(800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · •...

72
www.RenewAire.com (800) 627-4499 Fax: (608) 221-2824 4510 Helgesen Drive Madison, Wisconsin 53718 USA In CANADA www.MitsubishiElectric.ca (905) 475-8989 Fax: (905) 475-5231 In MEXICO, CENTRAL and SOUTH AMERICA and the CARIBBEAN www.Soler-Palau.com.mx 52 (222) 2 233 911 Fax: 52 (222) 2 233 914

Transcript of (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · •...

Page 1: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com • (800) 627-4499 • Fax: (608) 221-28244510 Helgesen Drive • Madison, Wisconsin 53718 USA

In CANADAwww.MitsubishiElectric.ca • (905) 475-8989 • Fax: (905) 475-5231

In MEXICO, CENTRAL and SOUTH AMERICA and the CARIBBEANwww.Soler-Palau.com.mx • 52 (222) 2 233 911 • Fax: 52 (222) 2 233 914

Page 2: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

Energy Recovery Ventilation: the proven

advantages of heat and humidity transfer

Improves Indoor Air QualityBy providing simultaneous exhaust and fresh air supply, RenewAire reduces the concentration of harmful pollutants in indoor air - an absolute must in schools, offices and smoking environments.

Meets Ventilation Codes for Air ExchangeProvides ample ventilation to meet ASHRAE 62 and the International Mechanical Code that now requires two to three more air exchanges than in the past.

Controls Excess MoistureUnlike conventional ventilation or basic heat exchangers, RenewAire moderates not only the temperature but the humidity content of incoming air, limiting humidity swings and associated biologic growths.

Optimum Cold Weather PerformanceRecaptures heat otherwise lost to exhaust air while controlling humidity extremes. This greatly reduces the demand on heating equipment - lowering both initial costs and energy bills. Also protects heating coils from freeze damage.

Optimum Warm Weather PerformancePre-cools and dehumidifies the fresh airstream by transfer of heat and humidity to the exhaust airstream. This greatly reduces air conditioning demand - lowering both initial costs and energy bills. On retrofits, the ventilation rate of exisitng A/C equipment can be as much as doubled.

Energy Saved = Dollars SavedRenewAire’s all-weather performance can cut annual energy bills for heating, cooling and dehumidification of ventilation air by 50% or more.

Indoor Air Quality Problems Solved!

Ideal for Hot or Cold Environments

Catalog Page Reference2 Residential Products4 BR705 BR1306 EV707 EV1308 EV2009 EV30010 Commercial Indoor Products12 EV450IN14 HE1XINH16 HE1XINV18 HE2XINH20 HE2XINV22 HE3XINH24 HE3XINV26 HE4XINH28 HE4XINV30 HE6XIN32 HE8XIN34 Commercial Outdoor Products

36 EV450RT38 HE1XRT40 HE1XRTC42 HE2XRT44 HE2XRTC46 HE3XRT48 HE3XRTC50 HE4XRT52 HE4XRTC54 HE6XRT56 HE8XRT58 Applied Products60 CA-Series62 PA-Series64 Commercial Controls66 HVI Certified67 AHRI Certified67 CA/PA Model

Number Guide68 EV/HE Model

Number Guide69 Company History

For Technical Support E-mail: [email protected] Place an Order E-mail: [email protected]

Page 3: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

Why RenewAirE?

The Static-Plate Core is the Key!Since the early 1980’s, RenewAire has pioneered the use of the patented Lossnay (Registered trademark of Mitsubishi Electric Corporation) exchange core throughout the Americas. Listed below are some of the many reasons why this technology has become the ERV system preferred by leading HVAC professionals around the world.

Positive Airstream SeparationIn the RenewAire core, fresh air never comes in contact with exhaust air passages. Hydroscopic resin plates separate the two airstreams so effectively that AHRI certifies zero exhaust air transfer at normal, balanced operating conditions. As a result, RenewAire is perfect for controlled exhaust applications such as toilet areas, as well as for food service and health care occupancies.

No Condensate or Active DefrostDirect water vapor transfer, driven by vapor pressure, eliminates condensation - and frosting - in virtually all applications and climate zones. No condensation allows for closer plate spacing, resulting in higher efficiencies and easier installations. It also means no need for the dampers or electrical defrost elements that reduce ventilation and rob energy efficiency in competing technologies.

Maintenance - Nothing Could Be EasierThe scheduled maintenance for RenewAire is so simple, it can be performed by any janitorial staff. No expensive service contracts are necessary because there is no wheel disassembly and washing, no seal or belt adjustments and no complex controls to calibrate. The result is the lowest maintenance cost of any ERV.

The Unbeatable RenewAire WarrantyAn investment in RenewAire is protected by a 10-year core warranty (2 years on balance of the unit). This commitment - twice as long as coverage on the best wheel products - speaks volumes about RenewAire’s reliability, durability and consistently high performance.

Award-Winning Service and SupportRenewAire’s team of professionals knows ERV. And our nationwide network of Sales Reps and quality Distributors are ready to serve you locally. When you call our support number, you’ll talk to a knowledgeable factory expert - someone who knows not only our product line, but the best ways to integrate RenewAire with your preferred lines of heating and air conditioning equipment.

INSIDEFresh Air to Room

OUTSIDEStale Room Air

(exhausted to outside)

Stale Room Air Outside Air

Fixed Partitionand Spacer Plates(proprietary resincomposite media)

RenewAire’s remarkable performance is independently certified by:

G5 Enhanced Humidity Transfer

RenewAire is proud to introduce the fifth generation energy

recovery ventilation (ERV) core.

Over 22% more humidity transfer • at AHRI summer conditions

reduced pressure drop - among • the lowest for static-plate ERV

HE1X = 0.65” @ 750 SCFM EV450 = 0.6” @ 450 SCFM

Try RenewAire’s ERV Calculation Software

at www.ervcalc.renewaire.com

Page 4: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-28242

Residential/Small

Commercial Products

Commercial quality, ducted equipment • sized to meet required ventilation rates for homes and small commercial buildings.

Static-plate technology makes total energy • savings practical for small-capacity systems.

May be mounted in any orientation.•

Quiet, powerful blowers eliminate the need • for air balancing in most applications.

Positive airstream separation that is • critical for smoking environments and bathroom exhaust.

No condensate pan or drain required.•

Easiest maintenance of any ERV.•

Performance certified by HVI.•

Ten year core warranty.•

primary control for EV70, • EV130, EV200 & EV300 runs unit an adjustable • amount of time each hour two wire, low voltage • connection to ERV

PTL Controlpush button control turns on • unit from bathrooms or other intermittent exhaust locations 20 minute run-time • with one touch push 2x for 40 or • 3x for 60 minutes two wire, low voltage • connection to PTL Control

PBL Controlalternate primary control for • EV70, EV130, EV200 & EV300 wires to EV unit and either • thermostat or furnace control to turn on furnace blower six wire, low voltage • connection

FM Control

EA: Exhaust Air to outdoors

FA: Fresh Air to insideRA: Room Air to be exhaustedOA: Outdoor Air intakeCentral Exhaust - Use EV Series

General Exhaust - EV Series (or BR Series mounted to furnace return air which requires furnace blower interconnect)

NOTE: ERV Blower may be operated separately from Furnace Blower

NOTE: ERV Blower may be operated separately from Furnace Blower

(See manual for additional installation methods.)

Page 5: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com3

Part I - General

A. Product Specification

1. Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology.

B. Quality Assurance

1. The energy recovery ventilator shall be Certified by the Home Ventilating Institute (HVI) under CSA 439. Both a heating and a cooling test must be run to demonstrate year round energy recovery.

2. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 25 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system. The method of test shall be UL Standard 723.

3. Unit shall be Listed under UL 1812 Standard for Ducted Air to Air Heat Exchangers. The unit must pass commercial flammability requirements and shall not be labeled “For Residential Use Only”.

4. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase.

Part II – Performance

A. Energy TransferThe ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air.

B. Passive Frost ControlThe ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10°F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed.

C. Continuous VentilationUnit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions.

D. Positive Airstream SeparationWater vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by “porous plate” mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages and airstreams shall not mix.

E. Laminar FlowAirflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material.

Part III – Product

A. Construction

1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts.

2. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate.

3. The unit case shall be constructed of 24-gauge steel, with lapped corners and zinc plated screw fasteners. The case shall be finished with textured, powder coat paint.

4. Access doors shall provide easy access to blowers, ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets.

5. Case walls and doors shall be fully insulated with 1 inch, expanded polystyrene foam insulation faced with a cleanable foil face on all exposed surfaces.

6. The ERV cores shall be protected by a MERV-8 rated, spun polyester, disposable filter in both airstreams.

7. The unit shall have a line cord power connection and be supplied with an internal 24 VAC transformer and relay.

8. Standby power draw shall not exceed 1 Watt for the unit along with an optional automatic control. B. Options (Select options based on application requirements)

1. For BR-Series: Through the wall kit and duct collar kit (automatic control is built into the unit standard).

2. For EV-Series: Controls including proportional run time, push button and furnace interlock and a variety of weather hoods.

Part IV – Installation

A. Unit Location

1. Locate and orient unit to provide the shortest and most straight duct connections. Provide service clearances as indicated on the plans. Locate units distant from sound critical occupancies.

2. Use integral mounting flange and hanging bar system to mount the unit to a structurally suitable surface. The units may be mounted in any orientation.

B. Vibration Isolation

1. Utilize factory supplied vibration isolation kit following instructions.

2. Provide flexible duct connections at unit duct flanges.

C. Duct Design

1. All ductwork shall be designed, constructed, supported and sealed in accordance with SMACNA HVAC Duct Construction Standards and pressure classifications.

2. At a minimum all duct runs to the outdoors shall be thermally insulated at levels appropriate to the local climate. A continuous vapor barrier shall also be provided on warm surface of the insulation.

D. Sound Control

1. To control sound radiated from the unit: a. Provide acoustic treatment in mechanical room walls and ceilings.

2. To control sound associated with the two blower outlets: a. Utilize insulated, flexible duct. b. In sound critical applications provide increased duct sizing and consider the use of sound attenuators.

E. Test and Balancing

1. Test and Balancing may not begin until 100% of the installation is complete and fully functional.

2. Follow National Comfort Institute (NCI) air test and balance procedures specific to Heat Recovery Ventilator Balancing Procedure including standard reports to the owner’s representative.

Residential Energy Recovery Ventilators: BR70, BR130, EV70, EV130, EV200 and EV300

Page 6: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-28244

BR70Specifications

G4 Performance

Dimensions

Indoor UnitVentilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 40-70 CFM

Number Motors: One, 0.08 hp

V HZ Phase Input Watts FLA

120 60 Single 94 @ 69 CFM 0.9

Control Voltage: 24 VAC

Filters: MERV 8, spun polyester media. 7 1/2” x 10 1/2” x 1”

Weight: 39 lbs (unit), 50 lbs (in carton)

Shipping Dimensions: 21 1/2”W x 29”L x 14 1/2”H

Options: Thru-the-Wall Kit Duct Collar Kit

Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer*

35 0.50 84 75/60

51 0.40 80 71/56

63 0.30 77 68/53

79 0.20 73 64/48

90 0.10 70 61/45

* (See HVI certification report on page 66 for complete certified rating).

EA: Exhaust Air to outdoorsOA: Outdoor Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside

TW: Thru WallDH: Duct Hung

18 1/4

54 1/2

27 1/8

36" LINE CORD

24 VAC CONTROL TERMINAL

18 1/2SERVICE

AREA

RIGHTVIEW

SIDE VIEW

BOTTOM VIEW(DOOR REMOVED)

10 5/8

2

1 1/8

EA (TW)FA (DH)

OA (TW)RA (DH)

TOP VIEW

6

17 5/8CUT HOLE IN DUCT(MINIMUM SIZE)

OA (TW)RA (DH) EA (TW)

FA (DH)

RA (TW)OA (DH)

FA (TW)EA (DH)

8 DIA6 DIA

PROPORTIONALRUNTIME

CONTROL

Page 7: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com5

BR130Specifications

G4 Performance

Dimensions

Indoor UnitVentilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 50-140 CFM

Unit may be mounted in any orientation

Number Motors: One, 0.1 hp

V HZ Phase Input Watts FLA

120 60 Single 121 @ 124 CFM 1.3

Control Voltage: Built in proportional runtime control and switched terminals for furnace / AC interconnect

Filters: MERV 8, spun polyester media. 10 1/2” x 10 1/2” x 1”

Weight: 49 lbs (unit), 60 lbs (in carton)

Shipping Dimensions: 21”W x 32”L x 17 1/2”H

Options: Thru-the-Wall Kit Duct Collar Kit

Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer*

52 0.70 83 75/60

69 0.60 80 72/57

94 0.50 76 67/52

113 0.40 73 64/48

132 0.30 70 60/44

141 0.20 68 59/43

148 0.10 67 57/41

* (See HVI certification report on page 66 for complete certified rating).

18 1/4

54 1/2

6 1/8 4 3/4

13 3/8

30 7/8

36" LINE CORD

24 VAC CONTROL TERMINAL 18 1/2

SERVICEAREA

RIGHTVIEW

SIDE VIEW

BOTTOM VIEW(DOOR REMOVED)

2

1 1/8

EA (TW)FA (DH)

OA (TW)RA (DH)

TOP VIEW

CUT HOLE IN DUCT(MINIMUM SIZE)

20 1/2

6

OA (TW)RA (DH) EA (TW)

FA (DH)

FA (TW)EA (DH)

OA (DH)RA (TW) 6 DIA

8 DIA

PROPORTIONALRUNTIME

CONTROL

EA: Exhaust Air to outdoorsOA: Outdoor Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside

TW: Thru WallDH: Duct Hung

Page 8: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

EV70Specifications

G4 Performance

Dimensions

Indoor UnitVentilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 40-70 CFM

Unit may be mounted in any orientation

Number Motors: One, 0.08 hp

V HZ Phase Input Watts FLA

120 60 Single 94 @ 69 CFM 0.9

Control Voltage: 24 VAC

Filters: MERV 8, spun polyester media. 7 1/2” x 10 1/2” x 1”

Weight: 39 lbs (unit), 48 lbs (in carton)

Shipping Dimensions: 21 1/2”W x 29”L x 14 1/2”H

Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH24 - Dehumidistat Control Wall Caps

* (See HVI certification report on page 66 for complete certified rating).

20 1

/8"

27 7/8" Service Access

RA

OA

FA

EA

BlowersInterlock Switch

Energy Transfer CoreFilters

34" Line Cord

24 Volt ACControl Terminal

Line Cord

4 1/

2"5

1/2"

9 1/

8"

5 1/

2"

6"6"

8 1/

8"

6"8"

FRONT VIEW RIGHT VIEW

TOP VIEW10 1/8"

4 1/

8"

25 1/8"

Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer*

46 0.40 81 74/60

59 0.30 78 71/57

73 0.20 74 68/53

86 0.10 71 64/49

EA: Exhaust Air to outdoorsOA: Outdoor Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside

(800) 627-4499 • Fax: (608) 221-28246

Page 9: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

EV130Specifications

G4 Performance

Dimensions

Indoor UnitVentilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 50-140 CFM

Unit may be mounted in any orientation

Number Motors: One, 0.1 hp

V HZ Phase Input Watts FLA

120 60 Single 121 @ 124 CFM 1.2

Control Voltage: 24 VAC

Filters: MERV 8, spun polyester media. 10 1/2” x 10 1/2” x 1”

Weight: 49 lbs (unit), 58 lbs (in carton)

Shipping Dimensions: 21”W x 32”L x 17 1/2”H

Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH24 - Dehumidistat Control Wall Caps

Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer*

52 0.70 83 75/60

69 0.60 80 72/57

94 0.50 76 67/52

113 0.40 73 64/48

132 0.30 70 60/44

141 0.20 68 59/43

148 0.10 67 57/41

* (See HVI certification report on page 66 for complete certified rating).

13"

20 1

/8"

30 5/8" Service Access

RA

OA

FA

EA

BlowersInterlock Switch

Energy Transfer CoreFilters

34" Line Cord

24 Volt ACControl Terminal

Line Cord

6 3/

8"

4 1/

8"

5 1/

2"9

1/8"

5 1/

2"

6"6"

8 1/

8"

6"8"

28 3/4"

FRONT VIEW RIGHT VIEW

TOP VIEW

EA: Exhaust Air to outdoorsOA: Outdoor Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside

www.RenewAire.com7

Page 10: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-28248

EV200Specifications

G4 Performance

Dimensions

Indoor UnitVentilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 100-200 CFM

Number Motors: One, 0.1 hp

V HZ Phase Input Watts FLA

120 60 Single 157 @ 181 CFM 1.5

Control Voltage: 24 VAC

Filters: MERV 8, spun polyester media. 10 1/2” x 21 3/4” x 1”

Weight: 70 lbs (unit), 82 lbs (in carton)

Shipping Dimensions: 21 1/2”W x 32”L x 29”H

Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH24 - Dehumidistat Control Wall Caps

Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer*

122 0.70 82 74/59

149 0.65 80 72/56

168 0.50 79 70/55

176 0.40 78 69/54

186 0.30 77 68/53

192 0.20 77 68/52

200 0.10 76 67/52

* (See HVI certification report on page 66 for complete certified rating).

