350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint...

11
Equipment Manufacturer 350-1743

Transcript of 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint...

Page 1: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

Equipment Manufacturer350-1743

Page 2: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

Equipment Manufacturer350-1743

Page 3: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

0

.5 1.0

05'

Meters2.0 3.0

10'

TRANSFER

STATION

W/ STEP

36"

0,92M

72"

1,83M

72"

1,83M

36"

0,92M

37'-11"

[11.57M]

37'-2"

[11.34M]

6'-1"

[1.86M]

6'-1"

[1.86M]

6'-1"

[1.85M]

6'

[1.84M]

6'

[1.84M]

6'-2"

[1.87M]

6'-6"

[1.99M]

6'-1"

[1.84M]

6'-1"

[1.86M]

6'-4"

[1.94M]

ROUNDABOUT

W/ OVERHEAD

LADDER

GLIDE

SLIDE

POST

MOUNT

BELLS

LEG

LIFT

ADA

STAIRS

SMALL

ANGLED

CLIMBER

LARGE

ANGLED

CLIMBER

SILO

CLIMBER

ADVENTURE

BRIDGE

GLIDE

SLIDE

ARCH

BRIDGE

SLIDING

POLE

INCLINED

CLIFF

HANGER

RIBBON

CLIMBER

POST

MOUNT

WHEEL

CABANA

ROOF

Total Elevated Play Activities:

Total Ground-Level Play Activities:

AccessibleElevatedActivities

AccessibleGround-Level

Activities

AccessibleGround-LevelPlay Types

Required

Provided

AD

A S

CH

EDU

LE 10

5

10

4

3

4

3

3

PLAYWORLD SYSTEMS, INC.

1000 Buffalo Road

Lewisburg, PA

17837-9795 USA

BPaper Size

DATE:

SCALE:PROJECT NO:

*PLAYGROUND SUPERVISION REQUIRED

DRAWN BY:

USER CAPACITY: AGE GROUP:

AREA: PERIMETER:

EQUIPMENT SIZE:

USE ZONE:

FALL HEIGHT:

CPSC #325ASTM F1487-

350-

1743

SA

LE

S

TR

UC

TU

RE

350-1743A 3/16"=1'-0"

M. MERTZ

20-DEC-17

25'9" x 25'1" x 15'8"7,87M x 7,65M x 4,77M

37'11" x 37'2"11,57M x 11,34M

1,081 SqFt.100,42 SqM.

127 Ft.38,71M

8 Ft.2,44M

44 5-12

17

Page 4: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

0

.5 1.0

05'

Meters2.0 3.0

10'

36"

0,92M

72"

1,83M

72"

1,83M

36"

0,92M

37'-11"

[11.57M]

37'-2"

[11.34M]

6'-1"

[1.86M]

6'-1"

[1.86M]

6'-1"

[1.85M]

6'

[1.84M]

6'

[1.84M]

6'-2"

[1.87M]

6'-6"

[1.99M]

6'-1"

[1.84M]

6'-1"

[1.86M]

6'-4"

[1.94M]

7

8

9

10

11

12

13

14

15

16

17

18

1920

21

22

23

24

25

26

27

Total Elevated Play Activities:

Total Ground-Level Play Activities:

AccessibleElevatedActivities

AccessibleGround-Level

Activities

AccessibleGround-LevelPlay Types

Required

Provided

AD

A S

CH

EDU

LE 10

5

10

4

3

4

3

3

PLAYWORLD SYSTEMS, INC.

1000 Buffalo Road

Lewisburg, PA

17837-9795 USA

BPaper Size

DATE:

SCALE:PROJECT NO:

*PLAYGROUND SUPERVISION REQUIRED

DRAWN BY:

USER CAPACITY: AGE GROUP:

AREA: PERIMETER:

EQUIPMENT SIZE:

USE ZONE:

FALL HEIGHT:

CPSC #325ASTM F1487-

350-

1743

SA

LE

S

TR

UC

TU

RE

350-1743A 3/16"=1'-0"

M. MERTZ

20-DEC-17

25'9" x 25'1" x 15'8"7,87M x 7,65M x 4,77M

37'11" x 37'2"11,57M x 11,34M

1,081 SqFt.100,42 SqM.

