AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output...

24
PLEASE READ AND SAVE ALL INSTRUCTIONS! LISEZ ET CONSERVEZ TOUTES LES INSTRUCTIONS! ¡POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES! AOS 7145 / 7147 www.sylvane.com 1-800-934-9194

Transcript of AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output...

Page 1: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

PLEASE READ AND SAVEALL INSTRUCTIONS!

LISEZ ET CONSERVEZTOUTES LES INSTRUCTIONS!

¡POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES!

AOS 7145 / 7147

www.sylvane.com 1-800-934-9194

Page 2: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

www.sylvane.com 1-800-934-9194

Page 3: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

3

Instructions for use (5 – 22) en

Instructions d’utilisation (23 – 40) a fr

Instrucciones para el uso (41 – 57) a es

www.sylvane.com 1-800-934-9194

Page 4: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

4

www.sylvane.com 1-800-934-9194

Page 5: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

5

enInstructions for use

www.sylvane.com 1-800-934-9194

Page 6: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

6

en

Important safety instructions• Priortousingtheappliance,readthroughthein­structionsforcompleteuseandretaininasafeplaceforlaterreference.

• WARNING–OnlyusetheUltrasonicindoorsandwithinthespecifiedtechnicaldata.Improperusecanbehazardousforthehealthandleadtocriticalinjury.

• Connecttheunitonlytoalternatingcurrentwithvoltageaccordingtotheratinglabel.

• Childrencannotrecognizethehazardsassociatedwiththeusageofelectricalappliances.Forthisreason,alwayssupervisechildrenwhentheyarenearthehumidifier(image1).

• Neverusetheapplianceifthereisanydamagetotheapplianceorcable(2),aftermalfunction,aftertheappliancehasbeendropped(3)ordamagedinanyotherway.

• Repairsofelectricalappliancesareonlytobemadebyqualifiedserviceengineers(4).Improperrepairworkcancauseconsiderabledangertotheuser.

• Placethehumidifieronadry,levelsurface(5).• Do not place the appliance directly on the floorornexttoaheatingvent(6).

• Ifthemistcomesincontactwiththefloorpriortoevaporating,thefloorsurfacecanbecomedamaged.Wedonotacceptanyliabilityfordamagesinthecaseofincorrectplacementoftheunit.

• Theunitshouldbeplacedinanelevatedposition(7),e.g.onatable,chestofdrawers,etc.

• Placeappliancewhereitisnoteasilyknockedover(8).• Alwaysunplugwhennotinuse.• Onlyoperatethehumidifierwhenitiscompletelyassembled.

• ALWAYSunplugbeforeremoving/filling/emptyingthewatertank,beforecleaning/maintaining,assembling/dismantlingofindividualpartsandbeforemovingtheappliance.

• Donottouchthewaterinthebaseduringoperationbecauseofhighfrequencyvibrationsinthewater.

• Donotrunpowercordsundercarpets,anddonotco­verwiththrowrugs.Arrangecordsothatitwillnotbetrippedover.

• Neverpulltheplugfromtheoutletbythecableorwithwethands.

• Donotusetheappliancewherecombustiblegasesorvaporsarepresent.

• Donotexposetheappliancetorain,orusenearwater,inabathroom,laundryareaorotherdamplocation.

• Thisunitmustbeusedinitsuprightposition.• Donotallowforeignobjectstoenterventilationorexhaustopeningasthismaycauseelectricshockordamagetotheappliance.Donotblockairoutletsorintakes.

• Donotpourwaterintothemistoutletoftheappliance.• Thisappliancehasapolarizedplug(onebladeiswiderthantheother).Toreduceriskofshock,thisplugisintendedtofitinapolarizedoutletonlyoneway.Iftheplugdoesnotfitfullyintheoutlet,reversetheplug.Ifitstilldoesnotfit,contactaqualifiedelectrician.DONOTattempttodefeatthissafetyfeature.

• Aloosefitbetweentheplug(receptacle)andtheACoutletmaycauseoverheatingandadistortionoftheplug.Contactaqualifiedelectriciantoreplacelooseorwornreceptacles.

• Donotsit,standorplaceanyheavyobjectsontheappliance.

• Donotsubmergethemainbodyinwaterorotherliquids.

• Disconnectpowersupplybeforeservicing.• Personswhoarenotfamiliarwiththeinstructionsforuse,aswellaschildrenandpersonsundertheinfluenceofmedication,alcohol,ordrugsarenotpermittedtooperatetheappliance,orareonlyper­mittedtooperateitundersupervision.

