All rights reserved 12/16 SS c 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor. Cautions on product corrosion Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the user's manual carefully before using this product. The user's manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer. Specifications, designs and other content appearing in this brochure are current as of December 2016 but subject to change without notice. PCSVN1602A Air Conditioning System Heat pump 50Hz

Transcript of Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan...

Page 1: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

All rights reserved 12/16 SSc

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install the outdoor unit close to the sea shore, contact your local distributor.

Cautions on product corrosion

Warning Ask a qualified installer or contractor to install this product. Do not try to install the product by yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.Read the user's manual carefully before using this product. The user's manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

If you have any enquiries, please contact your local importer, distributor and/or retailer.

Specifications, designs and other content appearing in this brochure are current as of December 2016 but subject to change without notice.

PCSVN1602A

Air Conditioning SystemHeat pump 50Hz

Page 2: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

Page 3

Page 7

Page 9

Page 11

Page 13

Page 13

1 2

P r o d u c t L i n e u p

DUCT CONNECTIONMIDDLE STATIC PRESSURE TYPE

CEILING SUSPENDED TYPE

71 100 125 140

RQ71MV1 RQ71MY1FCQ71KAVEA FCQ100KAVEA

RQ125MY1FCQ125KAVEA

RQ140MY1FCQ140KAVEA

FHQ71DAVMA FHQ100DAVMARQ125MY1

FHQ125DAVMARQ140MY1

FHQ140DAVMA

FBQ71EVE FBQ100EVERQ125MY1FBQ125EVE

RQ140MY1FBQ140EVE

FVQ71CVEB FVQ100CVEBRQ125MY1

FVQ125CVEBRQ140MY1

FVQ140CVEB

Outdoor unitIndoor unit

CEILING MOUNTED CASSETTE TYPE

Round Flow

Series

Outdoor unitIndoor unit

Outdoor unitIndoor unit

FLOOR STANDING TYPE

3Phase 50Hz380-415V

Outdoor unit

Outdoor unit

Indoor unit

Heat pump

RQ100MV1 RQ100MY1

RQ71MY1 RQ100MY1

RQ71MV1 RQ71MY1 RQ100MV1 RQ100MY1

RQ71MV1

RQ71MY1 RQ125MY1 RQ140MY1RQ100MY1

RQ71MY1 RQ100MV1 RQ100MY1

CEILING MOUNTED CASSETTE TYPE

CEILING SUSPENDED TYPE

DUCT CONNECTIONMIDDLE STATIC PRESSURE TYPE

FLOOR STANDING TYPE

Daikin meets your needs with the line up of various types of indoor units and power supplies

OUTDOOR UNIT1 Phase 50Hz

220-230V

Outdoor unit RQ71MV1 RQ100MV1

Page 3: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

A built-in antibacterial treatment that uses silver ion in the drain pan prevents the growth of slime, bacteria, and mould that cause smells and clogging.

Condensation does not easily form on and dirt does not cling to non-flocking flaps. It is easy to clean.

Non-flocking flapsSilver ion anti-bacterial drain pan

Prevents mould and microorganisms growing out of the dust and moisture that adheres to the filters.

Filter has anti-mould and antibacterial treatment

Comfort enhanced by Round Flow!

Greater comfort

Avoids uneven temperature and discomfort caused by drafts

With uniform temperature distribution

360° air�ow

360° airflow can maintain comfort even if air discharge speed is lower.

Velocity decreases by 25% when set temperature is raised 1℃ to 1.5℃.

Room remains comfortable even when set temperature is raised 1℃.

Enhanced Comfort

Air movement is gentle with Round Flow

Airflow distribution

creates uniform comfort throughout

the space.

• Condition after exposure to the smoke of 600 cigarettes in 1 m3 enclosed space.

Treated surface

Untreated surface

Grimy surface

Resists soiling

External panels are treated with a coating that repels dirt

To prevent dirt sticking to the external panels, they have been coated with a surface treatment

Because air flows out from corner outlets, comfort spreads more widely

Grime prevention and antibacterial coating: Make cleaning easier

Adapts easily to the installation space

Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet.

3-way flow L-shaped 2-way flow

Opposite 2-way flow

(E.g., installed in a corner)

(E.g., installed in a long room)

(E.g., installed near a wall)

(E.g., installed in middle of ceiling)

4-way flow also possible.

All-round flow

Typical flow patterns There are a total of 23 flow patterns.

Operation sound increases when using 2-way or 3-way flow.

Accessory required for indoor unit.Option

CEILING MOUNTED CASSETTE TYPE

FCQ71/100/125/140KA

Round Flow

BRC1E62

Navigation Remote Controller(Wired Remote Controller)

A signal receiver must be added to the indoor unit.

BRC7F634FHeat pump

Wireless remote controller is supplied in a set with a signal receiver.

Wireless LCD remote controller

Signal receiver unit (Installed type)

Note: Remote controller cable is not included and must be procured locally.

Note: Remote controller cable is not included and must be procured locally.

Wired LCD remote controller

BRC1C61

3 4

Cassette air conditioner with 360° uniform airflow sets the standardCassette air conditioner with 360° uniform airflow sets the standard

Page 4: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

Easier to maintain

With Ultra long-life filters (option), maintenance is not required in normal shops or offices for up to four years

Options required for specific operating environments

Filter chamber (Can be used with ultra long-life filter)

High-efficiency filter

Filter chamber (Can be used with high-efficiency filter)

Ultra long-life filter

High-efficiency filter unitAvailable in two types: 65% and 90% colorimetry.

Please use if you think the temperature and humidity inside the ceiling exceeds 30°C and RH 80%, respectively.

Insulation kit for high humidity

Using this kit, a duct can be connected to take outdoor air in.There are two chamber types that have intake in two places: with T-duct joint and without T-duct joint.

Fresh air intake kit

Even in dusty environments where the air conditioning is on most of the time, the ultra long-life filter only has to be cleaned once a year.

Ultra long-life filter unit

Panel spacerUse when only minimal space is available between drop ceilings and ceiling slabs.

Sealing material of air discharge outletSealing material block air discharge openings not used in 2-way or 3-way blow.

Outside

Note: Some ceiling constructions may hinder installation. Contact your Daikin Dealer before installing your unit.

40mm

Panel spacer

Branch duct (direct-connection round duct)A round duct can be attached without the need for a chamber.A flanged port for direct connection of a round duct is provided. An existing branch duct chamber can also be fitted (square slit hole).

Dusty area: annual filter change

Ordinary store or office: filter change every 4 years

*For dust concentration of 0.3 mg/m3 (Requires separately sold Air purifier.) 1 year (Approx. 5,000 hr) 15 hr/day x 28 day/month x 12 month/year

*For dust concentration of 0.15 mg/m3

4 years (Approx. 10,000 hr) 8 hr/day x 25 day/month x 12 month/years x 4 years

1 Use of options will increase operating sound.2 Connecting ducts, fan, insect nets, fire dampers, air filters, and other parts

should, as required, be procured locally. 3 When a local-procured fan is used, an interlock with air conditioner is

necessary.Optional PCB(KRP1C63)is required for interlocking.4 It is recommended that the volume of outdoor air introduced through the kit is

limited to 10% of the maximum airflow rate of the indoor unit. Introducing higher quantities will increase the operating sound and may also influence temperature sending.

Note:

The units can be installed in the following different ways.

Intake duct(procured locally)

Direct installation type

Chamber type (with T-duct joint)

KDDP55X160A

KDDP55B160K

Chamber type (without T-duct joint) Note 3.4

Note 3.4

KDDP55B160

Intake duct(procured locally)(duct length: 4 m max.)Connection

chamber

Suction chamber

Connection chamber

Suction chamberTop panel insulation(1)

Top panel insulation(2)Top panel insulation(3)Insulation for decoration panelSide panel insulation Suspension bracket insulation

Flexible duct(procured locally)

T-duct joint(procured locally)

Intake duct(procured locally)(duct length: 4 m max.)

Flexible duct

T-duct joint

Duct flange (with insulation material)

Note 1.2

The condition of the drain pan anddrain water can be checked byremoving the drain plug andsuction grille Drain plug

Just open the

suction grille!

5 6

CEILING MOUNTED CASSETTE TYPE Round Flow

Quick and easy to installJust 256 mm high. Installable in tight ceiling spaces (71KA)

Drain pump is equipped as standard accessory with 850 mm lift

Unified square panels Compact body and quiet operationPanel size is the same for all models, FCQ71-140KA.It is easy to maintain a neat appearance when multiple units are installed in the same room.

Optimal comfort and convenience assured by 2 air discharge modes

Control of airflow rate has been improved from 2-step to 3-step.

dB(A)Sound pressure level

Same for all models

950 mm 950 mm

256 mm *1 266 mm *2

*1 298 mm high with 100–140KA*2 308 mm high with 100–140KA

All models can be installed without using lifter because of the light weight

Transparent drain socket

Each corner of the unit has an Adjuster Pocket that lets you easily adjust the unit's suspended height.

Note: If the wireless remote controller is installed, a signal receiver unit is housed in one of the adjuster pockets.

Since the orientation of the suction grille can be adjusted after installing, the direction of the suction grille lines can be unified when multiple units are installed.

DIII-NET communication standardConnection to a centralised control system is available without option.

Easy height adjustment

Installed in any direction

Switchable fan speed: High/Middle/Low

175 mm

850 mm

4-wayflow

3-wayflow

2-wayflow

4-wayflow

3-wayflow

2-wayflow

3.1 m3.4 m4.0 m

All round flow

2.7 m3.0 m3.5 m

3.0 m3.3 m3.5 m

3.5 m3.8 m-

3.4 m3.9 m4.5 m

All round flow

3.2 m3.6 m4.2 m

3.6 m4.0 m4.2 m

4.2 m4.2 m-

StandardHigh ceiling High ceiling

Criteria for ceiling height and number of air discharge outlets

Note: Factory settings are for standard ceiling height and all-round flow. High ceiling settings (1) and (2) are set with the remote controller by field setting.

