AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or...

26
AIR CURTAINS / AIR DOORS 2018-2019

Transcript of AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or...

Page 1: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

AIR CURTAINS / AIR DOORS2018-2019

Page 2: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

ABOUTHEAT SAVING SYSTEMSHeat Saving Systems Inc. takes pride in supplying the highest quality air curtains to the market. Incorporating both functionality and elegant design, many years of development have gone into the current line of models. All the models have proven their durability over many years of reliable service, and are designed for maximum efficiency, performance and aesthetic appeal.

All of Heat Savings Systems air curtains conform to current technical standards and are ETL certified for all jurisdictions in North American. We have models to service all your light industrial and commercial applications, as well as several decorative units that will aesthetically fit into the front lobbies and entrances of offices, condominiums and institutional buildings.

Page 3: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains/ Air Doors.6 AC 100

7 AC 200

8 AC 300

10 AC 301

12 AC 400

14 AC 401

16 AC 402

18 AC 501

20 AC 1000

22 AC 1001

CONTENTS

General Information: Air Curtains/Air Doors.2 Utility and Cost Savings

2 Increased Building Efficiency

2 Model Specifications

2 Applications and Construction

3 Quick Reference Guide

4 Operating Conditions

4 Product Code Description

4 Control Panel

Page 4: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

Air Flow

2General Information: Air Curtains / Air Doors

When sizing a unit, must consider:• Size of opening• Exterior median low temperature• Interior ambient temperature

required• Building air systems…positive

or negative pressures• Exterior wind factors• Water systems – hot water temp.,

flows in litres or gallons per minute• Building or area volume• Pedestrian or commercial traffic

at entryway

Air Curtain / Air Door:

• Creates a barrier by blocking the entry of outside air into a building, or escaping air from the interior of the premises

• Minimizes the use of existing HVAC equipment to make up for heat losses or gains

• Will increase the efficiency of existing vestibules, or may replace the need for building one

• Improves employee efficiency by not having to stop to open and close doors

• Maintains comfortable ambient temperatures around entrances and doorways for both customer and employees

• Allows for open doors, to increase customer traffic in retail environments

• Dry off floors in entrance ways for safety

Heat Saving Systems manufactures the highest quality air curtains for whatever your requirements may be. Designed to protect against energy losses through openings, when correctly sized and installed efficiencies of up to 80% can be achieved, as compared to a space with no air curtain installed.

Utility and Cost Savings

Increased Building Efficiency

Heat Saving Systems has a complete range of models for all industrial, commercial and institutional applications, as well as several decorative units. Available as electric or water heated, or unheated (ambient).• Steel casing coated with high-

quality durable polymer coatings• Fans – cross flow impellers and

axial fans• Motors – external rotor for

superior cooling and heat dissipation, less vibration, motor and bearings sealed, higher efficiency and longer operating life

• Thermal protection – motors built-in, heating elements thermal relay protected

• Air curtain circuits are breaker protected

• Electric heating elements - straight stainless steel elements with stainless steel fins

• Water heated units – heat exchanger copper tubing with aluminum fins for efficient heat transfer. Rated for up to 70lbs psi. Equipped with drains in case of freezing risk

• All (non-decorative) units can be installed horizontally or vertically

• Complete with control panels• Decorative models available in

polished or matte stainless steel.Heat Saving Systems has a full range of air curtains for many applications, and have been installed and proven to be effective in all types of buildings and regional climates. Many factors must be considered when specifying a unit above and beyond the size of opening being considered, especially where high traffic areas, large area or volume buildings, extreme interior and exterior temperature variables, the intended use etc. For further information see “Model Selection Guide”, page 5.

Model Specifications Model Specifications

Applications and Construction

The various models are available in 39”, 59” and 79” and can be mounted in tandem, either horizontally or vertically to make up any opening size dimension. Each Air Curtain is supplied with Control Panel. Air curtains are energy saving devices, typically installed in a building over an exterior opening. An air curtain can function in two different ways.1. As a supplementary heater in an area air сurtain will maintain an ambient preset interior temperature in the immediate area making it more comfortable for customersor employees. 2. To block the transfer of air from exterior to interior. Usually requires more air and no heat. A more precise specification of model required. Typically for commercial or industrial applications, higher efficiencies are gained by blocking the air transfer in large buildings, or high traffic areas.

Page 5: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

3General Information: Air Curtains / Air Doors

Commercial and industrial Air Сurtains / Air Doors

QUICK REFERENCE GUIDE FOR AIR CURTAIN MODELS

Decorative Air Curtains / Air Doors

Page 6: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

4General Information: Air Curtains / Air Doors

Operating Conditions for Air Curtains Product Code Description

• Relative ambient air temperature, -4…+104 oF/ -20…+40 oC.• Air moisture level at no more than 80% at 68 oF (+20oC).• No dust or other airborne particles at concentrations exceeding

10 mg/m3.• There should be no condensation or presence of other airborne

substances that are aggressive to carbon steels (acids, alkalis), adhesives or flammable compounds, fibrous materials such as oleoresins or other industrial fibers.

