9500 MPR 33 User Manual MSS1-c

366
User Manual Indoor: MSS-1c + Outdoor: MPT-HC/MPT-HC V2/MPT-MC 9500 MPR-E 3DB18961DAAA Issue 1 Rel. 3.3.0 December 2011

description

alcatel 9500 MPR Manual

Transcript of 9500 MPR 33 User Manual MSS1-c

  • alAAe 1011User Manu

    Indoor: MSS-1c + Outdoor: MPT-HC/MPT-HC V2/MPT-MC

    9500 MPR-E

    3DB18961DAIssu

    Rel. 3.3.0

    December 2

  • Status: RELEASED

    All rights reserved.Passing on and copying of this document,

    use and communication of its contents is not permittedwithout written authorization from Alcatel-Lucent.

    3DB18961DAAA Issue 1

    Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent.

    All other trademarks are the property of their respective owners.

    The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.

    Copyright 2011 Alcatel-Lucent

  • TABLE OF CONTENTS

    LIST OF FIGURES ......................................................................................................................... 5

    LIST OF TABLES ........................................................................................................................... 11

    PREFACE......................................................................................................................................... 13Preliminary Information.............................................................................................................. 13Applicability................................................................................................................................. 14Scope ........................................................................................................................................... 14History.......................................................................................................................................... 14Change notes .............................................................................................................................. 15Handbook Structure ................................................................................................................... 15General on Alcatel-Lucent Customer Documentation ............................................................ 16

    1 SAFETY, EMC, EMF, ESD NORMS AND EQUIPMENT LABELLING ........................................ 211.1 Declaration of conformity to CE marking and Countries List ......................................... 221.2 Specific label for MPR equipment ...................................................................................... 231.3 Applicable standards and recommendations ................................................................... 231.4 Safety Rules ......................................................................................................................... 24

    1.4.1 General Rules................................................................................................................. 241.4.2 Labels Indicating Danger, Forbiddance, Command........................................................ 25

    1.5 Electromagnetic Compatibility (EMC norms).................................................................... 291.6 Equipment protection against electrostatic discharges .................................................. 301.7 Cautions to avoid equipment damage ............................................................................... 301.8 Waste from Electrical and Electronic Equipment (WEEE) ............................................... 31

    2 PRODUCT INFORMATION AND PLANNING ............................................................................. 332.1 9500 Family overview .......................................................................................................... 35

    2.1.1 9500 MPR System Family .............................................................................................. 392.1.2 Family elements described in this User Manual ............................................................. 402.1.3 MSS-1c ........................................................................................................................... 402.1.4 MPT-HC .......................................................................................................................... 412.1.5 MPT-HC V2..................................................................................................................... 422.1.6 MPT-MC.......................................................................................................................... 422.1.7 MSS-1c to MPT-HC interconnection ............................................................................... 432.1.8 MSS-1c to MPT-HC V2 interconnection.......................................................................... 452.1.9 MSS-1c to MPT-MC interconnection............................................................................... 472.1.10 Antennas....................................................................................................................... 47

    2.2 Radio capacity, channelling and modulation (MPT-HC/MPT-HC V2/MPT-MC)................ 482.3 Standard Features ............................................................................................................... 512.4 Radio Configurations .......................................................................................................... 512.5 Typical System Configurations .......................................................................................... 522.6 Environmental and Electrical Characteristics................................................................... 53

    2.6.1 General characteristics (MSS-1c) ................................................................................... 532.6.2 General characteristics (MPT-HC/MPT-HC V2/MPT-MC)............................................... 542.6.3 MPT-MC characteristics.................................................................................................. 552.6.4 MPT-HC/MPT-HC V2 characteristics .............................................................................. 562.6.5 Radio performances ....................................................................................................... 572.6.6 General characteristics (Power Extractor) ...................................................................... 58

    2.7 Parts Lists............................................................................................................................. 592.7.1 MSS-1c ........................................................................................................................... 592.7.2 MPT-HC optical interface option ..................................................................................... 592.7.3 MPT-HC V2 external modules (optional) ........................................................................ 592.7.4 MPT-HC with internal diplexer ........................................................................................ 60User Manual

    Table of Contents

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 1/362

  • 2.7.5 MPT-HC V2 with internal diplexer ................................................................................... 622.7.6 MPT-MC with internal diplexer ........................................................................................ 642.7.7 MPT-HC/MPT-HC V2/MPT-MC with external diplexer .................................................... 66

    2.8 Functional description ........................................................................................................ 732.8.1 MSS-1c (Indoor Unit) ...................................................................................................... 732.8.2 Fan unit ........................................................................................................................... 772.8.3 MPT-HC .......................................................................................................................... 782.8.4 Power Extractor .............................................................................................................. 862.8.5 MPT-HC V2..................................................................................................................... 872.8.6 MPT-MC.......................................................................................................................... 882.8.7 Radio Transmission Features with MPT-HC/MPT-HC V2/MPT-MC................................ 892.8.8 TMN communication channels ....................................................................................... 912.8.9 Traffic profiles ................................................................................................................. 922.8.10 Ethernet Traffic Management ....................................................................................... 972.8.11 Quality Of Services (QoS)............................................................................................. 982.8.12 Cross-connections ........................................................................................................ 1022.8.13 Synchronization ............................................................................................................ 104

    3 NE MANAGEMENT BY SOFTWARE APPLICATION................................................................. 1073.1 WebEML start ....................................................................................................................... 1073.2 Tool bar ................................................................................................................................. 1093.3 Alarm Synthesis................................................................................................................... 1103.4 Domain Alarm Synthesis Area............................................................................................ 1103.5 General Information on the Management State ................................................................ 1113.6 Navigator area...................................................................................................................... 112

    3.6.1 Commissioning ............................................................................................................... 1133.6.2 Performance Monitoring ................................................................................................. 1553.6.3 Troubleshooting .............................................................................................................. 1663.6.4 Maintenance ................................................................................................................... 1693.6.5 Monitoring ....................................................................................................................... 170

    4 INSTALLATION............................................................................................................................ 1794.1 Installation & Interconnection overview ............................................................................ 1794.2 Hardware Installation........................................................................................................... 183

    4.2.1 Power consumption ........................................................................................................ 1834.2.2 Rack Installation ............................................................................................................. 1844.2.3 MSS-1c installation ......................................................................................................... 1944.2.4 MPT-HC Installation ........................................................................................................ 2004.2.5 MPT-HC V2 Installation................................................................................................... 2404.2.6 MPT-MC Installation........................................................................................................ 2524.2.7 Power Extractor .............................................................................................................. 2724.2.8 Indoor Installation ........................................................................................................... 2734.2.9 Antenna Alignment ......................................................................................................... 283

    4.3 Software local copy ............................................................................................................. 2924.3.1 Getting Started................................................................................................................ 2924.3.2 PC Characteristics .......................................................................................................... 2924.3.3 Local copy of the Software Package (SWP) to the PC................................................... 2944.3.4 Local copy the WebEML to PC....................................................................................... 2954.3.5 Configure PC Network Card to Connect to NE............................................................... 301

    5 PROVISIONING............................................................................................................................ 303

    6 MAINTENANCE AND TROUBLE-CLEARING ............................................................................ 3076.1 Introduction .......................................................................................................................... 3076.2 Maintenance Philosophy..................................................................................................... 308User Manual

