TRAININING COURSE
ONBUILDING SERVICES
AIR CONDITIONING, HEATING AND VENTILATION
IN BUILDING (HVAC SERVICE)
Prepared by
Eng. M.H.M. Shafiqul Islam
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 2/37
1.1 Types of Air Conditioning plants
1. Definition of Air Conditioning: Air Conditioning is defined as the
simultaneous control of temperature, humidity, motion and quality of
atmosphere within an enclosed space.
The functions of air-conditioning system are:
1. Temperature control (cooling and heating).
2. Humidity control3. Air filtering and purification.
4. Air movement and circulation.
5. Noise level control.
Summer comfort condition for human:
Temperature range : 74 0F - 78 0F
Humidity range: 50% - 60%
Air movement : 15 fpm-25fpm
Types of Air Conditioning plants:
Air-conditioning systems are classified broadly into the following types:
1. Direct expansion system (DX)
2. Central air conditioning system
3. Heat pump.
1. Direct expansion system (DX):
It is a self-contained compact unit located within or next to the air
conditioned space and consists of minimum essential components for producing
cooling effect. This system may be subdivided:
i) Room air conditioning unit (window type).
ii) Split air conditioning unit.
2
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 3/37
iii) Single package air conditioning unit.
i) Room air conditioner: A room air-condition can be described as a self-
contained unit either mounted in a window through a wall or as a console.
ii) Split air-conditioning unit: This system consists of two individual
factory assembled units called indoor and outdoor unit separated from
each other but connected together by piping.
iii) Single package air-conditioning unit: This type of unit has both the
condensing and evaporating units in one package. Duct system is required
for conveying the conditioned air from the evaporating unit to the space
being conditioned.The above type air conditioners are low in cooling capacity and suitable
for using in small aid medium size room.
2. Central air-conditioning system:
Central air-conditioning system is generally divided into three basic types
of the methods through which the final space cooling and heating are attained.
These are as follows:i) All-air system.
ii) All-water system.
iii) Air-water system.
i) All-air system: Both the air treating and refrigeration plants may be
remotely located in separate room from the conditioned space. Only the
final cooling-heating medium (air) is brought into the condition spacethrough duct networks and air outlets.
Secondary refrigerant (i.e. chilled water) is supplied to the air-handling
unit from the refrigeration unit located in a remote plant room.
ii) All-water system: A cooling medium (chilled water) is supplied from a
remote refrigeration unit and circulated through coils of air terminal unit
3
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 4/37
(FCU) installed within the conditioned space.
4
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 5/37
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 6/37
The unit must be grounded to prevent possible hazards due to insulation
failures.
Power supply should be within the rated voltage.
Operation of the central plant is somewhat different from self-contained
unit. A well-sequenced operation procedure should be maintained and
operation should be carried out through trained/skilled staffs as per operation
manual. Record and checklist card should be maintained for each machine.
Maintenance:
Preventive maintenance is used for air conditioning plants. It
prevents down time occurring due to failure.
A checklist is prepared for weekly, monthly, half-yearly and annual
checks.
The essential aims of proper maintenance are:
Cleanliness (Clean filler regularly)
Correct lubrication
Proper electrical protection and control.
Correct tightness and leakage free performance.
Proper function of safety devices.
Relevant BNBC/93 codes for installation, Operation, and maintenance
of air conditioning plants.
3.5.1.5 Equipment Installation
a) General: Mechanical equipment and appliances shall be installed in
accordance with the manufacturer’s installation instructions for the labelled
equipment. Connections to mechanical equipment or appliances such as fuel
supply, electrical, hydraulic piping, vent and ducts shall conform to the
requirements of this code.
6
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 7/37
b) Clearance: Appliances shall be installed with the minimum clearances to
combustibles for which the appliance has been tested as specified by the
manufacturer.
c) Anchorage of Appliances: Appliances designed to be fixed in position
shall be securely fastened in position. Supports for appliances shall be
designed and constructed to sustain vertical and horizontal loads within
the stress limitations specified in the Building Code.
d) Noise and Vibration: Equipment noise and vibration transmitted to the
occupied space shall not exceed the recommended value for the space. Selection
and installation of equipment shall be in accordance with Sec. 3.3.3.d) Identification of Equipment: When more than one air-conditioning,
heating, refrigerating or ventilation systems are installed on the roof of a
building or within the building, each equipment shall be identified as to
the area or space served by the equipment.
