    For many in the air conditioning industry, modular chillers are a dream come true. As cooling and airconditioning systems continue to age and the demand on them rises, chiller conversion andreplacement decisions are imminent for most building and facility managers. There are many options

    to choose from and choosing the right solution means a lot of research. When it comes to buildingrenovations, retrofits, or the replacing of existing cooling systems that are either too expensive torepair or operate, modular chillers are often the perfect solution. Our modular chillers are a popularalternative to conventional chilling systems for three main reasons: low installation costs, lowoperating costs and low maintenance or repair costs.

    1. Low installation costsare an important consideration for anyone who has to install a coolingsystem in the basement of an older building or in a mechanical room on the top floor of a multi-storybuilding without altering the building. This applies to anyone, for that matter, who has to install an air

    conditioning system in a place that is hard to reach without major renovations. Modular chillers can beinstalled without any significant interruption to your business and without incurring the enormous costof renovating your building. Because of their small footprint, they can easily fit through most standarddoorways, hallways or stairwells and even in the smallest of equipment rooms. You won't need anyspecial moving equipment, except perhaps a dolly, and these modular chillers are compatible withmost existing water piping systems.

    2. Low operation costsare just as important, if you want a cooling system that is energy efficient,expandable, reliable, quiet and environmentally friendly. A modular chiller is more efficient than theolder centrifugal chiller under full and part-load conditions, which can mean significant savings giventhat most chillers operate 95 percent of the time or more under part-load conditions. Modular chillers

    use a refrigerant that is more environmentally friendly than most and usually consumes only one-fifthof the refrigerant that is consumed by conventional chillers. They are more environmentally sound inthe sense that they give you more control over how and when your building is cooled, therebyreducing any wasteful use of energy. Thanks to their built-in microprocessor controls, it is much easierfor you to match your cooling load and to cool a room when needed. These chillers are also super quiet(79 dB(A)), allowing you to put them where you want. They are reliable to the extent that the coolingprocess never needs to be interrupted, even if there is an equipment breakdown and they arecompatible with most building automation systems for remote on/off control. All these features mean

    much lower operating costs than you would ever find with conventional cooling systems.

    3. Low maintenance and repair costsare one more reason to go with a modular chilling solution.

    This cost, however, is not the same for every modular chiller design. Some designs absorb the costassociated with equipment failure, by giving you the option to purchase a backup unit in case theprimary chiller breaks down. Other designs, like the one by Tandem Chillers, make it possible toremove the defective piece of equipment, repair it and then reinstall it, all without interrupting the

    cooling process. Having this option saves on buying extra chillers for stand-by. In addition to this,modular chillers are generally designed so that most parts can be purchased at your local wholesalerand fixed by a qualified local HVAC professional.

  • 8/10/2019 Air Conditioning Systems Using Modular Chillers

    2/5

    Replacing Existing Air Conditioning Systems

    Replacing your air conditioning system with a modular chiller is not a decision you can make until youare confident that this solution will work for your own particular building. Older buildings, hi-riseapartments, office buildings, hospitals and casinos each present their own unique challenges. Eachbuilding has its own distinctive function and structure, which will have an impact on your decision.More often than not, the decision to replace is driven by long-term costs. Aside from lower installationand maintenance costs, a new modular chiller gives you the opportunity to better match current and

    future cooling demands. Older cooling systems were often sized for the original load of a facility.However, since installation, many facilities require a greater cooling load because of more people,

    technology and square footage. By better matching current loads with new units, you can get betterperformance and operating efficiencies. Regardless of what type of building you are dealing with, thereare three things to consider before you can decide if a modular chiller is for you.

    1. Determine Your Cooling LoadDetermine how many tons of cooling are required to meet the variable cooling loads created by thebuilding, such as climate, number of people traveling through the building, the type of equipment , etc.

    2. Estimate Accessibility

    Determine how difficult it will be to install a chiller in your building. In most cases the room where thechiller is going to be installed is accessed through a narrow staircase, hallway or by elevator. In manyinstances, buildings were constructed around the cooling system, making it virtually impossible toextract the old system and replace it with a new one. Physical site constraints often demand that theinstallation of a modular chiller unit must be done in stages where modules are delivered in sectionsand assembled on site.

    3. Calculate Your Cooling Load VariationDetermine whether or not there are activities in the building that will create an occupant load withinthe building which varies greatly throughout the day and the week. This results in a wider than usualrange of cooling loads and complex operating and technical requirements for the chiller plant which aremost efficiently met through the use of a modular chiller. Try, if you can, to calculate future coolingload ranges, given that there will probably be more people in your building, newer equipment, andexpansion. Whatever you decide, make sure that the cooling system you purchase has all the controlsneeded to handle these cooling variations.

    Health Facilities -hospitals, retirement homes, clinics.

