiles can be adapted to every building shape and offer versatile scope for design. All avenues of ceiling design are open thanks to freely selectable distances of Post Cap profiles and our range of diverse ceilings with Post Caps and Cross Noggins.

A special visual variant are radially installed Post Caps combined with trapezoidal metal ceiling panels. Post Cap ceilings allow you to install partition walls to the Post Cap profiles. Thus, you can flexibly change your room layout.

The Post Cap ceilings can perfectly be emphasised with Lindner Luminaires. In addition, we offer a pleasant climate thanks to our integrated efficient heating and cooling technologies.

Lindner Post Cap CeilingsStraightforward, robust and really high-profile.

Customer benefits at a glance- Variable spacing between the post caps or ceiling panels of different sizes- Fixing of partition walls to post cap profiles- Wide choice of perforations- Smoothly integrated Lindner Lighting Systems- Integrated Heating and Cooling Systems create a pleasant temperature

Bosch, Karlsruhe, Germany

4

ContentLMD Post Cap Ceilings 6 LMD-B 100 8 LMD-B 110 10 LMD-B 111 12 Sound absorption 14 Building material class 14 Longitudinal sound reduction 15Plafotherm® Heated/Chilled Post Cap Ceilings 16 Programme 17 Heating and Cooling 18 Building material class 19 Sound absorption 20 Longitudinal sound reduction 20 Hydraulic Components 21Lindner Lighting Systems 22Post Cap Options 23Joint Designs 24Wall Connections 25Surfaces 26Green Building 27

5

Torre Espacio, Madrid, Spain© Mark Bentley Photography

6

LMD Post Cap CeilingsSystem Page

LMD-B 100

Linear Post Cap CeilingPost Cap profiles visible, ceiling panels Lay-In, with Hook-On edge or withSwing-Down option

8 - 9

LMD-B 110

Post Cap Ceiling with Cross NogginsPost Cap profiles and Cross Noggins visible, ceiling panels Lay-In, with Hook-On edge or with Swing-Down option

10 - 11

LMD-B 111

Post Cap Ceiling with Cross Noggins and Crossing BoxesPost Cap profiles and Cross Noggins visible,ceiling panels Lay-In, with Hook-On edge or withSwing-Down option

12 - 13

Additional functions Page

LMD-B .... SD Longitudinally sound-reduced ceilings 15

7

Tested quality

Building material class A2-s1, d0 tested to EN 13501-1Class A (IBC) tested to ASTM E 84Class 0 tested to BS 476 part 6/7

Sound absorption up to sound absorption class Atested to EN ISO 354

Durabilityexposure class Atested to EN 13964, table 8 and 9

Light reflectance approx. 82 %9010 acc. to Lindner, unperforatedtested to DIN 5033

Assessment of flue gas tested to DIN 4102, part 1 – Annex CHarmless toxicity of flue gas

Additional functions

Rated normalized flanking soundlevel differenceDn,f,w tested in laboratory acc. tovalid standard

Certification / Regulations

Execution of the system ceilingstested to EN 13964

Quality standard according to the technical regulations of TAIM (Association of Indust-rial Metal Ceiling Manufacturers TAIM e.V.)

Technical data

Metal ceiling system

Ceiling panelLength up to 3,300 mm, width up to 1,250 mm, made of zinc-galvanised steel, powder-coated, aluminium or stainless steel available on request, depending on the system

Edges Square

PerforationAvailable in all standard perforations depending on panel dimensions resp. material, see Surface Brochure

SurfaceElectrostatically applied powder-coatingfurther surfaces see Surface Brochure

Colour 9010 acc. to Lindner, other colors in RAL and NCS availabe

SubstructurePost Cap profile manufactured from galvanised sheet steel, roll-formed orbent steel profile in standard widths of 100, 125, 150 and 200 mm includingsuspension, special widths of Post Cap profile available on request

Relevant norms DIN EN 10152 / 10327 / 13964, DIN EN ISO 12944

Environmental product declarationsvalidated to ISO 14025

8

LMD-B 100 features post cap profiles in standard widths of 100, 125, 150 and 200 mm. If necessary, partition walls can be attached to the post cap profi-les by means of additional bracings.