(Ceiling height is reference value)

71KA 100–140KA

Ceiling height

Number of air discharge outlets used

Indoor unit

125KA140KA

100KA71KA

High

4444

4335

Middle

3940

37.531.5

Low

3436

3228

Two selectable temperature-sensors See page 19

Note: 1Air direction is set to the standard position when the unit is shipped from the factory. The position can be changed from the remote controller.2Closing of the corner discharge outlets is recommended.

Air direction

Auto air direction control

Settable to 5 different levels between 15° and 60°

Settable to 5 different levels between 25° and 60°

Auto-swing between15° and 60°

Auto-swing between25° and 60°

Recommended for shops with light coloured ceilings that

must be kept spotless.Standard setting to

prevent draft.

Standard setting1 Setting to prevent soiling of ceiling2 (field setting)

At heating startup and thermo OFF, air discharge is automatically set to a near horizontal 25˚ or 30˚ to prevent direct exposure to cool air drafts.

Desired situation

Auto-swing

5-levelsair directionsetting

Draft prevention(In heating mode)

The air direction is set automatically to the memorised position of the previous air direction.

Even in spaces with high ceilings, a comfortable airflow is carried down to the floor level.

Suitable for high ceilings

When all round flow is selected, ceilings up to 4.2 m in height can be accommodated. (100-140KA)

Setting SettingStandard

4.2 m3.6

m3.2m

Page 5: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

Oil resistant grille

Note: Intended for use in salons, dining rooms, and ordinary sales floors, this specification is not suitable for kitchens or other harsh environments.

Oil-resistant plastic is used for the air suction grille. This satisfies durability in restaurants and other similar environments.

Comfortable

Flap neatly closes when not in use.

The latest stylish model

Quiet operationdB(A)

Indoor unit HighSound pressure level

Low71DA

100DA125DA140DA

Middle

The technology of the DC fan motor, wide sirocco fan, and large heat exchanger combine for greater airflow and quiet operation

Sophisticated design

White colour

Auto swing (up and down) and louvers (left and right by hand) bring comfort to the room

Switchable fan speed: High/Middle/Low

-

Suitable for high ceilings

StandardHigh ceiling

71DA 100DA 125/140DA2.7m or less 3.8m or less 4.3m or less2.7m~3.5m 3.8m~4.3m

Note: Factory settings is “standard”. “High ceiling” are set with remote controller by field setting.

3.5m

71DA

4.3m

100-140DA

Non-flocking flap

Easy maintenance

Easy-clean, flat surfacesIt is easy to wipe dirt off the flat side and lower surfaces of the unit.

Condensation does not easily form on and dirt does not cling to non-flocking flap. It is easy to clean.

Non-flocking flap

Drain pump kit (option) includes a silver ion antibacterial agent that assists in preventing the growth of slime, bacteria, and mould that cause smells and clogging

Drain pump kit (built inside the unit)

600 mm

Flexible installation

*Water used in the test-run can be drained from the air discharge opening rather than from the side as was formerly the case.

The unit fits more snugly into tight spaces.

Drain pump kit (option) can be easily incorporatedDrain pipe connection can be done inside the unit. Refrigerant and drain pipe outlets are at the same opening.

All wiring and internal servicing can be done from under the unit

Installation flexibility for freedom of design

Easier piping work for rear side by removable frame

DIII-NET communication standardConnection to a centralised control system is available without option.

30 mm or more

30 mm or more

Programme "Dry" See page 19

Two selectable temperature-sensorsSee page 19

Louver manually adjusts for straight or wide angle airflow

38 3442 3444 37

363841

46 3842

Option

BRC1E62Note: Remote controller cable is not

included and must be procured locally.

A signal receiver must be added to the indoor unit. Wireless LCD remote controller

CEILING SUSPENDED TYPE

Wireless remote controller is supplied in a set with a signal receiver.

Signal receiver unit (Installed type)

Comfortable airflow travels throughout the roomComfortable airflow travels throughout the room

FHQ71/100/125/140DA

7 8

Accessory required for indoor unit.Option

Note: Remote controller cable is not included and must be procured locally.

Wired LCD remote controller

BRC1C61

Navigation Remote Controller(Wired Remote Controller)

Heat pump BRC7GA53

Page 6: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

(“Auto” is applicable when BRC1E62 is used.)

ComfortSwitchable fan speed:High/Middle/Low and Auto

A built-in antibacterial treatment that uses silver ion in the drain pan prevents the growth of slime, bacteria, and mould that cause smells and clogging.

CleanSilver ion anti-bacterial drain pan

Easy maintenancePosition of drain pan inspection opening has been modified for easier inspection work

High efficiencyDC fan motor and DC drain pump are utilised to improve energy efficiency

Higher lift is realized by utilising built-in DC drain pump with standard accessory

850mm

Middle & High static pressure type(FBQ-D series)

700mm

Using a DC fan motor, the external static pressure can be controlled to within a range of 50 Pa to 150 Pa

Comfort airflow is achieved in accordance with conditions such as duct length.

Adjustable external static pressure

50 Pa 150 PaSet to high static pressure for

advanced needs such as when using dampers and long ducts.

Set to low static pressure when ducts

are short.

Easy maintenance because the drain pan can be removed

Drain pan maintenance check windowThis makes it possible to inspect for drain pan dirt and to confirm drainage during installation without the use of tools.

Inspection opening for drain pan

Drain pan maintenance check window

Airflow rate auto adjustment functionControls the airflow rate using a remote controller during test run.It is automatically adjusted to approximately ±10% of the rated H tap airflow.

DIII-NET communication standardEasier communication and connection with the centralised control system.

Interlock control As an energy saving feature, the room air conditioning unit can be interlocked with the hotel key card system.

Using a 3rd-party building management system, air conditioning and lighting can be interlocked.* Field setting with remote controller

Design and installation flexibility

With a height of only 245 mm, installation is possible even in buildings with narrow ceiling spaces

One of the industry’s most compact bodies in the mid-static pressure range.

245100/125/140E

1,000 1,400800

HeightIndoor unit

WidthDepth

71E(mm)

(mm)

(mm)

245mm

Interlock

Bottom suction is availableWiring and servicing can be done from the underside of the unit (an option part required).

Control box cover

Control box faces outward. Control box faces inward.

Air suction flange

Control box cover

Air suction flange

Bottom plate

Sield plate for side plate(option)

Bottomplate

Switch bottom plate with air suction flange.Make the control box face inward.

Air suction

joistunit

ceiling

Rear suction Bottom suction

BRC1E62

Navigation Remote Controller(Wired Remote Controller)

Note: Remote controller cable is not included and must be procured locally.

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

FBQ71/100/125/140E

A signal receiver must be added to the indoor unit.

BRC4C65Heat pump

Wireless remote controller is supplied in a set with a signal receiver.

Wireless LCD remote controller

Signal receiver unit (Separate type)

Note: Remote controller cable is not included and must be procured locally.

Wired LCD remote controller

BRC1C61

9 10

Thinner design allows greater installation flexibilityThinner design allows greater installation flexibility

Accessory required for indoor unit.Option

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)

Ventilation grille

Door-installedventilation grille

Ventilation grille

Wall-installedventilation grille

Under-door cutout

Under-door cutoutWhen air conditioning two rooms simultaneously, the air discharged into each room must be circulated back to the air conditioner. To achieve this, a ventilation duct should be installed for each room or one of the indicated ventilation grilles should be installed on the partitioning wall or under the door between the rooms.

Ventilates air through the partitioning wall. (See right)

Partitioning wall

Note: The under-door cutout method should be used only when there is a small volume of airflow.

Page 7: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

Quiet operation

Quick and easy installation and maintenance

Lightweight indoor unitEnables smooth transport and installation of the indoor unit.

The grill will not open even upon impact.

Energy savingDC fan motor improves efficiency

Employs a safety lock function of suction grille

100C 125C 140CHigh

Indoor unitSound pressure level

71C

50 51 5343Middle 47 48 5141Low 44 46 4838

dB(A)

39 47

100C 125C 140C

Weight

Indoor unit 71C(kg)

Comfortable fan speed control

To carry airflow to the far side of the room, airflow rate can be increased 5% or 10% depending on the installation condition or customer's request. (Field setting by remote controller.)

High fan speed mode

Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature.

Programme "Dry"

(applicable for FVQ71/100)

Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature.

Auto airflow rate is selectable

Example applications

When cooling

Turning louvers and upward and leaving and horizontal will reduce uneven room temperature.

New comfortable airflow control1) Left and right directions

2) Up and down directions Independent up-and-down airflow directions facilitate even room temperature and help save energy.

New unit

(by remote controller)

(by hand)

Freely select both up and down airflow direction with 8-louver (horizontal blade) setting.

Upper louver (1)Upper interlocking louvers (4)Lower interlocking louvers (2)Lower louver (1)

Each set of louvers to can be independently adjusted. (Manual adjustment)

Auto swing direction is selectable from 3 patterns to suit the layout of the room.

Pattern 1 Swing wide across the front

When installed in the center of a wall. When installed in the corner of a room.

Pattern 2 Swing across left side Pattern 3 Swing across right side

Switchable fan speed: High/Middle/Low and Auto("Auto" is applicable when BRC1E62 is used.)

(Applicable when BRC1E62 is used.)

* For dust concentration of 0.15 mg/m3

Long-life filter (standard) requires no maintenance for about 1 year*The filter is washable and reused after 1 year.

-Two time settings (2500 hrs and 1250 hrs) are available to match the installation environment. Maintenance time warning is displayed on the remote controller (filter sign).

-The periodical cleaning time for the filter can be shortened depending on the usage environment.

DIII-NET communication standardConnection to a centralised control system is available without option.

Note: Remote controller cable is not included and must be procured locally.

