en
Important safety instructions• Priortousingtheappliance,readthroughtheinstructionsforcompleteuseandretaininasafeplaceforlaterreference.
• WARNING–OnlyusetheUltrasonicindoorsandwithinthespecifiedtechnicaldata.Improperusecanbehazardousforthehealthandleadtocriticalinjury.
• Connecttheunitonlytoalternatingcurrentwithvoltageaccordingtotheratinglabel.
• Childrencannotrecognizethehazardsassociatedwiththeusageofelectricalappliances.Forthisreason,alwayssupervisechildrenwhentheyarenearthehumidifier(image1).
• Neverusetheapplianceifthereisanydamagetotheapplianceorcable(2),aftermalfunction,aftertheappliancehasbeendropped(3)ordamagedinanyotherway.
• Repairsofelectricalappliancesareonlytobemadebyqualifiedserviceengineers(4).Improperrepairworkcancauseconsiderabledangertotheuser.
• Placethehumidifieronadry,levelsurface(5).• Do not place the appliance directly on the floorornexttoaheatingvent(6).
• Ifthemistcomesincontactwiththefloorpriortoevaporating,thefloorsurfacecanbecomedamaged.Wedonotacceptanyliabilityfordamagesinthecaseofincorrectplacementoftheunit.
• Theunitshouldbeplacedinanelevatedposition(7),e.g.onatable,chestofdrawers,etc.
• Placeappliancewhereitisnoteasilyknockedover(8).• Alwaysunplugwhennotinuse.• Onlyoperatethehumidifierwhenitiscompletelyassembled.
• ALWAYSunplugbeforeremoving/filling/emptyingthewatertank,beforecleaning/maintaining,assembling/dismantlingofindividualpartsandbeforemovingtheappliance.
• Donottouchthewaterinthebaseduringoperationbecauseofhighfrequencyvibrationsinthewater.
• Donotrunpowercordsundercarpets,anddonotcoverwiththrowrugs.Arrangecordsothatitwillnotbetrippedover.
• Neverpulltheplugfromtheoutletbythecableorwithwethands.
• Donotusetheappliancewherecombustiblegasesorvaporsarepresent.
• Donotexposetheappliancetorain,orusenearwater,inabathroom,laundryareaorotherdamplocation.
• Thisunitmustbeusedinitsuprightposition.• Donotallowforeignobjectstoenterventilationorexhaustopeningasthismaycauseelectricshockordamagetotheappliance.Donotblockairoutletsorintakes.
• Donotpourwaterintothemistoutletoftheappliance.• Thisappliancehasapolarizedplug(onebladeiswiderthantheother).Toreduceriskofshock,thisplugisintendedtofitinapolarizedoutletonlyoneway.Iftheplugdoesnotfitfullyintheoutlet,reversetheplug.Ifitstilldoesnotfit,contactaqualifiedelectrician.DONOTattempttodefeatthissafetyfeature.
• Aloosefitbetweentheplug(receptacle)andtheACoutletmaycauseoverheatingandadistortionoftheplug.Contactaqualifiedelectriciantoreplacelooseorwornreceptacles.
• Donotsit,standorplaceanyheavyobjectsontheappliance.
• Donotsubmergethemainbodyinwaterorotherliquids.
• Disconnectpowersupplybeforeservicing.• Personswhoarenotfamiliarwiththeinstructionsforuse,aswellaschildrenandpersonsundertheinfluenceofmedication,alcohol,ordrugsarenotpermittedtooperatetheappliance,orareonlypermittedtooperateitundersupervision.
• Theuseofwateradditives,suchasethereal/essentialoils,fragrances,eucalyptus,waterconditionersetc.,damagesthetankmaterialandasaconsequencethewholeunit.Anyuseofsuchadditiveswillvoidthemanufacturer’swarranty.
• Remark:Neitherhumansnoranimalscanhearthehighfrequencyvibrations.
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!www.sylvane.com 1-800-934-9194
7
en
5
1
3
7
96
2
4
8
www.sylvane.com 1-800-934-9194
8
en ForewordCongratulationsonchoosingtheUltrasonicHumidifierAOS7145/7147fromAIROSWISS!
Didyouknowthatdryroomair:• Causesthemembranesinyourrespiratorysystemtodryout,andalsocauseschappedlipsandstingingeyes?
• Encouragesinfectionsandillnessesofrespiratorysystem?
