49182587 Revision D

10
8 7 6 5 4 3 2 1 8 7 6 5 1 2 3 D C B A D C A B 4 COPYRIGHT @ 2018 Ingersoll Rand ALL RIGHTS RESERVED CAD GENERATED DRAWING, NO MANUAL REVISIONS ALLOWED DRAWING CONFORMS TO ASME Y14.5M - 1994 DO NOT SCALE DRAWING PROPRIETARY NOTICE UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED UNLESS OTHERWISE SPECIFIED: - REMOVE ALL BURRS AND SHARP CORNERS - WELD SYMBOLS TO BE IN ACCORDANCE WITH ANSI/AWS A2.4 THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM. WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS. THIRD ANGLE PROJECTION PART NO. ESTIMATED WEIGHT (KG UNLESS OTHERWISE SPECIFIED) A1 NAME SIZE MODEL SHEET REVISION SCALE R GENERAL ARRANGEMENT TOLERANCES ALL DIMENSIONS ARE IN MILLIMETERS [INCHES (IF SHOWN)] UNSPECIFIED TOLERANCES: ANGLES .X WHOLE : : : 13.0[.50] 6.0[.25] 1 Ingersoll-Rand Industrial Technologies CUSTOMER CONNECTION ITEM DESCRIPTION COMMENTS A PACKAGE AIR INLET (COMPRESSOR) B PACKAGE AIR EXHAUST (COMPRESSOR) C PACKAGE AIR INLET (DRYER) D PACKAGE AIR EXHAUST (DRYER) E CONDENSATE DRAIN (MOISTURE SEPARATOR) .25 INCH NPT (FEMALE) F CONDENSATE DRAIN (FILTER) .25 INCH NPT (FEMALE) G CONDENSATE DRAIN (DRYER) .25 INCH NPT (FEMALE) H ELECTRICAL INLET 120 BLANK PLATE SUPPLIED J DISCHARGE AIR 1.5 INCH (FEMALE) K ELECTRICAL INLET PG21 - REMOTE VSD ONLY L CONTROL WIRE 1 PG9 - REMOTE VSD ONLY M CONTROL WIRE 2 PG13.5 - REMOTE VSD ONLY N CONTROL WIRE 3 PG9 - REMOTE VSD ONLY DRAWN DATE J.WANG 2015AUG21 CHECKED DATE E.LIU 2015AUG21 APPROVED DATE WJ.ZHU 2015AUG21 DRAWING TYPE General Arrangement Drawing NOMENCLATURE GENERAL ARRANGEMENT, RS30-37i,n SEE NOTES 49182587 D 0.20 RS30-37i,n 10 OF 1 D.10 REVISIONS APP'D DRAWN DATE DESCRIPTION ECN REV ZONE WJ.ZHU J.WANG 2015AUG21 ORIGINAL RELEASE 1008708 A XH.ZHONG T.WU 2017FEB22 ADD DIM 665.0 ADD DIM 655.0 1201505 B 3-A1 4-A1 R.BOOKHOUT M.PRASHANT 2017DEC12 UPDATED NOTE 12 1280411 C XH.ZHONG T.WU 2018JAN19 NOTE1: ADD RS30n VFD Remote & RS37n VFD Remote CUSTOMER CONNECTION ADD K, L, M, N. ADD SHEET 9 ADD NOTE 19 1292258 D D7 D6 A8 NOTES: 1. WEIGHT (APPROXIMATE): RS30i - 1045 KG (2304 LBS) RS37i - 1095 KG (2414 LBS) RS30i TAS - 1150 KG (2535 LBS) RS37i TAS - 1200 KG (2646 LBS) RS30n - 1095 KG (2414 LBS) RS37n - 1145 KG (2524 LBS) RS30n TAS - 1200 KG (2646 LBS) RS37n TAS - 1250 KG (2750 LBS) RS30n VFD Remote - 1160 KG (2557 LBS) RS37n VFD Remote - 1210 KG (2668 LBS) ONLY MAIN PACKAGE WEIGHT FOR VFD REMOTE UNIT. AND THE WEIGHT OF VFD SHOWED IN PAGE 9. 