    Table of Contents

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 12/362

  • 6.3 Personal Computer (PC)/Laptop ........................................................................................ 3086.4 Troubleshooting................................................................................................................... 308

    6.4.1 Before Going to Site Checklist ........................................................................................ 3086.4.2 Network Supervision Troubleshooting ............................................................................ 3106.4.3 Troubleshooting Basics................................................................................................... 3116.4.4 Relationship between the alarms on the MCT and SNMP traps..................................... 3176.4.5 Troubleshooting with MSS-1c electrical or optical connection........................................ 3216.4.6 Troubleshooting Path Problems...................................................................................... 3226.4.7 Troubleshooting Configuration Problems........................................................................ 3236.4.8 Troubleshooting Ethernet Problems ............................................................................... 3246.4.9 Troubleshooting TMN Problems ..................................................................................... 325

    6.5 Failed equipment removal and replacement ..................................................................... 3276.5.1 MSS-1c removal and replacement ................................................................................. 3276.5.2 MSS-1c replaced by MSS-1c 16E1 ................................................................................ 3276.5.3 MSS-1c 16E1 replaced by MSS-1c ................................................................................ 3286.5.4 MPT-HC removal and replacement................................................................................. 3286.5.5 MPT-HC V2 removal and replacement ........................................................................... 3286.5.6 MPT-MC removal and replacement ................................................................................ 328

    6.6 Cleaning................................................................................................................................ 329

    7 LINEUP AND COMMISSIONING ............................................................................................... 3317.1 Introduction .......................................................................................................................... 332

    7.1.1 General ........................................................................................................................... 3327.1.2 SafetyEMCEMFESD norms and cautions to avoid equipment damage................... 3337.1.3 Conventions.................................................................................................................... 3337.1.4 Summary of the lineup, commissioning, and acceptance phases ................................ 3347.1.5 How to access the remote NE ........................................................................................ 335

    7.2 Commissioning of STATION A phase 1 (Turn up).......................................................... 3377.2.1 Turnon preliminary operations ...................................................................................... 3377.2.2 Powering up the MSS-1c(s) with ODU(s) connected...................................................... 338

    7.3 Commissioning of STATION B phase 1 (Turn up).......................................................... 3387.4 Fine antenna alignment and preliminary checks Stations A & B................................. 339

    7.4.1 Fine antenna alignment .................................................................................................. 3397.4.2 Preliminary checks.......................................................................................................... 339

    7.5 End of commissioning phase 1 (Turn up) in STATION A ................................................. 3407.6 Commissioning station A phase 2 (acceptance test) .................................................... 341

    7.6.1 Installation and cabling visual inspection ........................................................................ 3437.6.2 System configuration ...................................................................................................... 3437.6.3 E1 traffic.......................................................................................................................... 3457.6.4 Ethernet traffic................................................................................................................. 3467.6.5 NE configuration ............................................................................................................. 3467.6.6 Data/Time settings .......................................................................................................... 3477.6.7 Hop E1 stability test ........................................................................................................ 3477.6.8 Ethernet Traffic stability test............................................................................................ 349

    7.7 Commissioning station B Phase 2 (acceptance Test) ................................................... 3537.8 Final operations ................................................................................................................... 3537.9 Annex A: fine antenna alignment ....................................................................................... 353

    ABBREVIATIONS ............................................................................................................................ 355

    CUSTOMER DOCUMENTATION FEEDBACK.............................................................................. 361User Manual

    Table of Contents

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 3/362

  • User Manual

    Table of Contents

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 14/362

  • LIST OF FIGURES

    Figure 1. Multiservice Aggregation Layer ......................................................................................... 37Figure 2. Service Awareness ............................................................................................................ 37Figure 3. Packet Node ...................................................................................................................... 38Figure 4. Service-driven Packet Adaptive Modulation ...................................................................... 38Figure 5. 9500 MPR System Family ................................................................................................. 39Figure 6. MPT-HC ............................................................................................................................. 41Figure 7. MPT-HC V2........................................................................................................................ 42Figure 8. MPT-MC............................................................................................................................. 42Figure 9. MPT-HC connection (electrical cable) ............................................................................... 43Figure 10. MPT-HC connection (optical cable + power supply cable to MSS-1c)............................. 44Figure 11. MPT-HC connection (optical cable + power supply cable to Station battery)................... 44Figure 12. MPT-HC V2 connection ................................................................................................... 45Figure 13. MPT-HC V2 connection (optical cable + power supply cable from MSS-1c) ................... 46Figure 14. MPT-HC V2 connection (optical cable + power supply cable from Station battery)......... 46Figure 15. MPT-MC connection ........................................................................................................ 47Figure 16. TDM Over Ethernet Packet Node - Mapping of E1/T1 TDM on Ethernet ........................ 52Figure 17. TDM and Ethernet Terminal Packet Transport E1/T1 TDM and 1 Radio Direction.......... 52Figure 18. MSS-1c block diagram..................................................................................................... 73Figure 19. MSS-1c front view............................................................................................................ 74Figure 20. MSS-1c rear view ............................................................................................................ 74Figure 21. MSS-1c and Fan unit ....................................................................................................... 77Figure 22. MPT system..................................................................................................................... 79Figure 23. 11-38 GHz MPT-HC housing ........................................................................................... 79Figure 24. 6 GHz MPT-HC housing .................................................................................................. 79Figure 25. 7-8 GHz MPT-HC housing ............................................................................................... 80Figure 26. MPT-HC block diagram.................................................................................................... 80Figure 27. 7/8 GHz MPT-HC architecture ......................................................................................... 83Figure 28. 11 to 38 GHz MPT-HC architecture ................................................................................. 83Figure 29. Power Extractor ............................................................................................................... 86Figure 30. MPT-HC V2 housing (internal diplexer) ........................................................................... 87Figure 31. MPT-MC housing (internal diplexer) ................................................................................ 88Figure 32. MPT-MC housing (external diplexer) ............................................................................... 88Figure 33. Available loopbacks ......................................................................................................... 90Figure 34. Traffic profiles .................................................................................................................. 92Figure 35. Traffic profiles .................................................................................................................. 93Figure 36. E1 Traffic.......................................................................................................................... 94Figure 37. E1 Traffic.......................................................................................................................... 95Figure 38. E1 Traffic.......................................................................................................................... 96Figure 39. QoS in the MSS-1c .......................................................................................................... 98Figure 40. QoS in the MPT ............................................................................................................... 100Figure 41. Cross-connection............................................................................................................. 102Figure 42. E1 from/to Radio port....................................................................................................... 102Figure 43. E1 from/to Ethernet port .................................................................................................. 103Figure 44. Main view: System Overview........................................................................................... 109Figure 45. Tool bar ............................................................................................................................ 109Figure 46. Inventory .......................................................................................................................... 113Figure 47. Software Download: Software Package versions ............................................................ 114Figure 48. Software download .......................................................................................................... 115Figure 49. Software Download: Active Software Package summary ................................................ 116Figure 50. Software Download: Stand-by Software Package summary............................................ 116Figure 51. Date/Time Configuration .................................................................................................. 117Figure 52. Site Information................................................................................................................ 118User Manual

