All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC...

10
All solutions Waterchillers Heat pumps NA 04.07 E

Transcript of All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC...

Page 1: All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC CIATESA plant Acoustic chamber CIAT laboratory NA0407_200.qxd 18/02/2009 10:57 Page

All solutions

W a t e r c h i l l e r sH e a t p u m p s

NA

04.

07 E

NA0407_205.qxd 18/02/2009 11:49 Page 2

Page 2: All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC CIATESA plant Acoustic chamber CIAT laboratory NA0407_200.qxd 18/02/2009 10:57 Page

The CIAT GroupFounded in 1934, Ciat has grown constantly inbusiness activities such as air conditioning,

refrigeration and air handling to reach its currentposition as one of the leading firms in Europe.The group's world-widepresence on 9 industrialproduction sites with aninternational sales networkconsisting of subsidiariesand approved distributors in

over 70 countries is a signof our strategicdetermination to remainas close to our markets aspossible.The group's expertiseserves as a reference inall its areas of activity.CIAT offers advice, after-sales service and suitabletraining for professionals to optimise their servicesfor the Group's products.The company's international vocation is now areality, with over half of our sales generated outside France.

The R&D,m a r k e t i n g ,logistic ands a l e sdepar tmen tsbased in Culoz,France, in theheart of thel a r g e s tindustrial site,

work in close cooperation with the Group's companies.The water chiller and heat pump ranges aredesigned and manufactured in recent state-of-the-art plants, benefiting from all theGroup's industrial resources. Almost 70,000 m2and 1000 employees are entirely dedicated to thisactivity, representing theheart of the company'sbusiness.

Culoz – France, CIAT industrial site

Montilla Cordoba SpainCIATESA plant

Test platformCIAT laboratory

Folding PLCCIATESA plant

Acoustic chamberCIAT laboratory

NA0407_200.qxd 18/02/2009 10:57 Page 1

Page 3: All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC CIATESA plant Acoustic chamber CIAT laboratory NA0407_200.qxd 18/02/2009 10:57 Page

With over 50 ranges representing over 1000 different

units, the Ciat water chiller and heat pump range is one

of the leading ranges on international

markets.

With low, medium or high capacities,

professionals can avail of all cooling and

heating technologies: air condensation,

water condensation, chilled or hot water

production, air diffusion.

This exceptional range is completed with

smart control systems, "plug and cool"

systems or specific versions such as

dehumidifiers.

Ciat provides those involved in

specification and installation with solutions

for all the requirements expressed in the

residential, tertiary or industrial sector.

These extensive solutions guarantee that

your Ciat correspondents will be completely objective in

the choice of the equipment required for technical,

geographic or economic reasons or to adapt to

pre-existing situations.

The Ciat water chillers and heat pumps, manufactured in

ISO 9001 certified modern plants have been awarded the

Eurovent label, guaranteeing the technical performances

specified.

Water chillersand heat pumps

A unique Europeanrange

Cooling only version

Heat pump version

Hydraulic module version

Condenser-free version

Heat recovery unit

Equipment andversions available:

Scroll compressor

Screw compressor

High Temperature

NA0407_205.qxd 18/02/2009 11:52 Page 3

Page 4: All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC CIATESA plant Acoustic chamber CIAT laboratory NA0407_200.qxd 18/02/2009 10:57 Page

Water condensation chilled waterproduction units

EUROPA 2288 models 30 to 750 kW

AIRIAL54 models 10 to 120 kW

DYNACIAT LGILGLGN15 models 35 to 350 kW

D R Y C O O L E R S

Nouveau LG

A I R C O O L E D C O N D E N S E R S

VEXTRAOver 220 models up to 1350 kW

VEMAX

HYDROCIAT LWLWN19 models 265 to 1115 kW

AGEO 7 models 7 to 36 kW

AGEOCALEO

4 models 16 to 25 kW

NA0407_205.qxd 18/02/2009 11:56 Page 4

Page 5: All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC CIATESA plant Acoustic chamber CIAT laboratory NA0407_200.qxd 18/02/2009 10:57 Page