2. USE FORK LIFT TUBES FOR MACHINE LIFTING. 3. COOLING AIR FLOW: 60HZ-6900M3/HOUR (4060 CFM) 50HZ-7200M3/HOUR (4237 CFM) 4. PIPE CONDENSATE DRAIN LINES SEPARATELY TO BASE DUE TO DIFFERENCES IN DRAIN PRESSURES. READ OPERATIONS MANUAL AND CHECK LOCAL REGULATIONS. 5. LUBRICANT FILL QUANTITY: 13.7 LITRES (3.7 US GALLONS) 6. RECOMMENDED CLEARANCE ON 3 SIDES 1 METER (40 INCHES); THE STARTER BOX SIDE IS 1.2 METERS (47 INCHES) OR MINIMUM AS REQUIRED BY LATEST NATIONAL ELECTRICAL CODE OR APPLICABLE LOCAL CODES. 7. EXTERNAL PIPING SHOULD NOT EXERT ANY UNRESOLVED MOMENTS OR FORCES ON UNIT. USE PIPE OF EQUAL OR GREATER SIZE AT DISCHARGE LOCATION OF UNIT. 8. THERE SHOULD BE NO PLASTIC OR PVC PIPING ATTACHED TO THIS UNIT OR USED FOR ANY LINES DOWNSTREAM. 9. REMOVE THE ISOLATION MOUNT RESTRAINTS BEFORE THE INITIAL START. THE RESTRAINTS CAN BE DISCARDED. 10. FIELD INSTALLED DUCTING TO AND FROM COMPRESSOR CANNOT ADD MORE THAN 6MM (.25 INCH) OF WATER TOTAL AIR RESISTANCE. 11. UNIT HAS AN INTERNAL DISCHARGE CHECK VALVE, EXTERNAL CHECK VALVE NOT REQUIRED. ISOLATION VALVE REQUIRED WITHIN 915 MM (36 INCHES) OF THE COMPRESSOR DISCHARGE. 12. COMPRESSOR MUST BE INSTALLED ON A LEVEL FLOOR CAPABLE OF SUPPORTING ENTIRE CONTACT SURFACE OF THE BASE FRAME. COMPRESSOR SHOULD BE BOLTED TO THE FLOOR WITH FOUR (4) M16 (3/4 INCH) BOLTS USING HOLES SHOWN ON SHEET 5. SEAL BASE TO FLOOR WITH CORK OR RUBBER. 13. DO NOT PIPE INTO A COMMON HEADER WITH A RECIPROCATING COMPRESSOR. UNLESS RECIP COMPRESSOR UTILIZES A DISHCHARGE PULSATION DAMPENER. 14. DENOTES CENTER OF GRAVITY. 15. SIZING OF ELECTRICAL COMPONENTS NOT SUPPLIED BY INGERSOLL-RAND IS THE RESPONSIBILITY OF THE CUSTOMER AND SHOULD BE DONE IN ACCORDANCE WITH THE INFORMATION ON THE COMPRESSOR DATA PLATE, NATIONAL AND LOCAL ELECTRIC CODES. 16. A BLANK GLAND PLATE IS PROVIDED FOR ELECTRICAL POWER INLET AS INDICATED. 17. WHEN INSTALLED INDOORS IN A CONFINED SPACE, THE COOLING AIR INLET OR EXHAUST MUST BE DUCTED AWAY FROM UNIT TO PREVENT RECIRCULATION OF HOT EXHAUST AIR. 18. CONNECTION LEGEND - ALL 60 Hz CONNECTIONS ARE NPT (UNLESS SPECIFIED OTHERWISE) - ALL 50 Hz CONNECTIONS ARE BSPT (UNLESS SPECIFIED OTHERWISE) 19. VFD REMOTE UNITS ARE ONLY AVAILABLE FOR NA. THIRD ANGLE PROJECTION 28-Mar-2018 10:30:33 (model D.3/D.10)