    When it comes to upgrading existing air conditioning systems in a health facility such as a hospital,retirement home or clinic, there are several requirements that must be met. Given that most healthfacilities are largely underfunded, most buildings are older and still rely on air conditioning technologythat is no longer energy efficient. Since the facilities are usually in a business which deals with largenumbers of people with health related problems, the buildings are large, multi-storied facilitiescontaining a lot of equipment that generates heat. In most cases, the building was built around thecooling system in either a small mechanical room in the basement or in a small room near the top ofthe building.

    Replacing this system with a conventional chiller is going to be difficult without using heavy movingequipment, i.e., helicopters or cranes, and knocking down many walls to get the chiller into the

  • 8/10/2019 Air Conditioning Systems Using Modular Chillers

    3/5

    basement. Not only is this going to be expensive and time consuming, it also means a major disruptionto the daily operation of the facility and is very hard on the patients themselves. In cases like this, theonly solution is one that does not involve excessive reconstruction or any major disruption of thefacility's daily operation. Moreover, the cooling system must be relatively quiet and safe so as not todisturb the building occupants. The unit must be compact since space will be extremely limited and ithas to be able to tie into existing water piping.

    Historical Buildings - state capitol buildings, museums, churches.

    When you have an older building with no air conditioning or an obsolete system that can no longer dothe job, you are often talking about a building that was built before air conditioning was even invented.It is usually a building where corridors and doors are only designed only for human passage. Walls arethick, and often the main element of support, as in a brick-built house, making them hard to removeor tear down. The cooling system, if there is one, is in a very small room in the basement. Upgrading

    the cooling system or installing a new system in an older building is going to be overly expensive andtime consuming unless you can do the job without a ny renovations. The new system will have to besmall enough to fit in the equipment room and it will have to fit through small doorways and stairways.In some cases, the new system will have to sit beside the old system because the old system can't beextracted without removing walls and widening doorways.

    In an older building, there are obvious clues that a chiller is ready to be replaced: it has exceeded itsexpected service life,it is costing more to maintain the system and it is wasting energy. A new chiller ismore energy efficient, will eliminate the CFC problem, reduce maintenance costs and is more compact,allowing you to put 2,500 tons of cooling in the footprint of a 1,500-ton chiller. This gives more youmore capacity without sacrificing more space. This is an important consideration when space is anissue.

    Government and Commercial Buildings - courts, officebuildings, banks.

    In any government or commercial building, the biggest obstacle to replacing the cooling system will to

    be the impact on the daily operation of the building. With so much depending on the operation of agovernment or a business, any interruption in the daily activity of the building is to be avoided at allcosts. The second major problem is the fact that these buildings require cooling all year long even

    though these requirements can vary rapidly at any given moment. Extreme wide load variationsthroughout the year demand that you have more control over the cooling system than is possible.

    Cooling systems for government and commercial buildings are often located in basement mechanicalrooms and are accessed through a narrow staircase, hallway, or by elevator. Non-modular chillershave larger physical dimensions, requiring structural alterations to the foundation walls and theconstruction of an area well to allow for the delivery of the unit. Significant renovations within areassuch as a basement mechanical room, and storage areas, including the relocation of major electricaland mechanical equipment on site, would also be necessary to allow for the installation of a largerunit. The additional construction work would nearly double the chiller installation costs and potentiallydisrupt everyday operations.

    Entertainment Venues - casinos, restaurants, bars, halls, hotels, art galleries.

  • 8/10/2019 Air Conditioning Systems Using Modular Chillers

    4/5

    In buildings such as casinos, restaurants and hotels there are often cooling requirements that areunique to all entertainment venues. Entertainment venues are often places that hold many people oroften see an extremely large transfer of people. Since the amount of traffic can change quickly, thebuilding usually requires a rapidly changing cooling load that can change to suit each room in thebuilding. Because most entertainment venues are constantly growing, expandability is desirable andnecessary.

    Cooling systems for hotels and casinos are often located in basement mechanical rooms and are

    accessed through a narrow staircase, hallway or by elevator. Non-modular chillers have larger physicaldimensions, requiring structural alterations to the foundation walls and the construction of an area well

    to allow for the delivery of the unit. Significant renovations within areas such as a basementmechanical room, and storage areas, including the relocation of major electrical and mechanicalequipment on site would also be necessary to allow for the installation of a larger unit. The additionalconstruction work would nearly double the chiller installation costs and potentially disrupt operations.

    Education and Technical Institutions - universities,colleges, schools, labs, data centres.

    In most educational and technical facilities, the same problems are often encountered when it comesto upgrading the cooling system. The systems are usually located in the basement in a mechanicalroom that is small and awkward to access. These systems are often unreliable, inefficient and would

    cost too much to replace even if that were possible. In some cases, a single cooling source isresponsible for supplying air conditioning to multiple buildings. These institutions are unique in theirfunctions for several reasons. Being designed for education and experimentation, they have a largeneed for heat generating equipment such as computers and lasers, are often in need of expansion, andrequire a comfortable working environment for students, teachers, scientists, etc.