• Causesweariness,tirednessandpoorconcentration?• Stresseshouseholdpetsandhouseplants?• Encouragestheformationofdustandtheelectrostaticchargingoftextilesmadeofsyntheticfibers,carpetsandplasticflooring?
• Damagesfurnishingsmadeofwoodandparquet?• Detunesmusicalinstruments?
General informationAcomfortableatmosphereindoorsisreachedwitharelativehumidity levelbetween40and60%.Yourhumidifierautomaticallycontrolsthehumiditylevelaccordingtothedesiredsetting.Iftheairistoodry,thehumidifierwillautomaticallyswitchon.Assoonasthedesiredhumiditylevelisreached,itwillswitchoff.
Unpacking• Carefullyremovethehumidifierfromthebox.Placeyourhandsunderneaththeproducttopullitoutofthebox(10).
• Warning:Donottaketheunitoutoftheboxbypullinguponthetankhandlebasemayfallandwillbedamaged(11).
•Removetheplasticbagfromthehumidifier.• Observetheinformationgivenontheratingplateaboutthevoltage.
• Usetheoriginalpackagingforstoringtheapplianceifyoudonotusethehumidifierallyearround.
10
11
www.sylvane.com 1-800-934-9194
9
enDescription of the applianceMistoutlet(rotating)
Evaporationchamber
Watertank
Demineralizationcartridge
Mainbody
Controlpanel
Watertankcap
IonicSilverStick®
PowerPlug
Membrane
Brush
Nebulizerspace
www.sylvane.com 1-800-934-9194
10
en Setting upFindingtheideallocationforyourunit:• Donotplacethehumidifierdirectlynexttoaheatingventoronafloorwithfloorheating.Themoistureofthemistcandamagethefloorsurface(6)(seeSafetyInstructions).
• Theunitshouldbeplacedinanelevatedposition(7),e.g.onatable,chest,etc.atleast3ftoffthefloor.
• Themistoutletmustnotbepointeddirectlyatplants,furniture,orotherobjects(12).Keepdistanceofatleast20inches(50cm).
• Soakthedemineralizationcartridgeinawaterbath24hoursbeforeusingit(13).Thegranuleshavetoabsorbwatertoreachhighperformance.Ifthecartridgeissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.
• Onaveragethedemineralizationcartridgeshouldbereplacedevery2–3monthsdependingonyourwaterhardness.Someareasmayneedtoreplacethecartridgesooner,somemaylastlonger.Thecartridgemustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.
See«Replacementofthedemineralizationcartridge».• Readtheinstructionsunder«FillingtheTank»foraddingwaterinthehumidifier(14and15).
• Placethewatertankontothebase.• Inserttheplugintothesocketandswitchontheapplianceusingtheon/offdial(18and19).
• About10to15minutesafteritisswitchedonthedevicewillreachitsfulloutputlevel.
• Makesurethatthecableisnotpinchedanywhere(9).Donotoperatethehumidifierifthecableisdamaged(2).
12
13
www.sylvane.com 1-800-934-9194
11
en
16
17
15 18
19
14Filling the tankAlways unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!
Do not operate the humidifier when the water tank isempty!When thewater reaches theminimum level, theunitswitchesoffthenebulizerfunctionautomatically.Theemptyindicatorlightcomesonshowingtankisempty.
•Removethewatertankfromthebaseandunscrewthewatertankcap(14).
• Makesurethatnoforeignobjectsareinthewatertank.
• Fillthetankwithclean,coldwaterfromthetap(15).Closethecapofthewatertanksecurely,placethewatertankontothebase(16).Thewaterisnowrunningfromthetankintothebase.
• Donotpourwaterintothemistoutletoftheappliance(17).
• Inserttheplugintothesocket(18)andswitchontheapplianceusingtheon/offdial(19).Theemptyindicatorlightmaystayilluminatedforsomesecondsuntilthebaseisfilledwithwater.
Do not use additivesWater additives (ethereal/essential oils, fragrances,eucalyptus, water conditioners, etc.) must not be used!Evenasmallamountcancausecracksinthematerial.Thematerialisn’tmadefortheuseofsuchadditives.Onedropisenoughtodamagethetankandasaconsequencetheunit.Anyuseofsuchadditiveswillvoidthemanufacturer’swarranty.
www.sylvane.com 1-800-934-9194
12
en Operation AOS 7145
A) On/Off Dial and regulation of mist outputTurning the rotary dial clockwise switches the applianceonandat thesame time regulates themistoutput fromlowtohigh.