• Theuseofwateradditives,suchasethereal/essentialoils,fragrances,eucalyptus,waterconditionersetc.,damagesthetankmaterialandasaconsequencethewholeunit.Anyuseofsuchadditiveswillvoidthemanufacturer’swarranty.

• Remark:Neitherhumansnoranimalscanhearthehighfrequencyvibrations.

PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!www.sylvane.com 1-800-934-9194

Page 7: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

7

en

5

1

3

7

96

2

4

8

www.sylvane.com 1-800-934-9194

Page 8: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

8

en ForewordCongratulationsonchoosingtheUltrasonicHumidifierAOS7145/7147fromAIR­O­SWISS!

Didyouknowthatdryroomair:• Causesthemembranesinyourrespiratorysystemtodryout,andalsocauseschappedlipsandstingingeyes?

• Encouragesinfectionsandillnessesofrespiratorysystem?

• Causesweariness,tirednessandpoorconcentration?• Stresseshouseholdpetsandhouseplants?• Encouragestheformationofdustandtheelectrostaticchargingoftextilesmadeofsyntheticfibers,carpetsandplasticflooring?

• Damagesfurnishingsmadeofwoodandparquet?• Detunesmusicalinstruments?

General informationAcomfortableatmosphereindoorsisreachedwitharela­tivehumidity levelbetween40and60%.Yourhumidifierautomaticallycontrolsthehumiditylevelaccordingtothedesiredsetting.Iftheairistoodry,thehumidifierwillauto­maticallyswitchon.Assoonasthedesiredhumiditylevelisreached,itwillswitchoff.

Unpacking• Carefullyremovethehumidifierfromthebox.Placeyourhandsunderneaththeproducttopullitoutofthebox(10).

• Warning:Donottaketheunitoutoftheboxbypullinguponthetankhandle­basemayfallandwillbeda­maged(11).

•Removetheplasticbagfromthehumidifier.• Observetheinformationgivenontheratingplateaboutthevoltage.

• Usetheoriginalpackagingforstoringtheapplianceifyoudonotusethehumidifierallyearround.

10

11

www.sylvane.com 1-800-934-9194

Page 9: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

9

enDescription of the applianceMistoutlet(rotating)

Evaporationchamber

Watertank

Demineralizationcartridge

Mainbody

Controlpanel

Watertankcap

IonicSilverStick®

PowerPlug

Membrane

Brush

Nebulizerspace

www.sylvane.com 1-800-934-9194

Page 10: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

10

en Setting upFindingtheideallocationforyourunit:• Donotplacethehumidifierdirectlynexttoaheatingventoronafloorwithfloorheating.Themoistureofthemistcandamagethefloorsurface(6)(seeSafetyInstructions).

• Theunitshouldbeplacedinanelevatedposition(7),e.g.onatable,chest,etc.atleast3ftoffthefloor.

• Themistoutletmustnotbepointeddirectlyatplants,furniture,orotherobjects(12).Keepdistanceofatleast20inches(50cm).

• Soakthedemineralizationcartridgeinawaterbath24hoursbeforeusingit(13).Thegranuleshavetoab­sorbwatertoreachhighperformance.Ifthecartridgeissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.

• Onaveragethedemineralizationcartridgeshouldbereplacedevery2–3monthsdependingonyourwaterhardness.Someareasmayneedtoreplacethecart­ridgesooner,somemaylastlonger.Thecartridgemustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.

See«Replacementofthedemineralizationcartridge».• Readtheinstructionsunder«FillingtheTank»foraddingwaterinthehumidifier(14and15).

• Placethewatertankontothebase.• Inserttheplugintothesocketandswitchontheapplianceusingtheon/offdial(18and19).

• About10to15minutesafteritisswitchedonthede­vicewillreachitsfulloutputlevel.

• Makesurethatthecableisnotpinchedanywhere(9).Donotoperatethehumidifierifthecableisdamaged(2).

12

13

www.sylvane.com 1-800-934-9194

Page 11: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

11

en

16

17

15 18

19

14Filling the tankAlways unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!

Do not operate the humidifier when the water tank isempty!When thewater reaches theminimum level, theunitswitchesoffthenebulizerfunctionautomatically.Theemptyindicatorlightcomesonshowingtankisempty.

•Removethewatertankfromthebaseandunscrewthewatertankcap(14).

• Makesurethatnoforeignobjectsareinthewatertank.

• Fillthetankwithclean,coldwaterfromthetap(15).Closethecapofthewatertanksecurely,placethewa­tertankontothebase(16).Thewaterisnowrunningfromthetankintothebase.

• Donotpourwaterintothemistoutletoftheappliance(17).