    List of Figures

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 5/362

  • Figure 53. Protection Configuration .................................................................................................. 118Figure 54. Radio Configuration: FCM - RTPC .................................................................................. 121Figure 55. Radio Configuration: FCM - ATPC................................................................................... 121Figure 56. Radio Configuration: ACM - RTPC .................................................................................. 122Figure 57. Advanced Radio Configuration ........................................................................................ 122Figure 58. MSS-1c Configuration...................................................................................................... 123Figure 59. FTP Server Parameters................................................................................................... 124Figure 60. Ethernet ports Provisioning.............................................................................................. 129Figure 61. Cross connection TDM2TDM (E1 case) .......................................................................... 131Figure 62. One shot tributaries Provisioning..................................................................................... 132Figure 63. Cross connection functional scheme ............................................................................... 132Figure 64. Cross connection TDM2TDM (T1 case) .......................................................................... 133Figure 65. Cross connection to user Ethernet port ........................................................................... 135Figure 66. Cross connection functional scheme ............................................................................... 136Figure 67. Management port Provisioning ........................................................................................ 136Figure 68. TDM cross connection between radio and Ethernet port................................................. 137Figure 69. Cross connection functional scheme ............................................................................... 138Figure 70. Network Synchronization Clock Provisioning .................................................................. 138Figure 71. NE bridge mode selection................................................................................................ 140Figure 72. NE bridge mode selection................................................................................................ 141Figure 73. Port VLAN Provisioning ................................................................................................... 142Figure 74. Port VLAN Provisioning ................................................................................................... 143Figure 75. Storm Control and Rate limiting ....................................................................................... 144Figure 76. Per Flow policer ............................................................................................................... 145Figure 77. Network Interfaces........................................................................................................... 146Figure 78. Areas ............................................................................................................................... 147Figure 79. OSPF Areas Management............................................................................................... 147Figure 80. Configuration message.................................................................................................... 147Figure 81. Areas ............................................................................................................................... 148Figure 82. Configuration message.................................................................................................... 148Figure 83. Areas ............................................................................................................................... 148Figure 84. Modify OSPF Area........................................................................................................... 148Figure 85. Interfaces ......................................................................................................................... 149Figure 86. Network interfaces attachment to an OSPF Area............................................................ 149Figure 87. Interfaces ......................................................................................................................... 149Figure 88. Network interfaces attachment to an OSPF Area............................................................ 149Figure 89. Static Routing................................................................................................................... 150Figure 90. Routing Table................................................................................................................... 151Figure 91. Trusted SNMP Managers ................................................................................................ 152Figure 92. Manager registration........................................................................................................ 153Figure 93. Backup / Restore ............................................................................................................. 154Figure 94. Performance History File Upload..................................................................................... 156Figure 95. Qos Ethernet Counter period duration............................................................................. 156Figure 96. Counter Thresholds ......................................................................................................... 157Figure 97. 15Min Counter activation ................................................................................................. 158Figure 98. 15Min Counter ................................................................................................................. 158Figure 99. 15Min Counter history...................................................................................................... 159Figure 100. 15Min Counter deactivation ........................................................................................... 159Figure 101. Import History ................................................................................................................ 160Figure 102. File selection.................................................................................................................. 160Figure 103. Adaptive Modulation counter activation ......................................................................... 161Figure 104. 15Min Counter ............................................................................................................... 162Figure 105. 15Min Counter history.................................................................................................... 162Figure 106. 15Min Counter deactivation ........................................................................................... 163User Manual

    List of Figures

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 16/362

  • Figure 107. Ethernet: QoS Counters ................................................................................................ 164Figure 108. QoS Counters example for Aggregate........................................................................... 165Figure 109. Inventory ........................................................................................................................ 166Figure 110. Loopback activation ....................................................................................................... 167Figure 111. ACM Manual Management............................................................................................. 168Figure 112. ATPC Manual Management (ANSI market only)............................................................ 168Figure 113. Maintenance .................................................................................................................. 169Figure 114. NE Alarms...................................................................................................................... 171Figure 115. Alarm filtering ................................................................................................................. 171Figure 116. Peripheral NE Alarms .................................................................................................... 172Figure 117. Power measurements .................................................................................................... 173Figure 118. Power measurements .................................................................................................... 174Figure 119. Modem measurements .................................................................................................. 175Figure 120. Modem measurements .................................................................................................. 176Figure 121. Events............................................................................................................................ 177Figure 122. Station interconnections with MPT-MC .......................................................................... 179Figure 123. Station interconnections with MPT-HC with Power Extractor......................................... 179Figure 124. Station interconnections with MPT-HC (optical cable + coax. power supply cable to MSS-1c)............................................................................................... 180Figure 125. Station interconnections with MPT-HC (optical cable + coax. power supply cable to Station battery) .................................................................................... 180Figure 126. Station interconnections with MPT-HC V2 (one cable) .................................................. 181Figure 127. Station interconnections with MPT-HC V2 (optical cable + coax. power supply cable to MSS-1c)............................................................................................... 181Figure 128. Station interconnections with MPT-HC V2 (optical cable + coax. power supply cable to Station battery) .................................................................................... 182Figure 129. Fixing the Rack to Floor (1) ........................................................................................... 186Figure 130. Fixing the Rack to Floor (2) ........................................................................................... 187Figure 131. Floor file drilling template............................................................................................... 188Figure 132. Example of securing rack assembly to computer floor .................................................. 189Figure 133. Laborack ........................................................................................................................ 190Figure 134. TRU (6 fuse holders) shown without cover.................................................................... 191Figure 135. TRU (Extension kit to add 6 fuse holders) shown without cover ................................... 191Figure 136. TRU (10 breakers slots) shown without cover ............................................................... 192Figure 137. TRU (20 breakers slots) shown without cover ............................................................... 192Figure 138. TRU (Extension kit to add 10 breakers slots) shown without cover............................... 192Figure 139. Breaker adding .............................................................................................................. 192Figure 140. TRU shown with cover................................................................................................... 193Figure 141. Grounding ...................................................................................................................... 195Figure 142. Grounding ...................................................................................................................... 195Figure 143. Power/Return connection .............................................................................................. 195Figure 144. Installation solution ........................................................................................................ 196Figure 145. Installation solution ........................................................................................................ 196Figure 146. Installation solution ........................................................................................................ 197Figure 147. Interconnections to connector support 1.6/5.6 75 ohm Panel 1U (3CC08061AAAA).... 197Figure 148. Interconnections to connector support BNC 75 ohm Panel 1U (3CC08061ABAA) ....... 198Figure 149. Interconnections to support 19 Inch modules 120 ohm Panel 3U (3CC07810AAAA) ... 198Figure 150. ....................................................................................................................................... 199Figure 151. ....................................................................................................................................... 199Figure 152. Views of MPT-HC with embedded diplexer (11-38 GHz) ............................................... 201Figure 153. Views of MPT-HC with embedded diplexer (6 GHz) ...................................................... 202Figure 154. Views of MPT-HC with external diplexer........................................................................ 202Figure 155. Views of MPT-HC with embedded diplexer (11-38 GHz) ............................................... 204Figure 156. Views of MPT-HC with external diplexer........................................................................ 205User Manual

