Application Product Construction Technical Data Cables/ATC... · 2016. 10. 14. · (4) ICEA...
Transcript of Application Product Construction Technical Data Cables/ATC... · 2016. 10. 14. · (4) ICEA...
Application Product Construction Technical Data
Features
Wires & Cables
ü Traceable
ü Flame retardant
ü Radiation stability
ü Long term moisture
ü Long term thermal endurance
ü Stripping for ease of termination
ü Radiation resistance up to 200 megarads
19All information given are in good faith.Siechem's liability is only to replace the defective portion of cables provided the same is mutually established as manufacturing defects within the guarantee period as agreed in writing and Siechem shall not be liable for any compensation or damages. Siechem reserves the right to revise any of the above specifications without prior intimation. Subject to Chennai Jurisdiction.
www.siechem.com
Catalogue No
Part Number Cable Diameter(Nom.)
Insulation Thickness (Nom.)
Cable Weight (approx.)
mm mm kg/km
Outer SheathThickness
mm
No.of Strands/Strand dia
Cond. Size(AWG)
No.of Cond.
2/C
3/C
4/C
5/C
7/C
9/C
12/C
19/C
25/C
30/C
37/C
2/C
3/C
4/C
5/C
7/C
9/C
12/C
19/C
25/C
30/C
37/C
2/C
3/C
4/C
5/C
7/C
9/C
12/C
19/C
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
10
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.615
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
7/0.77
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
0.76
1.14
1.14
1.14
1.14
1.52
1.52
1.52
2.03
2.03
2.03
2.03
1.14
1.14
1.14
1.52
1.52
1.52
1.52
2.03
2.03
2.03
2.03
1.14
1.14
1.14
1.52
1.52
2.03
2.03
2.03
9.12
9.63
10.5
13.0
14.8
16.8
18.7
22.6
25.8
27.3
29.3
10.0
10.7
11.7
15.4
16.6
18.9
21.0
25.3
29.0
30.8
33.1
11.3
11.9
13.1
17.5
18.8
22.5
24.9
28.7
137
153
189
217
301
408
499
772
958
1200
1479
182
207
280
329
435
560
702
1073
1328
1536
1845
246
290
411
497
597
817
1018
1490
oSiechem Multicore Annealed Tinned Copper Conductor, XLPE 90 C Insulated 600 V Overall shield, rated Cable
ü�Rated voltage : 600 Voü�Temperature rating :90 C
ü�Specification : (1) Class IE Qualified in accordance with
IEEE 323-1974 and IEEE 383-1974
(2) ICEA S-73-532 (formerly ICEA
S-66-524 & S-19-81)
(3) ANSI N45.2
ü�Flame test : IEEE 383 (70,000 BTU/hr) as modified by NRC
IEEE 383 (70,000 BTU/hr)
IEEE 1202 (70,000 BTU/hr)
ICEA T-29-520 (210,000 BTU/hr)
UL VW-1
ü�Control cable is a 600 V overall shielded
multi-conductor, thermoset, Class
IE rated Construction specifically
designed for application in nuclear
generating stations and where flame
retardancy is critical.
ü Optimum performance is required
for use on class IE circuits when shielding
from external electrostatic interference is required
ü Can be installed in trays, conduit,
ducts or in direct burial applications.
ü�Conductor
ü�Insulation
ü Overall shield
ü Outer sheath
:
:
:
:
Annealed Tinned copper
Conductor as per ASTM B33
Cross-Linked polyethylene o(EBXL-XLPE 90 C)
Aluminium/polyester tape in
contact with a stranded tinned
copper drain wire
Heavy duty chlorosulphonated
Polyethylene (CSPE)
oSiechem Multicore Annealed Tinned Copper Conductor, EBXL - XLPE 90 C Insulated 600 V Overall shield Cable
96179XX
96179XX
96179XX
96179XX
96179XX
96179XX
96179XX
96179XX
96179XX
96179XX
96179XX
96178XX
96178XX
96178XX
96178XX
96178XX
96178XX
96178XX
96178XX
96178XX
96178XX
96178XX
96177XX
96177XX
96177XX
96177XX
96177XX
96177XX
96177XX
96177XX
961
Drain Wire Size
16
16
16
16
16
16
16
16
16
16
16
14
14
14
14
14
14
14
14
14
14
14
12
12
12
12
12
12
12
12
mm
OHSAS 18001
AS
14001
ISO
45001 ISO 9001
ISO/TS 16949
ISO 14001