A PRODUCT OF E-LABS EL AM-101 EL AM-101 ANNUNCIATION MODULES ANNUNCIATION MODULES Contact us: TEL : 042-5884232 Fax : 042-5868145 Email : [email protected] URL : www.epesol.com EPESOL (Pvt) Ltd HIGHLIGHTING FEATURES: í í í í í í í í í í í í í í í Self-contained microprocessor based multi channel alarm annunciator unit 16 contact operated on/off alarm Multiple LEDs for visual alarm indication for each window provide redundancy Alarm channels activated by normally open or normally closed contact Compact Design, highly reliable, allows incorporation of custom changes with ease Meets IEC 60255-5 Ratings Alarm Display windows selection available Voltage type selection option available (AC or DC) Long life super bright multiple LEDs installed in each window to ensure long maintenance free period Input voltage selection range available Lamp test input available An output to actuate audible alarm (buzzer / Hooter) Alarm acknowledge input Highly reliable switch mode power supply to accommodate wide range of AC or DC voltage. Composed of three modules (Annunciation, I/O module, power module) mounted on a single PCB 8 8 Protection: Accessories: ï ï ï Over voltage Mounting screws Floor Stand INTRODUCTION: EL AM-101 is highly reliable microprocessor based annunciator unit that is used in Power Plants, Grid Station, Substations & industrial Panels for providing supervisory control The general purpose is to provide supervision in the process occurring in IPPs, Grid Stations, industries & to generate an alarm for any abnormal condition by illuminating respecting LED based window, common audible alarm by using any audible device (bell, hooter, siren) OPERATION CRITERIA: The annunciation event is indicated by the input signal changing from low to high voltage level. Each event has a dedicated display Window with user Defined text message written on it. AM-101can be modified to handle different input signal voltage levels.Contrary to conventional annunciator AM-101 is equipped in For illuminating the display windows the light bulbs have been replaced by longer life super bright LEDs, thus practically eliminating the need of frequent bulb replacement. In order to distinguish between noise signals & fault signals, it takes 200m sec to annunciate fault window & actuate the audible alarm. NOTE: DISTANCE RELAY SET-A TRIPPED DISTANCE RELAY SET-B TRIPPED LINE OC & EF RELAY TRIPPED 50BF DIRECT TRIP SEND CB + Q1 50BF TRIP CB + Q1 TRIP R3 PANEL LOR(s) OUT OF SERVICE CB + Q3 TRIP R4 PANEL LOR(s) OUT OF SERVICE CB + Q2 TRIP R5 PANEL LOR(s) OUT OF SERVICE R1 PANEL LOR(s) OUT OF SERVICE R6 PANEL LOR(s) OUT OF SERVICE CB + Q3 50BF TRIP CB + Q2 50BF TRIP 132 kV CB TRIP

description

effective material for alarms.annunciations, signals.

Transcript of Annunciator s

Page 1: Annunciator s

A PRODUCT OF

E-LABS

EL AM-101EL AM-101

ANNUNCIATION MODULESANNUNCIATION MODULES

Contact us:

TEL : 042-5884232 Fax : 042-5868145Email : [email protected] URL : www.epesol.com

EPESOL (Pvt) Ltd

HIGHLIGHTING FEATURES:�

Self-contained microprocessor based multi channelalarm annunciator unit

16 contact operated on/off alarmMultiple LEDs for visual alarm indication for eachwindow provide redundancyAlarm channels activated by normally open ornormally closed contact

Compact Design, highly reliable, allowsincorporation of custom changes with ease

Meets IEC 60255-5 RatingsAlarm Display windows selection availableVoltage type selection option available (AC or DC)Long life super bright multiple LEDs installed ineach window to ensure long maintenance free periodInput voltage selection range availableLamp test input availableAn output to actuate audible alarm (buzzer / Hooter)Alarm acknowledge input

Highly reliable switch mode power supply to

accommodate wide range ofAC or DC voltage.

Composed of three modules (Annunciation, I/O

module, power module) mounted on a single PCB

Protection:

Accessories:

Over voltage

Mounting screwsFloor Stand

INTRODUCTION:EL AM-101 is highly reliable microprocessor basedannunciator unit that is used in Power Plants, Grid Station,Substations & industrial Panels for providing supervisorycontrolThe general purpose is to provide supervision in theprocess occurring in IPPs, Grid Stations, industries & togenerate an alarm for any abnormal condition byilluminating respecting LED based window, commonaudible alarm by using any audible device (bell, hooter,siren)

OPERATION CRITERIA:The annunciation event is indicated by the input signalchanging from low to high voltage level. Each event has adedicated display Window with user Defined text messagewritten on it. AM-101can be modified to handle differentinput signal voltage levels.Contrary to conventionalannunciator AM-101 is equipped in For illuminating thedisplay windows the light bulbs have been replaced bylonger life super bright LEDs, thus practically eliminatingthe need of frequent bulb replacement.

In order to distinguish between noise signals &fault signals, it takes 200m sec to annunciate fault window& actuate the audible alarm.