• For Water Heated Air Curtains hot water is used as a heating agent, with the following characteristics:- operating pressure ≤ 1.2 MPa- temperature ≤ 302 oF (150 oC).

• Friquancy: 60 Hz.

ExampleAC300-79E21

AC Air Curtain 300 series

39, 59, 79 length in inches

E, W, A Electric, water, ambient

21 Heater power, kW

Control Panel for Air Curtains

Model: IR03

Components supplied:• Control Panel IR03• Infra-Red remote control with 8 m (26 ft) effective distance• Battery (3xAA 1.5V)• Bracket and fasteners• Instruction

Specifications:- Selection of Heating [Off / Heat stage 1 / Heat stage 1 & 2]- Selection of Fan speed [High / Med / Low]- Controlling temperature: 0-40°C (32 - 99°F)- Operating temperature: 5-35°C (40 - 95°F)- Accuracy: 0.5°C (1°F)- LCD display for temperature & heater indicator- Detecting element: thermistor NTC- Voltage supply: 208-230 VAC 50/60 Hz- Protection: IP20- Additional equipment: door activated or sensors

NOTE: Supplied standard on every model. Each is pre attached at the factory with 7 conductor 208v rated thermostat wiring (extendable)and operational once power is connected.

* The maximum current of the unit is shown at the rated voltage 208V.

208v electric heated models single 3ph wired. 600v and 480v electric heated models dual wired, corresponding 3ph wiring to the heating elements and 208v 1ph connection to the motors.

Page 7: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 SERIES:AIR CURTAINS / AIR DOORS

Page 8: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains / Air Doors

AC100SERIES

AVAILABLE OPTIONS

MODELS

AVAILABLE VOLTAGES

OVERVIEW

Electric Heated

Air Flow

6

208V~1 Ph

AVAILABLE OPTIONS

MODELS

SERIES

AVAILABLE VOLTAGES

OVERVIEW

Series 100 – compact stylish unit for use in smaller applications. A lower velocity unit with a 5 kW heater designed with built-in controls for ease of installation and operation. Ideal as a unit space heater or air curtain over a drive through window.

Electric Heated

31Е5

Electric Heated

Air Flow

GENERAL CHARACTERISTICS

MODEL АС100-31E5

Voltage V/PH/Hz 208/1/60

Heat Output kBTU/hkW

15.44.5

Air Volume cfmm³/h

295500

Мах. Door Height ftm

7.22.2

Temperature rise °F°C

82.428

Length ftmm

2.6785

Dimensions (L x W x H) inmm

30.9 х 7.5 х 8.9800 х 195 х 235

Weight lbkg

2310.5

Motor Input hpW

0.0748

Sound Level at 5 m (distance) dB(A) 45

Max. Current unit А 22.9

Page 9: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains / Air Doors

SERIES

AVAILABLE OPTIONS

MODELS

OVERVIEW

Air Flow

7

AC200

208V~3 Ph, 480V~3 Ph, 600V~3 PhAVAILABLE VOLTAGES

Electric Heated

Electric Heated

Series 200 – Lower velocity units rated for installation up to a maximum 6’ (1.8 m). Designed primarily for single doors or smaller vestibules. Ideal for drive through windows where a higher velocity may be required when mounting the unit farther from the window.

Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.

39E5

GENERAL CHARACTERISTICS

MODEL АС200-39E5

Heat Output kBTU/hkW

18.45.4

Air Volume cfmm³/h

8831500

Мах. Door Height ftm

8.22.5

Temperature rise °F°C

50.910.5

Length ftmm

3.31000

Dimensions (L x W x H) inmm

41 х 9 х 91040 х 225 х 225

Weight lbkg

33.115

Motor Input hpW

0.14100

Sound Level at 5 m (distance) dB(A) 52

*Max. Current unit (208V) А 16.1

Maximum motor current А 0.5

*Max. Current heating elements480 V600 V

А6.95.6

* See page 6.

Air Flow

OVERVIEW

Page 10: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains / Air Doors

Electric Heated | Water Heated | Ambient (Unheated)

SERIES

AVAILABLE OPTIONS

MODELS

AVAILABLE VOLTAGES

OVERVIEW

Electric Heated

8

208V~3 Ph, 480V~3 Ph, 600V~3 Ph

Electric Heated

39E8, 59E13, 79E16 | 39W12, 59W20, 79W28 | 39A, 59A, 79А

AC300

Air Flow

Series 300 - Elegant in design for retail and commercial applications. Designed for pedestrian entrances, with or without vestibules. Available in 39” for a single door, 59” and 79” for double swinging or sliding doors, or install in tandem for larger installs.

Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.

GENERAL CHARACTERISTICS

MODEL АС300-39E8 АС300-59E13 АС300-79E16

Heat Output kBTU/hkW

27.38.0

45.713.4

54.916.1

Air Volume cfmm³/h

10301750

15902700

20913550

Мах. Door Height ftm

11.53.5

Temperature rise °F°C

57.214

59.015

57.214

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

42 х 12.8 х 10.41070 х 325 х 265

61.4 х 12.8 х 10.41560 х 325 х 265

79.3 х 12.3 х 10.72015 х 325 х 265

Weight lbkg

4219

6529.5

79.536

Motor Input hpW

0.29210

0.57420

0.57420

Sound Level at 5 m (distance) dB(A) 54 54 57

*Max. Current unit (208V) А 24.4 41.1 48.9

Maximum motor current А 1 2 2

*Max. Current heating elements480 V600 V

А10.18.1

16.413.1

20.216.2

* See page 6.

OVERVIEW

Page 11: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

9

Ambient (Unheated)

Air Flow

Air Flow

GENERAL CHARACTERISTICS

MODEL АС300-39W12 АС300-59W20 АС300-79W28

Voltage V/PH/Hz 208/1/60

Heat Output kBTU/hkW

39.211.5

67.619.8

93.527.4

Air Volume cfmm³/h

9721650

14722500

19433300

Мах. Door Height ftm

11.53.5

Temperature rise °F°C

75.224

78.826

80.627

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

42 х 12.8 х 10.41070 х 325 х 265

61.4 х 12.8 х 10.41560 х 325 х 265

79.3 х 12.3 х 10.72015 х 325 х 265

Weight lbkg

4219

66.230

79.536

Motor Input hpW

0.29210

0.57420

0.57420

Max. Сurrent А 1.1 2.2 2.2

Sound Level at 5 m (distance) dB(A) 52 53 56

GENERAL CHARACTERISTICS

MODEL АС300-39А АС300-59А АС300-79А

Voltage V/PH/Hz 208/1/60

Air Volume cfmm³/h

10301750

15902700

20913550

Мах. Door Height ftm

11.53.5

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

42 х 12.8 х 10.41070 х 325 х 265

61.4 х 12.8 х 10.41560 х 325 х 265

79.3 х 12.3 х 10.72015 х 325 х 265

Weight lbkg

26.512

5525

66.230

Motor Input hpW

0.29210

0.57420

0.57420

Max. Сurrent А 1.1 2.2 2.2

Sound Level at 5 m (distance) dB(A) 52 53 56

THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)

MODEL АС300-39W12

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

39.211.5

31.49.2

10.63.1

Air Temperature rise °F°C

75.224

66.219

42.86

Water Flow USGPHl/s

123.640.13

114.130.12

38.040.04

MODEL АС300-59W20

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

67.619.8

54.616.0

27.38.0

Air Temperature rise °F°C

78.826

71.622

6820

Water Flow USGPHl/s

188.740.20

199.740.21

104.620.11

MODEL АС300-79W28

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

93.527.4

75.422.1

41.612.2

Air Temperature rise °F°C

80.627

73.423

55.413

Water Flow USGPHl/s

285.340.30

285.340.30

152.180.16

* Based on inlet/outlet and outlet water temperatures of 203 °F/128 °F (95°С/70°С)

Water Heated

AC300

Page 12: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains / Air Doors

SERIES

AVAILABLE OPTIONS

MODELS

AVAILABLE VOLTAGES

10

208V~3 Ph, 480V~3 Ph, 600V~3 Ph

Series 301 - Designed specifically for installations into standard drop ceilings of up to 11’ (3.5m) in height, but can be utilized wherever a flush mounted air curtain will be required for commercial, retail or institutional applications.

Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.

39E8, 59E13, 79E16 | 39W12, 59W20, 79W28 | 39А, 59А, 79А

Electric Heated | Water Heated | Ambient (Unheated)

AC301

OVERVIEW

Electric Heated

Air Flow

GENERAL CHARACTERISTICS

MODEL АС301-39E8 АС301-59E13 АС301-79E16

Heat Output kBTU/hkW

27.38.0

44.413.0

54.616.0

Air Volume cfmm³/h

10301750

15902700

10313550

Мах. Door Height ftm

11.53.5

Temperature rise °F°C

57.214

57.214

56.313.5

Length ftmm

3.21000

4.91500

6.52000

Dimensions (L x W x H) inmm

41.6 х 20.6 х 9.31170 х 525 х 235

65.8 х 20.6 х 9.31170 х 525 х 235

83.1 х 20.6 х 9.32110 х 525 х 235

Weight lbkg

66.230

94.943

113.751.5

Motor Input hpW

0.31230

0.62460

0.62460

Sound Level at 5 m (distance) dB(A) 54 55 57

*Max. Current unit (208V) А 24.4 41 49

Maximum motor current А 1 2 2

*Max. Current heating elements480 V600 V

А10.18.1

16.413.1

20.216.2

* See page 6.

