1
Application Product Construction Technical Data Features Wires & Cables ü Traceable ü Flame retardant ü Radiation stability ü Long term moisture ü Long term thermal endurance ü Stripping for ease of termination ü Radiation resistance up to 200 megarads 19 All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction. www.siechem.com Catalogue No Part Number Cable Diameter (Nom.) Insulation Thickness (Nom.) Cable Weight (approx.) mm mm kg/km Outer Sheath Thickness mm No.of Strands/ Strand dia Cond. Size (AWG) No.of Cond. 2/C 3/C 4/C 5/C 7/C 9/C 12/C 19/C 25/C 30/C 37/C 2/C 3/C 4/C 5/C 7/C 9/C 12/C 19/C 25/C 30/C 37/C 2/C 3/C 4/C 5/C 7/C 9/C 12/C 19/C 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 12 12 12 10 10 10 10 10 10 10 10 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.615 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 7/0.77 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 1.14 1.14 1.14 1.14 1.52 1.52 1.52 2.03 2.03 2.03 2.03 1.14 1.14 1.14 1.52 1.52 1.52 1.52 2.03 2.03 2.03 2.03 1.14 1.14 1.14 1.52 1.52 2.03 2.03 2.03 9.12 9.63 10.5 13.0 14.8 16.8 18.7 22.6 25.8 27.3 29.3 10.0 10.7 11.7 15.4 16.6 18.9 21.0 25.3 29.0 30.8 33.1 11.3 11.9 13.1 17.5 18.8 22.5 24.9 28.7 137 153 189 217 301 408 499 772 958 1200 1479 182 207 280 329 435 560 702 1073 1328 1536 1845 246 290 411 497 597 817 1018 1490 o Siechem Multicore Annealed Tinned Copper Conductor, XLPE 90 C Insulated 600 V Overall shield, rated Cable üRated voltage : 600 V o üTemperature rating :90 C üSpecification : (1) Class IE Qualified in accordance with IEEE 323-1974 and IEEE 383-1974 (2) ICEA S-73-532 (formerly ICEA S-66-524 & S-19-81) (3) ANSI N45.2 üFlame test : IEEE 383 (70,000 BTU/hr) as modified by NRC IEEE 383 (70,000 BTU/hr) IEEE 1202 (70,000 BTU/hr) ICEA T-29-520 (210,000 BTU/hr) UL VW-1 üControl cable is a 600 V overall shielded multi-conductor, thermoset, Class IE rated Construction specifically designed for application in nuclear generating stations and where flame retardancy is critical. ü Optimum performance is required for use on class IE circuits when shielding from external electrostatic interference is required ü Can be installed in trays, conduit, ducts or in direct burial applications. üConductor üInsulation ü Overall shield ü Outer sheath : : : : Annealed Tinned copper Conductor as per ASTM B33 Cross-Linked polyethylene o (EBXL-XLPE 90 C) Aluminium/polyester tape in contact with a stranded tinned copper drain wire Heavy duty chlorosulphonated Polyethylene (CSPE) o Siechem Multicore Annealed Tinned Copper Conductor, EBXL - XLPE 90 C Insulated 600 V Overall shield Cable 96179XX 96179XX 96179XX 96179XX 96179XX 96179XX 96179XX 96179XX 96179XX 96179XX 96179XX 96178XX 96178XX 96178XX 96178XX 96178XX 96178XX 96178XX 96178XX 96178XX 96178XX 96178XX 96177XX 96177XX 96177XX 96177XX 96177XX 96177XX 96177XX 96177XX 961 Drain Wire Size 16 16 16 16 16 16 16 16 16 16 16 14 14 14 14 14 14 14 14 14 14 14 12 12 12 12 12 12 12 12 mm OHSAS 18001 AS 14001 ISO 45001 ISO 9001 ISO/TS 16949 ISO 14001

Transcript of Application Product Construction Technical Data Cables/ATC... · 2016. 10. 14. · (4) ICEA...

