Intra-frequency measurement reporting criteria.
The triggering of the event-triggered reporting for an intra-frequency measurement. All events concerning intra-frequency measurements are labelled 1x where x is a, b, c….
1) Event 1a:A Primary CPICH enters the Reporting Range.
2) Event 1b:A Primary CPICH leaves the Reporting Range.
3) Event 1c:A Non-active Primary CPICH becomes better than an active Primary CPICH.
4) Event 1d:Change of best cell.
5) Event 1e:A Primary CPICH becomes better than an absolute threshold.
6) Event 1f:A Primary CPICH becomes worse than an absolute threshold.
Inter-frequency measurement reporting criteria.
The triggering of the event-triggered reporting for an inter-frequency measurements. All events concerning inter-frequency measurements are labelled 2x where x is a,b,c..
1) Event 2a:Change of best frequency.
2) Event 2b:The estimated quality of the currently used frequency is below a certain threshold and the estimated quality of a non-used frequency is above a certain threshold.
3) Event 2c:The estimated quality of a non-used frequency is above a certain threshold
4) Event 2d:The estimated quality of the currently used frequency is below a certain threshold
5) Event 2e:The estimated quality of a non-used frequency is below a certain threshold
6) Event 2f:The estimated quality of the currently used frequency is above a certain threshold Inter-system measurement reporting criteria.
The triggering of the event-triggered reporting for an inter-system measurement. All events concerning inter-system measurements are labelled 3x where x is a,b,c..
1) Event 3a:The estimated quality of the currently used UTRAN frequency is below a certain threshold and the estimated quality of the other system is above a certain threshold.
2) Event 3b:The estimated quality of other system is below a certain threshold
3) Event 3c:The estimated quality of other system is above a certain threshold
![Page 2: 3g Events Complete](https://reader036.fdocuments.in/reader036/viewer/2022082906/577cc9a61a28aba711a44b2b/html5/thumbnails/2.jpg)
4) Event 3d:Change of best cell in other system Traffic volume measurement reporting criteria.
Contains the measurement reporting criteria information for a traffic volume measurement.1) Event 4a:
RLC buffer payload exceeds an absolute threshold.2) Event 4b:
RLC buffer payload becomes smaller than an absolute threshold. UE internal measurement reporting criteria.
The triggering of the event-triggered reporting for a UE internal measurement. All events concerning UEinternal measurements are labelled 6x where x is a, b, c…. In TDD, the events 6a - 6d are measured andreported on timeslot basis.
1) Event 6a:The UE Transmitted Power becomes larger than an absolute threshold
2) Event 6b:The UE Transmitted Power becomes less than an absolute threshold
3) Event 6c:The UE Transmitted Power reaches its minimum value
4) Event 6d:The UE Transmitted Power reaches its maximum value
5) Event 6e:The UE RSSI reaches the UEs dynamic receiver range
6) Event 6f:The UE Rx-Tx time difference for a RL included in the active set becomes larger than anabsolute threshold
7) Event 6g:The UE Rx-Tx time difference for a RL included in the active set becomes less than an absolute threshold.