  • INTRODUCTION TONON DESTRUCTIVE EXAMINATION

  • OUTLINE

    MATERIAL TESTING

    OVERVIEW OF FOUR NDE METHODS Liquid Penetrant Testing (PT)

    Magnetic Particle Testing (MT)

    Radiography Testing (RT)

    Ultrasonic Testing (UT)

    APPLICATION OF NDE

  • Material Testing Material testing is the technology of assessing the soundness and

    acceptability of an actual component with or without affecting thefunctional properties of either test specimen or actual job.

    MATERIAL TESTING

    Destructive Non-destructive

    Tensile testing Radiography testing

    Compression testing Ultrasonic testing

    Impact testing Magnetic particle testing

    Fatigue testing Liquid penetrant testing

    Creep testing Eddy current testing

    Bend testing Acoustic emission testing

    Micro/Macro testing Neutron radiography testing

    Chemical testing etc Thermography etc

  • Material TestingMATERIAL TESTING

    Destructive Non-destructive

    Measure accurate or specific

    characteristics of materials by

    destroying the specimen

    Monitoring and maintaining

    material quality, components

    reliability & systems safety

    without destroying actual job.

    UTS Surface & Subsurface flaws

    Proof stress Coating & plating thickness

    % Elongation Sorting

    % Reduction area Velocity & thickness monitor

    Youngs modulus Structure and assembly evaluation

    Fatigue strength Reliable life assessment etc..

    Creep strength

    Fatigue properties etc

  • DEFINITION OF N.D.E.:

    NDE is a tool, which uses inspection technology to determinesoundness & measurement of characteristics of the rawmaterial, components, structure & equipments etc. withoutcausing harm to them.

    Material Testing

  • Material Testing

    TYPE OF INDICATION: False Indication: Indication, that occurs due to incorrect processing or

    incorrect procedure.

    Non-relevant Indication: It is an indication, which has no relation tothe discontinuity. i.e. Code has given various sizes of indications whichare not be considered as relevant indication.

    Relevant Indication: It is the indication that needs to be evaluated forserviceability and can either be determined as discontinuity or defect.i.e. A indication that may or may not be acceptable by reference codesection.

  • Material Testing

    DISCONTINUITY & DEFECT: Discontinuity: It is any local variation in material continuity which may

    not interfere to its intended service life. E.g. Change in geometry,presence of holes, cavities or inclusions.

    Defect: When any discontinuity, single or multiple, is of such size,shape, type and location, that it can create a substantial failure ofmaterial in its intended service, is known as DEFECT.

    Remember: Every discontinuity is not a defect, Every defect is adiscontinuity.

  • Methods of N.D.E. Visual Inspection (VT)

    Liquid Penetrant Testing (PT)

    Magnetic Particle Testing (MT)

    Radiographic Testing (RT)

    Ultrasonic Testing (UT)

    Eddy Current Testing (ET)

    Leak Testing (LT)

    Acoustic Emission Testing (AET)

    Infrared Thermal Testing (IRT)

    Remote Field Testing (RFT)

    Nuclear Radiographic Testing (NRT)

  • Common Methods used in N.D.E.

    Visual Testing (VT)

    Liquid Penetrant Testing (PT)

    Magnetic Particle Testing (MT)

    Radiographic Testing (RT)

    Ultrasonic Testing (UT)

  • INTRODUCTION TOLIQUID PENETRANT TESTING

  • OUTLINE Introduction & Working principle

    Basic operation procedure of PT

    Materials used in PT

    Classification of PT

    Application of PT

    Types of defects detected by PT

    Advantages & Limitations of PT

    Code Acceptance criteria

    PT in Boiler

    LIQUID PENETRANT TESTING (PT)

  • LIQUID PENETRANT TESTING (PT)

    INTRODUCTION:

    PT is a common method used to detect surface breaking flaws.

    Flaws are detected by bleed-out of a colored or fluorescent dye fromit.

    The technique is based on ability of a liquid to be drawn into a cleansurface breaking flaw by capillary action.

    After a period of time called the dwell, excess surface penetrant isremoved and a developer applied. This acts as a blotter.

    Visible color contrast penetrants require day-light or hand bulb.

    Fluorescent penetrants need to be used in darkened area with anultraviolet "black light".

  • LIQUID PENETRANT TESTING (PT)

    INTRODUCTION (CONT.):

    PT produces a flaw indication that is much larger and easier than flawfor the eye to detect.

    PT produces a flaw indication with a high level of contrast between theindication and the background also helping to make the indicationmore easily seen.

  • LIQUID PENETRANT TESTING (PT)

    WORKING PRINCIPLE:

    FLUORESCENT PT

    VISIBLE PT

  • LIQUID PENETRANT TESTING (PT) BASIC OPERATION PROCEDURE OF PT:

    Surface preparation (Pre-cleaning): The surface must be free of oil,grease, dust, rust and other contaminants that may prevent penetrantfrom entering flaws. Sometimes, test surface may also requiremachining, sand or grit blasting, grinding, buffing etc.

    SOLVENT CLEANING

  • LIQUID PENETRANT TESTING (PT) BASIC OPERATION PROCEDURE OF PT (CONT.)

    Penetrant application: Penetrant can be applied by spraying,brushing, wiping, or dipping the part in a penetrant bath.

    DYE APPLICATION BY BRUSHING DYE APPLICATION BY SPRAYING

  • LIQUID PENETRANT TESTING (PT) BASIC OPERATION PROCEDURE OF PT (CONT.)

    Penetrant dwell time (PDT): The penetrant is left on the surface for asufficient time to allow penetrant to be drawn into a defect. PDT areas recommended by manufacturers or as per written procedure beingfollowed.

    Excess penetrant removal: This step is most delicate. Depending upontype of penetrant used, step may involve cleaning by emulsifier,rinsing with water, solvent remover.

    EXCESS PENETRANT REMOVAL BY SOLVENT EXCESS PENETRANT REMOVED

  • LIQUID PENETRANT TESTING (PT) BASIC OPERATION PROCEDURE OF PT(CONT.)

    Developer application: A thin & uniform layer of developer is appliedto drag out penetrant trapped in the flaw. Developer may be appliedby Spraying, dusting, or dipping.

    DEVELOPER APPLICATION BY SPRAYING

    Slide 17

  • LIQUID PENETRANT TESTING (PT) BASIC OPERATION PROCEDURE OF PT (CONT.)