NOTE:

��������������� �������

��������������� �������

�������������������

����������������

������������

��������

����������������������

��������

����������������������

��������

����������������������

����������������������

���������������������

������������

������������

���!������

Page 2: Annunciator s

TS101TS101EL AM-101EL AM-101

Number of fault windows selectionOperating Voltage selectionCasing SelectionLEDs color selectionFault window initiation on pickup or dropoutFault window flash rate selectionFault window input voltage selectionHooter silence independent input selection

For all available optional features please seethe “Specifications” section on next page.

OPTIONAL PARAMETERS

Utility & Communications

Manufacturing:

Power HousesPower SubstationsProtection and Control SystemsMicrowave Relay SitesSwitchgears control

Control signaling of the processAlarm Systems

Commercial:

Alarm SystemsSolar Systems control signalingUninterruptible power SystemsDC Control Systems

APPLICATIONS

A Product of ELABSEP SOL (Pvt) Ltd

ELECTRICAL POWER ENGINEERING SOLUTIONS

����������������

������������

��������

����������������������

��������������� �������

���!������

����������������������

����������������������

������������

��������

����������������������

���������������������

������������

��������

����������������������

����

MOUNTING & DIMENSIONS

��������������� �������

��������������� �������

�������������������

����������������

������������

��������

��������

��������

����������������������

������������

������������

���!������

150

110

10 155

130

FRONT VEIW SIDE VEIW TOP VIEW

Page 3: Annunciator s

EL AM-101EL AM-101

A Product of ELABS

SPECIFICATIONS

Power Supply:

Input Voltage/ Frequency:

Display Windows:

Single Phase:

Output Power:

Numbers:

Lighting devices:

Flash Rate:

100 Vac to 275 Vac @ 50Hz / 60Hz (STM)100 Vdc to 375 Vdc (STM)Customized (SPMs)

25 Watts (STM)

8 or 12 (STM)4 or 6 (SPMs)

LEDs of amber color (STM)LEDs of red, yellow, green, blue and white

(SPMs)3 different color LEDs in a single window, thecolor selection can be done through field (SPMs)

40 flashes per minute (STM)Variable flash rate where flash frequency changesin case of fault persistence and fast events.(SPMs)

Pickup:

Temperature:

Relative Humidity:

Power Consumption:

Input Voltage:

Input Voltage:

Inputs change from Low to high (STM)

Inputs change from High to low (SPMs)

-100C to 550C (STM)

100% (STM)

10 Watts approx (STM)

Universal type input AC or DC (STM)

100 Vac to 275 Vac or 100 Vdc to 375 Vdc (SPMs)

137mm x 97 mm independent of no. of windows

Environmental:

Fault Signals:

Panel Cutout:

STM Standard ModelSPMs Special Models

THEORY OF OPERATION:

Due to the flexible architecture, all the standard sequencescan be incorporated. The basic function of anAM-101 is todetect faults or events at its inputs, (terminated outside thecase) and indicate that, by flashing pertinent windows,followed byACKNOWLEDGE, and RESET etc

Once an input is energized, the lights on the relevantwindow start flashing and the hooter comes on. Theduration of flash rate is sufficient for the inscription ofthe function to be read easilyOn pressing the ACKNOWLEDGE button, theindication flashing will be stopped, and light on thefault window will be kept ON continuously. If faultsignal is removed before the RESET push button ispressed, the window starts flashing again.But in a special model under above scenario the flashrate will be half of the initial flash rate, to indicate theremoval of fault

The RESET is then pressed to extinguish the windowLEDsIn case of persistence of fault, the window shallcontinue to stay lit even when the reset button ispressed.If another fault is energized before having the previousevent cleared the scheme re-functions the same way asdescribed above.The LAMP TEST push button is pressed (whenrequired) to test all window LEDs by lighting themsimultaneously

�Others:�

Independent hooter reset input available other thanavailable in STMACKNOWLEDGE, RESET and LAMP TEST inputsavailable in STM, a separate independent input forhooter silence operation is available in SPMs.Built-in memory to display the order of occurrence ofevents (SPMs).

EP SOL (Pvt) Ltd

ELECTRICAL POWER ENGINEERING SOLUTIONS

Page 4: Annunciator s

EL AM-101EL AM-101

�� For other NON - LISTED/Optional requirement, please contact factory.

8-Windows 12-Windows 16-Windows Size

Single Window

Overall size

Dimensions:

71-B Garden Block New Garden Town Lahore

TEL:+92 42 588 4232 FAX-+92 42 586 8145Email: URL: [email protected]

EP SOL (Pvt) Ltd

ELECTRICAL POWER ENGINEERING SOLUTIONS

MODEL DEFINITION (ORDERING) :

AM 101 - - - -- - -* * ** ** ** * **

Base Unit / Model

A

D

1

2

3

N

L

H

0

1

2

Input Volt Level to power up fault windows A

B

C

1

2

Input Frequency

Input Volts

No. of Annunciation windows

Input Volt Level to power up annunciator

Control Arrangement

Special Model00

01(Consult factory for listed special

models / options)

DC Operated

50Hz

60Hz

AC Voltage

DC Voltage

8- Windows

12- Windows16- WindowsUser Defined

24V DC

48V DC

Universal (AC / DC )

24V DC

48V DC

Control Facility on TB

Control Facility on Front

Standard model

Customized order

Universal (AC / DC)

E - LABS