Ameristar · are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor...
Transcript of Ameristar · are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor...
Product Specifications
OUTDOOR UNIT
POWER CONNS. — V/PH/HZ
MIN. BRCH. CIR. AMPACITY
BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR
NO. USED - NO. SPEEDS
VOLTS/PH/HZ
R.L. AMPS - L.R. AMPS
FACTORY INSTALLED
START COMPONENTS INSULATION/SOUND BLANKETCOMPRESSOR HEAT
OUTDOOR FAN
DIA. (IN.) - NO. USED
TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G.
NO. MOTORS - HP
MOTOR SPEED R.P.M.
VOLTS/PH/HZ
F.L. AMPS
OUTDOOR COIL — TYPE
ROWS - F.P.I.
FACE AREA (SQ. FT.)
TUBE SIZE (IN.)
REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT)
FACTORY SUPPLIED
LINE SIZE - IN. O.D. GAS
LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION
SUBCOOLING
DIMENSIONS
CRATED (IN.)
WEIGHT
SHIPPING (LBS.)
NET (LBS.)
M4HP4018C1000AA
TAG: _________________________________
1.5 Ton Split System
M4HP4018C1000AA
SUBMITTAL
M4HP4018C1000AA208/230/1/60
10.415
SCROLL1 - 1
208/230/1/607.7-48.0
PROPELLER17-3/4 - 1
DIRECT - 118001 - 1/81075
208/230/1/600.7
PLATE FIN2 - 2110.03/16
ORIFICE
5 LBS. - 5 OZ.YES
3/43/8
8º FH X W X D
143137
NONO
AIR DISCHARGE: ALLOW 60” MINIMUM CLEARANCE.
CONTROL WIRING7/8” (22.2mm)
KNOCKOUT1-11/32”(34.5mm)
LIQUID LINECONNECTION
SERVICEFITTINGSERVICE
FITTING
POWER WIRINGSEE DETAIL A
DETAIL A
HOLE1-3/32”(27.8mm)
SERVICE ACCESSALLOW 24” CLEARANCE
AIR INLETSLOUVERED PANELSALLOW 12”MINIMUMCLEARANCE
NOTE: GRILL APPEARANCE MAY VARY.
W
VAPOR LINE CONNECTION
M4HP4018C1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 600 (23-5/8) 3/8 3/4
Ameristar
NOTE: All dimensions are in mm/inches.
600 (23-5/8)
Heat Pump - 1 Phase
YES
A
26-1/4X24-7/10-24-7/10
Literature Order Number SS-PRC007-EN
File Number —
Supersedes SS-PRC007-EN 2/02
Stocking Location PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats
When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4HP40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor, high pressure switch and low pressure switch. The factory installed crankcase heat can protect compress when it stands by.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLED
START COMPONENTS INSULATION/SOUND BLANKETCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE
ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4HP4024C1000AA
TAG: _________________________________
2.0 Ton Split System
M4HP4024C1000AA
SUBMITTAL
M4HP4024C1000AA208/230/1/60
13.420
SCROLL1 - 1
208/230/1/6010.1-52
PROPELLER18-7/8 - 1
DIRECT - 118001 - 1/81075
208/230/1/600.7
PLATE FIN2 - 2110.03/16
ORIFICE
5 LBS. - 2 OZ.YES3/43/8
8º FH X W X D
26-1/4x24-7/10x24-7/10
146139
NONO
AIR DISCHARGE: ALLOW 60” MINIMUM CLEARANCE.
CONTROL WIRING7/8” (22.2mm)
KNOCKOUT1-11/32”(34.5mm)
LIQUID LINECONNECTION
SERVICEFITTINGSERVICE
FITTING
POWER WIRINGSEE DETAIL A
DETAIL A
HOLE1-3/32”(27.8mm)
SERVICE ACCESSALLOW 24” CLEARANCE
AIR INLETSLOUVERED PANELSALLOW 12”MINIMUMCLEARANCE
NOTE: GRILL APPEARANCE MAY VARY.
W
VAPOR LINE CONNECTION
M4HP4024C1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 600 (23-5/8) 3/8 3/4
Ameristar
NOTE: All dimensions are in mm/inches.
600 (23-5/8)
Heat Pump - 1 Phase
YES
A
Literature Order Number SS-PRC007-EN
File Number —
Supersedes SS-PRC007-EN 2/02
Stocking Location PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats
When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4HP40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor, high pressure switch and low pressure switch. The factory installed crankcase heat can protect compress when it stands by.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLED
START COMPONENTS INSULATION/SOUND BLANKETCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE
ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4HP4030B1000AA
TAG: _________________________________
2.5 Ton Split System
M4HP4030B1000AA
SUBMITTAL
M4HP4030B1000AA208/230/1/60
16.525
SCROLL1 - 1
208/230/1/6012.4-63.0
PROPELLER23 - 1
DIRECT - 125001 - 1/6
825208/230/1/60
1.0PLATE FIN
2 - 2112.83/16
ORIFICE
6 LBS. - 7 OZ.YES3/43/8
8º FH X W X D26/1-4x29 x29
161152
NONO
AIR DISCHARGE: ALLOW 60” MINIMUM CLEARANCE.
