A7 Selection tables€¦ · SUCOnet p ® (Klöckner-Möller), Modulink P (Weidmüller) MODBUS...

4
1078 ÖLFLEX ® ACCESSORIES FLEXIMARK ® SILVYN ® SKINTOP ® EPIC ® HITRONIC ® ETHERLINE ® UNITRONIC ® APPENDIX For current information see: www.lappgroup.com A7 Selection tables UNITRONIC ® BUS and ETHERLINE ® – which cable suits which fieldbus system? Legend Trademarks 7-W = 7-wire braided conductor AS-I = AS-INTERFACE COMBI IBS = Installation bus cable for INTERBUS DN = Device Net EIB = European Installation Bus FD = Cable suitable for drag chains FRNC = Flame Retardant Non Corrosive G = Rubber outer sheath (EPDM) H = Halogen-free material IBS = Remote bus cable for INTERBUS L2 = Abbr. for SINEC L2-DP LD = Long distance P = Polyurethane outer sheath PB = PROFI BUS PE = Polyethylene outer sheath PROFIBUS-DP = Decentralised Periphery PROFIBUS-FMS = Fieldbus Message Specification PROFIBUS-PA = Process Automation TPE = Thermoplastic elastomer Yv = Cable for routing outdoors/underground with reinforced PVC outer sheath YY = Twin PVC outer sheath CC-Link ® = is a registered trademark of CLPA, Japan DeviceNet TM = is a registered trademark of Open Device Vendors Association (ODVA) Foundation TM = is a registered trademark of Foundation Fieldbus INTERBUS ® = is a registered trademark of Phoenix Contact GmbH & Co. Modulink ® P = is a registered trademark of Weidmüller GmbH & Co. SIMATIC ® = is a registered trademark of SIEMENS AG SINEC ® = is a registered trademark of SIEMENS AG SUCOnet P ® = is a registered trademark of Klöckner + Moeller GmbH VariNet ® -P = is a registered trademark of Pepperl + Fuchs GmbH Usage criteria Cable designation Page 379 381 381 381 380 326 332 332 332 360 342 348 349 346 338 332 332 332 360 344 340 363 363 365 335 375 331 364 327 339 UNITRONIC ® BUS IBS A UNITRONIC ® BUS IBS P COMBI A UNITRONIC ® BUS IBS FD P UNITRONIC ® BUS IBS FD P COMBI UNITRONIC ® BUS IBS Yv COMBI UNITRONIC ® BUS LD A + BUS LD FD P A UNITRONIC ® BUS PB A UNITRONIC ® BUS PB PE UNITRONIC ® BUS PB 7-W A UNITRONIC ® BUS PA UNITRONIC ® BUS PB FD P UNITRONIC ® BUS PB TORSION UNITRONIC ® BUS PB FESTOON UNITRONIC ® BUS PB FD P HYBRID UNITRONIC ® BUS PB Yv, PB YY UNITRONIC ® BUS PB PE FC UNITRONIC ® BUS PB H FC UNITRONIC ® BUS PB P FC UNITRONIC ® BUS PA FC UNITRONIC ® BUS PB FD P FC UNITRONIC ® BUS PB BURIAL FC UNITRONIC ® BUS CAN UNITRONIC ® BUS CAN FD P UNITRONIC ® BUS CAN BURIAL UNITRONIC ® BUS PB HEAT 180 UNITRONIC ® BUS IS UNITRONIC ® BUS PB TRAY UNITRONIC ® BUS CAN TRAY Standards UL/CSA-approved Installation Fixed installation Flexible Highly flexible (drag chains etc.) Suitable for outdoor use/direct burial, UV-resistant Mean characteristic Impedance 100–120 ohms 150 ohms Dimensions In mm 2 , or diameter in mm, or AWG size 3 x 2 x 0.22 3 x 2 x 0.25 3 x 2 x 0.25 + 3 x 1.0 3 x 2 x 0.22 + 3 x 1.0 1 x 2 x 0.22/2 x 2 x 0.22/3 x 2 x 0.22 1 x 2 x 0.64 1 x 2 x 1.0 1 x 2 x 0.8 1 x 2 x 0.64 + 4 x 1.5 1 x 2 x 0.25/2 x 2 x 0.25 1 x 2 x 0.34/2 x 2 x 0.34 1 x 2 x 0.5/2 x 2 x 0.5 1 x 2 x 0.75/2 x 2 x 0.75 2 x 6 + 2 x 2.5 + 1 x 4 x 0.5 Bus systems INTERBUS ® DIN 19258 EN 50251 sensor/actuator bus INTERBUS ® (Phoenix Contact) SUCOnet p ® (Klöckner-Möller), Modulink ® P (Weidmüller) MODBUS VariNet ® -P (Pepperl + Fuchs) PROFIBUS-DP, -FMS, FIP PROFIBUS-PA, Foundation TM Fieldbus CAN ISO 11898, CAN open AS-INTERFACE EIB CC-Link ® Device Net TM (Allen-Bradley/Rockwell Automation) Industrial Ethernet/Fast Ethernet ISOBUS (ISO 11783-2)