Post Cap ceilings are maintenance-friendly and well-priced ceiling systems. Ceiling panels Type 1 (Lay-In), Type 2 (Lay-In with Hook-On edge) and Type 3 (Lay-In with Hook-On notch) may be used separately or in combination.

Tried and tested, but never excelled.Linear Post Cap Ceiling – Post Cap profiles visible, ceiling panels Lay-In with Hook-On edge or Swing-Down option.

LMD-B 100

If frequent maintenance work is required, the robust Swing-Down mechanism is the perfect match. The ceiling panels’ reliable swing-down mechanism makes it very easy to access the ceiling cavity. The

mechanism can be operated single-handedly with a special tool to allow the panel to swing down. An economically favourable combination of Swing-Down and Lay-In panels is possible.

9

Standard requirements

System Detail Installation detail

LMD-B 100 Type 1Lay-InLength up to 3,300 mm, Width up to 1,250 mm

LMD-B 100 Type 2Lay-In with Hook-On edgeLength up to 3,300 mm, Width up to 1,250 mm

LMD-B 100 Type 3Lay-In with Hook-On notchLength up to 3,300 mm,Width up to 1,250 mm

LMD-B 100 Type 4Lay-In, Swing-Down option on longitudinal sideLength up to 3,000 mm, width up to 1,250 mm

LMD-B 100 Type 6Lay-In, Swing-Down option on short sideLength up to 3,000 mm,width up to 1,250 mm

Hinging and locking

elements are protected

by DBGM.

Panel length Panel lengthPost cap width

3 3

30 -

50

95

Panel length Panel lengthPost cap width

3 3

30 -

50

95

Panel length Panel lengthPost cap width

3 3

30 -

50

95Panel length Panel length

~3

Post cap width

~3

30 -

50

≥95

Panel length Panel length

~3

Post cap width

~3

30 -

50

≥95

10

Extends your options.Post Cap Ceiling with Cross Noggins – Post Cap profiles and Cross Noggins visible, ceiling panels Lay-In with Hook-On edge or Swing-Down option.

LMD-B 110

This ceiling system consists of suspended linear post caps with attached cross noggins, both available in widths of 100, 125, 150 and 200 mm. Ceiling panels

are installed from above. As well as its pleasing visual LMD-B 110 scores with its option for partition connection in any direction along the post cap.

If frequent maintenance work is required, the robust Swing-Down mechanism is the perfect match. The ceiling panels’ reliable swing-down mechanism makes it very easy to access the ceiling cavity. The

mechanism can be operated single-handedly with a special tool to allow the panel to swing down. An economically favourable combination of Swing-Down and Lay-In panels is possible.

11

Standard requirements

System Detail Installation detail

LMD-B 110 Type 1Lay-InLength up to 3,300 mm, Width up to 1,250 mm

LMD-B 110 Type 2Lay-In with Hook-On edgeLength up to 3,300 mm, Width up to 1,250 mm

LMD-B 110 Type 3Lay-In with Hook-On notchLength up to 3,300 mm,Width up to 1,250 mm

LMD-B 110 Type 4Lay-In, Swing-Down option on longitudinal sideLength up to 3,000 mm, Width up to 1,250 mm

LMD-B 110 Type 6Lay-In, Swing-Down option on short sideLength up to 3,000 mm,width up to 1,250 mm

Panel length Panel lengthPost cap width

3 3

30 -

50

Panel length Panel lengthPost cap width

3 3

30 -

50

Panel length Panel lengthPost capwidth

3 3

30 -

50

~3 ~3

30 -

50

Panel length Panel lengthPost cap width

~3 ~3

30 -

50

Panel length Panel lengthPost cap width

Hinging and locking

elements are protected

by DBGM.