Page 13: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

11AC301

Water Heated

Air Flow

GENERAL CHARACTERISTICS

MODEL АС301-39W12 АС301-59W20 АС301-79W28

Voltage V/PH/Hz 208/1/60

Heat Output kBTU/hkW

39.2411.5

68.2420

93.9427.4

Air Volume cfmm³/h

9711650

14722500

19423300

Мах. Door Height ftm

11.53.5

Temperature rise °F°C

75.224

78.826

80.627

Length ftmm

3.31000

4.91500

6.562000

Dimensions (L x W x H) inmm

46.1 х 21.9 х 9.31170 х 555 х 235

65.8 х 21.9 х 8.91670 х 555 х 225

83.1 х 21.9 х 9.32110 х 555 х 235

Weight lbkg

76.230.5

98.144.5

111.350.5

Motor Input hpW

0.278200

0.54400

0.536400

Max. Сurrent А 1.0 2.0 2.0

Sound Level at 5 m (distance) dB(A) 53 54 55

THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)

MODEL АС301-39W12

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

39.2511.5

31.409.2

10.583.1

Air Temperature rise °F°C

75.224

66.219

42.86

Water Flow USGPHl/s

123.650.13

114.130.12

38.040.04

MODEL АС301-59W20

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

67.5619.8

54.5916

27.308

Air Temperature rise °F°C

78.826

71.622

68.020

Water Flow USGPHl/s

188.740.2

199.740.21

104.620.11

MODEL АС301-79W28

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

93.5227.4

75.4322.1

41.612.2

Air Temperature rise °F°C

81.327

73.423

55.413

Water Flow USGPHl/s

285.340.30

285.340.30

152.180.16

* For water heaters this is 203 °F/128 °F (95°С/70°С) hot water

Ambient (Unheated) GENERAL CHARACTERISTICS

MODEL АС301-39А АС301-59А АС301-79А

Voltage V/PH/Hz 208/1/60

Air Volume cfmm³/h

10301750

15892700

20893550

Мах. Door Height ftm

11.53.5

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

46.1 х 20.6 х 9.31170 х 525 х 235

65.8 х 20.6 х 9.31670 х 525 х 235

83.1 х 20.6 х 9.32110 х 525 х 235

Weight lbkg

59.527

8639

10045.5

Motor Input hpW

0.29220

0.59440

0.59440

Max. Сurrent А 1.1 2.0 2.1

Sound Level at 5 m (distance) dB(A) 54 55 57

Air Flow

Page 14: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains / Air Doors

SERIES

AVAILABLE OPTIONS

MODELS

AVAILABLE VOLTAGES

OVERVIEW

Air Flow

12

Electric Heated | Water Heated | Ambient (Unheated)

208V~3 Ph, 480V~3 Ph, 600V~3 Ph

Series 400 – Higher output units for high pedestrian traffic areas, larger volume buildings i.e. malls, recreational facilities, smaller warehouse bay doors. Available heated (electric or water) or unheated.Versatile in many different commercial or industrial applications. Installation up to a maximum 16’ (5 m).

39E8, 59E16, 79E16 | 39W20, 59W32, 79W47 | 39A, 59A, 79A

AC400

Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.

GENERAL CHARACTERISTICS

MODEL АС400-39E8 АС400-59E16 АС400-79E16

Heat Output kBTU/hkW

27.38.0

54.616.0

54.916.1

Air Volume cfmm³/h

15902700

23564000

35346000

Мах. Door Height ftm

16.45.0

Temperature rise °F°C

46.58

53.612

48.29

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

43.7 х 13.8 х 13.41110 х 350 х 340

62 х 13.8 х 13.41575 х 350 х 340

82.3 х 13.8 х 13.42090 х 350 х 340

Weight lbkg

56.225.5

89.440.5

101.546.0

Motor Input hpW

0.54400

1.22900

1.22900

Sound Level at 5 m (distance) dB(A) 60 65 66

*Max. Current unit (208V) A 25.5 51.2 50.7

Maximum motor current А 2.1 4.3 3.8

*Max. Current heating elements480 V600 V

А10.18.1

20.216.2

20.216.2

* See page 6.