Transcript of A7 Selection tables€¦ · SUCOnet p ® (Klöckner-Möller), Modulink P (Weidmüller) MODBUS...

  • 1078

    ÖLF

    LEX®

    ACC

    ESSO

    RIES

    FLEX

    IMAR

    K®SI

    LVYN

    ®SK

    INTO

    P®EP

    IC®

    HIT

    RON

    IC®

    ETH

    ERLI

    NE®

    UN

    ITRO

    NIC

    ®AP

    PEN

    DIX

    For current information see: www.lappgroup.com

    A7 Selection tablesUNITRONIC® BUS and ETHERLINE® – which cable suits which fieldbus system?

    Legend Trademarks7-W = 7-wire braided conductorAS-I = AS-INTERFACECOMBI IBS = Installation bus cable for INTERBUSDN = Device NetEIB = European Installation BusFD = Cable suitable for drag chainsFRNC = Flame Retardant Non CorrosiveG = Rubber outer sheath (EPDM)H = Halogen-free materialIBS = Remote bus cable for INTERBUSL2 = Abbr. for SINEC L2-DP

    LD = Long distanceP = Polyurethane outer sheathPB = PROFI BUSPE = Polyethylene outer sheathPROFIBUS-DP = Decentralised PeripheryPROFIBUS-FMS = Fieldbus Message SpecificationPROFIBUS-PA = Process AutomationTPE = Thermoplastic elastomerYv = Cable for routing outdoors/underground with reinforced PVC outer sheathYY = Twin PVC outer sheath

    CC-Link® = is a registered trademark of CLPA, JapanDeviceNetTM = is a registered trademark of Open Device Vendors Association (ODVA)FoundationTM = is a registered trademark of Foundation FieldbusINTERBUS® = is a registered trademark of Phoenix Contact GmbH & Co.Modulink® P = is a registered trademark of Weidmüller GmbH & Co.SIMATIC® = is a registered trademark of SIEMENS AGSINEC® = is a registered trademark of SIEMENS AGSUCOnet P® = is a registered trademark of Klöckner + Moeller GmbHVariNet®-P = is a registered trademark of Pepperl + Fuchs GmbH

    Usage criteria Cable designationPage 379 381 381 381 380 326 332 332 332 360 342 348 349 346 338 332 332 332 360 344 340 363 363 365 335 375 331 364

