Add-on Profile (AOP) Expansion - Schaedler Yesco Profile (AOP) Expansion 21 ... • Add devices...

10
Add-on Profile (AOP) Expansion 21 More Choices for Integrated EtherNet/IP Devices Addition of Electronic Data Sheet AOPs makes integration of EtherNet/IP devices easier than ever before Use text-based Electronic Data Sheets Add devices directly from RSLogix 5000 design environment Provides configuration, connection information, I/O tags, and configuration screens, other pre-defined tabs

Transcript of Add-on Profile (AOP) Expansion - Schaedler Yesco Profile (AOP) Expansion 21 ... • Add devices...

Add-on Profile (AOP) Expansion

21

More Choices for Integrated EtherNet/IP Devices• Addition of Electronic Data Sheet AOPs makes integration of EtherNet/IP devices easier than

ever before• Use text-based Electronic Data Sheets• Add devices directly from RSLogix 5000 design environment• Provides configuration, connection information, I/O tags, and configuration screens, other

pre-defined tabs

Socket Connections

Scanners

Printers

Socket ConnectionRobots

Non-Windows Based Workstations

Any Standard Ethernet Devices

Connect Even More Devices to Integrated Architecture• Allows Logix connection to non-CIP

devices• Barcode scanners, vision systems,

printers, robots, competitive controllers, databases, and more

• Socket-specific messaging available in RSLogix 5000

• Supported in:– 1756-EWEB and 1768-EWEB– CompactLogix 5370 L1, L2, L3– 1756-EN2x and 1756-EN3TR

More Efficient Communications Extended to Safety I/O

Logix PACs communicate to other EtherNet/IP devices via Unicast• Offers more IT-friendly communication method• Standard I/O in V18• Standard produced/consumed tags in V18• Safety Produced/Consumed tags in V19• Safety I/O in V20Allow communications to span multiple VLANs or subnets• Example application includes interlocking of

remote controllers over plant infrastructure

23

New Profiles Added to RSLogix 5000 V20

24

Kinetix Integrated Drive Motor (Sercos Interface)

Kinetix 350 EtherNet/IP CIP

Motion

Flex I/OEIP w/DLR

Motor ProtectionEtherNet/IP Adaptor

w/ DLR

ArmorStartEIP w/DLR

SLC EtherNet/IP Adaptor

What changes in V21?

(Confidential – For Internal Use Only) C i h © 2010 R k ll A i

25

Extended data around tags & structures – “Meta Data”

High Speed Button Control

Logix & View Shared Tag Definitions

Controller Based High Speed Data Log

InstanceTag.MotorSpeed.@Max

InstanceTag.MotorSpeed.@EU

InstanceTag.MotorSpeed.@Min

Jog MotorJog Motor

A-B Controller Based High Speed Alarm Log

Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 26

1. Programmable Automation Controllers Hardware

2. Programmable Automation Controllers Software

3. Input and Output Enhancements

(Confidential – For Internal Use Only) 27

• Controller Configures Input & Output Modules to define their behavior:– Input module configuration defines when the module “Produces” Output Command data

• For the –IB16IF: any Input Change of State• For the –LSC8XIB8I: any Input Change of State or any Output Window definitions

– Output module configuration defines which Input module to “Listen” to and what combination of parameters, from both the Controller and the Input module, the Output Pts will respond to

• Output module “Hears” parameters required to energize an Output

1756 I/O Enhancement ProjectPeer to Peer I/O Control Concept

When Input criteria is met, Outputs will respond in less than 50uS

Configuration

Configuration

Input Module produces data

“Gate” CmdsOptional Controller Output

(Confidential – For Internal Use Only) Copyright © 2009 Rockwell Automation, Inc. All rights reserved.28

1756 I/O EnhancementFast DC I/O (target late-summer 2012)

• 1756-IB16IF Fast 24vdc Input Module• <25 uS Symmetrical On /Off response time• 10 uS Pulse Capture capability• Per Point CIPSynch Timestamping • Sink / Source Capable (Isolated)• Event Tags / 2nd Connection support• Uses Peer to Peer I/O Connection to the –OB16IEF for Output control

• 1756-LSC8xIB8I 24vdc Low-Speed Counter• 8 – 40kHz Counters w/Rollover and Preset values in Output Tags• Returns Accum Count + Instantaneous and Average Frequency Values• 8 “Control” Inputs for Up/Dn, Reset and Gate functions• 2 Configurable Output Windows per Counter• Uses Peer to Peer I/O Connection to the –OB16IEF for Output control

• 1756-OB16IEF Fast 24vdc Output• <25 uS Symmetrical On /Off response time• 2A Capability @ 30deg C• Per point E-Fusing (Thermal)• Programmable Fault State Delays• Built-in Pulse Width Modulation • Master to both the –IB16IF Input and the –LSC8XIB8I Counter modules

• 1756-OB16IEFS Scheduled Output• Per Point Scheduling for all 16 outputs

• 32 Schedules• 2 Schedule / Output (On and Off)

• 2A Capability @ 30deg C• Per point E-Fusing (Thermal)• Programmable Fault State Delays• Built-in Pulse Width Modulation greatly simplifies Stitching applications

World class, highest performance IO platform available only from Rockwell AutomationPeer to Peer Control capabilities resulting in Screw to Screw performance <100uS

Peer Device Peer Device

Peer Device

Copyright © 2011 Rockwell Automation, Inc. All rights reserved. 29

1. Programmable Automation Controllers Hardware

2. Programmable Automation Controllers Software

3. Input and Output Enhancements

4. Human-Machine Interface Hardware

PanelView 5300

PanelView 5500Studio

5000

Industrial Computers and Monitors

PanelView Plus Compact

PanelView Plus 6

FactoryTalk View ME

FactoryTalk ViewPoint

FactoryTalk View SE

Visualization Solutions

Becomes PVP 6 Compact CY 2013