12

Tightly crossed.Post Cap Ceiling with Cross Noggins and Crossing Boxes – longitudinal post cap and post cap cross noggin visible, suspension in crossing box, ceiling panels Lay-In with Hook-On edge or Swing-Down option.

LMD-B 111

The distinct visual of this ceiling system is created with suspended crossing boxes and Hook-On cross noggins. Ceiling panels Type 1 (Lay-In), Type 2 (Lay-

In with Hook-On edge) and Type 3 (Lay-In with Hook-On notch) may be used separately or in combination.

If frequent maintenance work is required, the robust Swing-Down mechanism is the perfect match. The ceiling panels’ reliable swing-down mechanism makes it very easy to access the ceiling cavity. The

mechanism can be operated single-handedly with a special tool to allow the panel to swing down. An economically favourable combination of Swing-Down and Lay-In panels is possible.

13

System Detail Installation detail

LMD-B 111 Type 1Lay-InLength up to 3,300 mm, Width up to 1,250 mm

LMD-B 111 Type 2Lay-In with Hook-On edgeLength up to 3,300 mm, Width up to 1,250 mm

LMD-B 111 Type 3Lay-In with Hook-On notchLength up to 3,300 mm,Width up to 1,250 mm

LMD-B 111 Type 4Lay-In, Swing-Down option onlongitudinal sideLength up to 3,000 mm,Width up to 1,250 mm

LMD-B 111 Type 6Lay-In, Swing-Down option on short sideLength up to 3,000 mm,width up to 1,250 mm

Standard requirements

Panel length Panel lengthPost capwidth

3 3

30 -

50

Panel length Panel lengthPost capwidth

3 3

30 -

50

Panel length Panel lengthPost capwidth

3 3

30 -

50

~3 ~3

30 -

50

Panel length Panel lengthPost cap width

~3 ~3

30 -

50

Panel length Panel lengthPost cap width

Hinging and locking

elements are protected

by DBGM.

14

Rg 0,7 - 4Hole diameter 0.7 mmopen area 4 %valid for steel 0.6 mmacoustic tissue

αw = 0.70SAA / αs,m = 0.71NRC = 0.70

Rd 1,6 - 25Hole diameter 1.6 mmopen area 25 %valid for steel 0.6 mm acoustic tissue

αw = 0.70SAA / αs,m = 0.70NRC = 0.70

Rv 1,8 - 20Hole diameter 1.8 mmopen area 20 %valid for steel 0.6 mm acoustic tissue

αw = 0.75 (L)SAA / αs,m = 0.73NRC = 0.75

Rg 2,5 - 16Hole diameter 2.5 mmopen area 16 %valid for steel 0.6 mm acoustic tissue

αw = 0.80 (L)SAA / αs,m = 0.81NRC = 0.80

Rg 2,5 - 16Hole diameter 2.5 mmopen area 16 %valid for steel 0.6 mm acoustic tissue andSound absorption inlay

αw = 1,0 (L)SAA / αs,m = 0.92NRC = 0.95

3.1

3.1

3.83

3.323.32

5.5

5.5

5.5

5.5

0,00,20,40,60,81,0

125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent α

s

Frequency in Hz

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

Frequency in Hz

0,00,20,40,60,81,0

125 500 1000 2000 4000250

Example of the range of standard perforations available for ceilings without Heating and Cooling Technology

0,00,20,40,60,81,0

125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

Frequency in Hz

Product Building material class

LMD Metal ceiling panelMetal ceiling panel manufactured from galvanized sheet steel, including powder-coated surface in colour 9010 acc. to Lindner and bonded acoustic tissue on the reverse side

A2-s1, d0 tested to EN 13501-1

Insula Mineral wool inlayMineral wool shrink-wrapped in acoustic transparent foilInsula A2Insula IInsula Basic

A2-s1, d0 tested to EN 13501-1 B1 tested to DIN 4102-1B2 tested to DIN 4102-1

Building material class

Sound absorption

22

22

15

Longitudinal sound reductionToday, modern buildings are expected to satisfy high demands. Design, performance, security and flexibility as well as long-term profitability must be granted. Furthermore, rooms have to make the people therein feel comfortable. All this can be accomplished by using longitudinally sound-reduced Lindner ceilings available with a range of different inlays. It goes without saying that we always provide for our ceiling panels to be easy to remove in case of maintenance works.