    327 339

    UN

    ITRO

    NIC

    ® B

    US

    IBS

    A

    UN

    ITRO

    NIC

    ® B

    US

    IBS

    P C

    OM

    BI A

    UN

    ITRO

    NIC

    ® B

    US

    IBS

    FD P

    UN

    ITRO

    NIC

    ® B

    US

    IBS

    FD P

    CO

    MBI

    UN

    ITRO

    NIC

    ® B

    US

    IBS

    Yv C

    OM

    BI

    UN

    ITRO

    NIC

    ® B

    US

    LD A

    + B

    US

    LD F

    D P

    A

    UN

    ITRO

    NIC

    ® B

    US

    PB A

    UN

    ITRO

    NIC

    ® B

    US

    PB P

    E

    UN

    ITRO

    NIC

    ® B

    US

    PB 7

    -W A

    UN

    ITRO

    NIC

    ® B

    US

    PA

    UN

    ITRO

    NIC

    ® B

    US

    PB F

    D P

    UN

    ITRO

    NIC

    ® B

    US

    PB T

    ORS

    ION

    UN

    ITRO

    NIC

    ® B

    US

    PB F

    ESTO

    ON

    UN

    ITRO

    NIC

    ® B

    US

    PB F

    D P

    HYB

    RID

    UN

    ITRO

    NIC

    ® B

    US

    PB Y

    v, P

    B YY

    UN

    ITRO

    NIC

    ® B

    US

    PB P

    E FC

    UN

    ITRO

    NIC

    ® B

    US

    PB H

    FC

    UN

    ITRO

    NIC

    ® B

    US

    PB P

    FC

    UN

    ITRO

    NIC

    ® B

    US

    PA F

    C

    UN

    ITRO

    NIC

    ® B

    US

    PB F

    D P

    FC

    UN

    ITRO

    NIC

    ® B

    US

    PB B

    URI

    AL F

    C

    UN

    ITRO

    NIC

    ® B

    US

    CAN

    UN

    ITRO

    NIC

    ® B

    US

    CAN

    FD

    P

    UN

    ITRO

    NIC

    ® B

    US

    CAN

    BU

    RIAL

    UN

    ITRO

    NIC

    ® B

    US

    PB H

    EAT

    180

    UN

    ITRO

    NIC

    ® B

    US

    IS

    UN

    ITRO

    NIC

    ® B

    US

    PB T

    RAY

    UN

    ITRO

    NIC

    ® B

    US

    CAN

    TRA

    Y

    Standards

    UL/CSA-approved

    Installation

    Fixed installation

    Flexible

    Highly flexible (drag chains etc.)

    Suitable for outdoor use/direct burial, UV-resistant

    Mean characteristic Impedance

    100–120 ohms

    150 ohms

    Dimensions

    In mm2, or diameter in mm, or AWG size

    3 x 2 x 0.22

    3 x 2 x 0.25

    3 x 2 x 0.25 + 3 x 1.0

    3 x 2 x 0.22 + 3 x 1.0

    1 x 2 x 0.22/2 x 2 x 0.22/3 x 2 x 0.22

    1 x 2 x 0.64

    1 x 2 x 1.0

    1 x 2 x 0.8

    1 x 2 x 0.64 + 4 x 1.5

    1 x 2 x 0.25/2 x 2 x 0.25

    1 x 2 x 0.34/2 x 2 x 0.34

    1 x 2 x 0.5/2 x 2 x 0.5

    1 x 2 x 0.75/2 x 2 x 0.75

    2 x 6 + 2 x 2.5 + 1 x 4 x 0.5

    Bus systems

    INTERBUS® DIN 19258 EN 50251 sensor/actuator bus

    INTERBUS® (Phoenix Contact)

    SUCOnet p® (Klöckner-Möller), Modulink® P (Weidmüller) MODBUSVariNet®-P (Pepperl + Fuchs)

    PROFIBUS-DP, -FMS, FIP

    PROFIBUS-PA, FoundationTM Fieldbus

    CAN ISO 11898, CAN open

    AS-INTERFACE

    EIB

    CC-Link®

    Device NetTM (Allen-Bradley/Rockwell Automation)

    Industrial Ethernet/Fast Ethernet

    ISOBUS (ISO 11783-2)

  • 1079

    ÖLF

    LEX®

    ACC

    ESSO

    RIES

    FLEX

    IMAR

    K®SI

    LVYN

    ®SK

    INTO

    P®EP

    IC®

    HIT

    RON

    IC®

    ETH

    ERLI

    NE®

    UN

    ITRO

    NIC

    ®AP

    PEN

    DIX

    For current information see: www.lappgroup.com

    Selection tables A7UNITRONIC® BUS and ETHERLINE® – which cable suits which fieldbus system?

    Usage criteria Cable designationPage 328 329 329 329 328 361 361 361 361 362 362 362 362 382 382 376 376 377 377 417 417 418 429 420 435 430 438 434 436 425 445 444 419 417 429 449

    420

    UN

    ITRO

    NIC

    ® B

    US

    ASI (

    G)