• Inserttheplugintothesocket(18)andswitchontheapplianceusingtheon/offdial(19).Theemptyindi­catorlightmaystayilluminatedforsomesecondsuntilthebaseisfilledwithwater.

Do not use additivesWater additives (ethereal/essential oils, fragrances,eucalyptus, water conditioners, etc.) must not be used!Evenasmallamountcancausecracksinthematerial.Thematerialisn’tmadefortheuseofsuchadditives.Onedropisenoughtodamagethetankandasaconsequencetheunit.Anyuseofsuchadditiveswillvoidthemanufacturer’swarranty.

www.sylvane.com 1-800-934-9194

Page 12: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

12

en Operation AOS 7145

A) On/Off Dial and regulation of mist outputTurning the rotary dial clockwise switches the applianceonandat thesame time regulates themistoutput fromlowtohigh.

B) Hygrostat (setting the humidity level)Thedesiredhumiditylevelcanbesetbyturningtherotaryswitchclockwise.Arelativehumiditybetween40and60%isrecommended.Youcanachievethislevelbyrotatingtheswitchuntilitisroughlyintheverticalposition.Theaccu­racyofmeasurement is+/­5%.Theunitwill switchoffwhenthemoisturelevelexceedsthedesiredsetting.Theappliancedoesnotswitchoffiftheswitchisturnedalltheway to the right.Thisactivates thecontinuousoperationfunction.

C) Empty indicator (red)Thewaterleveliseasytosee,thankstothetransparentwatertank.Theappliancealsoalertsyouwhenthewa­tertankisempty.Theredemptyindicatorisilluminated(symbolC).Pleasereadthechapter«Fillingthetank»formoreinformation.TheredsymbolCmaystayilluminatedforsomesecondswitharefilledtankuntilthebaseisfilledwithwater.

A

B

C

www.sylvane.com 1-800-934-9194

Page 13: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

13

enOperation AOS 7147

A) On/Off DialYoucanswitchtheunitonoroffbypressingbuttonA.Thisbuttonisalsousedtoresetthecleaningindicatorlight(byholdingdown).

B) Hygrostat (setting the humidity level)BypressingbuttonByoucansetthedesiredhumiditylevelfrom30%to80%orCO(continuousoperation).Arelativehumiditybetween40and60%isrecommended.Theac­curacyofmeasurementis+/­5%.Theunitwillswitchoffwhenthemoisturelevelexceedsthedesiredsetting.Duringselectionthetargetvalueisdisplayed(symbol DESIRED).Thedisplaywillautomaticallyshowthecurrentvalueafterafewseconds(symbol CURRENT).

C) TimerUsing button C, the operation time can be set adjusta­blebetween1and8hoursorCO(continuousoperation).Symbol Gshowstheoperatingperiodthathasbeenset(1h/2h/3h/4h/5h/6h/7h/8h/CO).Thedisplaywillautomati­callyshowthecurrenthumidityafterafewseconds.

D) Mist output (regulating mist output)ByrepeatedlypressingbuttonDyoucancontrolthemistoutput.Symbol H showswhichof the three levels (low/medium/high)youhaveselected.

E) Operation with pre-heating (warm mist)ButtonEisusedforswitchingthepre­heatingonandoff(symbol Ilightsup).Asaresult,thewaterispre­heatedtoa temperatureof176°F (80 °C) beforeentering thenebulizerspace.Ittakesapprox.10to15minutesforthewater in thebase towarmup.Themistnow leaves thehumidifieratapleasanttemperatureof104°F(40°C).Theadvantageof this is that the roomtemperaturedoesnotdrop and, in addition, it significantly improves thewaterqualitymaintenance.

F) Automatic mode and Sleep modeTheautomaticandsleepmodescanbeactivatedbypres­singbuttonF.Bypressingthebuttononce,theautomaticfunctionisswitchedon(symbol Jappearsonthedisplay),maintainingtheoptimumhumiditysubjecttothetempera­ture.Controltakesplacebymeansofoutputquantityandpre­settargetvalue.Bypressingthebuttontwice,thesleepfunctionisswitchedon(symbol Kappearsonthedisplay),thetargethumidityis50–65%;theoperationtimeissetat6hoursandtheheatingisswitchedon.Inaddition,theoutputquantityisalsocontrolledsubjecttothedifferencebetweenthetargetvalueandtheactualvalue.Thehygrostatandmistoutputsettingscannotbechangedineithermode.IfthebuttonsBorDarepressed,theunitwillnolongerbeinautoorsleepmode.

