5600 Series Power Operator Installation and Instruction Manual
Transcript of 5600 Series Power Operator Installation and Instruction Manual
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)1
bull Allen wrench set (inch)bull Flat blade screwdriver (potentiometer amp terminal size)bull Screwdriver (Phillips size 2)bull Tape ruler
bull Power drill bull Center punchbull Wire stripperbull 7 drill 14-20 tap (metal frame install)
Tools required
Use screw pack and hardware provided to mount operator
ETL certified conforms to ANSIUL standard325 for automatic closing doors
WARNING To reduce the risk of injury to person use this operator only with Pedestrian Swing doors
Item No Description
1 Motor (5600M)
2 Cover (5600COV)
3 Control Inverter (5600IN)
4 Power Supply 24VDC (5600PS)
5 Track Assembly (5610-1)
6 316 Replacement Motor Key (5600KEY)
2
6
ASSA ABLOY5
4
3
1
ASSA ABLOY
5600 SeriesPower Operator
Installation and Instruction Manual
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)2
Technical Data
Notes Input connections - torque to 48 inlbs (55nm)Permanent wiring is to be employed as required by local codes
Activation devices push plates access control mats touchless wall switches etc
Maximum wire size is12AWG at terminals HOT and COM (120VAC 60Hz) on ldquoT1rdquo Power Input Terminal14AWG at terminals 1 thru 4 on Accessory Terminal
120VAC 60Hz
6 amps
24 V DC max 11 Amp32-36 (81-91cm)
100-150 lb (45-68 kg)
Input power
Power consumption
Power supply
Door width
Door weightDoor opening angle Pull arm 80deg - 95deg with reveal 0 - 18
(0 - 3 mm)
Hold open time 0-30 seconds (ADA 5 seconds min)
5 ampsCircuit breaker
Interior Doors Only
Door Prep
Fasteners for Framebull 14-20 Machine screws for hollow metal and aluminumbull No 14x2-34 (70mm) long sheet metal screws for wood
Notesbull All dimensions are given in inchesbull Thickness recommended for reinforcements in hollow metal doors and
frames is charted at the left of this pagebull Do not scale drawingbull This template information based upon use of 5 maximum width butt
hinges bull Maximum frame reveal is 4 for this applicationbull Before beginning the installation verify that the door frame is properly
reinforced and is well anchored in the wallbull Unreinforced hollow metal frames and aluminum frames should be
prepared and fitted with 14-20 blind rivet nuts furnished by othersbull Concealed electrical conduit and concealed switch or sensor wires
should be pulled to the frame before proceeding
Hollow Metal Door Frame Reinforcing
FrameMaterial
12 Ga1046(266)
14 Ga0747(190)
16 Ga0598(152)
18 Ga0478(121)
12 Ga1046(266)
10 Ga1343(341)
10 Ga1343(341)
8 Ga1644(418)
18 Ga0478(121)
12 Ga1046(266)
12 Ga1046(266)
10 Ga1343(341)
ReinforcingRecommended Min Required
18(3)
Door
Frame
Templating is based on 18 gap between door and frame
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)3
CLHinge
2-122
Bottom of Frame
1-141
6-5811-38
1615-12
Operator Mounting
WARNINGDO NOT REMOVE
ARM FROM OPERATOR
WARNING
ARM MUST CLEAR TOP OF DOOR
1
Track Mounting3
Left hand door illustrated
bull Using template locate and mount trackbull Track MUST be flush with top of door
Attach Operator2
Attach operator to frame using supplied screws
See page 10 for removable
template
1 Using template locate and prepare holes in the frame
2 Drill 7 and tap 14-20 Machine Screws or Self Drilling Screws (6 places)
1
2
32
SNAP
1
CL Hinge3
CL Screw
1 - Insert end caps2 - Attach screws3 - Snap on track cover
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)4
Determine Hand of Door
2 - ON = Push amp Go OFF = Door Closer Mode
1 - Door Mounting ON = RH OFF = LH
Attach Arm4
5Right Hand Left Hand
Magnets are used to signal the unit at closed and fully open positions
bull With door in the closed position slide Close Position Magnet so it aligns directly with the sensor
bull With door in the open position slide Open Position Magnet so it aligns directly with the sensor
Note Magnets must be adjusted to meet specific application needs Latch and backcheck positions depend on magnet positions
Adjustment of Closed and Open Position6
A
Attach arm to track slider using provided allen wrench
Turn screw counter-clockwise
A
Open PositionMagnet
Close Position Magnet
Sensor
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)5
See wiring diagram examples on pages 7-9
7 Activation Connection
D
C
F24VDC Power
Supply for Powered
Accessories
Terminal Description
HOT
COM Common power lead (Neutral)
Hot power lead (120VAC 60Hz)
Input Wiring Instructions
Grounding8
WARNING
UNIT WILL NOT FUNCTION CORRECTLY WITHOUT PROPER
GROUNDINGGROUND WIRE MUST BE
SECURED TO BACKPLATE UNDER HEAD OF (GREEN) GROUND
SCREW LABELED ldquoGNDrdquo
C
Power Connection9
D
24
23
22
25
HOT
COM
BreakerSwitch
FB
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
B
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)6
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
E
1 Align Close Position Magnet with sensor 2 Turn power on at the Unit OnOff Switch
located on the end cap3 Turn Breaker Switch to Reset (Breaker
Switch shown in step 9) Red LED in breaker should be on and circuit board LEDs should illuminate
Inverter Control Board Adjustments Based on function adjustment desired use
table below to determine which POT is to be adjusted
Required Magnets must be adjusted for specific application
WARNINGELECTRIC SHOCK RISK
(Adjustments made in the shaded area should be performed by
Authorized Factory Personnel)
POT FUNCTIONDESCRIPTION
OBSTR SENS Obstruction Detection on Open CW - IncreaseCCW - Decrease
MDLY Motor Delay on Opening CW - IncreaseCCW - Decrease
P1 Sweep Closing Force (90deg - 20deg) CW - IncreaseCCW - Decrease
HO TM Hold Open Time (5 - 30 Seconds) CW - IncreaseCCW - Decrease
P2 Latch Force (20deg - 0deg) CW - IncreaseCCW - Decrease
HO TQMotor Torque at Hold Open Backcheck Position
CW - IncreaseCCW - Decrease
E
Power-On Procedures10
Control Set-Up11
ADJUSTMENT TABLE
Signage12Affix Caution Labels on both sides of the door Labels should be centered across the width of the door and 50 from the floor
Center
50
Open PositionMagnet
Close Position Magnet
Sensor
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)7
Standard Function with Switches
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
Wall Switch Card Reader Key Switch etcNormally Open Momentary dry contacts
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
Operation
Doors are normally closed
Activating either switch will open both doors Door will close after hold open time delay has elapsed
Door 1
Optional Door 2
Wave to Open Switch Wiring
Operation
Door is normally closed Activating Wave to Open Switch will open the door The door will close after hold open delay elapses
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Wave to Open Switch can be ordered separately or as a kit
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Wave to Open Switch(back side)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)8
Fail Secure Fail Safe Electric Strike Wiring
Operation
Door is normally closed and latched