Blowers

34" Line Cord

Interlock Switch

Energy Transfer CoreFilters

24 Volt ACControl Terminal

Line Cord

RA

OA

FA

EA

23 7/8"

20 1

/8"

41 1/2" Service Access

11 7

/8"

11 7

/8"

5 1/

2"5

1/2"

9 1/

8"

6"6"

8 1/

8"

6"8"

28 3/4"

FRONT VIEW RIGHT VIEW

TOP VIEW

EA: Exhaust Air to outdoorsOA: Outdoor Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside

Page 11: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com9

EV300Specifications

G4 Performance

Dimensions

Indoor UnitVentilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 150-300 CFM

Number Motors: One, 0.2 hp

V HZ Phase Input Watts FLA

120 60 Single 310 @ 293 CFM 3.3

Control Voltage: 24 VAC

Filters: MERV 8, spun polyester media. 10 1/2” x 21 3/4” x 1”

Weight: 72 lbs (unit), 85 lbs (in carton)

Shipping Dimensions: 21 1/2”W x 32”L x 29”H

Options: PTL - Percentage Timer Control PBL - Push Button Point-of-Use Controls FM - Percentage Timer Control with Furnace Interlock DH24 - Dehumidistat Control 8” Wall Caps

Airflow CFM ESP in H20 Temp EFF% Total EFF% Winter/Summer*

155 1.0 80 70/51

199 0.9 76 67/48

249 0.8 72 62/44

268 0.7 71 61/42

289 0.6 69 58/39

300 0.5 68 57/38

310 0.4 67 56/37

* (See HVI certification report on page 66 for complete certified rating).

Blowers

34" Line Cord

Interlock Switch

Energy Transfer CoreFilters

24 Volt ACControl

Terminal

Line Cord

RA

OA

FA

EA

23 7/8"

20 1/8"

41 1/2" Service Access

9 3/4"10"

5 1/2"

5 1/2"

9 1/8"

5 1/2"

5 1/2"

9 1/8"

7 3/8"

8 3/4"

To Fit 8" Duct

FRONT VIEW

28 3/4"

TOP VIEW

RIGHT VIEW

EA: Exhaust Air to outdoorsOA: Outdoor Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside

Page 12: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282410

Commercial

INDOOR Products

Horizontal and v• ertical configuration.

Wide range of airflow and static capacities.•

AHRI certified per• formance data for efficiency and cross leakage.

UL tested fla• mmability and smoke generation that meets NFPA 90A and 90B test standards for commercial applications.

Easy installation and service.•

Ten year core warranty.•

EA: Exhaust Air to outdoorsOA: Outdoor Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside

RenewAire means Trouble-Free ERV.

Page 13: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com11

Part I - General

A. Product Specification

1. Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology.

B. Quality Assurance

1. The energy recovery cores used in these products shall be third party Certified by AHRI under its Standard 1060 for Energy Recovery Ventilators. AHRI published certifications shall confirm manufacture’s published performance for airflow, static pressure, temperature and total effectiveness, purge air (OACF) and exhaust air leakage (EATR). Products that are not currently AHRI Certified will not be accepted.

2. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 25 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system. The method of test shall be UL Standard 723.

3. Unit shall be Listed under UL 1812 Standard for Ducted Air to Air Heat Exchangers. (Note that a few low volume product or product configurations are not UL Listed.)

4. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase.

Part II – Performance

A. Energy TransferThe ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air.

B. Passive Frost ControlThe ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10°F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed.

C. Continuous VentilationUnit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions.

D. Positive Airstream SeparationWater vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by “porous plate” mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages and airstreams shall not mix.

E. Laminar FlowAirflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material.

Part III – Product

A. Construction

1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts.

2. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate.

3. The unit case shall be constructed of G90 galvanized, 20-gauge steel, with lapped corners and zinc plated screw fasteners.

4. Access doors shall provide easy access to blowers, ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets.

5. Case walls and doors shall be insulated with 1 inch, 4 pound density, foil/scrim faced, high-density fiberglass board insulation, providing a cleanable surface and eliminating the possibility of exposing the fresh air to glass fibers.

6. The ERV cores shall be protected by a MERV-8 rated, 2” nominal, pleated, disposable filter in both airstreams.

7. Unit shall have single-point power connection and a single-point 24 VAC contactor control connection (except Inverter Ready units that have terminal connections for an independent inverter for each airstream).

8. Blower motors shall be EPACT compliant for energy efficiency and be thermally protected or supplied with external starters.

9. Blowers shall be quiet running, forward curve type and be either direct drive or belt drive. HE6X and HE8X units use backward incline, belt drive blower packages. Belt drive motors shall be provided with adjustable pulleys and motor mounts allowing for proper belt tensioning.

B. Options (Select options based on application requirements.)

1. Provide unit and duct connection orientation per project schedule.

2. Provide double wall construction with 24-gauge galvanized steel liner.

3. Units are available single or three phase at a full range of operating voltages. See project schedule.

4. Provide motor horsepower as specified in project schedule.

5. Provide “inverter-ready” units which include shielded power wiring and terminal connections for inverters (inverters provided and installed by others).

6. Provide factory installed fused disconnects.

7. Provide factory installed non-fused disconnects.

8. Provide factory installed transformer/relay package to supply a 24 VAC power source.

9. Provide factory installed filter monitors for each airstream.

Packaged Indoor Energy Recovery Ventilators: EV450IN, HE1XIN, HE2XIN, HE3XIN, HE4XIN, HE6XIN, HE8XIN

Page 14: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282412

EV450IN

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 200-500 CFM

AHRI 1060 Certified Core: One L85

Airflow Rating Points (for AHRI): 450 CFM and 338 CFM

Motors: One, 0.6 hp (Single Phase) One, 0.5hp (Three Phase)

V HZ Phase FLA

115 60 Single 7.0

208-230 60 Single 3.5

277 60 Single 2.4

208-230 60 Three 1.7-1.5

460 60 Three 0.8

Control Voltage: 24 VAC

Filters: Two total, MERV 8, 2” pleated, 14” x 20” nominal size

Weight: 141 lbs (unit), 160 lbs (in carton), up to 3 units on 50 lb pallet

Shipping Dimensions: 37 1/2” W x 48” L x 17” H

Options: 45EVHB - Hanging Bracket, Foot Kit 45EVDF - Rectangular 12” x 8” Flange Kit (2 in kit) 45EVT10 - 10” Round Transition Kit (2 in kit)

Airflow CFM

ESP in H20

Watts1P 3P

Temp EFF%

Total EFF%Winter/Summer*

225 1.25 335 181 81 76/66

338 1.00 420 278 77 71/61

380 0.90 470 340 75 69/59

450 0.65 550 430 73 66/56

540 0.25 640 540 70 62/52

575 0.00 690 610 69 61/51

600 -0.25 735 664 68 60/50

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

Indoor Unit Specifications

G5 Performance

Page 15: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com13

EV

450

INU

nit

Dim

en

sio

ns

16 1/8"

5 3/8"

20 3/8"24 7/8"

11 5/8"

1"13 1

/4"

35 1/4"

33 7/8"

36 3/8"

4 1/4"16 1/8"

20 1/4"32"

10"

36 3/8"

2 1/

8"18

"44

1/8

"6

1/2"

1 1/4"

16"

34 1

/8"

Ser

vice

Are

a

8"2

1/8"

8"8"

8"8"

FRO

NT

VIE

W

TOP

VIE

W

Pow

er S

uppl

y E

ntry

7/8"

Dia

.

Filte

r Acc

ess:

Hin

ged

and

Latc

hed

Doo

r

All

othe

r Acc

ess:

Scr

ew-a

ttach

edpa

nel

1 1/

2" C

lear

ance

requ

ired

to re

mov

e do

ors

from

hin

ges.

6 3/

8"

26 1/4"10 1/8"

Opt

iona

l 45E

VT1

0-10

" Rou

nd

Tran

sitio

n K

it S

how

nO

ptio

nal 4

5EV

DF

Rec

tang

ular

12

" X 8

" Fla

nge

Kit

Sho

wn

EA FA

OA

RA

OA

RA

FAEA

FRO

NT

VIE

W (D

oors

rem

oved

)R

IGH

T V

IEW

SLE

FT V

IEW

S2

1/8"

10"

4 1/4"16 1/8"

20 1/4"32"

36 3/8"

O10" R

OUND

11 1/8"25 1/8"

1"8

3/4"

4 1/4"16 1/8"

20 1/4"32"

3 1/4"

5 1/

4"

2 1/

8"4

3/4"

13 1/4"

Alte

rnat

eP

ower

Sup

ply

Ent

ry7/

8" D

ia.

Opt

iona

l Tra

nsiti

ons

(45E

VT1

0) s

how

nCon

trol W

ire E

ntry

7/8"

Dia

.

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 16: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282414

HE1XINHIndoor Unit

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 250-925 CFM

AHRI 1060 Certified Core: One L125-00

Airflow Rating Points (for AHRI): 750 CFM and 560 CFM

Number Motors: Two

V HZ Phase FLA Min. Cir. Amps

Max. Fuse Size

115 60 Single 8.6 19.4 25

208-230 60 Single 4.3 9.7 15

277 60 Single 2.4 5.4 15

208-230 60 Three 2.1 5.2 15

460 60 Three 1.1 2.6 15

Control Voltage: 24 VAC

Filters: Two total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 211 lbs (unit), 250 lbs (shipping weight)

Shipping Dimensions: 44” W x 56” L x 27” H

Specifications

Motor HPPhase

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

0.75 (Two DD)Single Phase

970 CFM1,490 Watts

925 CFM1,375 Watts

860 CFM1,270 Watts

795 CFM1,160 Watts

720 CFM1,030 Watts

635 CFM 950 Watts

350 CFM 750 Watts

0.75 (Two DD)Three Phase

1,030 CFM1,220 Watts

1,010 CFM1,210 Watts

975 CFM1,160 Watts

880 CFM1,050 Watts

800 CFM 990 Watts

700 CFM 850 Watts

530 CFM 720 Watts

G5 PerformanceCFM

250 500 750 1,000

80

60

40

Effe

ctiv

enes

s (%

)

SensibleWinter Total

Summer Total

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

Airflow Performance

Page 17: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com15

HE1X

INH

Un

it D

imen

sio

ns

OA

FAR

A

EA

EA

FA

Con

trol W

iring

Inle

t 7/8

" Dia

.

40 5

/8"

Min

imum

Ser

vice

Are

a(D

oors

can

be

take

n of

f hin

ges.

)

49 1

/8" C

ase

34 7

/8" C

ase

Ø12

" TY

P

FRO

NT

VIE

WLE

FT V

IEW

TOP

VIE

W

Alte

rnat

e C

ontro

l Wiri

ng In

let

7/8"

Dia

.

Pow

er W

iring

Inle

t 7/ 8

" Dia

.

Alte

rnat

e P

ower

Wiri

ng In

let

7/8"

Dia

.

20 5

/8"

50 1

/8"

Max

imum

Doo

r Ext

ensi

on

54 3

/4" O

vera

ll

9 1/

2"

28 3

/8"8 5/

8"12

7/8

"

9 5/

8"28 1

/4"36

3/8

"O

vera

ll

RIG

HT

VIE

W10 3

/8"

21 3

/4" O

vera

ll

OA

RAEA

: E

xhau

st A

ir t

o ou

tdoo

rsO

A: O

utdo

or A

ir in

take

RA:

Roo

m A

ir t

o be

exh

aust

edFA

: F

resh

Air

to

insi

de

Page 18: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282416

HE1XINV

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 250-925 CFM

AHRI 1060 Certified Core: One L125-00

Airflow Rating Points (for AHRI): 750 CFM and 560 CFM

Number Motors: Two

V HZ Phase FLA Min. Cir. Amps

Max. Fuse Size

115 60 Single 8.6 19.4 25

208-230 60 Single 4.3 9.7 15

277 60 Single 2.4 5.4 15

208-230 60 Three 2.1 5.2 15

460 60 Three 1.1 2.6 15

Control Voltage: 24 VAC

Filters: Two total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 211 lbs (unit), 250 lbs (shipping weight)

Shipping Dimensions: 44” W x 56” L x 27” H

Indoor Unit Specifications

Motor HPPhase

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

0.75 (Two DD)Single Phase

970 CFM1,490 Watts

925 CFM1,375 Watts

860 CFM1,270 Watts

795 CFM1,160 Watts

720 CFM1,030 Watts

635 CFM 950 Watts

350 CFM 750 Watts

0.75 (Two DD)Three Phase

1,030 CFM1,220 Watts

1,010 CFM1,210 Watts

975 CFM1,160 Watts

880 CFM1,050 Watts

800 CFM 990 Watts

700 CFM 850 Watts

530 CFM 720 Watts

Airflow Performance

G5 PerformanceCFM

250 500 750 1,000

80

60

40

Effe

ctiv

enes

s (%

)

SensibleWinter Total

Summer Total

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

Page 19: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com17

HE1X

INV

Un

it D

imen

sio

ns

OA

FARA

EA

RIG

HT

VIE

WFR

ON

T V

IEW

LEFT

VIE

WP

ower

Wiri

ng In

let

7/8"

Dia

.C

ontro

l Wiri

ng In

let

7/8"

Dia

.

20 5/8"

40 3

/8" O

vera

ll

21 3

/4" O

vera

ll10

3/8

"

17"41 1/2"

50 5/8"

17"41 5/8"

10 3

/8"

12 7

/8"

34 7

/8" C

ase

49 1/8" Case

51 3/8" Overall

40 5

/8"

Min

imum

Ser

vice

Are

a(D

oors

can

be

take

n of

f hin

ges.

)

50 1

/8"

Max

imum

Doo

r E

xten

sion

RA FA

OA EA

TOP

VIE

W

Ø12" TYP

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 20: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282418

HE2XINH

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 500-2,000 CFM

AHRI 1060 Certified Core: Two L125-00

Airflow Rating Points (for AHRI): 1,500 CFM and 1,120 CFM

Number Motors: Direct Drive (DD) Four, Belt Drive (BD) Two

Drive HP Volts HZ Phase FLA

Min. Cir.

Amps

Max. Fuse Size

DD 0.75

115208-230

277208-230

460

6060606060

SingleSingleSingleThreeThree

8.64.32.42.11.1

36.618.310.29.84.9

4520151515

BD 1.5

208-230208-230

460575

60606060

SingleThreeThreeThree

9.3-9.04.8-4.8

2.41.8

20.910.85.44.1

30151515

BD2

208-230208-230

460575

60606060

SingleThreeThreeThree

11.3-10.56.2-6.2

3.12.3

25.414.07.05.2

35201515

Control Voltage: 24 VAC

Filters: Four total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 414 lbs (unit), 420 lbs (shipping weight)

Shipping Dimensions: 50” W x 62” L x 41” H

Motor HP Blower RPM Nominal

Turns Open

External Static Pressure (Inches Water Column)0.0 0.25 0.5 0.75 1.0 1.25 1.5

0.75 (Four DD)

Single PhaseN/AN/A

N/AN/A

1,950 CFM2,240 Watts

1,830 CFM2,155 Watts

1,670 CFM2,020 Watts

1,400 CFM1,795 Watts

1,150 CFM1,490 Watts

700 CFM1,190 Watts

- - - -

0.75 (Four DD)

Three PhaseN/AN/A

N/AN/A

1,960 CFM2,500 Watts

1,840 CFM2,300 Watts

1,700 CFM2,125 Watts

1,600 CFM1,900 Watts

1,380 CFM1,700 Watts

1,190 CFM1,500 Watts

800 CFM1,260 Watts

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

1.5 (BD)1,0001,2301,420

4.520

1,378 0.51,694 0.91,956 1.4

1,175 0.51,550 0.91,850 1.4

900 0.41,335 0.81,680 1.2

635 0.41,125 0.71,475 1.2

- -1,000 0.71,300 1.1

- - 500 0.61,200 1.1

- - - - 930 0.9

2 (BD)1,2201,4701,660

4.520

1,681 0.92,025 1.6 - -

1,530 0.91,925 1.5 - -

1,315 0.71,750 1.42,000 2.0

1,100 0.71,575 1.31,900 1.9

975 0.61,375 1.21,750 1.8

- -1,275 1.21,570 1.7

- -1,125 1.11,475 1.7

Indoor Unit

CFM500 1,000 1,500 2,000

80

60

40

Effe

ctiv

enes

s (%

)

SensibleWinter Total

Summer Total

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

Specifications

G5 Performance

Airflow Performance

Note: Brake Horse Power (BHP) is for one blower motor package only.