    Developer dwell time (DDT): The developer is left on the surface for asufficient time to allow it to extract the penetrant out from thediscontinuity. It is usually 10 mins as recommended by themanufacturer or written procedure.

    Interpretation/Evaluation: After passing developing dwell timeinspection is performed under required lighting conditions.

    Post-cleaning: Last step of the inspection process is to clean theresidual penetrant material from the test surface.

    EVALUATION

  • LIQUID PENETRANT TESTING (PT) MATERIALS & EQUIPMENTS USED IN PT:

    Cleaner (Solvent remover)

    Penetrant (Dye)

    Developer

    Lint free cotton cloth

    Emulsifier (Lipophilic or Hydrophilic)*

    Black light (UV light)

    Lux meter & UV meter

    Thermometer

    *Use of Emulsifier depends upon the type of method chosen for PT

  • CLASSIFICATION OF PT:

    A. Based on type of examination techniquea) Visible color contrast method

    b) Fluorescent method

    B. Based on type of Penetrant removal processa) Solvent removable technique

    b) Water washable technique

    c) Post emulsifiable technique (Lipophilic)

    d) Post emulsifiable technique (Hydrophilic)

    LIQUID PENETRANT TESTING (PT)

  • LIQUID PENETRANT TESTING (PT)APPLICATION OF PT:

    Materials that can be examined with PT:

    PT can be applied on all non-porous materials. e.g. Metal, Plastic,Glass, Ceramics etc.

    TYPES OF DEFETCS CAN BE DETECTED WITH PT:

    Flaws that can be detected by PT:

    Only surface flaws can be detected.

    Cracks

    Porosity

    Laps

    Seams

    Lamination

    Cold shuts

  • LIQUID PENETRANT TESTING (PT)Good PT performance practice!!!

    Pre-cleaning: The surface to be examined along with adjacent areasof 25mm (1 inch.) must be free of oil, grease, lint, dirt, rust, spatter,welding flux, scale etc. If required, grinding or buffing needs to bedone other than solvent remover.

    Temperature: The temperature of surface to be examined &penetrant material should be within 5 to 52 C inclusive.

    Lighting requirement: The visible day light shall be 1000 luxminimum at the surface to be examined. If there is a insufficientlight condition to perform examination, than use 60W bulb from 9inch distance or 100W bulb from 12 inch distance as a thumb rule.

    In case, where fluorescent PT is applied, The visible ambient lightshall not be more than 20 lux in the darkened area. The UV lightused shall have 1000 W/cm2 intensity.

  • LIQUID PENETRANT TESTING (PT)

    ADVANTAGES: Highly sensitive to small surface discontinuities. Can be applied to all metallic and nonmetallic, magnetic and

    nonmagnetic, and conductive and nonconductive materials can beinspected.

    Large areas and large volumes of parts/materials can be inspectedrapidly and at low cost.

    Complex geometric parts are routinely inspected. Indications are produced directly on the surface of the part and

    constitute a visual representation of the flaw. Aerosol spray cans make penetrant materials very portable. Penetrant materials and associated equipment are relatively less

    costlier.

  • LIQUID PENETRANT TESTING (PT)

    LIMITATIONS: Only surface breaking defects can be detected. Only materials with a relatively nonporous surface can be

    inspected. Pre cleaning is critical since contaminants can mask defects. Metal smearing from machining, grinding, and grit or vapor blasting

    must be removed prior to PT. The inspector must have direct access to the surface being

    inspected. Surface finish and roughness can affect inspection sensitivity. Multiple process operations must be performed and controlled. Post cleaning of acceptable parts or materials is required. Chemical handling and proper disposal is required.

  • CODE ACCEPTANCE CRITERIA (ASME SECTION-I, A-270) Evaluation of indications

    Only indications with major dimensions greater than 1.5 mm shall beconsidered as relevant.

    Any doubtful indication shall be re-examined to confirm whether theyare relevant or not.

    Linear indication = l>3w Rounded indication = l3w

    Where,l = Length of indication andw = width of indication

    LIQUID PENETRANT TESTING (PT)

  • CODE ACCEPTANCE CRITERIA (ASME SECTION-I, A-270) (CONT.) Acceptance criteria

    All surfaces to be examined shall be free of: Any relevant linear indication Rounded indication more than 5mm dia. Four or more rounded indications in a line separated by 1.5mm or

    less distance (edge to edge)

    LIQUID PENETRANT TESTING (PT)

  • PT IN BOILER: HEADER

    Gas cutting/Machining of nozzle hole Fit up lug removal Circumferential welds Nozzle edge preparation Nozzle welding End plate welding Attachment welding Orifice welding Stub to tube welding All welding after PWHT

    LIQUID PENETRANT TESTING (PT)

  • PT IN BOILER: COIL

    Tube bending areas for Squeezing, Swaging (20%) [FOI] Tube to tube welding (25%) Attachment welding

    PANEL Tube to tube welding 10% on MPM welding

    LIQUID PENETRANT TESTING (PT)

  • INTRODUCTION TOMAGNETIC PARTICLE TESTING

  • OUTLINE Introduction & Working principle

    Basic operation procedure

    Equipments used in MT

    Direction of Magnetic field

    Application of MT

    Types of defect detected with MT

    Pros & Cons of MT

    Code Acceptance criteria

    MT in Boiler

    MAGNETIC PARTICLE TESTING (MT)

  • MAGNETIC PARTICLE TESTING (MT)INTRODUCTION:

    MT is relatively fast & easy to apply, part surface preparation isalso not essential parameter for this method.

    MT helps determining the flaws lying near surface also.

    MT uses magnetic fields & finely milled iron particles to detectflaws only in ferromagnetic test specimen.

    If iron particles are sprinkled on a cracked magnet, the ironparticles will be attracted to end of poles as well as at the edgesof the crack and form a cluster to make the flaw visible.

    This cluster of particles is much easier to see than the actualcrack and this is the basis for magnetic particle inspection.

  • MAGNETIC PARTICLE TESTING (MT)

    WORKING PRINCIPLE:

  • BASIC OPERATION PROCEDURE OF MT: Pre-cleaning: It is essential for the particles to have an unimpeded path for migration to

    both strong and weak leakage fields alike. The parts surface should be clean and drybefore inspection. Test surface shall be free of external particles like oil, grease, dirt, rustetc.

    Checking field adequacy: Pie shaped field indicator, flaw shims or tangential field probe(Gauss meter) shall be used to check proper set up of the equipment.