Wired LCD remote controller

BRC1C61

FLOOR STANDING TYPE

New airflow control for more comfortNew airflow control for more comfort

11 12

Accessory required for indoor unit.Option

BRC1E62 can be

incorporated into the

indoor unit.

(Wired Remote Controller)

Navigation Remote Controller

Note: Remote controller cable is not included and must be procured locally.

BRC1E62

FVQ71/100/125/140C

Page 8: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

OUTDOOR UNIT

Outdoor unit

Easy installation and maintenance

Durability

Construction

Non-treated fin

Anti corrosion treated fin

Aluminium

AluminiumCorrosion resistantresin

Hydrophilic treatment

As the bottom frame is subject to corrosion, a corrosion-proof galvarium steel plate is adopted to enhance the durability

Heat exchange fins are provided with anti-corrosion treatment

Allowed refrigerant piping length and level difference

Note : 1Additional refrigerant charging is required if the refrigerant pipe is longer than the length.

Max. length

Max. leveldifference

Pre charged1

RQ71-140M

30 m

50 m(Equivalent length 70m)

30 m

Separation available

If the refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging.

Pre charged for up to 30 metres

Long piping length

The outer panel for the piping connection part of the front, right side and backside can be removed and is easier for post-installation piping work.

4-direction piping offers greate rlayout freedom

Removable part of bottom frame makes the piping work easier

A pump-down switch is provided to make it easier to collect refrigerant if the unit is to be moved or layout modified.

Facilitates pump down (Refrigerant recovery function)

*Pump-down function is available for pre-charged refrigerant amount.

RQ100MV1RQ100MY1

RQ71MV1RQ71MY1

RQ125MY1RQ140MY1

13 14

Whatever your space, give it the comfort it deserves

Easy centralised installation with the module oriented designDepth of 71-140M are standardised as 320 mm. Horizontal continuous mounting is available.

71M

900 mm

320 mm

Suction

Discharge

100M

900 mm

125M

900 mm

140M

900 mm

-20-10

0102030

40

50Wide operation range

46˚CDB

Cooling

-5˚CDB

Outdoor temp(˚CWB)Outdoor temp(˚CDB)

Heating-10˚C

WB

15˚CWB

Cooling is efficient even in winter when indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers.

Operation range

Suited for year-round cooling applications

Comparison of outdoor unitsRY140LUY1 RQ140MY1

Height 1,345 mm 1170 mmWeight 112 kg 101 kg

Reduced installation work thanks to light, compact outdoor unit.

Compact and lightweight

RQ140MY1RY140LUY1

Reduced by175 mm

Reduced by11 kg

1170mm

Page 9: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

Enables temperature sensing closer to target area for improved comfort. (When using remote control from another room, temperature-sensor in indoor unit's air inlet must be selected.)

Facilitates maintenance and repairAll initial settings can be set from the remote controller. After interior construction is complete, ceiling mounted cassette type can be remotely set without having to use stepladder access for manual setting.Setting contents: High ceiling use, air direction, filter type, address for centralised control (group control address is set automatically).

Remote controller is equipped with model name and failure display functions. This facilitates service in the unlikely event of a malfunction.

SkyAir shares common control with Heat Reclaim Ventilator and the other Daikin air-conditioning units, thus simplifying interlocking operations.

Easily adaptable to large-scale, high-function, centralised remote control systems.Installing and connecting control wiring between SkyAir and other Daikin air-conditioning equipment is easy.

LCD panel shows operating status in letters, numbers, and motion.Airflow / swing display Displays auto-swing operating status and setting position of air discharge angle.

Preset temperature / operation mode display Displays preset room temperature and operating status (fan, dry, cool).

Programming time display Operation start and stop time can be set for individual timers up to 72 hours. The LCD also shows when it is time to clean the filter, when changeover is under centralised control, and ventilation/cleaning.

Self-diagnosis function Monitors operating status within the system covering 40 items, and displays a message to indicate as soon as a malfunction occurs.

CEILING MOUNTED CASSETTE TYPECEILING SUSPENDED TYPEDUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

BRC7F634FHeat pump

BRC7GA53BRC4C65

Wired remote controller has built-in temperature-sensor (Applies to wired remote controllers (BRC1C61/1E62))

(Model name display function applies to BRC1E62 only.)

Signal receiver unit (For ceiling mounted cassette type)

Wireless remote controller for each indoor unit type

Wireless LCD remote controller

Note: The signal receiver unit shown in the photograph is for mounting inside the decoration panel of the ceiling mounted cassette type.

Wireless remote controller

BRC7F634F

The wireless remote controller is supplied in a set with a signal receiver.Signal receiver unit is contained inside decoration panel or indoor unit.Shape of signal receiver unit differs according to the indoor unit.

The rubber switch and the oil-resistant plastic casing are adopted for durability.Only 17 mm thick. Can be installed either recessed or exposed.

Easy to read because of large LCD screen.Wired LCD remote controller

BRC1C61

REMOTE CONTROLLER Optional accessory

15 16

Easy-to-read LCD remote controller allows various system control configurations and can control multiple indoor units. Remote controller options are shown on the page introducing each indoor unit model.

Navigation Remote Controller(Wired LCD Remote Controller)

- 5 actions per day can be scheduled for each day of the week.- The holiday function will disable schedule timer for the days that have been set as holiday.- 3 independent schedules can be set. (e.g. summer, winter, mid-season)

Display is available in 11 languages.

ConvenienceWeekly schedule Multilingual display

(English, German, French, Spanish, Italian, Portuguese, Greek, Dutch, Russian, Turkish, and Polish).NEW

Clear DisplayDot matrix display Backlight

displayA combination of fine dots enables various icons.Large text display is easy to see.

This simple, modern designed remote controller with fresh white colour matches your interior design. Operation is much easier and smoother, just follow the indications on the navigation remote controller.

Energy savingNEW

- Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts.- Period can be preset from 30 to 180 minutes in10-minute increments.

Off timer (programmed)

Setpoint range setNEW Setpoint auto reset

Restaurant exampleRestaurant opened

Temperature is set to 27ºC

27°C

- Saves energy by limiting the min. and max. set temperature.

- Avoids excessive heating or cooling.

- This function is convenient if the remote controller is installed where anyone can change the settings.

- Even if the set temperature is changed, after a preset period new set temperature returns to preset value.

- Period selectable from 30, 60, 90, or 120 min.

Full tables at lunchtimeThen is lowered to 24ºC for crowded room

24°C

After 30 minutes*Automatically returns to preset temperature (27ºC)

*Preset-return time can be set at 30, 60, 90, or 120 min

Returns to

27°Cautomatically

BRC1E62

Page 10: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

Central remote controllerEasily adaptable to large-scale, high-function, centralised remote control system.

Centralised control, with a setting as simple as it is with a standardremote controller, of up to 64 groups (1,024 indoor units) is possible.

DCS302CA61 (Option)

With its high functionality, the full colour “all-in-one” graphic controller facilitates management of SkyAir System in a variety of ways.

DCS601C51 (Option)

Unified on/off controller

Centralised control of on/off by group or all at once for up to 256 indoor units.

DCS301BA61 (Option)

Schedule timer

Unified control of weekly schedule for up to 1,024 indoor units.

DST301BA61 (Option)

Schedule timer sets on/off time in 1 minute units to be executed twice a day for a week at a time.

System variation to control multiple indoor units

Control by 1remote controller

Control pattern Wired remote controller Wireless remote controller

Control by 2remote controllers

Group control

Control by external command

Centralised remotecontrol

Interlock controlwith Heat Reclaim

Ventilator

(Basic system)

Link by remote controller group control.

Zone link control by centralised control.

For control from 2 locations such as in room and control room, exits, etc.

For simultaneous control of up to 16 indoor units.

Centralised control of up to 64 indoor groups from remote locationup to 1 km away.

Signal receiver unit installed on indoor unit

Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking. Can also be operated independently by remote controller.

Central remote controller (option)

Heat Reclaim Ventilator

Can be operated simultaneously or independently by remote controller (set by ventilation mode)

Heat Reclaim Ventilator

Non-polar, double-core (max. wiring length 500 m)

Connects 2 wired remote controllers (See note 1)

Automatic address setting function Automatic address setting functionSignal receiver unit installed on 1 indoor unit

Optional wiring adaptor for electrical appendices is necessary

Can be operated simultaneously by remote controller (set by ventilation mode)

Heat Reclaim Ventilator

Heat Reclaim Ventilator for indoor units within a zone are operated by interlocking

Central remote controller (option)

Heat Reclaim Ventilator

Operation and monitoring is carried out using the contact signal from the operation control box in the monitoring room. Optional wiring adaptor for

electrical appendices is necessary

Note:1BRC1E62 can connect to BRC1E62 only. 2It is not possible to use two wireless remote controllers. 3BRC1E62 cannot connect to wireless remote controller.