    List of Figures

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 7/362

  • Figure 157. Views of MPT-HC with embedded diplexer (6 GHz) ...................................................... 206Figure 158. Composition of MPT-HC with external diplexer ............................................................. 207Figure 159. MPT-HC TRANSCEIVER and BRANCHING boxes coupling surfaces ......................... 208Figure 160. Label affixed on the MPT-HC and MPT-HC TRANSCEIVER box.................................. 209Figure 161. Label affixed inside the MPT-HC BRANCHING box ...................................................... 210Figure 162. Example of integrated antenna Pole Mounting (with antenna and nose adapter) ...................................................................................................... 213Figure 163. "Pole Mounting for Remote ODU" Installation kit (3DB10137AAXX)............................ 214Figure 164. Example of antenna polarization change (1+0 MPT-HC integrated antenna) ............. 215Figure 165. Putting silicone grease on O-ring before MPT-HC insertion .......................................... 216Figure 166. MPT-HC 1+0 installation for integrated antenna (11-38 GHz) ....................................... 216Figure 167. MPT-HC 1+0 installation for integrated antenna (6-7-8 GHz: vertical polarization) ....... 217Figure 168. MPT-HC 1+0 installation for integrated antenna (6-7-8 GHz: horizontal polarization) ... 217Figure 169. "Pole Mounting for Remote ODU" installation................................................................ 218Figure 170. Putting silicone grease on O-ring before MPT-HC insertion .......................................... 218Figure 171. MPT-HC 1+0 installation for not integrated antenna (11-38 GHz with pole mounting P/N 3DB10137AAXX) ....................................................................................................................... 219Figure 172. MPT-HC 1+0 installation for not integrated antenna (6-7-8 GHz with pole mounting P/N 3DB10137AAXX) ....................................................................................................................... 219Figure 173. Locations for Cable Grounds ......................................................................................... 236Figure 174. Example of realization ................................................................................................... 238Figure 175. Detail of the waterproofing of the kit .............................................................................. 239Figure 176. Views of MPT-HC V2 with embedded diplexer .............................................................. 241Figure 177. RPS module................................................................................................................... 243Figure 178. XPIC + RPS module ...................................................................................................... 243Figure 179. External module installed............................................................................................... 244Figure 180. Correct screw position ................................................................................................... 244Figure 181. Views of MPT-HC V2 with embedded diplexer .............................................................. 246Figure 182. Views of MPT-HC V2 with external diplexer .................................................................. 247Figure 183. Label affixed on the MPT-HC V2 and MPT-HC V2 TRANSCEIVER box....................... 248Figure 184. Label affixed inside the MPT-HC V2 BRANCHING box................................................. 249Figure 185. LC/Q-XCO to LC Fiber cord........................................................................................... 250Figure 186. Views of MPT-MC with embedded diplexer ................................................................... 253Figure 187. Views of MPT-MC with external diplexer ....................................................................... 254Figure 188. Views of MPT-MC with embedded diplexer ................................................................... 255Figure 189. Views of MPT-MC with external diplexer ....................................................................... 255Figure 190. Composition of MPT-MC with external diplexer ............................................................. 256Figure 191. MPT-MC TRANSCEIVER and BRANCHING boxes coupling surfaces ......................... 257Figure 192. Label affixed on the MPT-MC and MPT-MC TRANSCEIVER box................................. 258Figure 193. Label affixed inside the MPT-MC BRANCHING box...................................................... 259Figure 194. Example of antenna polarization change (1+0 MPT-MC integrated antenna)............. 262Figure 195. Putting silicone grease on O-ring before MPT-MC insertion.......................................... 263Figure 196. MPT-MC 1+0 installation for integrated antenna (6 GHz and 11-38 GHz)..................... 263Figure 197. MPT-MC 1+0 installation for integrated antenna (7-8 GHz: vertical polarization) .......... 264Figure 198. MPT-MC 1+0 installation for integrated antenna (7-8 GHz: horizontal polarization)...... 264Figure 199. "Pole Mounting for Remote ODU" installation................................................................ 265Figure 200. Putting silicone grease on O-ring before MPT-MC insertion.......................................... 265Figure 201. MPT-MC 1+0 installation for not integrated antenna (with pole mounting P/N 3DB10137AAXX) ....................................................................................................................... 266Figure 202. Kit plug R2CT ................................................................................................................ 267Figure 203. Kit plug R2CT items....................................................................................................... 267Figure 204. MPT/AWY Service Cord ................................................................................................ 285Figure 205. Checking Feedhead Flange with a Spirit level............................................................... 288Figure 206. Indicative head-on signal pattern for a parabolic antenna ............................................. 290User Manual

    List of Figures

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 18/362

  • Figure 207. Example Tracking Path Signals ..................................................................................... 291Figure 208. Example Tracking Path Signals on the First Side Lobe................................................. 291Figure 209. PC connection (MPT-MC/MPT-HC) ............................................................................... 303Figure 210. PC connection (MPT-HC V2): two different solutions .................................................... 304Figure 211. MSS-1c replaced by MSS-1c 16E1 ............................................................................... 327Figure 212. File conversion............................................................................................................... 327Figure 213. Relative positions of stations A and B ........................................................................... 333Figure 214. Test bench for tributary functionality check with MPT-HC/MPT-MC............................... 345Figure 215. Test bench for tributary functionality check with MPT-HC/MPT-MC............................... 348Figure 216. Test bench for optional Ethernet Data Channel functionality with 1 additional PC and 1 Ethernet cable................................................................................................................................... 350Figure 217. Test bench for optional Ethernet Data Channel functionality with 2 additional PCs ..... 351Figure 218. Test bench for optional Ethernet Data Channel functionality with 2 Ethernet Data Analyzers ................................................................................................................ 352User Manual