Page 21: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com19

HE2X

INH

Un

it D

imen

sio

ns

EAFA

8"

OA

RA

2 7/8"21 5/8"

36 5/8"

41 1

/4"

54 7

/8" o

vera

ll

60" Service Area

33"59

" Ser

vice

Are

a

49 1

/4" c

ase

34 3/4"E

AFA

15 3/8"

LEFT

VIE

WB

elt D

riven

Ver

sion

LEFT

VIE

WD

irect

Driv

e Ve

rsio

n

FRO

NT

VIE

WR

IGH

T V

IEW

TOP

VIE

W

24" T

YP

14" typ

Filte

rs

35 1/4" Case

3 1/2"20 5/8"2 3/4"

19 5/8"

Wiri

ng E

ntry

7/8"

Dia

.

E-B

ox

RA OA

FA EA

Not

e: D

oor l

ifts

away

.

E-B

ox

Not

e: A

ll du

ct fl

ange

s ar

e 14

" x 2

4".

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 22: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282420

HE2XINVIndoor Unit Specifications

CFM500 1,000 1,500 2,000

80

60

40

Effe

ctiv

enes

s (%

)

SensibleWinter Total

Summer Total

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

G5 Performance

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 500-2,000 CFM

AHRI 1060 Certified Core: Two L125-00

Airflow Rating Points (for AHRI): 1,500 CFM and 1,120 CFM

Number Motors: Direct Drive (DD) Four, Belt Drive (BD) Two

Drive HP Volts HZ Phase FLA

Min. Cir.

Amps

Max. Fuse Size

DD 0.75

115208-230

277208-230

460

6060606060

SingleSingleSingleThreeThree

8.64.32.42.11.1

36.618.310.29.84.9

4520151515

BD 1.5

208-230208-230

460575

60606060

SingleThreeThreeThree

9.3-9.04.8-4.8

2.41.8

20.910.85.44.1

30151515

BD2

208-230208-230

460575

60606060

SingleThreeThreeThree

11.3-10.56.2-6.2

3.12.3

25.414.07.05.2

35201515

Control Voltage: 24 VAC

Filters: Four total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 399 lbs (unit), 420 lbs (shipping weight)

Shipping Dimensions: 48” W x 62” L x 55” H

Motor HP Blower RPM Nominal

Turns Open

External Static Pressure (Inches Water Column)0.0 0.25 0.5 0.75 1.0 1.25 1.5

0.75 (Four DD)

Single PhaseN/AN/A

N/AN/A

1,870 CFM2,160 Watts

1,720 CFM2,070 Watts

1,520 CFM1,900 Watts

1,290 CFM1,715 Watts

1,080 CFM1,505 Watts

700 CFM1,210 Watts

- - - -

0.75 (Four DD)

Three PhaseN/AN/A

N/AN/A

1,870 CFM2,500 Watts

1,720 CFM2,300 Watts

1,540 CFM2,125 Watts

1,350 CFM1,950 Watts

1,240 CFM1,730 Watts

1,030 CFM1,490 Watts

800 CFM1,240 Watts

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

1.5 (BD)1,0001,2301,420

4.520

1,378 0.51,694 0.91,956 1.4

1,175 0.51,550 0.91,850 1.4

900 0.41,335 0.81,680 1.2

635 0.41,125 0.71,475 1.2

- -1,000 0.71,300 1.1

- - 500 0.61,200 1.1

- - - - 930 0.9

2 (BD)1,2201,4701,660

4.520

1,681 0.92,025 1.6 - -

1,530 0.91,925 1.5 - -

1,315 0.71,750 1.42,000 2.0

1,100 0.71,575 1.31,900 1.9

975 0.61,375 1.21,750 1.8

430 0.61,275 1.21,570 1.7

- -1,125 1.11,475 1.7

Airflow Performance

Note: Brake Horse Power (BHP) is for one blower motor package only.

Page 23: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com21

HE2X

INV

Un

it D

imen

sio

ns

TOP

VIE

W a

nd S

ervi

ce A

rea

OARA

FRO

NT

VIE

W

FARA

EAOA

FARA

OA EA

EAFA

RIG

HT

EN

D V

IEW

BE

LT D

RIV

ELE

FT E

ND

VIE

WB

ELT

DR

IVE

RIG

HT

EN

D V

IEW

DIR

EC

T D

RIV

ELE

FT E

ND

VIE

WD

IRE

CT

DR

IVE

8 1/

8"24

"

41 1

/2"

3 1/

2"14"

35 5

/8"

49 1

/8"

35 1

/4"

w/ s

crew

s

38 3

/4"

34 1

/8"

74 7

/8" C

lear

39 1

/4"

43 3

/4"

4 1/

4"

Not

e: A

ll du

ct fl

ange

s ar

e 14

" x 2

4".

E-b

ox p

ower

wire

7/8"

Dia

.5

7/8"

19 3

/8"

6 3/

8"

19 3

/8"

50 5

/8"

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 24: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282422

HE3XINH

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 750-3,300 CFM

AHRI 1060 Certified Core: Three L125-00

Airflow Rating Points (for AHRI): 2,250 CFM and 1,690 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

2

208-230208-230

460575

60606060

SingleThreeThreeThree

11.3-10.56.2-6.2

3.12.3

25.414.07.05.2

35201515

3

208-230208-230

460575

60606060

SingleThreeThreeThree

13.79.2-8.6

4.33.2

30.820.79.77.2

45301515

5208-230

460575

606060

ThreeThreeThree

14.0-13.06.55.0

31.514.611.3

452015

Control Voltage: 24 VAC

Filters: Six total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 675 lbs (unit), 700 lbs (shipping weight)

Shipping Dimensions: 72” W x 84” L x 46” H

Motor HP Blower RPM Nominal Turns Open

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

21,0951,2201,340

420

2,040 1.32,340 1.52,590 1.8

1,760 1.32,110 1.42,370 1.7

1,370 1.21,790 1.32,130 1.6

920 1.11,380 1.21,760 1.4

- - 940 1.21,310 1.3

- - - - 980 1.2

- - - - - -

31,3451,5351,685

4.520

2,420 2.32,850 2.8 - -

2,280 2.22,760 2.7 - -

2,090 2.12,570 2.6 - -

1,760 2.02,380 2.52,660 2.9

1,280 1.92,090 2.42,470 2.7

860 1.91,810 2.22,280 2.6

- -1,330 2.12,000 2.4

51,4951,6751,855

6.53.50

2,850 3.13,280 3.8 - -

2,710 3.03,140 3.7 - -

2.520 2.92,990 3.53,470 4.9

2,280 2.82,800 3.33,330 4.7

2,040 2.72,610 3.13,140 4.5

1,620 2.52,380 2.93,040 4.4

1,140 2.42,090 2.72,760 4.0

Indoor Unit

G5 Performance

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

CFM1,500 2,000 2,500 3,000

80

60

40Effe

ctiv

enes

s (%

)

SensibleWinter Total

Summer Total

Specifications

Airflow Performance

Page 25: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com23

HE3X

INh

Un

it D

imen

sio

ns

Fron

t Vie

wLe

ft Vi

ew

EA

FA

Rig

ht V

iew

RA

Top

View

OA

EA

FA

5 1/8"

40 3/8"

62 1

/4"

62 1

/4"

22 3/8"40 3/8"

18 5/8"

57 1

/4"

64 1

/2" o

vera

ll

62 1/4"

97" Service Area

64 1

/2"

Ser

vice

Are

a

55 1

/8" C

ontro

l Wiri

ng In

let

E-b

ox

58 1

/8" P

ower

Wiri

ng In

let

39"12

"

5 1/2"12"

E-b

ox

26 1/8"

4 1/

4"

OA

12" X

34"

RA

12" X

34"

Not

e: T

here

are

two

12" x

12"

dis

char

ges.

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 26: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282424

HE3XINV

Motor HP Blower RPM Nominal Turns Open

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

21,0951,2201,340

420

1,900 1.32,200 1.52,300 1.7

1,600 1.21,960 1.42,160 1.6

1,250 1.21,610 1.31,950 1.5

850 1.11,240 1.31,580 1.4

- - 860 1.21,150 1.3

- - - - 800 1.2

- - - - - -

31,3451,5351,685

4.520

2,400 2.22,720 2.7 - -

2,250 2.22,450 2.52,870 3.0

1,970 2.12,250 2.42,740 2.9

1,570 2.01,950 2.32,540 2.8

1,170 1.91,650 2.22,340 2.7

900 1.81,200 2.02,090 2.5

- - 875 1.91,800 2.4

51,4951,6751,855

6.53.50

2,850 2.73,230 3.73.520 4.5

2,610 2.63,090 3.53,370 4.3

2.380 2.52,850 3.33,230 4.1

2,090 2.42,610 3.13,090 3.9

1,710 2.22,380 2.92,850 3.6

1,330 2.12,090 2.72,610 3.4

950 2.01,810 2.52,380 3.2

Indoor Unit

G5 Performance

Specifications

Airflow Performance

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

CFM1,500 2,000 2,500 3,000

80

60

40Effe

ctiv

enes

s (%

)

SensibleWinter Total

Summer Total

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 750-3,300 CFM

AHRI 1060 Certified Core: Three L125-00

Airflow Rating Points (for AHRI): 2,250 CFM and 1,690 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

2

208-230208-230

460575

60606060

SingleThreeThreeThree

11.3-10.56.2-6.2

3.12.3

25.414.07.05.2

35201515

3

208-230208-230

460575

60606060

SingleThreeThreeThree

13.79.2-8.6

4.33.2

30.820.79.77.2

45301515

5208-230

460575

606060

ThreeThreeThree

14.0-13.06.55.0

31.514.611.3

452015

Control Voltage: 24 VAC

Filters: Six total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 640 lbs (unit), 675 lbs (shipping weight)

Shipping Dimensions: 45” W x 70” L x 70” H

Page 27: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com25

HE3X

INV

Un

it D

imen

sio

ns

Fron

t Vie

w

35 1

/4"

62"

3 7/8"

Left

View

EA

61 3

/4"

OA

62"

Rig

ht V

iew

FA

37 1/2"

55 7

/8"

RA

39 3/8" overall

Top

View

61 3

/4" U

nit

95 7

/8" S

ervi

ce A

rea

OA

EA

RA

FA

43 1/4"Service Area

58 1

/8"

61 3

/4"

7/8"

Dia

.W

iring

Ent

ries

E-b

ox

47"

1"1"

47"RA

14" X

28"

FA 1

2" x

12"

OA

14" X

28"

EA

12" x

12"

8 3/4"12"

38 7

/8"

12"

8 3/4"12"

38 7

/8"

12"

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 28: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282426

HE4XINH

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 1,000-4,400 CFM

AHRI 1060 Certified Core: Four L125-00

Airflow Rating Points (for AHRI): 3,000 CFM and 2,250 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

2

208-230208-230

460575

60606060

SingleThreeThreeThree

11.3-10.56.2-6.2

3.52.3

25.414.07.95.2

35201515

3

208-230208-230

460575

60606060

SinlgeThreeThreeThree

13.79.2-8.6

4.33.2

30.820.79.77.2

45301515

5208-230

460575

606060

ThreeThreeThree

14.0-13.06.55.0

31.514.611.3

452015

Control Voltage: 24 VAC

Filters: Eight total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 846 lbs (unit), 900 lbs (shipping weight)

Shipping Dimensions: 84” W x 92” L x 46” H

Motor HP Blower RPM Nominal Turns Open

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

21,0101,2101,370

4.520

2,489 0.92,995 1.6 - -

2,200 0.92,290 1.5 - -

1,715 0.82,430 1.4 - -

1,100 0.72,005 1.32,600 2.0

- -1,540 1.22,215 1.9

- - - -1,800 1.7

- - - -1,100 1.5

31,3451,5351,685

4.520

3,295 2.13,832 2.9 - -

3,145 2.13,682 2.9 - -

2,840 2.03,480 2.8 - -

2,509 1.93,170 2.6 - -

2,116 1.82,839 2.43,409 3.0

1,747 1.62,449 2.33,003 2.8

1,135 1.51,878 2.02,465 2.4

51,4951,6751,855

630

3,718 2.74,223 3.8 - -

3,568 2.64,083 3.7 - -

3,345 2.63,943 3.6 - -

3,030 2.43,659 3.44,287 4.9

2,686 2.23,364 3.24,011 4.6

2,301 2.12,994 2.93,760 4.3

1,722 1.92,490 2.73,434 4.0

Indoor Unit

G5 PerformanceCFM

1,000 2,000 3,000 4,000

80

60

40

SensibleWinter Total

Summer Total

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

Effe

ctiv

enes

s (%

)

Specifications

Airflow Performance

Page 29: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com27

HE4X

INh

Un

it D

imen

sio

ns

RA

12" X

40"

25 1/2"

5 1/2"

77 7

/8" P

ower

Wiri

ng In

let

22 3/8"

5 1/8"

Left

View

Fron

t Vie

wR

ight

Vie

w

74 7

/8" C

ontro

l Wiri

ng In

let

82"

40 3/8"

18 5/8"

FAEA

E-b

ox

E-b

ox

116 3/4" Service Area

40 3/8"

OA

12" X

40"

EA

OA

FAR

A

57 1

/4"

82"

4 1/

4"

64 1

/2"

Ser

vice

Are

aTo

p Vi

ew

64 1

/2" o

vera

ll

82"

39"

12" x

32"

typ

OA

RA

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 30: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282428

HE4XINV

Motor HP Blower RPM Nominal Turns Open

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

21,0101,2101,370

4.520

2,300 0.92,800 1.53,068 2.2

1,810 0.82,350 1.42,754 2.0

1,300 0.71,950 1.32,430 1.9

- -1,500 1.32,082 1.8

- -1,050 1.21,725 1.7

- - - -1,342 1.6

- - - - - -

31,3451,5351,685

4.520

3,042 2.03,452 2.7 - -

2,705 1.93,226 2.6 - -

2,341 1.82,955 2.5 - -

1,983 1.72,696 2.33,148 2.9

1,611 1.62,422 2.22,884 2.8

1,211 1.52,093 2.02,595 2.6

- -1,722 1.92,269 2.4

51,4951,6751,855

630

3,348 2.73,896 3.9 - -

3,114 2.63,688 3.7 - -

2,820 2.43,466 3.64,229 4.9

2,549 2.33,232 3.43,979 4.6

2,268 2.22,972 3.23,700 4.3

1,917 2.12,694 3.03,430 4.0

1,523 1.92,392 2.83,178 3.8

Indoor Unit

G5 Performance

Specifications

Airflow Performance

CFM1,000 2,000 3,000 4,000

80

60

40

SensibleWinter Total

Summer Total

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

Effe

ctiv

enes

s (%

)

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 1,000-4,400 CFM

AHRI 1060 Certified Core: Four L125-00

Airflow Rating Points (for AHRI): 3,000 CFM and 2,250 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

2

208-230208-230

460575

60606060

SingleThreeThreeThree

11.3-10.56.2-6.2

3.52.3

25.414.07.95.2

35201515

3

208-230208-230

460575

60606060

SinlgeThreeThreeThree

13.79.2-8.6

4.33.2

30.820.79.77.2

45301515

5208-230

460575

606060

ThreeThreeThree

14.0-13.06.55.0

31.514.611.3

452015

Control Voltage: 24 VAC

Filters: Eight total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 815 lbs (unit), 875 lbs (shipping weight)

Shipping Dimensions: 45” W x 90” L x 70” H

Page 31: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com29

HE4X

INV

Un

it D

imen

sio

ns

OA

FA EA

RA

EA

OA

FA

RA

OA

FAE

A

RA

81 3

/8"

3 7/8"

62"

35 1

/4"

62 1/4"

81 3

/8"

115

1/2"

Ser

vice

Are

a39 3/8"

with flanges

81 1

/2" U

nit

75 1

/2"

37 1/2"Le

ft Vi

ewFr

ont V

iew

Rig

ht V

iew

Top

View

7/8"

Dia

.W

iring

Ent

ries

E-b

ox

1"38 7

/8"

8 1/2"47"

1"38

3/4

"

8 1/2"

12" X

32"

14" X

34"

12" X

32"

14" X

34"

47"

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 32: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282430

HE6XIN

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 1,500-6,500 CFM

AHRI 1060 Certified Core: Six L125-00

Airflow Rating Points (for AHRI): 4,500 CFM and 3,375 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

5208-230

460575

606060

ThreeThreeThree

14.2-13.06.55.0

32.614.911.3

452015

7.5208-230

460575

606060

ThreeThreeThree

20.9-19.29.67.6

47.021.617.1

703025

Control Voltage: 24 VAC

Filters: Twelve total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 2,340 lbs (unit), 2,640 lbs (shipping weight)

Shipping Dimensions: 85” W x 114” L x 85” H

Motor HP Blower RPM Nominal Turns Open

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

51,4601,6101,725

4.520

5,005 3.25,550 4.2 - -

4,800 3.25,375 4.2 - -

4,650 3.15,250 4.1 - -

4,475 3.05,100 4.15,525 5.0

4,200 2.94,900 4.05,475 5.0

4,000 2.84,650 3.95,200 4.9

3,750 2.84,500 3.85,050 4.8

7.51,5601,7401,865

4.520

5,275 3.75,950 5.06,500 6.5

5,200 3.65,825 5.06,350 6.5

4,900 3.55,625 4.96,225 6.4

4,775 3.55,490 4.96,125 6.4

4,550 3.45,325 4.85,910 6.3

4,350 3.35,125 4.75,825 6.2

4,125 3.34,950 4.75,625 6.1

Indoor Unit

G5 PerformanceCFM

3,000 4,000 5,000 6,000

80

60

40

SensibleWinter Total

Summer Total

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

Effe

ctiv

enes

s (%

)

Specifications

Airflow Performance

Page 33: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com31

HE6X

INU

nit

Dim

en

sio

ns

62"

112

3/4"

Uni

t Roo

f

108

1/2"

Bas

e

108

1/2"

Bas

e

EA

18"

39 1

/2" M

in.