Central remote controller (option) Central remote controller (option)

Not possible (See note 2, 3)

(Command from outside) (Command from outside)

FunctionsoverviewFunctionsoverview

FUNCTIONS

Work & servicing

REMOTE CONTROLLER Optional accessory

17 18

*1 : Applicable when BRC1E62 is used*2 : Applicable when wired remote controller is used*3 : Applicable when BRC1C61 is used*4: For outdoor units

*5 : Applicable for FVQ71-100*6: Installable on max. 3.5 m(71) and 4.3 m (100-140) high ceiling*7: Option

Note:

RQ71-140MY1 RQ71-140MY1 RQ71-140MY1

Indoor unit

Outdoor unit

Comfort

Cleanliness

Remote Controller

Control features

Options

Others

CEILING SUSPENDED TYPECEILING MOUNTED CASSETTE TYPERound Flow

Auto swing Swing pattern selection

Setpoint auto reset *1Setpoint range set *1Weekly schedule timer *1Off timer (programmed) *1On/Off timer *3

Anti-bacterial air filter

Drain pump mechanism

Pre-charged for up to 30 m *4

Filter signLong-life filter

Ceiling soiling prevention

Auto-restart

Control by 2 remote controllersGroup control by 1 remote controllerExternal command controlCentral remote control Interlock control with Heat Reclaim VentilatorDIII-NET communication standard

High-efficiency filter

Ultra long-life filterFresh air intake kit

Anti corrosion treated heat exchangers *4

Draft prevention function (heating)Independent up-and-down airflow

Auto-cooling/heating change-over

Emergency operationSelf-diagnosis function

RQ71-140MY1RQ71/100MV1 RQ71/100MV1RQ71/100MV1

FLOOR STANDING TYPEDUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

FCQ71-140KAVEA FHQ71-140DAVMA FBQ71-140EVE FVQ71-140CVEB

DC fan mortor (Indoor unit)Switchable fan speed

Programme “Dry”High ceiling applicationTwo selectable temperature-sensors *2

Auto airflow rate *1High fan speed mode

Hot startYear-round cooling applicable

Silver ion anti-bacterial drain pan

Heat pump

3step 3step 3step 3step

*7

*7

*7

*7 *7 *7 *7

*6

*5

Page 11: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

Even if there is a malfunction elsewhere in the system, the fan or compressor can still be operated. (depending on the malfunction)

Emergency operation

You can turn up to 16 indoor units on/off with a single remote controller. (When using connected indoor units, the settings must all be the same and on/off will be simultaneous.)

Group control by 1 remote controller

Optional central remote controller enables centralised control of up to 1024 indoor units (64 groups) from up to 1 km away.

Central remote control

The operating parameters of indoor and outdoor units, and sensor data at critical locations throughout the system, are constantly monitored using a microcomputer. To facilitate quick response in the event of a malfunction, a message appears on the LCD of the remote controller and an LED on the unit illuminates.

Self-diagnosis function

Two types are available: 65% and 90% colorimetry.

High-efficiency filterYou can provide air-conditioning with fresh air from outside. Convenient for places where a ventilation fan cannot be installed.

Fresh-air intake kit

Work and Servicing

Control features

Options

Steeper gradient realises more efficient condensate drainage. High-lift is especially useful for long lengths of drain piping.

Maintenance is not required for one year*.The filter is washable and can be reused.

If refrigerant piping length does not exceed 30 m, there is no need for on-site gas charging.

The filter sign warns you when it is time to clean the filter. *When using a wired remote controller the sign is displayed in the LCD. When using a wireless remote controller the filter sign lamp illuminates on the signal receiver unit.

Drain pump mechanism

Long-life filter

Pre charged for up to 30 m

Filter sign

Daikin's innovative air discharge mechanism keeps airflow away from the ceiling. Ceiling cleaning is less frequently required.

Ceiling soiling prevention

Ultra long-life filter

If there is a power outage while the equipment is operating, operations will restart in the same mode as before the power cut when electricity is restored.

Auto-restart

Detects difference in preset temperature and actual room temperature and automatically switches to cooling or heatingaccordingly.

Auto-cooling / heating change-over

Using 2 remote controllers you can operate the equipment locally or from a remote location.Note: When a wireless remote controller is used, remote control by two remote controllers is not possible.

Control by 2 remote controllers

Requires no maintenance for about 4 years* (10,000h) in stores and offices.*For dust concentration of 0.15 mg/m3

Operation and monitoring is carried out using the contact signal from the operation control box in the building monitoring room.

External command control

*An option is required.

Others

Standardly equipped interface enables connection to centralised control system without need of an adaptor.

DIII-NET communication standard

To achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, Anti corrosion treated fin for heat exchangers (with special coating) are used for the heat exchanger of the outdoor unit. In high corrosive areas, regular maintenance needs to be carried out.

Anti corrosion treated heat exchangers

*For dust concentration of 0.15 mg/m3

Enables interlocking control with external equipment such as Heat Reclaim Ventilator.

Interlock control with Heat Reclaim Ventilator

19 20

Abundance of functions that provide comfortable air-conditioning in stores and offices.

Note: Some features only available on selected models. See overview pages for full list of features applicable to each unit.

Note:When units are installed on high ceilings, depending on the model, various restrictions concerning maximum height, air discharge direction, and choice of options may apply.

Delivers air-conditioning comfort all the way down to the floor in air-conditioning zones with high ceilings.

High-ceiling application

High setting provides maximum reach while low setting minimises drafts.

Switchable fan speed

To prevent cold air drafts, automatically adjusts airflow to near horizontal position when heating initially starts or when the thermo off.

Draft prevention function (heating)

Cold air flow is avoided when heating operation starts or whenswitching to heat after defrosting.

Hot start

Airflow rate is automatically controlled in accordance with the difference between room temperature and set temperature.

Auto airflow rate

Dehumidification is microprocessor controlled to prevent abrupt and uncomfortable changes in air temperature. Useful for reducing uncomfortable humidity without uncomfortable cooling of the room.

Programme "Dry"

Comfort

Delivers comfortable air-conditioning to all areas, near to and far from the air-conditioner.

Auto-swingThe air flow direction can be fixed at your desired angle by the remote controller.

Note: Wireless remote controllers have no temperature-sensor.

Use the temperature-sensor in the indoor unit when controlling air conditioning from another room.

Two selectable temperature-sensorsTemperature-sensors are included in the indoor unit and optional wired remote controller. Temperature sensing closer to target area is possible to further increase the comfort level.

Sets and saves setting for an increment of time that automatically turns off air conditioner after a preset period of time for each time operation starts.

Off timer (programmed)Remote Controller

Operation starts when the preset time of the ON timer elapses and stops when the preset time of the OFF timer elapses.

On/Off timer

Up to five operation ON/OFF settings can be programmed per day for each day of the week. Not only can the time be set for the operation ON setting, but also the temperature.

Weekly schedule timer

Even if the set temperature is changed, after a preset periodnew set temperature returns to preset value.

Setpoint auto reset

Saves energy by limiting the minimum and maximum set temperatures. Avoids excessive heating and cooling.

Setpoint range set

You can increase fan speed approximately 10% higher than the "high" setting.

High fan speed mode

DC fan motor improves efficiency.

DC fan motor (indoor unit)

Independently adjust (manually) the eight horizontal blade louvers in both up and down directions to achieve an airflow that reduces uneven room temperature.

Independent up-and-down airflow

Efficient cooling even in winter when the indoor temperatures are higher than those outside, such as in underground public spaces or offices with many computers.

Year-round cooling applicable

Cleanliness

A built-in antibacterial treatment that uses silver ion in the drain pan prevents the growth of slime, bacteria, and mould that cause smells and clogging.

Silver ion anti-bacterial drain panThe air filter has an anti-bacterial treatment to help prevent the growth of bacteria and mould on it.

Anti-bacterial air filter

FUNCTIONS

(1) standard setting (2) Ceiling soiling prevention setting

You can freely set air discharge settings by remote controller.

Swing pattern selection

Page 12: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

21 22

SPECIFICATIONS

CEILING MOUNTED CASSETTE TYPE

Cooling capacity1,3

Rated (Min. - Max.) kW

V1Y1

Btu/h

°CDB°CWB

Certified Operation range

Sound pressure level4

°CWBCertified Operation range

Motor outputCompressorCoil

ModelName

Indoor unit

Outdoor unit

Dimensions(HXWXD)Machine weight

Colour

mmmm

dB(A)

kWRefrigerant charge (R-410A) kg

dB(A)Dimensions (HXWXD) mm

Unit

Piping connections

mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit

Outdoor unit

Decoration panel

UnitDecoration panel

kgkg

UnitDecoration panel

Machine weight kg

Machine weight kg

Machine weight kg

Airflow rate (H/M/L) m3/mincfm

Outdoorunit

Colour

mm

Heat insulation

Max. interunit piping length mmMax. installation level difference

Power supply

Type

Cooling / Heating

Sound pressure level4 (H/M/L)

Indoorunit

Hermetically sealed scroll typeType Cross fin coil

43/37.5/32

32/26/20

298X840X84050X950X950

5.52421

2.2 3.0

84(V1), 83(Y1) 103(V1), 101(Y1)

3.75 2.9

108 101

----------

1 Phase, 220–230 V, 50 Hz3 Phase, 380-415 V, 50 Hz

30

Ivory white

Fresh white

Both liquid and gas piping

50 (Equivalent length 70)

VP25 (I.D 25XO.D 32)

1,130/918/706

-5 to 46-10 to 15

12 to 25°CDB 15 to 27

kWPower consumption Cooling1

44/39/34 44/40/36

33/28/22.51,165/988/794

Cooling Heating

Cooling Heating

7.1

35/31.5/28

50/52 53/56 54/56770X900X320 1,170X900X320

256X840X840

2.7(Charged for 30 m)

3.7(Charged for 30 m)

21/17.5/13.5741/618/477

Heating capacity2,3

Rated (Min. - Max.) kW

Btu/h8.0

2.72Heating2

CoolingHeating

2.85

W/WCOP 2.612.81

3.833.752.612.99

4.665.062.682.77

4.914.972.853.22

24,20010.0

34,10012.5

42,70014.0

47,800

27,300 11.2

38,200 14.0

47,800 16.0

54,600

Outdoor unit

Hermetically sealed scroll type

42/38/34235X1,590X690235X1,270X690

3832

28/24/2020.5/17/14988/847/706

38/36/34724/600/494

CEILING SUSPENDED TYPE

Ivory white

°CWB

kWBtu/h

kWPower consumption

°CDBCertified Operation range

Certified Operation range

Motor output

Cooling / Heating

CompressorCoil

Dimensions (HXWXD)

Colour

mmdB(A)

kWRefrigerant charge (R-410A) kg

dB(A)Sound pressure level4Dimensions (HXWXD) mm

Piping connections

mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit

Outdoor unit

Airflow rate (H/M/L) m3/min

Outdoorunit

Colour

mm

Heat insulation

Max. interunit piping length mmMax. installation level difference

TypeCross fin coilType

Sound pressure level4 (H/M/L)

Indoorunit

Cooling capacity1,3

Rated (Min. - Max.)

cfm44/41/37

31/27/231,094/953/812

Light ivory

°CWB

12 to 25°CDB 15 to 27

W/WCOP

46/42/38

34/29/241,200/1,024/847

Cooling1

kWBtu/h

Heating capacity2,3

Rated (Min. - Max.)

kWHeating2

CoolingHeating

CoolingHeating

CoolingHeating

1 Phase, 220–240 V, 50 Hz

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

Indoor unit

kWBtu/h

°CDB

°CWB

Cooling / Heating

Certified Operation range

Certified Operation range

Motor outputCompressorCoil

Indoorunit

Dimensions (HXWXD)Air filter6

Colour

mm

dB(A)

kWRefrigerant charge (R-410A)

Sound pressure level5

Sound pressure level5 (H/M/L)

dB(A)Dimensions (HXWXD) mm

Piping connections

mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit

kg

Airflow rate (H/M/L)Fan

Outdoorunit

Colour

Heat insulation

Max. interunit piping length mmMax. installation level difference

Type

----------

mmOutdoor unit

Ivory white

kWCooling1Power consumption

Pacfm

External static pressure4

Cooling capacity1,3

Rated (Min. - Max.)

