Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA
A10
Series D1FSProportional Directional Control Valves
Technical Information
General Description
The D1FS Series of proportional directional controlvalves provide variable output flow in response tovariable input commands. The valves feature anon–board LVDT to reduce hysteresis. Optimalperformance is realized when the valves are driven bythe AS20 driver board.
Features
• LVDT –– The spool position feedback is locatedbetween the valve body and coil. This feature allowsfor operation of the valve via the manual overrideslocated at the end of each coil.
• Electrical Interface –– The standard connection isa 1/2 NPT NEMA conduit with pigtails for coilconnection, and a four pin MS style connector forthe LVDT.
• Mounting –– The body counterbore depth placesthe heads of the mounting bolts below the spoolcenterline to reduce the chance of spool bindingdue to improper torquing.
Specifications
Interface
Maximum Pressure
Flow
Solenoid
Repeatability
Hysteresis
Nominal Deadband
Operating Temp.
Range (Ambient)
NFPA D03/CETOP 3
345 Bar (5000 PSI)
35 Bar (500 PSI)
Up to 38 LPM (10 GPM)
12 VDC, 6 ohms, 2 amps
Less than 1%
Less than 1%
10%
–29 to 60°C (–20 to 140°F)
Max. Tank Line Pressure
Viscosity
Fluid Cleanliness
75–600 SSU
ISO Class 16/13, SAE Class 4
or better
(see figure 1)
(see figure 1)
LVDT Characteristics
Primary (Pin A and B)
DC Resistance, 120 ohms
Secondary (Pin C and D)
DC Resistance, 340 ohmsCharacteristics
OperationWhen used in conjunction with our AS20 driver, theD1FS valve will provide the user with desirablecontrol options such as electronic null adjustment,ramp control, velocity limiting, deadband eliminationand an external closed loop feedback option.
Installation note: Valve should be mounted horizontally.(See Installation Information)
7.6 L/M (2 GPM) @ 145 ∆P15.1 L/M (4 GPM) @ 145 ∆P
Protection Class Nema 1 (IP50)
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA
A11
Series D1FSProportional Directional Control Valves
Performance Curves
(Maximum Pressure Drop / Flow Envelope)
P→A + B→T or P→B + A→TNominal Supply Voltage
Flow
5000
4000
3000
2000
1000
05 10
PressureDrop
E01C
1 2 3 4 6 7 8 9
Figure 1
Flow
E01C
Looped Flow Path
Command Signal (% of Max. Signal)
P→A + B→T∆P = 145 PSI *
P→B + A→T∆P = 145 PSI *
Figure 2
0
345
69
138
207
276
BarPSI
LPM
GPM
18.9 37.93.8 7.6 11.4 15.1 22.7 26.5 30.3 34.1
(4)
(3)
(2)
(1)
0
15.1
11.4
7.6
3.8
–100 –80 –60 –40 –20 20 40 60 80 100
Flow vs. Input Command
E02C
E01FE02F
Loop
Operating Limits
at 100% Command Signal
E02C
E01FE02F
LPM (GPM)
See important installation information at the end of Section A
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA
A12
Series D1FSProportional Directional Control Valves
Dimensions
Model D1FS Bi–Directional
172.0(6.77)
143.3(5.64)
23.9(.94)
315.2(12.41)
66.0(2.60)
46.0(1.81)
Ref.
90.9(3.58)
Model D1FS**K Uni–Directional
A
P
T
B
A
P
T
B
Ref.
240.0(9.45)
250.2(9.85)
172.0(6.77)
Inch equivalents for millimeter dimensions are shown in (**)
23.9(.94)
66.0(2.60)
46.0(1.81)
90.9(3.58)
THIRD–ANGLEPROJECTION
AB
A
Parker Hannifin CorporationHydraulic Valve DivisionElyria, Ohio 44035 USA
A13
Series D1FSProportional Directional Control Valves
Ordering Information
D1F
ControlOption
Spool Style DesignSeries
D03ElectrohydraulicDirectional Flow
Control Valve
Integral LVDT Code Description
K12 VDCproportional solenoid
Code Description
N
V
Nitrile
Viton
Not Required for Ordering
SolenoidVoltage
SealOption
Code
A B
P T
A B
P T
01
02
Code Description Symbol
Bi–Directional
Uni–DirectionalFlow P→A & B→T
C
K
LVDT
A B
P T
LVDT
A B
P T
Cables
Code
EHC
3
6
9
12
15
ElectrohydraulicCable for
D1FS Valve
Length
Length
in
feet
Code
44–wire,20 gauge,shielded
Note: For D1FS LVDT mating connector only, order part #800772 (4–pin)
Use AS20 driver board
Weight: Single Solenoid 2.7 kg (6.0 lbs.); Double Solenoid 2.9 kg (6.5 lbs.)
Code
Pin orientationfor D1FS LVDTconnector
Y
S 11
EqualMetering
E
Spool
Length Cable Type Connector Type
Description Description
K
4 Y
FlowCode
C
ValveAccessory
0
Code Nominal Flow @∆P=10 Bar (145 PSI)
C
F
7.5 LPM (2.0 GPM)
15 LPM (4.0 GPM)
Code Description
0 Standard
Code Description
C Conduit Box
SolenoidAccessory
Bolt Kit No. #BK209, 10–24 x 1 1/4”
Mounting Bolt Torque: 5.6 N.m. (50 in–lbs.)
Use Power Supply #PS24, 24 VDC
LocationSubplate Port Size Max.
SPD23
SPD2330
SPD23S
SPD23SA
3/8” NPTF
3/8” NPTF
9/16–18 SAE
9/16–18 SAE
Bottom
Bottom
Bottom
Side
3,000 PSI
5,000 PSI
3,000 PSI
3,000 PSI
Pressure