Activating switch will unlock the electric strike and the door will automatically open Door will close after hold open time delay has elapsed
bull For Fail Secure Strike The door will remain locked during power failure
bull For Fail Safe Strike The door will unlock during power failure
JMP503
NC
NO
Radio Frequency Function Option
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Radio Frequency Feature can be purchased as a separate kit and installed as pictured below
Operation Door is normally closed Activating wireless switch or hand held
wireless transmitter will open the door Door will close after hold open delay elapses
Optional Door 2
Door 1 12
34
5
433MHz Receiver(Mounted on Operator)Wiring for MomentaryHold Open Function
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Jumper SettingsPlace jumper to upper position for normally closed (Fail Safe) operation or to lower position for normally open (Fail Secure) operation
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
RF ReceiverUnit
DC
Ele
ctric
Str
ike
+
-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)9
Fail Safe Electromagnetic Lock 24VDC WiringNotes1 Power input to Door Operator Unit is at ldquoT1rdquo Power
Input Terminal (not shown) 120VAC 60Hz
2 Unitrsquos Relay Rating 30VDC 1A or 125VAC 5A
Operation
Door is normally closed and latched
Activating switch will cut power to mag lock and the door will automatically open Door will close after hold open time delay has elapsed
The door will unlock during power failure
Jumper SettingsPlace jumper to upper position for normally closed operation
JMP503
NC
NO
24VDC Electromagnetic Lock (Fail Safe)
+-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
Notes1 All switches latches and other accessaries should be
connected according to standard wiring instructions 2 Recommend RF kit 573 for use with Executive
Feature
Executive Feature
Operation
Door is normally closed and latched
Activating switch will open the door and the door will stay open until the button is depressed again then the door will close and latch
Jumper SettingsWITH POWER DISCONNECTED Place jumper on pins 1 and 2 to activate the Executive Feature program
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
FF
Normaloperation
Executiveoperation
J502
J502
1 2 3 4
1 2 3 4
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)10
PU
LL
SID
ELe
ft H
and
Doo
r Ill
ustr
ated H
inge
or P
ivot
1-1
4
PU
LL
SID
ER
ight
Han
d D
oor
Illus
trat
ed
1
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
WA
RN
ING
Arm
mus
t cle
ar to
p of
do
or D
o N
ot R
emov
eA
rm F
rom
Ope
rato
r
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2 2
C LH
inge
or P
ivot
1-1
4 11-
18
1-3
8
14
2
1-3
8
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2
C L
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
41-
18
Oslash 7
8
Oslash 7
8
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)2
Technical Data
Notes Input connections - torque to 48 inlbs (55nm)Permanent wiring is to be employed as required by local codes
Activation devices push plates access control mats touchless wall switches etc
Maximum wire size is12AWG at terminals HOT and COM (120VAC 60Hz) on ldquoT1rdquo Power Input Terminal14AWG at terminals 1 thru 4 on Accessory Terminal
120VAC 60Hz
6 amps
24 V DC max 11 Amp32-36 (81-91cm)
100-150 lb (45-68 kg)
Input power
Power consumption
Power supply
Door width
Door weightDoor opening angle Pull arm 80deg - 95deg with reveal 0 - 18
(0 - 3 mm)
Hold open time 0-30 seconds (ADA 5 seconds min)
5 ampsCircuit breaker
Interior Doors Only
Door Prep
Fasteners for Framebull 14-20 Machine screws for hollow metal and aluminumbull No 14x2-34 (70mm) long sheet metal screws for wood
Notesbull All dimensions are given in inchesbull Thickness recommended for reinforcements in hollow metal doors and
frames is charted at the left of this pagebull Do not scale drawingbull This template information based upon use of 5 maximum width butt
hinges bull Maximum frame reveal is 4 for this applicationbull Before beginning the installation verify that the door frame is properly
reinforced and is well anchored in the wallbull Unreinforced hollow metal frames and aluminum frames should be
prepared and fitted with 14-20 blind rivet nuts furnished by othersbull Concealed electrical conduit and concealed switch or sensor wires
should be pulled to the frame before proceeding
Hollow Metal Door Frame Reinforcing
FrameMaterial
12 Ga1046(266)
14 Ga0747(190)
16 Ga0598(152)
18 Ga0478(121)
12 Ga1046(266)
10 Ga1343(341)
10 Ga1343(341)
8 Ga1644(418)
18 Ga0478(121)
12 Ga1046(266)
12 Ga1046(266)
10 Ga1343(341)
ReinforcingRecommended Min Required
18(3)
Door
Frame
Templating is based on 18 gap between door and frame
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)3
CLHinge
2-122
Bottom of Frame
1-141
6-5811-38
1615-12
Operator Mounting
WARNINGDO NOT REMOVE
ARM FROM OPERATOR
WARNING
ARM MUST CLEAR TOP OF DOOR
1
Track Mounting3
Left hand door illustrated
bull Using template locate and mount trackbull Track MUST be flush with top of door
Attach Operator2
Attach operator to frame using supplied screws
See page 10 for removable
template
1 Using template locate and prepare holes in the frame
2 Drill 7 and tap 14-20 Machine Screws or Self Drilling Screws (6 places)
1
2
32
SNAP
1
CL Hinge3
CL Screw
1 - Insert end caps2 - Attach screws3 - Snap on track cover
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)4
Determine Hand of Door
2 - ON = Push amp Go OFF = Door Closer Mode
1 - Door Mounting ON = RH OFF = LH
Attach Arm4
5Right Hand Left Hand
Magnets are used to signal the unit at closed and fully open positions
bull With door in the closed position slide Close Position Magnet so it aligns directly with the sensor
bull With door in the open position slide Open Position Magnet so it aligns directly with the sensor
Note Magnets must be adjusted to meet specific application needs Latch and backcheck positions depend on magnet positions
Adjustment of Closed and Open Position6
A
Attach arm to track slider using provided allen wrench
Turn screw counter-clockwise
A
Open PositionMagnet
Close Position Magnet
Sensor
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)5
See wiring diagram examples on pages 7-9
7 Activation Connection
D
C
F24VDC Power
Supply for Powered
Accessories
Terminal Description
HOT
COM Common power lead (Neutral)
Hot power lead (120VAC 60Hz)
Input Wiring Instructions
Grounding8
WARNING
UNIT WILL NOT FUNCTION CORRECTLY WITHOUT PROPER
GROUNDINGGROUND WIRE MUST BE
SECURED TO BACKPLATE UNDER HEAD OF (GREEN) GROUND
SCREW LABELED ldquoGNDrdquo
C
Power Connection9
D
24
23
22
25
HOT
COM
BreakerSwitch
FB
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
B
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)6
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
E
1 Align Close Position Magnet with sensor 2 Turn power on at the Unit OnOff Switch
located on the end cap3 Turn Breaker Switch to Reset (Breaker
Switch shown in step 9) Red LED in breaker should be on and circuit board LEDs should illuminate
Inverter Control Board Adjustments Based on function adjustment desired use