LMD-B 100 SD Lay-In sandwich elements Dn,f,w = 45 dB without barrier

LMD-B 100 SD Lay-In sandwich elements, mineral wool Dn,f,w = 49 dB without barrier

LMD-B 100 SDLay-In sandwich elements, mineral wool, barrier on one side

Dn,f,w = 64 dB with barrier

LMD-B 100 SDLay-In sandwich elements, mineral wool, barrier on both sides

Dn,f,w = 67 dB with barrier

LMD-B 129 SD1)

Lay-In/Swing-Down sandwich elements, mineral wool, fastening of partition walls in Post Cap grooves

Dn,f,w = 48 dB without barrier

LMD-B 137 SD1)Lay-In sandwich elements, mineral wool, fastening of partition walls in joints

Dn,f,w = 48 dB without barrier

LMD-B 100 SD

LMD-B 129 SD LMD-B 137 SD

1) Minimum purchase quantity for post cap profiles on request

LMD-B 100 SD with barrier

16

Plafotherm® Heated/Chilled Post Cap Ceilings

The integrated Heating and Cooling Technologies of Plafotherm® B create a pleasant temperature for any living and working environment. The tried and tested post cap system ensures safe handling. We will be glad to give your metal ceiling a distinctive look by applying one of our many eye-catching Lindner surfaces.

Longitudinally sound-reduced Plafotherm® B ... SD Heated/Chilled ceilings provide for utmost flexibility when it comes to changing the floor plan in the sim-plest way. For this reason, these ceilings are in many cases installed in combination with movable partition walls. The heating and cooling system is particularly suitable to ensure room-to-room sound absorption as it may provide for excellent longitudinal sound re-duction values between 43 dB and 62 dB, depending on the construction.

17

Programme

System

Plafotherm® B 100

Linear Heated and Chilled Post Cap Ceiling Post Cap profiles visible, ceiling panels Lay-In, with Hook-On edge or with Swing-Down option

Plafotherm® B 110

Heated and Chilled Post Cap Ceiling with Cross Noggins Post Cap profiles and Cross Noggins visible, ceiling panels Lay-In, with Hook-On edge or withSwing-Down option

Plafotherm® B 111

Heated and Chilled Post Cap Ceiling with Cross Noggins and Crossing BoxesPost Cap profiles and Cross Noggins visible, suspension in crossing box, ceiling panels Lay-In, with Hook-On edge or with Swing-Down option

Plafotherm® B 100 SDLinear Heated and Chilled Post Cap Ceiling, longitudinally sound-reducedLay-In sandwich elements

Plafotherm® B 137 SD

Linear Heated and Chilled Post Cap Ceiling, longitudinally sound-reducedLay-In sandwich elements, fastening of partition walls in joints

Tested quality

Building material class A2-s2, d0 tested to EN 13501-1

Sound absorption up to sound absorption class Btested to EN ISO 354

Durabilityexposure class Atested to EN 13964, table 8 and 9

Light reflectance approx. 82 %9010 acc. to Lindner, unperforatedtested to DIN 5033

Nominal cooling capacity 120 W/m²tested to DIN EN 14240 (10 K)Nominal heating capacity 133 W/m²tested to DIN EN 14037 (15 K)

Certification / Regulations

Execution of the system ceilingstested to EN 13964

Quality standard according to the technical regulations of TAIM (Association of Indust-rial Metal Ceiling Manufacturers TAIM e.V.)