B) Hygrostat (setting the humidity level)Thedesiredhumiditylevelcanbesetbyturningtherotaryswitchclockwise.Arelativehumiditybetween40and60%isrecommended.Youcanachievethislevelbyrotatingtheswitchuntilitisroughlyintheverticalposition.Theaccuracyofmeasurement is+/5%.Theunitwill switchoffwhenthemoisturelevelexceedsthedesiredsetting.Theappliancedoesnotswitchoffiftheswitchisturnedalltheway to the right.Thisactivates thecontinuousoperationfunction.
C) Empty indicator (red)Thewaterleveliseasytosee,thankstothetransparentwatertank.Theappliancealsoalertsyouwhenthewatertankisempty.Theredemptyindicatorisilluminated(symbolC).Pleasereadthechapter«Fillingthetank»formoreinformation.TheredsymbolCmaystayilluminatedforsomesecondswitharefilledtankuntilthebaseisfilledwithwater.
A
B
C
www.sylvane.com 1-800-934-9194
13
enOperation AOS 7147
A) On/Off DialYoucanswitchtheunitonoroffbypressingbuttonA.Thisbuttonisalsousedtoresetthecleaningindicatorlight(byholdingdown).
B) Hygrostat (setting the humidity level)BypressingbuttonByoucansetthedesiredhumiditylevelfrom30%to80%orCO(continuousoperation).Arelativehumiditybetween40and60%isrecommended.Theaccuracyofmeasurementis+/5%.Theunitwillswitchoffwhenthemoisturelevelexceedsthedesiredsetting.Duringselectionthetargetvalueisdisplayed(symbol DESIRED).Thedisplaywillautomaticallyshowthecurrentvalueafterafewseconds(symbol CURRENT).
C) TimerUsing button C, the operation time can be set adjustablebetween1and8hoursorCO(continuousoperation).Symbol Gshowstheoperatingperiodthathasbeenset(1h/2h/3h/4h/5h/6h/7h/8h/CO).Thedisplaywillautomaticallyshowthecurrenthumidityafterafewseconds.
D) Mist output (regulating mist output)ByrepeatedlypressingbuttonDyoucancontrolthemistoutput.Symbol H showswhichof the three levels (low/medium/high)youhaveselected.
E) Operation with pre-heating (warm mist)ButtonEisusedforswitchingthepreheatingonandoff(symbol Ilightsup).Asaresult,thewaterispreheatedtoa temperatureof176°F (80 °C) beforeentering thenebulizerspace.Ittakesapprox.10to15minutesforthewater in thebase towarmup.Themistnow leaves thehumidifieratapleasanttemperatureof104°F(40°C).Theadvantageof this is that the roomtemperaturedoesnotdrop and, in addition, it significantly improves thewaterqualitymaintenance.
F) Automatic mode and Sleep modeTheautomaticandsleepmodescanbeactivatedbypressingbuttonF.Bypressingthebuttononce,theautomaticfunctionisswitchedon(symbol Jappearsonthedisplay),maintainingtheoptimumhumiditysubjecttothetemperature.Controltakesplacebymeansofoutputquantityandpresettargetvalue.Bypressingthebuttontwice,thesleepfunctionisswitchedon(symbol Kappearsonthedisplay),thetargethumidityis50–65%;theoperationtimeissetat6hoursandtheheatingisswitchedon.Inaddition,theoutputquantityisalsocontrolledsubjecttothedifferencebetweenthetargetvalueandtheactualvalue.Thehygrostatandmistoutputsettingscannotbechangedineithermode.IfthebuttonsBorDarepressed,theunitwillnolongerbeinautoorsleepmode.
G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Automatic Mode Indicator
K) Sleep Mode Indicator
L) Empty indicatorThewater level iseasytosee,thankstothetransparentwatertank.Theappliancealsoalertsyouwhenthewatertankisempty.Theemptyindicatorisilluminated(symbolL).Pleasereadthechapter«Fillingthetank»formoreinformation.ThesymbolLmaystayilluminatedforsomesecondswitharefilledtankuntilthebaseisfilledwithwater.
M) Cleaning indicatorIfsymbolM«CLEAN»appearsonthedisplay,theapplianceshouldbecleanedasrecommendedbythemanufacturer.Thissymbolcomesonautomaticallyevery2weeks,dependingonthelevelofuse.The display can be reset by holding down button A until the light disappears.