Transcript of 49182587 Revision D

Page 1: 49182587 Revision D

8 7 6 5 4 3 2 1

8 7 6 5 123

D

C

B

A

D

C

A

B

4

COPYRIGHT @ 2018Ingersoll Rand

ALL RIGHTS RESERVED

CAD GENERATED DRAWING,NO MANUAL REVISIONS ALLOWED

DRAWING CONFORMS TOASME Y14.5M - 1994

DO NOT SCALE DRAWING

PROPRIETARY NOTICE

UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

UNLESS OTHERWISE SPECIFIED:- REMOVE ALL BURRS AND SHARP CORNERS- WELD SYMBOLS TO BE IN ACCORDANCE WITH ANSI/AWS A2.4

THIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZED IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.

WARNING: THE EXPORT OR REEXPORT OF THIS DRAWING OR A PRODUCT PRODUCED BY THIS DRAWING IS SUBJECT TO U.S. EXPORT ADMINISTRATION REGULATIONS AND OTHER APPLICABLE GOVERNMENT RESTRICTIONS OR REGULATIONS.

THIRD ANGLE PROJECTION

PART NO.ESTIMATED WEIGHT(KG UNLESS OTHERWISE SPECIFIED)A1

NAME

SIZE

MODEL SHEET

REVISION

SCALE

R

GENERAL ARRANGEMENTTOLERANCES

ALL DIMENSIONS ARE IN MILLIMETERS

[INCHES (IF SHOWN)]

UNSPECIFIED TOLERANCES:

ANGLES .X

WHOLE :::

13.0[.50] 6.0[.25] 1

Ingersoll-Rand Industrial Technologies

CUSTOMER CONNECTIONITEM DESCRIPTION COMMENTS

A PACKAGE AIR INLET (COMPRESSOR)B PACKAGE AIR EXHAUST (COMPRESSOR)C PACKAGE AIR INLET (DRYER)D PACKAGE AIR EXHAUST (DRYER)E CONDENSATE DRAIN (MOISTURE SEPARATOR) .25 INCH NPT (FEMALE)F CONDENSATE DRAIN (FILTER) .25 INCH NPT (FEMALE)G CONDENSATE DRAIN (DRYER) .25 INCH NPT (FEMALE) H ELECTRICAL INLET 120 BLANK PLATE SUPPLIED J DISCHARGE AIR 1.5 INCH (FEMALE) K ELECTRICAL INLET PG21 - REMOTE VSD ONLYL CONTROL WIRE 1 PG9 - REMOTE VSD ONLYM CONTROL WIRE 2 PG13.5 - REMOTE VSD ONLYN CONTROL WIRE 3 PG9 - REMOTE VSD ONLY

DRAWN DATE

J.WANG 2015AUG21CHECKED DATE

E.LIU 2015AUG21APPROVED DATE

WJ.ZHU 2015AUG21DRAWING TYPE

General Arrangement DrawingNOMENCLATURE

GENERAL ARRANGEMENT,RS30-37i,n GENERAL ARRANGEMENT, RS30-37i,n

SEE NOTES mdl.param.value 49182587 D0.20 RS30-37i,n 10 OF 1

For Internal Use : Model = 49182587 | ASSEM | D.3 | Tian Wu | 28-Mar-18 10:03:28 AM | Design Drawing = 49182587 | DRAW | D.10 | Tian Wu | 28-Mar-18 10:27:26 AM | Design

D.10

REVISIONSAPP'DDRAWNDATEDESCRIPTIONECNREVZONE

WJ.ZHUJ.WANG2015AUG21ORIGINAL RELEASE1008708AXH.ZHONGT.WU2017FEB22ADD DIM 665.0

ADD DIM 655.01201505B3-A1

4-A1R.BOOKHOUTM.PRASHANT2017DEC12UPDATED NOTE 121280411CXH.ZHONGT.WU2018JAN19NOTE1: ADD RS30n VFD Remote & RS37n VFD Remote

