54 51 58 54 52 Test Result (dB) Volume (m3) Volume (m3 ... · Sound Insulation Testing Report This...

7
Sound Insulation Testing Report ATTMA Job No: 5319 Historical Site* (if ticked) Job Ref (optional): 14524A * As defined in Approved Document E - 'Requirements' Tested Site Customer Testing Accreditation Testing Organisation Name AB1 DEVELOPMENTS LTD Address Latchmore House ATTMA Membership No. 9004 Name Airtight & Noisecheck Ltd Address The Plestor 99-101 London Road Address The Old Laundry UKAS No (if accredited) Selborne Cowplain Bridge Street Alton Hampshire Southwick Reporting Standard England Hampshire Hants Approved Document E (2003) including 2004, 2010, 2013, and 2015 Amendments Postcode GU34 3JQ Postcode PO8 8XJ Postcode P017 6DZ Testing Summary Test No Test Date Test Engineer Building Type Building Purpose Test Meter Type Serial Number Source Room Receiver Room Volume (m3) Volume (m3) Test Result (dB) Test Criteria* (dB) Pass/Fail 11077 10/08/2018 Material Change of Use NORSONIC NOR140 1ST FLOOR FLAT 7 Living Room 1 49 52 64 PASS Impact (Floor) Mark Witcher Dwelling-House/Flat 1407126 GROUND FLOOR FLAT 1 Living Room 1 51 11078 10/08/2018 Material Change of Use NORSONIC NOR140 GROUND FLOOR FLAT 1 Living Room 1 51 54 43 PASS Airborne (Floor) Mark Witcher Dwelling-House/Flat 1407126 1ST FLOOR FLAT 7 Living Room 1 49 11079 10/08/2018 Material Change of Use NORSONIC NOR140 1ST FLOOR FLAT 7 Living Room 1 49 58 43 PASS Airborne (Wall) Mark Witcher Dwelling-House/Flat 1407126 1ST FLOOR FLAT 8 Living Room 1 49 11080 10/08/2018 Material Change of Use NORSONIC NOR140 2ND FLOOR FLAT 10 Living Room 1 83 51 64 PASS Impact (Floor) Mark Witcher Dwelling-House/Flat 1407126 1ST FLOOR FLAT 7 Living Room 1 49 11081 10/08/2018 Material Change of Use NORSONIC NOR140 1ST FLOOR FLAT 7 Living Room 1 49 54 43 PASS Airborne (Floor) Mark Witcher Dwelling-House/Flat 1407126 2ND FLOOR FLAT 10 Living Room 1 83 Report Created 10/08/2018 14:52:37 *Minimum criteria for Airborne Tests / Maximum criteria for Impact Tests Page 1 of 2

Transcript of 54 51 58 54 52 Test Result (dB) Volume (m3) Volume (m3 ... · Sound Insulation Testing Report This...

Page 1: 54 51 58 54 52 Test Result (dB) Volume (m3) Volume (m3 ... · Sound Insulation Testing Report This report has been prepared in accordance with the requirements of the reporting standard

Sou

nd

Insu

lati

on

Tes

tin

g R

epo

rt

ATT

MA

Jo

b N

o:

53

19

His

tori

cal S

ite

* (i

f ti

cke

d)

Job

Ref

(o

pti

on

al):

14

52

4A

* A

s d

efin

ed in

Ap

pro

ved

Do

cum

ent

E -

'Req

uir

emen

ts'

Test

ed

Sit

eC

ust

om

er

Test

ing

Acc

red

itat

ion

Test

ing

Org

anis

atio

n

Nam

eA

B1

DEV

ELO

PM

ENTS

LTD

Ad

dre

ssLa

tch

mo

re H

ou

seA

TTM

A M

em

be

rsh

ip N

o.