table below to determine which POT is to be adjusted
Required Magnets must be adjusted for specific application
WARNINGELECTRIC SHOCK RISK
(Adjustments made in the shaded area should be performed by
Authorized Factory Personnel)
POT FUNCTIONDESCRIPTION
OBSTR SENS Obstruction Detection on Open CW - IncreaseCCW - Decrease
MDLY Motor Delay on Opening CW - IncreaseCCW - Decrease
P1 Sweep Closing Force (90deg - 20deg) CW - IncreaseCCW - Decrease
HO TM Hold Open Time (5 - 30 Seconds) CW - IncreaseCCW - Decrease
P2 Latch Force (20deg - 0deg) CW - IncreaseCCW - Decrease
HO TQMotor Torque at Hold Open Backcheck Position
CW - IncreaseCCW - Decrease
E
Power-On Procedures10
Control Set-Up11
ADJUSTMENT TABLE
Signage12Affix Caution Labels on both sides of the door Labels should be centered across the width of the door and 50 from the floor
Center
50
Open PositionMagnet
Close Position Magnet
Sensor
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)7
Standard Function with Switches
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
Wall Switch Card Reader Key Switch etcNormally Open Momentary dry contacts
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
Operation
Doors are normally closed
Activating either switch will open both doors Door will close after hold open time delay has elapsed
Door 1
Optional Door 2
Wave to Open Switch Wiring
Operation
Door is normally closed Activating Wave to Open Switch will open the door The door will close after hold open delay elapses
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Wave to Open Switch can be ordered separately or as a kit
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Wave to Open Switch(back side)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)8
Fail Secure Fail Safe Electric Strike Wiring
Operation
Door is normally closed and latched
Activating switch will unlock the electric strike and the door will automatically open Door will close after hold open time delay has elapsed
bull For Fail Secure Strike The door will remain locked during power failure
bull For Fail Safe Strike The door will unlock during power failure
JMP503
NC
NO
Radio Frequency Function Option
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Radio Frequency Feature can be purchased as a separate kit and installed as pictured below
Operation Door is normally closed Activating wireless switch or hand held
wireless transmitter will open the door Door will close after hold open delay elapses
Optional Door 2
Door 1 12
34
5
433MHz Receiver(Mounted on Operator)Wiring for MomentaryHold Open Function
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Jumper SettingsPlace jumper to upper position for normally closed (Fail Safe) operation or to lower position for normally open (Fail Secure) operation
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
RF ReceiverUnit
DC
Ele
ctric
Str
ike
+
-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)9
Fail Safe Electromagnetic Lock 24VDC WiringNotes1 Power input to Door Operator Unit is at ldquoT1rdquo Power
Input Terminal (not shown) 120VAC 60Hz
2 Unitrsquos Relay Rating 30VDC 1A or 125VAC 5A
Operation
Door is normally closed and latched
Activating switch will cut power to mag lock and the door will automatically open Door will close after hold open time delay has elapsed
The door will unlock during power failure
Jumper SettingsPlace jumper to upper position for normally closed operation
JMP503
NC
NO
24VDC Electromagnetic Lock (Fail Safe)
+-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
Notes1 All switches latches and other accessaries should be
connected according to standard wiring instructions 2 Recommend RF kit 573 for use with Executive
Feature
Executive Feature
Operation
Door is normally closed and latched
Activating switch will open the door and the door will stay open until the button is depressed again then the door will close and latch
Jumper SettingsWITH POWER DISCONNECTED Place jumper on pins 1 and 2 to activate the Executive Feature program
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
FF
Normaloperation
Executiveoperation
J502
J502
1 2 3 4
1 2 3 4
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)10
PU
LL
SID
ELe
ft H
and
Doo
r Ill
ustr
ated H
inge
or P
ivot
1-1
4
PU
LL
SID
ER
ight
Han
d D
oor
Illus
trat
ed
1
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
WA
RN
ING
Arm
mus
t cle
ar to
p of
do
or D
o N
ot R
emov
eA
rm F
rom
Ope
rato
r
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2 2
C LH
inge
or P
ivot
1-1
4 11-
18
1-3
8
14
2
1-3
8
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2
C L
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
41-
18
Oslash 7
8
Oslash 7
8
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)3
CLHinge
2-122
Bottom of Frame
1-141
6-5811-38
1615-12
Operator Mounting
WARNINGDO NOT REMOVE
ARM FROM OPERATOR
WARNING
ARM MUST CLEAR TOP OF DOOR
1
Track Mounting3
Left hand door illustrated
bull Using template locate and mount trackbull Track MUST be flush with top of door
Attach Operator2
Attach operator to frame using supplied screws
See page 10 for removable
template
1 Using template locate and prepare holes in the frame
2 Drill 7 and tap 14-20 Machine Screws or Self Drilling Screws (6 places)
1
2
32
SNAP
1
CL Hinge3
CL Screw
1 - Insert end caps2 - Attach screws3 - Snap on track cover
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)4
Determine Hand of Door
2 - ON = Push amp Go OFF = Door Closer Mode
1 - Door Mounting ON = RH OFF = LH
Attach Arm4
5Right Hand Left Hand
Magnets are used to signal the unit at closed and fully open positions
bull With door in the closed position slide Close Position Magnet so it aligns directly with the sensor
bull With door in the open position slide Open Position Magnet so it aligns directly with the sensor
Note Magnets must be adjusted to meet specific application needs Latch and backcheck positions depend on magnet positions
Adjustment of Closed and Open Position6
A
Attach arm to track slider using provided allen wrench
Turn screw counter-clockwise
A
Open PositionMagnet
Close Position Magnet
Sensor
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)5
See wiring diagram examples on pages 7-9
7 Activation Connection
D
C
F24VDC Power
Supply for Powered
Accessories
Terminal Description
HOT
COM Common power lead (Neutral)
Hot power lead (120VAC 60Hz)
Input Wiring Instructions
Grounding8
WARNING
UNIT WILL NOT FUNCTION CORRECTLY WITHOUT PROPER
GROUNDINGGROUND WIRE MUST BE
SECURED TO BACKPLATE UNDER HEAD OF (GREEN) GROUND
SCREW LABELED ldquoGNDrdquo
C
Power Connection9
D
24
23
22
25
HOT
COM
BreakerSwitch
FB
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
B
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)6
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
E
1 Align Close Position Magnet with sensor 2 Turn power on at the Unit OnOff Switch
located on the end cap3 Turn Breaker Switch to Reset (Breaker
Switch shown in step 9) Red LED in breaker should be on and circuit board LEDs should illuminate
Inverter Control Board Adjustments Based on function adjustment desired use