    List of Figures

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 9/362

  • User Manual

    List of Figures

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 110/362

  • LIST OF TABLES

    Table 1. Radio capacity, channelling scheme and modulation (Static Modulation) ........................... 48Table 2. Radio capacity, channelling scheme and modulation (Adaptive Modulation)...................... 50Table 3. MSS-1c item codes ............................................................................................................. 59Table 4. CD-ROM Software codes.................................................................................................... 59Table 5. MPT-HC option.................................................................................................................... 59Table 6. MPT-HC V2 external modules............................................................................................. 59Table 7. MPT-HC codes with internal diplexer .................................................................................. 60Table 8. MPT-HC V2 codes with internal diplexer ............................................................................. 62Table 9. MPT-MC codes with internal diplexer .................................................................................. 64Table 10. 6 and 7/8 GHz MPT-MC codes with external diplexer....................................................... 66Table 11. MPT-HC V2 codes with external diplexer .......................................................................... 67Table 12. 7/8 GHz MPT-HC codes with external diplexer ................................................................. 67Table 13. 7/8 GHz MPT-HC V2 High Power codes with external diplexer ........................................ 67Table 14. 7 GHz Branching assemblies (for MPT-HC and MPT-MC)................................................ 68Table 15. 7 GHz High Power Branching assemblies (for MPT-H2 V2 High Power).......................... 69Table 16. 8 GHz Branching assemblies (for MPT-HC and MPT-MC)................................................ 70Table 17. 8 GHz High Power Branching assemblies (for MPT-H2 V2 High Power).......................... 71Table 18. 5.8 GHz Branching assemblies (for MPT-HC and MPT-MC)............................................. 71Table 19. 10.5 GHz Branching assemblies (for MPT-HC and MPT-MC)........................................... 72Table 20. 6 GHz Lower Branching assemblies (for MPT-HC and MPT-MC)..................................... 72Table 21. 6 GHz Upper Branching assemblies (for MPT-HC and MPT-MC)..................................... 72Table 22. RSSI Table ........................................................................................................................ 85Table 23. Waveguide Flange Data .................................................................................................... 85Table 24. Power distribution panel kits.............................................................................................. 191Table 25. Recommended breaker/fuse values (A)............................................................................ 193Table 26. MPT-HC external interfaces ............................................................................................. 203Table 27. RF interface...................................................................................................................... 203Table 28. MPT-HC Output flanges with external antenna ................................................................. 233Table 29. 6-7-8GHz Flextwist waveguide.......................................................................................... 234Table 30. 11-38GHz Flextwist waveguide ......................................................................................... 234Table 31. MPT-HC V2 external interfaces........................................................................................ 245Table 32. RF interface...................................................................................................................... 245Table 33. MPT-MC external interfaces............................................................................................. 254Table 34. RF interface...................................................................................................................... 254Table 35. Pin Function: Tributaries 1- 8 ............................................................................................ 281Table 36. Pin Function: Tributaries 9- 16 .......................................................................................... 282Table 37. MSS-1c Alarm Matrix (Equipment Type) ........................................................................... 312Table 38. MSS-1c Alarm Matrix (Communication Type) ................................................................... 312Table 39. MPT Alarm Matrix (Equipment Type) ................................................................................ 314Table 40. MPT Alarm Matrix (Communication Type)......................................................................... 315Table 41. MPT Alarm Matrix (Quality of Service Type) ..................................................................... 316Table 42. MSS-1c SNMP traps (Equipment Type)............................................................................ 317Table 43. MSS-1c SNMP traps (Communication Type) .................................................................... 318Table 44. MPT SNMP traps (Equipment Type) ................................................................................. 319Table 45. MPT SNMP traps (Communication) .................................................................................. 320Table 46. MPT SNMP traps (Quality of Service) ............................................................................... 321Table 47. TMN Network Troubleshooting.......................................................................................... 325Table 48. Test and commissioning instruments ................................................................................ 332User Manual

    List of Tables

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 11/362

  • User Manual

    List of Tables

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 112/362

  • PREFACE

    Preliminary Information

    WARRANTY

    Any warranty must be referred exclusively to the terms of the contract of sale of the equipment to which this handbook refers to.

    AlcatelLucent makes no warranty of any kind with regards to this manual, and specifically disclaims the implied warranties of merchantability and fitness for a particular purpose. AlcatelLucent will not be liable for errors contained herein or for damages, whether direct, indirect, consequential, inci-dental, or special, in connection with the furnishing, performance, or use of this material.

    INFORMATION

    The product specification and/or performance levels contained in this document are for information purposes only and are subject to change without notice. They do not represent any obligation on the part of AlcatelLucent.

    COPYRIGHT NOTIFICATION

    The technical information of this manual is the property of AlcatelLucent and must not be copied, reproduced or disclosed to a third party without written consent.

    SAFETY RECOMMENDATIONS

    The safety recommendations here below must be considered to avoid injuries on persons and/or damage to the equipment:

    1) Service PersonnelInstallation and service must be carried out by authorized persons having appropriate technical training and experience necessary to be aware of hazardous operations during installation and service, so as to prevent any personal injury or danger to other persons, as well as prevent dam-aging the equipment.

    2) Access to the EquipmentAccess to the Equipment in use must be restricted to Service Personnel only.

    3) Safety RulesRecommended safety rules are indicated in Chapter 1 from page 21.User Manual

    Preface

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 13/362

  • Local safety regulations must be used if mandatory. Safety instructions in this handbook should be used in addition to the local safety regulations. In case of conflict between safety instructions stated in this manual and those indicated in local regulations, mandatory local norms will pre-vail. Should not local regulations be mandatory, then safety rules stated in this manual will pre-vail.

    SERVICE PERSONNEL SKILL

    Service Personnel must have an adequate technical background on telecommunications and in par-ticular on the equipment subject of this handbook.

    An adequate background is required to properly install, operate and maintain equipment. The fact of merely reading this handbook is considered as not enough.

    Applicability

    This handbook applies to the following productrelease:

    PRODUCT

    9500 MPR-E

    PRODUCT RELEASE

    MSS-1c/MPT-HC/MPT-HC V2/MPT-MC 3.3.0

    Scope

    This document aims to describe the hardware and software functionalities.

    This document is intended to the technicians involved in Planning, in Operation and Maintenance and in Commissioning.

    History

    ISSUE DATE DESCRIPTIONS

    01 December 2011User Manual

    Preface

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 114/362

  • Change notes

    Handbook Structure

    This handbook has been edited according to the Alcatel-Lucent standardized drawing-up guides" com-plying with such suggestion.

    This handbook is divided into the main topics described in the table of contents:

    PREFACE It contains general information as preliminary information, hand-book scope, history. Furthermore, it describes the handbook struc-ture and the customer documentation.

    SAFETY This section includes all the safety instructions.

    PRODUCT INFORMATIONAND PLANNING

    This section provides the equipment description (at system, MSS-1c and Outdoor levels), introduces the basic information regarding the HW architecture, and gives its technical characteristics.

    NE MANAGEMENT BYSOFTWARE APPLICATIONS

    This section gives the description and use of the SW tools available for the NE management.

    INSTALLATION This section provides whole information regarding Equipment hard-ware installation. Moreover, it contains the whole operative information on: provisioning of equipment items (P/Ns, equipping rules) their physical position in the system unit assembly and front panel drawings, with the description

    on the access point usage (connectors, visual indicators, but-tons).

    This section provides also the whole operative instructions for the preparation of the Craft Terminal for the LineUp and Commission-ing of the two NEs making up the radio link.

    PROVISIONING This section gives all the instructions to provision (to configure) the NE.

    MAINTENANCE AND TROUBLE-CLEARING

    This section contains the whole logical and operative information for the equipment maintenance and system upgrade.

    LINE-UP AND COMMISSIONING

    This section provides all the instructions for the line-up and com-missioning of the NE.

    ABBREVIATIONS The abbreviation list is supplied.

    CUSTOMER DOCUMENTA-TION FEEDBACK

    It contains info regarding customer opinions collection about this documentation.User Manual

    Preface

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 15/362

  • General on Alcatel-Lucent Customer Documentation

    This paragraph describes in general the AlcatelLucent Customer Documentation system, details the association between the product levels and the associated documentation, and explains Customer Doc-umentation characteristics as well as the policies for its delivery and updating.

    CustomerIndependent Standard Customer Documentation

    a) DefinitionStandard Customer Documentation, referred to hereafter, must be always meant as plantindepen-dent and is always independent of any Customization.Plantdependent and/or Customized documentation, if envisaged by the contract, is subjected to commercial criteria as far as contents, formats and supply conditions are concerned.N.B. Plantdependent and Customized documentation is not described here.

    b) Aims of standard Customer DocumentationStandard system, hardware and software documentation is meant to give the Customer personnel the possibility and the information necessary for installing, commissioning, operating, and maintain-ing the equipment according to AlcatelLucent Laboratory design and Installation Dept. choices. In particular: the contents of the chapters associated to the software applications focus on the explanation

    of the manmachine interface and of the operating procedures allowed by it; maintenance is described down to faulty PCB location and replacement.N.B. No supply to Customers of design documentation (like PCB hardware design and production documents and files, software source programs, programming tools, etc.) is envisaged.