    Magnetizing the component: First step is to magnetize the component to be inspected.This can be accomplished by Prods, Yokes, Coil and conductive cables or Stationary MTmachine. MT can be done with various currents like AC, DC or HWDC.

    Application of Iron particles:

    After magnetizing the component, the iron particles are spread on the surface to beexamined. This can be accomplished either by Dry particle application or in Wetsuspended form.

    The particle will attracted and form a cluster at the flux leakage areas to make avisible indication.

    Interpretation/Evaluation:

    Evaluation of indication as per applicable code, or standard.

    Demagnetization:

    Demagnetize the specimen after completing the inspection, if required.

    MAGNETIC PARTICLE TESTING (MT)

  • BASIC OPERATION PROCEDURE OF MT: Pre-cleaning: It is essential for the particles to have an unimpeded path for migration to

    both strong and weak leakage fields alike. The parts surface should be clean and drybefore inspection. Test surface shall be free of external particles like oil, grease, dirt, rustetc.

    Checking field adequacy: Pie shaped field indicator, flaw shims or tangential field probe(Gauss meter) shall be used to check proper set up of the equipment.

    Magnetizing the component: First step is to magnetize the component to be inspected.This can be accomplished by Prods, Yokes, Coil and conductive cables or Stationary MTmachine. MT can be done with various currents like AC, DC or HWDC.

    Application of Iron particles:

    After magnetizing the component, the iron particles are spread on the surface to beexamined. This can be accomplished either by Dry particle application or in Wetsuspended form.

    The particle will attracted and form a cluster at the flux leakage areas to make avisible indication.

    Interpretation/Evaluation:

    Evaluation of indication as per applicable code, or standard.

    Demagnetization:

    Demagnetize the specimen after completing the inspection, if required.

    MAGNETIC PARTICLE TESTING (MT)

  • EQUIPMENTS USED IN MT:

    Prods

    Yoke

    Magnetizing coil & conductive cables

    Power source

    Stationary MT unit

    Black light

    Lux meter

    UV light meter

    Dry magnetic particles

    Wet magnetic particles

    Field indicator (Pie gage)

    Flaw shims

    Gauss meter (Tangential field probe)

    MAGNETIC PARTICLE TESTING (MT)

  • MAGNETIC PARTICLE TESTING (MT)Equipments used in MT:

    Portable Equipments

    Stationary Equipment

  • MAGNETIC PARTICLE TESTING (MT)Magnetizing current used in MT:

    FOR SKIN EFFECT

    & PARTICLE

    AGITATION

    TO DETECT

    DEFECTS LYING

    NEAR SURFACE

  • MAGNETIC PARTICLE TESTING (MT)Magnetic particles:

    Magnetic particles are mixture of rounded & slandered particleswith the size of 10 to 200 . It is also available in different colorsto enhance visibility, depending upon metallic background orthe applied contrast.

    Classification based on visibility.

    Visible (Non-Fluorescent) particles

    Fluorescent particles

    Classification based on carrier

    Dry particle

    Wet particle

  • MAGNETIC PARTICLE TESTING (MT)Magnetic particles:

    Wet Magnetic particles(Visible)

    Wet Magnetic particles(Fluorescent)

    Dry Magnetic particles

    Air as Carrier

    Bath concentration checking

    Liquid as Carrier

  • MAGNETIC PARTICLE TESTING (MT)Light Meters:

    Lux meter (White light) UV Light meter (Black light)

    Intensity of the light to be

    checked before start of

    examination, to verify

    adequacy of light.

  • MAGNETIC PARTICLE TESTING (MT)Field adequacy in MT:

    Pie shaped magnetic field indicator Tangential field probe

    Artificial flaw shims

  • MAGNETIC PARTICLE TESTING (MT)DIRECTION OF MAGNETIC FIELD & ORIENTATION OF DEFECTS:

    To properly inspect a part for defects, it is important to become familiarwith the different types of magnetic field.

    One of the primary requirements for detecting a defect in a ferromagneticmaterial is that the magnetic field induced in the part must intercept thedefect at a 45 to 90 angle. Flaws that are at 90 to the magnetic field willproduce the strongest indications because they disrupt more of themagnet flux.

    Therefore, for proper inspection of a component, it is important to be ableto establish a magnetic field in at least two directions.

  • MAGNETIC PARTICLE TESTING (MT)DIRECTION OF MAGNETIC FIELD:

    Two types of magnetic field

    A) Circular Magnetic field

    A circular magnetic field has magnetic lines of force that runcircumferentially around the perimeter of a part.

    Accomplished by passing the current through the solidbar/component.

    Also can be produced by passing current through centralconductor in hollow pipe.

    HEAD SHOT FOR CIRCULAR MAG. FIELD

  • MAGNETIC PARTICLE TESTING (MT)DIRECTION OF MAGNETIC FIELD:

    Two types of magnetic field (Cont.)

    B) Longitudinal Magnetic field

    Usually established by placing the part near the inside or a coilsannulus.

    This produces magnetic lines of force that are parallel to the long axisof the test part.

    LONGITUDINAL MAGNETIC FIELD (COIL SHOT)

    Portable

    coil

    Conductive

    cable

  • MAGNETIC PARTICLE TESTING (MT)DIRECTION OF MAGNETIC FIELD:

    Longitudinal Magnetic Particle Testing Equipment (YOKE)

    An electromagnetic yoke is a very common piece of equipment that isused to establish a magnetic field.

    It is basically made by wrapping an electrical coil around a piece of softferromagnetic steel.

    They can be powered with alternating current (AC) from a wall socket orby direct current (DC) from a battery pack.

    This type of magnet generates a very strong magnetic field in a local areawhere the poles of the magnet touch the part being inspected.

  • MAGNETIC PARTICLE TESTING (MT)DIRECTION OF MAGNETIC FIELD:

    Circular Magnetic Particle Testing Equipment (PROD)

    The current passing between the prods creates a circular magnetic fieldaround the prods that can be used in magnetic particle inspection. Prodsare typically made from copper and have an insulated handle.

    If proper contact is not maintained between the prods and the componentsurface, electrical arcing can occur and cause damage to the component.

  • MAGNETIC PARTICLE TESTING (MT)APPLICATION OF PT:

    Materials that can be examined with MT:

    MT can be applied on all ferromagnetic materials. e.g. Ferrite, Steel,Nickel, Cobalt alloys etc.