table below to determine which POT is to be adjusted
Required Magnets must be adjusted for specific application
WARNINGELECTRIC SHOCK RISK
(Adjustments made in the shaded area should be performed by
Authorized Factory Personnel)
POT FUNCTIONDESCRIPTION
OBSTR SENS Obstruction Detection on Open CW - IncreaseCCW - Decrease
MDLY Motor Delay on Opening CW - IncreaseCCW - Decrease
P1 Sweep Closing Force (90deg - 20deg) CW - IncreaseCCW - Decrease
HO TM Hold Open Time (5 - 30 Seconds) CW - IncreaseCCW - Decrease
P2 Latch Force (20deg - 0deg) CW - IncreaseCCW - Decrease
HO TQMotor Torque at Hold Open Backcheck Position
CW - IncreaseCCW - Decrease
E
Power-On Procedures10
Control Set-Up11
ADJUSTMENT TABLE
Signage12Affix Caution Labels on both sides of the door Labels should be centered across the width of the door and 50 from the floor
Center
50
Open PositionMagnet
Close Position Magnet
Sensor
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)7
Standard Function with Switches
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
Wall Switch Card Reader Key Switch etcNormally Open Momentary dry contacts
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
Operation
Doors are normally closed
Activating either switch will open both doors Door will close after hold open time delay has elapsed
Door 1
Optional Door 2
Wave to Open Switch Wiring
Operation
Door is normally closed Activating Wave to Open Switch will open the door The door will close after hold open delay elapses
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Wave to Open Switch can be ordered separately or as a kit
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Wave to Open Switch(back side)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)8
Fail Secure Fail Safe Electric Strike Wiring
Operation
Door is normally closed and latched
Activating switch will unlock the electric strike and the door will automatically open Door will close after hold open time delay has elapsed
bull For Fail Secure Strike The door will remain locked during power failure
bull For Fail Safe Strike The door will unlock during power failure
JMP503
NC
NO
Radio Frequency Function Option
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Radio Frequency Feature can be purchased as a separate kit and installed as pictured below
Operation Door is normally closed Activating wireless switch or hand held
wireless transmitter will open the door Door will close after hold open delay elapses
Optional Door 2
Door 1 12
34
5
433MHz Receiver(Mounted on Operator)Wiring for MomentaryHold Open Function
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Jumper SettingsPlace jumper to upper position for normally closed (Fail Safe) operation or to lower position for normally open (Fail Secure) operation
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
RF ReceiverUnit
DC
Ele
ctric
Str
ike
+
-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)9
Fail Safe Electromagnetic Lock 24VDC WiringNotes1 Power input to Door Operator Unit is at ldquoT1rdquo Power
Input Terminal (not shown) 120VAC 60Hz
2 Unitrsquos Relay Rating 30VDC 1A or 125VAC 5A
Operation
Door is normally closed and latched
Activating switch will cut power to mag lock and the door will automatically open Door will close after hold open time delay has elapsed
The door will unlock during power failure
Jumper SettingsPlace jumper to upper position for normally closed operation
JMP503
NC
NO
24VDC Electromagnetic Lock (Fail Safe)
+-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
Notes1 All switches latches and other accessaries should be
connected according to standard wiring instructions 2 Recommend RF kit 573 for use with Executive
Feature
Executive Feature
Operation
Door is normally closed and latched
Activating switch will open the door and the door will stay open until the button is depressed again then the door will close and latch
Jumper SettingsWITH POWER DISCONNECTED Place jumper on pins 1 and 2 to activate the Executive Feature program
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
FF
Normaloperation
Executiveoperation
J502
J502
1 2 3 4
1 2 3 4
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)10
PU
LL
SID
ELe
ft H
and
Doo
r Ill
ustr
ated H
inge
or P
ivot
1-1
4
PU
LL
SID
ER
ight
Han
d D
oor
Illus
trat
ed
1
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
WA
RN
ING
Arm
mus
t cle
ar to
p of
do
or D
o N
ot R
emov
eA
rm F
rom
Ope
rato
r
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2 2
C LH
inge
or P
ivot
1-1
4 11-
18
1-3
8
14
2
1-3
8
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2
C L
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
41-
18
Oslash 7
8
Oslash 7
8
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)4
Determine Hand of Door
2 - ON = Push amp Go OFF = Door Closer Mode
1 - Door Mounting ON = RH OFF = LH
Attach Arm4
5Right Hand Left Hand
Magnets are used to signal the unit at closed and fully open positions
bull With door in the closed position slide Close Position Magnet so it aligns directly with the sensor
bull With door in the open position slide Open Position Magnet so it aligns directly with the sensor
Note Magnets must be adjusted to meet specific application needs Latch and backcheck positions depend on magnet positions
Adjustment of Closed and Open Position6
A
Attach arm to track slider using provided allen wrench
Turn screw counter-clockwise
A
Open PositionMagnet
Close Position Magnet
Sensor
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)5
See wiring diagram examples on pages 7-9
7 Activation Connection
D
C
F24VDC Power
Supply for Powered
Accessories
Terminal Description
HOT
COM Common power lead (Neutral)
Hot power lead (120VAC 60Hz)
Input Wiring Instructions
Grounding8
WARNING
UNIT WILL NOT FUNCTION CORRECTLY WITHOUT PROPER
GROUNDINGGROUND WIRE MUST BE
SECURED TO BACKPLATE UNDER HEAD OF (GREEN) GROUND
SCREW LABELED ldquoGNDrdquo
C
Power Connection9
D
24
23
22
25
HOT
COM
BreakerSwitch
FB
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
B
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)6
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
E
1 Align Close Position Magnet with sensor 2 Turn power on at the Unit OnOff Switch
located on the end cap3 Turn Breaker Switch to Reset (Breaker
Switch shown in step 9) Red LED in breaker should be on and circuit board LEDs should illuminate
Inverter Control Board Adjustments Based on function adjustment desired use
table below to determine which POT is to be adjusted
Required Magnets must be adjusted for specific application
WARNINGELECTRIC SHOCK RISK
(Adjustments made in the shaded area should be performed by
Authorized Factory Personnel)
POT FUNCTIONDESCRIPTION
OBSTR SENS Obstruction Detection on Open CW - IncreaseCCW - Decrease
MDLY Motor Delay on Opening CW - IncreaseCCW - Decrease
P1 Sweep Closing Force (90deg - 20deg) CW - IncreaseCCW - Decrease
HO TM Hold Open Time (5 - 30 Seconds) CW - IncreaseCCW - Decrease
P2 Latch Force (20deg - 0deg) CW - IncreaseCCW - Decrease
HO TQMotor Torque at Hold Open Backcheck Position
CW - IncreaseCCW - Decrease
E