P R O P E L L E Rair condensation chilled

AQUACIAT 2LD LDH - LDC20 models 20 to 300 kW

AQUALIS 2

6 models 6 to 19 kW

POWERCIATLXLXH - LXC19 models 230 to 1100 kW

AQUALIS CALEO

3 models 13 to 20 kW

AQUACIAT 2ILDILDH - ILDC

AQUACIAT GRAND INVERTERIVDC2 models35 to 50 kW

AQUACIAT CALEO

4 models 25 to 50 kW

AQUALIS INVERTER

2 models 5 to 12 kW

AQUACIAT POWERLD ILDLDH - LDC ILDH - ILDC4 models 300 to 500 kW

DUOLIS CALEO

1 model 4 to 10 kW

NA0407_200.qxd 18/02/2009 11:12 Page 4

Page 6: All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC CIATESA plant Acoustic chamber CIAT laboratory NA0407_200.qxd 18/02/2009 10:57 Page

CIATCOOLER LJALJAH10 models25 o 140 kW

C E N T R I F U G A L

CIATCOOLER TB ITB7 models 15 to 60 kW

Autonomous horizontalRL RLEIL ILE 12 models7 to 36 kW

Autonomous verticalRN RNEIN INE 16 models 12 to 72 kW

P A C K A G E D U N I T Sair/air air conditione

ROOF-TOP NEW SPACERPC IPC17 models 20 to 275 kW

hilled water production units

EO

NA0407_200.qxd 18/02/2009 11:18 Page 5

Page 7: All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC CIATESA plant Acoustic chamber CIAT laboratory NA0407_200.qxd 18/02/2009 10:57 Page

Heat pumps

al

Horizontal indoor unitRCH ICH3 200 to 25 300 m3/hup to 350 Pa

Vertical indoor unitRCV ICV3 200 to 14 600 m3/hup to 350 Pa

Centrifugal verticaloutdoor unit*RSV ISV 7 models 19 to 73 kW

Propeller outdoor unit*RSW RSW-SISW ISW-S 16 models 19 to 150 kW

BCPAquair6 models 22 to 66 kg/h5 500 to 16 000 m3/h

BCPJunior8 models4 to 15 kg/h1 200 to 5 500 m3/h

Pool dehumidifiers

T S S P L I T S Y S T E Mstatic pressure available

* Operates with CH or CV indoor units

ditioners and heat pumps

water/air air/waterHorizontal unit XHRXH IXH10 models7 to 41 kW

Ecociat3 models 10 to 30 kW

NA0407_200.qxd 18/02/2009 11:25 Page 6

Page 8: All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC CIATESA plant Acoustic chamber CIAT laboratory NA0407_200.qxd 18/02/2009 10:57 Page

AIR CONDENSATION

PROPELLER COOLING ONLY

CHILLED WATER PRODUCTION UNITS

WATER CONDENSATION

PROPELLER HEAT PUMPS AIR/WATER

AQUALIS2

N°Capacity R410A kW Dimensions (mm) Weight

Pf Pa lgth width ht. kg35 T 8,5 3,7 1035 350 657,4 8250 T 11,8 4,4 1035 350 1257 12065 T 14,7 5,0 1035 350 1257 14575 T 17,5 6,4 1035 350 1257 140

AQUACIAT2 LD-LDC-LDH

N°Capacity R410A kW Dimensions (mm) Weight

Pf Pa lgth width ht. kg80 V 19,7 6,9 1995 1055 1170 32690 V 22,4 8,1 1995 1055 1170 329100 V 26,3 9,0 1995 1055 1420 365120 V 29,9 10,6 1995 1055 1420 367150 V 38,9 13,7 1995 1055 1420 449180 V 46,7 14,8 1995 1055 1770 564200 V 53,1 18,1 1995 1055 1770 570240 V 61,0 20,5 1995 1055 1770 576300 V 76,8 27,7 1995 1055 1770 706350 V 92,5 30,9 2190 2129 2149 1046400 V 102,6 36,1 2190 2129 2149 1145500 V 123,9 46,2 2190 2129 2149 1183540 V 135,9 48,5 2740 2129 2149 1460600 V 151,1 55,8 2740 2129 2149 1596700 V 177,3 64,4 2740 2129 2149 1768702 V 189,3 60,3 2200 3698 2010 2135800 V 209,9 69,7 2200 3698 2010 2175900 V 250,9 81,5 2200 3698 2010 22151000 V 270,6 89,6 2200 3698 2010 22551100 V 291,5 100,2 2200 3698 2010 2310

AQUACIATPOWER LD-LDC-LDH

N°Capacity R410A kW Dimensions (mm) Weight

Pf Pa lgth width ht. kg1200 V 334 110 4260 2200 2200 34991500 V 380 127 4260 2200 2200 39571650 V 438 145 5626 2200 2200 45671800 V 493 163 5626 2200 2200 4621