Environmental product declarationsvalidated to ISO 14025

18

Heating and Cooling

Heat conducting profile with Cu-pipe fret

Heating/Cooling technology

consisting of aluminium heat conducting profile with copper pipe fret, integrated into ceiling panel for thermal conductivity

Heat conducting profile aluminium profile plain or perforated, standard widths of 80 and 120 mm

Pipe fret copper coil, 12 x 0.5 mm

Water volume approx. 1 l/m²

Centre distance from 90 mm on

Nominal cooling capacity acc. to DIN EN 14240 (10K)

112 W/m²

Nominal heating capacity acc. to DIN EN 14037 (15K)

126 W/m²

Heat conducting profile with stainless-pipe fret

Heating/Cooling technology

consisting of aluminium heat conducting profile with stainless pipe fret, integrated into ceiling panel for thermal conductivity

Heat conducting profile aluminium profile plain or perforated, standard widths of 80 and 120 mm

Pipe fret stainless, 12 x 0.5 mm

Water volume approx. 1 l/m²

Centre distance from 90 mm on

Nominal cooling capacity acc. to DIN EN 14240 (10K)

109 W/m²

Nominal heating capacity acc. to DIN EN 14037 (15K)

123 W/m²

6,0 8,0 10,0 12,0 14,020

40

60

80

100

140

120

160

180

200Cooling

Sp

ecif

ic c

apac

ity

[W/m

²]

Excess or insufficient temperature [K]

Heating

6.0

Sp

ecif

ic c

apac

ity

[W/m

²]

8.0 10.0 12.0 14.0

40

60

80

100

120

160

140

180

200

Excess or insufficient temperature [K]

CoolingHeating

20

19

Heating and Cooling

Recomended operation dataFlow temperature (cooling) 15 - 17 °CTemperature spread 2 - 4 KFlow temperature (heating) 30 - 35 °CTemperature spread 4 - 6 KRecomended pressure drops 25 - 30 kPa

Determination of excess and insufficient temperature

ΔTK = insufficient temperature (cooling) [K]ΔTH = excess temperature (heating) [K]hR = room temperature [C°]hVL = flow temperature [C°]hRL = return-flow temperature [C°]

ΔTK = hR – hVL + hRL

ΔTH = hVL + hRL – hR

2

2

Graphite panel with Cu-pipe fret

Heating/Cooling technology

consisting of graphite panel with copper pipe fret, integrated into ceiling panel for thermal conductivity

Heat conducting profile heat conducting graphite panel plain

Pipe fret copper coil, 12 x 0.5 mm

Water volume approx. 1 l/m²

Centre distance 100 mm

Nominal cooling capacity acc. to DIN EN 14240 (10K)

120 W/m²

Nominal heating capacity acc. to DIN EN 14037 (15K)

133 W/m²

6.0 8.0 10.0 12.0 14.020

40

60

80

100

140

120

160

180

200

Sp

ecif

ic c

apac

ity

[W/m

²]

Excess or insufficient temperature [K]

CoolingHeating

Product Building material class

Plafotherm® metal ceiling panelMetal ceiling panel manufactured from galvanized sheet steel, inclu-ding powder-coated surface in colour 9010 acc. to Lindner, bonded acoustic tissue on the reverse side and heat conducting profile

A2-s2, d0 tested to EN 13501-1

Insula Mineral wool inlayMineral wool shrink-wrapped in acoustic transparent foil

Insula A2Insula IInsula Basic

A2-s1, d0 tested to EN 13501-1 B1 tested to DIN 4102-1B2 tested to DIN 4102-1

Building material class

20

Sound absorption

Plafotherm® B 100 SD Dn,f,w = 48 dBLay-in sandwich elements,without barrier

Plafotherm® B 100 SD Dn,f,w = 62 dBLay-in sandwich elements,with barrier

Plafotherm® B 137 SD Dn,f,w = 48 dBLay-in sandwich elements,without barrier

Longitudinal sound reduction

Example of possible standard perforations for Heated and Chilled Ceilings with heat conducting profiles.