    UN

    ITRO

    NIC

    ® B

    US

    ASI L

    D F

    D P

    UN

    ITRO

    NIC

    ® B

    US

    ASI F

    D (T

    PE) A

    U

    NIT

    RON

    IC® B

    US

    ASI F

    D P

    FRN

    CU

    NIT

    RON

    IC® B

    US

    ASI (

    PVC

    ) AU

    NIT

    RON

    IC® B

    US

    DN

    TH

    ICK

    FRN

    CU

    NIT

    RON

    IC® B

    US

    DN

    TH

    IN F

    RNC

    UN

    ITRO

    NIC

    ® B

    US

    DN

    TH

    ICK

    YU

    NIT

    RON

    IC® B

    US

    DN

    TH

    IN Y

    UN

    ITRO

    NIC

    ® B

    US

    DN

    TH

    ICK

    FD P

    UN

    ITRO

    NIC

    ® B

    US

    DN

    TH

    IN F

    D P

    UN

    ITRO

    NIC

    ® B

    US

    DN

    TH

    ICK

    FD Y

    UN

    ITRO

    NIC

    ® B

    US

    DN

    TH

    IN F

    D Y

    UN

    ITRO

    NIC

    ® B

    US

    EIB,

    BU

    S EI

    B H

    UN

    ITRO

    NIC

    ® B

    US

    EIB

    CO

    MBI

    UN

    ITRO

    NIC

    ® B

    US

    FF 3

    , FF

    3 AR

    MU

    NIT

    RON

    IC® B

    US

    FF 2

    UN

    ITRO

    NIC

    ® B

    US

    CC

    UN

    ITRO

    NIC

    ® B

    US

    CC

    FD

    P F

    RNC

    ETH

    ERLI

    NE®

    H, P

    ETH

    ERLI

    NE®

    H-H

    ETH

    ERLI

    NE®

    H F

    LEX,

    P-F

    LEX

    ETH

    ERLI

    NE®

    PN

    Cat

    .5ET

    HER

    LIN

    E® F

    D C

    at.5

    ETH

    ERLI

    NE®

    PN

    Cat

    .5 F

    DET

    HER

    LIN

    E® P

    N F

    LEX

    Cat

    .5ET

    HER

    LIN

    E® C

    at.5

    ARM

    ETH

    ERLI

    NE®

    Cat

    .5 F

    RNC

    HYB

    RID

    ETH

    ERLI

    NE®

    Cat

    .6A

    ETH

    ERLI

    NE®

    Cat

    .7ET

    HER

    LIN

    E® T

    ORS

    ION

    Cat

    .5ET

    HER

    LIN

    E® F

    D P

    Cat

    .6ET

    HER

    LIN

    E® T

    ORS

    ION

    Cat

    .6A

    ETH

    ERLI

    NE®

    FD

    Cat

    .6A

    ETH

    ERLI

    NE®

    PN

    Cat

    .6A FL

    EXET

    HER

    LIN

    E® E

    C F

    LEX/

    FD C

    at.5

    eET

    HER

    LIN

    E® Y

    FLE

    X C

    at.5

    eET

    HER

    LIN

    E® T

    RAY

    ER P

    N Y

    FC

    ETH

    ERLI

    NE®

    TO

    RSIO

    N C

    at.7

    Standards

    UL/CSA-approved

    Installation

    Fixed installationFlexibleHighly flexible (drag chains, torsional stress etc.)Suitable for outdoor use/direct burial, UV-resistant

    Mean characteristic Impedance

    100–120 ohms

    Dimensions

    In mm2, or diameter in mm, or AWG size1 x 2 x 0.5, 2 x 2 x 0.52 x 1.52 x 2.5AWG 18 + 15AWG 24 + 222 x 2 x 0.82 x 2 x 0.8 + 3 x 1.52 x 2 x AWG 24/1 and 4 x 2 x AWG 24/14 x 2 x AWG 24/14 x 2 x AWG 24/72 x 2 x AWG 26/7 and 4 x 2 x AWG 26/74 x 2 x AWG 26/72 x 2 x AWG 22/12 x 2 x AWG 26/19, 4 x 2 x AWG 26/192 x 2 x AWG 22/72 x 2 x AWG 22/191 x 2 x 1.1 + 1 x 1.11 x 2 x 1.13 x 1 x AWG 204 x 2 x AWG 22/14 x 2 x AWG 22/74 x 2 x AWG 23/72 x 2 x AWG 22/7 + 4 x 1.54 x 2 x AWG 26/19

    Bus systems

    INTERBUS® DIN 19258 EN 50251 sensor/actuator busINTERBUS® (Phoenix Contact)SUCOnet p® (Klöckner-Möller), Modulink® P (Weidmüller) MODBUS VariNet®-P (Pepperl + Fuchs)PROFIBUS DIN 19245 EN 50170PROFIBUS-DP, -FMS, FIPPROFIBUS-PA, FoundationTM FieldbusCAN ISO 11898, CAN openAS-INTERFACEEIBCC-Link®