    Product levels and associated Customer Documentation

    a) ProductsA product is defined by the network hierarchical level where it can be inserted and by the whole of performances and services that it is meant for.E.g. 9500 MPR is a product.

    b) Product-releasesA product evolves through successive productreleases, which are the real products marketed for their delivery at a certain productrelease availability date. A certain productrelease performs more functionalities than the previous one.E.g. Rel.1.0 and Rel.2.0 are two successive productreleases of the same product.A productrelease comprehends a set of hardware components and at least one Software Pack-age (SWP); as a whole, they identify the possible network applications and the equipment perfor-mances that the specific productrelease has been designed, engineered, and marketed for.

    c) Configurations and Network ElementsIn some cases, a productrelease includes different possible configurations which are distin-guished from one another by different Network Element (NE) types and, from the management point of view, by different SWPs.

    d) SWP releases, versions, and CDROMs Each SWP is distributed by means of a specific SWP CDROM. A SWP is identified by its Denomination, P/N (Part Number) and CS (Change Status), that

    are printed on the CDROMs label: the first and second digits of the Denomination (e.g. 2.0) correspond to the HW product

    release number; the third digit of the of the Denomination (e.g. 2.0.2) identifies the Version Level of the

    SWP.User Manual

    Preface

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 116/362

  • A SWP with new Version Level, providing main features in addition to those of the previous Ver-sion Level SWP, is distributed by means of a SWP CDROM having new Denomination, P/N (Part Number), and CS restarting from 01

    A SWP patch version, if any, is created to correct SW bugs, and/or to add minor features, and is distributed by means of a SWP CDROM, that can be identified: by the same P/N of the former CDROM, but with an incremented CS number

    (e.g.CS=02 instead of previous CS=01) or by a new P/N, and CS restarting from 01.

    Handbook Updating

    The handbooks associated to the "product-release" are listed in History on page 14.

    Each handbook is identified by: the name of the "productrelease" (and "version" when the handbook is applicable to the versions

    starting from it, but not to the previous ones), the handbook name, the handbook Part Number, the handbook edition (usually first edition=01), the handbook issue date. The date on the handbook does not refer to the date of print but to the date

    on which the handbook source file has been completed and released for the production.

    Changes introduced in the same productrelease (same handbook P/N)

    The edition and date of issue might change on future handbook versions for the following reasons:

    only the date changes (pointed out in the Table of Contents) when modifications are made to the edi-torial system not changing the technical contents of the handbook.

    the edition, hence the date, is changed because modifications made concern technical contents. In this case:

    the changes with respect to the previous edition are listed in History on page 14; in affected chapters, revision bars on the left of the page indicate modifications in text and draw-

    ings.

    Changes concerning the technical contents of the handbook cause the edition number increase (e.g. from Ed.01 to Ed.02). Slight changes (e.g. for corrections) maintain the same edition but with the addition of a version character (e.g. from Ed.02 to Ed.02A). Version character can be used for draft or proposal edi-tions.

    NOTES FOR HANDBOOKS RELEVANT TO SOFTWARE APPLICATIONSHandbooks relevant to software applications (typically the Operator's Handbooks) are not modified unless the new software "version" distributed to Customers implies man-machine interface changes or in case of slight modifications not affecting the understanding of the explained procedures.

    Moreover, should the screen prints included in the handbook contain the productrelease's "version" marking, they are not replaced in the handbooks related to a subsequent version, if the screen contents are unchanged.

    Supplying updated handbooks to Customers

    Supplying updated handbooks to Customers who have already received previous issues is submitted to commercial criteria.By updated handbook delivery it is meant the supply of a complete copy of the handbook new issue (sup-plying errata-corrige sheets is not envisaged).User Manual

    Preface

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 17/362

  • Changes due to new product version

    A new product version changes the handbook P/N and the edition starts from 01. In this case the modified parts of the handbook are not listed.

    Customer documentation on CD-ROM

    In the following by 'CD-ROM' it is meant 'Customer Documentation on CD-ROM'

    Contents, creation and production of a CD-ROM

    In most cases, a CD-ROM contains in read-only electronic format the documentation of one product-release(-version) and for a certain language.In some other cases, the same CD-ROM can contain the documentation of different product-release(-ver-sion)s for a certain language.

    As a general rule:

    CD-ROMs for Network Management products do not contain:

    the Installation Guides

    the documentation of system optional features that Customers could not buy from Alcatel-Lucent together with the main applicative SW.

    CD-ROMs for Network Elements products do not contain:

    the documentation of system optional features (e.g. System Installation Handbooks related to racks that Customers could not buy from Alcatel-Lucent together with the main equipment).

    A CD-ROM is obtained collecting various handbooks and documents in .pdf format. Bookmarks and hyperlinks make the navigation easier. No additional information is added to each handbook, so that the documentation present in the CD-ROMs is exactly the same the Customer would receive on paper.

    The files processed in this way are added to files/images for managing purpose and a master CD-ROM is recorded.

    Suitable checks are made in order to have a virus-free product.

    After a complete functional check, the CD-ROM image is electronically transferred to the archive of the Production Department, so that the CD-ROM can be produced and delivered to Customers.

    Use of the CD-ROM

    The CD-ROM can be used both in PC and Unix WS environments.

    The CD-ROM starts automatically with autorun and hyperlinks from the opened Index" document permit to visualize the .pdf handbooks.Other hyperlinks permit to get, from the Technical handbooks, the specific .pdf setting documents.

    In order to open the .pdf documents Adobe Acrobat Reader Version 4.0 (minimum) must have been installed on the platform.The CD-ROM doesn't contain the Adobe Acrobat Reader program. The Customer is in charge of getting and installing it.ReadMe info is present on the CD-ROM to this purpose.

    Then the Customer is allowed to read the handbooks on the PC/WS screen, using the navigation and zooming tools included in the tool, and to print selected parts of the documentation through a local printer.User Manual

    Preface

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 118/362

  • CD-ROM identification

    Each CD-ROM is identified:

    1) by external identifiers, that are printed on the CD-ROM upper surface: the name of the "product-release(s)" (and "version" if applicable) a writing indicating the language(s), the CD-ROM Part Number), the CD-ROM edition (usually first edition=01)

    2) and, internally, by the list of the source handbooks and documents (P/Ns and editions) by whose collection and processing the CD-ROM itself has been created.

    CD-ROM updating

    The list of source handbook/document P/Ns-editions indicated in previous para. point 2), in association with the CD-ROM's own P/N-edition, is also loaded in the Alcatel-Information-System as a structured list.Whenever a new edition of any of such handbooks/documents is released in the Alcatel-Lucent archive system, a check in the Alcatel-Information-System is made to identify the list of CD-ROMs that must be updated to include the new editions of these handbooks/documents.This causes the planning and creation of a new edition of the CD-ROM.

    Updating of CD-ROMs always follows, with a certain delay, the updating of the single handbooks com-posing the collection.User Manual

    Preface

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 19/362

  • User Manual

    Preface

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 120/362

  • 1 Safety, EMC, EMF, ESD Norms and Equipment Labelling

    This chapter describes the equipment labelling and the norms mandatory or suggested that must be con-sidered to avoid injuries on persons and/or damage to the equipment.