3.10.2 Operation
A well sequenced operation procedure shall be followed to ensureeffective operation of the air-conditioning, heating and ventilation
system, safety from hazard to personnel and property. Operation
procedure shall take account for saving in energy use.
All operation data of all the machinery and equipment shall be properly
preserved for future reference for maintenance purposes.
3.10.3 MaintenanceA well designed maintenance program for the air-conditioning, heating and
ventilation system shall be implemented in order to achieve the following:
a) Optimum reliability and continuity of service.
b) Extended longevity and economic life.
c) Functional effectiveness, whereby the intended performance of
mechanical equipment and system can be fully attained.
7
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 8/37
d) Minimum operating cost, attendant requirements, servicing and repairs.
e) Safety from hazard to personnel and property.
Maintenance program and procedure shall comply with the instructions of
machinery/equipment manufacturers in this regard.
1.2 Refrigeration Cycles
Fundamentals
For an understanding of refrigeration and air conditioning, it is necessary
to know some fundamentals, technical/scientific terms and definitions.
Temperature:Temperature is an indication of the level of heat in a substance. A
thermometer is the instrument used for the measurement of temperature. There
are three different types of temperature: dry-bulb, wet-bulb and dew-point.
Dry-bulb temperature is the temperature that measured by an ordinary
thermometer.
Wet-bulb temperature is a measurement used to evaluate the humidity of air.
Dew-point temperature is the temperature at which vapour (at 100% humidity)
begins to condense.
Heat: Heat is a form of energy that causes molecules to move and raises the
temperature of a substance. It is measured in BTU/Calorie.
One BTU is defined as the amount of heat to be added (removed) to raise
(lower) the temperature of one pound of water by one degree Fahrenheit (1 0F).
There are three types of heat in air-conditioning and refrigeration: specific heat,
sensible heat and latent heat.
Specific heat is the amount of heat in BTU to raise the temperature of 1 lb of a
substance by 1 0F.
Sensible heat: Heat that changes the temperature of a substance. It can be
sensed on a thermometer.
8
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 9/37
Latent Heat: heat that causes a change of state of substance with no change in
temperature or pressure.
There are different types of latent heat in refrigeration system.
Latent heat of condensation: The amount of heat released by a substance to
change its state from a vapor (gas) to a liquid.
Latent heat of fusion: The amount of heat that must be added to a solid to
change it to a liquid.
Latent heat of vaporization: The amount of heat that must be required to a
substance to change it from a liquid to a vapor.
Pressure: Force per unit area measured on either the absolute or atmospheric(gauge) scale. PSIA (LB/sq. in absolute) is the total pressure. PSIG (LB/sq.
gauge) is the pressure compared to atmospheric pressure (14.7psi).
PSIA = PSIG+ Atmospheric pressure.
Saturation: a condition existing when a substance contains the largest quantity
of another substance it can hold for that temperature and pressure.
Condensation: the process whereby vapor changes to a liquid without changingtemperature due to removal of heat (latent) to the surroundings.
Evaporation/vaporization: is the process by which a liquid changes into vapor
by absorbing heat.
Relative humidity: The relationship of the actual humidity in the atmosphere to
the maximum that air could hold at that temperature and pressure.
Enthalpy: the total amount of thermal energy (heat) contained in a fluid. Thisdepends on the fluid nature, pressure and temperature.
Ton of refrigeration: the amount of cooling produced by melting 1 ton of ice
in 24 hours.
Refrigeration Cycle
If we take a liquid refrigerant, confine it in a container and place this
container near a warm object, the liquid will absorb heat from the warm
9
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 10/37
object. If enough heat is absorbed by the liquid refrigerant, it will boil and
vaporize. If the vaporized refrigerant gas is sufficiently compressed, it
will give up the heat that absorbed from the warm object, and the gas will
condense back to a liquid. This process of at alternatively vaporizing and
condensing a refrigerant is called a refrigeration cycle. When the cycle is
accomplished continuously through the use of machinery, it is called
mechanical refrigeration and also called vapour compression cycle.