    TYPES OF DEFETCS CAN BE DETECTED WITH MT:

    Flaws that can be detected by MT:

    Surface & near surface flaws can be detected only in ferromagneticmaterial.

    Surface & near surface cracks

    Undercuts

    Lap

    Seam

    Lamination

  • ADVANTAGES Can detect both surface and near surface defects.

    Can inspect parts with irregular shapes easily.

    Pre-cleaning of components is not as critical as it is for some other inspectionmethods. Most contaminants within a flaw will not hinder flaw detectability.

    Fast method of inspection and indications are visible directly on the specimensurface.

    Considered low cost compared to many other NDT methods.

    Is a very portable inspection method especially when used with batterypowered equipment.

    MAGNETIC PARTICLE TESTING (MT)

  • LIMITATIONS Cannot inspect non-ferrous materials such as aluminum, magnesium or most

    stainless steels.

    Inspection of large parts may require use of equipment with special powerrequirements.

    Some parts may require removal of coating or plating to achieve desiredinspection sensitivity.

    Limited near surface discontinuity detection capabilities. Maximum depthsensitivity is approximately 0.6 (under ideal conditions).

    Post cleaning, and post demagnetization is often necessary.

    Alignment between magnetic flux and defect is important.

    MAGNETIC PARTICLE TESTING (MT)

  • CODE ACCEPTANCE CRITERIA (ASME SECTION-I, A-260) Evaluation of indications

    Only indications with major dimensions greater than 1.5 mm shall beconsidered as relevant. Any doubtful indication shall be re-examined to confirm whether

    they are relevant or not. Linear indication = l > 3w Rounded indication = l 3wWhere,

    l = Length of indication andw = width of indication

    MAGNETIC PARTICLE TESTING (MT)

  • CODE ACCEPTANCE CRITERIA (ASME SECTION-I, A-260) (CONT.)

    Acceptance criteria All surfaces to be examined shall be free of:

    Any relevant linear indication Rounded indication more than 5mm dia. Four or more rounded indications in a line separated by 1.5mm or

    less distance (edge to edge)

    MAGNETIC PARTICLE TESTING (MT)

  • MT IN BOILER: HEADER

    Gas cutting/Machining of nozzle hole Fit up lug removal Circumferential welds Nozzle edge preparation Nozzle welding End plate welding Attachment welding Orifice welding Stub to tube welding All welding after PWHT

    MAGNETIC PARTICLE TESTING (MT)

  • MT IN BOILER: COIL

    Attachment welding

    PANEL 10% on MPM welding. (Being implemented)

    MAGNETIC PARTICLE TESTING (MT)

  • INTRODUCTION TORADIOGRAPHY TESTING

  • OUTLINE Working principle

    Radiation sources

    Nature of X-rays & Gamma rays

    Gamma radiography

    X-ray radiography

    Film radiography

    Radiographic sensitivity

    Image Quality Indicators (IQI) or Penetrameters

    Examples of welding discontinuities in RT

    Radiographic acceptance standards

    Safety in radiation

    Application of RT

    Defects can be detected in RT

    Advantages & Limitations of RT

    RADIOGRAPHY TESTING (RT)

  • WORKING PRINCIPLE

    The part is placed between the radiation source and a piece of film. Thepart will absorb some of the radiation. Thicker and more dense area willabsorb more of the radiation.

    The film darkness (density) will vary with the amount of radiation reachingthe film through the test object.

    RADIOGRAPHY TESTING (RT)

  • RADIATION SOURCES

    Two of the most commonly used sources of radiation in industrialradiography are x-ray generators and gamma ray sources. Industrialradiography is often subdivided into X-ray Radiography orGamma Radiography, depending on the source of radiation used.

    RADIOGRAPHY TESTING (RT)

  • NATURE OF X-RAYS & GAMMA RAYS.

    They are form of Electromagnetic radiation

    They are extremely short in wavelength, about 1/10,000 of light, or even less.

    This feature makes rays able to penetrate in material that absorb or reflect ordinary light.

    The only difference in X-ray & Gamma-ray is that, X-rays are emitted from X-ray generator and Gamma rays are emitted from activated radioisotope.

    RADIOGRAPHY TESTING (RT)

  • NATURE OF X-RAYS & GAMMA RAYS (CONT.)

    RADIOGRAPHY TESTING (RT)

  • GAMMA RADIOGRAPHY

    Gamma rays are produced bya radioisotope.

    A radioisotope has anunstable nuclei that does nothave enough binding energyto hold the nucleus together.

    The spontaneous breakdownof an atomic nucleusresulting in the release ofenergy and matter is knownas radioactive decay.

    RADIOGRAPHY TESTING (RT)

  • GAMMA RADIOGRAPHY (CONT.)

    Most of the radioactivematerial used in industrialradiography is artificiallyproduced.

    This is done by subjectingstable material to a sourceof neutrons in a specialnuclear reactor.

    This process is calledactivation.

    RADIOGRAPHY TESTING (RT)

  • GAMMA RADIOGRAPHY (CONT.) Unlike X-rays, which are produced by a machine, gamma rays

    cannot be turned off. Radioisotopes used for gamma radiographyare encapsulated to prevent leakage of the material.

    The radioactive capsule is attached to a cable to form what isoften called a pigtail.

    The pigtail has a special connector at the other end that attaches toa drive cable.

    RADIOGRAPHY TESTING (RT)

  • GAMMA RADIOGRAPHY (CONT.) A device called a camera is used to store, transport and expose

    the pigtail containing the radioactive material. The camera containsshielding material which reduces the radiographers exposure toradiation during use.

    RADIOGRAPHY TESTING (RT)

  • GAMMA RADIOGRAPHY (CONT.) A hose-like device called a guide tube is connected to a threaded

    hole called an exit port in the camera. The radioactive material will leave and return to the camera

    through this opening when performing an exposure.

    RADIOGRAPHY TESTING (RT)

  • GAMMA RADIOGRAPHY (CONT.) A drive cable is connected to the

    other end of the camera. This cable,controlled by the radiographer, isused to force the radioactivematerial out into the guide tubewhere the gamma rays will passthrough the specimen and exposethe recording device.

    RADIOGRAPHY TESTING (RT)

  • X-RAY RADIOGRAPHY Unlike gamma rays, x-rays are produced by an X-ray generator

    system. These systems typically include an X-ray tube head, ahigh voltage generator, and a control console.