Cle

aran

ce

85 1

/2" U

nit R

oof

148

1/4"

Ser

vice

Are

a

34"Service Area

FRO

NT

VIE

W

LEFT

VIE

WB

AC

K V

IEW

RIG

HT

VIE

W

4"9"

24"77"

9 1/

2"49

"

24"

typ

22"36"

TOP

VIE

W

OARA

FA

Pow

er a

ndC

ontro

lW

iring

Ent

ries

7/8"

Dia

.

Pow

er a

nd C

ontro

l Wiri

ngE

ntrie

s

EA

Cor

eA

cces

s

FA B

LOW

ER

Out

let i

s 18

" x 2

4".

24" x

36"

Duc

t Fla

nge

is a

lso

supp

lied.

Fiel

d in

stal

l onl

y in

loca

tion

show

n.

62"

IND

OO

R U

NIT

S: E

A B

LOW

ER

Out

let i

s 18

" x 2

4".

24" x

36"

Duc

t Fla

nge

is a

lso

supp

lied.

Fie

ld in

stal

l onl

y in

loca

tion

show

n.

Fron

t Vie

ws

at 0

.5X

:B

LOW

ER

RO

TATI

ON

55"

78 1/4" Overall

151 1/2" Service Area

36"

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 34: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282432

HE8XIN

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 2,000-8,000 CFM

AHRI 1060 Certified Core: Eight L125-00

Airflow Rating Points (for AHRI): 6,000 CFM and 4,500 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

5208-230

460575

606060

ThreeThreeThree

14.2-13.06.55.0

32.614.911.3

452015

7.5208-230

460575

606060

ThreeThreeThree

20.9-19.29.67.6

47.021.617.1

703025

10208-230

460575

606060

ThreeThreeThree

29.0-26.813.410.0

65.330.222.5

904535

Control Voltage: 24 VAC

Filters: Sixteen total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 2,525 lbs (unit), 2,825 lbs (shipping weight)

Shipping Dimensions: 85” W x 114” L x 85” H

Motor HP Blower RPM Nominal Turns Open

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

51,4601,6101,725

4.52

0.5

5,575 3.26,200 4.36,550 5.0

5,425 3.26,010 4.36,380 5.0

5,200 3.25,875 4.26,210 5.0

5,000 3.25,700 4.26,100 5.0

4,775 3.15,500 4.25,880 4.9

4,550 3.05,325 4.15,730 4.8

4,270 2.95,125 4.15,510 4.8

7.51,5601,7401,865

4.520

6,000 3.96,700 5.3 - -

5,850 3.96,575 5.3 - -

5,650 3.86,400 5.3 - -

5,475 3.86,300 5.36,800 7.5

5,275 3.86,125 5.36,675 7.5

5,100 3.75,950 5.26,500 7.5

4,875 3.75,750 5.26,375 7.4

101,8102,0202,105

4.521

7,000 6.17,850 8.5 - -

6,875 6.17,745 8.5 - -

6,750 6.17,625 8.57,950 9.6

6,600 6.07,450 8.47,800 9.6

6,425 6.07,350 8.47,725 9.6

6,275 6.07,200 8.37,600 9.5

6,100 5.97,050 8.37,450 9.5

CFM2,000 4,000 6,000 8,000

80

60

40

SensibleWinter Total

Summer Total

Indoor Unit

G5 Performance

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

Effe

ctiv

enes

s (%

)

Specifications

Airflow Performance

Page 35: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com33

HE8X

INU

nit

Dim

en

sio

ns

62"

112

3/4"

Uni

t Roo

f

108

1/2"

Bas

e

108

1/2"

Bas

e

EA

18"

39 1

/2" M

in.

Cle

aran

ce

85 1

/2" U

nit R

oof

148

1/4"

Ser

vice

Are

a

34"Service Area

FRO

NT

VIE

W

LEFT

VIE

WB

AC

K V

IEW

RIG

HT

VIE

W

4"9"

24"77"

9 1/

2"49

"

24"

typ

22"36"

TOP

VIE

W

OARA

FA

Pow

er a

ndC

ontro

lW

iring

Ent

ries

7/8"

Dia

.

Pow

er a

nd C

ontro

l Wiri

ngE

ntrie

s

EA

Cor

eA

cces

s

FA B

LOW

ER

Out

let i

s 18

" x 2

4".

24" x

36"

Duc

t Fla

nge

is a

lso

supp

lied.

Fiel

d in

stal

l onl

y in

loca

tion

show

n.

62"

IND

OO

R U

NIT

S: E

A B

LOW

ER

Out

let i

s 18

" x 2

4".

24" x

36"

Duc

t Fla

nge

is a

lso

supp

lied.

Fie

ld in

stal

l onl

y in

loca

tion

show

n.

Fron

t Vie

ws

at 0

.5X

:B

LOW

ER

RO

TATI

ON

55"

78 1/4" Overall

151 1/2" Service Area

36"

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 36: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282434

Commercial

OutDOOR Products

Many airflow orientation options.•

Weatherized cabinets with hoods for • outdoor applications.

Wide range of airflow and static capacities.•

Easy installation and service.•

AHRI certified performance data for • efficiency and cross leakage.

UL tested flammability and • smoke generation that meets NFPA 90A and 90B test standards for commercial applications.

Ten year core warranty.•

RenewAire means Trouble-Free ERV.

EA: Exhaust Air to outdoorsOA: Outdoor Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside

Contact RenewAire for other application schematics.

Page 37: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com35

Part I - General

A. Product Specification

1.Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology. B. Quality Assurance

1.The energy recovery cores used in these products shall be third party Certified by AHRI under its Standard 1060 for Energy Recovery Ventilators. AHRI published certifications shall confirm manufacture’s published performance for airflow, static pressure, temperature and total effectiveness, purge air (OACF) and exhaust air leakage (EATR). Products that are not currently AHRI Certified will not be accepted.

2. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 25 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system. The method of test shall be UL Standard 723.

3. Unit shall be Listed under UL 1812 Standard for Ducted Air to Air Heat Exchangers (Note that a few low volume product or product configurations are not UL Listed). Units intended for “Outdoor Use” shall be listed using the specific UL requirements for rain penetration, corrosion protection and seal durability and shall be so labeled.

4. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase.

Part II – Performance

A. Energy TransferThe ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air.

B. Passive Frost ControlThe ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10°F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed.

C. Continuous VentilationUnit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions.

D. Positive Airstream SeparationWater vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by “porous plate” mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages, and airstreams shall not mix.

E. Laminar FlowAirflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material.

Part III – Product

A. Construction

1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts.

2. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate.

3. The unit case shall be constructed of G90 galvanized, 20-gauge steel, with lapped corners and zinc plated screw fasteners. The unit roof shall be one piece or have watertight standing seam joints and shall overlap wall panels and doors in order to positively shed water.

4. Access doors shall provide easy access to blowers, ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets rated for outdoor exposure.

5. Weatherhoods shall be screened to exclude birds and animals. Inlet weatherhoods shall be sized to maintain inlet velocities below 500 fpm, and equipped with rain excluder baffles.

6. Case walls and doors shall be insulated with 1 inch, 4 pound density, foil/scrim faced, high-density fiberglass board insulation, providing a cleanable surface and eliminating the possibility of exposing the fresh air to glass fibers.

7. The ERV cores shall be protected by a MERV-8 rated, 2” nominal, pleated, disposable filter in both airstreams.

8. Unit shall have single-point power connection and a single-point 24 VAC contactor control connection (Except Inverter Ready units that have terminal connections for an independent inverter for each airstream).

9. Blower motors shall be EPACT compliant for energy efficiency and be thermally protected or supplied with external starters.

10. Blowers shall be quiet running, forward curve type and be either direct drive or belt drive. HE6X and HE8X units use backward incline, belt drive blower packages. Belt drive motors shall be provided with adjustable pulleys and motor mounts allowing for proper belt tensioning. B. Options (Select options based on application requirements)

1. Provide unit and duct connection orientation per project schedule.

2. Provide double wall construction with 24-gauge galvanized steel liner.

3. Units are available single or three phase at a full range of operating voltages. See project schedule.

4. Provide motor horsepower as specified in project schedule.

5. Provide “inverter-ready” units which include shielded power wiring and terminal connections for inverters (inverters provided and installed by others).

6. Provide factory installed fused disconnects.

7. Provide factory installed non-fused disconnects.

8. Provide factory installed transformer/relay package to supply a 24VAC power source.

9. Provide factory installed filter monitors for each airstream.

10. Provide 14 inch high, non-pitched roof curbs as available from the factory. Pitched curbs, vibration curbs, seismic curbs and other custom curbs are available directly from curb manufacturer.

11. RTC (RoofTop Connect) units shall have return air and fresh air ducts configured to permit direct tie-in to rooftop air handlers using factory offered transition piece. (See separate specification for factory transition availability.)

12. Provide high wind tie-down kit.

Packaged Rooftop Energy Recovery Ventilators: EV450RT, HE1XRT, HE2XRT, HE3XRT, HE4XRT, HE6XRT & HE8XRT

Page 38: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282436

EV450RT

Dimensions

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 240-550 CFM

AHRI 1060 Certified Core: One L85

Airflow Rating Points (for AHRI): 450 CFM and 338 CFM

Motors: One, 0.6 hp (Single Phase) One, 0.5 hp (Three Phase)

V HZ Phase FLA

115 60 Single 7.0

208-230 60 Single 3.5

277 60 Single 2.4

208-230 60 Three 1.7-1.5

460 60 Three 0.8

Control Voltage: 24 VAC

Filters: Two total, MERV 8, 2” pleated, 14” x 20” nominal size

Weight: 185 lbs (unit), 235 lbs (shipping weight)

Shipping Dimensions: 48” W x 90” L x 25” H (on pallet)

Airflow CFM

ESP in H20

Watts1P 3P

Temp EFF%

Total EFF%Winter/Summer*

240 1.00 425 243 80 75/66

338 0.85 474 313 77 71/61

380 0.75 496 345 75 69/59

450 0.50 534 412 73 66/56

500 0.25 563 461 71 64/54

550 0.00 593 516 70 62/52

600 -0.25 623 572 68 60/50

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

Outdoor Unit Specifications

G5 Performance

74 7/8

19 1/4OA

EA

OAEA

RAFA

RIGHT VIEW

47 7/8

1

4 3/4

4 3/81

33 7/8 12 3/8

PWR ANDCONTROL WIRING

DRILL HEREOR THRU BOTTOM

2 7/83 1/8

LEFT VIEW 3 1/8

EBOX

RAFRONTVIEWFA

37 1/2

TOP VIEW WITH DOOR OFF

FILTERS

2 5/813 1/82 3/4

11 3/4

8 3/45 1/2

10 1/4

4 1/2

Page 39: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com37

The RTH/RTC Adapter allows horizontal connection of both the Fresh Air and the Return Air ducts. It is also possible to connect the adapter directly to the return plenum of most Rooftop Units (openings must be cut into RTU). Duct openings to be field cut into adapter. Opening location and size is flexible.

For horizontal connection of either the Fresh Air duct or the Return Air duct, stack the optional RTF/RTR Adapter on the Standard Roof Curb. Duct openings to be field cut into adapter. Opening location and size is flexible.

Standard Roof Curb Shown (available option). Curbs for sloped roofs or metal roofing are available on a custom basis from RenewAire or from local curb fabricators.

EV450RTApplication options

EA: Exhaust Air to outdoorsOA: Outdoor Air intakeRA: Room Air to be exhaustedFA: Fresh Air to inside

Page 40: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282438

HE1XRT

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 250-870 CFM

AHRI 1060 Certified Core: One L125-00

Airflow Rating Points (for AHRI): 750 CFM and 560 CFM

Number Motors: Two

V HZ Phase FLA Min. Cir. Amps

Max. Fuse Size

115 60 Single 8.6 19.4 25

208-230 60 Single 4.3 9.7 15

277 60 Single 2.4 5.4 15

208-230 60 Three 2.1 5.2 15

460 60 Three 1.1 2.6 15

Control Voltage: 24 VAC

Filters: Two total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 250 lbs (unit), 330 lbs (shipping weight)

Shipping Dimensions: 31” W x 76” L x 45” H

Options: Controls (see pages 64 & 65) Roof curb Alternate duct connections

Outdoor Unit Specifications

OA

RAFA

EA

RTV

OA

RA

FA

EA

RTF

Base Type/Airflow Orientations

OA

RA

EA

FA

RTR

OA

RA

EA

FA

RTH

Motor HPPhase

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

0.75 (Two DD)Single Phase

950 CFM1,630 Watts

880 CFM1,550 Watts

820 CFM1,475 Watts

775 CFM1,430 Watts

730 CFM1,385 Watts

650 CFM 1,300 Watts

540 CFM 1,200 Watts

0.75 (Two DD)Three Phase

950 CFM1,200 Watts

880 CFM1,100 Watts

820 CFM1,020 Watts

760 CFM 980 Watts

660 CFM 890 Watts

560 CFM 800 Watts

450 CFM 700 Watts

G5 PerformanceCFM

250 500 750 1,000

80

60

40

Effe

ctiv

enes

s (%

)

SensibleWinter Total

Summer Total

*At AHRI 1060 standard conditions(See certified data on page 67 for core components.)

Airflow Performance

Page 41: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com39

CURB

1X

HE1X

RT

Un

it D

imen

sio

ns

ON

LYR

TH, R

TFR

AOA

FAR

TV, R

TFO

NLY

RTV

, RTR

ON

LY

RA

RTH

, RTR

EA

FAO

NLY

RA

(RTH

,RTF

)12

" x 1

2"

OA

FA (R

TH,R

TR)

12" x

12"

Con

trol W

iring

Inle

t7/

8" D

ia.

Pow

er W

iring

Inle

t7/

8" D

ia.

Ser

vice

Are

a

RA

(RTV

,RTR

)12

" x 1

2"

FA (R

TV,R

TF)

12" x

12"

RIG

HT

VIE

WFR

ON

TV

IEW

LEFT

VIE

W

TOP

VIE

W

10 3/8"17 3/8" Control

19 1/4" Power

22 1/2"56 1/8"

4"14

3/4

"29

1/2

"44 1

/4"55

"63 7

/8"

4 7/8"

40 1/4"

3"4

3/8" 4 7/8"

9"

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 42: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282440

HE1XRTC

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 500-1,000 CFM

AHRI 1060 Certified Core: One L125-00

Airflow Rating Points (for AHRI): 750 CFM and 560 CFM

Number Motors: Two

V HZ Phase FLA Min. Cir. Amps

Max. Fuse Size

115 60 Single 8.6 19.4 25

208-230 60 Single 4.3 9.7 15

277 60 Single 2.4 5.4 15

208-230 60 Three 2.1 5.2 15

460 60 Three 1.1 2.6 15

Control Voltage: 24 VAC

Filters: Two total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 300 lbs (unit), 375 lbs (shipping weight)

Shipping Dimensions: 40” W x 87” L x 45” H

Damper Position

Total Watts Static Pressure in Adjacent Air Handler (Inches Water Column)

-0.5 -0.25 0.0 +0.25 +0.51 Phase 3 Phase

EA FA EA FA EA FA EA FA EA FA

100% Open 1,295 1,155 855 1,035 900 985 950 940 985 885 1,045 835

65% Open 1,285 1,140 785 980 820 945 855 900 890 855 935 810

55% Open 1,275 1,130 775 965 805 920 840 875 865 835 900 790

45% Open 1,265 1,120 750 920 775 875 805 935 830 790 860 750

35% Open 1,265 1,110 695 860 730 820 760 775 790 740 820 700

25% Open 1,265 1,100 625 780 660 750 685 715 715 680 750 650

15% Open 1,260 1,085 575 585 615 630 650 665 685 705 730 745

CFM300 500 700 900

80

60

40

Effe

ctiv

enes

s (%

)

SensibleWinter Total

Summer Total

Outdoor Unit

G5 Performance

Specifications

*At AHRI 1060 standard conditions(See certified data on page 67 for core components).