90

04

Nam

eA

irti

ght

& N

ois

ech

eck

Ltd

Ad

dre

ssTh

e P

lest

or

99

-10

1 L

on

do

n R

oad

Ad

dre

ssTh

e O

ld L

aun

dry

UK

AS

No

(if

acc

red

ite

d)

Selb

orn

eC

ow

pla

inB

rid

ge S

tree

t

Alt

on

Ham

psh

ire

Sou

thw

ick

Re

po

rtin

g St

and

ard

Engl

and

Ham

psh

ire

Han

tsA

pp

rove

d D

ocu

men

t E

(20

03

) in

clu

din

g2

00

4, 2

01

0, 2

01

3, a

nd

20

15

Am

end

men

ts

Po

stco

de

GU

34

3JQ

Po

stco

de

PO

8 8

XJ

Po

stco

de

P0

17

6D

Z

Test

ing

Su

mm

ary

Test

No

Test

Dat

eTe

st E

ngi

ne

er

Bu

ildin

g Ty

pe

Bu

ildin

g P

urp

ose

Test

Me

ter

Typ

eSe

rial

Nu

mb

er

Sou

rce

Ro

om

Re

ceiv

er

Ro

om

Vo

lum

e (

m3

)V

olu

me

(m

3)

Test

Re

sult

(d

B)

Test

Cri

teri

a* (

dB

)P

ass/

Fail

11

07

71

0/0

8/2

01

8M

ater

ial C

han

ge o

f U

seN

OR

SON

IC N

OR

14

01

ST F

LOO

R F

LAT

7 L

ivin

gR

oo

m 1

49

52

64

PA

SS

Imp

act

(Flo

or)

Mar

k W

itch

erD

wel

ling-

Ho

use

/Fla

t1

40

71

26

GR

OU

ND

FLO

OR

FLA

T 1

Livi

ng

Ro

om

15

1

11

07

81

0/0

8/2

01

8M

ater

ial C

han

ge o

f U

seN

OR

SON

IC N

OR

14

0G

RO

UN

D F

LOO

R F

LAT

1Li

vin

g R

oo

m 1

51

54

43

PA

SS

Air

bo

rne

(Flo

or)

Mar

k W

itch

erD

wel

ling-

Ho

use

/Fla

t1

40

71

26

1ST

FLO

OR

FLA

T 7

Liv

ing

Ro

om

14

9

11

07

91

0/0

8/2

01

8M

ater

ial C

han

ge o

f U

seN

OR

SON

IC N

OR

14

01

ST F

LOO

R F

LAT

7 L

ivin

gR

oo

m 1

49

58

43

PA

SS

Air

bo

rne

(Wal

l)M

ark

Wit

cher

Dw

ellin

g-H

ou

se/F

lat

14

07

12

61

ST F

LOO

R F

LAT

8 L

ivin

gR

oo

m 1

49

11

08

01

0/0

8/2

01

8M

ater

ial C

han

ge o

f U

seN

OR

SON

IC N

OR

14

02

ND

FLO

OR

FLA

T 1

0 L

ivin

gR

oo

m 1

83

51

64

PA

SS

Imp

act

(Flo

or)

Mar

k W

itch

erD

wel

ling-

Ho

use

/Fla

t1

40

71

26

1ST

FLO

OR

FLA

T 7

Liv

ing

Ro

om

14

9

11

08

11

0/0

8/2

01

8M

ater

ial C

han

ge o

f U

seN

OR

SON

IC N

OR

14

01

ST F

LOO

R F

LAT

7 L

ivin

gR

oo

m 1

49

54

43

PA

SS

Air

bo

rne

(Flo

or)

Mar

k W

itch

erD

wel

ling-

Ho

use

/Fla

t1

40

71

26

2N

D F

LOO

R F

LAT

10

Liv

ing

Ro

om

18

3

Rep

ort

Cre

ated

10

/08

/20

18

14

:52

:37

*Min

imu

m c

rite

ria

for

Air

bo

rne

Test

s /

Max

imu

m c

rite

ria

for

Imp

act

Test

sP

age

1 o

f 2

Page 2: 54 51 58 54 52 Test Result (dB) Volume (m3) Volume (m3 ... · Sound Insulation Testing Report This report has been prepared in accordance with the requirements of the reporting standard