D
E
F
H
I
J
L
A
B
C
G
K
M
www.sylvane.com 1-800-934-9194
14
en
ACID
23
22
21
20Cleaning/Maintenance Always unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!
Caution – risk of electric shock and damage of the product!
• Switchofftheappliance(20)andunplugitfromthesocketbeforecleaningit(21).
• Cleanthewatertankandthebaseregularly.Usewateronly,nodetergents(22).
• UseAIROSWISSEZCalcustomcleaninganddescalingagentonlytoremovedepositsfromthemembraneregularly(23).ThereisasampleofEZCalincludedinthepackagingofyourhumidifier.Instructionsforusingareonthepacket.Onlyuse1packetfor32ozofwater.Donotchangetheratio.DoNOTruntheunitwhenusingEZCal.Thiscancausedamagetotheproductandvoidsthewarranty.ThoroughlyrinsethebasewithpotablewaterafterusingEZCalandmakesurenoEZCalresiduesremaininthebase.
EZCalfromAIROSWISSistheonlyrecommendedcleaninganddescalingsolution.DoNOTuseanyothercleaningsolutionssinceitcandamagetheproduct.AnyuseofcleaningsolutionsapartfromEZCalwillvoidthewarranty.
• Makesuremainbodyisneversubmergedinwater(24)!
• AOS7147:Thecleaningindicatorstillappearsonthedisplayaftercleaning.ToresetitholddowntheON/OFFbuttonuntilthecleanlightdisappears.
• Cleantheinnerpartswithasoftcloth.Donotuseanysolventsoraggressivecleaningagentstocleantheappliance(25).
25
24
www.sylvane.com 1-800-934-9194
15
en• Onlyusethebrushtocleanthemembrane.Thisshouldbedoneonceaweek.Onlyusethesoftbristleportionofthebrush(26).
• Changethewaterinthetankatleastonceaweekifwaterisstandingformorethanaweek.
• Toremovethemistoutlet(27):Twistthemistoutlettoeithertherightortheleft.Alignthearrowonthemistoutletwiththearrowontheringaroundthemistoutlet.Onlyonesetofarrowsonmistoutletandringwillalign.Pulluponthemistoutletoncethearrowsarealigned.
Water quality maintenanceThe IonicSilverStick (ISS)uses theantimicrobialeffectof silver toprevent thegrowthofmicrobes in thewaterbase.Itbeginstofunctionassoonasitcomesintocontactwithwater,eveniftheunitisswitchedoff.TheIonicSilverStickshouldbechangedeveryyear.Lookatpicture28forthepositionoftheISSinthebasepartoftheunit.Donottouchthewaterinthebaseduringoperation!Switchofftheunitfirst.Contactyourlocalretailerorcheckourwebsitewww.airoswiss.netforreorderinformation.TheIonicSilverStick®comeswithametallicclipwhichcanberemovedfortheplacementinthisproducttype.
Lifecycle IndicatorYourappliancecomeswithalifecycleindicatorforchangingtheIonicSilverStick®.ToremindyourselfofwhenyouputtheISSintooperation,pleasecrossthecurrentmonthonthestampandwritethecurrentyearonthelineprovided(29).
26
28
29
27
www.sylvane.com 1-800-934-9194
16
en 30
31
•Turntheplasticcupandcartridgeoverandshakeuntilallgranulesareinthecartridge(37).
•Removetheplasticcupandthepinkstyrofoampiecefromthecartridge(38)andretainforfutureuse(therefillgranulesconsistsof3refillbags)(39).
•Closethecartridge(40).•Soakthedemineralizationcartridgeinawaterbath 24hoursbeforeusingit(43).Thegranuleshavetoabsorbwatertoreachhighperformance.Ifthecartridgeissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(44).•Screwthecartridgeonthebottomsideofthewatertank,putthetankonthemainbody(45).
Placinggranules in thecenterof thecartridgeallowsthemtoescapeintheunitortoclogtheunit.Theunitwillnolongeroperateproperlyandthegranulesneedtobecleanedoutthoroughly.
Option B: replace the whole cartridge•Removethewatertankfromthebaseandunscrewthewatertankcap(30).
•Thedemineralizationcartridgeisattachedtothetankcap.Unscrewthecartridgefromthecapbyturningitcounterclockwise(31).Important:doNOTdisposeofthewatertankcap!