POWERCIAT LX-LXC-LXH

N°Capacity R407C kW Dimensions (mm) Weight

Pf Pa lgth width ht. kg1200 236 102 2893 2200 2200 2667

1200HPS 261 110 2893 2200 2200 26671500 305 129 4260 2200 2200 3459

1500HPS 338 140 4260 2200 2200 34591850 362 155 4260 2200 2200 3908

1850HPS 409 171 4260 2200 2200 39082150 429 184 5626 2200 2200 4652

2150HPS 486 201 5626 2200 2200 46522500 522 215 5626 2200 2200 5177

2500HPS 594 237 5626 2200 2200 51772800 605 244 8358 2200 2200 6071

2800HPS 690 268 8358 2200 2200 60713050HPS 740 287 8358 2200 2200 69403400HPS 820 320 8358 2200 2200 73833750HPS 903 362 8358 2200 2200 78284200HPS 1076 413 11095 2200 2200 10074

POWERCIAT LX-LXC-LXH

N°Capacity

R134a kWDimensions (mm) Weight

Pf Pa lgth width ht. kg1800X 379 130 5626 2200 2260 4617

1800XHPS 403 131 5626 2200 2260 46172150X 456 154 5626 2200 2260 5240

2150XHPS 491 162 5626 2200 2260 52402500X 515 177 5626 2200 2260 5669

2500XHPS 571 193 5626 2200 2260 56692800X 602 198 8358 2200 2260 6688

2800XHPS 649 204 8358 2200 2260 66883050XHPS 738 236 8358 2200 2260 72953500XHPS 831 276 3858 2200 2260 73543600XHPS 877 284 9727 2200 2260 84353900XHPS 956 314 9727 2200 2260 85654200XHPS 992 318 11095 2200 2260 96604500XHPS 1029 338 11095 2200 2260 97204800XHPS 1080 357 11095 2200 2260 9740

Chilled water outlet temperature +7°CAir inlet temperature +35Dimensions and weight of the standard versions

AQUALIS2

N°Capacity R410A kW Dimensions (mm) Weight

Pf Pc lgth width ht. kg20 H(T) 5,3 6,1 1035 350 657,4 7328 H(T) 7,1 8,3 1035 350 657,4 7935 H(T) 8,5 10,2 1035 350 657,4 8250 H(T) 11,8 13,8 1035 350 1257 12065 HT 14,7 17,2 1035 350 1257 14575 HT 17,5 19,4 1035 350 1257 140

AQUALIS CALEO

N°Capacity R407C kW Dimensions (mm) Weight

Pc Pa lgth width ht. kg60H 13,66 3,75 1035 350 1257 126

60HT 13,67 3,3 1035 350 1257 12670HT 19,37 4,85 1035 350 1257 143

AQUACIAT2 ILD-ILDC-ILDH

N°Capacity R410A kW Dimensions (mm) Weight

Pf Pc lgth width ht. kg80 V 20,2 20,7 1995 1055 1170 32890 V 22,9 23,2 1995 1055 1170 331100 V 27,4 28,1 1995 1055 1420 366120 V 30,5 31,6 1995 1055 1420 368150 V 40,5 41,4 1995 1055 1420 452180 V 47,1 48,4 1995 1055 1770 611200 V 53,5 54,9 1995 1055 1770 614240 V 61,9 63,7 1995 1055 1770 620300 V 75,6 81,4 1995 1055 1770 756350 V 92,8 95,0 2190 2129 2149 1096400 V 105,2 108,8 2190 2129 2149 1195500 V 128,1 132,6 2190 2129 2149 1283540 V 139,9 147,1 2740 2129 2149 1570600 V 155,3 164,0 2740 2129 2149 1706700 V 163,1 181,5 2740 2129 2149 1878702 V 183,4 191,1 2200 3698 2010 2270800 V 201,8 213,5 2200 3698 2010 2320900 V 239,8 247,9 2200 3698 2010 23651000 V 257,9 265,2 2200 3698 2010 24451100 V 278,8 285,7 2200 3698 2010 2505

AQUACIATPOWER ILD-ILDC-ILDH

N°Capacity R410A kW Dimensions (mm) Weight

Pf Pc lgth width ht. kg1200 V 333 341 4260 2200 2200 35751500 V 382 387 4260 2200 2200 40331650 V 435 451 5626 2200 2200 46481800 V 488 503 5626 2200 2200 4707