    This chapter is organized as follows:

    Declaration of conformity to CE marking and Countries List

    Specific label for MPR equipment

    Applicable standards and recommendations

    Safety Rules

    Electromagnetic Compatibility (EMC norms)

    Equipment protection against electrostatic discharges

    Cautions to avoid equipment damage User Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 21/362

  • 1.1 Declaration of conformity to CE marking and Countries List

    Indication of the countries where the equipment is intended to be used: Austria (AT) - Belgium (BE) - Bulgaria (BG) - Switzerland/Liechtenstein (CH) - Cyprus (CY) - Czech Republic (CZ) - Germany (DE) - Denmark (DK) - Estonia (EE) - Finland (FI) - France (FR) - Greece (GR) - Hungary (HU) Italy (IT) - Ireland (IE) - Iceland (IS) - Lithuania (LT) Luxembourg (LU) - Latvia (LV) - Malta (MT) - Netherlands (NL) - Norway (NO) Poland (PL) Portugal (PT) - Romania (RO) Spain (SP) - Sweden (SE) - Slovenia (SI) - Slovak Republic (SK) -United Kingdom (UK)

    Indication of the intended use of the equipment: Point to Point PDH/Ethernet Transport radio LinkUser Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 122/362

  • 1.2 Specific label for MPR equipment

    The label is sticked on the MSS-1c and on the MPT-HC/MPT-MC.

    Field Field Name Note

    A Alcatel-Lucent Logo

    B Equipment acronym

    C Power Supply range See NB 1 for MSS-1cSee NB 2 for MPT-HCSee NB 3 for MPT-MCSee NB 4 for MPT-HC V2

    D Current range

    E European Community Logo

    F Not harmonized frequency logo

    G WEEE Logo

    H Electrostatic Device Logo

    NB 1: 38.4 V / - 57.6 V; 3.3 A max.

    NB 2: 28 V / - 58 V; 1.6 A / 0.8 A

    NB 3: 28 V / - 58 V; 1.6 A / 0.8 A

    NB 4: 28 V / - 58 V; 1.5 A / 0.7 A

    1.3 Applicable standards and recommendations

    1999/5/CE of 09 March 1999

    Safety: EN 60950, EN 60825-1, EN 60825-2, EN 50385

    EMC: EN 301 489-1, EN 301 489-4

    Spectrum: EN 302 217-2-2 User Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 23/362

  • 1.4 Safety Rules

    Equipment intended for installation in Restricted Access Location

    Equipment is only to be accessed by trained service personnel

    1.4.1 General Rules

    Before carrying out any installation, turn-on, tests or operation and maintenance operations, read carefully the related sections of this Manual, in particular:

    Hardware Installation

    Commissioning

    Maintenance and Upgrade

    Observe safety rules

    When equipment is operating nobody is allowed to have access inside on the equipment parts which are protected with Cover Plate Shields removable with tools.

    In case of absolute need to have access inside, on the equipment parts when it is operating this is allowed exclusively to service personnel, where for Service Personnel or Technical assistance is meant:

    "personnel which has adequate Technical Knowledge and experience necessary to be aware of the danger that he might find in carrying out an operation and of the necessary measure-ments to reduce danger to minimum for him and for others".

    The Service Personnel can only replace the faulty units with spare parts.

    The Service Personnel is not allowed to repair: hence the access to the parts no specified is not permitted.

    The keys and/or the tools used to open doors, hinged covers to remove parts which give access to compartments in which are present high dangerous voltages must belong exclusively to the service personnel.

    For the eventual cleaning of the external parts of the equipment, absolutely do not use any inflam-mable substance or substances which in some way may alter the markings, inscriptions ect.

    It is recommended to use a slightly wet cleaning cloth.

    The Safety Rules stated in the handbook describe the operations and/or precautions to observe to safe-guard service personnel during the working phases and to guarantee equipment safety, i.e., not exposing persons, animals, things to the risk of being injured/damaged.

    Whenever the safety protection features have been impaired, REMOVE POWER.User Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 124/362

  • To cut off power proceed to switch off the power supply units as well as cut off power station upstream (rack or station distribution frame).

    The safety rules described in this handbook are distinguished by the following symbol and statement:

    1.4.2 Labels Indicating Danger, Forbiddance, Command

    It is of utmost importance to follow the instructions printed on the labels affixed to the units and assemblies.

    dangerous electrical voltages

    harmful optical signals

    risk of explosion

    moving mechanical parts

    heat-radiating Mechanical Parts

    microwave radiations

    Pay attention to the information stated in the following, and proceed as instructed.

    The symbols presented in following paragraphs are all the possible symbols that could be present on Alca-tel-Lucent equipment, but are not all necessarily present on the equipment this handbook refers to.

    Dangerous Electrical Voltages

    [1] Labeling

    The following warning label is affixed next to dangerous voltages (>42.4 Vp; >60 Vdc).

    If it is a Class 1 equipment connected to mains, then the label associated to it will state that the equip-ment will have to be grounded before connecting it to the power supply voltage, e.g.:

    NoteUser Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 25/362

  • [2] Safety instructions

    DANGER! Possibility of personal injury:

    Carefully observe the specific procedures for installation / turn-up and commissioning / maintenance of equipment parts where D.C. power is present, described in the relevant installation / turn-up and commissioning / maintenance documents and the following general rules:

    Personal injury can be caused by -48VDC. Avoid touching powered terminals with any exposed part of your body.

    Short circuiting, low-voltage, low-impedance, DC circuits can cause severe arcing that can result in burns and/or eye damage. Remove rings, watches, and other metal jewelry before working with primary circuits. Exercise caution to avoid shorting power input terminals.

    Risks of Explosions: labeling and safety instructions

    This risk is present when batteries are used, and it is signaled by the following label:

    Therefore, slits or apertures are made to let air circulate freely and allow dangerous gasses to down flow (battery-emitted hydrogen). A 417-IEC-5641 Norm. compliant label is affixed next to it indicating that the openings must not be covered up.

    Moving Mechanical Parts: labeling and safety instructions

    The following warning label is affixed next to fans or other moving mechanical parts:

    Before carrying out any maintenance operation see that all the moving mechanical parts have been stopped.User Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 126/362

  • Equipment connection to earth

    Terminals for equipment connection to earth , to be done according to international safety standards, are pointed out by the suitable symbol:

    The position of earth connection terminals is specified in the Hardware Installation section.

    Heat-radiating Mechanical Parts: labeling and safety instructions

    The presence of heat-radiating mechanical parts is indicated by the following warning label in compliancy with IEC 417 Norm, Fig.5041:

    DANGER! Possibility of personal injury:

    Carefully observe the specific procedures for installation / turn-up and commissioning / maintenance of equipment parts where heat-radiating mechanical parts are present, described in the relevant installation / turn-up and commissioning / maintenance documents and the following general rule:

    Personal injury can be caused by heat. Avoid touching powered terminals with any exposed part of your body.

    Optical safety

    The equipment contains Class 1 laser component according to IEC 60825-1 (par. 5).

    CLASS 1 LASER PRODUCT

    The laser source is placed in the optional SFP plug-in, which has to be installed in the MSS-1c. The laser source is placed in the left side of the SFP plug-in.