127 Ft.38,71M

8 Ft.2,44M

44 5-12

17

Page 5: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

DATE:

SCALE:

DRAWN BY:

SPIRAL SLIDE CENTER POST FOOTING (DETAIL1)

SUPPORT POST FOOTING (DETAIL 1 or 4) INDICATES POST LENGTH)

CANTILEVER, "T" POST, AND COMPONENTPOST FOOTING (DETAIL 2)

(ZZCH1850 INDICATES PART NUMBER)

GROUND ZERO POST FOOTING (DETAIL 2) INDICATES POST LENGTH)

COMPONENT FOOTING (DETAIL 3)

(112"

(144"

Page 6: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

T

R

A

N

S

F

E

R

S

T

A

T

I

O

N

T

R

A

N

S

F

E

R

S

T

A

T

I

O

N

1

3

6

"

1

3

6

"

1

3

6

"

1

3

6

"

1

2

4

"

1

2

4

"

1

2

4

"

1

2

4

"

1

2

4

"

1

6

0

"

1

6

0

"

1

6

0

"

1

6

0

"

2

0

0

"

2

0

0

"

2

0

0

"

2

0

0

"

1

4

8

"

36"36" 72" 36"36"

26"

21"

7"

20"

18"

93"

18"

73"

36"36" 72" 36"36" 5" 20"

8"

120"

9" 17"9"

54"

18"

32"

18"

19"

16"

16" 41"

31"

11"

14"

TRANSFER

STATION

W/ STEP

ROUNDABOUT

W/ OVERHEAD

LADDER

GLIDE

SLIDE

ADA

STAIRS

LARGE & SMALL

ANGLED

CLIMBERS

SILO

CLIMBER

ADVENTURE

BRIDGE

GLIDE

SLIDE

ARCH

BRIDGE

SLIDING

POLE

INCLINED

CLIFF

HANGER

RIBBON

CLIMBER

132"

98"

87"

179"

73"

PLAYWORLD SYSTEMS, INC.

1000 Buffalo Road

Lewisburg, PA

17837-9795 USA

BPaper Size

DATE:

SCALE:PROJECT NO:

*PLAYGROUND SUPERVISION REQUIRED

DRAWN BY:

FOOTING LEGEND

1

1

2

"

1

8

5

0

Z

Z

C

H

1

4

4

"

G

Z

SPIRAL SLIDE CENTER POST FOOTING (DETAIL1)

SUPPORT POST FOOTING (DETAIL 1 or 4)(112" INDICATES POST LENGTH)

CANTILEVER, "T" POST, AND COMPONENTPOST FOOTING (DETAIL 2)

(ZZCH1850 INDICATES PART NUMBER)

GROUND ZERO POST FOOTING (DETAIL 2)(144" INDICATES POST LENGTH)

COMPONENT FOOTING (DETAIL 3)

350-

1743

SA

LE

S

TR

UC

TU

RE

350-1743A 3/16"=1'-0"

M. MERTZ

22-DEC-17

Page 7: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

Posts

ZZCH0018 51 3.5in OD x 124in STEEL POST W/RIVETED CAP

ZZCH0028 42 3.5in OD x 136in STEEL POST W/ RIVETED CAP

ZZCH0038 13 3.5in OD x 148in STEEL POST W/ RIVETED CAP

ZZCH0048 44 3.5in OD x 160in STEEL POST W/ RIVETED CAP

ZZCH0077 45 3.5in OD x 200in STEEL POST W/O CAP

Decks & Kick Plates

ZZCH0616 46 SQUARE COATED DECK ASSEMBLY

ADA Items

ZZCH2007 17 TRANSFER STATION w/TALL GUARDRAIL (36in DECK)

ZZUN2019 18 APPROACH STEP FOR TRANSFER STATION

Slides

ZZCH2696 19 GLIDE SLIDE (72in DECK)

ZZCH3127 110 GLIDE SLIDE (36in DECK)

ZZCH8090 111 SLIDING POLE (72in DECK)

Activity Panels

ZZCH4290 112 POST MOUNTED STEERING WHEEL

Barriers

ZZCH4288 113 ACCESS GATE

Climbers

ZZCH6989 114 INCLINED CLIFF HANGER (72in DECK)

ZZCH7179 115 ANGLED CLIMBER SMALL (36in DECK)

ZZCH7196 116 ANGLED CLIMBER LARGE (72in DECK)

ZZCH7949 117 SILO CLIMBER (36in DECK)

ZZCH8310 118 RIBBON CLIMBER (72in DECK)

Overhead Events

ZZCH5770 119 LEG LIFT

ZZCH5970 120 OVERHEAD EVENT ACCESS LADDER (36in DECK)

ZZCH6966 121 10ft ROUNDABOUT HORIZONTAL LADDER

Bridges

ZZCH6595 122 6ft ARCH BRIDGE

ZZCH6597 123 6ft ADVENTURE BRIDGE w/ISO43 CHAIN

Audible Activities

ZZCH4556 124 7in BELL (POST MOUNT)

ZZCH4558 125 9in BELL (POST MOUNT)

Roofs & Arches

ZZCH9846 126 CABANA ROOF

Stairs and Ladders

ZZCH9177 127 36in ACCESS STEPPED PLATFORM (DECK TO DECK)