Page 1: Application Product Construction Technical Data Cables/ATC... · 2016. 10. 14. · (4) ICEA S-95-658 (formerly ICEA S-66-524 & S-19-81) ü Control cable is a 600 V overall multi-conductor,

Application Product Construction Technical Data

Features

Wires & Cables

ü Traceable

ü Flame retardant

ü Radiation stability

ü Long term moisture

ü Long term thermal endurance

ü Stripping for ease of termination

ü Radiation resistance up to 200 megarads

19All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.

www.siechem.com

Catalogue No

Part Number Cable Diameter(Nom.)

Insulation Thickness (Nom.)

Cable Weight (approx.)

mm mm kg/km

Outer SheathThickness

mm

No.of Strands/Strand dia

Cond. Size(AWG)

No.of Cond.

2/C

3/C

4/C

5/C

7/C

9/C

12/C

19/C

25/C

30/C

37/C

2/C

3/C

4/C

5/C

7/C

9/C

12/C

19/C

25/C

30/C

37/C

2/C

3/C

4/C

5/C

7/C

9/C

12/C

19/C

14

14

14

14

14

14

14

14

14

14

14

12

12

12

12

12

12

12

12

12

12

12

10

10

10

10

10

10

10

10

7/0.615

7/0.615

7/0.615

7/0.615

7/0.615

7/0.615

7/0.615

7/0.615

7/0.615

7/0.615

7/0.615

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

7/0.77

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

0.76

1.14

1.14

1.14

1.14

1.52

1.52

1.52

2.03

2.03

2.03

2.03

1.14

1.14

1.14

1.52

1.52

1.52

1.52

2.03

2.03

2.03

2.03

1.14

1.14

1.14

1.52

1.52

2.03

2.03

2.03

9.12

9.63

10.5

13.0

14.8

16.8

18.7

22.6

25.8

27.3

29.3

10.0

10.7

11.7

15.4

16.6

18.9

21.0

25.3

29.0

30.8

33.1

11.3

11.9

13.1

17.5

18.8

22.5

24.9

28.7

137

153

189

217

301

408

499

772

958

1200

1479

182

207

280

329

435

560

702

1073

1328

1536

1845

246

290

411

497

597

817

1018

1490

oSiechem Multicore Annealed Tinned Copper Conductor, XLPE 90 C Insulated 600 V Overall shield, rated Cable

ü�Rated voltage : 600 Voü�Temperature rating :90 C

ü�Specification : (1) Class IE Qualified in accordance with

IEEE 323-1974 and IEEE 383-1974

(2) ICEA S-73-532 (formerly ICEA

S-66-524 & S-19-81)

(3) ANSI N45.2

ü�Flame test : IEEE 383 (70,000 BTU/hr) as modified by NRC

IEEE 383 (70,000 BTU/hr)

IEEE 1202 (70,000 BTU/hr)

ICEA T-29-520 (210,000 BTU/hr)

UL VW-1

ü�Control cable is a 600 V overall shielded

multi-conductor, thermoset, Class

IE rated Construction specifically

designed for application in nuclear

generating stations and where flame

retardancy is critical.

ü Optimum performance is required

for use on class IE circuits when shielding

from external electrostatic interference is required

ü Can be installed in trays, conduit,

ducts or in direct burial applications.

ü�Conductor

ü�Insulation

ü Overall shield

ü Outer sheath

:

:

:

:

Annealed Tinned copper

Conductor as per ASTM B33

Cross-Linked polyethylene o(EBXL-XLPE 90 C)

Aluminium/polyester tape in

contact with a stranded tinned

copper drain wire

Heavy duty chlorosulphonated

Polyethylene (CSPE)

oSiechem Multicore Annealed Tinned Copper Conductor, EBXL - XLPE 90 C Insulated 600 V Overall shield Cable

96179XX

96179XX

96179XX

96179XX

96179XX

96179XX

96179XX

96179XX

96179XX

96179XX

96179XX

96178XX

96178XX

96178XX

96178XX

96178XX

96178XX

96178XX

96178XX

96178XX

96178XX

96178XX

96177XX

96177XX

96177XX

96177XX

96177XX

96177XX

96177XX

96177XX

961

Drain Wire Size

16

16

16

16

16

16

16

16

16

16

16

14

14

14

14

14

14

14

14

14

14

14

12

12

12

12

12

12

12

12

mm

OHSAS 18001

AS

14001

ISO

45001 ISO 9001

ISO/TS 16949

ISO 14001