    RADIOGRAPHY TESTING (RT)

  • X-RAY RADIOGRAPHY (CONT.) X-rays are produced by establishing a very high voltage

    between two electrodes, called the anode and cathode. To prevent arcing, the anode and cathode are located inside a

    vacuum tube, which is protected by a metal housing.

    RADIOGRAPHY TESTING (RT)

  • X-RAY RADIOGRAPHY (CONT.) The cathode contains a small

    filament much the same as in a lightbulb.

    Current is passed through thefilament which heats it. The heatcauses electrons to be stripped off.

    The high voltage causes these freeelectrons to be pulled toward atarget material (usually made oftungsten) located in the anode.

    The electrons impact against thetarget. This impact causes an energyexchange which causes x-rays to becreated.

    High Electrical Potential

    Electrons

    -+

    X-ray Generator

    or Radioactive

    Source Creates

    Radiation

    Exposure Recording Device

    Radiation

    Penetrate

    the Sample

    RADIOGRAPHY TESTING (RT)

  • RADIATION INTERACTION WITH MATTER:

    Radiation absorption or scattering occurs depending upon energy of beam.

    Photoelectric absorptionCompton scattering

    RADIOGRAPHY TESTING (RT)

  • FILM RADIOGRAPHY One of the most widely used and

    oldest imaging mediums in industrialradiography is radiographic film.

    Film contains microscopic materialcalled silver bromide.

    Once exposed to radiation anddeveloped in a darkroom, silverbromide turns to black metallic silverwhich forms the image.

    RADIOGRAPHY TESTING (RT)

  • FILM RADIOGRAPHY (CONT.) Film must be protected from visible light. Light, just like x-rays and

    gamma rays, can expose film. Film is loaded in a light proofcassette in a darkroom.

    This cassette is then placed on the specimen opposite the source ofradiation. Film is often placed between screens to intensifyradiation.

    RADIOGRAPHY TESTING (RT)

  • FILM RADIOGRAPHY (CONT.) In order for the image to be viewed, the film must be developed

    in a darkroom. The process is very similar to photographic filmdevelopment.

    Film processing can either be performed manually in open tanksor in an automatic processor.

    RADIOGRAPHY TESTING (RT)

  • FILM RADIOGRAPHY (CONT.) Once developed, the film is typically referred to as a

    radiograph.

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING POROSITIES IN WELDING

  • RADIOGRAPHY IMAGING TECHNIQUES:Single wall single image (SWSI)

    RADIOGRAPHY TESTING (RT)

  • RADIOGRAPHY IMAGING TECHNIQUES:Double wall single image (DWSI)

    RADIOGRAPHY TESTING (RT)

  • RADIOGRAPHY IMAGING TECHNIQUES:Double wall double image (DWDI)

    RADIOGRAPHY TESTING (RT)

  • RADIOGRAPHIC SENSITIVITY It is the ability of a technique to determine smallest

    discontinuity. It is a combination of Radiographic contrast &Radiographic definition. Radiographic contrast is the density difference between two

    adjacent areas of the radiograph and is the net effect due to Film contrast & Subject contrast

    Radiographic definition refers to the sharpness of the radiographicimage. The causes of radiographic un-sharpness: Geometric un-sharpness (Ug) Movement un-sharpness (Um) Inherent or film un-sharpness (Ui) Scatter and screen un-sharpness (Us)

    RADIOGRAPHY TESTING (RT)

  • IMAGE QUALITY INDICATORS (IQI) OR PENETRAMETERS It is used to judge quality of a radiograph and is measured in

    terms of radiographic sensitivity. The penetrameter is available in various designs.

    e.g. Step type penetrameter Hole-step penetrameter Plate type penetrameter Wire type penetrameter Hole type penetrameter

    IQIs should be placed on the source side of radiation, if in case,it is not possible to put it at source side it should be placed filmside of radiation, in such case, letter F should be placed on thefilm.

    Wire type IQI should be placed across the weld. Hole type IQI should be placed parallel to the weld & 3mm

    apart from the weld edge.

    RADIOGRAPHY TESTING (RT)

  • RADIOGRAPHY TESTING (RT)

    HOLE TYPE PENETRAMETERS

    WIRE TYPE PENETRAMETERS

    FILM IDENTIFICATION LEAD

    LETTERS

  • LOCATION MARKER:

    Location markers are put to ensure total coverage of weld volume and for future traceability.

    Location marker shall always be put on job permanently and shall be visible on radiograph.

    RADIOGRAPHY TESTING (RT)

  • EXAMPLES OF WELDING DISCONTINUITIES IN RT

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING LACK OF PENETRATION IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING LACK OF FUSION IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING UNDER CUT IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING MIS-MATCH IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING CRACKS IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING TUNGSTEN INCLUSION IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING SLAG INCLUSION IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING CLUSTER POROSITY IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING SUCK BACK IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING BURN THROUGH IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING UNDERFILL IN WELDING

  • SOME EXAMPLES OF RADIOGRAPHIC FILMS

    RADIOGRAPHY TESTING (RT)

    RADIOGRAPH SHOWING EXCESS REINFORCEMENT IN WELDING

  • RADIOGRAPHY ACCEPTANCE STANDARD (ASME SECTION-I, PW-51) Crack, Lack of Fusion & Lack of Penetration are not acceptable. Any other elongated indication on the radiograph

    6mm for thickness (t) up to 19mm is acceptable. 1/3 t for thickness (t) 19mm to 57mm is acceptable. 19mm for thickness (t) over 57mm is acceptable.

    Total length of aligned indication greater than thk. of weld, in alength of radiograph, which is 12 times in length of thickness ofweld is not acceptable. If, distance between successive indicationexceeds 6L is acceptable. Where, L is the length of longestdiscontinuity in the group.

    Rounded indication acceptance standard as per A-250.

    RADIOGRAPHY TESTING (RT)

  • RADIOGRAPHY ACCEPTANCE STANDARD (ASME SECTION-I, PW-51)

    RADIOGRAPHY TESTING (RT)

    APPENDIX A-250 / TABLE A 250.3.2

  • RADIATION SAFETY Use of radiation sources in industrial radiography is heavily

    regulated by state and federal organizations due topotential public and personal risks.

    RADIOGRAPHY TESTING (RT)

  • RADIATION SAFETY There are many sources of radiation. In general, a person receives

    roughly 100 mrem/year from natural sources and roughly 100mrem/year from manmade sources.

