Application Product Construction Technical Data
ü�Conductor : Finely Stranded Annealed
Electro Tinned Copper, Class 5.
ü�Insulation : Cross linked Silicone Rubber
ü�Screen : Tinned Copper Braid
ü�Outersheath : Cross linked Silicone Rubber
Black colour or as per Customer order.
ü�Cables are used in Driver desks, Control panels, wiring harness in inside/outside moving vehicles.
0 0ü�Temperature Range : -40 C to +120 C.
ü�Rated Voltage : 3.6/6kV
ü�Specification : BS EN 50382 - 2
In addition to BS EN 50382 spec, cables
also meet fire performance tests as per
EN 50306-2
DIN 5510-2
BS 6853
NF F 16-101
2D View
Featuresü�Excellent resistance to high and low temperatureü�Outstanding Flame retardant ü�Halogen freeü�Thin walled with excellent flexibilityü�Resistance to Oil, fuel,ozone and weathering.ü�Easy to stripü�Low smoke densityü�Soldering iron resistantü�Electron Beam Cross Linked.ü�Resistance to corona effect.
Wires & Cables
Cross Section2 (mm )Part Number
Outer diameter (mm) (Nom)
Note : XX* & YY*: Please add last two digits in the part number as per the colour code given hereunder replacing XX while ordering.
Red - 01 Yellow - 02 Blue - 03 Black - 04 Green - 05 Yellow-Green - 06 Grey - 07 Brown - 08 White - 09 Orange - 10 Violet - 11
Chocolate - 12 Tan - 13 Charcoal - 14 LT Blue - 15 DK Grey - 16 LT Green - 17 DK Green - 18 DK Blue - 19 Purple - 20 Pink - 21
0Siechem BS EN 50382-2 Single Core, Screened, 1.8/3kV, EBXL 120 C High Temperature Rolling Stock Cable
Catalogue No.
570
www.siechem.com
All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
32
0Siechem EN 50382-2 Single Core, Screened 1.8/3kV AC, EBXL 120 C High Temp Rolling Stock Cable
Cable Weight (Kg/Km) approx.
*57013XXYY
57016XXYY
57019XXYY
57023XXYY
57027XXYY
57028XXYY
57030XXYY
57032XXYY
57034XXYY
57037XXYY
57038XXYY
57041XXYY
57042XXYY
57044XXYY
57046XXYY
57048XXYY
57049XXYY
30 X 0.25
50 X 0.25
56 X 0.30
84 X 0.30
80 X 0.40
126 X 0.40
196 X 0.40
276 X 0.40
396 X 0.40
360 X 0.50
475 X 0.50
608 X 0.50
756 X 0.50
925 X 0.50
1221 X0.50
1525 X 0.50
2013 X 0.50
Conductor Diameter (mm)
1.5
1.95
2.5
3.0
3.9
5.0
6.4
7.7
9.2
11.0
12.5
14.2
15.8
17.5
20.1
22.5
25.8
Insulation Thickness(Nom.) ( mm)
Sheath Thickness(Nom.) ( mm)
1.3
1.3
1.3
1.3
1.3
1.5
1.5
1.8
1.8
1.8
1.8
2.2
2.2
2.4
2.4
2.4
2.6
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.5
1.5
1.6
1.6
1.7
1.8
1.9
2.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
0.393
0.277
0.210
0.164
0.132
0.108
0.0817
0.0654
0.0495
7.4
7.8
8.4
8.9
10.2
11.4
13.4
14.8
16.3
18.3
20.6
22.6
24.2
26.6
29.4
32.1
36.1
111
131
168
201
277
373
528
668
864
1151
1453
1783
2144
2554
3252
3935
5067
Conductor Construction No.of Strands x Strand dia Nos x mm
Max conductor 0resistance at 20 C
Ω/km
OHSAS 18001
AS 9100
ISO45001
ISO 9001
ISO 14001
RDSO