    Device NetTM (Allen-Bradley/Rockwell Automation)Industrial Ethernet/Fast EthernetPROFINETEtherCAT

    Legend Trademarks7-W = 7-wire braided conductorAS-I = AS-INTERFACECOMBI IBS = Installation bus cable for INTERBUSDN = Device NetEIB = European Installation BusFD = Cable suitable for drag chainsFRNC = Flame Retardant Non CorrosiveG = Rubber outer sheath (EPDM)H = Halogen-free materialIBS = Remote bus cable for INTERBUSL2 = Abbr. for SINEC L2-DP

    LD = Long distanceP = Polyurethane outer sheathPB = PROFI BUSPE = Polyethylene outer sheathPROFIBUS-DP = Decentralised PeripheryPROFIBUS-FMS = Fieldbus Message SpecificationPROFIBUS-PA = Process AutomationTPE = Thermoplastic elastomerYv = Cable for routing outdoors/underground with reinforced PVC outer sheathYY = Twin PVC outer sheath

    CC-Link® = is a registered trademark of CLPA, JapanDeviceNetTM = is a registered trademark of Open Device Vendors Association (ODVA)FoundationTM = is a registered trademark of Foundation FieldbusINTERBUS® = is a registered trademark of Phoenix Contact GmbH & Co.Modulink® P = is a registered trademark of Weidmüller GmbH & Co.SIMATIC® = is a registered trademark of SIEMENS AGSINEC® = is a registered trademark of SIEMENS AGSUCOnet P® = is a registered trademark of Klöckner + Moeller GmbHVariNet®-P = is a registered trademark of Pepperl + Fuchs GmbH

  • 1080

    ÖLF

    LEX®

    ACC

    ESSO

    RIES

    FLEX

    IMAR

    K®SI

    LVYN

    ®SK

    INTO

    P®EP

    IC®

    HIT

    RON

    IC®

    ETH

    ERLI

    NE®

    UN

    ITRO

    NIC

    ®AP

    PEN

    DIX

    For current information see: www.lappgroup.com

    A7 Selection tablesUNITRONIC® BUS and ETHERLINE® – technical data

    ** without FC = 65 mm/FC = 120 mm

    Usage criteria Cable designationPage 379 381 380 326 327 332 342 338 360 363 363 376 376 364 331

    344

    UN

    ITRO

    NIC

    ® B

    US

    IBS

    fixed

    inst

    alla

    tion

    UN

    ITRO

    NIC

    ® B

    US

    IBS

    FD P

    high

    ly fl

    exib

    le a

    pplic

    atio

    n

    UN

    ITRO

    NIC

    ® B

    US

    IBS

    Yvsu

    itabl

    e fo

    r ou

    tdoo

    r us

    e/di

    rect

    bur

    ial

    UN

    ITRO

    NIC

    ® B

    US

    LDfix

    ed in

    stal

    latio

    n

    UN

    ITRO

    NIC

    ® B

    US

    LD F

    D P

    high

    ly fl

    exib

    le a

    pplic

    atio

    n

    UN

    ITRO

    NIC

    ® B

    US

    PBfix

    ed in

    stal

    latio

    n

    UN

    ITRO

    NIC

    ® B

    US

    PB F

    D P

    + P

    B FD

    P F

    Chi

    ghly

    flex

    ible

    app

    licat

    ion

    UN

    ITRO

    NIC

    ® B

    US

    PB Y

    vsu

    itabl

    e fo

    r ou

    tdoo

    r us

    e/di

    rect

    bur

    ial

    UN

    ITRO

    NIC

    ® B

    US

    PA (B

    U +

    BK)

    fixed

    inst

    alla

    tion

    UN

    ITRO

    NIC

    ® B

    US

    CAN

    fixed

    inst

    alla

    tion

    (0.2

    2 m

    m2 )

    UN

    ITRO

    NIC

    ® B

    US

    FD P

    CAN

    FD

    Phi

    ghly

    flex

    ible

    app

    licat

    ion

    (0.2

    5 m

    m2 )

    UN

    ITRO

    NIC

    ® B

    US

    FF 3

    ARM

    fixed

    inst

    alla

    tion

    UN

    ITRO

    NIC

    ® B

    US

    FF 2

    fixed

    inst

    alla

    tion

    UN

    ITRO

    NIC

    ® B

    US

    CAN

    TRA

    Y

    UN

    ITRO

    NIC

    ® B

    US

    PB T

    RAY

    Parameter

    Characteristic impedance Ω 100 100 100 100–120100–120

    150 +/-15

    150 +/-15

    150 +/-15

    100 +/-20 120 120 100 100 120

    150 +/-15

    Mutual capacitance (800 Hz) max. nF/km 60 60 60 60 60 30 30 30 52 40 40 56 65 40 30