Sou

nd

Insu

lati

on

Tes

tin

g R

epo

rt

This

rep

ort

has

bee

np

rep

ared

inac

cord

ance

wit

hth

ere

qu

irem

ents

of

the

rep

ort

ing

stan

dar

d(s

tate

dab

ove

).A

llte

sts

wer

eco

nd

uct

edo

nth

eTe

stD

ate

ind

icat

edan

dar

eca

lcu

late

dfr

om

fiel

dm

easu

rem

ents

take

no

nth

atd

ate.

The

test

ing

met

ho

du

sed

and

the

sam

plin

gst

rate

gyad

op

ted

for

thes

ete

sts

isse

to

ut

inre

po

rtin

gst

and

ard

.If

any

dev

iati

on

fro

mth

ete

stin

gm

eth

od

was

nec

essa

ry,

det

ails

of

the

dev

iati

on

are

ind

icat

edo

nea

chin

div

idu

alte

stce

rtif

icat

e(a

pp

end

edto

this

rep

ort

).Te

stre

sult

sfo

rea

chte

star

eau

tho

rise

db

yth

eTe

stin

gEn

gin

eer

ind

icat

edab

ove

,w

ho

has

bee

nap

pro

ved

tod

oso

un

der

the

rule

so

fth

eTe

stin

gSc

hem

e.Ea

chTe

stEn

gin

eer

wo

rks

wit

hin

aTe

stin

gO

rgan

isat

ion

accr

edit

edto

op

erat

eth

eTe

stin

gSc

hem

e.Th

ere

po

rth

asb

een

pre

par

edfo

r,an

dis

for

the

sole

use

of,

the

'Cu

sto

mer

'in

dic

ated

abo

ve.

Itm

ayn

ot

be

relie

du

po

nb

yan

yth

ird

par

tyex

cep

tb

ya

loca

lau

tho

rity

for

the

inte

nd

edp

urp

ose

of

dem

on

stra

tin

gco

mp

lian

cew

ith

req

uir

edb

uild

ing

con

tro

lst

and

ard

s.Th

ere

po

rtm

ayn

ot

be

pre

sen

ted

oth

erth

anin

full

elec

tro

nic

or

pri

nte

dfo

rm,

wit

ho

ut

the

wri

tten

per

mis

sio

no

fth

eTe

stin

gO

rgan

isat

ion

.N

ore

spo

nsi

bili

tyis

acce

pte

dto

any

thir

dp

arty

and

no

liab

ility

isac

cep

ted

ou

tsid

eth

esc

op

eo

fth

isre

po

rt.

Rep

ort

Cre

ated

10

/08

/20

18

14

:52

:37

*Min

imu

m c

rite

ria

for

Air

bo

rne

Test

s /

Max

imu

m c

rite

ria

for

Imp

act

Test

sP

age

2 o

f 2

Page 3: 54 51 58 54 52 Test Result (dB) Volume (m3) Volume (m3 ... · Sound Insulation Testing Report This report has been prepared in accordance with the requirements of the reporting standard

Airtight & NoisechecTesting Org. Name:11077 9004ATTMA Membership No:Test No:

Registered Sound Insulation Test CertificateTest Job Ref: 5319

GU34 3JQ

AB1 DEVELOPMENTS Customer

Address The Plestor

Selborne

Alton

Hampshire

Postcode

Job Address

99-101 London Road

Cowplain

Hampshire

England

PO8 8XJ

Latchmore House

Postcode

Test Type Impact (Floor)

10/08/2018Test Date

Tester Mark Witcher

Site Type

Site Build

Material Change of Use

Dwelling-House/Flat

Source Room: Partition: Receiver Room:

Description 1ST FLOOR FLAT 7 Living Room 1 GROUND FLOOR FLAT 1 Living Roo

Volume / Area 49.0 m3 21.1 m2 51.0 m3

Frequency(Hz)