CUSTOMER CONNECTION ADD K, L, M, N.ADD SHEET 9ADD NOTE 19

1292258DD7D6

A8

NOTES: 1. WEIGHT (APPROXIMATE): RS30i - 1045 KG (2304 LBS) RS37i - 1095 KG (2414 LBS) RS30i TAS - 1150 KG (2535 LBS) RS37i TAS - 1200 KG (2646 LBS) RS30n - 1095 KG (2414 LBS) RS37n - 1145 KG (2524 LBS) RS30n TAS - 1200 KG (2646 LBS) RS37n TAS - 1250 KG (2750 LBS) RS30n VFD Remote - 1160 KG (2557 LBS) RS37n VFD Remote - 1210 KG (2668 LBS) ONLY MAIN PACKAGE WEIGHT FOR VFD REMOTE UNIT. AND THE WEIGHT OF VFD SHOWED IN PAGE 9. 2. USE FORK LIFT TUBES FOR MACHINE LIFTING. 3. COOLING AIR FLOW: 60HZ-6900M3/HOUR (4060 CFM) 50HZ-7200M3/HOUR (4237 CFM) 4. PIPE CONDENSATE DRAIN LINES SEPARATELY TO BASE DUE TO DIFFERENCES IN DRAIN PRESSURES. READ OPERATIONS MANUAL AND CHECK LOCAL REGULATIONS. 5. LUBRICANT FILL QUANTITY: 13.7 LITRES (3.7 US GALLONS) 6. RECOMMENDED CLEARANCE ON 3 SIDES 1 METER (40 INCHES); THE STARTER BOX SIDE IS 1.2 METERS (47 INCHES) OR MINIMUM AS REQUIRED BY LATEST NATIONAL ELECTRICAL CODE OR APPLICABLE LOCAL CODES. 7. EXTERNAL PIPING SHOULD NOT EXERT ANY UNRESOLVED MOMENTS OR FORCES ON UNIT. USE PIPE OF EQUAL OR GREATER SIZE AT DISCHARGE LOCATION OF UNIT. 8. THERE SHOULD BE NO PLASTIC OR PVC PIPING ATTACHED TO THIS UNIT OR USED FOR ANY LINES DOWNSTREAM. 9. REMOVE THE ISOLATION MOUNT RESTRAINTS BEFORE THE INITIAL START. THE RESTRAINTS CAN BE DISCARDED. 10. FIELD INSTALLED DUCTING TO AND FROM COMPRESSOR CANNOT ADD MORE THAN 6MM (.25 INCH) OF WATER TOTAL AIR RESISTANCE. 11. UNIT HAS AN INTERNAL DISCHARGE CHECK VALVE, EXTERNAL CHECK VALVE NOT REQUIRED. ISOLATION VALVE REQUIRED WITHIN 915 MM (36 INCHES) OF THE COMPRESSOR DISCHARGE. 12. COMPRESSOR MUST BE INSTALLED ON A LEVEL FLOOR CAPABLE OF SUPPORTING ENTIRE CONTACT SURFACE OF THE BASE FRAME. COMPRESSOR SHOULD BE BOLTED TO THE FLOOR WITH FOUR (4) M16 (3/4 INCH) BOLTS USING HOLES SHOWN ON SHEET 5. SEAL BASE TO FLOOR WITH CORK OR RUBBER. 13. DO NOT PIPE INTO A COMMON HEADER WITH A RECIPROCATING COMPRESSOR. UNLESS RECIP COMPRESSOR UTILIZES A DISHCHARGE PULSATION DAMPENER. 14. DENOTES CENTER OF GRAVITY. 15. SIZING OF ELECTRICAL COMPONENTS NOT SUPPLIED BY INGERSOLL-RAND IS THE RESPONSIBILITY OF THE CUSTOMER AND SHOULD BE DONE IN ACCORDANCE WITH THE INFORMATION ON THE COMPRESSOR DATA PLATE, NATIONAL AND LOCAL ELECTRIC CODES. 16. A BLANK GLAND PLATE IS PROVIDED FOR ELECTRICAL POWER INLET AS INDICATED. 17. WHEN INSTALLED INDOORS IN A CONFINED SPACE, THE COOLING AIR INLET OR EXHAUST MUST BE DUCTED AWAY FROM UNIT TO PREVENT RECIRCULATION OF HOT EXHAUST AIR. 18. CONNECTION LEGEND - ALL 60 Hz CONNECTIONS ARE NPT (UNLESS SPECIFIED OTHERWISE) - ALL 50 Hz CONNECTIONS ARE BSPT (UNLESS SPECIFIED OTHERWISE) 19. VFD REMOTE UNITS ARE ONLY AVAILABLE FOR NA.