Vapour Compression Cycle:
The basic components required to make up a refrigeration system are:
1. An evaporator- the cooling coil
2. A pump -the compressor
3. A condenser - the heat disposer
4. A liquid metering device-expansion value or capillary tube.
Evaporator: The refrigeration component known as the cooling coil, chiller and low side of the system. The liquid enters the evaporator tubes or shell, its
pressure drops to the pressure inside the evaporator. The refrigerant passes
through the evaporator coil, it continues to absorb heat from the surrounding
area to be cooled and vaporize. The absorption of heat by the vaporizing
refrigerant produces the cooling.
The refrigerant vapour leaves the evaporator through the suction line and flowsinto the compressor. There it is compressed into a hot, high pressure gas.
The compressor inlet ends the low side of the system.
10
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 11/37
Compressor: The compressor whose function is to draw the refrigerant vapour
from the evaporator suction line and compress it from a low-pressure, low-
temperature gas to a high-pressure, high temperature gas.
The compressor lowers the pressure in the evaporator, making it colder than
surrounding air or water. The refrigerant absorbs heat from the surrounding area
and vaporizes.
At the compressor outlet high-pressure, high temperature gas is discharged into
the condenser. The outlet starts the high side of the system.
11
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 12/37
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 13/37
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 14/37
the conversion of the refrigerant vapour (coming from the evaporator)
into liquid. In the absorption system, the condenser is also used but
compressor is replaced by the combination of the absorber-generator.
The refrigerant used in the absorption system is one whose vapour is
highly soluble in the another liquid or solution called the absorbent. The
absorbent should be nonvolatile. Two containers, one containing the
refrigerant (evaporator) and the other containing the absorbent (absorber)
are interconnected. The refrigerant liquid vaporizes in the evaporator.
Because of the strong affinity of the absorbent for the refrigerant vapour,
the absorbent in the absorber absorbs the vapour formed in the
evaporator, there by reducing the vapour pressure in the evaporator and
allowing the refrigerant liquid to vaporize continuously in the evaporator
to produce refrigeration. The absorbent, which has sucked and dissolved
the refrigerant vapour is sent to the generator. In the generator the
solution (absorbent) is heated by means of hot water or a steam coil (tube
bundle). On getting heat, the solution releases (discharged) the refrigerant
14
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 15/37
vapour which passes into the condenser, where it is condensed by cooling
water/air.
The released solution of the generator is sent back to the absorber, where
it is cooled by means of cooling water/air. The refrigerant liquid from the
condenser enters the evaporator and the cycle is repeated.
Types of absorption system:
1. Ammonia absorption system
Refrigerant-Ammonia, Absorbent-water
2. Lithium-bromide absorption system (very popular)
Refrigerant-water, Absorbent, lithium-bromide.
Relative advantage and disadvantages of two systems.
1. Since heat is the operating force of an absorption system so less electric
power is required for this system.
2. Absorption system uses the cheapest, safest and most available
refrigerant, ordinary tap water. Its absorbent is a simple salt.
3. In the absorption system the absence of heavy moving parts practicallyeliminates vibration and reduces the noise level to a minimum. Less
maintenance is required.
4. For the same capacity larger size cooling tower is required for the
absorption system.
5. Crystallization can occur in the absorption system so that special measure
must be taken in the absorption system to avoid crystallization.6. The absorption machine requires more insulation.
Field of application:
1. Where low cost fuel, natural gas is available, the absorption system is
suitable for use.
2. Where waste steam or hot water is available ,the absorption system will
be economical.
15
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 16/37
3. Absorption machines may be applied also in conjunction with gas
engines or turbines. It can use the steam or hot water made in a waste
system of boiler/gas engine.
4. Where there is a lack of adequate electric facilities for installation a
compression machine. Because absorption machine use only 2-9% of the
electric power required by compression type machine.
1.3 Air conditioning plant hardware
Evaporator: The evaporator is the component that absorbs the unwanted
heat in the of refrigeration system. Evaporator temperature must always be lower than the temperature of the medium to be cooled.
There are two basic types of evaporators:
1. Dry or direct expansion
2. Flooded.
1. Dry or direct expansion evaporator: It has a coil tubing between the
metering device and the compressor. The dry evaporator uses a
16
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 17/37
predetermined amount liquid refrigerant and completely vaporizes the
refrigerant before it reaches the suction line.
These types of evaporator may be sub-divided:
1. Prime surface evaporator (bare type)
2. Plate type: normally found in refrigerators and freezers.
3. Fin-tube type: normally found in window & split type air-
conditioners.