Rv 2,0 - 20hole diameter 2.0 mmopen area 20 %heat conducting profileacoustic tissuemineral wool lining

αw = 0.55 (LM)SAA / αs,m = 0.69NRC = 0.70

Rg 2,5 - 16hole diameter 2.5 mmopen area 16 %heat conducting profile acoustic tissuemineral wool lining

αw = 0.50 (L)SAA / αs,m = 0.64NRC = 0.65

Rv 1,8 - 20hole diameter 1.8 mmopen area 20 %acoustically effective heat conducting profileacoustic tissuemineral wool lining

αw = 0.80SAA / αs,m = 0.79NRC = 0.80

Rv 1,8 - 20hole diameter 1.8 mmopen area 20 %acoustically effective heat conducting profileacoustic tissue

αw = 0.70 (L)SAA / αs,m = 0.74NRC = 0.75

Standard heat conducting profile

Acoustically effective heat conducting profile

4.3

3.72 3.72

5.5

5.5

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

3.83

3.323.32

3.83

3.323.32

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

So

un

d a

bso

rpti

on

coef

fici

ent

s�

0,00,20,40,60,81,0

Frequency in Hz125 500 1000 2000 4000250

21

Hydraulic ComponentsFor perfect connections.For perfect heating and cooling connections, Lindner provides a great number of hydraulic components and accessory parts.

Advantages: - Tested system- One-stop solutions

Connection hoses and fittingsHigh-grade steel hoses are oxygen impermeable, tested to DIN 4726, and are used as connection hoses. These hoses are perfectly suited to accept a large number of fittings. The quick plug connector MultiQuickConnect does without retaining claws which unnecessarily damage the meanders. Thus, a quick and user-friendly installation and removal is ensured. A locking button that clearly sticks out checks the correct installation and guarantees a posi-tive connection and a secure hold. A system distributor with three outgoing lines completes the system.

- Ideal for heating/cooling systems- Maintained independently from other building trades

22

Lindner Lighting SystemsIntegration is our passion.Lindner has a wide range of lighting fixtures that fulfill even the most demanding requirements.

High efficiency lamps

Even illumination

Frameless and flushwith the ceiling

No deviations in colour to the ceiling panel

Factory-assembled/delivered as a unit

Highlysound-absorbent

Can be equipped with heating/cooling technologies

Light ChannelsThe length and the execution of the light channels can flexibly be adapted to the room geometry. Moreover, they impress from the technology to the easy installation.

Integrated LuminairesA wide range of integrated luminaires is available. These luminaires are shapely integrated into ceiling panels. Moreover, they are adapted to the room concept and the lighting quality.

System LuminairesA multitude of system luminaires which are perfectly adapted to the ceiling systems regarding dimensions, installation and colour deviation are available.

E.ON Ruhrgas AG, Essen, Germany© Klaus Michelmann

23

Standard C-post cap

C-post cap with 13 mm centre groove

Partition wall attachment requires additional

bracing

C-shadow gap post cap

Lay-In post cap

Aluminium Drop-Slide post capwidth: 150 mm

Metal ceiling suspended with lowerable and movable ceiling panels

Post cap for reduced ceiling to soffit height

Post cap directly fixed with compensation bracket to concrete ceiling

Post Cap OptionsInstallation possibilities

100125150

100 Standard

100

38 -

50

mm

100

150

24

The visual of the ceiling system can be influenced by a selection of different joint designs. Besides aesthetic aspects, the joint design can also have an effect on the acoustic performance. Determine your choice of joint width by ordering panels with different spacers.

Joint Designs

Panel width Panel widthEither 1 or 3 mm

Gasket filled joint

Panel width Panel width

~ 3 mm

Joint with embossed panel turn-up

Panel width Panel widthEither 3 or 5 mm

Panel abutment with joint and spacer

Butt joint

Panel width Panel width

25

Wall connections can be realised in different ways - with and without shadow gap. To ensure that cut panels rest entirely on the trim’s supporting finish without any corrugation, hold-down clips and sheets are applied. Specially designed trims for columns provide for a clean connection to curved shapes.

Wall Connections

L-trim

Shadow gap trim

Pillar semiring

Further wall connections available on request.