DnT1/3 Octave

(dB)

HighBGnd

50 Hz* 65.6

63 Hz* 65.0

80 Hz* 54.0

100 Hz 63.3

125 Hz 63.3

160 Hz 61.9

200 Hz 59.4

250 Hz 53.4

315 Hz 45.7

400 Hz 40.7

500 Hz 38.2

630 Hz 32.8

800 Hz 31.2 X

1 KHz 30.8 X

1.25 KHz 29.1 X

1.6 KHz 26.2 X

2 KHz 23.0 X

2.5 KHz 20.5 X

3.15 KHz 18.2 X

4 KHz* 18.7 X

5 KHz* 16.8 X

Evaluation based on field measurement usingresults obtained by an engineering method

*Outside scope of accreditation Above graph shows frequency range according to the curve of reference values within ISO 717-2

PASSLnT,w(CI) [dB]: 52 (1) dB

Maximum Pass Level [dB]: 64 dBAdverse Aggregated Deviations [dB]: 31.9 dB

The test reported on this certificate was carried out in accordance with an approved testing procedure. If it was necessary to deviate fromthis procedure in any way, these deviations are described here:

Approved Document E (2003) including 2004, 2010, 2013, and 2015 AmendmentsIMPACT SOUND INSULATION TEST:

BS EN ISO 140 - Part 7:1998: Acoustics - measurement of sound in buildings and of building elements BS EN ISO 717 - Part 2:1997: Acoustics - rating of sound in buildings and of building elements

Page 4: 54 51 58 54 52 Test Result (dB) Volume (m3) Volume (m3 ... · Sound Insulation Testing Report This report has been prepared in accordance with the requirements of the reporting standard

Airtight & Noisechec5319Test Job Ref:

Registered Sound Insulation Test CertificateTest No: ATTMA Membership No: 900411078 Testing Org. Name:

GU34 3JQ

AB1 DEVELOPMENTS Customer

Address The Plestor

Selborne

Alton

Hampshire

Postcode

Job Address

99-101 London Road

Cowplain

Hampshire

England

PO8 8XJ

Latchmore House

Postcode

Test Type Airborne (Floor)

10/08/2018Test Date

Tester Mark Witcher

Site Type

Site Build

Material Change of Use

Dwelling-House/Flat

Source Room: Partition: Receiver Room:

Description GROUND FLOOR FLAT 1 Living Room 1 1ST FLOOR FLAT 7 Living Room 1

Volume / Area 51.0 m3 21.1 m2 49.0 m3

Frequency(Hz)

DnT1/3 Octave

(dB)

HighBGnd

50 Hz* 35.5

63 Hz* 27.6

80 Hz* 33.3

100 Hz 39.0

125 Hz 39.5

160 Hz 50.1

200 Hz 51.9

250 Hz 56.9

315 Hz 62.1

400 Hz 63.7 X

500 Hz 65.9 X

630 Hz 63.6 X

800 Hz 60.1 X

1 KHz 53.6 X

1.25 KHz 56.2 X

1.6 KHz 61.8 X

2 KHz 65.9 X

2.5 KHz 68.4 X

3.15 KHz 70.6 X

4 KHz* 73.2 X

5 KHz* 75.4 X

Evaluation based on field measurement usingresults obtained by an engineering method

*Outside scope of accreditation Above graph shows frequency range according to the curve of reference values within ISO 717-1

DnT,w(C ; Ctr) [dB]: 60 (-2; -6) dB PASSDnT,w + Ctr [dB]: 54 dB

Minimum Pass Level [dB]: 43 dB Adverse Aggregated Deviations [dB]: 27.8 dB

The test reported on this certificate was carried out in accordance with an approved testing procedure. If it was necessary to deviate fromthis procedure in any way, these deviations are described here:

AIRBORNE SOUND INSULATION TEST: Approved Document E (2003) including 2004, 2010, 2013, and 2015 Amendments