    RADIOGRAPHY TESTING (RT)

  • RADIATION SAFETY X-rays and gamma rays are forms of ionizing radiation, which means

    that they have the ability to form ions in the material that ispenetrated. All living organisms are sensitive to the effects ofionizing radiation (radiation burns, x-ray food pasteurization, etc.)

    X-rays and gammarays have enoughenergy to liberateelectrons fromatoms and damagethe molecularstructure of cells.

    This can causeradiation burns orcancer.

    RADIOGRAPHY TESTING (RT)

  • RADIATION SAFETY Technicians who work with radiation must wear monitoring devices

    that keep track of their total absorption, and alert them when theyare in a high radiation area.

    Survey Meter Pocket Dosimeter Radiation Alarm Radiation Badge

    RADIOGRAPHY TESTING (RT)

  • RADIATION SAFETY There are three means of protection to help reduce exposure to

    radiation:

    RADIOGRAPHY TESTING (RT)

  • Advance Technology in RT: Real Time Radiography

    Real-time radiography (RTR), or real-time radioscopy, is a nondestructiveexamination (NDE) method whereby an image is produced electronicallyrather than on film so that very little lag time occurs between the itembeing exposed to radiation and the resulting image. In most instances,the electronic image that is viewed, results from the radiation passingthrough the object being inspected and interacting with a screen ofmaterial that fluoresces or gives off light when the interaction occurs.

    RADIOGRAPHY TESTING (RT)

  • Advance Technology in RT: Weld images from Real Time Radiography

    RADIOGRAPHY TESTING (RT)

    RTR image showing

    Voids in welding

    RTR image showing

    Crack in welding

  • APPLICATION OF RT Can be applied to all materials. E.g. Ferrous & Non-ferrous, metallic &

    non-metallic and all composites. Sensitive for all volumetric type of defects.DEFECTS CAN BE DETECTED BY RT: All type of cracks Lack of fusion (LoF) Lack of Penetration (LoP) Mismatch Inclusions (Tungsten, Slag & Oxides) Excess reinforcement Excess penetration (EP) Underfill Undercut Oxide Suck back Burn through

    RADIOGRAPHY TESTING (RT)

  • ADVANTAGES Permanent record & track of each and every welding is possible

    through film storage and joint identification. Technique is not limited by material type or density. Can inspect assembled components. Minimum surface preparation required. Sensitive to changes in thickness, corrosion, voids, cracks, and

    material density changes. Detects both surface and subsurface defects. Provides a permanent record of the inspection.

    RADIOGRAPHY TESTING (RT)

  • LIMITATIONS Many safety precautions for the use of high intensity radiation. Many hours of technician training prior to use. Access to both sides of sample required. Orientation of equipment and flaw can be critical. Determining flaw depth is impossible without additional angled

    exposures. Expensive initial equipment cost.

    RADIOGRAPHY TESTING (RT)

  • RT IN BOILER: HEADER

    Circumferential welds Orifice welds

    COIL Tube to tube welding

    PANEL Tube to tube welding

    RADIOGRAPHY TESTING (RT)

  • INTRODUCTION TOULTRASONIC TESTING

  • OUTLINE Working principle

    Types of sound waves & their propagation

    Type waves & particle motion

    Wavelength & frequency

    Attenuation of sound wave

    Acoustic impedance & its important

    Reflection & transmission

    Refraction

    UT equipments

    Data Presentation

    Calibration block

    DAC Curve

    UT of welding

    Advance technologies in UT

    Advantages & Limitations of UT

    Code acceptance criteria

    ULTRASONIC TESTING (UT)

  • WORKING PRINCIPLE: In Ultrasonic Testing the High frequency sound waves (Ultrasonic -

    Energy) are sent into the object. The sound waves travel throughthe material and the waves are reflected at interfaces.

    The probe picks up the reflected wave and an analysis of this signalis done.

    ULTRASONIC TESTING (UT)

  • ULTRASONIC TESTING (UT)

    SOUND WAVE PROPAGATION:

    At atomic level when vibration takes place in particle, It generatessound wave.

    Sound wave propagation depends on particle vibration direction.

  • WAVE TYPES IN

    SOLIDS

    PARTICLE

    VIBRATIONS

    LongitudinalParallel to wave

    direction

    Transverse (Shear)Perpendicular to wave

    direction

    Surface - Rayleigh Elliptical orbit -

    symmetrical mode

    ULTRASONIC TESTING (UT)

  • ULTRASONIC TESTING (UT)

    WAVELENGTH AND FREQUENCY:

  • ACOUSTIC IMPEDANCE Sound travels through materials under the influence of sound pressure.

    Because molecules or atoms of a solid are bound elastically to oneanother, the excess pressure results in a wave propagating through thesolid.

    The acoustic impedance (Z) of a material is defined as the product of itsdensity (p) and acoustic velocity (V). It is resistance of material to passageof the sound beam through material.

    Z = pV

    Acoustic impedance is important in

    the determination of acoustic transmission and reflection at the boundary of two materials having different acoustic impedances. Reflection is directly proportional to impedance ratio of two material.

    Air to any solid material impedance ratio is highest. So, UT is always sensitive for planer defects.

    assessing absorption of sound in a medium.

    ULTRASONIC TESTING (UT)

  • ULTRASONIC TESTING (UT)

    REFLECTION AND TRANSMISSION:

  • REFRACTION

    When an ultrasonic wave passes through an interface betweentwo materials at an oblique angle, and the materials havedifferent indices of refraction, both reflected and refractedwaves are produced.

    ULTRASONIC TESTING (UT)

  • ATTENUATION OF SOUND WAVE:

    Ultrasonic attenuation is the decay rate ofthe wave as it propagates through material.

    When sound travels through a medium, itsintensity diminishes with distance due toScattering and Absorption.

    Scattering is the reflection of the sound indirections other than its original direction ofpropagation.

    Absorption is the conversion of the sound energyto other forms of energy.

    The combined effect of scattering and absorptionis called attenuation.

    ULTRASONIC TESTING (UT)

  • BASIC SET UP OF UT:

    Transducer (1)

    Cable (2)

    Ultrasonic Flaw Detector (3)

    Couplant (4)

    3 2

    1

    4

    ULTRASONIC TESTING (UT)

  • TRANSDUCERS (PROBE)

    Principle : Converts Electrical Energy into Mechanical Energy andvice-versa(Pie)

    ULTRASONIC TESTING (UT)

  • PIEZOELECTRIC MATERIAL

    Case-1 - Mechanical Energy converts into Electrical energy

    Case-2 - Electrical Energy converts into Mechanical Energy

    ULTRASONIC TESTING (UT)

  • PROBE (TRANSDUCER) TYPES:

    Contact Transducers

    Used for direct contact inspections.