CENTRIFUGAL COOLING ONLY

CIATCOOLER RTB

N°Capacity R407C kW Dimensions (mm) Weight

Pf Pa lgth width ht. kg80 16,1 7,6 1174 875 1227 24595 18,5 8,9 1174 875 1227 295120 23,9 11,8 1440 924 1312 328155 30,8 14,6 1440 924 1312 370195 37,0 17,7 2161 875 1227 502255 47,8 23,7 2704 924 1312 600315 61,6 29,2 2704 924 1312 695

CIATCOOLER LJA-LJAH

N°Capacity R407C kW Dimensions (mm) Weight

Pf Pa lgth width ht. kg100 23,7 8,5 1630 900 1990 581150 35,7 13,0 1630 900 1990 610200 45,0 18,2 2180 900 1990 771250 58,7 23,1 2180 900 1990 832300 69,8 27,3 2180 900 1990 859350 79,7 32,0 2830 900 1990 1165400 93,0 36,0 2830 900 1990 1220450 105,0 40,3 2830 900 1990 1261500 114,0 46,7 3460 900 1990 1462600 141,0 54,4 3460 900 1990 1517

CENTRIFUGAL HEAT PUMPS AIR/WATER

CIATCOOLER ITB

N°Capacity R407C kW Dimensions (mm) Weight

Pf Pc lgth width ht. kg80 16,1 18,7 1174 875 1227 25095 18,5 22,0 1174 875 1227 303120 23,9 28,7 1440 924 1312 340155 30,8 36,2 1440 924 1312 382195 37,0 44,0 2161 875 1227 516255 47,8 57,4 2704 924 1312 616315 61,6 72,4 2704 924 1312 708

AGEO CALEO TLB

N°Capacity R410A kW Dimensions (mm) Weight

Pc Pa lgth width ht. kg50H 16,6 3,2 650 695 1230 151

50HT 17,4 3,5 650 695 1230 15165HT 20,6 4,1 650 695 1230 16180HT 25,2 5,0 650 695 1230 165

DYNACIAT LG

N°Capacity R410A kW Dimensions (mm) Weight

Pf Pa lgth width ht. kg120 V 34,7 7,5 798 883 1201 230150 V 45,6 9,6 798 883 1201 300200 V 61,5 13 1492 883 1201 385240 V 69 15,2 1492 883 1201 390300 V 91,3 19,2 1492 883 1201 590350 V 105,1 22,3 1492 883 1201 620400 V 119,3 25,4 1492 883 1201 665500 V 147,8 32 1492 883 1201 735540 V 159,6 34,4 2380 883 1201 930600 V 182,4 38,4 2380 883 1201 1125753 Z 208 55 2200 880 1681 1045900 Z 249 67 2200 880 1681 12231000 Z 272 74 2200 880 1681 12231100 Z 315,2 78,3 2200 880 1681 13211200 Z 347 85,5 2200 880 1681 1413

DYNACIAT ILG

N°Capacity R410A kW Dimensions (mm) Weight

Pf Pc lgth width ht. kg120 V 29,2 38,9 798 883 1201 226150 V 38,0 50,8 798 883 1201 289200 V 50,8 67,9 1492 883 1201 379240 V 59,1 78,6 1492 883 1201 452300 V 77,0 101,5 1492 883 1201 595

HYDROCIAT LW

N°Capacity

R407C kWDimensions (mm) Weight

Pf Pc lgth width ht. kg1200B 266 79 3260 1130 2180 1910

1200BHPS 285 82 3260 1130 2180 19101500B 346 98 3595 1130 2180 2530

1500BHPS 368 100 3595 1130 2180 25301800B 428 119 3730 1130 2180 2820

1800BHPS 460 123 3730 1130 2180 28202150B 521 137 3700 1320 2197 3330

2150BHPS 555 141 3700 1320 2197 33302500B 624 162 3700 1320 2197 3860

2500BHPS 670 168 3700 1320 2197 38602800B 705 179 3700 1320 2197 3880

2800BHPS 755 186 3700 1320 2197 38803200BHPS 834 212 4195 1715 2274 52903400BHPS 887 226 4195 1715 2274 56403750BHPS 983 250 4195 1715 2274 59904200BHPS 1113 283 4195 1715 2274 6250

