    Test Report on LED Tube Lightsupplied by ADEX CORPORATION LIMITED.

    Baitul Abed (3rdFloor), 53 Purana Paltan, Dhaka-1000. Bangladesh

    Subject : Test Report for 8W LED Tube Light

    Rating : 8W, 100-280VEquipment Used to Test the Solar LED Tube Light 4W, 12V DC

    1. Digital Oscilloscope2. High sensitive Digital Multimeter3. Power Supply4. Digital Lumen (lux) Meter5. Variable DC Power Supply6. Light intensity measurement setup

    OBSERVATION

    SymbolTest

    ParameterTest Condition

    Min Typ. Max. TestFindings

    Unit

    Lux Brightness

    Measured at 1 meter

    distance from the source:

    Viewing angle = 0 deg.

    170 182 199

    Lux

    Viewing angle = 30 deg. 150 160 196

    Viewing angle =120 deg. 55 65 153

    PinPower

    Consumption

    At operatingvoltage 85V-

    265V, AC

    85V 8.5 9.0 9.5 8.16

    Watt220V 9.46

    253.8V 9.64

    EfficacyLuminous

    efficacy

    Measure total Lumen and

    Power

    95 100111 Lumen/Watt

    CC

    Constant

    Current of theDriver

    Use resistive load

    and vary the resistor

    value (75-100 Ohm)and measure the

    Load Current

    75 180 200 220 40

    mA85 40

    100 40

    P0No Load

    Power

    No Load at the output of

    the driver

    0.5 0.88 Watt

    Temp.

    Temperature

    rise at the

    Tube Surface

    Measure the body

    temperature of the tube

    after 1 hour of operationand calculate the difference

    from Ambient

    Temperature

    2011 Deg.C

  • 8/13/2019 Adex tube 8w.docx

    2/3

    Test Report on LED Tube Lightsupplied by ADEX CORPORATION LIMITED.

    Baitul Abed (3rdFloor), 53 Purana Paltan, Dhaka-1000. Bangladesh

    Experimental Set-up:

    a

    Figure 1: a) Measurement of Light along yz

    plane (perpendicular to tube axis)

    Tube axis x

    y

    z

    Perpendicular

    to tube axis,that is yz

    plane

    0

    90

    180

    b

    00

    3450

    xy Plane

    150

    44cm

    30

    0

    Tube axis x

    y

    Figure 1: b) Measurement of Light along

    xy plane (parallel to tube axis)

  • 8/13/2019 Adex tube 8w.docx

    3/3

    Test Report on LED Tube Lightsupplied by ADEX CORPORATION LIMITED.

    Baitul Abed (3rdFloor), 53 Purana Paltan, Dhaka-1000. Bangladesh

    Comment: The overall performance of the supplied LED Tube Light is satisfactory.

    Tested by:(Dr. Md. Nurunnabi Mollah)

    Professor

    Department of EEEKUET, Khulna.

    Experimental Data:

    Angle XY Plane YZ Plane

    0 41 56

    15 450 331

    30 804 522

    45 950 774

    60 998 854

    75 1016 950

    901028 987

    105 1010 943

    120 994 860

    135 938 756

    150 784 542

    165 419 340

    180 39 63

    195 34 48

    210 30 45

    225 29 40

    240 30 36

    25532 34

    270 29 27

    285 32 35

    300 31 38

    315 33 43

    330 34 46

    345 36 48

    360 36 50

    (Md. Osman Goni Nayeem)

    Lecturer

    Department of EEEKUET, Khulna.

    .

    Graphical Representation:

    0

    200

    400

    600

    800

    1000

    1200

    0 30

    60

    90

    120

    150

    180

    210

    240

    270

    300

    330

    360

    Inte

    nsity

    (Lux)

    Angle (Degree)

    XY Plane

    0

    200

    400

    600

    800

    1000

    1200

    0 30

    60

    90

    120

    150

    180

    210

    240

    270

    300

    330

    360

    Intensity

    (Lux)

    Angle (Degree)

    YZ Plane