    Peak operating voltage V (not for power applications)

    250 250 250 250 250 250 250 250 250 250 250 300 300 250 250

    Test voltage, core/core, Ueff V 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 1500 2000 2000

    Conductor resistance (loop) Data network cable pair max. Ω/km

    186 159.8 186 186 159.8 110 145, 133 115 44 186 159.8 ≤ 24 ≤ 24 110.8 110

    Minimum bending radius, fixed installation 8 x D – 8 x D 8 x D – 75 mm – 75 mm 65 mm 8 x D – 15 x D 15 x D 8 x D 8 x D

    Minimum bending radius, flexing – 15 x D – – 15 x D – ** – – – 15 x D – – – –

    Temperature range from °Cfixed installation to °C

    - 30 + 80

    - 40 + 80

    - 40 + 70

    - 40 + 80

    - 40 + 80

    - 40 + 80

    - 40 + 80

    - 40 + 80

    - 30 + 80

    - 30 + 80

    - 40 + 80

    - 25 + 80

    - 25 + 105

    - 40 + 80

    - 40 + 80

    Temperature range from °Cflexing to °C –

    - 30 + 70 –

    - 5 + 70

    - 30 + 70 –

    - 30 + 70 – –

    - 5 + 70

    - 30 + 70 – –

    - 10 + 70

    - 10 + 70

    Usage criteria Cable designationPage 377 377 417 417 417 418 418 418 419 419 422 430 430 436

    UN

    ITRO

    NIC

    ® B

    US

    CC

    UN

    ITRO

    NIC

    ® B

    US

    CC

    FD

    P F

    RNC

    ETH

    ERLI

    NE®

    H C

    at.5

    e

    ETH

    ERLI

    NE®

    P C

    at.5

    e

    ETH

    ERLI

    NE®

    H-H

    Cat

    .5e

    ETH

    ERLI

    NE®

    H F

    LEX

    Cat

    .5e

    ETH

    ERLI

    NE®

    P F

    LEX

    Cat

    .5e

    ETH

    ERLI

    NE®

    Y F

    LEX

    Cat

    .5e

    ETH

    ERLI

    NE®

    Y E

    C F

    LEX

    Cat

    .5e

    ETH

    ERLI

    NE®

    P E

    C F

    LEX

    Cat

    .5e

    ETH

    ERLI

    NE®

    P E

    C F

    D C

    at.5

    e

    ETH

    ERLI

    NE®

    PN

    Cat

    .5 Y

    FLE

    X FC

    ETH

    ERLI

    NE®

    PN

    Cat

    .5 F

    RNC

    FLE

    X FC

    ETH

    ERLI

    NE®

    TO

    RSIO

    N C

    at.5

    Parameter

    Characteristic impedance Ω 110 110 100 100 100 100 100 100 100 100 100 100 100 100

    Mutual capacitance (800 Hz) max. nF/km 60 60 48 46 46 48 48 – – – – – – –

    Peak operating voltage V (not for power applications)

    300 300 125 125 125 125 125 125 100 100 100 125 125 100

    Test voltage, core/core, Ueff V 2000 2000 1000 1000 1000 1000 1000 1000 1000 1000 1000 2000 2000 700

    Conductor resistance (loop) Data network cable pair max. Ω/km

    37.8 37.8 192 186.6 186.6 284 284 – – – – – – –

    Minimum bending radius, fixed installation 15 x D 4 x D 7.5-8 x D 7.5-8 x D 8 x D 8 x D 8 x D 8 x D 4 x D 4 x D 4 x D 10 x D 4 x D 5 x D

    Minimum bending radius, flexing – 8 x D – – – 15 x D 15 x D 15 x D 8 x D 8 x D 8 x D 15 x D 8 x D 5 x D