CONTROL WIRING7/8” (22.2mm)
KNOCKOUT1-11/32”(34.5mm)
LIQUID LINECONNECTION
SERVICEFITTINGSERVICE
FITTING
POWER WIRINGSEE DETAIL A
DETAIL A
HOLE1-3/32”(27.8mm)
SERVICE ACCESSALLOW 24” CLEARANCE
AIR INLETSLOUVERED PANELSALLOW 12”MINIMUMCLEARANCE
NOTE: GRILL APPEARANCE MAY VARY.
W
VAPOR LINE CONNECTION
M4HP4030B1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 710 (28) 3/8 3/4
Ameristar
NOTE: All dimensions are in mm/inches.
710 (28)
Heat Pump - 1 Phase
YES
A
Literature Order Number SS-PRC007-EN
File Number —
Supersedes SS-PRC007-EN 2/02
Stocking Location PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats
When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4HP40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor, high pressure switch and low pressure switch. The factory installed crankcase heat can protect compress when it stands by.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLED
START COMPONENTS INSULATION/SOUND BLANKETCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE
ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4HP4036B1000AA
TAG: _________________________________
3.0 Ton Split SystemHeat Pump - 1 Phase M4HP4036B1000AA
SUBMITTAL
M4HP4036B1000AA208/230/1/60
19.430
SCROLL1 - 1
208/230/1/6014.7-75.0
PROPELLER23-5/8 - 1
DIRECT - 127001 - 1/6825
208/230/1/601.0
PLATE FIN2 - 2113.63/16
ORIFICE
6 LBS. - 11 OZ.YES3/43/8
8º FH X W X D
26-1/4 x 30-1/5 x 30-1/5
177168
NONO
AIR DISCHARGE: ALLOW 60” MINIMUM CLEARANCE.
CONTROL WIRING7/8” (22.2mm)
KNOCKOUT1-11/32”(34.5mm)
LIQUID LINECONNECTION
SERVICEFITTINGSERVICE
FITTING
POWER WIRINGSEE DETAIL A
DETAIL A
HOLE1-3/32”(27.8mm)
SERVICE ACCESSALLOW 24” CLEARANCE
AIR INLETSLOUVERED PANELSALLOW 12”MINIMUMCLEARANCE
NOTE: GRILL APPEARANCE MAY VARY.
W
VAPOR LINE CONNECTION
M4HP4036B1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
633 (24-15/16) 740 (29-1/8) 3/8 3/4
Ameristar
NOTE: All dimensions are in mm/inches.
740 (29-1/8)
YES
A
Literature Order Number SS-PRC007-EN
File Number —
Supersedes SS-PRC007-EN 2/02
Stocking Location PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats
When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4HP40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor, high pressure switch and low pressure switch. The factory installed crankcase heat can protect compress when it stands by.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLED
START COMPONENTS INSULATION/SOUND BLANKETCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE
ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4HP4042B1000AA
TAG: _________________________________
3.5 Ton Split System
M4HP4042B1000AA
SUBMITTAL
M4HP4042B1000AA208/230/1/60
21.635
SCROLL1 - 1
208/230/1/6015.9-112.3
PROPELLER23 - 1
DIRECT - 137001 - 1/31075
208/230/1/601.7
PLATE FIN2 - 2117.43/16
ORIFICE
8 LBS. - 3 OZ.YES3/43/8
8º FH X W X D34-1/2x29x29
212201
NONO
AIR DISCHARGE: ALLOW 60” MINIMUM CLEARANCE.
CONTROL WIRING7/8” (22.2mm)
KNOCKOUT1-11/32”(34.5mm)
LIQUID LINECONNECTION
SERVICEFITTINGSERVICE
FITTING
POWER WIRINGSEE DETAIL A
DETAIL A
HOLE1-3/32”(27.8mm)
SERVICE ACCESSALLOW 24” CLEARANCE
AIR INLETSLOUVERED PANELSALLOW 12”MINIMUMCLEARANCE
NOTE: GRILL APPEARANCE MAY VARY.
W
VAPOR LINE CONNECTION
M4HP4042B1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
843 (33-3/16) 710 (28) 3/8 3/4
Ameristar
NOTE: All dimensions are in mm/inches.
710 (28)
Heat Pump - 1 Phase
YES
A
Literature Order Number SS-PRC007-EN
File Number —
Supersedes SS-PRC007-EN 2/02
Stocking Location PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats
When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4HP40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor, high pressure switch and low pressure switch. The factory installed crankcase heat can protect compress when it stands by.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLED
START COMPONENTS INSULATION/SOUND BLANKETCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE
ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4HP4048B1000AA
TAG: _________________________________
4.0 Ton Split System Heat Pump - 1 Phase M4HP4048B1000AA
SUBMITTAL
M4HP4048B1000AA208/230/1/60
24.640
SCROLL1 - 1
208/230/1/6018.3-108.0
PROPELLER23 - 1
DIRECT - 137001 - 1/31075
208/230/1/601.7
PLATE FIN2 - 2117.43/16
ORIFICE
8 LBS. - 1 OZ.YES7/83/8
8º FH X W X D34-1/2x29x29
214203
NONO
AIR DISCHARGE: ALLOW 60” MINIMUM CLEARANCE.
