AIR QUALITY AND POLLUTION (TKA 3301) LECTURE NOTES 6- EQA 1974

26
ENVIRONMENTAL QUALITY ENVIRONMENTAL QUALITY (CLEAN AIR) REGULATIONS 1978 (CLEAN AIR) REGULATIONS 1978

description

AIR QUALITY AND POLLUTION (TKA 3301) LECTURE NOTESUNIVERSITY MALAYSIA TERENGGANU 2009Disclaimer: I don't own this document. If you believe you do, and you don't want it to be published here, please let me know. I will remove it immediately.

Transcript of AIR QUALITY AND POLLUTION (TKA 3301) LECTURE NOTES 6- EQA 1974

Page 1: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

ENVIRONMENTAL QUALITY ENVIRONMENTAL QUALITY (CLEAN AIR) REGULATIONS 1978(CLEAN AIR) REGULATIONS 1978

ENVIRONMENTAL QUALITY ENVIRONMENTAL QUALITY (CLEAN AIR) REGULATIONS 1978(CLEAN AIR) REGULATIONS 1978

Page 2: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974
Page 3: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Citation and commencement. Environmental Quality (Clean Air) Regulations

1978,

In these Regulations, unless the context otherwise requires -

"air impurities" - smoke, soot, dust, ash (including fly-ash), cinders, grit, solid particles of any kind inclusive of particulates, gases, fumes, mist, odors and radioactive substance – which affect adversely the human health or the living environment.

Page 4: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

a) any premises used for any industrial or trade purposes, or on which matter is burnt in connection with any industrial or trade purposes including burning of waste,

b) any facility or process that discharges or is capable of discharging air impurities into open air;

c) every chimney;d) every industrial plant; ande) every fuel burning equipment.

Page 5: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Must get written approval from DG first before new installations.

Not be installed within premises of the following class:

a. Designated as a residential zone – gazette in the local plan

b. such premises situated within a housing estate or situated within 1000 metres of the nearest dwelling house.

Page 6: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

type and design of incinerator must be approved by the DG.

Accompanying documents.a) site plans of approved scale and buildings within

1000 meters;b) proposed construction drawings, method of

charging and control equipment, and calculations and design parameters;

c) type and quantity of waste to be disposed and a combustion report on the waste sample

Page 7: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

a) Cannot be darker than that designated as shade No. I on the Ringelmann Chart; or

b) When observed or recorded with such instrument or device may not be darker than shade No. 1; or

c) Cannot cause obscuration to a degree equivalent to smoke darker than shade No. 1.

Page 8: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

1) Hold chart at arm's length to view smoke at source.

2) Source of light or sun should be behind the observer.

3) Match smoke as closely as possible to corresponding shade on chart.

Page 9: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

1) Permissible limit specified in regulation 14 shall be shade No. 2 on the Ringelmann Chart.

2) Existing facility emitting smoke shall comply with the requirement of paragraph (1) within six months from the date these Regulations come into force.

Page 10: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Regulations 14 and 15 shall not apply to the emission of smoke from a facility for a total of less than 5 minutes in one hour provided that the total period of such emissions shall not exceed an aggregate of 15 minutes in 24 hours.

Page 11: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Occupier to provide observation device

1. a smoke density indicator and alarm, installed so as to indicate adequately in the control room the density of smoke being discharged;

2. a window or other opening through which an unobstructed view of the top of the chimney may be obtained from the control room;

3. one or a series of mirrors so placed as to reflect the top of the opening or chimney, which reflection shall be visible from the control room;

4. a closed circuit television installation with the receiver located in the control room;

5. any other device that may be approved by the Director-General.

Page 12: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

1) Every new facility shall comply with Standard C.

2) Every existing facility shall comply with Standard A within two years and comply with Standard B within three years, from the date these Regulations come into force.

Page 13: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Solid particles concentration in Solid particles concentration in heating of metals.heating of metals.

Concentration at any point of dust, soot, ash, grit and any solid particles shall be such that the total mass before admixture with air, smoke, or other gases does not exceed Standard A: 0.3, Standard B: 0.25 and Standard C: 0.2 gramme in each normal cubic metre (Nm3) of effluent gases.

Page 14: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Solid particles concentration in other operations.

Concentration at any point of any smoke, soot, dust, ash (including fly ash) cinders, cement, lime, alumina, grit or other solid particles of any kind shall be such that the total mass of such solid particles before admixture with air, smoke or other gases does not exceed Standard A: 0.6, Standard B: 0.5, Standard C: 0.4, gramme in each normal cubic metre of effluent gases.

Page 15: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Metals and metallic compounds.

Substance Mercury Cadmium Lead Antimony

Std A 0.02 0.025 0.04 0.04

Std B 0.01 0.015 0.025 0.025

Std C 0.01 0.015 0.025 0.025

Arsenic Zinc Copper

0.04 0.15 0.15

0.025 0.1 0.1

0.025 0.1 0.1

Page 16: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Gaseous substanceGaseous substance

Page 17: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974
Page 18: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974
Page 19: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Asphalt concrete plant

Source Standard A Standard B Standard C

Stationary Plant

0.5 gm/Nm3

0.4 gm/Nm3

0.3 gm/Nm3

Mobile Plant

0.7 gm/Nm3

0.7 gm/Nm3

0.4 gm/Nm3

Page 20: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Portland cement plant

Source Standard A Standard B Standard C

Kiln 0.5 gm/Nm3 0.4 gm/Nm3 0.3 gm/Nm3

Clinker cooler, finish grinding and other

0.7 gm/Nm3 0.7 gm/Nm3 0.4 gm/Nm3

Page 21: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Portland Cement PlantPortland Cement Plant

Page 22: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974
Page 23: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974
Page 24: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Facilities discharging asbestos and free silica

Standard A Standard B Standard C

0.4 gm/Nm3 0.2 gm/Nm3 0.12 gm/Nm3

Page 25: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974

Types of Coal

Peat Lignite

Anthracite Coal

Page 26: AIR QUALITY AND POLLUTION (TKA 3301)  LECTURE NOTES 6- EQA 1974