Electric Heated

OVERVIEW

Air Flow

Page 15: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

Ambient (Unheated)

13AC400

Water Heated

Air Flow

Air Flow

GENERAL CHARACTERISTICS

MODEL АС400-39W20 АС400-59W32 АС400-79W47

Voltage V/PH/Hz 208/1/60

Heat Output kBTU/hkW

68.320.0

109.232.0

161.847.4

Air Volume cfmm³/h

15312600

20023400

30625200

Мах. Door Height ftm

16.45.0

Temperature rise °F°C

98.637

78.826

80.627

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

43.7 х 13.8 х 13.41110 х 350 х 340

62 х 13.8 х 13.41575 х 350 х 340

82.3 х 13.8 х 13.42090 х 350 х 340

Weight lbkg

68.531

91.641.5

11753

Motor Input hpW

0.61450

0.87640

1.22690

Max. Сurrent А 2.2 3 3.8

Sound Level at 5 m (distance) dB(A) 64 64 65

THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)

MODEL

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

66.219.4

52.615.4

16.54.9

Air Temperature rise °F°C

98.637

91.433

69.821

Water Flow USGPHl/s

2000.21

2000.21

570.06

MODEL

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

109.232

88.125.8

45.113.2

Air Temperature rise °F°C

78.826

69.821

51.811

Water Flow USGPHl/s

332.890.35

332.890.35

171.200.18

MODEL

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

161.847.4

130.738.3

73.021.4

Air Temperature rise °F°C

80.627

71.622

53.612

Water Flow USGPHl/s

494.580.52

494.580.52

275.830.29

* Based on inlet/outlet and outlet water temperatures of 203 °F/128 °F (95°С/70°С)

GENERAL CHARACTERISTICS

MODEL АС400-39А АС400-59А АС400-79А

Voltage V/PH/Hz 208/1/60

Air Volume cfmm³/h

15312600

20023400

30625200

Мах. Door Height ftm

16.45.0

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

43.7 х 13.8 х 13.41110 х 350 х 340

62 х 13.8 х 13.41575 х 350 х 340

82.3 х 13.8 х 13.42090 х 350 х 340

Weight lbkg

61.828

78.335.5

101.546

Motor Input hpW

0.61450

0.87640

1.22710

Max. Сurrent А 2.2 3.0 3.5

Sound Level at 5 m (distance) dB(A) 64 64 65

Page 16: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains / Air Doors

SERIES

AVAILABLE OPTIONS

MODELS

AVAILABLE VOLTAGES

OVERVIEW

14

Electric Heated | Water Heated | Ambient (Unheated)

208V~3 Ph, 480V~3 Ph, 600V~3 Ph

Air Flow

Electric Heated

39E16, 59E21, 79E21 | 39W20, 59W32, 79W47 | 39A, 59A, 79A

AC401

GENERAL CHARACTERISTICS

MODEL АС401-39Е16 АС401-59E21 АС401-79E21

Heat Output kBTU/hkW

54.616

71.621

71.621

Air Volume cfmm³/h

15892700

23544000

35316000

Мах. Door Height ftm

16.45.0

Temperature rise °F°C

63.517.5

59.915.5

50.910.5

Length ftmm

3.281000

4.921500

6.562000

Dimensions (L x W x H) inmm

49.1 х 25 х 11.81250 х 635 х 300

61.7 х 25 х 11.81705 х 635 х 300

87.5 х 25 х 11.82220 х 635 х 300

Weight lbkg

90.441

132.260

157.671.5

Motor Input hpW

0.60450

1.21900

1.21900

Sound Level at 5 m (distance) dB(A) 63 65 66

*Max. Current unit (208V) A 48.9 35.4+31.4 35.4+31.4

Maximum motor current А 2 4 4

*Max. Current heating elements480 V600 V

А20.216.2

27.822.3

27.822.3

* See page 6.

OVERVIEW

Series 401 - Designed specifically for installations into standard drop ceilings of up to 11’ (3.5m) in height, but can be utilized wherever a flush mounted air curtain will be required for commercial, retail or institutional applications. Installation up to a maximum 16.4’ (5 m).

Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.

Page 17: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

15

Air Flow

AC401

Water Heated

Air Flow

GENERAL CHARACTERISTICS

MODEL АС401-39W20 АС401-59W32 АС401-79W47

Voltage V/PH/Hz 208/1/60

Heat Output kBTU/hkW

68.220

109.232

161.747.4

Air Volume cfmm³/h

15302600

20013400

30605200

Мах. Door Height ftm

16.45.0

Temperature rise °F°C

98.637

78.826

80.627

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

49.1 х 25.6 х 11.81245 x 650 x 300

67.1 х 25.6 х 11.81705 x 650 x 300

87.5 х 25.6 х 11.82225 x 650 x 300

Weight lbkg

92.642

130.059

160.973

Motor Input hpW

0.6450

1.2900

1.2900

Max. Сurrent А 2.2 4.0 4.2

Sound Level at 5 m (distance) dB(A) 63 65 66

THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)