°CWB

12 to 25°CDB 15 to 27

m3/min

245X1,000X800----------

37

Hermetically sealed scroll typeType Cross fin coil

7.1

2.2

2.71

Rated 50 (50-150)1,130/953/794

32/27/22.5812/688/56523/19.5/16

38/35.5/3338/35/33

3.0

245X1,400X80047

3.75 2.9

1,271/1,077/88336/30.5/25

40/37.5/35

kWBtu/h

Heating capacity2,3

Rated (Min. - Max.) 8.0

Heating2

CoolingHeating

CoolingHeating

CoolingHeating

2.49

W/WCOP 2.623.21

FLOOR STANDING TYPE

°CWB°CDBCooling

HeatingCertifiedOperation range

Sound pressure level4

°CWBCoolingHeating

CertifiedOperation range °CDB

Motor outputCompressor

Dimensions (HXWXD)

Colour

mmdB(A)

kWRefrigerant charge (R-410A) kg

dB(A)Dimensions (HXWXD) mm

Piping connections

mmLiquid (Flare)mmGas (Flare)mmDrain Indoor unit

Outdoor unit

Outdoorunit

Colour

mm

Heat insulation

Max. interunit piping length mmMax. installation level difference

TypeType

Cooling / Heating

Sound pressure level (H/M/L)4

Indoorunit

391,850X600X270

635/565/494

47

988/883/777

1,850X600X350

Ivory white Coil Cross fin coil

15 to 2712 to 25

988/918/847 1,059/988/91818/16/14 28/25/22 28/26/24 30/28/26

Fresh white

Hermetically sealed scroll type

Fan Airflow rate (H/M/L) m3/mincfm

43/41/38 50/47/44 51/48/46 53/51/48

24,200

27,300

10.0

3.78

11.2

3.912.652.86

34,100

38,200

12.5

4.67

14.0

4.522.683.10

42,700

47,800

14.0

5.02

16.0

4.912.793.26

47,800

54,600

Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3Capacities are net, including a deduction for cooling for indoor fan motor heat. 4The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal)

2Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3Capacities are net, including a deduction for cooling for indoor fan motor heat. 4External static pressure is changeable in 11 stages by remote controller. 5The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection. 6Air filter is not standard accessory, but please mount it in the duct system of the suction side. Select its dust collection efficiency(gravity method) 50% or more.

Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3Capacities are net, including a deduction for cooling for indoor fan motor heat.4The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

Note : 1Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB. Equiv. refrigeration piping, 7.5 m (horizontal). 2Rated heating capacities are based on the following conditions: Indoor temp., 20°CDB, 15°CWB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 7.5 m (horizontal) 3Capacities are net, including a deduction for cooling for indoor fan motor heat. 4The operation sound is measured in anechoic chamber. If it is measured under the actual installation conditions, it is normally over the set value due to environmental noise and sound reflection.

Machine weight kg

Machine weight kg

Machine weight kg

Machine weight kg

9.515.9

26.0 (Hole)

2.2 3.0

83 101

3.75 2.9

108 101

30Both liquid and gas piping

50 (Equivalent length 70)

VP20 (I.D 20XO.D 26)

-5 to 46-10 to 15

50/52 53/56 54/56770X900X320 1,170X900X320

2.7(Charged for 30 m)

3.7(Charged for 30 m)

9.515.9

26.0 (Hole)

71FCQ71KAVEA

RQ71MV1

100FCQ100KAVEA

RQ100MV1

RQ71MY1 RQ100MY1

125FCQ125KAVEA

RQ125MY1

140FCQ140KAVEA

RQ140MY1

V1Y1

ModelName

Indoor unit

Outdoor unit

Power supply1 Phase, 220–230 V, 50 Hz

3 Phase, 380-415 V, 50 HzOutdoor unit

71FBQ71EVE

RQ71MV1

100FBQ100EVE

RQ100MV1

RQ71MY1 RQ100MY1

125FBQ125EVE

RQ125MY1

140FBQ140EVE

RQ140MY1

ModelName

Indoor unit

Outdoor unitPower supply 3 Phase, 380-415 V, 50 HzOutdoor unit

71FHQ71DAVMA

100FHQ100DAVMA

RQ71MY1 RQ100MY1

125FHQ125DAVMA

RQ125MY1

140FHQ140DAVMA

RQ140MY1

V1Y1

ModelName

Indoor unit

Outdoor unit

Power supply 1 Phase, 220–230 V, 50 Hz3 Phase, 380-415 V, 50 Hz

Outdoor unit

71FVQ71CVEB

RQ71MV1

100FVQ100CVEB

RQ100MV1

RQ71MY1 RQ100MY1

125FVQ125CVEB

RQ125MY1

140FVQ140CVEB

RQ140MY1

84(V1), 83(Y1) 103(V1), 101(Y1) 108 101

30Both liquid and gas piping

50 (Equivalent length 70)

VP25 (I.D 25XO.D 32)

-5 to 46-10 to 15

50/52 53/56 54/56770X900X320 1,170X900X320

9.515.9

26.0 (Hole)

2.2 3.0

84(V1), 83(Y1) 103(V1), 101(Y1)

3.75 2.9

108 101

30Both liquid and gas piping

50 (Equivalent length 70)

VP20 (I.D 20XO.D 26)

-5 to 46-10 to 15

50/52 53/56 54/56770X900X320 1,170X900X320

2.7(Charged for 30 m)

3.7(Charged for 30 m)

9.515.9

26.0 (Hole)

7.1

8.0

2.702.852.632.81

3.754.132.672.71

4.515.002.772.80

4.874.942.873.24

24,20010.0

34,10012.5

42,70014.0

47,800

27,300 11.2

38,200 14.0

47,800 16.0

54,600kW

Btu/h

kWPower consumption

Cooling capacity1,3

Rated (Min. - Max.)

W/WCOP

Cooling1

kWBtu/h

Heating capacity2,3

Rated (Min. - Max.)

kWHeating2

CoolingHeating

7.1

8.0

2.873.042.472.63

3.953.752.532.99

4.794.672.573.00

5.445.282.573.03

24,20010.0

34,10012.3

42,00014.0

47,800

27,300 11.2

38,200 14.0

47,800 16.0

54,600

2.7(Charged for 30 m)

3.7(Charged for 30 m)

--------------------

----------

Page 13: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

intelligent Touch Controller2

Kit nameName of option

DCS302CA61DCS301BA61DST301BA61

Remark

Replacement long-life filter

L-type piping kit (for upward direction)Remote controller

Resin net

Wireless type

Central remote controller2

Unified ON/OFF controller2

Schedule timer2

Wiring adaptor for electrical appendicesWiring adaptor for electrical appendices3

Installation box for adaptor PCB

CEILING SUSPENDED TYPE

Note: 1Wiring for wired remote controller to be procured locally.2The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.3Installation box for adaptor PCB(KRP1D93A) is necessary.

FHQ71DAVMA FHQ100DAVMA FHQ125DAVMA FHQ140DAVMA

KRP1BA54DCS601C51

KRP4AA52

KAFP501A80 KAFP501A160

KJB311AAKJB212AA

Remote sensor (for indoor temperature)Electrical box with earth terminal (3 blocks)Electrical box with earth terminal (2 blocks)

BRC1C61BRC1E62Navigation Remote Controller Wired type1

Wired type1

Drain pump kitFresh air intake kit

KDU50P140VEKDDQ50A140

Heat pump BRC7GA53

KRP1D93A

KHFP5N160

KRCS01-4B

Indoor unit

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

FLOOR STANDING TYPEKit nameName of option FVQ71CVEB FVQ100CVEB

DCS302CA61DCS301BA61DST301BA61

KAFJ95L160

Remark

Replacement long-life filterBRC1C61Remote controller

Navigation Remote ControllerCentral remote controller2

Unified ON/OFF controller2

Schedule timer2

intelligent Touch Controller2

Adaptor for wiring3

Wiring adaptor for electrical appendicesInstallation box for adaptor PCB

Note: 1Wiring for wired remote controller to be procured locally. 2The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.3Installation box for adaptor PCB (KRP4AA95) is necessary.

FVQ125CVEB FVQ140CVEB

KRP1BA57DCS601C51

KRP4AA52KRP4AA95

BRC1E62Wired type1Wired type1

Only one mounting plate can be installed for each indoor unit.Mounting plate is necessary for each adaptor marked .