G) Timer Indicator

H) Mist Output Indicator

I) Pre-heating Indicator

J) Automatic Mode Indicator

K) Sleep Mode Indicator

L) Empty indicatorThewater level iseasytosee,thankstothetransparentwatertank.Theappliancealsoalertsyouwhenthewatertankisempty.Theemptyindicatorisilluminated(symbolL).Pleasereadthechapter«Fillingthetank»formoreinforma­tion.ThesymbolLmaystayilluminatedforsomesecondswitharefilledtankuntilthebaseisfilledwithwater.

M) Cleaning indicatorIfsymbolM«CLEAN»appearsonthedisplay,theapplianceshouldbecleanedasrecommendedbythemanufacturer.Thissymbolcomesonautomaticallyevery2weeks,de­pendingonthelevelofuse.The display can be reset by holding down button A until the light disappears.

D

E

F

H

I

J

L

A

B

C

G

K

M

www.sylvane.com 1-800-934-9194

Page 14: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

14

en

ACID

23

22

21

20Cleaning/Maintenance Always unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!

Caution – risk of electric shock and damage of the product!

• Switchofftheappliance(20)andunplugitfromthesocketbeforecleaningit(21).

• Cleanthewatertankandthebaseregularly.Usewateronly,nodetergents(22).

• UseAIR­O­SWISSEZCalcustomcleaninganddescalingagentonlytoremovedepositsfromthemembranere­gularly(23).ThereisasampleofEZCalincludedinthepackagingofyourhumidifier.Instructionsforusingareonthepacket.Onlyuse1packetfor32ozofwater.Donotchangetheratio.DoNOTruntheunitwhenusingEZCal.Thiscancausedamagetotheproductandvoidsthewarranty.ThoroughlyrinsethebasewithpotablewaterafterusingEZCalandmakesurenoEZCalresi­duesremaininthebase.

EZCalfromAIR­O­SWISSistheonlyrecommen­dedcleaninganddescalingsolution.DoNOTuseanyothercleaningsolutionssinceitcandamagetheproduct.AnyuseofcleaningsolutionsapartfromEZCalwillvoidthewarranty.

• Makesuremainbodyisneversubmergedinwater(24)!

• AOS7147:Thecleaningindicatorstillappearsonthedisplayaftercleaning.ToresetitholddowntheON/OFFbuttonuntilthecleanlightdisappears.

• Cleantheinnerpartswithasoftcloth.Donotuseanysolventsoraggressivecleaningagentstocleantheappliance(25).

25

24

www.sylvane.com 1-800-934-9194

Page 15: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

15

en• Onlyusethebrushtocleanthemembrane.Thisshouldbedoneonceaweek.Onlyusethesoft­bristleportionofthebrush(26).

• Changethewaterinthetankatleastonceaweekifwaterisstandingformorethanaweek.

• Toremovethemistoutlet(27):Twistthemistoutlettoeithertherightortheleft.Alignthearrowonthemistoutletwiththearrowontheringaroundthemistoutlet.Onlyonesetofarrowsonmistoutletandringwillalign.Pulluponthemistoutletoncethearrowsarealigned.

Water quality maintenanceThe IonicSilverStick (ISS)uses theanti­microbialeffectof silver toprevent thegrowthofmicrobes in thewaterbase.Itbeginstofunctionassoonasitcomesintocontactwithwater,eveniftheunitisswitchedoff.TheIonicSilverStickshouldbechangedeveryyear.Lookatpicture28forthepositionoftheISSinthebasepartoftheunit.Donottouchthewaterinthebaseduringoperation!Switchofftheunitfirst.Contactyourlocalretailerorcheckourwebsitewww.airoswiss.netforreorderinformation.TheIonicSilverStick®comeswithametallicclipwhichcanberemovedfortheplacementinthisproducttype.

Lifecycle IndicatorYourappliancecomeswithalifecycleindicatorforchangingtheIonicSilverStick®.ToremindyourselfofwhenyouputtheISSintooperation,pleasecrossthecurrentmonthonthestampandwritethecurrentyearonthelineprovided(29).

26

28

29

27

www.sylvane.com 1-800-934-9194

Page 16: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

16

en 30

31

•Turntheplasticcupandcartridgeoverandshakeuntilallgranulesareinthecartridge(37).

•Removetheplasticcupandthepinkstyrofoampiecefromthecartridge(38)andretainforfutureuse(therefillgranulesconsistsof3refillbags)(39).

•Closethecartridge(40).•Soakthedemineralizationcartridgeinawaterbath 24hoursbeforeusingit(43).Thegranuleshavetoab­sorbwatertoreachhighperformance.Ifthecartridgeissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.

•Screwthecartridgeonthewatertankcap(44).•Screwthecartridgeonthebottomsideofthewatertank,putthetankonthemainbody(45).