THIRD ANGLE PROJECTION

28-Mar-2018 10:30:33 (model D.3/D.10)

Page 2: 49182587 Revision D

8 7 6 5 4 3 2 1

8 7 6 5 123

D

C

B

A

D

C

A

B

4

PROPRIETARY NOTICETHIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.

UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

NAME

A1SCALE SHEET

REVISIONSIZE

NOMENCLATURE

DWG NO.

PART NO.

GENERAL ARRANGEMENT,RS30-37i,n

GENERAL ARRANGEMENT, RS30-37i,n

49182587 49182587 D0.20 10 OF 2

D.10

FRONT

LEFT ENDREARRIGHT END

TOP

28-Mar-2018 10:30:33 (model D.3/D.10)

Page 3: 49182587 Revision D

8 7 6 5 4 3 2 1

8 7 6 5 123

D

C

B

A

D

C

A

B

4

PROPRIETARY NOTICETHIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.

UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

NAME

A1SCALE SHEET

REVISIONSIZE

NOMENCLATURE

DWG NO.

PART NO.

923.2[36.3]

487.0[19.2]

98.0[3.9]

50.0[2.0]

332.0[13.1]

1534.0[60.4]

1937.0[76.3]

1136.8[44.8]

295.5[11.6]

297.0[11.7]

164.0[6.5]

895.5[35.3]

337.3[13.3]

112.0[4.4]

1056.0[41.6]

836.04[32.92]

4.0[0.2]

239.8[9.4]

457.3[18.0]

196.0[7.7]

484.0[19.1]

898.3[35.4]VSD

971.8[38.3]

FIXED SPEED

624.2[24.6]

FIXED SPEED

680.4[26.8]VSD

665.0[26.2]

FOR REFERENCE

GENERAL ARRANGEMENT,RS30-37i,n

GENERAL ARRANGEMENT, RS30-37i,n

49182587 49182587 D0.20 10 OF 3

D.10

OPTION: NON - TAS

LEFT END VIEW

A

B

FRONT VIEW

TOP VIEW

JH

SEE DETAIL ASCALE 1.000

ADETAIL

AIR

FLO

W

AIR FLOW

28-Mar-2018 10:30:33 (model D.3/D.10)

Page 4: 49182587 Revision D

8 7 6 5 4 3 2 1

8 7 6 5 123

D

C

B

A

D

C

A

B

4

PROPRIETARY NOTICETHIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.

UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

NAME

A1SCALE SHEET

REVISIONSIZE

NOMENCLATURE

DWG NO.

PART NO.

923.2[36.3]

332.0[13.1]

1136.8[44.8]

295.5[11.6]

1534.0[60.4]

164.0[6.5]

297.0[11.7]

1937.0[76.3]

279.0[11.0]

895.5[35.3]

337.3[13.3]

400.0[15.7]

112.0[4.4]

836.0[32.9]

4.0[0.2]

113.5[4.5]

547.9[21.6]

196.0[7.7]

484.0[19.1]

239.8[9.4]248.8[9.8]

334.0[13.2]

457.3[18.0]

744.0[29.3]

478.0[18.8]

327.0[12.9]

1056.0[41.6]

882.30[34.74]VSD

953.80[37.55]

FIXED SPEED

649.20[25.56]

FIXED SPEED

706.30[27.81]VSD

655.0[25.8]

FOR REFERENCE

GENERAL ARRANGEMENT,RS30-37i,n

GENERAL ARRANGEMENT, RS30-37i,n

49182587 49182587 D0.20 10 OF 4

D.10

OPTION: WITH - TAS

A

TOP VIEW

C

B

FRONT VIEW

D

LEFT END VIEW

E F G

SEE DETAIL BSCALE 1.000

BDETAIL

AIR FLOW

AIR FLOW

28-Mar-2018 10:30:33 (model D.3/D.10)

AIR

FLO

W

AIR

FLO

W

Page 5: 49182587 Revision D

AA

8 7 6 5 4 3 2 1

8 7 6 5 123

D

C

B

A

D

C

A

B

4

PROPRIETARY NOTICETHIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.

UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

NAME

A1SCALE SHEET

REVISIONSIZE

NOMENCLATURE

DWG NO.

PART NO.

53.5[2.1]

1002.5[39.5]

53.5[2.1]

4 X 18.0[0.7]

771.4[30.4]

2 X 19.9[0.8]

2 X 54.0[2.1]

4 X 181.0[7.1]

2 X 771.4[30.4]

2 X 672.1[26.5]

762.6[30.0]

12.96[0.51]

GENERAL ARRANGEMENT,RS30-37i,n

GENERAL ARRANGEMENT, RS30-37i,n

49182587 49182587 D0.20 10 OF 5

D.10

REAR VIEW

(BOTH SIDES)

BOTTOM VIEW

(BOTH SIDES)(BOTH SIDES) (BOTH SIDES)

(BOTH SIDES)

A-ASECTION

SEE DETAIL C

RIGHT END VIEW

SCALE 0.500CDETAIL

J

28-Mar-2018 10:30:33 (model D.3/D.10)

Page 6: 49182587 Revision D

8 7 6 5 4 3 2 1

8 7 6 5 123

D

C

B

A

D

C

A

B

4

PROPRIETARY NOTICETHIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.

UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

NAME

A1SCALE SHEET

REVISIONSIZE

NOMENCLATURE

DWG NO.

PART NO.

4.0[0.2]THIS VALUE NEEDS TO BE ADDED TO ALL HEIGHT DIMENSIONS WHEN THIS OPTION IS PURCHASED.

GENERAL ARRANGEMENT,RS30-37i,n

GENERAL ARRANGEMENT, RS30-37i,n

49182587 49182587 D0.20 10 OF 6

D.10

GENERAL ARRANGEMENT WITHOPTIONAL CONTAINMENT BASE

FRONT VIEW

BOTTOM VIEW

FRONT

LEFT END

SEE DETAIL D

SCALE 0.700DDETAIL

28-Mar-2018 10:30:33 (model D.3/D.10)

Page 7: 49182587 Revision D

8 7 6 5 4 3 2 1

8 7 6 5 123

D

C

B

A

D

C

A

B

4

PROPRIETARY NOTICETHIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.

UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

NAME

A1SCALE SHEET

REVISIONSIZE

NOMENCLATURE

DWG NO.

PART NO.

161.05[6.34]

640.0[25.2]

282.8[11.1]

447.9[17.6]

215.1[8.5]

543.5[21.4]

152.0[6.0]

690.1[27.2]

2263.0[89.1]

326.0[12.8]

2304.0[90.7]

GENERAL ARRANGEMENT,RS30-37i,n

GENERAL ARRANGEMENT, RS30-37i,n

49182587 49182587 D0.20 10 OF 7

D.10

GENERAL ARRANGEMENT WITHOPTIONAL HIGH DUST PRE-FILTER - NO DRYER(OPTION IS NOT AVAILABLE FOR STANDARD VSD UNITS, VSD REMOTE UNIT IS AVALIABLE)

A

B

FRONT VIEW

LEFT END VIEW

FRONT

LEFT END

AIR

FLO

W

AIR FLOW

28-Mar-2018 10:30:33 (model D.3/D.10)

Page 8: 49182587 Revision D

8 7 6 5 4 3 2 1

8 7 6 5 123

D

C

B

A

D

C

A

B

4

PROPRIETARY NOTICETHIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.

UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

NAME

A1SCALE SHEET

REVISIONSIZE

NOMENCLATURE

DWG NO.

PART NO.