HYDROCIAT LW

N°Capacity

R134a kWDimensions (mm) Weight

Pf Pa lgth width ht. kg1800B 418 93 3800 1320 2450 3130

1800BHPS 433 96 3800 1320 2450 31302150B 492 110 4010 1320 2450 3520

2150BHPS 533 115 4010 1320 2450 35202500B 588 126 4010 1320 2450 3830

2500BHPS 625 134 4010 1320 2450 38302800B 661 140 4010 1320 2450 3840

2800BHPS 692 145 4010 1320 2450 38403050BHP 814 166 4700 1500 1900 4691

3500BHPS 921 193 4700 1500 1900 47193600BHPS 957 195 4700 1500 1900 51063900BHPS 1044 215 4700 1500 1900 52344200BHPS 1078 224 4700 1500 1900 52934500BHPS 1133 242 4700 1500 1900 53024800BHPS 1168 251 4700 1500 1900 5362

Chilled water outlet temperature +7°CCooling water outlet temperature +35°C

Cooling: water outlet +7°C / air +35°CHeating: water outlet +45°C / air +7°C BH

AQUACIAT CALEO

N°Capacity R407C kW Dimensions (mm) Weight

Pc Pa lgth width ht. kg80 Z 25,4 7,9 1995 1055 1423 370100 Z 35,5 10,4 1995 1055 1423 443120 Z 43 12,6 1995 1055 1423 456150 Z 49,1 14,2 1995 1055 1423 492

AQUACIAT INVERTER

N°Capacity R407C kW Dimensions (mm) Weight

Pc Pa lgth width ht. kg150 V 36,9 41,1 1995 1055 1423 450200 V 47,4 53,5 1995 1055 1423 620300 V - - 1995 1055 1423 750

AGEO ILB

N°Capacity R410A kW Dimensions (mm) Weight

Pf Pc lgth width ht. kg20 H(T) 5 6,8 650 695 1230 13330 H(T) 6,9 9,4 650 695 1230 13540H(T) 9,2 12,1 650 695 1230 13950 H 11,3 15,3 650 695 1230 154

50 HT 12,7 16 650 695 1230 15465 HT 15,5 19,8 650 695 1230 16480 HT 18,4 24,5 650 695 1230 168100 HT 23,2 31 650 695 1230 190120 HT 27,6 36,3 650 695 1230 195

NA0407_200.qxd 18/02/2009 11:02 Page 2

Page 9: All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC CIATESA plant Acoustic chamber CIAT laboratory NA0407_200.qxd 18/02/2009 10:57 Page

Weight

kg1910191025302530282028203330333038603860388038805290564059906250

Weight

kg313031303520352038303830384038404691471951065234529353025362

AIR / AIR SPLIT SYSTEM MONOBLOC AIR / AIR

XH HORIZONTAL UNIT

N°Air flow Capacity R407C kW Dimensions (mm) Weight

m3/h Pf Pc lgth width ht. kg25 1300 6,9 8,2 1024 866 431 12530 1500 7,7 9,0 1162 790 536 134

40M 2000 10,5 12,8 1162 790 536 15240 2000 10,5 12,8 1162 790 536 15250 2500 12,4 16,0 1408 946 587 20965 3100 16,0 19,5 1408 946 587 21780 4000 20,9 24,9 1825 1445 701 32395 4600 25,2 29,1 1825 1445 701 371120 6000 32,7 38,6 2496 1831 820 443155 7000 41,3 48,4 2496 1831 820 484

SW PROPELLER CONDENSATION UNIT

N°Capacity R407C kW Dimensions (mm) Weight Pf Pc lgth width ht. kg

80 19,0 18,7 1288 1000 915 17780 S 19,4 18,3 1288 1000 915 17790 S 20,8 19,8 1288 1000 915 204100 22,4 22,5 1288 1000 1223 2344

120 S 28,7 28,1 1288 1000 1223 237125 29,0 29,1 1288 1000 1223 249160 35,1 36,3 1288 1000 1523 273

160 S 35,6 36,1 1288 1000 1523 318185 S 43,2 41,9 1288 1000 1523 346195 45,4 446,2 1991 1018 1064 435255 59,4 60,6 1991 1018 1064 556315 74,6 76,4 1991 1018 1380 603450 1044,8 106,8 2222 2192 1294 975510 118,8 121,2 2222 2192 1294 1075570 140,7 134,5 2222 2192 1585 1095630 149,2 152,8 2222 2192 1585 1150