    Coupling materials of water, grease, oils, orcommercial materials are used to remove theair gap between the transducer and thecomponent being inspected.

    Immersion Transducers

    Do not contact the component.

    Specially designed to operate in a liquidenvironment.

    Transducers are available with a planer,cylindrically focused or sphericallyfocused lens.

    ULTRASONIC TESTING (UT)

  • PROBE (TRANSDUCER) TYPES (CONT.):0 (Normal) beam TransducersSingle Crystal Probe:

    Single crystal element is used both for transmitting andreceiving.

    Dual Crystal Probe:

    Contain two independently operated elements in a singlehousing.

    One of the elements transmits and the other receives theultrasonic signal.

    Applicable for the inspection of course grained material.

    Well suited for making measurements in applications wherereflectors are very near the transducer.

    Angle beam probe

    Used to introduce a refracted shear wave into the test material.

    Available in a variety of fixed angles or in adjustable versionswhere the user determines the angles of incidence andrefraction.

    Probe angles 45, 60 and 70 are being used widely.

    ULTRASONIC TESTING (UT)

  • Single Point Dual Point Multi Point

    WAVE INTERFERENCE The sound that emanates from an ultrasonic transducer does not originate

    from a single point, but instead originates from many points along thesurface of the piezoelectric element

    This results in a sound field with many waves interacting or interferingwith each other.

    When waves interact, they superimpose on each other, and the amplitudeof the sound pressure or particle displacement at any point of interactionis the sum of the amplitudes of the two individual waves.

    ULTRASONIC TESTING (UT)

  • ULTRASONIC TESTING (UT)

    NEAR FIELD AND FAR FIELD:

    Near Field: Wave interference leads to extensive fluctuations in thesound intensity near the source and is known as the near field.

    Far Field: The area just beyond the near field is where the soundwave is well behaved and at its maximum strength. Therefore,optimal detection results will be obtained when flaws occur in thisarea.

  • DEAD ZONE:

    It is the interval following the surface of a test object to the nearestinspectable depth. Any interval following a reflected signal where nodirect echoes from discontinuities cannot be detected, due tocharacteristics of the equipment.

    ULTRASONIC TESTING (UT)

  • PULSER /RECEIVER OR ULTRASONIC FLAW DETECTOR (UFD):

    The pulser section of the instrument generates short, large amplitudeelectric pulses of controlled energy, which are converted into shortultrasonic pulses when applied to an ultrasonic transducer.

    In the receiver section the voltage signals produced by the transducer,which represent the received ultrasonic pulses, are amplified. Theamplified radio frequency (RF) signal is available as an output fordisplay or capture for signal processing.

    ULTRASONIC TESTING (UT)

    Analog

    Digital

  • COAXIAL CABLEA: outer plastic sheathB: woven copper shieldC: inner dielectric insulatorD: copper-plated core

    ULTRASONIC TESTING (UT)

  • COUPLANT:Couplant is used to nullify air gap between probe and specimen surface.

    Couplant medias areWaterOilGreaseCellulose paste

    ULTRASONIC TESTING (UT)

  • DATA REPRESENTATION:

    A-Scan

    B-Scan

    C-Scan

    ULTRASONIC TESTING (UT)

  • A-SCAN The A-scan presentation displays the amount of received ultrasonic

    energy as a function of time. The relative amount of received energyis plotted along the vertical axis and the elapsed time (which may berelated to the sound energy travel time within the material) isdisplayed along the horizontal axis.

    ULTRASONIC TESTING (UT)

  • A-SCAN UT VISUALIZATION (NORMAL PROBE)

    ULTRASONIC TESTING (UT)

  • ULTRASONIC TESTING (UT)A-SCAN UT VISUALIZATION (ANGLE PROBE)

  • B-SCAN The B-scan presentations is a profile (cross-sectional) view of the test

    specimen. In the B-scan, the time-of-flight (travel time) of the sound energy is displayed along the vertical axis and the linear position of the transducer is displayed along the horizontal axis.

    In the B-scan, the depth of the reflector and its approximate linear dimensions in the scan direction can be determined.

    ULTRASONIC TESTING (UT)

  • C-SCAN The C-scan presentation provides a plan-type

    view of the location and size of test specimenfeatures. The plane of the image is parallel tothe scan pattern of the transducer.

    C-scan presentations are produced with anautomated data acquisition system, such as acomputer controlled immersion scanningsystem.

    ULTRASONIC TESTING (UT)

  • CALIBRATION Calibration refers to the act of evaluating and adjusting the precision

    and accuracy of measurement equipment.

    REFERENCE STANDARDS : To establish a general level of consistency in measurements and to help

    interpret and quantify the information contained in the received signal. To validate that the equipment and the setup provide similar results from

    one day to the next and that similar results are produced by differentsystems.

    Help the inspector to estimate the size of flaws. Signal strength depends on both the size of the flaw and the distance

    between the flaw and the transducer. The inspector can use a reference standard with an artificially induced flaw

    of known size and at approximately the same distance away for thetransducer to produce a signal

    By comparing the signal from the reference standard to that received fromthe actual flaw, the inspector can estimate the flaw size.

    ULTRASONIC TESTING (UT)

  • Calibration Blocks

    ULTRASONIC TESTING (UT)

  • DISTANCE AMPLITUDE CORRECTION (DAC):

    Acoustic signals from the same reflecting surface will havedifferent amplitudes at different distances from thetransducer.

    Acoustic signals from the same reflecting surface will havedifferent amplitudes at different distances from thetransducer.

    ULTRASONIC TESTING (UT)

  • UFD

    ULTRASONIC TESTING (UT)

  • UT OF WELDED JOINTS:

    ULTRASONIC TESTING (UT)

  • ULTRASONIC TESTING (UT)

    SCANNING PATTERN AND DIRECTION:

    Maximum reflection can be achieved when flaw is lyingperpendicular to beam direction.

    Probe angle selection should be such that beam shall hitperpendicular to the side wall of weld groove.

    The best practice is to scan from two different direction andwith two different angle beam probes.