MODEL АС401-39W20

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

66.219.4

52.615.4

16.54.9

Air Temperature rise °F°C

98.637

91.433

63.821

Water Flow USGPHl/s

2000.21

2000.21

570.06

MODEL АС401-59W32

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

109.232

88.125.8

45.113.2

Air Temperature rise °F°C

78.826

69.821

51.811

Water Flow USGPHl/s

332.890.35

332.890.35

171.200.18

MODEL АС401-79W47

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

161.847.4

130.738.3

73.021.4

Air Temperature rise °F°C

80.627

71.622

53.612

Water Flow USGPHl/s

494.580.52

494.580.52

275.830.29

* For water heaters this is 203 °F/128 °F (95°С/70°С) hot water

Ambient (Unheated) GENERAL CHARACTERISTICS

MODEL АС401-39А АС401-59А АС401-79А

Voltage V/PH/Hz 208/1/60

Air Volume cfmm³/h

15302600

20013400

30615200

Мах. Door Height ftm

16.45.0

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

49.1 х 25 х 11.81250 х 635 х 300

67.1 х 25 х 11.81705 х 635 х 300

87.5 х 25 х 11.82220 х 635 х 300

Weight lbkg

82.737.5

120.254.5

144.465.5

Motor Input hpW

0.29210

0.57420

0.57420

Max. Сurrent А 2.2 4.0 4.2

Sound Level at 5 m (distance) dB(A) 63 65 66

Air Flow

Page 18: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains / Air Doors

SERIES

AVAILABLE OPTIONS

MODELS

AVAILABLE VOLTAGES

OVERVIEW

16

208V~3 Ph, 480V~3 Ph, 600V~3 Ph

Electric Heated | Water Heated | Ambient (Unheated)

Electric Heated

Air Flow

39E16, 59E21, 79E32 | 39W22, 59W41, 79W54 | 39А, 59А, 79А

AC402

Control panel included with every air curtain.Complete with 3-speed control, Thermostatand 2 heat settings. Installation up to a maximum 16.4’ (5 m).

GENERAL CHARACTERISTICS

MODEL АС402-39E16 АС402-59E21 АС402-79E32

Heat Output kBTU/hkW

54.616

71.621

109.232

Air Volume cfmm³/h

19423300

33555700

38266500

Мах. Door Height ftm

18.05.5

Temperature rise °F°C

58.114.5

51.811.0

51.814.5

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

44.4 х14.7 х 16.71130 х 375 х 425

71.2 х14.7 х 16.71810 х 375 х 425

83.2 х14.7 х 16.72115 х 375 х 425

Weight lbkg

63.929

103.647

114.652

Motor Input hpW

0.6450

1.2900

1.2900

Sound Level at 5 m (distance) dB(A) 64 66 67

*Max. Current unit (208V) A 49 66.5 98

Maximum motor current А 2 4 4

*Max. Current heating elements480 V600 V

А20.216.2

27.822.3

40.432.2

* See page 6.

OVERVIEW

Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.

Page 19: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

17

Air Flow

AC402

Water Heated

Air Flow

GENERAL CHARACTERISTICS

MODEL АС402-39W22 АС402-59W41 АС402-79W54

Voltage V/PH/Hz 208/1/60

Heat Output kBTU/hkW

78.523

144.342.3

187.354.9

Air Volume cfmm³/h

19423300

30605200

38266500

Мах. Door Height ftm

185.5

Temperature rise °F°C

68.920.5

7523.9

76.824.9

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

44.4 х 14.7х 16.71130 х 375 х 425

71.2 х 14.7х 16.71810 х 375 х 425

83.2 х 14.7х 16.72115 х 375 х 425

Weight lbkg

6530

10146

11854

Motor Input hpW

0.6450

1.2900

1.2900

Max. Сurrent А 2.2 4.2 4.2

Sound Level at 5 m (distance) dB(A) 64 66 67

THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)

MODEL АС402-39W22

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

78.523.0

62.418.3

17.75.2

Air Temperature rise °F°C

68.920.5

61.316.3

40.34.6

Water Flow USGPHl/s

2380.25

2380.25

670.07

MODEL АС402-59W41

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

144.342.3

116.434.1

62.818.4

Air Temperature rise °F°C

7524

6719

5110

Water Flow USGPHl/s

437.50.46

437.50.46

237.780.25

MODEL АС402-79W54

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

187.454.9

151.244.3

84.624.8

Air Temperature rise °F°C

76.825

68.220

52.111

Water Flow USGPHl/s

570.70.6

570.70.6

313.90.3

* Based on inlet/outlet and outlet water temperatures of 203 °F/128 °F (95°С/70°С)