SV CENTRIFUGAL CONDENSATION UNIT

N°Capacity R407C kW Dimensions (mm) Weight Pf Pc lgth width ht. kg

80 18,9 19,4 1174 875 1227 25795 22,1 22,9 1174 875 1227 266120 28,6 29,6 1440 924 1312 325155 36,3 37,6 1440 924 1312 360195 44,2 45,8 2161 875 1227 475255 57,2 59,2 2704 924 1312 615315 72,6 75,2 2704 924 1312 659

CV VERTICAL INDOOR UNIT

N°Air flow

Compatible external units

Dimensions (mm) Weight

m3/h SW SV lgth width ht. kg80 4000 80 80 1030 720 1269 14095 4600 90 - 100 95 1030 720 1269 145120 6000 120S - 125 120 1360 720 1269 190155 7000 160 - 160S 155 1360 720 1269 194185 8650 185S195 9200 195 195 1976 720 1269 290255 12000 255 255 2636 720 1269 380315 14000 315 315 2636 720 1269 420

CH UNITE INTERIEURE HORIONTALE

N°Air flow

Compatible external units

Dimensions (mm) Weight

m3/h SW SV lgth width ht. kg80 4000 80 - 80S 80 1126 851 626 12295 4600 90S - 100 95 1126 851 626 130120 6000 120S - 125 120 1392 855 725 162155 7000 160 - 160S 155 1392 855 725 172185 8650 185S 2168 851 6631 170195 9200 195 195 2168 851 631 265255 12000 255 255 2686 855 730 350315 14000 315 315 2686 855 730 396450 18400 450 2778 2224 1092 550510 24000 510 2778 2224 1409 625570 24000 570 2778 2224 1409 665630 28000 630 2778 2224 1409 675

Pf : Cooling capacity Indoor air: 27°C 50% HR Outdoor air: 35°CPc : Heating capacity Indoor air: 21°C Outdoor air: 6°C

WATER/AIR HEAT PUMP

L/ LE HORIZONTAL UNIT

N°Air flow Capacity R407C kW Dimensions (mm) Weight

m3/h Pf Pc lgth width ht. kg30 1500 6,8 7,2 1294 965 530 170

40M 2000 8,4 9,5 1294 965 530 18740 2000 8,4 9,5 1294 965 530 18750 2500 11,6 11,7 1484 1105 575 23365 3100 15,0 15,4 1484 1105 575 252

80 /80 4000 18,9 / 17,9 19,4 / 18,4 1825 1445 701 35995 / 90 4600 22,1 / 19,3 22,9 / 20,2 1825 1445 701 405

120 /120 6000 28,6 / 26,8 29,6 / 27,8 2481 1911 820 480155 / 160 7000 36,3 / 34,8 37,6 / 36,5 2481 1911 820 530

N/NE VERTICAL UNIT

N°Air flow Capacity R407C kW Dimensions (mm) Weight

m3/h Pf Pc lgth width ht. kg50 2500 11,6 11,7 974 684 1542 25865 3100 15,0 15,4 974 684 1542 281

80 /80 4000 18,9/17,9 19,4/18,4 1174 885 1840 35995 / 90 4600 22,1/19,3 22,9/20,2 1174 885 1840 405120/120 6000 28,6/28,6 29,6/27,8 1440 934 2015 488155/160 7000 36,3/34,8 37,6/36,5 1440 934 2015 533195/180 9200 44,2/38,6 45,8/40,4 2161 885 1840 707255/240 12000 57,2/53,6 59,2/55,6 2704 885 2015 884315/320 14000 72,6/69,6 75,2/73,0 2704 934 2015 988

NEW SPACE

N° Air flow Capacity R410A kW Dimensions (mm) Weight m3/h Pf Pc lgth width ht. kg

90 4000 21,9 22,3 2400 1400 1497 489120 6000 30,3 30,7 2400 1400 1497 515160 8700 38,4 38,6 2400 1400 1675 555180 9000 41,7 44,3 2400 1400 1675 621240 12000 59,6 62,6 2610 2115 1705 828320 14300 74,4 76,3 2610 2115 1705 895360 15900 83,9 85,9 2610 2115 2005 1050420 18000 104,8 107,3 4816 2205 1795 1695485 18200 115,2 117,3 4816 2205 1795 1695540 20400 127,5 128,1 4816 2205 1795 1732600 24000 141,8 142,8 4816 2205 1795 1786650 27500 154,1 155,9 4816 2205 2095 2071720 30000 166,4 169,8 4816 2205 2095 2249840 33000 192,6 206,9 4816 2205 2095 2335960 37000 212,9 233,2 4816 2205 2095 23351100 42000 255,2 261 6316 2205 2095 28031200 46000 276,6 286,5 6316 2205 2095 2914