• Throwthewholecartridgeintothewaste(41).•Unpackthenewcartridge(42).•Soakthedemineralizationcartridgeinawaterbath24hoursbeforeusingit(43).Thegranuleshavetoabsorbwatertoreachhighperformance.Ifthecartridgeissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(44).Closetankcapwellandplacethetankonthemainbody(45).
Replacement of the demineralization cartridge
Always unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!
Thewater tank is equippedwith a demineralization cartridge.Thiscartridgehastobereplacedevery2–3months.Ifthewaterisveryhard,itmaybenecessarytoreplacethecartridgeearlier.Whitedustaroundthedeviceisasuresignthatthecartridgeneedsreplacing.Ifwhiteresiduestillformsaroundthedeviceafteranewcartridgehasbeeninserted,pleasemakesurethatthewateryouareusingisuntreated.Ifthewaterflowsthroughadecalcificationsystem–suchasanionexchanger–(sodiumisaddedtoremovecalcium)inthebuildingbeforeitisusedinthehumidifier,saltcanprecipitateaswhitedustaroundthedevice.Thedemineralizationcartridge or the granulesmust be exchangedat the latestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.
Option A: replace the granules•Removethewatertankfromthebaseandunscrewthewatertankcap(30).
•Thedemineralizationcartridgeisattachedtothetankcap.Unscrewthecartridgefromthecapbyturningitcounterclockwise(31).Important:doNOTdisposeofthewatertankcap!
•Openthecartridge(32).•Throwthecontentintothewaste(Attention!Disposedgranulescanmakethefloorslippery!)(33).
•Placetheenclosedpinkstyrofoampieceinthecenterofthecartridge.Donotpushittothebottomasitwillbedifficulttoremoveafterwards(34).
•Pourthecontentsofonerefillgranulesbagintotheplasticcupthatisincludedwiththerefillgranulespackaging(35).
•Placetheemptycartridgewiththepluginthecenterontotheplasticcup(36).
32 33
www.sylvane.com 1-800-934-9194
17
en
44
34 35
36
37
38
39
41
43
40
42 45
www.sylvane.com 1-800-934-9194
18
en Storing the appliance for extended periodsCleantheapplianceasdescribedearlierandallowtodrythoroughly.Preferablystoretheapplianceinitsoriginalbox,inadryplaceawayfromhightemperatures.
Legal noticeThehumidifieriscULlisted.Subject to technicalchange.The instructions foruseareprotectedbycopyright©PLASTONAG.
AccessoriesContact your local retailer or check our website www.airoswiss.netforreorderinformation.
Customer ServiceCustomerService(USA)18003360326www.airoswiss.net
Technical data AOS 7145
Electricalvoltage 120V/60HzPowerconsumptionupto 45WHumidityoutputupto 3gallons/24hSuitableforroomsupto 600sqft/55m2
Dimensions(LxWxH) 9.5x10.3x12.2in 24x26x31cmWeight(empty) 6.6lbs/3kgAccessories Demineralizationcartridge IonicSilverStick®
Technical data AOS 7147
Electricalvoltage 120V/60HzPowerconsumptionupto 40W/(125W*)Humidityoutputupto 3.5gallons/24h*Suitableforroomsupto 650sqft/60m2
Dimensions(LxWxH) 9.5x10.3x12.2in 24x26x31cmWeight(empty) 6.6lbs/3kgAccessories Demineralizationcartridge IonicSilverStick®
*whenusedwithpreheatingto176°F(80°C)
Troubleshooting
Problem Possible cause What to do
Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable
Nowaterinthetank(Emptyindicatoron) Filltankwithwaterandwait10min.
Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCal
Demineralizationcartridgeexhausted Replacecartridgeorgranules
Demineralizationcartridgeoverfilled Takeout2tablespoonsofgranulesandthrow withgranules themaway
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min. thehumidifierwillworkproperlyagain
Mineraldepositsonmembrane CleanmembraneusingEZCalandbrush
Unitrunningintermittently
Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Replacedemineralizationcartridgeorgranules
www.sylvane.com 1-800-934-9194
19
enGeneral Humidifier Questions
Q.Why isn’t there enough moisture in my room?A. Howoftendoyouruntheunit?Iftheunitisonlyrunatnight,thenduringthedaythemoisturelevelwilldropifmoistureisnotconstantlyaddedtotheair.