FBQ71EVE FBQ100EVE FBQ125EVE FBQ140EVEName of option Remark

High-efficiency filter1

Filter chamber(for rear suction)1

Long-life filter1

Air discharge adaptor

Adaptor for wiring Wiring adaptor for electrical appendices(2)Remote sensorMounting plate for adaptor PCB.3,4,5

Central remote controller6

Unified ON/OFF controller6

Schedule timer6

intelligent Touch Controller6

Service panel

Remote controller

65%90%

WhiteFresh whiteBrown

Wired type2

Wired type2

Wireless type

Kit name

KAFP632B80

Shield plate for side plate

Navigation Remote Controller

KAFP632B160KAFP633B80 KAFP633B160KDDFP63B80 KDDFP63B160KAFP631B80 KAFP631B160KTBJ25K80W KTBJ25K160WKTBJ25K80F KTBJ25K160FKTBJ25K80T KTBJ25K160TKDAP25A71A

KDBD63A160Heat pump BRC4C65

BRC1C61BRC1E62

KRCS01-4BKRP4A98

DCS302CA61DCS301BA61DST301BA61DCS601C51

KDAP25A140A

Note: 1If installing high efficiency filter and long-life filter to the unit, filter chamber is required.

3

4Up to 2 adaptors can be fixed for each mounting plate.2Wiring for wired remote controller to be procured locally. 5

6The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary.

KRP1C64KRP4AA51

Outdoor unitKit name

RQ71MV1 RQ100MV1RQ71MY1 RQ100MY1 RQ125MY1 RQ140MY1

Heat pump

Central drain plug

Name of option

KKPJ5F180

23 24

OPTIONS

Indoor unit

intelligent Touch Controller5

Note: 1Refer to page 6 for the details.2Please order using the names of both components instead of set name. 3Required for installing high-efficiency filter unit and ultra long-life filter unit. 4Wiring for wired remote controller to be procured locally.5The indoor unit is equipped standardly with the interface adaptor for SkyAir series. An option is unnecessary. 6Installation box for adaptor PCB (KRP1H98A) is necessary.

CEILING MOUNTED CASSETTE TYPEKit name

KDJP55B160KDJP55B80

KAFP556C80KAFP557C80KAFP552B80KAFP553B80

KAFP556C160KAFP557C160KAFP552B160KAFP553B160

FCQ71KAVEA FCQ100KAVEA FCQ125KAVEA FCQ140KAVEAName of option Remark

Chamber type

Decoration panel

Fresh air intake kit1

Central remote controller5

Unified ON/OFF controller5

Schedule timer5

Adaptor for wiring6

Without T-duct jointWith T-duct joint

Direct installation type

Sealing material of air discharge outletPanel spacer

Wiring adaptor for electrical appendices(2)6

Installation box for adaptor PCB

High-efficiency filter unit (including filter chamber)

(Colorimetric method 65%)(Colorimetric method 90%)

Replacement high-efficiency filter

(Colorimetric method 65%)(Colorimetric method 90%)

Remote controller Wireless type

Wired type4 Wired type4

Branch duct chamber

Remote sensor (for indoor temperature)

DCS601C51

DCS302CA61DCS301BA61DST301BA61

KRP1C63

KDBH55K160FKDBP55H160FA

KDDP55B160 (Components:KDDP55C160-1, KDDP55B160-2)2

KDDP55B160K (Components:KDDP55C160-1, KDDP55B160K2)2

KDDP55X160A

KRP4AA53

Heat pump BRC7F634F

BYCP125K-W1

KRP1H98AKRCS01-4B

BRC1E62BRC1C61

KDDFP55C160Filter chamber

Navigation Remote Controller

KDTP55K160Chamber connection kit3Insulation kit for high humidity

KKSJ55KA160KDTP55K80

For each flow pattern – all round, 4-way, 3-way, 2-way, branch duct connection – the compatibility of each independently installed option (shown in the column on the left) to accessory options (listed across the top of each table) is shown in the cells where the relevant row and column intersect.A circle (o) indicates compatibility, and a cross (x) indicates incompatibility. Any options not shown below are not suitable for independent or accessory installation.

Round flow type: List of optional parts required to achieve different flow patterns

1In some cases, depending on how the unit is embedded in the ceiling, use of branch ducts and fresh air intake kits may not be possible. Before starting installation work make sure to check whether or not joint installation is possible. In particular, ensure that the lower fixing position caused by the addition of panel spacers is acceptable.

2Use a chamber connection kit if two different types of optional chamber are used together. In this case, the fresh air intake kit must be installed in the upper position.3It is not possible to use panel spacers in a 2-way flow installation. 4It is not possible to install a branch duct on the same side to which a fresh air intake kit (direct mount) is installed.

Panel/grille relatedIndependently installable optional parts

Operation control relatedAuxillary function related

Filter related

Optional accessory parts

Independently installable optional partsOptional accessory parts

Independently installable optional partsOptional accessory parts

Panel spacer1

Panel spacer1 o o ox oWireless remote controller o o oo o

Fresh air intake kit (Direct installation type) o o oo ox o o

xx

High-efficiency filter unit2

Filter related Ultra-long-life filter unit2

o o ox

xUltra-long-life filter unit2 o o o xx

Insulation kit for high humidity

Panel/grille relatedOperation control relatedAuxillary function related

Panel spacer1

Wireless remote controller

Fresh air intake kit (Direct installation type)Insulation kit for high humidity

All round flow 4-way flow

o3 o3 xx o3

o3 o

x

xxo o

o3 o xx

o ox o o x

o3 o o xx

3-way flow 2-way flow

1-way branch / unit 3-way flowBranch duct chamber 1(Round duct type)

o o o4 xx o2-way branch / unit 2-way flow1-way branch / unit 2-way flow

x o o4 xx ox o o4 xx o

Branch duct connection

Wireless remote controller

Fresh air intake kit(Direct installation type)

High-efficiency filter unit2

Insulation kit for high humidity

Ultra-long-life filter unit2

Panel spacer1 Wireless remote controller

Fresh air intake kit(Direct installation type)

High-efficiency filter unit2

Insulation kit for high humidity

Ultra-long-life filter unit2

Panel spacer1 Wireless remote controller

Fresh air intake kit(Direct installation type)

Fresh air intake kit (Chamber type)1,2 o o ox o

Fresh air intake kit (Chamber type)1,2 o3 o xx o

oo

xoo

o3

o

x

x

x

o

o o o

Fresh air intake kit (Chamber type)1,2

Fresh air intake kit (Chamber type)1,2

Fresh air intake kit (Chamber type)1,2

High-efficiencyfilter unit2

Insulation kit for high humidity

Ultra-long-life filter unit2

KAFP551K160KAFP55C160

KAFP55H160H

Replacement long-life filterUltra long-life filter unit (including filter chamber)Replacement ultra long-life filter

Page 14: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

CEILING MOUNTED CASSETTE TYPE

Notes:1Sticking location for manufacture's label manufacture's label for indoor unit: Suction grille inner side's electric components box's lid surface manufacture's label for decoration panel : Decoration panel's corner decoration cover inner surface2In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.

3When the temperature and humidity in the ceiling exceed 30˚C and RH 80% or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more of glasswool or polyethylene form) is required.

4Though the installation is acceptable up to maximum of 910mm square ceiling opening, keep the clearance of 35mm or less between the indoor unit and the ceiling opening so that

the panel overlap allowance can be ensured.5Please do not place the thing been damp and troubled under an indoor unit. When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.

950

950

arrow viewA

Piping ConnectionSide

Drain ConnectionSide

Note 28

6

7

860~910(Ceiling opening space) (Note 4)710(Hanging bolt pitch)

420

420

780(

Hang

ing

bolt

pitc

h)86

0~91

0(Ceili

ng op

ening

space

) (Note

4)

300or less

9

B

C

(round shape type)

840340

80 80124

55 55

256

124

110

95

40

29

850

175

Adjus

table(

0~67

5)

10246

160

50

165

125

Connection positionof branch duct(square-shaped type)

4 1 2

2 100=200

16-M4 Prepared hole

Connection positionof branch duct

Hanging bolt4-M8~M10

C/L20157

350280330 15

00 or

more

(requ

ired s

pace

)Fro

m the flo

or side

2500 or

more

Connection positionof branch duct(square-shaped type)

Connection positionof branch duct(round shape type)

27-M4 Prepared hole

35 or less(Note 4)

35 or less (Note 4)

A

For h

eight

instal

lation

81

124

2x100=200

157

124

105

64

55840

110

350

160

13095

50

256

58555

604215

0

3

Connection positionof branch duct(round shape type)

Connection positionof branch duct(square-shaped type)

16-M4 Hole

arrow viewB

95

85

350

C/L124

81

110

160

2x100=200

124

157

[FCQ71KAVEA]

20-M4Prepared hole

Connection positionof branch duct(square-shaped type)

Connection positionof branch duct(round shape type)Connection positionof fresh air intake kit(direct installation type)

ø100(knock hole)

arrow viewC

2x100=

200

160

C/L 350

124

95109

80

90

183

25

90

157

80213

124

[FCQ71KAVEA]

C/L

160167679529

93

90196

8080

16025

90213

157

350

20-M4Prepared hole

Connection positionof branch duct(square-shaped type)

Connection positionof branch duct(round shape type)Connection positionof fresh air intake kit(direct installation type)

ø100(knock hole)

arrow viewC

2 10

0=20

0

[FCQ100-140KAVEA]

1500

or m

ore(re

quire

d spa

ce)

From th

e floor s

ide 250

0 or mo

reFo

r heig

ht ins

tallat

ion

5064 160

256157350

1309560105

150

42

9367

2916

0

167

840 555581 85

Connection positionof branch duct(square-shaped type)

Connection positionof branch duct(round shape type)

27-M4 Prepared hole

35 or less35 or less (Note 4)(Note 4)

3

5

A

2 100=200

[FCQ71KAVEA] [FCQ71KAVEA]

[FCQ100-140KAVEA]

[FCQ71-140KAVEA] [FCQ71-140KAVEA]

[FCQ100-140KAVEA]

2 100=200

160

C/L160

157350

81 85

67

167

9529

93

Connection positionof branch duct(round shape type)

Connection positionof branch duct(square-shaped type)

16-M4 Hole

arrow viewB

[FCQ100-140KAVEA]

Adjus

table(

0~67

5)

Connection positionof branch duct(square-shaped type)

16-M4 Prepared hole

(round shape type)

Connection positionof branch duct

Hanging bolt4-M8~M10 1

160850

280

80

10

330

340

50

55

4

55

40

80

12529

95

157

298

167

160

350

175

16528

8

20

2 100=200

2

840

160

C/LThe necessary space is 500mm or more when the air-outlet is blocked with the accessory.Moreover when the corner areas are blocked (both right and left of the blocked air outlet), the necessary space is 200mm or more.