BS EN ISO 140 - Part 4:1998: Acoustics - measurement of sound in buildings and of building elements BS EN ISO 717 - Part 1:1997: Acoustics - rating of sound in buildings and of building elements

Page 5: 54 51 58 54 52 Test Result (dB) Volume (m3) Volume (m3 ... · Sound Insulation Testing Report This report has been prepared in accordance with the requirements of the reporting standard

Airtight & Noisechec5319Test Job Ref:

Registered Sound Insulation Test CertificateTest No: ATTMA Membership No: 900411079 Testing Org. Name:

GU34 3JQ

AB1 DEVELOPMENTS Customer

Address The Plestor

Selborne

Alton

Hampshire

Postcode

Job Address

99-101 London Road

Cowplain

Hampshire

England

PO8 8XJ

Latchmore House

Postcode

Test Type Airborne (Wall)

10/08/2018Test Date

Tester Mark Witcher

Site Type

Site Build

Material Change of Use

Dwelling-House/Flat

Source Room: Partition: Receiver Room:

Description 1ST FLOOR FLAT 7 Living Room 1 1ST FLOOR FLAT 8 Living Room 1

Volume / Area 49.0 m3 15.8 m2 49.0 m3

Frequency(Hz)

DnT1/3 Octave

(dB)

HighBGnd

50 Hz* 30.8 X

63 Hz* 29.9

80 Hz* 41.5

100 Hz 45.9

125 Hz 47.3

160 Hz 54.7

200 Hz 56.1

250 Hz 60.1

315 Hz 61.6

400 Hz 62.5

500 Hz 65.4 X

630 Hz 62.3 X

800 Hz 58.6 X

1 KHz 56.3 X

1.25 KHz 59.7 X

1.6 KHz 62.0 X

2 KHz 62.8 X

2.5 KHz 65.0 X

3.15 KHz 67.7 X

4 KHz* 70.9 X

5 KHz* 71.7 X

Evaluation based on field measurement usingresults obtained by an engineering method

*Outside scope of accreditation Above graph shows frequency range according to the curve of reference values within ISO 717-1

DnT,w(C ; Ctr) [dB]: 62 (-2; -4) dB PASSDnT,w + Ctr [dB]: 58 dB

Minimum Pass Level [dB]: 43 dB Adverse Aggregated Deviations [dB]: 29.3 dB

The test reported on this certificate was carried out in accordance with an approved testing procedure. If it was necessary to deviate fromthis procedure in any way, these deviations are described here:

AIRBORNE SOUND INSULATION TEST: Approved Document E (2003) including 2004, 2010, 2013, and 2015 Amendments

BS EN ISO 140 - Part 4:1998: Acoustics - measurement of sound in buildings and of building elements BS EN ISO 717 - Part 1:1997: Acoustics - rating of sound in buildings and of building elements

Page 6: 54 51 58 54 52 Test Result (dB) Volume (m3) Volume (m3 ... · Sound Insulation Testing Report This report has been prepared in accordance with the requirements of the reporting standard

Airtight & NoisechecTesting Org. Name:11080 9004ATTMA Membership No:Test No:

Registered Sound Insulation Test CertificateTest Job Ref: 5319

GU34 3JQ

AB1 DEVELOPMENTS Customer

Address The Plestor

Selborne

Alton

Hampshire

Postcode

Job Address

99-101 London Road

Cowplain

Hampshire

England

PO8 8XJ

Latchmore House

Postcode

Test Type Impact (Floor)

10/08/2018Test Date

Tester Mark Witcher

Site Type

Site Build

Material Change of Use

Dwelling-House/Flat

Source Room: Partition: Receiver Room:

Description 2ND FLOOR FLAT 10 Living Room 1 1ST FLOOR FLAT 7 Living Room 1

Volume / Area 83.0 m3 20.5 m2 49.0 m3

Frequency(Hz)

DnT1/3 Octave

(dB)