Placinggranules in thecenterof thecartridgeallowsthemtoescapeintheunitortoclogtheunit.Theunitwillnolongeroperateproperlyandthegranulesneedtobecleanedoutthoroughly.

Option B: replace the whole cartridge•Removethewatertankfromthebaseandunscrewthewatertankcap(30).

•Thedemineralizationcartridgeisattachedtothetankcap.Unscrewthecartridgefromthecapbyturningitcounter­clockwise(31).Important:doNOTdisposeofthewatertankcap!

• Throwthewholecartridgeintothewaste(41).•Unpackthenewcartridge(42).•Soakthedemineralizationcartridgeinawaterbath24hoursbeforeusingit(43).Thegranuleshavetoab­sorbwatertoreachhighperformance.Ifthecartridgeissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.

•Screwthecartridgeonthewatertankcap(44).Closetankcapwellandplacethetankonthemainbody(45).

Replacement of the demineralization cartridge

Always unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!

Thewater tank is equippedwith a demineralization cart­ridge.Thiscartridgehastobereplacedevery2–3months.Ifthewaterisveryhard,itmaybenecessarytoreplacethecartridgeearlier.Whitedustaroundthedeviceisasuresignthatthecartridgeneedsreplacing.Ifwhiteresiduestillformsaroundthedeviceafteranewcartridgehasbeeninserted,pleasemakesurethatthewateryouareusingisuntreated.Ifthewaterflowsthroughadecalcificationsystem–suchasanionexchanger–(sodiumisaddedtoremovecalcium)inthebuildingbeforeitisusedinthehumidifier,saltcanpre­cipitateaswhitedustaroundthedevice.Thedemineralizationcartridge or the granulesmust be exchangedat the latestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.

Option A: replace the granules•Removethewatertankfromthebaseandunscrewthewatertankcap(30).

•Thedemineralizationcartridgeisattachedtothetankcap.Unscrewthecartridgefromthecapbyturningitcounter­clockwise(31).Important:doNOTdisposeofthewatertankcap!

•Openthecartridge(32).•Throwthecontentintothewaste(Attention!Disposedgranulescanmakethefloorslippery!)(33).

•Placetheenclosedpinkstyrofoampieceinthecenterofthecartridge.Donotpushittothebottomasitwillbedifficulttoremoveafterwards(34).

•Pourthecontentsofonerefillgranulesbagintotheplasticcupthatisincludedwiththerefillgranulespa­ckaging(35).

•Placetheemptycartridgewiththepluginthecenterontotheplasticcup(36).

32 33

www.sylvane.com 1-800-934-9194

Page 17: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

17

en

44

34 35

36

37

38

39

41

43

40

42 45

www.sylvane.com 1-800-934-9194

Page 18: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

18

en Storing the appliance for extended periodsCleantheapplianceasdescribedearlierandallowtodrythoroughly.Preferablystoretheapplianceinitsoriginalbox,inadryplaceawayfromhightemperatures.

Legal noticeThehumidifieriscUL­listed.Subject to technicalchange.The instructions foruseareprotectedbycopyright©PLASTONAG.

AccessoriesContact your local retailer or check our website www.airoswiss.netforre­orderinformation.

Customer ServiceCustomerService(USA)1­800­336­0326www.airoswiss.net

Technical data AOS 7145

Electricalvoltage 120V/60HzPowerconsumptionupto 45WHumidityoutputupto 3gallons/24hSuitableforroomsupto 600sqft/55m2

Dimensions(LxWxH) 9.5x10.3x12.2in 24x26x31cmWeight(empty) 6.6lbs/3kgAccessories Demineralizationcartridge IonicSilverStick®

Technical data AOS 7147

Electricalvoltage 120V/60HzPowerconsumptionupto 40W/(125W*)Humidityoutputupto 3.5gallons/24h*Suitableforroomsupto 650sqft/60m2

Dimensions(LxWxH) 9.5x10.3x12.2in 24x26x31cmWeight(empty) 6.6lbs/3kgAccessories Demineralizationcartridge IonicSilverStick®

*whenusedwithpre­heatingto176°F(80°C)

Troubleshooting

Problem Possible cause What to do

Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable

Nowaterinthetank(Emptyindicatoron) Filltankwithwaterandwait10min.

Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCal

Demineralizationcartridgeexhausted Replacecartridgeorgranules

Demineralizationcartridgeoverfilled Takeout2tablespoonsofgranulesandthrow withgranules themaway

Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min. thehumidifierwillworkproperlyagain

Mineraldepositsonmembrane CleanmembraneusingEZCalandbrush

Unitrunningintermittently

Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Replacedemineralizationcartridgeorgranules

www.sylvane.com 1-800-934-9194

Page 19: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

19

enGeneral Humidifier Questions

Q.Why isn’t there enough moisture in my room?A. Howoftendoyouruntheunit?Iftheunitisonlyrunatnight,thenduringthedaythemoisturelevelwilldropifmoistureisnotconstantlyaddedtotheair.

Q.Do you leave your door open or closed when the unit is running?

A. a) Byleavingthedooropen,thisallowsmoisturetoleavetheroomandgointootherareasofthehouse.Ifyouwouldlikethemoisturetostaywithinonespecificroomyoushouldconsiderclosingthedoorwhiletheunitisrunning.

A. b)Wood,leather,carpet,curtains,andothertypesoffabricsoakupalotofmoisture,thusnotleavingenoughmoisturefortheair.Ifthewindowisleftopen,thenthisallowsmoisturetoescapetheroom.Anotherfactorisalotoftimestheunitisplacednexttoaheatingdevice.Theideaisthattheairblowingintotheroomwillquicklyplacemoisturearoundtheroom.Unfortunately,thisconceptdoesnotworkbecausethehotaircomingoutofaventwillsoakupmostofthemoisture,andnoneoftheairwithintheroomwillreceiveany.

Q.How much moisture do I need in my room?A. Suggestedhumiditylevelsarebetween40–60%.

Q.What are the effects of too little or too much humidity?

A. Dryaircancausedryskin,staticelectricity,outoftunemusicalinstruments,increasedlevelsofdust(dryaircausesdusttorise),damagetowoodenobjects(dryoutandeventuallycracksappear),discomfort,sick­ness,anddriesoutnasalmembranes.

Over­humidifyingtheaircancausemoldandwallpapertopeel.

Q.Why do I need a humidifier when I can just open my window?

A. Themoisturelevelwithintheoutsideairisnothighenoughtohumidifyaroom.Thecoldertheairthelessmoistureitiscapabletohold,andthemoretheairisheatedupthepercentageofrelativehumidityislower.Relativehumiditymeanstheamountofwatervaporintheair,comparedtotheamounttheaircouldholdifitwastotallysaturated.Thedifferenceishigherbetweenoutsideandinsidetemperatures;morehumidificationisneededbecauseofthedryairintheroom.

Q.Where should I place my humidifier?A. Theunitshouldbefree­standingandnotclosetoawall,window,door,orthermalbridgesothatairmaycirculatearoundtheunit.

Ultrasonic Frequent Questions

Q.Why does it say open/close on the demineralization cartridge cap?

A. Thosedirectionsarethereincaseyoudecidetousetherefilloptiontoreplacethegranules;thepurposeisforhowtoopenandclosethecap.Ifyoudidopenthecapbeforeplacingitinthewatertank,youwillmostlikelynoticethattherearegranulesinthewatertankandthebaseoftheunit.Immediatelyturnofftheunit,andemptythewateroutofthebaseandthewatertank.Beginremovingallgranulesfrombaseandwatertank.Usebrushtocleanaroundmembrane.Caution:Donotdisposeofgranulesinsink!Usedgranulesmustgoinwaste!

Q. I just replaced my cartridge, and the contents and water in the base has turned a blue-green color.

A. Thissometimesoccurswhenthecartridge,oreventhegranules,arereplaced.Thisdoesnotoccurwithallreplacementcartridgesorgranules,andisareactionofwatercontentandtheUltrasonicvibrations.Thisisnotanindicatortoreplacethecartridge.

Q.There is no fill-line on the water tank, how far may I fill it up?

A. Thereisnofilllineonthewatertank,anditmaybefilledallthewaytothetop.

Q.What is the purpose of the demineralization cart-ridge (DMC)?

A. TheDMCremovesmineralsfromthewatertopreventwhitedust.Thecontentsofthecartridgeneedtobeso­akedfor24hrspriortofirstusingtheunitsothattheymayfullyexpandandremovemineralsfromthewater.ThecontentsoftheDMChavealifeof2–3months.Thecartridgemayneedtobereplacedmoreoftendependingonwaterhardnessandhowoftentheunitisused.AnindicationofwhentheDMCneedstobechangedcanbewhitedustorreducedamountofmistoutput.

Q. Is it ok to use distilled water with the unit?A. Forbestresultswithyourultrasonichumidifierusedistilledorreverse­osmosiswaterandremovethedemineralizationcartridge.