Ambient (Unheated) GENERAL CHARACTERISTICS

MODEL АС402-39А АС402-59А АС402-79А

Voltage V/PH/Hz 208/1/60

Air Volume cfmm³/h

19423300

35326000

38266500

Мах. Door Height ftm

185.5

Length ftmm

3.31000

4.91500

6.62000

Dimensions (L x W x H) inmm

44.4 х 14.7 х 16.71130 х 375 х 425

71.2 х 14.7 х 16.71810 х 375 х 425

83.2 х 14.7 х 16.72115 х 375 х 425

Weight lbkg

55.125

87.139.5

100.345.5

Motor Input hpW

0.6450

1.2900

1.2900

Max. Сurrent А 2.2 4.2 4.2

Sound Level at 5 m (distance) dB(A) 64 66 67

Air Flow

Page 20: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains / Air Doors

SERIES

AVAILABLE OPTIONS

MODELS

AVAILABLE VOLTAGES

OVERVIEW

18

208V~3 Ph, 480V~3 Ph, 600V~3 Ph

Electric Heated | Water Heated | Ambient (Unheated)

Electric Heated

Air Flow

59E32, 79E32 | 59W69, 79W100 | 59А, 79А

AC501

Control panel included with every air curtain.Complete with 3-speed control, Thermostatand 2 heat settings. Installation up to a maximum 16.4’ (5 m).

GENERAL CHARACTERISTICS

MODEL АС501-59E32 АС501-79E32

Heat Output kBTU/hkW

109.232

109.232

Air Volume cfmm³/h

44737600

647411000

Мах. Door Height ftm

19.76.0

Temperature rise °F°C

54.512.5

47.38.5

Length ftmm

4.91500

6.62000

Dimensions (L x W x H) inmm

63.8 х 19.7 х 18.91620 х 500 х 480

83.4 х 18.9 х 19.72120 х 480 х 500

Weight lbkg

16273.5

18182

Motor Input hpW

2.141600

2.141600

Sound Level at 5 m (distance) dB(A) 69 69

*Max. Current unit (208V) A 102 102

Maximum motor current А 8 8

*Max. Current heating elements480 V600 V

А40.432.2

40.432.2

* See page 6.

OVERVIEW

Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.

Page 21: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

19

Air Flow

Air Flow

AC501

Water Heated

Air Flow

GENERAL CHARACTERISTICS

MODEL АС501-59W69 АС501-79W100

Voltage V/PH/Hz 208/1/60

Heat Output kBTU/hkW

246.372

367.1106

Air Volume cfmm³/h

38856600

57099700

Мах. Door Height ftm

19.76.0

Temperature rise °F°C

90.032

90.733

Length ftmm

4.91500

6.62000

Dimensions (L x W x H) inmm

63.8 х 19.4 х 19.71620 х 495 х 500

83.4 х 19.5 х 19.72120 х 495 х 500

Weight lbkg

17278

20392

Motor Input hpW

2.141600

2.141600

Max. Сurrent А 8 8

Sound Level at 5 m (distance) dB(A) 68 68

THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)

MODEL АС501-59W69

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

246.472.2

201.359.0

106.831.3

Air Temperature rise °F°C

89.932.2

78.625.9

57.214

Water Flow USGPHl/s

751.40.8

751.40.8

399.50.4

MODEL АС501-79W100

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

367.2107.6

296.286.8

168.949.5

Air Temperature rise °F°C

90.732.6

79.526.4

59.015.0

Water Flow USGPHl/s

1112.81.2

1122.31.2

637.30.7

* Based on inlet/outlet and outlet water temperatures of 203 °F/128 °F (95°С/70°С)

Ambient (Unheated) GENERAL CHARACTERISTICS

MODEL АС501-59А АС501-79А

Voltage V/PH/Hz 208/1/60

Air Volume cfmm³/h

45917800

659211200

Мах. Door Height ftm

19.76

Length ftmm

4.91500

6.62000

Dimensions (L x W x H) inmm

63.8 х 18.9 х 19.71620 х 480 х 500

83.4 х 18.9 х 19.72120 х 480 х 500

Weight lbkg

14968

17278

Motor Input hpW

2.141600

2.141600

Max. Сurrent А 8 8

Sound Level at 5 m (distance) dB(A) 69 69

Page 22: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains / Air Doors

SERIES

AVAILABLE OPTIONS

MODELS

AVAILABLE VOLTAGES

20

208V~3 Ph, 480V~3 Ph, 600V~3 Ph

Electric Heated | Water Heated

Electric Heated

Air Flow

39E16, 79E21 | 39W20, 79W50

AC1000

Series 1000 – Higher output decorative air curtain designed to be both functional and have the ability to suit different styles of architecture, from traditional to more modern retail or commercial environments. Available in soft white painted finish, optional polished or brushed stainless steel.

Control panel included with every air curtain.Complete with - 3 speed control,Thermostat and 2 heat settings.