Power-On Procedures10
Control Set-Up11
ADJUSTMENT TABLE
Signage12Affix Caution Labels on both sides of the door Labels should be centered across the width of the door and 50 from the floor
Center
50
Open PositionMagnet
Close Position Magnet
Sensor
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)7
Standard Function with Switches
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
Wall Switch Card Reader Key Switch etcNormally Open Momentary dry contacts
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
Operation
Doors are normally closed
Activating either switch will open both doors Door will close after hold open time delay has elapsed
Door 1
Optional Door 2
Wave to Open Switch Wiring
Operation
Door is normally closed Activating Wave to Open Switch will open the door The door will close after hold open delay elapses
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Wave to Open Switch can be ordered separately or as a kit
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Wave to Open Switch(back side)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)8
Fail Secure Fail Safe Electric Strike Wiring
Operation
Door is normally closed and latched
Activating switch will unlock the electric strike and the door will automatically open Door will close after hold open time delay has elapsed
bull For Fail Secure Strike The door will remain locked during power failure
bull For Fail Safe Strike The door will unlock during power failure
JMP503
NC
NO
Radio Frequency Function Option
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Radio Frequency Feature can be purchased as a separate kit and installed as pictured below
Operation Door is normally closed Activating wireless switch or hand held
wireless transmitter will open the door Door will close after hold open delay elapses
Optional Door 2
Door 1 12
34
5
433MHz Receiver(Mounted on Operator)Wiring for MomentaryHold Open Function
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Jumper SettingsPlace jumper to upper position for normally closed (Fail Safe) operation or to lower position for normally open (Fail Secure) operation
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
RF ReceiverUnit
DC
Ele
ctric
Str
ike
+
-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)9
Fail Safe Electromagnetic Lock 24VDC WiringNotes1 Power input to Door Operator Unit is at ldquoT1rdquo Power
Input Terminal (not shown) 120VAC 60Hz
2 Unitrsquos Relay Rating 30VDC 1A or 125VAC 5A
Operation
Door is normally closed and latched
Activating switch will cut power to mag lock and the door will automatically open Door will close after hold open time delay has elapsed
The door will unlock during power failure
Jumper SettingsPlace jumper to upper position for normally closed operation
JMP503
NC
NO
24VDC Electromagnetic Lock (Fail Safe)
+-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
Notes1 All switches latches and other accessaries should be
connected according to standard wiring instructions 2 Recommend RF kit 573 for use with Executive
Feature
Executive Feature
Operation
Door is normally closed and latched
Activating switch will open the door and the door will stay open until the button is depressed again then the door will close and latch
Jumper SettingsWITH POWER DISCONNECTED Place jumper on pins 1 and 2 to activate the Executive Feature program
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
FF
Normaloperation
Executiveoperation
J502
J502
1 2 3 4
1 2 3 4
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)10
PU
LL
SID
ELe
ft H
and
Doo
r Ill
ustr
ated H
inge
or P
ivot
1-1
4
PU
LL
SID
ER
ight
Han
d D
oor
Illus
trat
ed
1
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
WA
RN
ING
Arm
mus
t cle
ar to
p of
do
or D
o N
ot R
emov
eA
rm F
rom
Ope
rato
r
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2 2
C LH
inge
or P
ivot
1-1
4 11-
18
1-3
8
14
2
1-3
8
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2
C L
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
41-
18
Oslash 7
8
Oslash 7
8
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)5
See wiring diagram examples on pages 7-9
7 Activation Connection
D
C
F24VDC Power
Supply for Powered
Accessories
Terminal Description
HOT
COM Common power lead (Neutral)
Hot power lead (120VAC 60Hz)
Input Wiring Instructions
Grounding8
WARNING
UNIT WILL NOT FUNCTION CORRECTLY WITHOUT PROPER
GROUNDINGGROUND WIRE MUST BE
SECURED TO BACKPLATE UNDER HEAD OF (GREEN) GROUND
SCREW LABELED ldquoGNDrdquo
C
Power Connection9
D
24
23
22
25
HOT
COM
BreakerSwitch
FB
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
B
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)6
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
E
1 Align Close Position Magnet with sensor 2 Turn power on at the Unit OnOff Switch
located on the end cap3 Turn Breaker Switch to Reset (Breaker
Switch shown in step 9) Red LED in breaker should be on and circuit board LEDs should illuminate
Inverter Control Board Adjustments Based on function adjustment desired use
table below to determine which POT is to be adjusted
Required Magnets must be adjusted for specific application
WARNINGELECTRIC SHOCK RISK
(Adjustments made in the shaded area should be performed by
Authorized Factory Personnel)
POT FUNCTIONDESCRIPTION
OBSTR SENS Obstruction Detection on Open CW - IncreaseCCW - Decrease
MDLY Motor Delay on Opening CW - IncreaseCCW - Decrease
P1 Sweep Closing Force (90deg - 20deg) CW - IncreaseCCW - Decrease
HO TM Hold Open Time (5 - 30 Seconds) CW - IncreaseCCW - Decrease
P2 Latch Force (20deg - 0deg) CW - IncreaseCCW - Decrease
HO TQMotor Torque at Hold Open Backcheck Position
CW - IncreaseCCW - Decrease
E
Power-On Procedures10
Control Set-Up11
ADJUSTMENT TABLE
Signage12Affix Caution Labels on both sides of the door Labels should be centered across the width of the door and 50 from the floor
Center
50
Open PositionMagnet
Close Position Magnet
Sensor
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)7
Standard Function with Switches
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
Wall Switch Card Reader Key Switch etcNormally Open Momentary dry contacts
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
Operation
Doors are normally closed
Activating either switch will open both doors Door will close after hold open time delay has elapsed
Door 1
Optional Door 2
Wave to Open Switch Wiring
Operation
Door is normally closed Activating Wave to Open Switch will open the door The door will close after hold open delay elapses
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Wave to Open Switch can be ordered separately or as a kit
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Wave to Open Switch(back side)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)8
Fail Secure Fail Safe Electric Strike Wiring
Operation
Door is normally closed and latched
Activating switch will unlock the electric strike and the door will automatically open Door will close after hold open time delay has elapsed
bull For Fail Secure Strike The door will remain locked during power failure
bull For Fail Safe Strike The door will unlock during power failure