1500mm or more200mm or more

1500mm or more

1500mm or more1500mm

or more200mmor more

Required space

Liquid pipe connectionGas pipe connectionDrain pipe connectionTransmission wiring connectionRemote controller wiring connectionAir-outletSuction grilleCorner decoration coverDrain hose (accessory)

12345

6789

DIMENSIONS (Unit: mm)

57

131

φ45

19791

6

4 5 11

14

197

5

57

690

(Req

uire

d sp

ace)

For h

eight

instal

lation

From t

he floo

r side

2500 o

r more

Floor side

(Req

uired

spac

e)

Obstacle

300 o

r mor

e

131270

235

30 or more(Service space)

30 or more(Service space)

4-M8~M10Hanging bolt

1

268

156

83

214

221

76

268

105

(Note.2)Brand name plate

The Front

(For left pipe)Drain piping connection VP20 6

45723

57

1230

87

195

35

102

(Han

ging

bo

lt pi

tch)

210

116

(Hanging bolt pitch)

210

131

105

30

100

156

260

189

163

8

18

10

17 1620

5

220103

175

Position : Hole of wall for taking out in pipe back(View from the front)

(Req

uire

d sp

ace)

19 15

120

90

51

92 63

606340

134 59

157

115

90

175

Position slit hole for taking out in pipe back(View from the front)

Connection position of fresh air intake kitφ100(Knock out hole)

12

9

Notes:1

2

3

Location of unit's Name Plate: Bottom of fan housing inside the suction grille.In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.Please do not place the thing been damp and troubled under an indoor unit.When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.

CEILING SUSPENDED TYPE

[FHQ71DAVMA]

1234567891011121314151617181920

Air discharge grilleAir suction grilleAir filterGas pipe connectionLiquid pipe connection Drain pipe connectionEarth terminal (inside the control box) (M4)HangerRear pipe penetration coverTop panel penetration coverRight side pipe connection Left back drain pipe connection Left side drain pipe connection Right side drain pipe connection Hole of wall for taking out in pipe back Upward drain pipe connection Upward gas pipe connection Upward liquid pipe connection Power supply wiring and a unit wiring back connectionPower supply wiring and a unit wiring upper connection

131

57

197

φ45

91

6

4 5 11

1457

519

7

690

Floor side

(Req

uired

spac

e)

Obstacle

300 o

r mor

e

For h

eight

instal

lation

From t

he floo

r side

2500 o

r more

(Req

uire

d sp

ace)

13

235

159030 or more(Service space)

30 or more(Service space)

4-M8~M10Hanging bolt

1

156

83

268

221

10576

268

214

The Front

(Note.2)Brand name plate

(For left pipe)Drain piping connection VP20

6

45723

189

57102

35

210

156

131

30 87

260

210

105

19516

3

116

100

1550(Hanging bolt pitch)

(Han

ging

bo

lt pi

tch)

8

18

10

17 1620

103220

517

5(R

equi

red

spac

e)

Position : Hole of wall for taking out in pipe back(View from the front)

19 15

15790

60

175

59

92

12090

6313451

40

115

63

Connection position of fresh air intake kitφ100(Knock out hole)

Position slit hole for taking out in pipe back(View from the front)

12

9

Notes:1

2

3

Location of unit's Name Plate: Bottom of fan housing inside the suction grille.In case of using wireless remote controller, this position will be a signal receiver. Refer to the drawing of wireless remote controller in detail.Please do not place the thing been damp and troubled under an indoor unit.When the case where humidity is 80% or more, and the drain outlet are choked up and the air filter are dirty, dew may fall.

[FHQ100-140DAVMA]

1234567891011121314151617181920

Air discharge grilleAir suction grilleAir filterGas pipe connectionLiquid pipe connection Drain pipe connectionEarth terminal (inside the control box) (M4)HangerRear pipe penetration coverTop panel penetration coverRight side pipe connection Left back drain pipe connection Left side drain pipe connection Right side drain pipe connection Hole of wall for taking out in pipe back Upward drain pipe connection Upward gas pipe connection Upward liquid pipe connection Power supply wiring and a unit wiring back connectionPower supply wiring and a unit wiring upper connection

CEILING SUSPENDED TYPE

25 26

Page 15: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

27 28

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

Notes:1Locations of Manufacturer's Label:Surface of a control box2Make sure to mount the air filter inside the air passage on the suction side. (Select Duct Collection Efficiency <Gravimetric Method>50% or more.)3If the temperature and humidity in the ceiling is likely to exceed 30℃ and RH80%, strengthen heat insulation by applying the additional insulation materials such as glass wool or polyethylene that has thickness of 10mm or more.4Do not put things that should not get wet under the indoor unit. Dews may drop when humidity reaches over 80%, a drain gets stuck or air filters are not clean.5Space for Service Works

1)Inspection hatch 1and 2(450x450) (Fig.A-1) and a space of 300mm or more under the unit. (Fig.A) Note:Inspection hatch 2 is not needed when there is a space for service work under the unit.2)Inspection hatch 1(450x450) on the control box side, and Inspection hatch 2 under the unit. (View B-1)3)Inspection hatch 3 under the unit and control box. (View B-2)

Provide service spaces for service work such as check and maintenance of the control box and drain pump by one of the following ways.

Provide enough space for maintenance and mount the drainpan and control box.Check the drawing of optional accessories when mounting optional accessories such as filter chamber and humidifier.

Liquid pipe connection1Gas pipe connection2Drain pipe connection3Earth terminal(terminal in Control box)4Control box(Inside)5

Remote control wiring connection6Power supply wiring connection7Air discharge flange8Air suction flange9Hanger10

Socket(For maintenance)11Drain hose(Accessory)12Drain hose connection(Accessory)13

[FBQ71EVE]

2500

or m

ore

5x156=780

176

194

815

100

792

1000

500

207

Airoutlet

12

4

2

69

226

6x150=900

977

6020

8

952

36-φ4.7hole

1

200 o

r less

Inspection hatch 2450 or more

11

※When can work enters the space under the unit, inspection hatch 2 is unnecessary.

18-8x12 oblong hole

(A c

ase

with

out

the

ceilin

g)

630

7

10

450

or m

ore

Air inlet(Note.2)

245

134

( )Drain pan removaland part exchange.

850

or le

ss

(Hanging bolt position)

499

Ceiling

450

1038

(Han

ging

bol

t pos

ition

)

Floor surface

(Not

e.5)

38

(All around)

Drain pan maintenancecheck hole

(From the Air inlet)

(643

or l

ess)

(Service space)

(All around)13

8

Inspection hatch 1450 or more

123

CeilingInspection hatch

300

or m

ore

Fig.A

Control boxCASE1)

6

65

800 or more

16-8x12 oblonghole

13x6

5=84

5 1000

or m

ore

3x50

=150

(All around) Inspection hatch 1(450x450)

835

800 or more

Control box

(All around)

9

(Ser

vice

spa

ce)

136

26

(SAME AS THE INDOORUNIT SIZE +300 OR MORE)

200

or le

ss

Control Boxmaintenance space

300

800 or more

50

Adju

stab

le

13

1300

or m

ore

8

View B-1

Airoutlet

300

or m

ore

30-φ4.7hole

183

5

179

(SAME AS THE INDOORUNIT SIZE OR MORE)

300 or less

Control box

53

222

Drain panmaintenance space

91

Inspection hatch 3

800

3

11x6

5=71

5

View B-2

2x50

=100

Inspection hatch 2

(From the Air outlet)

View

Air inlet

Air outlet

Inspection hatch 2※(450X450)

200

or le

ss

Control box

Inspection hatch1(450x450)

Unit base

Fig. A-1Suspention bolt(4pieces)

Air inlet

500Inspection hatch

CeilingB

CASE 2),3) Control box

20 or

more

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

Liquid pipe connection1Gas pipe connection2Drain pipe connection3Earth terminal(terminal in Control box)4Control box(Inside)5

Remote control wiring connection6Power supply wiring connection7Air discharge flange8Air suction flange9Hanger10

Socket(For maintenance)11Drain hose(Accessory)12Drain hose connection(Accessory)13

[FBQ100-140EVE]

2500

or m

ore

1400

500

207

Airoutlet

69

50-φ4.7hole

200 o

r less

※When can work enters the space under the unit, inspection hatch 2 is unnecessary.

26-8x12 oblong hole

(A c

ase

with

out

the

ceilin

g)

630

450

or m

ore

Air inlet(Note.2)24

5

134

Inspection hatch 2450 or more

( )Drain pan removaland part exchange.