Additional Tool & Maintenance Kits

ZZUN1471 128 INSTALLER HARDWARE KIT

ZZUN9910 129 SURFACING WARNING LABEL KIT

ZZUN9930 130 PIPE SYSTEMS MAINTENANCE KIT W/ AEROSOL

Part No. Description

Design Number: 350-1743A - Bill Of Material

350-1743

Ref.No. Quantity

Tuesday, May 05, 2020 Page of1 2 Playworld.com

Page 8: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

ZZXX0678 131 LABEL KIT- COMPOSITE STRUCTURE - ASTM

ZZXXGNGUID 132 GENERAL INSTALLERS GUIDE

Part No. Description

Design Number: 350-1743A - Bill Of Material

350-1743

Ref.No. Quantity

Tuesday, May 05, 2020 Page of2 2 Playworld.com

Page 9: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

CertifiedZZCH00181 3.5in OD x 124in STEEL POST W/RIVETED CAP

5 194.55 269 0 5.00 0.63 0

CertifiedZZCH00282 3.5in OD x 136in STEEL POST W/ RIVETED CAP

4 174.04 234 0 4.00 0.50 0

CertifiedZZCH00383 3.5in OD x 148in STEEL POST W/ RIVETED CAP

1 47.11 63 0 1.00 0.13 0

CertifiedZZCH00484 3.5in OD x 160in STEEL POST W/ RIVETED CAP

4 200.84 272 0 4.00 0.50 0

CertifiedZZCH00775 3.5in OD x 200in STEEL POST W/O CAP4 244.04 317 0 4.00 0.50 0

CertifiedZZCH06166 SQUARE COATED DECK ASSEMBLY 4 219.44 695 12 4.00 0.00 0

CertifiedZZCH20077 TRANSFER STATION w/TALL GUARDRAIL (36in DECK)

1 148.40 310 2 2.00 0.09 0

CertifiedZZUN20198 APPROACH STEP FOR TRANSFER STATION1 35.83 72 1 1.00 0.04 0

CertifiedZZCH26969 GLIDE SLIDE (72in DECK) 1 151.63 653 2 1.50 0.03 1

CertifiedZZCH312710 GLIDE SLIDE (36in DECK)1 99.73 374 2 1.50 0.03 1

CertifiedZZCH809011 SLIDING POLE (72in DECK) 1 59.63 161 1 1.50 0.03 1

CertifiedZZCH429012 POST MOUNTED STEERING WHEEL 1 7.83 44 1 0.25 0.00 1

CertifiedZZCH428813 ACCESS GATE 1 17.34 65 0 0.50 0.00 0

CertifiedZZCH698914 INCLINED CLIFF HANGER (72in DECK)1 144.40 615 2 2.50 0.06 1

CertifiedZZCH717915 ANGLED CLIMBER SMALL (36in DECK)1 54.41 169 2 1.00 0.00 1

CertifiedZZCH719616 ANGLED CLIMBER LARGE (72in DECK)1 62.71 182 2 1.00 0.00 1

CertifiedZZCH794917 SILO CLIMBER (36in DECK)1 70.33 129 1 1.50 0.06 1

CertifiedZZCH831018 RIBBON CLIMBER (72in DECK)1 46.82 120 2 1.50 0.06 1

CertifiedZZCH577019 LEG LIFT 1 6.76 30 1 0.50 0.00 1

CertifiedZZCH597020 OVERHEAD EVENT ACCESS LADDER (36in DECK)

1 25.12 71 1 1.50 0.06 0

CertifiedZZCH696621 10ft ROUNDABOUT HORIZONTAL LADDER1 139.10 298 3 1.00 0.00 1

N/AZZCH659522 6ft ARCH BRIDGE 1 183.35 415 2 1.50 0.00 1

CertifiedZZCH659723 6ft ADVENTURE BRIDGE w/ISO43 CHAIN1 178.54 743 2 3.00 0.00 1

DescriptionConcrete

(Yds3)

TotalWeight

(lbs) Users

Design Number: 350-1743A - Compliance and Technical Data

350-1743

Pre-Consumer

Recycled Content(lbs)

CO2eFootprint

(kgs)InstallHours

Ref.No.

Reference Document: ASTM F1487

UnitASTMStatus

ActivePlay

Events

Post-

Part No. Qty.