JMP503
NC
NO
Radio Frequency Function Option
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Radio Frequency Feature can be purchased as a separate kit and installed as pictured below
Operation Door is normally closed Activating wireless switch or hand held
wireless transmitter will open the door Door will close after hold open delay elapses
Optional Door 2
Door 1 12
34
5
433MHz Receiver(Mounted on Operator)Wiring for MomentaryHold Open Function
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Jumper SettingsPlace jumper to upper position for normally closed (Fail Safe) operation or to lower position for normally open (Fail Secure) operation
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
RF ReceiverUnit
DC
Ele
ctric
Str
ike
+
-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)9
Fail Safe Electromagnetic Lock 24VDC WiringNotes1 Power input to Door Operator Unit is at ldquoT1rdquo Power
Input Terminal (not shown) 120VAC 60Hz
2 Unitrsquos Relay Rating 30VDC 1A or 125VAC 5A
Operation
Door is normally closed and latched
Activating switch will cut power to mag lock and the door will automatically open Door will close after hold open time delay has elapsed
The door will unlock during power failure
Jumper SettingsPlace jumper to upper position for normally closed operation
JMP503
NC
NO
24VDC Electromagnetic Lock (Fail Safe)
+-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
Notes1 All switches latches and other accessaries should be
connected according to standard wiring instructions 2 Recommend RF kit 573 for use with Executive
Feature
Executive Feature
Operation
Door is normally closed and latched
Activating switch will open the door and the door will stay open until the button is depressed again then the door will close and latch
Jumper SettingsWITH POWER DISCONNECTED Place jumper on pins 1 and 2 to activate the Executive Feature program
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
FF
Normaloperation
Executiveoperation
J502
J502
1 2 3 4
1 2 3 4
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)10
PU
LL
SID
ELe
ft H
and
Doo
r Ill
ustr
ated H
inge
or P
ivot
1-1
4
PU
LL
SID
ER
ight
Han
d D
oor
Illus
trat
ed
1
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
WA
RN
ING
Arm
mus
t cle
ar to
p of
do
or D
o N
ot R
emov
eA
rm F
rom
Ope
rato
r
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2 2
C LH
inge
or P
ivot
1-1
4 11-
18
1-3
8
14
2
1-3
8
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2
C L
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
41-
18
Oslash 7
8
Oslash 7
8
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)6
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
E
1 Align Close Position Magnet with sensor 2 Turn power on at the Unit OnOff Switch
located on the end cap3 Turn Breaker Switch to Reset (Breaker
Switch shown in step 9) Red LED in breaker should be on and circuit board LEDs should illuminate
Inverter Control Board Adjustments Based on function adjustment desired use
table below to determine which POT is to be adjusted
Required Magnets must be adjusted for specific application
WARNINGELECTRIC SHOCK RISK
(Adjustments made in the shaded area should be performed by
Authorized Factory Personnel)
POT FUNCTIONDESCRIPTION
OBSTR SENS Obstruction Detection on Open CW - IncreaseCCW - Decrease
MDLY Motor Delay on Opening CW - IncreaseCCW - Decrease
P1 Sweep Closing Force (90deg - 20deg) CW - IncreaseCCW - Decrease
HO TM Hold Open Time (5 - 30 Seconds) CW - IncreaseCCW - Decrease
P2 Latch Force (20deg - 0deg) CW - IncreaseCCW - Decrease
HO TQMotor Torque at Hold Open Backcheck Position
CW - IncreaseCCW - Decrease
E
Power-On Procedures10
Control Set-Up11
ADJUSTMENT TABLE
Signage12Affix Caution Labels on both sides of the door Labels should be centered across the width of the door and 50 from the floor
Center
50
Open PositionMagnet
Close Position Magnet
Sensor
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)7
Standard Function with Switches
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
Wall Switch Card Reader Key Switch etcNormally Open Momentary dry contacts
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
Operation
Doors are normally closed
Activating either switch will open both doors Door will close after hold open time delay has elapsed
Door 1
Optional Door 2
Wave to Open Switch Wiring
Operation
Door is normally closed Activating Wave to Open Switch will open the door The door will close after hold open delay elapses
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Wave to Open Switch can be ordered separately or as a kit
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Wave to Open Switch(back side)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)8
Fail Secure Fail Safe Electric Strike Wiring
Operation
Door is normally closed and latched
Activating switch will unlock the electric strike and the door will automatically open Door will close after hold open time delay has elapsed
bull For Fail Secure Strike The door will remain locked during power failure
bull For Fail Safe Strike The door will unlock during power failure
JMP503
NC
NO
Radio Frequency Function Option
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Radio Frequency Feature can be purchased as a separate kit and installed as pictured below
Operation Door is normally closed Activating wireless switch or hand held
wireless transmitter will open the door Door will close after hold open delay elapses
Optional Door 2
Door 1 12
34
5
433MHz Receiver(Mounted on Operator)Wiring for MomentaryHold Open Function
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Jumper SettingsPlace jumper to upper position for normally closed (Fail Safe) operation or to lower position for normally open (Fail Secure) operation
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
RF ReceiverUnit
DC
Ele
ctric
Str
ike
+
-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)9
Fail Safe Electromagnetic Lock 24VDC WiringNotes1 Power input to Door Operator Unit is at ldquoT1rdquo Power
Input Terminal (not shown) 120VAC 60Hz
2 Unitrsquos Relay Rating 30VDC 1A or 125VAC 5A
Operation
Door is normally closed and latched
Activating switch will cut power to mag lock and the door will automatically open Door will close after hold open time delay has elapsed
The door will unlock during power failure
Jumper SettingsPlace jumper to upper position for normally closed operation
JMP503
NC
NO
24VDC Electromagnetic Lock (Fail Safe)
+-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
Notes1 All switches latches and other accessaries should be
connected according to standard wiring instructions 2 Recommend RF kit 573 for use with Executive
Feature
Executive Feature
Operation
Door is normally closed and latched
Activating switch will open the door and the door will stay open until the button is depressed again then the door will close and latch
Jumper SettingsWITH POWER DISCONNECTED Place jumper on pins 1 and 2 to activate the Executive Feature program
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
FF
Normaloperation