26

SurfacesLindner has a wide range of ceiling surfaces for different demands – so that your rooms are not only extraordinary but unique. We apply various colours, patterns, graphics, 3D textures and perforations to your metal ceiling. In particularly challenging areas, we furnish our systems with coatings that are more than just eye-catchers: They create a significant improvement of room quality.

Possible surfaces

- Powder Coating - Design Surface ARTline – Design Powder Coating GRAPHICline – Print Technology EFFECTline – Grinding Technology SPREADline – Customised, image and scattered perforation - Functional Surfaces Meteo – Corrosion Coating Mutex – Absorber Coating

- Special Surfaces INOXlook – Aluminium with appearance of stainless steel - Structured Surfaces TOUCHdesign – 3D Surface TOUCHdesign Lunar – 3D high-gloss Surface TOUCHdesign Venas – 3D Structured Surface TOUCHdesign Viva – 3D Expanded Metal Surface - Expanded Metal - Perforations

Tsvetnoy Market, Moscow, Russia© Chris GascoigneUnilever, Hamburg, Germany

Dubai Metro Station, UAEVR-Bank, Heilbronn, Germany© Volker Erich Jahr

27

A responsible approach to humans and nature is a matter of course for us as a manufacturer of long lasting ceiling systems in premium quality. We are continuously optimizing our wide range with the objective to further reduce their impact on the environment. Every production step is subject to a thorough control of the ambitious energy, material and quality requirements. This ensures that our clients do not only get a sophisticated product but that they can also rely on the ecological suitability.

Validated environmental product declarations according to ISO 14025 are available for the procedure of proof of the environmental performance of Lindner ceiling systems.

Sustainable construction with Lindner ceiling systems:- Extremely durable products with best functional

characteristics and high economic efficiency- End-to-end procedure of proof of the ecological

material characteristics by environmental product declarations

- Consultancy service with all current building certifications, as for example according to DGNB, LEED, BREEAM

Lindner is a founding member of the German Sustainable Building Council (DGNB) and member of the US Green Building Council. We are actively involved in building up awareness for the principles of sustainable construction and the development of relevant standards.

Simply healthier: Lindner ceiling systems.- High recycling percentage up to 45 %- VOC values are considerably below the limit according to AgBB / DIBt- Free from toxicological gases, thus it is toxicologically inoffensive in case of fire according to DIN 53436- The substances used for pre-cleaning of powder coating are no hazardous substances according to the

Ordinance on Hazardous Substances.- Powder recovery of surface coating of approx. 25 %- Reference useful life is 70 years according verified EPD- Up to 30 % of the primary energy demand can be saved with Plafotherm® heated and chilled ceiling

systems

Green Building

Unilever, Hamburg, Germany

28

Lindner Group

Bahnhofstrasse 2994424 Arnstorf Germany Phone +49 8723 20-3679Fax +49 8723 [email protected]

This document is the intellectual property of Lindner, Arnstorf (Germany). All the information contained in this brochure agrees with the information available at the time of its printing and only serves as advance information. Any possible colour deviations there might be from the original product are caused by printing-related reasons. Lindner is the sole and exclusive owner of the copyrights as well as the ancillary copyright. All use, and in particular any distribution, reprinting, exploitation or adaptation of this document shall only be allowed with express, written approval by Lindner.

TU

_D_B

/E/3

.4

Lindner Concepts:

- Airports and Railways- Clean Rooms and Operating Theatres- Cruise Liner and Ship Fit-out- General Contracting- Hotels and Resorts- Insulation and Industrial Service- Interior Fit-out and Furnishings- Special-Purpose Constructions and Stadiums- Studios and Concert Halls- System Buildings

Lindner Products:

- Ceiling Systems- Doors- Dry Lining Systems- Facades- Floor Systems- Heating and Cooling Technologies- Lights and Lighting Systems- Partition Systems- Roofing Systems- Steel & Glass

Lindner Service:

- Clearance of Harmful Substances- Construction Management and Project Development- Deconstruction and Interior Demolition- General Planning- Global Product Supplies- Green Building- Industrial Scaffolding- Installation and Building Services- Research and Development

We can do it all for you.