ROOFTOP

BCP JUNIOR

N°Air flow Capacity R407C kW Dimensions (mm) Weight

m3/h P. Déshu. Pc Récup. lgth width ht. kg20 1200 3,9 - 1430 658 636 16830 1500 5,1 - 1430 658 636 17240 2100 7,1 6,6 1530 838 700 20850 2600 8,7 8,2 1530 838 700 21260 3200 10,7 10,1 1530 838 700 22270 3700 12,6 11,8 1082 680 2143 30080 4300 14,3 13,5 1082 680 2143 30290 4600 15,2 14,3 1082 680 2143 329

SWIMMING - POOL DEHUMIDIFIERS

BCP AQUAIR

N°Air flow Capacity R407C kW Dimensions (mm) Weight

m3/h P. Déshu. Pc Récup. lgth width ht. kg110 5500 21,7 10,0 2070 1248 1315 630140 7000 27,3 16,9 2070 1248 1315 665180 9000 36,1 20,7 2282 1498 1613 895230 11500 44,6 24,9 2282 1498 1613 920265 13250 53,4 28,2 2450 1498 1813 1080320 16000 65,5 43,1 2450 1498 1813 1155

Pf : Cooling capacity Indoor air: 27°C 50% HR Outdoor air: 35°CPc : Heating capacity Indoor air: 21°C Outdoor air: 6°C

ECOCIAT

N°Air flow Capacity R410A kW Dimensions (mm) Weight

m3/h Pc Pa lgth width ht. kg30 V 2000 10,3 2,89 2227 1185 965 33850 V 3500 18,0 4,96 2227 1185 965 36390 V 5500 31,6 9,02 2227 1185 965 400

EXTRACTED AIR RECOVERY - WATER

Pc : Heating capacity Extracted air 22°C Water 48/55°CPa : Absorbed capacity

COOLING Indoor air: 27°C 50% HR Outdoor air: 35°CHEATING Indoor air: 21°C Outdoor air: 6°C

NA0407_200.qxd 18/02/2009 11:05 Page 3

Page 10: All solutions - EUROCONFORT - Partener CIAT in … plant Test platform CIAT laboratory Folding PLC CIATESA plant Acoustic chamber CIAT laboratory NA0407_200.qxd 18/02/2009 10:57 Page

CIAT centralair conditioning:

all-roundcompatibility

Air handling units, cassette type termi-nal units, fan coil or ductable units, theCIAT catalogue offers a range of com-plementary solutions to water chillersand heat pumps.These units cover all applications andmeet all situations encountered in theresidential, tertiary or industrial sectors.CIAT solutions offer high performances,are easy to implement and guaranteecontrolled comfort for the user.

CCooaaddiiss 22 cchhiilllleedd wwaatteerrccaasssseetttteeCoanda effect

TTeerrmmiinnaall uunniittDuctableMajor2 NCHUTA Compact

MMaajjoorr 330000ffaann ccooiill uunniittNCV / NCHUncased Vertical / Horizontal

AAiirr hhaannddlliinngg uunniittClimaciat Airtop / Airtech

MMaajjoorr 22 ffaann ccooiill uunniittCasedVertical / Horizontal

MMeellooddyy cchhiilllleedd wwaatteerrccaasssseetttteeFour-way

CCrriissttooppiiaaEnergy storage

NA

04.

07 E

This document is non-contractual. As part of its policy of continual product improvement, CIAT reserves the right to make any technical modification it feels appropriate without prior notification.

Head office & FactoriesAvenue Jean Falconnier - B.P. 1401350 - Culoz - FranceTel.: +33 (0)4 79 42 42 42 - Fax: +33 (0)4 79 42 42 10e-mail: [email protected] - www.ciat.com

CCompagnie IIndustrielle d’AApplications TThermiques - S.A. with a registered capital of 26 000 000 € - R.C.S. Belley B 545 620 114

NA0407_205.qxd 18/02/2009 11:46 Page 1