    According to the IEC 60825-1 the explanatory label is not sticked on the equipment due to the lack of space.User Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 27/362

  • Microwave radiations (EMF norms)

    Equipment emitting RF power (Reminder from site preparation procedure):

    The site must be compliant with ICNIRP guidelines or local regulation if more restrictive.

    The following rules should be strictly applied by Customer:

    Non authorized persons should not enter the compliance boundaries, if any, for the general public.

    Compliance RF boundaries, if any, related to Electro Magnetic Field exposure must be marked.

    Workers should be allowed to switch-off the power if they have to operate inside compliance bound-aries.

    Assure good cable connection.

    Install the antenna as high as possible from floor or area with public access (if possible the cylinder delimitating the compliance boundaries, if any, or the cylinder corresponding to the transmission area directly in front of antenna with the same diameter as the antenna, more than 2 meters high).

    Install the antenna as far as possible from other existing equipment emitting RF power.

    Anyway remind that someone standing in front of the 9500 MPR antenna may cause traffic shutdown.

    Place the relevant stickers:

    EMF emission warning sign

    On the site when applicable (when people can cross the compliance boundaries and/or the transmission area of the antenna, i.e. roof top installation)

    Warning label "Do not stand on the antenna axis"

    On the mast (front side)

    EMF emission warning sign (Yellow and black) to be placed at bottom of antenna, visible by someone moving in front of the antenna (roof top installation)

    On the antenna (rear side)

    EMF emission warning sign, placed on the antenna. User Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 128/362

  • 1.5 Electromagnetic Compatibility (EMC norms)

    The equipment's EMC norms depend on the type of installation being carried out (cable termination, grounding etc.,) and on the operating conditions (equipment, setting options of the electrical/electronic units, presence of dummy covers, etc.).

    Before carrying out any installation, turn-on, tests & operation and maintenance operations, read carefully the related sections of this Manual, in particular:

    Hardware Installation

    Maintenance and Upgrade

    The norms set down to guarantee EMC compatibility, are distinguished inside this Manual by the symbol and term:

    EMC Norms

    [1] EMC General Norms - Installation

    All connections (towards the external source of the equipment) made with shielded cables use only cables and connectors suggested in this Manual or in the relevant Plant Documentation, or those specified in the Customer's "Installation Norms" (or similar documents)

    Shielded cables must be suitably terminated

    Install filters outside the equipment as required

    Ground connect the equipment utilizing a conductor with proper diameter and impedance

    Mount shields (if utilized), previously positioned during the installation phase, but not before having cleaned and degrease it

    Before inserting the shielded unit proceed to clean and degrease all peripheral surfaces (con-tact springs and connection points, etc.)

    Screw fasten the units to the subrack

    To correctly install EMC compatible equipment follow the instructions given

    [2] EMC General Norms - Turn-on, Tests & Operation

    Preset the electrical units as required to guarantee EMC compatibility

    Check that the equipment is operating with all the shields properly positioned (dummy covers, ESD connector protections, etc.)

    To properly use EMC compatible equipment observe the information given

    [3] EMC General Norms - Maintenance

    Before inserting the shielded unit, which will replace the faulty or modified unit, proceed to clean and degrease all peripheral surfaces (contact springs and connection points, etc.)

    Clean the dummy covers of the spare units as well

    Screw fasten the units to the subrack. User Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 29/362

  • 1.6 Equipment protection against electrostatic discharges

    Before removing the ESD protections from the monitors, connectors etc., observe the precautionary mea-sures stated. Make sure that the ESD protections have been replaced and after having terminated the maintenance and monitoring operations.

    Most electronic devices are sensitive to electrostatic discharges, to this concern the following warning labels have been affixed:

    Observe the precautionary measures stated when having to touch the electronic parts during the instal-lation/maintenance phases.

    Workers are supplied with anti static protection devices consisting of:

    an elasticized band worn around the wrist a coiled cord connected to the elasticized band and to the stud on the subrack

    1.7 Cautions to avoid equipment damage

    a. Anti static protection device kit

    Whenever is necessary to handle spare parts and cards out of their own box, this kit (Illustration below) must be always warn and its termination must be connected to a grounded structure, to avoid the possible damage of the electronic devices for electrostatic discharges.

    Anti static protection device kit

    b. Screw fixingIn normal operation conditions, all screws (for unit box closing, cable fixing, etc.) must be always tightened to avoid item detachment and to ensure the equipment EMI-EMC performance.The screw tightening torque must be:

    2.8 kg x cm (0.28 Newton x m) 10 %2.4317 in lb (0.2026 ft lb) 10 %

    Exceeding this value may result in screw breaking.

    c. MSS-1c-ODU cable disconnection / connectionBefore to disconnect or connect the MSS-1c-ODU cable (at MSS-1c or ODU side) switch off the cor-responding MSS-1c Unit.User Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 130/362

  • 1.8 Waste from Electrical and Electronic Equipment (WEEE)

    This product must be selectively collected and treated. Treatment applied at end of life of the product shall comply with the applicable national laws implementing directive on waste electrical and electronic equip-ment (WEEE).

    The use of the crossed-out wheeled bin symbol indicates that the product is subject to separate col-lection and is not to be treated as general household waste (only for B2C equipment).

    Separate collection and recycling of waste equipment at the time of disposal contribute to avoid possible negative effects on the environment and on human health.User Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 1 31/362

  • User Manual

    Safety, EMC, EMF, ESD Norms and Equipment Label-

    9500 MPR-E Rel. 3.3.0

    3DB18961DAAA Issue 132/362

  • 2 Product information and planningHere below the topics of this chapter are listed:

    9500 Family overview (par. 2.1 on page 35) 9500 MPR System Family (par. 2.1.1 on page 39) Family elements described in this User Manual (par. 2.1.2 on page 40) MSS-1c (par. 2.1.3 on page 40) MPT-HC (par. 2.1.4 on page 41) MPT-HC V2 (par. 2.1.5 on page 42) MPT-MC (par. 2.1.6 on page 42) MSS-1c to MPT-HC interconnection (par. 2.1.7 on page 43) MSS-1c to MPT-HC V2 interconnection (par. 2.1.8 on page 45) MSS-1c to MPT-MC interconnection (par. 2.1.9 on page 47) Antennas (par. 2.1.10 on page 47)

    Radio capacity, channelling and modulation (MPT-HC/MPT-HC V2/MPT-MC) (par. 2.2 on page 48)

    Standard Features (par. 2.3 on page 51)

    Radio Configurations (par. 2.4 on page 51)

    Typical System Configurations (par. 2.5 on page 52)

    Environmental and Electrical Characteristics (par. 2.6 on page 53) General characteristics (MSS-1c) (par. 2.6.1 on page 53) General characteristics (MPT-HC/MPT-HC V2/MPT-MC) (par. 2.6.2 on page 54) MPT-MC characteristics (par. 2.6.3 on page 55)

    6 to 13 GHz (par. 2.6.3.1 on page 55) 15 to 38 GHz (par. 2.6.3.2 on page 55)

    MPT-HC/MPT-HC V2 characteristics (par. 2.6.4 on page 56) 5.8 to 13 GHz (par. 2.6.4.1 on page 56) 15 to 38 GHz (par. 2.6.4.2 on page 57)

    Radio