Executiveoperation
J502
J502
1 2 3 4
1 2 3 4
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)10
PU
LL
SID
ELe
ft H
and
Doo
r Ill
ustr
ated H
inge
or P
ivot
1-1
4
PU
LL
SID
ER
ight
Han
d D
oor
Illus
trat
ed
1
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
WA
RN
ING
Arm
mus
t cle
ar to
p of
do
or D
o N
ot R
emov
eA
rm F
rom
Ope
rato
r
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2 2
C LH
inge
or P
ivot
1-1
4 11-
18
1-3
8
14
2
1-3
8
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2
C L
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
41-
18
Oslash 7
8
Oslash 7
8
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)7
Standard Function with Switches
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
Wall Switch Card Reader Key Switch etcNormally Open Momentary dry contacts
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
Operation
Doors are normally closed
Activating either switch will open both doors Door will close after hold open time delay has elapsed
Door 1
Optional Door 2
Wave to Open Switch Wiring
Operation
Door is normally closed Activating Wave to Open Switch will open the door The door will close after hold open delay elapses
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Wave to Open Switch can be ordered separately or as a kit
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Wave to Open Switch(back side)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)8
Fail Secure Fail Safe Electric Strike Wiring
Operation
Door is normally closed and latched
Activating switch will unlock the electric strike and the door will automatically open Door will close after hold open time delay has elapsed
bull For Fail Secure Strike The door will remain locked during power failure
bull For Fail Safe Strike The door will unlock during power failure
JMP503
NC
NO
Radio Frequency Function Option
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Radio Frequency Feature can be purchased as a separate kit and installed as pictured below
Operation Door is normally closed Activating wireless switch or hand held
wireless transmitter will open the door Door will close after hold open delay elapses
Optional Door 2
Door 1 12
34
5
433MHz Receiver(Mounted on Operator)Wiring for MomentaryHold Open Function
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Jumper SettingsPlace jumper to upper position for normally closed (Fail Safe) operation or to lower position for normally open (Fail Secure) operation
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
RF ReceiverUnit
DC
Ele
ctric
Str
ike
+
-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)9
Fail Safe Electromagnetic Lock 24VDC WiringNotes1 Power input to Door Operator Unit is at ldquoT1rdquo Power
Input Terminal (not shown) 120VAC 60Hz
2 Unitrsquos Relay Rating 30VDC 1A or 125VAC 5A
Operation
Door is normally closed and latched
Activating switch will cut power to mag lock and the door will automatically open Door will close after hold open time delay has elapsed
The door will unlock during power failure
Jumper SettingsPlace jumper to upper position for normally closed operation
JMP503
NC
NO
24VDC Electromagnetic Lock (Fail Safe)
+-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
Notes1 All switches latches and other accessaries should be
connected according to standard wiring instructions 2 Recommend RF kit 573 for use with Executive
Feature
Executive Feature
Operation
Door is normally closed and latched
Activating switch will open the door and the door will stay open until the button is depressed again then the door will close and latch
Jumper SettingsWITH POWER DISCONNECTED Place jumper on pins 1 and 2 to activate the Executive Feature program
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
FF
Normaloperation
Executiveoperation
J502
J502
1 2 3 4
1 2 3 4
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)10
PU
LL
SID
ELe
ft H
and
Doo
r Ill
ustr
ated H
inge
or P
ivot
1-1
4
PU
LL
SID
ER
ight
Han
d D
oor
Illus
trat
ed
1
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
WA
RN
ING
Arm
mus
t cle
ar to
p of
do
or D
o N
ot R
emov
eA
rm F
rom
Ope
rato
r
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2 2
C LH
inge
or P
ivot
1-1
4 11-
18
1-3
8
14
2
1-3
8
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2
C L
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
41-
18
Oslash 7
8
Oslash 7
8
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)8
Fail Secure Fail Safe Electric Strike Wiring
Operation
Door is normally closed and latched
Activating switch will unlock the electric strike and the door will automatically open Door will close after hold open time delay has elapsed
bull For Fail Secure Strike The door will remain locked during power failure
bull For Fail Safe Strike The door will unlock during power failure
JMP503
NC
NO
Radio Frequency Function Option
Notes1 Power input to Door Operator Unit is at
ldquoT1rdquo Power Input Terminal (not shown) 120VAC 60Hz
2 Radio Frequency Feature can be purchased as a separate kit and installed as pictured below
Operation Door is normally closed Activating wireless switch or hand held
wireless transmitter will open the door Door will close after hold open delay elapses
Optional Door 2
Door 1 12
34
5
433MHz Receiver(Mounted on Operator)Wiring for MomentaryHold Open Function
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Jumper SettingsPlace jumper to upper position for normally closed (Fail Safe) operation or to lower position for normally open (Fail Secure) operation
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
RF ReceiverUnit
DC
Ele
ctric
Str
ike
+
-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)9
Fail Safe Electromagnetic Lock 24VDC WiringNotes1 Power input to Door Operator Unit is at ldquoT1rdquo Power
Input Terminal (not shown) 120VAC 60Hz
2 Unitrsquos Relay Rating 30VDC 1A or 125VAC 5A
Operation
Door is normally closed and latched
Activating switch will cut power to mag lock and the door will automatically open Door will close after hold open time delay has elapsed
The door will unlock during power failure
Jumper SettingsPlace jumper to upper position for normally closed operation
JMP503
NC
NO
24VDC Electromagnetic Lock (Fail Safe)
+-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
Notes1 All switches latches and other accessaries should be
connected according to standard wiring instructions 2 Recommend RF kit 573 for use with Executive
Feature
Executive Feature
Operation
Door is normally closed and latched
Activating switch will open the door and the door will stay open until the button is depressed again then the door will close and latch
Jumper SettingsWITH POWER DISCONNECTED Place jumper on pins 1 and 2 to activate the Executive Feature program
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
FF
Normaloperation
Executiveoperation
J502
J502
1 2 3 4
1 2 3 4
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)10
PU
LL
SID
ELe
ft H
and
Doo
r Ill
ustr
ated H
inge
or P
ivot
1-1
4
PU
LL
SID
ER
ight
Han
d D
oor
Illus
trat
ed
1
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
WA
RN