Q. I just replaced the contents of the cartridge and now have granules everywhere.

A. First,makesuretherearenogranulesinthemiddleofthecartridge.PlacinggranulesinthemiddleoftheDMCallowsthemtoescapeintheunit.Immediatelyturnofftheunit,andemptythewateroutofthebaseandthewatertank.Beginremovingallgranulesfrombaseandwatertank.Usebrushtocleanaroundmembrane.Caution:Donotdisposeofgranulesinsink!Usedgranulesmustgoinwaste!

Q. The directions tell me not to place the unit directly on the floor, why do I have to elevate the unit?

A.Theideawiththisunitistoallowonetoforcehumidityintotheair.Becauseofthis,thecarpetingorwoodfloorsurroundingtheunitmaybecomedamp.Iftheunitis

www.sylvane.com 1-800-934-9194

Page 20: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

20

en placedatleast3feetoffthefloor,themistwillhavetheopportunitytoevaporatebeforehittingthefloor.

Q. Water does not go into the tank.A.Inordertofillthetank,itmustbeturnedupsidedown.Thecartridgeisplacedonthewatertankcap.Donotpourwaterinthetubewhichisthemistoutlet.

Q. White dust is emitted from the unitA.Whitedustparticlesaremineralsthatarebrokenupintinypiecesbytheultrasonicprocess.

Solve the problem:•Soakthedemineralizationcartridgeinabowlofwaterforaminimumof24hours.Ifthecartridgeissoakedinthewatertank,thewaterinthetankandthebaseneedstobereplacedbeforeusingtheunit.

•Exchangethedemineralizationcartridgeafter1­2monthswhenyouuseveryhardwater(forsofterwaterafter2­3months).Nomatterhowhardyourwateris,exchangethecartridgeattheverylatestafter6months.

•Don’tusewaterfromapre­installedwatersoftener,orsodiuminsteadofcalciumwillbeemittedfromtheunit.Usedistilledwaterinsteadandremovethedemi­neralizationcartridge.

•Forveryhardwaterareasuseonlydistilledwaterandremovethedemineralizationcartridge.

•UseReverse­Osmosiswater(R­Owater)insteadofdistilledwaterandremovethedemineralizationcart­ridge.

•Cleaning light is illuminated (digital models) Switchofftheunitandunplugit.Emptythewaterinthebase.Rinsethebasewithhot/cleanwater.Donotsubmergethebase!Visuallyinspectthebasefordirtormineralbuildup.Ifsoftwaterisuseddecalcifyingtheunitevery4weekswithEZCalissuggested.Ifhardwaterisusedtheunitshouldbedecalcifiedevery2weeks.Donotforgettoresetthecleanlightafterreset­tingtheunit.

Q.Reset cleaning light (digital models)A. Thecleaninglightdoesnotautomaticallyreset.Holddownthepowerbutton(buttonAininstructionmanual)untilthelightstopsflashing.Thelightautomaticallycomesonapprox.after14daysofpluggingintheunit.

Q.The hygrometer on unit reads a different humidity level than external hygrometer.

A. Notallhygrometersarecalibratedthesame,andmostareoffby+/­5%.Plusthehumiditylevelisnotthesameinthewholeroom.Theaircirculationisdifferentineverycorneroftheroom.Theunitshouldnotbeplacednearaheatingventoraradiatorastheheatwillabsorballofthemoisture.

Q.Humidity level is not changing or does not reach the desired humidity level.

A. Ifthewatertankneedsrefillingmorethanonceperday,theunitisworkingproperlyandtheclimaticcon­ditionintheroomhasaninfluenceonthehumidity.

Reasons for low humidity level:•aircirculationisveryhigh(airisfullyexchangedse­veraltimesperday–thehumidifierneedstostartsitsworkfromscratch)

• insulationofhome(seeaircirculation)•openspacewithhighceilings(notonlythefootageoftheroomcountsbutalsotheheight)–high­risebuil­dingsrequiremorehumidification.

•openwindows–workssimilartoaircirculation(ifitisverycoldoutsidedon’topenthewindowmorethan2timesperdayfor3minutes)

•bigdifferencebetweenoutsidetemperatureandinsidetemperature–thecoldertheairthelessmoistureitiscapabletoholdandthemoretheairisheateduptheloweristhepercentageofrelativehumidity(=theamountofwatervaporintheair,comparedtotheamounttheaircouldholdifitwastotallysaturated)

•positionoftheunit­ifitisplacedclosetoadoor,win­doworairvent.Thisincreasestheaircirculation.

Q.Tank is leakingA. Checkifthereareanyhairlinecracks.Droppedunitsorwatertanksthatarecrackedwillnotbecoveredunderthewarranty.Pleasecontacttheretailertheunitwaspurchasedfromincaseyourunitarrivesdamaged.