Tuesday, May 05, 2020 Page of1 3 Playworld.com

Page 10: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

CertifiedZZCH455624 7in BELL (POST MOUNT) 1 4.61 41 1 0.25 0.00 1

CertifiedZZCH455825 9in BELL (POST MOUNT) 1 6.21 45 1 0.25 0.00 1

CertifiedZZCH984626 CABANA ROOF 1 76.05 390 0 0.50 0.00 0

CertifiedZZCH917727 36in ACCESS STEPPED PLATFORM (DECK TO DECK)

1 217.24 550 2 1.50 0.00 0

N/AZZUN147128 INSTALLER HARDWARE KIT 1 57

CertifiedZZUN991029 SURFACING WARNING LABEL KIT 1 0.05 1 0 0.25 0.00 0

N/AZZUN993030 PIPE SYSTEMS MAINTENANCE KIT W/ AEROSOL

1 90

N/AZZXX067831 LABEL KIT- COMPOSITE STRUCTURE - ASTM1 0.04 TBD 0 0.08 0.00 0

N/AZZXXGNGUID32 GENERAL INSTALLERS GUIDE 1 1

DescriptionConcrete

(Yds3)

TotalWeight

(lbs) Users

Design Number: 350-1743A - Compliance and Technical Data

350-1743

Pre-Consumer

Recycled Content(lbs)

CO2eFootprint

(kgs)InstallHours

Ref.No.

Reference Document: ASTM F1487

UnitASTMStatus

ActivePlay

Events

Post-

Part No. Qty.

468 918 7,476 43 48.08 2.712,816.15 15Totals:

7 Metric Tons413 Kg211 Kg1,267.27 Kg 2.06 m3

Tuesday, May 05, 2020 Page of2 3 Playworld.com

Page 11: 350-1743 Equipment Manufacturer · 350-1743 Pre-Consumer Recycled Content (lbs) CO2e Footprint (kgs) Install Hours Ref. No. Reference Document: ASTM F1487 Unit ASTM Status Active

DescriptionConcrete

(Yds3)

TotalWeight

(lbs) Users

Design Number: 350-1743A - Compliance and Technical Data

350-1743

Pre-Consumer

Recycled Content(lbs)

CO2eFootprint

(kgs)InstallHours

Ref.No.

Reference Document: ASTM F1487

UnitASTMStatus

ActivePlay

Events

Post-

Part No. Qty.

The lay-out for this custom playscape, design number 350-1743A, has been configured to meet the requirements of the ASTM F1487 standard. In addition, each of the above components listed as "Certified" have been tested and are IPEMA certified. Components listed as "Not Applicable" do not fall within the scope of the ASTM F1487 standard and have not been tested. IPEMA certification can be verified on the IPEMA website, www.ipema.org. In the interest of playground safety, IPEMA provides a Third Party Certification Service which validates compliance.

The CO2e (carbon footprint given in Kilograms and Metric Tons) listed above is a measure of the environmental impact this play structure represents from harvesting raw materials to the time it leaves our shipping dock. Playworld Systems nurtures a total corporate culture that is focused on eliminating carbon producing processes and products, reducing our use of precious raw materials, reusing materials whenever possible and recycling materials at every opportunity. Playworld Systems elected to adopt the Publicly Available Specification; PAS 2050 as published by the British Standards Institute and sponsored by Defra and the Carbon Trust. The PAS 2050 has gained international acceptance as a specification that measures the greenhouse gas emissions in services and goods throughout their entire life cycle.

The lay-out was also designed to meet the 2010 Standards published 15-Sep-2010, by the Department of Justice when installed over a properly maintained surfacing material that is in compliance with ASTM F1951 "Accessibility of Surface Systems Under and Around Playground Equipment" as well as ASTM F1292, "Impact Attenuation of Surfacing Materials Within the Use Zone of Playground Equipment", appropriate for the fall height of the structure.

Installation times are based on one experienced installer. A crew of three experienced individuals can perform the installation within the given time, each member working 1/3 of the given hours. [Eg. Installation Time = 30 hours. For a crew of three, each member will work 10 hours on the installation for a total of 30 hours on the project.]

A measurement, in pounds, that qualifies the amount of material that was captured as waste and diverted from landfill during an initial manufacturing process and is being redirected to a separate manufacturing process to become a different product. E.g. 100% of our Aluminum Tubing is made from captured waste material during the manufacturing process of extruded Aluminum products such as rods, flat bars and H-channels.

A measurement, in pounds, that qualifies the amount of material that was once another product that has completed its lifecycle and has been diverted from a landfill as a solid waste through recycling and is now being used in a Playworld Systems' product. E.g. **20% to 40% of the steel in our steel tubing and sheet steel have been diverted from landfills. Automobiles are scrapped and recyclable steel is purchased by the steel mill that produces our raw product.** The amount of Post-Consumer recycled steel fluctuates daily based on the availability of the recycled steel.

ASTM F1487

2010 ADA Standards for Accessible Design

Installation Times

Carbon Footprint

Pre-Consumer Recycle Content

Post-Consumer Recycle Content

Tuesday, May 05, 2020 Page of3 3 Playworld.com