    Mainly three types of scanning patterns are used to getreflection from defects lying at any orientation. Longitudinal scanning Transverse scanning Orbital scanning

  • ADVANCED UT (PHASED ARRAY)

    Phased arrays use an array of elements, all individuallywired, pulsed and time-shifted.

    These elements can be a linear array, a 2D matrix array,a circular array or some more complex form.

    ULTRASONIC TESTING (UT)

  • WORKING PRINCIPLE: All arrays are operated individually, It will give us various types of wave

    configuration.

    Ultrasonic phased arrays use a multiple element probe whereby theoutput pulse from each element is time delayed in such a way so asproduce constructive interference at a specific angle and a specific depth.These time delays can be incremented over a range of angles to sweep thebeam over the desired angular range.

    Focused Normal beam Focused Shear wave

    ULTRASONIC TESTING (UT)

  • ULTRASONIC TESTING (UT)

    DATA PRESENTATION:

  • TIME OF FLIGHT DEFRACTION: The TOFD technique is based on diffraction of ultrasonic waves on tips of

    discontinuities, instead of geometrical reflection on the interface of thediscontinuities

    When ultrasound is incident at linear discontinuity such as crack, diffraction takesplace at its extremities. Usually TOFD technique uses a pair of probes.

    One Acts as an emitter of ultrasound, the other as a receiver. The longitudinalsound beam can encounter obstacles on its path, which cause reflected anddiffracted signals. When the probes are moved parallel along the weld, theresultant waveforms are digitized, stored on hard disk and displayed on the screen.

    Using this advanced technique gas and binding defects, slag inclusions and crackscan be detected independent of defect orientation with very accurate sizing of thedefects (0.5-1.0 mm).

    ULTRASONIC TESTING (UT)

  • Transmitter Receiver

    Lateral wave

    Upper tip

    Lower tip

    Back-wall reflection

    ULTRASONIC TESTING (UT)

    TOFD SIGNALS:

  • The crack blocks the Lateral Wave

    And the lower tip appears on the A-scan

    21

    1

    2

    ULTRASONIC TESTING (UT)DATA PRESENTATION:

  • ULTRASONIC TESTING (UT)APPLICATION OF UT: Can be applied to all materials. E.g. Ferrous & Non-ferrous, metallic

    & non-metallic and all composites. Practically there is no anythickness limitation to perform UT.

    DEFECTS CAN BE DETECTED BY UT: All type of cracks Lack of fusion (LoF) Lack of Penetration (LoP) Inclusions (Tungsten, Slag & Oxides) Excess penetration (EP) Undercut

  • ADVANTAGES OF UT: It is sensitive to both surface and subsurface discontinuities. The depth of penetration for flaw detection or measurement is

    superior to other NDT methods. Only single-sided access is needed when the pulse-echo

    technique is used. It is highly accurate in determining reflector position and

    estimating size and shape. Minimal part preparation is required. Electronic equipment provides instantaneous results. Detailed images can be produced with automated systems. It has other uses, such as thickness measurement, in addition to

    flaw detection.

    ULTRASONIC TESTING (UT)

  • LIMITATIONS OF UT: Surface must be accessible to transmit ultrasound. Skill and training is more extensive than with some other methods. It normally requires a coupling medium to promote the transfer of

    sound energy into the test specimen. Materials that are rough, irregular in shape, very small,

    exceptionally thin or not homogeneous are difficult to inspect. Cast iron and other coarse grained materials are difficult to inspect

    due to low sound transmission and high signal noise. Linear defects oriented parallel to the sound beam may go

    undetected. Reference standards are required for both equipment calibration

    and the characterization of flaws.

    ULTRASONIC TESTING (UT)

  • ULTRASONIC TESTING (UT)ACCEPTANCE CRITERIA AS PER ASME SECTION-1 PW -52: Technique and standards for ultrasonic examination are given in ASME

    Section V, Article 4 & 5. Imperfections that cause an indication greater than 20% of the reference

    level shall be investigated to the extent that the ultrasonic examinationpersonnel can determine their shape, identity, and location, and evaluatethem in terms of PW-52.3.1 and PW-52.3.2.

    Cracks, lack of fusion, or incomplete penetration are not acceptableregardless of length.

    Other imperfections are unacceptable if the indication exceeds thereference level and their length exceeds the following: 6 mm for t up to 19 mm 13t for t from 19 mm to 57 mm 19 mm for t over 57 mm

    Notes :- where t is the thickness of the weld being examined. If the weldjoins two members having different thicknesses at the weld, t is the thinnerof these two thickness.

  • UT IN BOILER: Header

    T-piece branch connection Manifold support bolts Depth confirmation (If repair found in Cir. Seams) Above 48mm thk

    ULTRASONIC TESTING (UT)

  • MATERIAL

    FLAW TYPE

    Surface

    flaw

    Sub-surface

    flaw

    Internal

    flaw

    Lack of

    fusion

    Inclusions

    e.g. slag, T.I.

    Material

    quality

    Lamination &

    thickness

    measurement

    Ferrous forgings M.T.M.T.

    U.T.

    R.T.

    U.T.---

    R.T.

    U.T.--- U.T.

    Ferrous raw

    material

    M.T. M.T.

    U.T.U.T. ---

    M.T.

    U.T.--- U.T.

    Ferrous tube &

    pipe

    M.T.

    E.T.

    M.T.

    U.T.U.T. U.T.

    M.T.

    U.T.--- U.T.

    Ferrous weldsM.T.

    U.T.U.T.

    R.T.

    U.T.

    R.T.

    U.T.

    R.T.

    U.T.--- U.T.

    Steel castings M.T.M.T.

    U.T.

    R.T.

    U.T.---

    R.T.

    U.T.--- U.T.

    Iron castings M.T.U.T.

    E.T.U.T. ---

    R.T.

    U.T.U.T. U.T.

    Non-Fe materialsP.T.

    E.T.---

    R.T.

    U.T.U.T.

    P.T.

    U.T.--- U.T.

    Fe finished

    materialsM.T.

    U.T.

    E.T.

    R.T.

    U.T.U.T.

    M.T.

    U.T.--- U.T.

    Non-Fe finished

    materials

    P.T.

    E.T.

    U.T.

    E.T.

    R.T.

    U.T.---

    U.T.

    E.T.--- U.T.

    APPLICATION OF N.D.E.

  • APPLICATION OF N.D.E.N.D.E. IN BOILER INDUSTRY: Boiler testing for welding defects both during manufacturing and in

    service. Boiler piping thickness measurement and turbine component testing.

  • THANK YOU