    Temperature range from °Cfixed installation to °C

    - 40 + 70

    - 40 + 80

    - 30 + 80

    - 30 + 80

    - 30 + 80

    - 30 + 80

    - 30 + 80

    - 40 + 80

    - 30 + 80

    - 40 + 80

    - 40 + 80

    - 40 + 80

    - 25 + 80

    - 40 + 80

    Temperature range from °Cflexing to °C –

    - 40 + 80

    - 5 + 60

    - 5 + 60

    - 5 + 60

    - 5 + 60

    - 5 + 60

    - 10 + 70

    - 5 + 50

    - 30 + 50

    - 30 + 50

    - 20 + 60

    - 25 + 80

    - 40 + 80

  • 1081

    ÖLF

    LEX®

    ACC

    ESSO

    RIES

    FLEX

    IMAR

    K®SI

    LVYN

    ®SK

    INTO

    P®EP

    IC®

    HIT

    RON

    IC®

    ETH

    ERLI

    NE®

    UN

    ITRO

    NIC

    ®AP

    PEN

    DIX

    For current information see: www.lappgroup.com

    Selection tables A7UNITRONIC® BUS and ETHERLINE® – technical data

    Usage criteria Cable designationPage 429 429 429 429 420 435 444 444 449

    ETH

    ERLI

    NE®

    PN

    Cat

    .5e

    Y

    ETH

    ERLI

    NE®

    TRA

    Y ER

    PN

    Y F

    C

    ETH

    ERLI

    NE®

    Y F

    C C

    at.5

    ETH

    ERLI

    NE®

    Cat

    .5e

    YY

    ETH

    ERLI

    NE®

    FD

    P C

    at.5

    e

    ETH

    ERLI

    NE®

    FD

    P F

    C C

    at.5

    hi

    ghly

    flex

    ible

    app

    licat

    ion

    ETH

    ERLI

    NE®

    PN

    Cat

    .6A

    FRN

    C F

    C +

    ETH

    ERLI

    NE®

    PN

    Cat

    .7 F

    RNC

    ETH

    ERLI

    NE®

    PN

    Cat

    .6A

    P FC

    +ET

    HER

    LIN

    E® P

    N C

    at.7

    P

    ETH

    ERLI

    NE®

    PN

    Cat

    .6A

    Y FC

    +ET

    HER

    LIN

    E® P

    N +

    Cat

    .7 Y

    ETH

    ERLI

    NE®

    PN

    Cat

    .6A

    Y FL

    EX F

    C

    ETH

    ERLI

    NE®

    PN

    Cat

    .6A

    FRN

    C F

    LEX

    FC

    ETH

    ERLI

    NE®

    FD

    Cat

    .6A

    + TO

    RSIO

    N Y

    Cat

    .6A

    ETH

    ERLI

    NE®

    FD

    P C

    at.6

    A + T

    ORS

    ION

    P C

    at.6

    A

    ETH

    ERLI

    NE®

    TO

    RSIO

    N C

    at.7

    Parameter

    Characteristic impedance Ω 100 100 100 100 100 100 100 100 100 100 100 100 100 100

    Mutual capacitance (800 Hz) max. nF/km 48 48 48 48 50 52 – – – – – – – 50

    Peak operating voltage V (not for power applications)

    125 125 125 125 125 125 125 125 125 125 125 125 125 125

    Test voltage, core/core, Ueff V 1000 2000 1000 1000 1000 700 1000 1000 1000 1000 1000 1000 1000 750

    Conductor resistance (loop) Data network cable pair max. Ω/km

    118 115 115 118 290 120 118 118 118 143 143 175 175 175

    Minimum bending radius, fixed installation 7.5 x D 10 x D 10 x D 4 x D 8 x D 5 x D 4 x D 4 x D 4 x D 8 x D 8 x D 8 x D 8 x D 8 x D

    Minimum bending radius, flexing 15 x D 15 x D 15 x D 8 x D 15 x D 8 x D 8 x D 8 x D 8 x D 15 x D 15 x D 15 x D 15 x D 15 x D

    Temperature range from °Cfixed installation to °C

    - 40 + 70

    - 40 + 80

    - 40 + 80

    - 25 + 80

    - 30 + 80

    - 30 + 70

    - 25 + 80

    - 40 + 80

    - 30 + 80

    - 10 + 70

    - 25 + 80

    - 40 + 80

    - 40 + 80

    - 40 + 80

    Temperature range from °Cflexing to °C

    - 5 + 50

    - 20 + 60

    - 20 + 60

    - 5 + 70

    - 5 + 70

    - 20 + 60 – – –

    - 10 + 70

    - 25 + 80

    - 10 + 70

    - 30 + 70

    - 30 + 70

    Usage criteria Cable designationPage 328 328 329 329 329 328 361 361 361 361 378 378 378