Q.Do you leave your door open or closed when the unit is running?
A. a) Byleavingthedooropen,thisallowsmoisturetoleavetheroomandgointootherareasofthehouse.Ifyouwouldlikethemoisturetostaywithinonespecificroomyoushouldconsiderclosingthedoorwhiletheunitisrunning.
A. b)Wood,leather,carpet,curtains,andothertypesoffabricsoakupalotofmoisture,thusnotleavingenoughmoisturefortheair.Ifthewindowisleftopen,thenthisallowsmoisturetoescapetheroom.Anotherfactorisalotoftimestheunitisplacednexttoaheatingdevice.Theideaisthattheairblowingintotheroomwillquicklyplacemoisturearoundtheroom.Unfortunately,thisconceptdoesnotworkbecausethehotaircomingoutofaventwillsoakupmostofthemoisture,andnoneoftheairwithintheroomwillreceiveany.
Q.How much moisture do I need in my room?A. Suggestedhumiditylevelsarebetween40–60%.
Q.What are the effects of too little or too much humidity?
A. Dryaircancausedryskin,staticelectricity,outoftunemusicalinstruments,increasedlevelsofdust(dryaircausesdusttorise),damagetowoodenobjects(dryoutandeventuallycracksappear),discomfort,sickness,anddriesoutnasalmembranes.
Overhumidifyingtheaircancausemoldandwallpapertopeel.
Q.Why do I need a humidifier when I can just open my window?
A. Themoisturelevelwithintheoutsideairisnothighenoughtohumidifyaroom.Thecoldertheairthelessmoistureitiscapabletohold,andthemoretheairisheatedupthepercentageofrelativehumidityislower.Relativehumiditymeanstheamountofwatervaporintheair,comparedtotheamounttheaircouldholdifitwastotallysaturated.Thedifferenceishigherbetweenoutsideandinsidetemperatures;morehumidificationisneededbecauseofthedryairintheroom.
Q.Where should I place my humidifier?A. Theunitshouldbefreestandingandnotclosetoawall,window,door,orthermalbridgesothatairmaycirculatearoundtheunit.
Ultrasonic Frequent Questions
Q.Why does it say open/close on the demineralization cartridge cap?
A. Thosedirectionsarethereincaseyoudecidetousetherefilloptiontoreplacethegranules;thepurposeisforhowtoopenandclosethecap.Ifyoudidopenthecapbeforeplacingitinthewatertank,youwillmostlikelynoticethattherearegranulesinthewatertankandthebaseoftheunit.Immediatelyturnofftheunit,andemptythewateroutofthebaseandthewatertank.Beginremovingallgranulesfrombaseandwatertank.Usebrushtocleanaroundmembrane.Caution:Donotdisposeofgranulesinsink!Usedgranulesmustgoinwaste!
Q. I just replaced my cartridge, and the contents and water in the base has turned a blue-green color.
A. Thissometimesoccurswhenthecartridge,oreventhegranules,arereplaced.Thisdoesnotoccurwithallreplacementcartridgesorgranules,andisareactionofwatercontentandtheUltrasonicvibrations.Thisisnotanindicatortoreplacethecartridge.
Q.There is no fill-line on the water tank, how far may I fill it up?
A. Thereisnofilllineonthewatertank,anditmaybefilledallthewaytothetop.
Q.What is the purpose of the demineralization cart-ridge (DMC)?
A. TheDMCremovesmineralsfromthewatertopreventwhitedust.Thecontentsofthecartridgeneedtobesoakedfor24hrspriortofirstusingtheunitsothattheymayfullyexpandandremovemineralsfromthewater.ThecontentsoftheDMChavealifeof2–3months.Thecartridgemayneedtobereplacedmoreoftendependingonwaterhardnessandhowoftentheunitisused.AnindicationofwhentheDMCneedstobechangedcanbewhitedustorreducedamountofmistoutput.
Q. Is it ok to use distilled water with the unit?A. Forbestresultswithyourultrasonichumidifierusedistilledorreverseosmosiswaterandremovethedemineralizationcartridge.
Q. I just replaced the contents of the cartridge and now have granules everywhere.
A. First,makesuretherearenogranulesinthemiddleofthecartridge.PlacinggranulesinthemiddleoftheDMCallowsthemtoescapeintheunit.Immediatelyturnofftheunit,andemptythewateroutofthebaseandthewatertank.Beginremovingallgranulesfrombaseandwatertank.Usebrushtocleanaroundmembrane.Caution:Donotdisposeofgranulesinsink!Usedgranulesmustgoinwaste!