Airflow Performance

Page 43: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com41

HE1X

RTC

Un

it D

imen

sio

ns

RA

EA

Ser

vice

Are

a

RIG

HT

VIE

W

FRO

NT

VIE

WS

how

n w

ith L

evel

ing

Legs

(shi

pped

loos

e)LE

FT V

IEW

TOP

VIE

W

22 1/2"

56 1/8"

21 1

/8"

72"

40 1/4"

FA RA

FA

OA

EA

RA

FA

OA

OA

9"

14 1

/2" t

o 17

1/2

"he

ight

adj

ustm

ent

19 7

/8"

Lifti

ng L

ugs

46 3

/8"

Lifti

ng L

ugs

Pow

er W

ire In

7/8"

Dia

.

Con

trol W

ire In

7/8"

Dia

.

51"

Acc

ess

to b

low

ers

Acc

ess

to

Ele

ctric

al

Com

pone

nts,

OA

filte

r

6 5/

8"

11"

3 1/

2"

11"

9"

16"

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 44: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282442

HE2XRTOutdoor Unit

G5 Performance

Specifications

CFM500 1,000 1,500 2,000

80

60

40

SensibleWinter Total

Summer Total

Effe

ctiv

enes

s (%

)

*At AHRI 1060 standard conditions(See certified data on page 67 for core components).

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 500-2,000 CFM

AHRI 1060 Certified Core: Two L125-00

Airflow Rating Points (for AHRI): 1,500 CFM and 1,120 CFM

Number Motors: Direct Drive (DD) Four, Belt Drive (BD) Two

Drive HP Volts HZ Phase FLA

Min. Cir.

Amps

Max. Fuse Size

DD 0.75

115208-230

277208-230

460

6060606060

SingleSingleSingleThreeThree

8.64.32.42.11.1

36.618.310.29.84.9

4520151515

BD 1.5

208-230208-230

460575

60606060

SingleThreeThreeThree

9.3-9.04.8-4.8

2.41.8

20.910.85.44.1

30151515

BD2

208-230208-230

460575

60606060

SingleThreeThreeThree

11.3-10.56.2-6.2

3.12.3

25.414.07.05.2

35201515

Control Voltage: 24 VAC

Filters: Four total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 488 lbs (unit), 525 lbs (shipping weight)

Shipping Dimensions: 51” W x 76” L x 45” H

OA

RAFA

EA

RTV

OA

RA

FA

EA

RTF

Base Type/Airflow Orientations

OA

RA

EA

FA

RTR

OA

RA

EA

FA

RTH

Motor HP Blower RPM Nominal

Turns Open

External Static Pressure (Inches Water Column)0.0 0.25 0.5 0.75 1.0 1.25 1.5

0.75 (Four DD)

Single PhaseN/AN/A

N/AN/A

1,770 CFM2,220 Watts

1,680 CFM2,145 Watts

1,555 CFM2,015 Watts

1,375 CFM1,825 Watts

1,110 CFM1,560 Watts

760 CFM1,195 Watts

- - - -

0.75 (Four DD)

Three PhaseN/AN/A

N/AN/A

1,760 CFM2,300 Watts

1,670 CFM2,200 Watts

1,550 CFM2,050 Watts

1,375 CFM1,825 Watts

1,120 CFM1,530 Watts

850 CFM1,375 Watts

500 CFM 950 Watts

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

1.5 (BD)1,0001,2301,420

4.520

1,378 0.51,694 0.91,956 1.4

1,175 0.51,550 0.91,850 1.4

900 0.41,335 0.81,680 1.2

635 0.41,125 0.71,475 1.2

- -1,000 0.71,300 1.1

- - 500 0.61,200 1.1

- - - - 930 0.9

2 (BD)1,2201,4701,660

4.520

1,681 0.92,025 1.6 - -

1,530 0.91,925 1.5 - -

1,315 0.71,750 1.42,000 2.0

1,100 0.71,575 1.31,900 1.9

975 0.61,375 1.21,750 1.8

430 0.61,275 1.21,570 1.7

- -1,125 1.11,475 1.7

Airflow Performance

Note: Brake Horse Power (BHP) is for one blower motor package only.

Page 45: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com43

HE2X

RT

Un

it D

imen

sio

ns

20 1/8"Curb

Center

34 7/8"control

37 3/8"power

42 1/4"

76 1/8"

10 5

/8"

25 1

/2"

Cur

bC

ente

r

51 1

/8"

72 3

/8"

15 3

/4"

15 3

/4"

3 3/

4"

4 5/8"

7 1/

4"

40 1

/4"

39 3/8"

3"Top ofCurb

43 1

/4"

FRO

NT

VIE

WLE

FT V

IEW

RIG

HT

VIE

W

TOP

VIE

W

Ser

vice

Are

a

RA

(RTV

RTR

)10

" X 2

4"FA

(RTV

, RTF

)10

" X 2

4"

FA (R

TH, R

TR)

14" X

24"

RA

(RTH

, RTF

)14

" X 2

4"O

A

EA

OA

EA

RA

FA

RTV

, RTF

O

NLY

RTV

, RTR

O

NLY

FAR

TH, R

TR

ON

LYR

TH, R

TFO

NLY

RA

4" Wiring Inlet Pow

er W

iring

Inle

t7/

8" D

ia.

Con

trol W

iring

Inle

t7/

8" D

ia.

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

CURB

2X

Page 46: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282444

HE2XRTC

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 1,000-1,700 CFM

AHRI 1060 Certified Core: Two L125-00

Airflow Rating Points (for AHRI): 1,500 CFM and 1,120 CFM

Number Motors: Two, Belt Drive

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

BD2 208-230 60 Single 11.3-10.5 25.4 35

BD2

208-230460575

606060

ThreeThreeThree

6.2-6.23.12.3

14.07.05.2

201515

Control Voltage: 24 VAC

Filters: Four total, MERV 8, 2” pleated, two 20” x 20” nominal size, and two 14” x 20” nominal size

Weight: 538 lbs (unit), 575 lbs (shipping weight)

Shipping Dimensions: 51” W x 76” L x 45” H

Blower RPM Nominal Turns Open

Static Pressure in Adjacent Air Handler (Inches Water Column)-0.5 -0.25 0.0 +0.25 +0.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

Exhaust Air

1,420 0 1,700 1.8 1,850 1.9 - - - - - -

1,360 1 1,540 1.7 1,720 1.8 1,860 1.9 1,920 2.0 1,980 2.0

1,300 2 1,375 1.5 1,600 1.7 1,740 1.8 1,800 1.8 1,860 1.9

1,240 3 1,240 1.4 1,440 1.6 1,625 1.7 1,690 1.7 1,740 1.7

1,180 4 1,080 1.3 1,300 1.4 1,500 1.5 1,575 1.6 1,640 1.6

Fresh Air

1,675 0 - - - - 1,630 2.0 1,575 2.0 1,465 1.9

1,595 1 1,720 2.0 1,620 2.0 1,530 1.9 1,440 1.8 1,355 1.7

1,515 2 1,630 1.9 1,520 1.8 1,430 1.8 1,355 1.7 1,230 1.6

1,435 3 1,530 1.8 1,430 1.7 1,320 1.7 1,250 1.6 1,135 1.5

1,355 4 1,415 1.6 1,310 1.6 1,225 1.5 1,150 1.5 1,035 1.4

Outdoor Unit

G5 Performance

Specifications

Airflow Performance

CFM500 1,000 1,500 2,000

80

60

40

SensibleWinter Total

Summer Total

Effe

ctiv

enes

s (%

)

*At AHRI 1060 standard conditions(See certified data on page 67 for core components).

Page 47: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com45

HE2X

RTC

Un

it D

imen

sio

ns

RIG

HT

VIE

W

57 3

/4"

RAFA

EA

FA RA

EA

OA

EA

FA RA

42 1

/4"

4 1/

2"29

"

1 7/8"

7 3/

4" to

10

1/2"

he

ight

adj

ustm

ent

7 1/8"

21 3/4"11 1/8" typ

39 1/4"

39 1/4"

32"37 1/4"39 1/4"

39 1/4"

57 3

/4"

75 1

/8"

42 3

/8"

40 1

/8"

60 3

/8"

75 1

/8"

37 1/4"LiftingLugs

101" Service Area76

"52 3

/4"

Lifti

ng L

ugs

each

cor

ner

OA

FA RA

EA

FRO

NT

VIE

Wsh

own

with

leve

ling

legs

(shi

pped

loos

e)

LEFT

VIE

WB

AC

K V

IEW

TOP

VIE

W a

nd

serv

ice

area

Con

trol W

iring

In7/

8" D

ia.

Pow

er W

iring

In7/

8" D

ia.

Filte

r Acc

ess

OA

59"

C-C

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 48: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282446

HE3XRT

Motor HP Blower RPM Nominal Turns Open

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

21,0951,2201,340

420

2,040 1.32,340 1.52,590 1.8

1,760 1.32,110 1.42,370 1.7

1,370 1.21,790 1.32,130 1.6

920 1.11,380 1.21,760 1.4

- - 940 1.21,310 1.3

- - - - 980 1.2

- - - - - -

31,3451,5351,685

4.520

2,420 2.32,850 2.8 - -

2,280 2.22,760 2.7 - -

2,090 2.12,570 2.6 - -

1,760 2.02,380 2.52,660 2.9

1,280 1.92,090 2.42,470 2.7

860 1.91,810 2.22,280 2.6

- -1,330 2.12,000 2.4

51,4951,6751,855

6.53.50

2,850 3.13,280 3.8 - -

2,710 3.03,140 3.7 - -

2.520 2.92,990 3.53,470 4.9

2,280 2.82,800 3.33,330 4.7

2,040 2.72,610 3.13,140 4.5

1,620 2.52,380 2.93,040 4.4

1,140 2.42,090 2.72,760 4.0

Outdoor Unit

G5 Performance

Specifications

Airflow Performance

CFM1,500 2,000 2,500 3,000

80

60

40

SensibleWinter Total

Summer Total

Effe

ctiv

enes

s (%

)

*At AHRI 1060 standard conditions(See certified data on page 67 for core components).

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 750-3,000 CFM

AHRI 1060 Certified Core: Three L125-00

Airflow Rating Points (for AHRI): 2,250 CFM and 1,690 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

2

208-230208-230

460575

60606060

SingleThreeThreeThree

11.3-10.56.2-6.2

3.12.3

25.414.07.05.2

35201515

3

208-230208-230

460575

60606060

SingleThreeThreeThree

13.79.2-8.6

4.33.2

30.820.79.77.2

45301515

5208-230

460575

606060

ThreeThreeThree

14.0-13.06.55.0

31.514.611.3

452015

Control Voltage: 24 VAC

Filters: Six total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 726 lbs (unit), 755 lbs (shipping weight)

Shipping Dimensions: 72” W x 84” L x 49” H

OA

RAFA

EA

RTV

OA

RA

FA

EA

RTF

Base Type/Airflow Orientations

OA

RA

EA

FA

RTR

OA

RA

EA

FA

RTH

Page 49: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com47

CURB

3X

HE3X

RT

Un

it D

imen

sio

ns

Left

View

FA

Fron

t Vie

w

Rig

ht V

iew

Top

View

RA

OA

RA

FA

FA

97"

Ser

vice

Are

a

RA

(RTV

, RTR

Onl

y)11

" x 3

4"

8 1/8"14 3/4"

RA

17 1

/2"

18 3

/8"

28 3

/4"

Cur

b C

ente

r

30 1

/8"

Cur

b C

ente

r

EA

FA(R

TV, R

TF O

nly)

12" x

12"

64 1

/2" S

ervi

ce A

rea

40 3

/8"

4 1/

8"

5 1/8"

34" X

12"

RA

Inle

t(R

TH, R

TF)

62 1

/4"

Ove

rall

4"Top of Curb

OA

Inle

t

60 1

/4"

89 3

/4" O

vera

ll

9"

57"

2"

21 3

/4"

12" X

12"

FA O

utle

t(R

TH, R

TR)

EA

Out

let

40 3

/8"

5 1/2"

58 1

/8" P

ower

Wire

Inle

t55

1/8

" Con

trol W

ire In

let

12"

38 3

/4"

18 5/8"

Wiri

ng In

7/8"

Dia

.

E-b

ox

EA

55 1

/4" l

ift lu

gs60

1/4

" lift

lugs

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 50: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282448

HE3XRTC

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 1,700-2,500 CFM

AHRI 1060 Certified Core: Three L125-00

Airflow Rating Points (for AHRI): 2,250 CFM and 1,690 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

3 208-230 60 Single 13.7-13.7 30.8 45

3208-230

460575

606060

ThreeThreeThree

9.2-8.64.43.2

20.79.97.2

301515

Control Voltage: 24 VAC

Filters: Five total, MERV 8, 2” pleated, three 20” x 20”and two 16” x 25” nominal size

Weight: 775 lbs (unit), 830 lbs (shipping weight)

Shipping Dimensions: 72” W x 84” L x 50” H

Blower RPM Nominal Turns Open

Static Pressure in Adjacent Air Handler (Inches Water Column)-0.5 -0.25 0.0 +0.25 +0.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

Exhaust Air

1,520 0 - - - - - - - - - -

1,465 1 2,130 2.9 - - - - - - - -

1,405 2 2,000 2.5 2,245 2.8 2,455 3.0 - - - -

1,345 3 1,915 2.3 2,135 2.6 2,345 2.7 2,475 2.8 2,575 2.9

1,285 4 1,725 1.8 1,950 2.1 2,180 2.3 2,345 2.4 2,455 2.5

Fresh Air

1,800 0 2,565 3.0 2,385 2.9 2,225 2.8 2,065 2.7 1,830 2.4

1,740 1 2,480 2.8 2,290 2.7 2,150 2.6 1,975 2.5 1,740 2.2

1,680 2 2,375 2.6 2,210 2.5 2,070 2.4 1,910 2.3 1,645 2.0

1,620 3 2,290 2.4 2,125 2.4 1,990 2.3 1,825 2.1 1,555 1.8

1,560 4 2,200 2.1 2,040 2.1 1,910 2.0 1,725 1.9 1,450 1.5

SpecificationsOutdoor Unit

G5 Performance

Airflow Performance

CFM1,500 2,000 2,500 3,000

80

60

40

SensibleWinter Total

Summer Total

Effe

ctiv

enes

s (%

)

*At AHRI 1060 standard conditions(See certified data on page 67 for core components).

Page 51: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com49

HE3X

RTC

Un

it D

imen

sio

ns

Fron

t Vie

wLe

ft Vi

ew

RAFA

Bac

k Vi

ew

EA

OA

EA

FA

OA

EARA RAFA

RAFA

OA

EA

120"

Ser

vice

Are

a

83 7

/8"

Ser

vice

Are

a

6 1/

2" 25 1

/2"

45"

57 1

/2"

81 1

/4"

Rig

ht V

iew

Cor

e an

d E

A B

low

er A

cces

s

OA

Blo

wer

and

Fi

lter A

cces

s

33 1

/8"57

"74

1/2

"

40"

42"

45"

28 1

/4"

Wiri

ng In

7/8"

Dia

.

E-b

ox A

cces

s

OA

Blo

wer

and

Filte

r Acc

ess

RA

Filte

r Acc

ess

EA

Blo

wer

Acc

ess

29"

Top

View

OA

36 3

/8"

Ser

vice

Are

a

61 3

/4"

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 52: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282450

HE4XRT

Motor HP Blower RPM Nominal Turns Open

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

21,0101,2101,370

4.520

2,489 0.92,995 1.6 - -

2,200 0.92,290 1.5 - -

1,715 0.82,430 1.4 - -

1,100 0.72,005 1.32,600 2.0

- -1,540 1.22,215 1.9

- - - -1,800 1.7

- - - -1,100 1.5

31,3451,5351,685

4.520

3,295 2.13,832 2.9 - -

3,145 2.13,682 2.9 - -

2,840 2.03,480 2.8 - -

2,509 1.93,170 2.6 - -

2,116 1.82,839 2.43,409 3.0

1,747 1.62,449 2.33.003 2.8

1,135 1.51,878 2.02,465 2.4

51,4951,6751,855

630

3,718 2.74,223 3.8 - -

3,568 2.64,083 3.7 - -

3,345 2.63,943 3.6 - -

3,030 2.43,659 3.44,287 4.9

2,686 2.23,364 3.24,011 4.6

2,301 2.12,994 2.93,760 4.3

1,722 1.92,490 2.73,434 4.0

Outdoor Unit

G5 Performance

Airflow Performance

CFM1,000 2,000 3,000 4,000

80

60

40

SensibleWinter Total

Summer Total

Effe

ctiv

enes

s (%

)

*At AHRI 1060 standard conditions(See certified data on page 67 for core components).

SpecificationsVentilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 1,000-4,400 CFM

AHRI 1060 Certified Core: Four L125-00

Airflow Rating Points (for AHRI): 3,000 CFM and 2,250 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

2

208-230208-230

460575

60606060

SingleThreeThreeThree

11.3-10.56.2-6.2

3.52.3

25.414.07.95.2

35201515

3

208-230208-230

460575

60606060

SinlgeThreeThreeThree

13.79.2-8.6

4.33.2

30.820.79.77.2

45301515

5208-230

460575

606060

ThreeThreeThree

14.0-13.06.55.0

31.514.611.3

452015

Control Voltage: 24 VAC

Filters: Eight total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 915 lbs (unit), 1,000 lbs (shipping weight)

Shipping Dimensions: 84” W x 92” L x 49” H

OA

RAFA

EA

RTV

OA

RA

FA

EA

RTF

Base Type/Airflow Orientations

OA

RA

EA

FA

RTR

OA

RA

EA

FA

RTH

Page 53: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com51

CURB

4X

HE4X

RT

Un

it D

imen

sio

ns

Left

View

Fron

t Vie

w

Rig

ht V

iew

Top

View

RA

OA

RA

FA

FA

117

1/4"

Ser

vice

Are

a

RA

(RTV

, RTR

Onl

y)11

" x 4

6"

12 1/4" 14 3/4"

17 3

/4"

18 5

/8"

28 3

/4" C

urb

Cen

ter

40 1

/8"

Cur

b C

ente

r

64 1

/2" S

ervi

ce A

rea

40 3

/8"

4"

5 1/8"

12" X

40"

RA

Inle

t(R

TH, R

TF)

82" O

vera

ll

4"Top of Curb

OA

Inle

t

80"

89 3

/4" O

vera

ll

9"

57"

2"

21 3

/4"

12" X

32"

FA O

utle

t(R

TH, R

TR)

EA

Out

let

40 3

/8" 5 1/2"

77 3

/4" P

ower

Wire

Inle

t74

3/4

" Con

trol W

ire In

let

38 3

/4"

18 5/8"

Wiri

ng In

7/8"

Dia

.

E-b

ox

EA

12" X

32"

FA (R

TV, R

TF)

55 1

/4" l

ift lu

gs79

3/4

" lift

ing

lugs

82 1

/4"

Uni

t

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 54: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282452

HE4XRTC

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 2,500-3,700 CFM

AHRI 1060 Certified Core: Four L125-00

Airflow Rating Points (for AHRI): 3,000 CFM and 2,250 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

5208-230

460575

606060

ThreeThreeThree

14.0-13.06.55.0

31.514.611.3

452015

Control Voltage: 24 VAC

Filters: Six total, MERV 8, 2” pleated, four 20” x 20”, and two 16” x 25” nominal size

Weight: 965 lbs (unit), 1,050 lbs (shipping weight)

Shipping Dimensions: 84” W x 92” L x 50” H

SpecificationsOutdoor Unit

Blower RPM

Nominal

Turns Open

Static Pressure in Adjacent Air Handler (Inches Water Column)-0.5 -0.25 0.0 +0.25 +0.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

Exhaust Air

1,600 0 3,700 3.6 4,000 3.8 4,250 4.3 - - - -

1,555 1 3.575 3.5 3.900 3.6 4,220 3.9 4,325 4.3 4,380 4.6

1,515 2 3,415 3.2 3,740 3.5 4,135 3.8 4,275 4.2 4,340 4.5

1,470 3 3,235 2.9 3,600 3.2 4,000 3.6 4,215 4.0 4,300 4.3

1,430 4 3,085 2.7 3,455 3.0 3,820 3.2 4,140 3.6 4,260 3.8

1,385 5 2,980 2.5 3,280 2.7 3,640 2.9 3,985 3.2 4,170 3.4

1,340 6 2,880 2.3 3,135 2.5 3,475 2.7 3,840 2.9 4,080 3.0

Fresh Air

1,805 1 - - - - - - - - 3,210 4.9

1,755 2 - - - - 3,410 4.9 3,190 4.6 3,110 4.3

1,705 3 3,710 5.0 3,585 4.9 3,310 4.5 3,130 4.2 3,010 3.9

1,655 4 3,600 4.8 3,470 4.6 3,210 4.2 3,030 3.8 2,910 3.6

1,605 5 3,510 4.3 3,335 4.1 3,110 3.7 2,920 3.4 2,800 3.2

1,555 6 3,400 3.9 3,220 3.8 3,010 3.4 2,810 3.2 2,710 3.0

G5 Performance

Airflow Performance

CFM1,000 2,000 3,000 4,000

80

60

40

SensibleWinter Total

Summer Total

Effe

ctiv

enes

s (%

)

*At AHRI 1060 standard conditions(See certified data on page 67 for core components).

Page 55: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com53

HE4X

RTC

Un

it D

imen

sio

ns

80 3

/4"

82 1

/4" S

ervi

ce A

rea

OA

Blo

wer

and

Fi

lter A

cces

s

Cor

e an

d E

AB

low

er A

cces

s

RAFA

OAOA

EA

139

1/2"

Ser

vice

Are

a EAOA

57 1

/2"

81 3

/4"

5 1/

2"

Rig

ht V

iew

25 1

/2"

6 1/

2"

RAFA

RAFA45

"

RAFA

40"

42"

33 1

/8"

57"

74 1

/2"

11 1

/4" t

yp

37"

E-b

ox A

cces

s

OA

Blo

wer

and

Filte

r Acc

ess

Wiri

ng In

7/8"

Dia

.

EA

Blo

wer

Acc

ess

RA

Filte

rA

cces

s

Fron

t Vie

wLe

ft Vi

ewB

ack

View

Top

View

46 1

/2"

OA

36 3

/8"

Ser

vice

Are

a

EAEA

82 1

/4"

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 56: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282454

HE6XRT

Motor HP Blower RPM Nominal Turns Open

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

51,4601,6101,725

4.520

5,005 3.25,550 4.2 - -

4,800 3.25,375 4.2 - -

4,650 3.15,250 4.1 - -

4,475 3.05,100 4.15,525 5.0

4,200 2.94,900 4.05,475 5.0

4,000 2.84,650 3.95,200 4.9

3,750 2.84,500 3.85,050 4.8

7.51,5601,7401,865

4.520

5,275 3.75,950 5.06,500 6.5

5,200 3.65,825 5.06,350 6.5

4,900 3.55,625 4.96,225 6.4

4,775 3.55,490 4.96,125 6.4

4,550 3.45,325 4.85,910 6.3

4,350 3.35,125 4.75,825 6.2

4,125 3.34,950 4.75,625 6.1

SpecificationsOutdoor Unit

G5 Performance

Airflow Performance

CFM3,000 4,000 5,000 6,000

80

60

40

SensibleWinter Total

Summer Total

Effe

ctiv

enes

s (%

)

*At AHRI 1060 standard conditions(See certified data on page 67 for core components).

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 1,500-6,500 CFM

AHRI 1060 Certified Core: Six L125-00

Airflow Rating Points (for AHRI): 4,500 CFM and 3,375 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

5208-230

460575

606060

ThreeThreeThree

14.2-13.06.55.0

32.614.911.3

452015

7.5208-230

460575

606060

ThreeThreeThree

20.9-19.29.67.6

47.021.617.1

703025

Control Voltage: 24 VAC

Filters: Twelve total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 2,340 lbs (unit), 2,640 lbs (shipping weight)

Shipping Dimensions: 85” W x 114” L x 85” H

OA

RAFA

EA

RTV

OA

RA

FA

EA

RTF

Base Type/Airflow Orientations

OA

RA

EA

FA

RTR

OA

RA

EA

FA

RTH

Page 57: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com55

CURB

6X

HE6X

RT

Un

it D

imen

sio

ns

62"

34" Min.Clearance

112

3/4"

Uni

t Roo

f

108

1/2"

Bas

e

78 1/4" Overall

49"

81 1

/2" B

ase

24"

108

1/2"

Bas

e

EA

18"

39 1

/2" M

in.

Cle

aran

ce

85 1

/2" U

nit R

oof

160

1/4"

Ser

vice

Are

a

165" Service Area

12"41 3/4"

FRO

NT

VIE

WB

low

er A

cces

sB

AC

K V

IEW

LEFT

VIE

W

RIG

HT

VIE

W

4"9"

24"77"

4"22"

36"

TOP

VIE

W

(RTF

,RTH

Onl

y)

(RTV

,RTR

)

RA

RA

FA

FA

Pow

er a

ndC

ontro

lW

iring

Ent

ries

7/8"

Dia

.

Pow

er a

nd C

ontro

l Wiri

ng E

ntrie

s

OA

EA

Cor

eA

cces

s

RTH

, RTR

UN

ITS

ON

LY:

FA B

LOW

ER

Out

let i

s 18

" x 2

4".

24" x

36"

Duc

t Fla

nge

is a

lso

supp

lied .

Fiel

d in

stal

l onl

y in

loca

tion

show

n.

RTV

, RTF

UN

ITS

ON

LY:

FA B

low

er O

utle

t is

16" x

22"

.C

urb

acce

pts

up to

24"

x 3

6" d

uct;

see

sepa

rate

Cur

b dr

awin

g.

63 1

/2"

39 3/4"

Fron

t Vie

ws

at 0

.5X

:B

LOW

ER

RO

TATI

ON

21 7

/8"

EAEA

59 3

/8"

60 7/8"

Not

e:A

ll un

its h

ave

an in

tegr

alex

haus

t air

back

draf

t dam

per.

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 58: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282456

HE8XRT

Ventilation Type: Static Plate, Heat and Humidity Transfer

Typical Airflow Range: 2,000-8,000 CFM

AHRI 1060 Certified Core: Eight L125-00

Airflow Rating Points (for AHRI): 6,000 CFM and 4,500 CFM

Number Motors: Two

HP Volts HZ Phase FLAMin. Cir.

Amps

Max. Fuse Size

5208-230

460575

606060

ThreeThreeThree

14.2-13.06.55.0

32.614.911.3

452015

7.5208-230

460575

606060

ThreeThreeThree

20.9-19.29.67.6

47.021.617.1

703025

10208-230

460575

606060

ThreeThreeThree

29.0-26.813.410.0

65.330.222.5

904535

Control Voltage: 24 VAC

Filters: Sixteen total, MERV 8, 2” pleated, 20” x 20” nominal size

Weight: 2,730 lbs (unit), 3,080 lbs (shipping weight)

Shipping Dimensions: 85” W x 114” L x 85” H

CFM2,000 4,000 6,000 8,000

80

60

40

SensibleWinter Total

Summer Total

SpecificationsOutdoor Unit

G5 Performance

Motor HP Blower RPM Nominal Turns Open

External Static Pressure (Inches Water Column)

0.0 0.25 0.5 0.75 1.0 1.25 1.5

CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP

51,4601,6101,725

4.52

0.5

5,575 3.26,200 4.36,550 5.0

5,425 3.26,010 4.36,380 5.0

5,200 3.25,875 4.26,210 5.0

5,000 3.25,700 4.26,100 5.0

4,775 3.15,500 4.25,880 4.9

4,550 3.05,325 4.15,730 4.8

4,270 2.95,125 4.15,510 4.8

7.51,5601,7401,865

4.520

6,000 3.96,700 5.3 - -

5,850 3.96,575 5.3 - -

5,650 3.86,400 5.3 - -

5,475 3.86,300 5.36,800 7.5

5,275 3.86,125 5.36,675 7.5

5,100 3.75,950 5.26,500 7.5

4,875 3.75,750 5.26,375 7.4

101,8102,0202,105

4.521

7,000 6.17,850 8.5 - -

6,875 6.17,745 8.5 - -

6,750 6.17,625 8.57,950 9.6

6,600 6.07,450 8.47,800 9.6

6,425 6.07,350 8.47,725 9.6

6,275 6.07,200 8.37,600 9.5

6,100 5.97,050 8.37,450 9.5

Airflow Performance

Effe

ctiv

enes

s (%

)

*At AHRI 1060 standard conditions(See certified data on page 67 for core components).

OA

RAFA

EA

RTV

OA

RA

FA

EA

RTF

Base Type/Airflow Orientations

OA

RA

EA

FA

RTR

OA

RA

EA

FA

RTH

Page 59: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com57

62"

34" Min.Clearance

112

3/4"

Uni

t Roo

f

108

1/2"

Bas

e

78 1/4" Overall

27 1

/4"

49"

81 1

/2" B

ase

24"

29"

OA

108

1/2"

Bas

e

OA

39 1

/2" M

in.

Cle

aran

ce

85 1

/2" U

nit R

oof

183

1/4"

Ser

vice

Are

a

165" Service Area

35"

41 3/4"

FRO

NT

VIE

WB

low

er A

cces

sB

AC

K V

IEW

LEFT

VIE

W

RIG

HT

VIE

W

4"

77"

4"22"36"

TOP

VIE

W

(RTF

,RTH

Onl

y)

(RTV

,RTR

)

RA

RA

Pow

er a

ndC

ontro

lW

iring

Ent

ries

7/8"

Dia

.

OA

Cor

e A

cces

s

RTH

, RTR

UN

ITS

ON

LY:

FA B

LOW

ER

Out

let i

s 18

" x 2

4".

24" x

36"

Duc

t Fla

nge

is a

lso

supp

lied .

Fiel

d in

stal

l onl

y in

loca

tion

show

n.

24"

FA

Fron

t Vie

ws

@ 0

.5X

:B

LOW

ER

RO

TATI

ON

RTV

, RTF

UN

ITS

ON

LY:

FA B

low

er O

utle

t is

16" x

22"

.C

urb

acce

pts

up to

24"

x 3

6" d

uct;

see

sepa

rate

Cur

b dr

awin

g.

18"

9"

39 3/4"

63 1

/2"

FA

OA

Hoo

ds o

nR

oofto

p U

nits

on

ly.

EA

21 7

/8"

EA

EA

Pow

er a

nd C

ontro

l Wiri

ng E

ntrie

s

EA59

3/8

"

60 7/8"

Not

e:A

ll un

its h

ave

an in

tegr

alex

haus

t air

back

draf

t dam

per.

CURB

8X

HE8X

RT

Un

it D

imen

sio

ns

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

Page 60: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282458

CA4X

Applied Products

Cost effective energy recovery for virtually • any air handling system.

Field assembled into air handling systems • or integrated in custom packaged air handlers.

Unlimited airflow capacity.•

Flexible installation and easy servicing.•

AHRI certified performance data for • efficiency and cross leakage.

UL tested flammability and • smoke generation that meets NFPA 90A and 90B test standards for commercial applications.

Ten year core warranty.•

RenewAire means Trouble-Free ERV.

Similar designs can use PA-Series arrays. (PA-Series provide top service access and an “over-under” airflow arrangement.)

Central Air Handler using CA4X and exhaust and make-up air blowers. (CA-Series provide side service access and a “side-by-side” airflow arrangement.)

Installation Example

Page 61: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com59

Part I - General

A. Product Specification

1. Energy Recovery Ventilator (ERV) shall be a packaged unit as manufactured by RenewAire and shall transfer both heat and humidity using static plate core technology. B. Quality Assurance

1. The energy recovery cores used in these products shall be third party Certified by AHRI under its Standard 1060 for Energy Recovery Ventilators. AHRI published certifications shall confirm manufacture’s published performance for airflow, static pressure, temperature and total effectiveness, purge air (OACF) and exhaust air leakage (EATR). Products that are not currently AHRI Certified will not be accepted.

2. The energy recovery core shall be a UL Listed Component complying to UL Standard 723. Manufacturer shall be able to provide evidence of independent testing of the core by Underwriters Laboratory (UL), verifying a maximum flame spread index (FSI) of 25 and a maximum smoke developed index (SDI) of 50 thereby meeting NFPA 90A and NFPA 90B requirements for materials in a compartment handling air intended for circulation through a duct system.

3. The ERV core shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of ten years from the date of purchase. The balance-of-unit shall be warranted to be free of manufacturing defects and to retain its functional characteristics, under circumstances of normal use, for a period of two years from the date of purchase.

Part II – Performance

A. Energy TransferThe ERV shall be capable of transferring both sensible and latent energy between airstreams. Latent energy transfer shall be accomplished by direct water vapor transfer from one airstream to the other, without exposing transfer media in succeeding cycles directly to the exhaust air and then to the fresh air.

B. Passive Frost ControlThe ERV core shall perform without condensing or frosting under normal operating conditions (defined as outside temperatures above -10°F and inside relative humidity below 40%). Occasional more extreme conditions shall not affect the usual function, performance or durability of the core. No condensate drains will be allowed.

C. Continuous VentilationUnit shall have the capacity to operate continuously without the need for bypass, recirculation, pre-heaters or defrost cycles under normal operating conditions.

D. Positive Airstream SeparationWater vapor transfer shall be through molecular transport by hydroscopic resin and shall not be accomplished by “porous plate” mechanisms. Exhaust and fresh airstreams shall travel at all times in separate passages, and airstreams shall not mix.

E. Laminar FlowAirflow through the ERV core shall be laminar over the products entire operating airflow range, avoiding deposition of particulates on the interior of the energy exchange plate material.

Part III – Product

A. Construction

1. The energy recovery component shall be of fixed-plate cross-flow construction, with no moving parts.

2. No condensate drain pans or drains shall be allowed and unit shall be capable of operating in both winter and summer conditions without generating condensate.