ING
Arm
mus
t cle
ar to
p of
do
or D
o N
ot R
emov
eA
rm F
rom
Ope
rato
r
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2 2
C LH
inge
or P
ivot
1-1
4 11-
18
1-3
8
14
2
1-3
8
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2
C L
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
41-
18
Oslash 7
8
Oslash 7
8
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)9
Fail Safe Electromagnetic Lock 24VDC WiringNotes1 Power input to Door Operator Unit is at ldquoT1rdquo Power
Input Terminal (not shown) 120VAC 60Hz
2 Unitrsquos Relay Rating 30VDC 1A or 125VAC 5A
Operation
Door is normally closed and latched
Activating switch will cut power to mag lock and the door will automatically open Door will close after hold open time delay has elapsed
The door will unlock during power failure
Jumper SettingsPlace jumper to upper position for normally closed operation
JMP503
NC
NO
24VDC Electromagnetic Lock (Fail Safe)
+-
Wall Switch Card ReaderKey Switch etcNormally Open Momentary dry contacts
1
2
3
4
5
6
Signal input
Signal common
Relay output (K2)
Relay output (K1)
24 VDC (+)
24 VDC (-)
3-5 Jumper wire 22ga or larger
copper wire only (not provided)
Notes1 All switches latches and other accessaries should be
connected according to standard wiring instructions 2 Recommend RF kit 573 for use with Executive
Feature
Executive Feature
Operation
Door is normally closed and latched
Activating switch will open the door and the door will stay open until the button is depressed again then the door will close and latch
Jumper SettingsWITH POWER DISCONNECTED Place jumper on pins 1 and 2 to activate the Executive Feature program
L2115Y
L1115230VAC IN
MOTOR OUT
L2230Y
U
V
W
STATUS LEDS
PUSH PULLSW501
ON
HO TQHO TM
OBSTRSENS
P1
MDLYP2
12
16COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
FF
Normaloperation
Executiveoperation
J502
J502
1 2 3 4
1 2 3 4
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)10
PU
LL
SID
ELe
ft H
and
Doo
r Ill
ustr
ated H
inge
or P
ivot
1-1
4
PU
LL
SID
ER
ight
Han
d D
oor
Illus
trat
ed
1
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
WA
RN
ING
Arm
mus
t cle
ar to
p of
do
or D
o N
ot R
emov
eA
rm F
rom
Ope
rato
r
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2 2
C LH
inge
or P
ivot
1-1
4 11-
18
1-3
8
14
2
1-3
8
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2
C L
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
41-
18
Oslash 7
8
Oslash 7
8
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)10
PU
LL
SID
ELe
ft H
and
Doo
r Ill
ustr
ated H
inge
or P
ivot
1-1
4
PU
LL
SID
ER
ight
Han
d D
oor
Illus
trat
ed
1
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
WA
RN
ING
Arm
mus
t cle
ar to
p of
do
or D
o N
ot R
emov
eA
rm F
rom
Ope
rato
r
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2 2
C LH
inge
or P
ivot
1-1
4 11-
18
1-3
8
14
2
1-3
8
18
D
oor
Fram
e
14-
20 M
achi
ne S
crew
s or
S
elf D
rillin
g S
crew
s (6
Pla
ces)
19
6-5
8
3
4-1
81
24-
34
2-1
2
C L
CR
ITIC
AL
Req
uire
d fo
r pr
oper
inst
alla
tion
41-
18
Oslash 7
8
Oslash 7
8
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)11
Troubleshooting
Fault Possible Reasons Why RemediesExplanations
The door does not open
- the motor does not start
Control switch is set to OFF position
Electrical power is missing
Activation unit does not function
Circuit breaker is set to OFF position Reset the circuit breaker to the ON position
Jump activation input to verify
Check the electrical power switch
Change the setting of the ONOFF switch
- the motor continues to run
Motor is driving in wrong direction
Something jammed beneath the door
Arm has come loose
Flip Door Mounting Dip Switch to other direction
Remove object
Re-install arm and key
The door does not close
Closing power set too low
Arm has come loose
The door is binding or obstructed
Control switch is set to OFF position
Re-install arm and key
Inspect hinges and frame for wear or obstruction
Change the setting of the ONOFF switch
Adjust P1 or P2 according to instructions on pg 8
Maintenance (Service by Authorized Personnel Only)Disconnect power before servicingFrequency of maintenance will depend on factors such as traffic climate etc To make sure your operator is working correctly you should periodically check wire connections tightness of arm connection and screws and wear and tear on hingespivots No serviceable user parts
The door opens and stays open when firstenergized
SW501 is set incorrectly Change the switch setting to the correct handing See instructions on page 4
The electric strike orelectromagnetic lockdoes not work
JMP503 is set incorrectly
Loose or shorted wire to strike or lock
See instructions on page 8 or 9
Inspect wires running from unit to latch device
Provide power to strike or electromagnetic lock fromanother source
Power from unit insufficient for strikeor electromagnetic lock
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-
Copyright copy 2013 2014 Yale Security Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Yale Security Inc is prohibited
ASSA ABLOY
80-9356-0001-020 (02-14)12
For assistance contact Norton Technical Product Support at 877-974-2255
3000 Highway 74 East bull Monroe NC 28112Tel (877)- bull Fax (800)-338-0965974-2255
wwwnor tondoorcontrolscom
ASSA ABLOY
WARNING Make sure that (120V 60Hz) input power is turned off at facilityrsquos main circuit breaker before
General Information
proceeding with installation Do not remove arm for installation
Operation
Your Low Energy Operator can be configured in three variations to meet the standards 1 Push plates Wave-to-open switches etc are available to activate the operator 2 Push amp Go can be enabled In this mode your door is pushed (or pulled) 5deg manually and then
automatically opens to full open position 3 Door can be used as a manual door (Door Closer Mode) The door will work and act like a
standard door closer with power when pushed or pulled open manually Push plates still active If desired overhead presence devices can be provided for an extra level of protection Consult local authority
having jurisdiction These are not required by current ANSIBHMA A15619 standards
Opening
When an opening signal is received by the control unit the door opens to the fully open position The open position is held by the motor If the door is obstructed while opening the door will stop the operator will sense obstruction and the door will close
Note Door must be visible by person operating activation switch(es) Auxiliary door stop (by others) required
Closing
When the hold open time has elapsed the operator will close the door automatically using the motor The door will slow to low speed at latch before it reaches the fully closed position The door is kept closed by low power If the door is obstructed while closing the door will stop the operator will sense obstruction stop and stall If obstructed more than two minutes the unit will turn off To reset manually close the door cycle power and turn switch on Activate push plates to test operation
- Page 1
- Page 2
- Page 3
- Page 4
- Page 5
- Page 6
- Page 7
- Page 8
- Page 9
- Page 10
- Page 11
- Page 12
-