Q.Placing the face in the mistA. Itisnotrecommendedthatanybodyplacestheirfaceinthemist.Itisanelectricalproductandshouldnotbeplayedwith.

Q.No mist / unit is not working / empty indicator keeps flashing

A. Fillupthewatertank.Checkifwaterisflowingthroughthedemineralizationcartridge(attachedtothewatertankcap).Ifthewatertankisfullbutthereisonlylittlewaterinthebaseitindicatesthatthewaterisnowflowingthroughthedemineralizationcartridge.

•Waitfor15minutestoallowthemisttocomeoutoftheunit.

• Iftheunitisnotworkingandtheemptylightisnotflashingyoumighthavesetthedesiredhumiditytoolowandthecurrenthumiditylevelintheroomishig­her.Thatiswhytheunitswitchesoffautomatically.

• Iftheemptyindicatorkeepsflashingandthetankisfull,thewaterisnotflowingthroughthecartridge.Exchangethecartridgeorthegranulesinthecartridgeafter2­3months,inareaswithhardwaterexchangethecartridgeafter1­2months.However,thedemi­neralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore

• Ifthegranulesarenew,seethefollowinginstructions:•Makesurethecartridgeand/orgranulesweresoakedfor24hours,drygranulestakeevenlongerforwatertofilterthroughthecartridgeandintothebase.Next,pleaseremove2tablespoonsofgranulesfromthecartridge,andthrowthemaway.Whentherearetoomanygranulesinthecartridgeitdoesnotallowwatertoflowfromthetanktothebase.

www.sylvane.com 1-800-934-9194

Page 21: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

21

enQ.Water tank cap is too tight to unscrewA. Thiscouldbeacauseoftheairpressurewithinthewatertank.Depressthespringonthebottomofthewatertankcaptoreleaseairfromthewatertank.Continuetodothisuntilyouareabletounscrewthewatertankcap.

Q.Unit is running intermittently.A. Howlonghasitbeensincethecontentsofthecart­ridgewerereplaced?If2­3monthshavepassed,itistimetoreplacethecontentsofthecartridge.Howeverthedemineralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.

• Ifthecontentsofthecartridgewerejustreplacedthereareprobablytoomanygranulesinthecartridge.Re­move2tablespoonsofgranulesfromthecartridge.

Accessories

Q.Do I need to keep any parts before I replace the demineralization cartridge?

A. Yes,alwayskeepthewatertankcap(thisisthepiecethatattachesthedemineralizationcartridgetothewatertank).

Q.What is the Ionic Silver Stick (ISS) and how long is it good for?

A.TheIonicSilverStick(ISS)usestheanti­microbialeffectofsilvertopreventthegrowthofmicrobesinthewaterbase.Itbeginstofunctionassoonasitcomesintocontactwithwater,eveniftheunitisswitchedoff.TheIonicSilverStickshouldbechangedeveryyear.

Q.Placement of the Ionic Silver StickA.Pleaseseepicture28forinstructions.

Q.Replacement reminderA.IneachISSboxandonallthenewproductsthereisanISSlifecycleindicator.Checktheboxofthemonth

whenstartingtousetheISSandwritetheyearonthelineindicated.Exchangeitafteroneyear.

Q.What is EZ Cal?A. ThereisasamplepacketofEZCalincludedinthepackagingofyourhumidifier.EZCalisusedforcleaninganddescalinganyoftheAIR­O­SWISShumidifiersandcleansmineralbuild­up.EZCalistheonlyrecommen­dedcleaninganddescalingsolution.DoNOTuseanyothercleaningsolutionssinceitcandamagethepro­duct.AnyuseofcleaningsolutionsapartfromEZCalwillvoidthewarranty.Instructionsforusingareonthepacket.Onlyuse1packetfor32ozofwater.Donotchangetheratio.Itcanalsobeusedforotherhumi­difierbrands.ThorouglyrinsethebasewithpotablewaterandmakesurenoEZCalresiduesremaininthebase!EZCalisavailableatselectedretailstoresandonlinewww.airoswiss.net.

www.sylvane.com 1-800-934-9194

Page 22: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

22

en

www.sylvane.com 1-800-934-9194

Page 23: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

www.sylvane.com 1-800-934-9194

Page 24: AOS 7145 / 7147 - Sylvane · en Operation AOS 7145 A) On/Off Dial and regulation of mist output Turning the rotary dial clockwise switches the appliance on and at the same time regulates

Please check our website www.airoswiss.net for further information.

AIR-O-SWISS is a registered trademark of PLASTON Group, Switzerland 3648

4-00

www.sylvane.com 1-800-934-9194