IMPORTANT WARNINGS
OPERATION
Warning: DO NOT OPERATE THIS EQUIPMENT OVER 200 PSI
Danger: DO NOT ATTEMPT TO REMOVE OR REPAIR ANY PART OF THE SYSTEM UNITIL IT IS COMPLETELY DEPRESURIZED. SERIOUS PERSONAL INJURY OR DEATH MAY RESULT IF THIS RULE IS NOT FOLLOWED
1. Connect an air hose from the air supply to the inlet side of the aftercooler.
2. Connect an air hose from the aftercooler skid outlet to the equipment air inlet.
3. Start the compressor.
4. Slowly open the air inlet ball valve to pressurize the system.
5. Adjust the regulator for the air motor on the Filter-Regulator-Lubricator (FRL) (Instructions next page) to read the working pressure (PSI) on the label. NOTE: On hot days run the air motor at maximum pressure. (see chart next page)
6. Adjust the oil output on the lubricator (Clear Dial) by turning clockwise or counter clock-wise until there is the required drops of oil every minute. (see chart next page)
7. Open the air supply to the equipment. (if ball valve is equipped)
8. Slightly open the ball valve for the moisture separator (black canister) and let it drain while using the unit.
NOTE: COLD WEATHER OPERATION - The fan air motor should be regulated so that the aftercooler temperature gauge reads above 0°C to avoid freezing the core assembly. The aftercooler has a drain installed for cold weather climate areas and should be drained after every use to avoid core damage. Leave the aftercooler drain open when not in use.
Pressure & CFM Requirements for Aftercooler Air Motors
NOTE: Working pressure is at 21°C (70°F) ambient temperature. In warmer weather the air motors can be operated up to or at the maximum pressure.
3 Copyright© 2017 Mod-U-Blast®, All Rights Reserved
Aftercooler Owner’s Manual
SHUT DOWN
Filter Do Not Fill
With Oil
Regulator Pull down on knob to adjust
Push up to lock
Lubricator Fill to Line on Glass With ATF
FRL
1. Close the ball valve on the outlet side of the aftercooler package or at the equipment. (if equipped)
2. Shut down the air supply to the aftercooler package.3. Open the drains for the aftercooler, coalescer and moisture separator.4. After the air is removed, close the air inlet ball valve.5. Leave all the drains open while storing.
Aftercooler Owner’s Manual
4 Copyright© 2017 Mod-U-Blast®, All Rights Reserved
FRL
DIFFERENTIAL PRESSURE GAUGE
AFTERCOOLER
AIR INLET
AIR OUTLET
THERMOMETER
MOISTURE FILTER
COALESCER DRAINS
DSA-250MS-M Shown here
5 Copyright© 2017 Mod-U-Blast®, All Rights Reserved
Aftercooler Owner’s Manual
For Parts Call 1-800-661-3842 and Ask For The Order Desk
Thermometer 20114 1 1 1 1 1
FRL Pressure Gauge 55415 1 1 1 1 1
Air Motor for Aftercooler DAC-AMV4 1 1 1
Air Motor for Aftercooler DAC-AM6 1
Air Motor for Aftercooler DAC-AM16 1
Aftercooler (w/o air motor) DAC-250 1
Aftercooler (w/o air motor) DAC-450 1
Aftercooler (w/o air motor) DAC-750 1
Aftercooler (w/o air motor) DAC-1000 1
Aftercooler (w/o air motor) DAC-1600 1
Coalescer Replacement Element - MUB* DSC-250-DEL 1
Coalescer Replacement Element - MUB* DSC-450-DEL 1
Coalescer Replacement Element - MUB* DSC-750-DEL 1
Coalescer Replacement Element - MUB* DSC-1000-DEL 1
Coalescer Replacement Element - MUB* DSC-1600-DEL 1
Coalescer Differential Pressure Gauge - MUB* DSC-DPG 1 1 1 1 1
Description Stock # DSA250MS-M DSA450MS-M DSA750MS-M DSA1000MS-M DSA1600MS-M QTY QTY QTY QTY QTY
PARTS LIST
Note: These skid units may have been substituted with AKG aftercoolers which will be la-beled. Our regular MUB coalescers are RED in colour all others would be gold or white.Please check the unit to see what is installed before ordering. All units with AKG aftercoolers and non MUB coalescers please contact your Mod-U-Blast sales representative for price and availability.
*MUB - Mod-U-Blast Model (Red)
Aftercooler Owner’s Manual
6 Copyright© 2017 Mod-U-Blast®, All Rights Reserved
Mod-U-Blast equipment is covered by a one (1) year warranty against defects in material and workmanship starting from the purchase date. This covers the equipment as well as all major components.
This warranty does not apply to abnormal use of the equipment or parts. Parts considered consumables are not
covered by warranty.
Claims will be honored only if the warranty card is returned within a period of two (2) months from the factory shipping date.
The card can be returned to your Mod-U-Blast salesperson or mailed to the address below.
In the event of failure of this equipment please contact a Mod-U-Blast service centre
or call (780) 425-5510.
403 - 69 Avenue NWEdmonton, Alberta
CanadaT6P 0C2
PH: (780) 425-5510 FAX: (780) 425-5540
Warranty