885.0[34.8]

87.5[3.4]

381.0[15.0]

874.0[34.4]

1585.5[62.4]

1976.7[77.8]

291.0[11.5]

446.0[17.6]

225.1[8.9]

453.3[17.8]

1915.0[75.4]

GENERAL ARRANGEMENT,RS30-37i,n

GENERAL ARRANGEMENT, RS30-37i,n

49182587 49182587 D0.20 10 OF 8

D.10

A

FRONT VIEWLEFT END VIEW

RIGHT END VIEW

B

GENERAL ARRANGEMENT WITHOPTIONAL OUTDOOR MODIFICATION(OPTION IS NOT AVAILABLE FOR TAS UNITS OR STANDARD VSD UNITS)

FRONT

LEFT END

AIR FLOW

AIR FLOW

28-Mar-2018 10:30:33 (model D.3/D.10)

Page 9: 49182587 Revision D

8 7 6 5 4 3 2 1

8 7 6 5 123

D

C

B

A

D

C

A

B

4

PROPRIETARY NOTICETHIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.

UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

NAME

A1SCALE SHEET

REVISIONSIZE

NOMENCLATURE

PART NO.

132.0[5.2]

150.0[5.9]

2X38.0[1.5]

767.5[30.2]

332.3[13.1]

369.4[14.5]

681.5[26.8]

307.4[12.1]

307.4[12.1]

40.3[1.6]

482.0[19.0]

GENERAL ARRANGEMENT,RS30-37i,n

GENERAL ARRANGEMENT, RS30-37i,n

mdl.param.value 49182587 D0.20 10 OF 9

D.10

GENERAL ARRANGEMENT WITHOPTIONAL VSD REMOTE STARTER(OPTION IS NOT AVALIABLE FOR TAS UNITS, AVAILABLE WITH OUTDOOR MODIFICATION)

K

ML

N

DRIVE, IP55/NEMA12 200-240VWEIGHT: 65 KG

DRIVE IP55/NEMA12 380-575VWEIGHT: 45KG

28-Mar-2018 10:30:33 (model D.3/D.10)

Page 10: 49182587 Revision D

8 7 6 5 4 3 2 1

8 7 6 5 123

D

C

B

A

D

C

A

B

4

PROPRIETARY NOTICETHIS DRAWING CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION, IS THE PROPERTY OF INGERSOLL-RAND CO., AND IS GIVEN TO THE RECEIVER IN CONFIDENCE. THE RECEIVER BY RECEPTION AND RETENTION OF THE DRAWING ACCEPTS THE DRAWING IN CONFIDENCE AND AGREES THAT, EXCEPT AS AUTHORIZE D IN WRITING BY INGERSOLL-RAND CO. IT WILL (1) NOT USE THE DRAWING OR ANY COPY THEREOF OR THE CONFIDENTIAL OR TRADE SECRET INFORMATION THEREIN; (2) NOT COPY THE DRAWING; (3) NOT DISCLOSE TO OTHERS EITHER THE DRAWING OR THE CONFIDENTIAL OR TRADESECRET INFORMATION THEREIN; AND (4) UPON COMPLETION OF THE NEED TO RETAIN THE DRAWING, OR UPON DEMAND, RETURN THE DRAWING, ALL COPIES THEREOF, AND ALL MATERIAL COPIED THEREFROM.

UNLESS OTHERWISE SPECIFIED PRINTED DOCUMENT IS UNCONTROLLED

NAME

A1SCALE SHEET

REVISIONSIZE

NOMENCLATURE

DWG NO.

PART NO.

161.0[6.3]

640.0[25.2]

152.0[6.0]

1382.0[54.4]

2304.1[90.7]

326.0[12.8]

2263.0[89.1]

323.7[12.7]

407.0[16.0] 178.4

[7.0]

543.3[21.4] 799.4

[31.5]

681.3[26.8]

GENERAL ARRANGEMENT,RS30-37i,n

GENERAL ARRANGEMENT, RS30-37i,n

49182587 49182587 D0.20 10 OF 10

D.10

A

B

C

D

FRONT VIEW

LEFT END VIEW

GENERAL ARRANGEMENT WITHOPTIONAL HIGH DUST PRE-FILTER - WITH DRYER(OPTION IS NOT AVAILABLE FOR VSD UNITS)

FRONT

LEFT END

AIR

FLO

W

AIR FLOW

AIR

FLO

W

AIR FLOW

28-Mar-2018 10:30:33 (model D.3/D.10)