ACC ? Detector PVSS II Ethernet Database(s) OPC client DIM client 14448 High VoltageLow Voltage User...

7
ACC ACC ? Detector PVSS II PVSS II Ethernet Database(s) OPC client DIM client 144 48 High Voltage Low Voltage User interface PVSS II LV PMD Control room (ACR) [FSM?] Crate Control On-detector electronics 32 Temp. Monitor VME (wiener?) 1 15/03/06 Detector 12 156 Crocus (on-detector crates) UX-C05/06 CR3 CR4-X03 UX-C05/06 SY1527 (A1821N) CAEN OPCserver EASY 3000 PVSS II OPC client E HV LV 48V PS C LV (48V) 1 2 6 6 1 CR3 PCI-CAN Wiener OPCserver PVSS II OPC client C CR3 PCI-CAN ELMB OPCserver PVSS II OPC client C 1 ELMB 2 DDL CR3 SG2 CR5 SG2 Gas system PLC Gas E Detector PVSS II DIP [GWG] Gas Gas PVSS UX-C CR3 Cooling Plant PLC Detector Cooling E Detector PVSS II Modbus/TCP 1 [TS/CV] TS/CV SCADA

Transcript of ACC ? Detector PVSS II Ethernet Database(s) OPC client DIM client 14448 High VoltageLow Voltage User...

Page 1: ACC ? Detector PVSS II Ethernet Database(s) OPC client DIM client 14448 High VoltageLow Voltage User interface PVSS II LV PMD Control room (ACR) [FSM?]

ACC ACC

?

Detector

PVSS II PVSS II

Ethernet

Database(s)

OPCclient

DIMclient

14448

High Voltage Low Voltage

User interface

PVSS II

LV

PMDC

on

tro

l ro

om

(A

CR

)[FSM?]

Crate Control

On-detectorelectronics

32

Temp. Monitor

VME(wiener?)

1

15/03/06

Detector

12

156

Crocus(on-detector crates)

UX-C05/06

CR3

CR4-X03

UX-C05/06

SY1527(A1821N)

CAEN OPCserver

EASY 3000

PVSS IIOPC client

E

HV

LV

48V PSCLV (48V)

1

2

6

6

1

CR3

PCI-CAN

Wiener OPCserver

PVSS IIOPC client

C

CR3

PCI-CAN

ELMB OPCserver

PVSS IIOPC client

C

1

ELMB

2

DDL

CR3

SG2

CR5

SG2

Gas system

PLC

Gas

E

Detector

PVSS IIDIP

[GWG]

Gas

GasPVSS

UX-C

CR3

CoolingPlant

PLC

Detector Cooling

E

Detector

PVSS IIModbus/TCP

1

[TS/CV]

TS/CVSCADA

Page 2: ACC ? Detector PVSS II Ethernet Database(s) OPC client DIM client 14448 High VoltageLow Voltage User interface PVSS II LV PMD Control room (ACR) [FSM?]

PMDDCS

SMI Control Unit

SMI Device Unit

VETOPRE

HVPSUM24 48

UM 0 23

LVPS

2.5 -2.5HV

3.3

Detector oriented hierarchy

CrateCtrl

Temp

Hardware Device

Infra

Page 3: ACC ? Detector PVSS II Ethernet Database(s) OPC client DIM client 14448 High VoltageLow Voltage User interface PVSS II LV PMD Control room (ACR) [FSM?]

Present Standard State diagram for the DCS

Due to the increasing number of integrated sub-systems in the ALICE DCS, in order to allow a complete integration the present sub-detector DCS state diagram may change.

GO_STANDBYCONFIGURE (run_mode)CALIBRATE (calib_mode) GO_BEAM_TUNGO_READY

MOVING_BEAM_TUN

MOVING_STBY_CONF

MOVING_READY

MOVING_BEAM_TUN

CONFIGURE (run_mode)CALIBRATE (calib_mode)GO_STBY_CONFGO_READY

GO_STBY_CONFGO_BEAM_TUNCALIBRATE (calib_mode)CONFIGURE (run_mode)LOCK

OFF

DOWNLOADING

GO_OFFCONFIGURE (run_mode)GO_STANDBY

CALIBRATING

CALIBRATING

READY

DOWNLOADING

READY_LOCKED

UNLOCK

STBY_CONFIGURED

STANDBY

BEAM_TUNING

CALIBRATINGDOWNLOADING

STOP

STOP

STOP

Page 4: ACC ? Detector PVSS II Ethernet Database(s) OPC client DIM client 14448 High VoltageLow Voltage User interface PVSS II LV PMD Control room (ACR) [FSM?]

Need Of LVDB

• Without LV Distribution, if the LV trips all 6 chains on the module consisting 4608 cells will be off.

• LV segmentation will help in isolating the faulty chains by tripping LV supply for the particular chain if fault persists.Also fault can be monitored remotely and can be use for data analysis.

• Prevents FEE boards from going bad due to excess current drawn by the chips due to HV sparks.

Page 5: ACC ? Detector PVSS II Ethernet Database(s) OPC client DIM client 14448 High VoltageLow Voltage User interface PVSS II LV PMD Control room (ACR) [FSM?]

General description of LVDB

• LVDB helps us in actively distributing the LV-supply among the FEE board chains (12 FEE Boards per chain).

• It also controls the over-current in a chain which may be caused by HV spikes or board going bad. Current limit can be adjust for the different no of FEE boards in a chain.

• One board can supply 6 chains and also through DCS, chains can be monitored and we can have off time of chain in database.

Page 6: ACC ? Detector PVSS II Ethernet Database(s) OPC client DIM client 14448 High VoltageLow Voltage User interface PVSS II LV PMD Control room (ACR) [FSM?]

Low Voltage Distribution Box (LVDB)

To translator Supply

Current adjustment pot

Sensing points to DCS

Power I\P from LV Supply

Page 7: ACC ? Detector PVSS II Ethernet Database(s) OPC client DIM client 14448 High VoltageLow Voltage User interface PVSS II LV PMD Control room (ACR) [FSM?]

Remaining work

• LV no work done till now

• FSM’s need to be finalized

• Configuration dB

• Testing and finalization of LVDB

• Use of ALICE GUI