3. The unit case shall be constructed of G90 galvanized, 20-gauge steel, with lapped corners and zinc plated screw fasteners.

4. Access doors shall provide easy access to ERV cores and filters. Doors shall have an airtight compression seal using closed cell foam gaskets.

5. Case walls and doors shall be insulated with 1 inch, 4 pound density, foil/scrim faced, high-density fiberglass board insulation, providing a cleanable surface and eliminating the possibility of exposing the fresh air to glass fibers. PA-Series bottom panels shall be insulated with ¼ inch sheet rubber insulation.

6. The ERV cores shall be protected by a MERV-8 rated, 2” nominal, pleated, disposable filter in both airstreams.

7. CA-Series cabinet construction shall allow stacking of units up to three cabinets high for larger airflow applications. Hinged and latched access doors will be provided on each end of the unit.

8. PA-Series shall use RenewAire patented modular vertical stack of cores (US Patent 5,660,228) allowing assembly of unlimited sizes of ERV systems. Latched access doors are provided on the top of each unit. B. Options (Select options based on application requirements)

1. Provide unit and duct connection orientation per project schedule.

2. Provide double wall construction with 24-gauge galvanized steel liner (CA-Series only).

3. CA and PA-Series units are available pre-assembled on a structural steel base.

Part IV – Installation

A. Unit Location

1. Locate and orient unit to provide the shortest and most straight duct connections. Provide service clearances as indicated on the plans. Locate system blowers (provided by others) distant from sound critical occupancies.

2. Provide a poured concrete equipment pad for all floor mounted units. The pad thickness, and floor plan dimensions to be determined based on the unit selected, and site structural considerations.

3. Provide a structurally suitable support for the base of any wall mounted or hung units.

B. Vibration Isolation

1. No moving parts are allowed in the ERV modular assemblies.

C. Duct Design

1. All ductwork shall be designed, constructed, supported and sealed in accordance with SMACNA HVAC Duct Construction Standards and pressure classifications.

2. At a minimum all duct runs to the outdoors shall be thermally insulated at levels appropriate to the local climate. A continuous vapor barrier shall also be provided on warm surface of the insulation.

D. Sound Control

1. The ERV cores shall act as flow straighteners and sound attenuators. This attribute can be used to isolate mechanical noise from blowers and other mechanical equipment from sound critical occupancies.

E. Test and Balancing

1. Test and Balancing may not begin until 100% of the installation is complete and fully functional.

2. Follow National Comfort Institute (NCI) air test and balance procedures specific to Heat Recovery Ventilator Balancing Procedure including standard reports to the owner’s representative.

CA & PA Series Applied Energy Recovery Ventilators: CA2X, CA3X, CA4X, PA6X, PA9X, PA8X & PA12X

Page 62: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282460

CA-Series

Ventilation Type: Static Plate, Heat and Humidity Transfer

Insulated sheet metal cabinets with energy exchange cores and filters.

Individual CA-Series units or stacks of units can be built into larger air handling systems.

Blower not included and must be specified to meet job requirements.

Description CA2X CA3X CA4X

Typical Airflow Range CFM 500-2,200 750-3,300 1,000-4,400

AHRI 1060 Certified Core Two L125-00 Three L125-00 Four L125-00

Airflow Rating Points (for AHRI)

1,500 and1,120 CFM

2,250 and 1,690 CFM

3,000 and 2,250 CFM

Unit Weight 225 lbs 325 lbs 400 lbs

Shipping Weight 275 lbs 375 lbs 475 lbs

Filters: MERV 8, 2” pleated 20” x 20” nominal size Four Total Six Total Eight Total

Shipping Dimensions: CA2X - 40” W x 48” L x 41” H CA3X - 40” W x 67” L x 41” H CA4X - 40” W x 87” L x 41” H

Insulation: One inch, high density, FSK faced, fiberglass

CFM

500 1,000 1,500 2,000

80

60

40

Effe

ctiv

enes

s (%

)

SensibleWinter TotalSummer Total

CA2X

CFM

1,000 2,000 3,000 4,000

80

60

40

Effe

ctiv

enes

s (%

)

SensibleWinter TotalSummer Total

CA4X

CFM

1,250 1,750 2,250 2.750

80

60

40

Effe

ctiv

enes

s (%

)

SensibleWinter TotalSummer Total

CA3X

CA3X

2.0

1.5

1.0

0.5

1,000 2,000 3,000 4,000

Airflow (CFM)

Inte

rnal

Sta

tic

Pres

sure

(in.

H2O

)

CA2X

CA3X

CA4X

SpecificationsIndoor Unit - Up to 20,000 CFM in Stacked Arrays

G5 Performance

Airflow Performance

*At AHRI 1060 standard conditions(See certified data on page 66 for core components).

Page 63: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com61

CA

-SERIE

SU

nit

Dim

en

sio

ns Le

ft Vi

ew

B

F

A

34 3

/4"

BF

E

34 3/4"

End

Vie

w15"

1"R

ight

Vie

w

E

34 3/4"

15"1"

D (

Min

imum

Ser

vice

Are

a)

2.50

00

39 3/4"

C (M

axim

um S

ervi

ce A

rea)

2.50

00

Not

e: F

ilter

s ar

e pr

ovid

ed fo

r ins

talla

tion

in

any

two

of th

e lo

catio

ns s

how

n, d

epen

ding

on

whi

ch d

uct c

onne

ctio

ns a

re s

elec

ted

for

inle

ts.

Filte

rs a

re 2

" x 2

0" x

20"

ple

ated

di

spos

able

.

Top

View

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

CA2X

CA3X

CA4X

A42

”62

”81

-5/8

”B

14”

24”

32”

C11

1”13

0”14

9”D

77”

96”

116”

E5-

5/8”

5-5/

8”7-

5/8”

F19

-3/4

”29

-5/8

”39

-3/4

Avai

labl

e O

ptio

ns:

Dou

ble

Wal

l Con

stru

ctio

n

Page 64: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282462

Ventilation Type: Static Plate, Heat and Humidity Transfer

Insulated sheet metal panels easily slide into receivers to enclose stacks of energy exchange cores using unique patented design, US Patent 5,660,228

Individual PA-Series units can be joined together to provide unlimited airflow capacities for larger air handling systems.

Blower not included and must be specified to meet job requirements.

Description PA6X PA8X PA9X PA12X

Typical Airflow Range CFM 1,500-6,600 2,000-8,800 2,250-9,900 3,000-13,200

AHRI 1060 Certified Core Six L125-00 Eight L125-00 Nine L125-00 Twelve L125-00

Airflow Rating Points (for AHRI)

4,500 and 3,375 CFM

6,000 and 4,500 CFM

6,750 and 5,062 CFM

9,000 and 6,750 CFM

Unit Weight 565 lbs 695 lbs 800 lbs 980 lbs

Shipping Weight 650 lbs 900 lbs 990 lbs 1,180 lbs

Filters: MERV 8, 2” pleated, 20” x 20” nominal size PA6X - 12 Total PA9X - 18 Total PA8X - 16 Total PA12X - 24 Total

Insulation: One inch, high density, FSK faced, fiberglass

3,500 5,000 6,500 8,000

80

60

40

Effe

ctiv

enes

s (%

)

Sensible

Summer TotalPA8X

3,000 4,000 5,000 6,000

80

60

40

Effe

ctiv

enes

s (%

)

Sensible

Winter TotalSummer Total

PA6X

5,000 7,000 9,000 11,000

80

60

40

Effe

ctiv

enes

s (%

)

Sensible

Summer TotalPA12X

3,500 5,000 6,500 8,000

80

60

40

Effe

ctiv

enes

s (%

)

Sensible

Winter TotalSummer Total

PA9X

Winter Total

CA3X

2.0

1.5

1.0

0.5

3,000 6,000 9,000 12,000

Airflow (CFM)

Inte

rnal

Sta

tic

Pres

sure

(in.

H2O

)

PA6X

PA12

XPA9XPA8X

Winter Total

CFM

CFM

CFM

CFM

PA-SeriesSpecificationsIndoor Unit - Unlimited Airflow in Multiple Arrays

G5 Performance

Airflow Performance

*At AHRI 1060 standard conditions(See certified data on page 66 for core components).

Page 65: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com63

PA

-SERIE

SU

nit

Dim

en

sio

ns

PA-9

X/1

2X

35 1

/2"

A =

109

1/2

Top

View

35 1

/2"

2

1 2

1

Arr

ange

men

t 4S

ame-

side

Ent

ries

Par

alle

l-pat

h A

irflo

ws

35 1

/2"

1 2

1 2

Arr

ange

men

t 3O

ppos

ite-s

ide

Ent

ries

Par

alle

l-pat

h A

irflo

ws

35 1

/2"

21 2

1

Arr

ange

men

t 2S

ame-

side

Ent

ries

Cro

ss-p

ath

Airf

low

s

35 1

/2"

1 212

Opp

osite

-sid

e E

ntrie

sC

ross

-pat

h A

irflo

ws

Arr

ange

men

t 1

PA-6

X/8

X

35 1

/2"

A =

73 1

/4

Avai

labl

e A

irflow

Arr

ange

men

ts(S

ide

View

s)

Perf

orm

ance

Der

atin

g:A

irflow

arr

ange

men

ts 3

& 4

resu

lt in

low

er e

nerg

y tr

ansf

er.

Redu

ce s

ensi

ble

effec

tiven

ess

by 2

per

cent

age

poin

ts.

Redu

ce to

tal e

ffect

iven

ess

by 1

per

cent

age

poin

t.S

ide

View

Ser

vice

A

rea

35 1

/2"

22 1

/2”

A (O

vera

ll)

Fron

t Vie

w

Ser

vice

Are

a

G

EE

D (D

uct F

lang

e)

F 5”

EA:

Exh

aust

Air

to

outd

oors

OA:

Out

door

Air

inta

keRA

: R

oom

Air

to

be e

xhau

sted

FA:

Fre

sh A

ir t

o in

side

PA6X

PA9X

PA8X

PA12

XA

73-1

/4”

109-

1/2”

73-1

/4”

109-

1/2”

D72

-3/4

”10

9”72

-3/4

”10

9”E

28”

28”

37”

37”

F1-

1/2”

1-1/

2”3-

1/8”

3-1/

8”G

66-1

/4”

66-1

/4”

86”

86”

APPR

OX.

WEI

GH

T56

581

070

010

00

Avai

labl

e O

ptio

ns:

Knoc

kdow

n

Asse

mbl

ed o

n st

ruct

ural

fo

rklif

t ba

se

Page 66: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282464

These controls are intended to turn RenewAire commercial energy recovery ventilation systems on and off at appropriate times. Specification, installation and set-up is an easy process. RenewAire units should be ordered with the 24 volt contactor option for all controls.

It is not necessary that RenewAire controls be used to operate RenewAire units. A wide range of controls or building automation systems may be used. Make sure units are ordered with compatible contactor control voltage.

RenewAire residential units have their own line of compatible controls that are not intended to operate RenewAire commercial units.

TC7D-WWall Mount

TC7D-E ControlIn NEMA 3R Enclosures

MC-CCeiling Mount

MC-WWall Mount

CO2-WWall Mount

CO2-DDuct Mount

Commercial Controls & Interconnection Options

TC7D

MC

CO2

Digital Time Clock

Motion (occupancy) Control

Carbon Dioxide Control

up to 8 on/off cycles per day or 56 per week• 24 VAC power requirement• battery back-up• wall mount or outdoor enclosure options• wall mount fits any 4” x 4” electrical box• optional RenewAire transformer relay • package (TR40) may be used

passive infared sensor• adjustable time-off delay to 30 minutes• 24 VAC power requirement• ceiling mount or directable wall mount• covers up to 1500 sq. ft. floor space • ceiling mount - walking motion coverage up to 22 foot radius wall mount - various coverage patterns up to 90 linear feet of sensitivity

requires the use of RenewAire transformer relay package • (TR40) (ordered separately)

adjustable control from 600-2000 PPM• digital display• 24 VAC power requirement• computer/BAS interface for information and control• self calibrates during periods of low occupancy• wall mount or add duct mount accessory• requires the use of RenewAire transformer relay package • (TR40) (ordered separately)

Page 67: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com65

DH24Wall Mount

DS

TR40

IBC

DH24

Disconnect Switch

Transformer Relay Package

Independent Blower Control

Dehumidistat Control

provides a 24 VAC, 40 VA class II power supply for unit control• includes isolation relay with low voltage circuit breaker• handles any RenewAire unit with one contactor• installation voltage must be specified 115, 208-230, 460• installed in unit electric box• TR40 is configured as part of the model numbering for a unit (see page 67)•

adds a second contactor to allow independent control of exhaust fan and • supply fanmay be used to provide economizer (no heat recovery operation) function• can provide relief fan or make-up air function to benefit building pressurization• IBC is configured as part of the model numbering guide for a unit (see page 67)•

fused or non-fused• indoor or NEMA 3R exterior enclosures - I or E• installation voltage must be specified 115, 208-230, 460• installed on unit and wired to unit contactor• disconnects are configured as part of the model numbering for a unit (see page 67)•

secondary control to time clock or other primary control• mechanical switching of 24 VAC (or 120 VAC)• adjustable from 0 - 100% relative humidity• wall mount to single gang box• Note: RenewAire ERVs are not to be used for applications • where indoor relative humidity exceeds 50% RH for extended periods of time

Page 68: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

(800) 627-4499 • Fax: (608) 221-282466

HVI Tested/CertifiedPer CSA C439

Electrical Requirements Volts 120 Amps 3.3Exhaust Air Transfer Ra�o = 4% @ 0.4 in. wg (100 PA)

Electrical Requirements Volts 120 Amps 1.5Exhaust Air Transfer Ra�o = 3% @ 0.2 in. wg (50 PA) and 3% @ 0.4 in. wg (100 PA)

Electrical Requirements Volts 120 Amps 1.3Exhaust Air Transfer Ra�o = 2% @ 0.2 in. wg (50 PA) and 2% @ 0.4 in. wg (100 PA)

Electrical Requirements Volts 120 Amps 1.0Exhaust Air Transfer Ra�o = 4% @ 0.2 in. wg (50 PA) and 4% @ 0.4 in. wg (100 PA)

EV300 - Ventilation Performance

Ext. Static Pressure Net Supply AirflowGross Airflow

Supply ExhaustPa in. wg L/S CFM L/S CFM L/S CFM100 0.4 145 310 150 320 143 305125 0.5 141 300 145 310 138 295150 0.6 136 289 140 299 127 270175 0.7 126 268 130 276 114 242200 0.8 117 249 121 251 92 195225 0.9 94 199 97 206 79 169250 1.0 73 155 75 160 65 138

EV300 - Energy PerformanceSupply

Temperature Net Airflow Average Power Watts

Sensible Recovery Efficiency %

Apparent Sensible Effectiveness %

Net Moisture Transfer %

C° F° L/S CFM Heating

0° 32° 138 293 310 68 76 45 Cooling Total Recovery Efficiency %

35° 95° 120 272 299 38

EV200 - Energy PerformanceSupply

Temperature Net Airflow Average Power Watts

Sensible Recovery Efficiency %

Apparent Sensible Effectiveness %

Net Moisture Transfer %

C° F° L/S CFM Heating

0° 32° 85 181 157 78 85 62 Cooling Total Recovery Efficiency %

35° 95° 85 180 155 52

EV200 - Ventilation Performance

Ext. Static Pressure Net Supply AirflowGross Airflow

Supply ExhaustPa in. wg L/S CFM L/S CFM L/S CFM25 0.1 97 207 100 213 109 23250 0.2 90 192 93 199 104 22175 0.3 88 186 90 192 101 216100 0.4 83 176 85 181 96 204125 0.5 79 168 81 173 88 187150 0.6 70 149 72 154 76 162175 0.7 57 122 59 126 68 145

BR130/EV130 - Energy PerformanceSupply

Temperature Net Airflow Average Power Watts

Sensible Recovery Efficiency %

Apparent Sensible Effectiveness %

Net Moisture Transfer %

C° F° L/S CFM Heating

0° 32° 58 124 121 72 80 55 Cooling Total Recovery Efficiency %

35° 95° 59 126 121 46

BR130/EV130 - Ventilation Performance

Ext. Static Pressure Net Supply AirflowGross Airflow

Supply ExhaustPa in. wg L/S CFM L/S CFM L/S CFM25 0.1 70 148 71 151 75 15950 0.2 66 141 67 143 69 14775 0.3 62 132 63 134 64 135100 0.4 53 113 54 115 56 119125 0.5 44 94 45 96 47 99150 0.6 32 69 33 70 29 62175 0.7 24 52 25 53 21 45

BR70/EV70 - Energy PerformanceSupply

Temperature Net Airflow Average Power Watts

Sensible Recovery Efficiency %

Apparent Sensible Effectiveness %

Net Moisture Transfer %

C° F° L/S CFM Heating

0° 32° 32 69 94 66 77 53 Cooling Total Recovery Efficiency %

35° 95° 30 64 94 42

BR70/EV70 - Ventilation Performance

Ext. Static Pressure Net Supply AirflowGross Airflow

Supply ExhaustPa in. wg L/S CFM L/S CFM L/S CFM25 0.1 41 86 42 89 46 9750 0.2 34 73 35 75 39 8475 0.3 28 59 29 61 32 69100 0.4 21 46 22 47 25 53

0 50 100 150 200 250 300 350

in.

wg.