2. Flooded evaporator: A flooded evaporator is completely filled with
liquid refrigerant. In these evaporators secondary refrigerant flows in the
tubes and liquid refrigerant flows in the shell. Since the shell is floodedwith refrigerant, it boils and completely wets the interior walls. The
flooded evaporator system is also known as an indirect system.
Compressors: The compressor takes refrigerant vapour at a low
temperature and raises it to a high temperature and pressure. It pumps
refrigerant throughout the system.
There are three main types of compressors:1. Reciprocating.
2. Centrifugal
3. Rotary
1. Reciprocating compressors: Three types
i) Hermetic compressor (welded): Hermetically sealed, normally
found in window & spit-type units.ii) Semi-hermitic compressor: This is a serviceable hermetic
compressor.
iii) Open-type compressor: In this compressor, one end of the
crankshaft extends through the crankcase and is driven by an
external power source. It may be direct drive or belt drive.
17
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 18/37
2. Centrifugal compressor: In the centrifugal compressor, a high-speed
impeller blade rotates within volute (housing). As the blades rotate rapidly theycause centrifugal force to raise the refrigerant gas pressure within the housing.
The centrifugal compressor normally handles large volumes of gas at low
compression ratio.
3. Rotary Compressor: In the rotary compressor, a vane rotates within a
cylinder. A rotary compressor is a positive-displacement compressor. Two types
are in common use.
18
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 19/37
i) Rotary sliding vane.
ii) Helical rotary screw compressor : Male and female helical rotors are in
the housing with suction and discharge ports. The male rotor is called lobe and
the female rotor is called grove. The suction port is normally at the top of the
compressor and the discharge port at the bottom. Suction enters the compressor
port to the unmeshed rotors. As the rotor turn and start to mesh, they compress
the suction gas. The volume area decreases thus increasing the vapour pressure.
The helical rotary screw compressor becomes popular in large plants because of
its less power consumption and smooth and quiet operation.
Condensers: It is heat rejection equipment. It transfers heat from the
refrigeration system to a medium that can absorb it. The condensing
medium must always be colder than the refrigerant it is condensing.
There are three types of condenser commonly used:
1. Air-cooled condenser
2. Evaporative condenser 3. Water-cooled condenser.
1. Air-cooled condenser : In which heat is rejected directly to the air. Space
is not needed for piping, cooling towers, water pumps. These types of
condensers are most commonly used in relatively small refrigeration system.
Three types of air-cooled condenser:
(i) Natural draft condenser: Ambient air is the condensing medium.(ii) Forced-air condenser: A fan pushes air through the condenser coil.
(iii) Inducted air condenser: A fan draws or pulls the air over the condenser
coil.
3. Evaporative condenser: In which sprayed coils used to dissipate the
heat to the air by sensible and latent heat transfer. Both air and water are
employed as a condensing medium.
19
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 20/37
3. Water-cooled condenser: In which heat is transferred to water. It uses
water as the condensing medium. There are three types water-cooled
condensers.
i) Tube-in-tube or double pipe condenser: A small diameter pipe is
inserted into a bigger diameter pipe. Water flows through the inner tube and the
refrigerant through the annual space between the two tubes. In this system
cleaning is not easy.
ii) Shell-and-coil condenser: It consists of a welded sheet shell containing a
coil of finned tubing in which water flows, the refrigerant being in the shell.
Since the tube bundle is in the form of coil, the waterside of the tube cannot be
brushed but can only be cleaned chemically.
iii) Shell-and-tube condenser: In this condenser refrigerant is in the shell
and water is in the tubes. The water box is bolted to the tubes at each end.
20
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 21/37
Depending on the number of baffles inside the unit, water may pass several
times. This type of condenser is easy to clean waterside, it is very popular.
Pumps:
Centrifugal pumps are mostly used with air conditioning and refrigeration
systems. The centrifugal pump is rated on the basis of capacity i.e. volume of
liquid per unit time (gpm), against a head (feet of water) and the energy
required at a given speed.
Pumps are selected from manufacture’s performance curves. Most
standard pumps are designed to operate at maximum efficiency about
midway on the head-capacity curve. Selecting a pump at the maximum
efficiency point or slightly to the left assists in minimizing problems of
noise and vibration. The suction piping at the centrifugal pump must be
designed with care to avoid possible malfunction.