Q. The directions tell me not to place the unit directly on the floor, why do I have to elevate the unit?
A.Theideawiththisunitistoallowonetoforcehumidityintotheair.Becauseofthis,thecarpetingorwoodfloorsurroundingtheunitmaybecomedamp.Iftheunitis
www.sylvane.com 1-800-934-9194
20
en placedatleast3feetoffthefloor,themistwillhavetheopportunitytoevaporatebeforehittingthefloor.
Q. Water does not go into the tank.A.Inordertofillthetank,itmustbeturnedupsidedown.Thecartridgeisplacedonthewatertankcap.Donotpourwaterinthetubewhichisthemistoutlet.
Q. White dust is emitted from the unitA.Whitedustparticlesaremineralsthatarebrokenupintinypiecesbytheultrasonicprocess.
Solve the problem:•Soakthedemineralizationcartridgeinabowlofwaterforaminimumof24hours.Ifthecartridgeissoakedinthewatertank,thewaterinthetankandthebaseneedstobereplacedbeforeusingtheunit.
•Exchangethedemineralizationcartridgeafter12monthswhenyouuseveryhardwater(forsofterwaterafter23months).Nomatterhowhardyourwateris,exchangethecartridgeattheverylatestafter6months.
•Don’tusewaterfromapreinstalledwatersoftener,orsodiuminsteadofcalciumwillbeemittedfromtheunit.Usedistilledwaterinsteadandremovethedemineralizationcartridge.
•Forveryhardwaterareasuseonlydistilledwaterandremovethedemineralizationcartridge.
•UseReverseOsmosiswater(ROwater)insteadofdistilledwaterandremovethedemineralizationcartridge.
•Cleaning light is illuminated (digital models) Switchofftheunitandunplugit.Emptythewaterinthebase.Rinsethebasewithhot/cleanwater.Donotsubmergethebase!Visuallyinspectthebasefordirtormineralbuildup.Ifsoftwaterisuseddecalcifyingtheunitevery4weekswithEZCalissuggested.Ifhardwaterisusedtheunitshouldbedecalcifiedevery2weeks.Donotforgettoresetthecleanlightafterresettingtheunit.
Q.Reset cleaning light (digital models)A. Thecleaninglightdoesnotautomaticallyreset.Holddownthepowerbutton(buttonAininstructionmanual)untilthelightstopsflashing.Thelightautomaticallycomesonapprox.after14daysofpluggingintheunit.
Q.The hygrometer on unit reads a different humidity level than external hygrometer.
A. Notallhygrometersarecalibratedthesame,andmostareoffby+/5%.Plusthehumiditylevelisnotthesameinthewholeroom.Theaircirculationisdifferentineverycorneroftheroom.Theunitshouldnotbeplacednearaheatingventoraradiatorastheheatwillabsorballofthemoisture.
Q.Humidity level is not changing or does not reach the desired humidity level.
A. Ifthewatertankneedsrefillingmorethanonceperday,theunitisworkingproperlyandtheclimaticconditionintheroomhasaninfluenceonthehumidity.
Reasons for low humidity level:•aircirculationisveryhigh(airisfullyexchangedseveraltimesperday–thehumidifierneedstostartsitsworkfromscratch)
• insulationofhome(seeaircirculation)•openspacewithhighceilings(notonlythefootageoftheroomcountsbutalsotheheight)–highrisebuildingsrequiremorehumidification.
•openwindows–workssimilartoaircirculation(ifitisverycoldoutsidedon’topenthewindowmorethan2timesperdayfor3minutes)
•bigdifferencebetweenoutsidetemperatureandinsidetemperature–thecoldertheairthelessmoistureitiscapabletoholdandthemoretheairisheateduptheloweristhepercentageofrelativehumidity(=theamountofwatervaporintheair,comparedtotheamounttheaircouldholdifitwastotallysaturated)
•positionoftheunitifitisplacedclosetoadoor,windoworairvent.Thisincreasestheaircirculation.
Q.Tank is leakingA. Checkifthereareanyhairlinecracks.Droppedunitsorwatertanksthatarecrackedwillnotbecoveredunderthewarranty.Pleasecontacttheretailertheunitwaspurchasedfromincaseyourunitarrivesdamaged.