(PA

= n

x 2

48.8

)

1.11.00.90.80.70.60.50.40.30.20.10.0

CFM (L/S = n x 0.4719)

Gross Supply Gross Exhaust

0 25 50 75 100 125 150 175 200 225 250

in.

wg.

(PA

= n

x 2

48.8

)

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0

CFM (L/S = n x 0.4719)

Gross Supply Gross Exhaust

0 25 50 75 100 125 150 175

in.

wg.

(PA

= n

x 2

48.8

)

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0

CFM (L/S = n x 0.4719)

Gross Supply Gross Exhaust

0 25 50 75 100 125 150 175

in.

wg.

(PA

= n

x 2

48.8

)

0.9

0.8

0.7

0.6

0.5

0.4

0.3

0.2

0.1

0.0

CFM (L/S = n x 0.4719)

Gross Supply Gross Exhaust

Page 69: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

www.RenewAire.com67

AHRI 1060-2005Certified Performance

Leakage Ratings

Pressure Differential EATR OACF Purge Angle

or Setting

Test 1 -1 in. H20 1.0% 1.00 N/A

Test 2 0 in. H20 0.0% 1.02 N/A

Test 3 1 in. H20 0.0% 1.05 N/A

AHRI-1060 Certified Performance - Model Number L85-G5

Type Tilt Angle Nominal Airflow Pressure Drop

Plate N/A 100% - 450 SCFM 75% - 338 SCFM

0.6 in. H200.5 in. H20

Thermal Effectiveness Ratings at 0” Pressure Differential

Nominal Airflow Sensible Latent Total Net

AirflowNet

SensibleNet

LatentNet

Total

450 HeatingCFM Cooling

73%73%

53%46%

66%56%

450 CFM

73%73%

53%46%

66%56%

338 HeatingCFM Cooling

77%77%

60%52%

71%61%

338CFM

77%77%

60%52%

71%61%

Leakage Ratings

Pressure Differential EATR OACF Purge Angle

or Setting

Test 1 -1 in. H20 1.0% 1.00 N/A

Test 2 0 in. H20 0.0% 1.02 N/A

Test 3 1 in. H20 0.0% 1.05 N/A

AHRI-1060 Certified Performance - Model Number L125-G5

Type Tilt Angle Nominal Airflow Pressure Drop

Plate N/A 100% - 750 SCFM 75% - 563 SCFM

0.65 in. H200.45 in. H20

Thermal Effectiveness Ratings at 0” Pressure Differential

Nominal Airflow Sensible Latent Total Net

AirflowNet

SensibleNet

LatentNet

Total

750 HeatingCFM Cooling

71%71%

52%43%

64%53%

750 CFM

71%71%

52%43%

64%53%

563 HeatingCFM Cooling

75%75%

59%50%

69%59%

563CFM

75%75%

59%50%

69%59%

NOTE: SCFM = Standard Cubic Feet per Minute OACF = Outdoor Air Correction Factor EATR = Exhaust Air Transfer Ratio N/A = Not Applicable

Energy recovery component certified in accordance with AHRI Standard 1060-2005.Actual performance in packaged equipment may vary.

7-8 "IN" = INDOOR

11 WALL TYPE (UNUSED IN PA MODELS):

1-2 MODEL:

21 OPTION 1 (RESERVED): "-" = NONE

22 OPTION 2 (RESERVED): "-" = NONE

24 OPTION 4: PRE-ASSEMBLY

25 UL: "N" = NON-LISTED

MODEL NUMBER

MU

LTIP

LE-C

HO

ICE

OR

O

PTI

ON

AL

FEAT

UR

ES

STANDARDFEATURES

9BASE TYPE (SEE DIAGRAM)(CA) "-" (NONE)(PA) "9" = FORKLIFT BASE 10

3-5QTY OF CORES:

"CA" = CABINET APPLIED"PA" = PANELIZED APPLIED

12-20 UNUSED IN PA, CA MODELS

6 CORE: "J" = G5

23 OPTION 3 (RESERVED): "-" = NONE

"K" = KNOCKDOWN (PA MODELS)"A" = ASSEMBLED (PA MODELS)"-" = NOT APPLICABLE (CA MODELS)

AIRFLOW ORIENTATION (UNUSED IN CA MODELS)

"S" = SINGLE (CA MODELS ONLY)"D" = DOUBLE (CA MODELS ONLY)

"nX" = (n) CORESn = 2, 3, 4 (CA MODELS)n = 6, 8, 9, 12 (PA MODELS)

"1" = OPPOSITE-SIDE ENTRY, CROSS-FLOW"2" = SAME-SIDE ENTRY, CROSS FLOW"3" = OPPOSITE-SIDE ENTRY, PARALLEL-FLOW"4" = SAME-SIDE ENTRY, PARALLEL-FLOW"-" = DEFAULT IN CA MODELS AND IN PA MODELS WITH PRE-ASSEMBLY OPTION "K" (KNOCK-DOWN).

J I N N- - - - - - - --- - -1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

CA & PA MODELS

Model Numbering Guide Not all options are available on every model.

Page 70: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

Mo

del N

um

berin

g G

uid

e

Not

e: N

ot a

ll o

ptio

ns a

re a

vail

able

on

ever

y m

odel

.

J-

--

-

6C

OR

E: "

J" =

G5

11W

ALL

TY

PE

: "S

" = S

ING

LE, "

D" =

DO

UB

LE

12PH

ASE:

"1" =

SIN

GLE

-PH

ASE,

"3" =

TH

REE

-PH

ASE

192122

OP

TIO

N 1

: 24V

TR

AN

S. (

RE

STR

ICTI

ON

S 1

1 &

12)

:

25U

L LI

STI

NG

(S

EE

RE

STR

ICTI

ON

15)

:M

OD

EL

NU

MB

ER

MULTIPLE-CHOICE OR OPTIONAL FEATURESSTANDARD

FEATURES

9B

AS

E T

YP

E (S

EE

RE

STR

ICTI

ON

1)

"V",

"H",

"T" (

IND

OO

R U

NIT

S)

"V",

"H",

"R",

"F",

"C" (

RO

OFT

OP

UN

ITS

)"-

" - D

EFA

ULT

IN H

E45

0

10U

NU

SE

D IN

HE

MO

DE

L

13V

OLT

AG

E: (

SE

E R

ES

TRIC

TIO

NS

2, 3

, 4 &

5)

7-8

IND

OO

R/O

UTD

OO

R

1-5

MO

DE

L

20

16-1

8U

NU

SE

D IN

TH

ES

E M

OD

ELS

15E

A H

OR

SE

PO

WE

R14

FA H

OR

SE

PO

WE

R"H

" = 0

.75

HP

EPA

CT

DIR

EC

T-D

RIV

E (

HE

-1X

ON

LY)

"J" =

1.5

HP

EPA

CT

(HE

-2X

ON

LY)

"K" =

2H

P E

PAC

T (H

E-2

X, H

E-3

X, H

E-4

X O

NLY

)"L

" = 3

HP

EPA

CT

(HE

-3X

, HE

-4X

ON

LY)

"M" =

5H

P E

PAC

T (H

E-3

X, H

E-4

X, H

E-6

X, H

E-8

X O

NLY

)"N

" 7.5

HP

EPA

CT

(HE

-6X

, HE

-8X

ON

LY)

"P" 1

0HP

EPA

CT

(HE

-8X

ON

LY)

"Q" =

(2) 0

.75H

P E

PAC

T D

IRE

CT-

DR

IVE

(H

E-2

X O

NLY

)"-

" = D

EFA

ULT

IN E

V45

0

"IN" =

IND

OO

R, "

RT"

= R

OO

FTO

P

"1" =

115

V, "4

" = 4

60V,

"5" =

208

-230

V,

"6" =

115

/208

-230

V, "7

" = 2

08-2

30/4

60V,

"8

" = 5

75V,

"9" =

277

V

RESTRICTIONS:

1: B

AS

E T

YP

E "C

" NO

T AV

AIL

AB

LE W

ITH

MO

DE

LS

EV

450,

HE

-6X

, HE

-8X

.B

AS

E T

YP

E "T

" AVA

ILA

BLE

ON

LY IN

HE

-6X

, HE

-8X

.

2: V

OLT

AG

E C

OD

ES

"1",

"6" &

"9" A

VAIL

AB

LE W

ITH

P

HA

SE

CO

DE

"1" (

SIN

GLE

-PH

AS

E) O

NLY

.

3: V

OLT

AG

E C

OD

ES

"4",

"7" &

"8" A

VAIL

AB

LE W

ITH

P

HA

SE

CO

DE

"3" (

THR

EE

-PH

AS

E) O

NLY

.

4. V

OLT

AG

E C

OD

E "9

" (27

7V) A

VAIL

AB

LE O

NLY

WIT

H

HO

RS

EP

OW

ER

CO

DE

S "H

", "Q

" OR

EV

450

MO

DE

L.

5: V

OLT

AG

E C

OD

E "8

" (57

5V) N

OT

AVA

ILA

BLE

WIT

H

HO

RS

EP

OW

ER

CO

DE

S "H

", "Q

" OR

WIT

H M

OD

EL

EV

450.

V

OLT

AG

E C

OD

ES

"1" (

115V

), "6

" (11

5/20

8-23

0V),

"7"

(208

-230

/460

V),

"9" (

277V

) NO

T AV

AIL

AB

LE IN

HE

-6X

, H

E-8

X.

VO

LTA

GE

CO

DE

"5" (

208-

230V

) NO

T AV

AIL

AB

LE W

ITH

P

HA

SE

CO

DE

"1" (

SIN

GLE

-PH

AS

E) I

N M

OD

ELS

HE

-6X

&

HE

-8X

.

6: V

OLT

AG

E C

OD

ES

"1" &

"6" A

VAIL

AB

LE O

NLY

WIT

H

FA/E

A H

OR

SE

PO

WE

R C

OD

ES

"H",

'Q" &

"-".

7: U

NIT

CO

NTR

OL

CO

DE

"R" (

INV

ER

TER

RE

AD

Y) N

OT

AVA

ILA

BLE

WIT

H P

HA

SE

CO

DE

"1" (

SIN

GLE

PH

AS

E),

OR

IN M

OD

EL

EV

450.

8: U

NIT

CO

NTR

OL

CO

DE

"D" (

2 C

ON

TAC

TOR

S) N

OT

AVA

ILA

BLE

IN M

OD

EL

EV

450.

9: D

ISC

ON

NE

CT

CO

DE

S "N

" & "F

" AVA

ILA

BLE

ON

LY

WIT

H V

OLT

AG

E C

OD

ES

1, 4

, 5, 8

& 9

.

10: D

ISC

ON

NE

CT

CO

DE

S "N

" & "F

" NO

T AV

AIL

AB

LE

WIT

H U

NIT

CO

NTR

OL

CO

DE

"R" (

INV

ER

TER

RE

AD

Y).

11: T

RA

NS

FOR

ME

R C

OD

E "T

" (TR

40) A

VAIL

AB

LE O

NLY

W

ITH

VO

LTA

GE

CO

DE

S 1

, 4, 5

& 9

.

12: T

RA

NS

FOR

ME

R C

OD

E "T

" (TR

40) N

OT

AVA

ILA

BLE

W

ITH

UN

IT C

ON

TRO

L C

OD

ES

"D" (

2 C

ON

TAC

TOR

S) O

R

"R" (

INV

ER

TER

RE

AD

Y),

EX

CE

PT

IN M

OD

ELS

HE

-6X

&

HE

-8X

.

13: F

ILTE

R M

ON

ITO

RS

NO

T AV

AIL

AB

LE IN

EV

450.

14: S

OM

E U

NIT

S W

ITH

CU

STO

M "X

" CO

DE

NO

T U

L-LI

STE

D.

23O

THE

R O

PTI

ON

S (R

ES

ER

VE

D)

24

UL:

"L" =

LIS

TED

"N

" = N

ON

-LIS

TED

OP

TIO

N 4

: OTH

ER

S

"-" =

NO

NE

"T" =

TR

40 (T

RA

NS

FOR

ME

R W

ITH

ISO

LATI

ON

RE

LAY

)

"-" =

NO

NE

,"W

" = W

HIT

E P

AIN

T, "C

" = C

US

TOM

PA

INT

"X" =

CU

STO

M U

NIT

RE

STR

ICTI

ON

6

12

34

56

78

910

1112

1314

1516

1718

1920

2122

2324

25 UN

IT C

ON

TRO

L (R

ES

TRIC

TIO

NS

7 &

8)

DIS

CO

NN

EC

T (R

ES

TRIC

TIO

NS

9 &

10)

:"N

" = N

ON

-FU

SE

D"F

" = F

US

ED

"-" =

NO

NE

"A" =

(1) 2

4V C

ON

TAC

TOR

"D" =

(2) 2

4V C

ON

TAC

TOR

S"R

" = IN

VE

RTE

R R

EA

DY

(NO

CO

NTA

CTO

R)

OP

TIO

N 2

: FIL

TER

MO

NIT

OR

(RE

STR

ICTI

ON

13)

"-" =

NO

NE

,"F

" = F

ILTE

R M

ON

ITO

R B

OTH

AIR

STR

EA

MS

"EV

450"

, "H

E-1

X",

"HE

-2X

""H

E-3

X",

"HE

-4X

", "H

E-6

X, "

HE

-8X

"

EV/H

E M

OD

ELS

For

Tech

nica

l Sup

port

E-m

ail:

Sup

port

@Re

new

Air

e.co

mTo

Pla

ce a

n O

rder

E-m

ail:

Ren

ewA

ireO

rder

s@Re

new

Air

e.co

m

Page 71: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

Save Energy

Reduce Pollution

Material Efficient

People Friendly

Green

Ample Airflow

Pressure Balanced

Quiet Operation

Energy Efficient

Automatic Control

Ve

n t il a tio n

RenewAire ventilation products will give you cleaner air to breathe - letting you and your family feel better and healthier AND will do so in the most consistent, controlled, safe and energy-efficient manner possible.

For over 30 years, RenewAire has been a pioneer in the use of plate exchangers that simultaneously tranfer heat and humidity between ventilation airstreams in extreme climates. From cool-dry (Point Barrow, Alaska) to hot-humid

(Puerto Rico) climates, RenewAire exceeds customer expectations for effective, reliable ventilation solutions.

ERV manufacturing begins using Mitsubishi “Lossnay” core. 1983

HVI residential unit certification confirms superior heat and humidity transfer. 1996

ARI-1060 commercial product certification of only ERV with 0% cross contamination. 2001

G4 - 4th generation core introduced with enhanced humidity transfer. 2004

Energy Star Qualified with energy use in the lowest 20% of comparable buildings. 2006

Introduction of RD Series dedicated outdoor air system. 2008

First HRV and ERV installations using a variety of plate and wheel technologies.1980

RenewAire model is the first listed by UL-1812 standard for ERV safety.1987

Introduction of first roof-top connected unit (RTC).1998

Introduction of BREEZE® easy to install residential unit.2005

Over 100 school projects shipped in one year.2003

New factory achieves LEED-Silver rating. 120,000th North American unit sold. 2007 sales result in 30,000 tons of CO2 emission reductions!2007

RenewAire Product & Ventilation Commitment

G5 - 5th generation core introduced with enhanced humidity transfer. 2010

Introduction of V-Series Ventilation Exhaust Fans.2009

Page 72: (800) 627-4499 - Cymecyme.com.mx/equipos/recuperacion_energia/solerpalau/catalogo Gra… · • (800) 627-4499 † Fax: (608) 221-2824 4510 Helgesen Drive † Madison, Wisconsin 53718

Residential & Small Commercial5 Models• 50 - 300 CFM• built-in 24 V transformer/relay package•

Commercial Products23 Models• 250 - 7,950 CFM• 1 or 3 phase multi-voltage• 24 volt control•

Applied ProductsCA-Series (cabinet) - 500 - 20,000 CFM• PA-Series (panelized) - 1,500 - Unlimited CFM• (requires blowers & manifolds by others)•

Dedicated Outdoor Air Systems4 Models• 500 - 4400 CFM• integrated VFD for each airstream• coil options including DX, chilled • water, hot water and combinations

Ventilation Exhaust Fans4 Models• 50 - 150 CFM• robust steel housing and duct collar• the most efficient line of exhaust fans • available in North America

This piece was printed using earth-friendly soy ink on 100% post-consumer recycled paper. RenewAire ERVs are proudly manufactured in our LEED-Silver Certified facility using 100% wind generated electricity.

Part # LIT029© RenewAire LLC, 2010

Full Line of Ventilation Products