Air handling units: An equipment consists of cooling and/or heating
coil, a blower or fan with electric motor and air cleaning componentsused for the purpose of cooling/heating and distributing supply air to a
room or area. When a duct system is needed in an air conditioning
application, AHU may be used.
The parameters, which influence the selection of an AHU, are air
quantity, static pressure, sound level, available space and the nature of the
load.Fan coil units: The primary components of a fan-coil unit are a fan to
produce a flow of air and a chilled water or direct expansion coil to cool
and dehumidify the air. FCU units are suitable for using in a multi-room
application where load consumption varies independently and as a
function of time.
21
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 22/37
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 23/37
to the condenser. Make-up water is supplied to the tower, controlled by a float
valve.
Operation and Maintenance:Good operation and maintenance is only possible if all plants and
machinery are properly installed & commissioned. If the plant room is
very much crowded, leaving little space for the servicing or replacing of
components, the service time increases. There should be i) sufficient
space for cleaning/brushing of the condenser and chiller-water tubes (ii)
23
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 24/37
accessibility to clean air-cooled condensers and cooling coils (iii)
sufficient space between the ends of the motor and compressor shaft etc.
Operation:
At the time of operation the following points should be checked &
insured:
Check the power supply (within the rated voltage).
Ensure that guards are provided for all rotating parts.
Check the proper operation of safety controls such as high pressure, low
pressure & oil pressure cut-outs, water flow switches, overload elements of
all motors, the thermostats, etc.
Maintain a record of day-to-day readings of the plant known as log. The log
helps in trouble shooting at a later stage. Some reading are given below.
a) Compressor: Oil level, oil pressure, suction/discharge pressure.
b) Motor: Voltage, current.
c) Condenser: Pressure, Disch. temp, inlet & outlet temp. of water, flow
rate, pressure drop.
d. Cooler: Pressure, suction temp, inlet & outlet temp of water, flow rate,
pressure drop.
e) Pumps (condenser/chilled water): Suction & discharge pressure.
f) Cooling tower: WB approach.
h) AHU: Intel & outlet temp.
Maintenance:All mechanical equipment needs strict maintenance. Proper and timely
periodic check & maintenance can save considerable amount of time,
material & money. The program of regular daily, weekly, monthly checks
and annual maintenance along with checklists shall be made with the help
of manufacturer instruction manual. Preventive maintenance includes the
following:
24
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 25/37
Evaporators/Chillers:
Clean air filters regularly.
Clean/wash the evaporator coil periodically.
Clean strainers and filters in the water system regularly.
Brush water tubes in chillers at least once in a year.
Check and rectify oil return problems etc.
Evaporators/Chillers:
Clean air-cooled condensers regularly with compressed air or an air blower.
Clean/descale condenser water tubes periodically (twice in a year).
Clean strainers in water regularly.
Cooling tower:
Drain and clean the cooling tower tank periodically.
Clean cooling tower water strainers regularly.
Check the spray nozzles and headers for proper operation.
Check fan belts for wear and proper tension.Lubrications of fans shaft, pump and motor bearings etc.
Compressor & Motor:
Check oil filter and oil level regularly .
Compressor bearings should be periodically checked for wear.
Check compressor motor mounting for tightness & vibration
Meg. Motor windings annually to check for deterioration of winding.
etc
AHU & Pump-motor:
Clean air filter regularly once in a fortnight.
Check fan belts for wear and proper tension.
lubrication of fan shaft, pump and motor bearings.
25
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 26/37
Electrical Controls:
All the safety and operating controls should be checked periodically for
proper operation.
1.4 Vibration & Noise
Source of vibration & noise:
In air-conditioning system air handling, pump-motor, blower,
compressor produce noise & vibration.
Motors produce airborne sound and physical vibration. The undesirable
manifestation of sound and vibration is termed noise. Airborne noise is produced by all the vibrating parts of the motor. The initial sources are
magnetic, mechanical and windage.
Magnetic noise is produced by magnetic forces (flux) in the air gap and
other parts of a magnetic circuit. Mechanical noise may result from
misalignment, disrepair, unbalance or bearing disorder.
Windage noise is produced by ventilation air through the motor together with propulsory elements.
Improper coupling between the motor and its support may transmit
unwanted vibration & noise to building structure.
Duct & piping system unless adequately designed, may act as a
significant sound source and will transmit noise through out the building.