    UN

    ITRO

    NIC

    ® B

    US

    ASI (

    G) y

    ello

    w +

    bla

    ck

    fixed

    inst

    alla

    tion/

    flexi

    ble

    UN

    ITRO

    NIC

    ® B

    US

    ASI (

    TPE)

    yel

    low

    + b

    lack

    fix

    ed in

    stal

    latio

    n/fle

    xibl

    e

    UN

    ITRO

    NIC

    ® B

    US

    ASI L

    D F

    D P

    ye

    llow

    + b

    lack

    hi

    ghly

    flex

    ible

    app

    licat

    ion

    UN

    ITRO

    NIC

    ® B

    US

    ASI F

    D (T

    PE) A

    ye

    llow

    + b

    lack

    hi

    ghly

    flex

    ible

    app

    licat

    ion

    UN

    ITRO

    NIC

    ® B

    US

    ASI F

    D P

    FRN

    C

    yello

    w +

    bla

    ck

    fixed

    inst

    alla

    tion

    UN

    ITRO

    NIC

    ® B

    US

    ASI (

    PVC

    ) A

    yello

    w +

    bla

    ck

    fixed

    inst

    alla

    tion

    UN

    ITRO

    NIC

    ® D

    evic

    eNet

    TH

    ICK

    + TH

    IN (h

    alog

    en-fr

    ee)

    fixed

    inst

    alla

    tion

    UN

    ITRO

    NIC

    ® D

    evic

    eNet

    TH

    ICK

    + TH

    IN (P

    VC)

    fixed

    inst

    alla

    tion

    UN

    ITRO

    NIC

    ® D

    evic

    eNet

    TH

    ICK

    + TH

    IN (P

    UR)

    hi

    ghly

    flex

    ible

    UN

    ITRO

    NIC

    ® D

    evic

    eNet

    TH

    ICK

    + TH

    IN (P

    VC)

    high

    ly fl

    exib

    le

    UN

    ITRO

    NIC

    ® B

    US

    SAFT

    EY

    fixed

    inst

    alla

    tion/

    high

    ly fl

    exib

    le

    UN

    ITRO

    NIC

    ® B

    US

    EIB

    fixed

    inst

    alla

    tion

    UN

    ITRO

    NIC

    ® B

    US

    EIB

    CO

    MBI

    fixed

    inst

    alla

    tion

    Parameter

    Characteristic impedance Ω – – – – – – 120 120 120 120 100- 200 – –

    Mutual capacitance (800 Hz) max. nF/km – – – – – – 39.8 39.8 39.8 39.8 45 max. 100max. 100

    Peak operating voltage V (not for power applications)

    300 300 300 300 300 300 300 300 300 300 250 250 250

    Test voltage, core/core, Ueff V 2000 2000 2000 2000 2000 2000 2000 2000 2000 2000 3000 4000 4000

    Conductor resistance (loop) Data network cable pair max. Ω/km

    27.4 27.4 16.5 27.4 27.4 27.4 THICK 45THIN 180THICK 45THIN 180

    THICK 45THIN 180

    THICK 45THIN 180 52

    max. 130

    max. 130

    Minimum bending radius, fixed installation 3 x D 3 x D 3 x D 3 x D 3 x D 3 x D 10 x D 10 x D – – 8 x D 10 x D 10 x D

    Minimum bending radius, flexing – – 6 x D 6 x D – – – – 10 x D 10 x D – – –

    Temperature range from °Cfixed installation to °C

    - 40 + 85

    - 40 + 85

    - 40 + 80

    - 40 + 105

    - 40 + 80

    - 30 + 90

    - 25 + 80

    - 20 + 80 – –

    - 40 + 80

    - 30 + 70

    - 30 + 70

    Temperature range from °Cflexing to °C – –

    - 30 + 70

    - 30 + 105

    - 30 + 70 – – –

    - 40 + 80

    - 10 + 80

    - 30 + 80 – –

    1078_HK18_int_A7 UNITRONIC® BUS and ETHERLINE®1079_HK18_int_A7 UNITRONIC® BUS and ETHERLINE®1080_HK18_int_A7 UNITRONIC® BUS and ETHERLINE®1081_HK18_int_A7 UNITRONIC® BUS and ETHERLINE®