    These factors make selecting the right cooling solution a challenge. The daily activities of these

    institutions cannot be disrupted. The cooling system must be reliable, safe, quiet and environmentallysound, given the nature of the work that goes on in these types of buildings. The biggest obstacle is

    the matter of control. Control over the cooling, where and when it takes place, is more important thanin any other setting. Rigid standards must be in place to ensure that normal everyday functionscontinue to operate without any problems. It has to be possible to cool each room according to theneeds of its occupants and equipment. Since these buildings are in operation year round, thesecontrols have to be in place for the entire year and capable of handling a wide range of cooling needs.

    Industrial Processes - plastics, rubber, metal working, plating, die casting, printing, food,

    pharmaceutical, cosmetics, chemical and petrochemical.

    It is a common mistake in any typical industrial setting to install a cooling system that is eventually

    incapable of providing the required process cooling due to expansion. If you have an industrial processwhere expansion is inevitable but difficult to anticipate or calculate, a modular chilling systemis theperfect answer.

    Designed specifically for future expansion, with fully assembled external water piping our modularchillers are easy to install, remove and re-installfor service when required. When you expand yourprocess, a new module can be brought in and installed within a matter of hours with little downtime.

  • 8/10/2019 Air Conditioning Systems Using Modular Chillers

    5/5

    Our high efficiency - high EER (energy efficiency ratio) modular chiller system is designed so thatchiller units can be field-coupled to meet large tonnage requirements with an ongoing energysavingsthroughout the life of the chilling system. With a small footprint, these units occupy lessspace than a larger tonnage unit or units. Our system is specifically designed for future expansions byallowing chiller units to be added in stages to precisely match cooling load requirements.

    With our microprocessor controller in each chiller and a master control unit incorporating our exclusive"intelligent chiller control program", we can signal potential problems before they happen, saving

    costly down time, and stage compressors on system temperature, thereby accurately maintaining theleaving water temperature and saving energy by operating compressors only as they are required.

    Our control system has its own unique maintenance program operating in the background to managethe following functions: lead-lag compressors, equalize compressor run time, totalize compressor runtime for viewing, monitor phase loss and reversal, under and over voltage, and voltage imbalance,

    prevent compressor short cycling (minimum run time and off time) and stage compressor starts sothat one compressor at a time starts to ease inrush current.

    Tandem Chillers, 111 Esna Park Drive, Unit 7, Markham, Ontario, L3R 1H2

    Toll Free: 1.877.513.8310 ~ Email:[email protected]

    Equipment

    Water Cooled

    Air Cooled

    Condensing Units

    Condenserless

    Remote

    Free Cooling

    Fluid Coolers

    Pumps

    Strainers

    Applications:

    Computer Room

    Process

    Plastics

    Air Conditioning

    Ice Making

    Copyright 2014. Tandem Chillers. All rights reserved

    mailto:[email protected]:[email protected]:[email protected]://www.tandemchillers.com/watercooled.htmhttp://www.tandemchillers.com/aircooledchillers.htmhttp://www.tandemchillers.com/condensingunits.htmhttp://www.tandemchillers.com/condenserlesschillers.htmhttp://www.tandemchillers.com/remoteaircooled.htmhttp://www.tandemchillers.com/freecoolingunits.htmhttp://www.tandemchillers.com/aircooleddryfluidcoolers.htmhttp://www.tandemchillers.com/pumppackages.htmhttp://www.tandemchillers.com/filtration.htmhttp://www.tandemchillers.com/computerroom.htmhttp://www.tandemchillers.com/processcooling.htmhttp://www.tandemchillers.com/plastics.htmhttp://www.tandemchillers.com/airconditioning.htmhttp://www.tandemchillers.com/icemakingchillers.htmhttp://www.tandemchillers.com/icemakingchillers.htmhttp://www.tandemchillers.com/airconditioning.htmhttp://www.tandemchillers.com/plastics.htmhttp://www.tandemchillers.com/processcooling.htmhttp://www.tandemchillers.com/computerroom.htmhttp://www.tandemchillers.com/filtration.htmhttp://www.tandemchillers.com/pumppackages.htmhttp://www.tandemchillers.com/aircooleddryfluidcoolers.htmhttp://www.tandemchillers.com/freecoolingunits.htmhttp://www.tandemchillers.com/remoteaircooled.htmhttp://www.tandemchillers.com/condenserlesschillers.htmhttp://www.tandemchillers.com/condensingunits.htmhttp://www.tandemchillers.com/aircooledchillers.htmhttp://www.tandemchillers.com/watercooled.htmmailto:[email protected]