Methods of elimination of vibration and noise:
The foundation of the rotating machine should be heavy to reduce vibration
and should be properly aligned & level.
Insulators should be used to absorb the vibrations produced by AHU as well
as other rotating machinery.
Disorder bearings of rotating machinery should be replaced timely and
bearings should be well-lubricated.
26
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 27/37
Canvas tape or asbestos cloth connectors should be used for all duct
connection to fans and air-conditioners to minimize sound transmission.
Insulating/sound absorbing material should also be used to guard against
noise.
Sound traps, duct liner, vibration isolators and duct stiffeners might be
required to damper the generated noise and vibration in certain critical areas.
Relevant BNBC/93 code:
3.3.3.4 Noise Control:
a) Air Ducts: Air ducts shall be so designed and installed to avoid any
transmission of noise and vibration which may be picked up by the duct system
from equipment room or a adjoining rooms. Duct system shall not allow cross
talk or noise transfer from one occupied space to another.
Duct system shall be appropriately designed, constructed and installed to obtain
adequate attention of noise required to maintain recommended noise level in the
air-conditioned space.
Duct construction and installation shall be such that drumming effect of duct
walls and noise transmission through the duct wall can be minimized to
approved level.
b) Plenum Chamber: If required, properly designed plenum chamber, lined
with approved sound absorbed material, and or sound attenuators shall be used
for attenuation of noise.c) Flow Control Devices: Air dampers and other flow control devices shall
be so selected that noise generation do not exceed approved levels.
d) Air terminals: Air terminals shall be selected for the approved noise
generation characteristics.
e) Piping: Velocity of fluids in piping shall be so selected that noise
generation do not exceed approved levels.
27
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 28/37
1.5 Refrigerants
A refrigerant is a fluid in a refrigeration system that picks up heat byevaporating at a low temperature and pressure and gives up heat by condensing
at a higher temperature and pressure.
Desirable Characteristics of refrigerants:
Low-boiling temperature.
High latent heat of vaporization.
Non-flammable, non-explosive, non-toxic.Chemically stable.
Non-corrosive.
Moderate working pressures.
simple detection and location of leak
Non injurious to lubricating oil.
Low freezing temperature.
High critical temperature.
Low cost.
Moderate specific volume of vapour.
Types of refrigerants:
1. CFC(Chlorofluorocarbons): CFC refrigerants contain chlorine, fluorine
and carbon. They reach the ozone layer and deplete it. Most used CFC
refrigerants: R12, R22, R113, R114, R500 and R502
2. HCFC(hydrochlorofluorocarbons): HCFC refrigerants contain
hydrogen, chlorine, fluorine and carbon. HCFC-123 is substitute for R11
and HCFC-124 is possible substitute for CFC-114.
28
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 29/37
3. HFC (hydrofluorocarbons): Which contains hydrogen, fluorine, and
carbon.
All fluorocarbon-based refrigerants are heavier than air. It is believed that
they harm the ozone layer less than CFCs.
Ozone layer depletion and green house effect due to CFCs:
Approximately 20 to 30 miles above sea level is the ozone layer, part of
the earth’s atmosphere. Ozone layer absorbs ultraviolet rays from the sun
and shields the earth from much of the damage caused by ultraviolet rays.
But CFC refrigerants reach the ozone layer and deplete it through a
chemical reaction. Ozone depletion allows ultraviolet rays to enter the
earth’s atmosphere and harm humans, animals and plant life. Ultraviolet
rays also raise the heat of earth’s atmosphere like as green house.
Safe handling of refrigerants:
Refrigerant cylinders should never be heated and cylinders are under
pressure and should be treated with respect.
Non-refillable cylinder should never be refilled.
Do not drop, tamper, or abuse cylinders.
Do not spill liquid refrigerant on the skin.
Gloves, protective clothing, and goggles should be used whenever handling
refrigerants.
Charging refrigerant:
There are two methods for charging refrigeration systems.
i.) Vapour charging
ii.) Liquid charging
i) Vapour charging: Small systems are usually vapour charged
through the gauge port of the compressor suction service valve.
29
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 30/37
ii) Liquid charging: liquid refrigerant is introduced into the system
through the charging port on the downstream side of main liquid
line.
1.6 Ventilation
Requirements :
Introduction of outdoor air for ventilation of conditioned spaces isnecessary to dilute the odors given off by people, smoking and other
internal air contaminants.