Q.Placing the face in the mistA. Itisnotrecommendedthatanybodyplacestheirfaceinthemist.Itisanelectricalproductandshouldnotbeplayedwith.
Q.No mist / unit is not working / empty indicator keeps flashing
A. Fillupthewatertank.Checkifwaterisflowingthroughthedemineralizationcartridge(attachedtothewatertankcap).Ifthewatertankisfullbutthereisonlylittlewaterinthebaseitindicatesthatthewaterisnowflowingthroughthedemineralizationcartridge.
•Waitfor15minutestoallowthemisttocomeoutoftheunit.
• Iftheunitisnotworkingandtheemptylightisnotflashingyoumighthavesetthedesiredhumiditytoolowandthecurrenthumiditylevelintheroomishigher.Thatiswhytheunitswitchesoffautomatically.
• Iftheemptyindicatorkeepsflashingandthetankisfull,thewaterisnotflowingthroughthecartridge.Exchangethecartridgeorthegranulesinthecartridgeafter23months,inareaswithhardwaterexchangethecartridgeafter12months.However,thedemineralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore
• Ifthegranulesarenew,seethefollowinginstructions:•Makesurethecartridgeand/orgranulesweresoakedfor24hours,drygranulestakeevenlongerforwatertofilterthroughthecartridgeandintothebase.Next,pleaseremove2tablespoonsofgranulesfromthecartridge,andthrowthemaway.Whentherearetoomanygranulesinthecartridgeitdoesnotallowwatertoflowfromthetanktothebase.
www.sylvane.com 1-800-934-9194
21
enQ.Water tank cap is too tight to unscrewA. Thiscouldbeacauseoftheairpressurewithinthewatertank.Depressthespringonthebottomofthewatertankcaptoreleaseairfromthewatertank.Continuetodothisuntilyouareabletounscrewthewatertankcap.
Q.Unit is running intermittently.A. Howlonghasitbeensincethecontentsofthecartridgewerereplaced?If23monthshavepassed,itistimetoreplacethecontentsofthecartridge.Howeverthedemineralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.
• Ifthecontentsofthecartridgewerejustreplacedthereareprobablytoomanygranulesinthecartridge.Remove2tablespoonsofgranulesfromthecartridge.
Accessories
Q.Do I need to keep any parts before I replace the demineralization cartridge?
A. Yes,alwayskeepthewatertankcap(thisisthepiecethatattachesthedemineralizationcartridgetothewatertank).
Q.What is the Ionic Silver Stick (ISS) and how long is it good for?
A.TheIonicSilverStick(ISS)usestheantimicrobialeffectofsilvertopreventthegrowthofmicrobesinthewaterbase.Itbeginstofunctionassoonasitcomesintocontactwithwater,eveniftheunitisswitchedoff.TheIonicSilverStickshouldbechangedeveryyear.
Q.Placement of the Ionic Silver StickA.Pleaseseepicture28forinstructions.
Q.Replacement reminderA.IneachISSboxandonallthenewproductsthereisanISSlifecycleindicator.Checktheboxofthemonth
whenstartingtousetheISSandwritetheyearonthelineindicated.Exchangeitafteroneyear.
Q.What is EZ Cal?A. ThereisasamplepacketofEZCalincludedinthepackagingofyourhumidifier.EZCalisusedforcleaninganddescalinganyoftheAIROSWISShumidifiersandcleansmineralbuildup.EZCalistheonlyrecommendedcleaninganddescalingsolution.DoNOTuseanyothercleaningsolutionssinceitcandamagetheproduct.AnyuseofcleaningsolutionsapartfromEZCalwillvoidthewarranty.Instructionsforusingareonthepacket.Onlyuse1packetfor32ozofwater.Donotchangetheratio.Itcanalsobeusedforotherhumidifierbrands.ThorouglyrinsethebasewithpotablewaterandmakesurenoEZCalresiduesremaininthebase!EZCalisavailableatselectedretailstoresandonlinewww.airoswiss.net.
www.sylvane.com 1-800-934-9194
22
en
www.sylvane.com 1-800-934-9194
www.sylvane.com 1-800-934-9194
Please check our website www.airoswiss.net for further information.
AIR-O-SWISS is a registered trademark of PLASTON Group, Switzerland 3648
4-00
www.sylvane.com 1-800-934-9194