HighBGnd

50 Hz* 69.6

63 Hz* 66.2

80 Hz* 53.7

100 Hz 61.4

125 Hz 61.6

160 Hz 61.1

200 Hz 59.6

250 Hz 53.2

315 Hz 44.8

400 Hz 40.2

500 Hz 37.5

630 Hz 31.6 X

800 Hz 30.6 X

1 KHz 31.9 X

1.25 KHz 29.3 X

1.6 KHz 24.5 X

2 KHz 20.2 X

2.5 KHz 16.7 X

3.15 KHz 15.9 X

4 KHz* 16.5 X

5 KHz* 13.9 X

Evaluation based on field measurement usingresults obtained by an engineering method

*Outside scope of accreditation Above graph shows frequency range according to the curve of reference values within ISO 717-2

PASSLnT,w(CI) [dB]: 51 (1) dB

Maximum Pass Level [dB]: 64 dBAdverse Aggregated Deviations [dB]: 31.9 dB

The test reported on this certificate was carried out in accordance with an approved testing procedure. If it was necessary to deviate fromthis procedure in any way, these deviations are described here:

Approved Document E (2003) including 2004, 2010, 2013, and 2015 AmendmentsIMPACT SOUND INSULATION TEST:

BS EN ISO 140 - Part 7:1998: Acoustics - measurement of sound in buildings and of building elements BS EN ISO 717 - Part 2:1997: Acoustics - rating of sound in buildings and of building elements

Page 7: 54 51 58 54 52 Test Result (dB) Volume (m3) Volume (m3 ... · Sound Insulation Testing Report This report has been prepared in accordance with the requirements of the reporting standard

Airtight & Noisechec5319Test Job Ref:

Registered Sound Insulation Test CertificateTest No: ATTMA Membership No: 900411081 Testing Org. Name:

GU34 3JQ

AB1 DEVELOPMENTS Customer

Address The Plestor

Selborne

Alton

Hampshire

Postcode

Job Address

99-101 London Road

Cowplain

Hampshire

England

PO8 8XJ

Latchmore House

Postcode

Test Type Airborne (Floor)

10/08/2018Test Date

Tester Mark Witcher

Site Type

Site Build

Material Change of Use

Dwelling-House/Flat

Source Room: Partition: Receiver Room:

Description 1ST FLOOR FLAT 7 Living Room 1 2ND FLOOR FLAT 10 Living Room 1

Volume / Area 49.0 m3 20.5 m2 83.0 m3

Frequency(Hz)

DnT1/3 Octave

(dB)

HighBGnd

50 Hz* 31.0 X

63 Hz* 30.9

80 Hz* 33.7

100 Hz 39.3

125 Hz 41.5

160 Hz 50.7

200 Hz 48.6

250 Hz 54.2

315 Hz 64.2 X

400 Hz 65.6 X

500 Hz 64.1 X

630 Hz 63.0 X

800 Hz 58.7 X

1 KHz 54.0 X

1.25 KHz 57.6 X

1.6 KHz 62.9 X

2 KHz 66.1 X

2.5 KHz 68.1 X

3.15 KHz 69.3 X

4 KHz* 72.0 X

5 KHz* 73.8 X

Evaluation based on field measurement usingresults obtained by an engineering method

*Outside scope of accreditation Above graph shows frequency range according to the curve of reference values within ISO 717-1

DnT,w(C ; Ctr) [dB]: 60 (-2; -6) dB PASSDnT,w + Ctr [dB]: 54 dB

Minimum Pass Level [dB]: 43 dB Adverse Aggregated Deviations [dB]: 25.4 dB

The test reported on this certificate was carried out in accordance with an approved testing procedure. If it was necessary to deviate fromthis procedure in any way, these deviations are described here:

AIRBORNE SOUND INSULATION TEST: Approved Document E (2003) including 2004, 2010, 2013, and 2015 Amendments

BS EN ISO 140 - Part 4:1998: Acoustics - measurement of sound in buildings and of building elements BS EN ISO 717 - Part 1:1997: Acoustics - rating of sound in buildings and of building elements