Outdoor air normally has a different heat content than the air within the
conditioned space and therefore ventilation air impose a load on the air
conditioning equipment.
Types of ventilation:
i. Natural ventilation
ii. Mechanical ventilation (by mechanical means)
The amount of ventilation air requirement varies primarily with the total
number of people, ceiling height and intensity of smoking.
- 7.5 cfm air per person is recommended for dilution of body odors.
- Minimum 15 to 25 cfm per person when people smoke.
Air change requirements in buildings and establishment.
Ventilation in certain area such as operating room, autopsy room,
delivery room, intensive care unit etc. is very critical. In these area
ventilation system is designed so that it mix and change room air at a
predetermined rate to facilitate removal of order and rodon gas, low level
of airborne bacterial contamination & concentration anesthetic gases.
30
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 31/37
Required air charge requirements are given below as per BNBC/93 code:
3.7.4.2(Table 8.3.6)
Autopsy room 12 air changes/hour.
Delivery rooms, trauma room 15 air changes/hour.
Laboratories room 6 air changes /hour
Operating rooms 20 air changes /hour.
Intensive cave rooms 6 air charges/hour.
1.7 Water heater, Space heater and Geysers, control of temperature,
air and motor flow in these systems.
Space-heater:
Electric heaters that are used to heat air space in the room or area are
called space heaters. They are manufactured in various sizes and types to
suit different conditions of service and heat requirement. Irrespective of
their construction and size, they all work on the electrical resistance
principal; that is, a length of resistance wire becomes heated when an
electric current passes through it.
There are several types of space heaters:
1. Bowl-type heater (radiant)
2. Convection type heater
3. Immersion type heater
4. Forced draft heater.
Bowl type heater has obtained its name from the bowl-like shape of its
metallic reflector. The reflector bowl radiates heat in a cone-shaped wide
beam.
The Convection type heater consists of performed sheet metal cases
through which air can circulates over the heating element surface. The
31
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 32/37
warmed air, through convection, is caused to rise, thereby providing
circulation of warm air in the room. The heating elements consists of
resistance wire wound on cylindrical insulators.
Immersion heaters , often called electric steam radiator, are so designed
that the heating units can be placed directly in the water to be heated.
Immersion heaters may be equipped with thermostats for automatic
temperature control.
Forced draft heater consists of one or more heating elements and an
electric fan, which blows the heated air through the heating units and
circulates it is a given area. This type heaters are available with or without thermostats for room temperature control.
Water Heaters/ Geysers:
There are two types of water heaters:
i) Electric water heater.
ii) Gas fired water heater.
i) Electric water heater: An automatic electric water heater consists of ametal water-storage tank that is heavily insulated to prevent the escape of heat.
One or two electric heating elements, with the necessary thermostatic and safety
controls, are mounted inside the storage tank. The heating coils are shielded
from direct contact with the water with a metal watertight enclosure. The
heating units are immersed in water. All tank seams are welded and are usually
tested with a hydrostatic pressure of approx. 300 psi. The tank capacity mayvary and is directly dependent on the hot water demand.
The heating element is equipped thermostats to control water temperature
automatically. Most thermostats used for water heaters have a range of from
100 0F to 200 0F and they are usually set at the factory to deliver water a constant
temperature at the tank outlet.
32
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 33/37
ii) Gas Water heater: Gas water heaters are those in which the hot water
tank, the gas burner, the combustion chamber and the necessary insulation are
combined in a single unit with provision for an automatic supply of hot water.
Water tank sizes very, depending on their requirement. In this type of heater, the
heat from the gas flame is transmitted to the water by direct conduction through
the tank bottom and flue surfaces. Some heaters have multiple central flues,
while in other designs the hot exhaust gasses pass between the outer surfaces of
the tank and the insulating jacket. The gas waters are usually equipped with
thermostat, thermocouple, pressure-relief valves etc. Thermocouple is used to
ignite the burner and pressure relief valves are used to relieve excessive
pressure in the heating system. Gas water heater is suitable & economical for
using in relatively large water consumption. Initial investment is higher.
33
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 34/37
34
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 35/37
35
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 36/37
36
7/28/2019 AIR CONDITION WITH PICTURES.doc
http://slidepdf.com/reader/full/air-condition-with-picturesdoc 37/37