CONTROL WIRING7/8” (22.2mm)
KNOCKOUT1-11/32”(34.5mm)
LIQUID LINECONNECTION
SERVICEFITTINGSERVICE
FITTING
POWER WIRINGSEE DETAIL A
DETAIL A
HOLE1-3/32”(27.8mm)
SERVICE ACCESSALLOW 24” CLEARANCE
AIR INLETSLOUVERED PANELSALLOW 12”MINIMUMCLEARANCE
NOTE: GRILL APPEARANCE MAY VARY.
W
VAPOR LINE CONNECTION
M4HP4048B1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
843 (33-3/16) 710 (28) 3/8 7/8
Ameristar
NOTE: All dimensions are in mm/inches.
710 (28)
YES
A
Literature Order Number SS-PRC007-EN
File Number —
Supersedes SS-PRC007-EN 2/02
Stocking Location PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats
When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4HP40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor, high pressure switch and low pressure switch. The factory installed crankcase heat can protect compress when it stands by.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
Product Specifications OUTDOOR UNIT
POWER CONNS. — V/PH/HZ MIN. BRCH. CIR. AMPACITY BR. CIR. PROT. RTG. - MAX. (AMPS)
COMPRESSOR NO. USED - NO. SPEEDS VOLTS/PH/HZ R.L. AMPS - L.R. AMPS FACTORY INSTALLED
START COMPONENTS INSULATION/SOUND BLANKETCOMPRESSOR HEAT
OUTDOOR FAN DIA. (IN.) - NO. USED TYPE DRIVE - NO. SPEEDS CFM @ 0.0 IN. W.G. NO. MOTORS - HP MOTOR SPEED R.P.M. VOLTS/PH/HZ F.L. AMPS
OUTDOOR COIL — TYPE
ROWS - F.P.I. FACE AREA (SQ. FT.) TUBE SIZE (IN.) REFRIGERANT CONTROL
REFRIGERANT
LBS. — R-410 (O.D. UNIT) FACTORY SUPPLIED LINE SIZE - IN. O.D. GAS LINE SIZE - IN. O.D. LIQ.
CHARGING SPECIFICATION SUBCOOLING
DIMENSIONS CRATED (IN.) WEIGHT SHIPPING (LBS.) NET (LBS.)
M4HP4060B1000AA
TAG: _________________________________
5.0 Ton Split System Heat Pump - 1 Phase M4HP4060B1000AA
SUBMITTAL
M4HP4060B1000AA208/230/1/60
29.650
SCROLL1 - 1
208/230/1/6022.3-127.9
PROPELLER23-5/8 - 1DIRECT - 1
42501 - 1/31075
208/230/1/601.7
PLATE FIN3 - 1918.49/32
ORIFICE
11 LBS. - 6 OZ.YES7/83/8
8º FH X W X D
34-1/2x30-1/5x30-1/5
238227
NONO
AIR DISCHARGE: ALLOW 60” MINIMUM CLEARANCE.
CONTROL WIRING7/8” (22.2mm)
KNOCKOUT1-11/32”(34.5mm)
LIQUID LINECONNECTION
SERVICEFITTINGSERVICE
FITTING
POWER WIRINGSEE DETAIL A
DETAIL A
HOLE1-3/32”(27.8mm)
SERVICE ACCESSALLOW 24” CLEARANCE
AIR INLETSLOUVERED PANELSALLOW 12”MINIMUMCLEARANCE
NOTE: GRILL APPEARANCE MAY VARY.
W
VAPOR LINE CONNECTION
M4HP4060B1000AA
Model H W L LIQUID VALVE SIZE GAS VALVE SIZE
843 (33-3/16) 740 (29-1/8) 3/8 7/8
Ameristar
NOTE: All dimensions are in mm/inches.
740 (29-1/8)
YES
A
Literature Order Number SS-PRC007-EN
File Number —
Supersedes SS-PRC007-EN 2/02
Stocking Location PI Louisville & Webb/Mason Houston
Ameristar has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
MechanicalSpecification Options
General
Casing
Refrigerant Controls
Scroll Compressor
Condenser Coil
Optional accessoriesThermostats When choosing a thermostat,choose a non-programmable electric thermostat series. Please refer to the thermostat electrical manual wiring schematic.
Liquid line drier —
Ameristar
The M4HP40 is fully charged from the factory. This unit is designed to operateat outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is certified to ETL. Exterior is designed for outdoor application.
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather-resistant powder paint on all grilles, panels, pre-paint on all other panels. And had 500-hours salt spray tested.
Refrigeration system controls include condenserfan, compressor contactor, high pressure switch and low pressure switch. The factory installed crankcase heat can protect compress when it stands by.
Features include low vibration and noise.
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.
It is used to filter out impurities and water in the system, ensures system clean and dry.
—
01/15/18