GENERAL CHARACTERISTICS

MODEL АС1000-39E16 АС1000-79E21

Heat Output kBTU/hkW

54.916.1

73.421.5

Air Volume cfmm³/h

17072900

34155800

Мах. Door Height ftm

11.53.5

Temperature rise °F°C

60.816

51.811

Length ftmm

3.31000

6.62000

Dimensions (L x W x H) inmm

43.5 х 35 х 15.61105 х 890 х 395

82.9 х 35 х 15.62105 х 890 х 395

Weight lbkg

9945

16173

Motor Input hpW

0.61450

1.22900

Sound Level at 5 m (distance) dB(A) 60 63

*Max. Current unit (208V) A 49.1 66.8

Maximum motor current А 2.2 4.3

*Max. Current heating elements480 V600 V

А20.216.2

27.822.3

* See page 6.

OVERVIEW

Page 23: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

21

Air Flow

AC1000

Water Heated

Air Flow

GENERAL CHARACTERISTICS

MODEL АС1000-39W20 АС1000-79W50

Voltage V/PH/Hz 208/1/60

Heat Output kBTU/hkW

7020.5

17250.4

Air Volume cfmm³/h

15902700

32305500

Мах. Door Height ftm

11.53.5

Temperature rise °F°C

71.622

87.831

Length ftmm

3.31000

6.62000

Dimensions (L x W x H) inmm

43.5 х 35 х 15.61105 х 890 х 395

82.9 х 35 х 15.62105 х 890 х 395

Weight lbkg

9945

16173

Motor Input hpW

0.61450

1.22900

Max. Сurrent А 4 8

Sound Level at 5 m (distance) dB(A) 57 60

THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)

MODEL АС1000-39W20

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

7020.5

55.616.3

175

Air Temperature rise °F°C

71.622

64.418

415

Water Flow USGPHl/s

209.20.22

209.20.22

62.80.066

MODEL АС79W50

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

172.050.4

138.640.6

76.522.4

Air Temperature rise °F°C

87.831

7725

57.214

Water Flow USGPHl/s

504.100.53

513.610.54

285.340.30

* For water heaters this is 203 °F/128 °F (95°С/70°С) hot water

Page 24: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

2018-2019 Series: Air Curtains / Air Doors

SERIES

AVAILABLE OPTIONS

MODELS

AVAILABLE VOLTAGES

22

208V~3 Ph, 480V~3 Ph, 600V~3 Ph

Electric Heated | Water Heated

OVERVIEWSeries 1001- a popular model for installation where a decorative, but very functional application is required. These units are floor mounted and stand 79` high. Suitable for installing as a stand alone unit or as a pair can protect across several doors simultaneously. Available also in polished or brushed stainless steel finishes and are ideal in any style of public accessed building.

79E16 | 79W24

AC1001

Control panel included with every air curtain.Complete with - 3 speed control, Thermostat and 2 heat settings.

Page 25: AIR CURTAINS / AIR DOORS - Heat Saving Systems Ltd.€¦ · • Building air systems…positive or negative pressures • Exterior wind factors • Water systems – hot water temp.,

23AC1001

Water Heated

Air Flow

Electric Heated GENERAL CHARACTERISTICS

MODEL АС1001-76Е16

Heat Output kBTU/hkW

54.916.1

Air Volume cfmm³/h

20003400

Мах. Door Height ftm

7.02.1

Temperature rise °F°C

57.214

Length ftmm

11.53500

Dimensions (L x W x H) inmm

(w)18.1 (H)79.2(w) 460 (H) 2012

Weight lbkg

161.273

Motor Input hpW

0.46340

Sound Level at 5 m (distance) dB(A) 54

*Max. Current unit (208V) A 48.5

Maximum motor current А 1.6

*Max. Current heating elements480 V600 V

А20.216.2

* See page 6.

Air Flow

GENERAL CHARACTERISTICS

MODEL АС1001-79W24

Voltage V/PH/Hz 208/1/60

Heat Output kBTU/hkW

82.024.0

Air Volume cfmm³/h

17703000

Мах. Door Height ftm

7.02.1

Temperature rise °F°C

8630

Length ftmm

11.53500

Dimensions inmm

(W) 18.1 (H) 79.2(W) 460 (H) 2012

Weight lbkg

143.565

Motor Input hpW

0.49360

Max. Сurrent А 1.7

Sound Level at 5 m (distance) dB(A) 54

THERMAL CHARACTERISTICS (Thermal characteristics at ambient room temperature 59°F (15°C) and maximum airow)

MODEL АС1001-79W24

Water Temperature at Inlet/Outlet °F°C

203/15895/70

176/14080/60

140/10460/40

Heat Output kBTU/hkW

81.924.0

66.219.4

37.511.0

Air Temperature rise °F°C

5430

43.224

25.214

Water Flow USGPHl/s

237.780.25

247.290.26

133.160.14

* Based on inlet/outlet and outlet water temperatures of 203 °F/128 °F (95°С/70°С) hot water