850 o

r less

(Hanging bolt position)

Ceiling

650

1438

(Han

ging

bol

t pos

ition

)

Floor surface

(Not

e.5)

38

(All around)

Drain pan maintenancecheck hole (From the Air inlet)

(643 o

r less

)

(Service space)

(All around)

Inspection hatch 1450 or more

65

20-8x12 oblonghole

20x6

5=13

003x

50=1

50

(All around)

800 or more

(All around)

(Ser

vice

spa

ce)

136

26Control Boxmaintenance space

30050

Adju

stab

le

Airoutlet

300

or m

ore

44-φ4.7hole

183

179

300 or less

53

Drain panmaintenance space

91

800

2x50

=100

(From the Air outlet)View

Air inlet

Air outlet

Inspection hatch 2※(450X450)

200

or le

ss

CeilingInspection hatch

300 o

r more

Fig.A

Control boxCASE1)

800 or moreControl box

Inspection hatch 1(450x450)

Control box

Inspection hatch1(450x450)

Unit base

Fig. A-1

(SAME AS THE INDOORUNIT SIZE +300 OR MORE)

bolt Suspention(4pieces)

200

or le

ss

Air inlet

500

1700

or m

ore

Control box

Inspection hatch 3

View B-2

1400

or m

ore

800 or moreView B-1

(SAME AS THE INDOORUNIT SIZE OR MORE)

Inspection hatch 2

18x6

5=11

70

7x156=10921192

100100

1

8

52699

176

60

9

1215

13524 7 100

1377

6x150=900

138

12

226

13

222

100

6

208

1235

10

3

11

194

100

123

Inspection hatchCeiling

CASE 2),3) Control box

20 or

more

DIMENSIONS (Unit: mm)

Notes:1Locations of Manufacturer's Label:Surface of a control box2Make sure to mount the air filter inside the air passage on the suction side. (Select Duct Collection Efficiency <Gravimetric Method>50% or more.)3If the temperature and humidity in the ceiling is likely to exceed 30℃ and RH80%, strengthen heat insulation by applying the additional insulation materials such as glass wool or polyethylene that has thickness of 10mm or more.4Do not put things that should not get wet under the indoor unit. Dews may drop when humidity reaches over 80%, a drain gets stuck or air filters are not clean.5Space for Service Works

1)Inspection hatch 1and 2(450x450) (Fig.A-1) and a space of 300mm or more under the unit. (Fig.A) Note:Inspection hatch 2 is not needed when there is a space for service work under the unit.2)Inspection hatch 1(450x450) on the control box side, and Inspection hatch 2 under the unit. (View B-1)3)Inspection hatch 3 under the unit and control box. (View B-2)

Provide service spaces for service work such as check and maintenance of the control box and drain pump by one of the following ways.

Provide enough space for maintenance and mount the drainpan and control box.Check the drawing of optional accessories when mounting optional accessories such as filter chamber and humidifier.

This model to be fixed with fixture as shown below.

In case of fixing it at the bottomIn case vibration resistance is required, fix it at both the bottom and the rear.

50 or more

1500 or more

50 or more

Required space

AB

100

C

50

Detail

0.7

Suction grille stopper

(Two both sides)

18

2-7X15 oblong hole

184 184

(For wood screw)

(Accessory)

330 30

Fixture

95

6

66E

G

68

Full open position of suction grille

H

Pull out direction of air-filter

F

D

75

KJ

L

740

or m

ore

(Pull

out d

imen

sion o

f air-

filter

)

5010

0

Approx.46

2

1

3

5

4

200

34 223

825

600

1850

314

253

95

598

677

616

541

8

9

10

130 215 126

PN

260

M

130

View

7

4- 14 Hole(For bolt)

FLOOR STANDING TYPE

Notes: 1Sticking location for manufacturer’s label: on the surface of cover of switch box inside the suction grille. 130

A

FVQ100/125/140CVEB50

190

B110

266

C186

350

D270

44

E45

49

F50

130

G50

190

H110

260

J180

266

K186

322

L242

79

M57

202

N144

229

P149FVQ71CVEB

Suction grilleAir filterThrough hole for side piping(70x90 oblong slit hole)Through hole for side piping( 80 slit hole)Through hole for side piping( 27 slit hole)Through hole for rear piping/wiring(80x130 oblong slit hole)Through hole for bottom piping/wiring(126x130 square hole)Liquid pipe connectionGas pipe connectionDrain pipe connection

123

4

5

6

7

8910

[FVQ71-140CVEB]

Page 16: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

OUTDOOR UNIT // RQ71MV1/MY1

OUTDOOR UNIT // RQ100MV1/MY1

102

60

52

6

191

7

5

95

422

55423

19

16

570

80

142

117

145

84

24

45

8

5495

7

55

1170

95

Hole for anchor bolt4-M12

350

38

36

30

1989

89140140 620

900

56 320

3030

(345

~355

)

71

223

67

16

3

54

6

4

89

2

5

53

17

65

13

58

376

Gas pipe connectionLiquid pipe connectionService port Grounding terminalRefrigerant piping intakePower supply wiring intakeControl wiring intakeDrain pipe connection

12345678

Gas pipe connectionLiquid pipe connectionService port Grounding terminalRefrigerant piping intakePower supply wiring intakeControl wiring intakeDrain pipe connection

12345678

29 30

DIMENSIONS (Unit: mm)

140 620

102

89

6

5

3

5

4

54

320

900

52

16

84

24

142

7

376

5

6716

38

117

89

7

569560

54

140

1

19145

19

13

350

770

339

289

9595 223

191

6

30

70

30

8

58

8055

5345

71

36 3034

1

55

Hole for anchor bolt4-M12

(345

~355

)

OUTDOOR UNIT // RQ125/140MY1

12345678

Gas pipe connectionLiquid pipe connectionService port Grounding terminalRefrigerant piping intakePower supply wiring intakeControl wiring intakeDrain pipe connection

320

5

7

1170

24

422

145

8 71

Hole for anchor bolt4-M12

45

19

84

102

6

89

900

6

36

9595

60

350

13

58

140

55

54

4

423

5

89

1638

67

55

(345

~355

)

80

89

30

95

5319 52

142

191

70

376

30

7

5

2

7

54

3140

117

16

56

30

223

1

5

620

6

Page 17: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

31 32

REMOTE CONTROLLER

Wired type

Staple

Remote controller

17

17

0~5

117

Remote controller

Remote controller

(Between remote controller and control box)

17

• Installation methodA Exposed body, exposed cord C Exposed body, embedded codeB Exposed body, embedded cord

Conduit

Control box

Through hole

Size

Specifications of cord

0.75~1.25 mm2

Total length 500 m

Type Shield wire (insulated thickness: 1 mm or more)Note) 1. Remote controller cord and staple are not

attached. They are field supplied parts.

120

120

17 18

42

84

38

Cord outlet hole2823

46

• Remote controller dimensions

Wireless typeCEILING MOUNTED CASSETTE TYPE <Round Flow>• Remote controller dimensions

• Remote controller holderinstallation procedure<installation to wall surface>

• Receiver installation procedure

• Receiver detail

Transmitting part

157

62 17.5

Liquid crystalremote controller(wireless)

Remote controllerholder

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE

120

72 83.5

106

(Ceil

ing o

penin

g)

70 180.5

35 49

Service space for ceiling installation

• Receiver detail

Note :

Mor

e th

an 9

0(S

revi

ce s

pace

)

(Ceiling opening)

2-5x9 Slot

Switch box(field Supplied parts)

Do not install more than 3 receivers in the vicinity of one another.With 4 or more units, there is always the possibility of malfunction

( 12- 16)

Receiver

Drain pipingside

Refrigerantpiping side

Decoration panel

BRC1C61

19

Upper case Lower case

40

2346

2848.5

4284

5X7 oblong hole

Code outlet hole5X15 oblong hole

Lower case portion

Lower case portion

Staple

19

A Exposed cord C Embedded cord(use switch box)

B Embedded cord

84

46Switch box for two switchex.) KJB211A(optional accessory)

Condit

19

0~5

Switch box [field supplied part]

(Between remotecontroller and control box)

48.5

19

Note)2Through hole

40

( 8- 10)

84

28

Switch box for one switchex.) KJB111A(optional accessory)

• Installation method

2.If the hole size is too large or the location is not proper, the hole may come out from the remote controller.

Note) 1. Remote controller cord and staple are not attached. They are field

supplied parts.

Size

Specifications of cord

0.75~1.25 mm2

Total length 500 m

Type Vinyl cord with sheath or cable (insulated thickness: 1mm or more)

BRC1E62

(Green)120

120

   Operationlamp

Top left outlet

Left outlet

Top centeroutlet

CEILING SUSPENDED TYPE

• Receiver installation procedure

Receiver

• Receiver detail

The Front

DIMENSIONS (Unit: mm)

1000

or more

300(200)

or more

L H

L H

H

L

500

or more

100(50)

or more

L H

For RQ71/100MV1, RQ71-140MY1

300(200)

or more

1000 or more

200 or more

100

or more

100 or more 100 or more

100(50)

or more

500 or more

When there are obstructions on the inlet side and both lateral sides

2. For series installation (more than two units)When there are obstructions on both sides

1. For single unit installation When there is an obstruction only on the inlet side

1. For single unit installation When there is an obstruction on the inlet side

2) When there is an obstruction in the overhead space

When there are obstructions on both sides

When there are obstructions on the inlet side and both lateral sides

2. For series installation (more than two units)

1. For single unit installation

2. For series installation (more than two units)

1. For single unit installation

2. For series installation (more than two units)

1. For single unit installation

2. For series installation (more than two units)

100

or more

500 or less

1000

or m

ore

An obstruction in the overhead space

500 or less

500 or more

1000

or m

ore

An obstruction in the overhead space

500 or less

1000 or more

1000

or m

ore

An obstruction in the overhead space

150

or more

150 or more 150 or more

500 or less

1000

or m

oreAn obstruction

in the overhead space

300(200)

or more

1000 or more

200 or more

500 or less

1000

or m

ore

An obstruction in the overhead space

1000 or more

1) When the overhead space is open

2) When there is an obstruction in the overhead space

1) When the overhead space is open

When there is an obstruction on the inlet side1 When there is an obstruction on the outlet side2

1) When the overhead space is open (There is no limit to the height of the obstruction on the outlet side.)

When there are obstructions on both the inlet and outlet sides(When the obstruction on the outlet side is higher than the unit itself)

3

Note : As for other patterns of installation, please refer to Installation manual or Engineering Data Book.

Installation service space for outdoor unit

The values in ( ) are for RQ71 type. (Unit: mm)

Page 18: Air Conditioning System · A built-in antibacterial treatment that uses silver ion in the drain pan prevents

33 34

MEMO