346869 - Brochure, PROSELECT Force Boiler Cast Iron Boilers, BTHQ · 2017-02-28 · OIL FIRED WATER...
Transcript of 346869 - Brochure, PROSELECT Force Boiler Cast Iron Boilers, BTHQ · 2017-02-28 · OIL FIRED WATER...
GAS FIRED WATER
OIL FIRED WATER
GASFIREDSTEAM
Proselect Force Cast Iron boilers are offered exclusively by Ferguson.For the stocking Branch location nearest you please call(888) 334-0004 or WWW.FERGUSONONLINE.COM
BOILERS
Gas-Fired Cast IronWater Boilers
Contact your local associate for details.
• Proselect Force Boilers are offered exclusively by Ferguson
• Hydrolevel® Hydrostat™ – advanced controls with built-in LWCO, outdoor reset option available (not included)
• Reliable cast iron heat exchanger using steel nipples to join sections
• Limited lifetime warranty on heat exchanger, one year manufacturer’s warranty on parts
• 37,000 - 299,000 BTUs in 9 sizes• Built-in draft diverter – fits in low spaces• Industry standard tapping locations, provides
drop-in replacement in most installations• Can be installed on combustible floors• Optional high altitude conversion kit• Hydrolevel® HydroStat™ 3200 combination
high limit/circulator relay control – Built-in LWCO – Outdoor reset available (not included) – Energy-saving thermal targeting software
• Grundfos® 15-58 circulator• Honeywell® 8610 electronic ignition
control & Honeywell gas valves• Automatic vent damper• Roll-out switch, spill switch,
ASME relief valve (30 PSI)• Natural gas build with LP field retrofit kit
available – Models 02,04-06 part number: 105526-01 – Model 03 part number: 105527-01 – Models 07-10 part number: 105528-01
• Trapezoidal legs with nylon glides – permit easy positioning during installation
• Optional high altitude conversion kit
Standard Features
Technical Information
NOTES1. Standard piping/control system is located on right side of boiler2. Specifications and dimensions are subject to change without notice3. Net AHRI water ratings shown are based on a piping and pickup allowance of 1.154. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping, etc.Technical Information
• Hydrolevel® HydroStat™ 3200 combination high limit/circulator relay control
– Built-in LWCO – Outdoor reset available (not included) – Energy-saving thermal targeting software• Grundfos® 15-58 circulator• Honeywell® 8610 electronic ignition control & Honeywell gas valves• Automatic vent damper• Roll-out switch, spill switch, ASME relief valve (30 PSI) • Natural gas build with LP field retrofit kit available – Models 02,04-06 part number: 105526-01 – Model 03 part number: 105527-01 – Models 07-10 part number: 105528-01 • Trapezoidal legs with nylon glides – permit easy positioning during
installation
Additional Standard Features
Model “A”
Dimension“B”
Dimension AFUE%Input Rate
(MBH)
DOE HeatingCapacity(MBH)
Net AHRI (MBH)
Flue Collar
Diameter
Water Content
(Gallons)Approx. Shipping
Weight (lbs.)FORCE02 10-1/2” 28” 82 37 30 26 4 2.4 220FORCE03 11-3/4” 28” 82 62 50 43 4 3.2 270FORCE04 15” 28” 82 96 78 68 5 4.0 320FORCE05 18-1/4” 28” 82 130 106 92 6 4.7 370FORCE06 21-1/2” 28” 82 164 134 117 6 5.5 420FORCE07 24-3/4” 30” 82 198 164 143 7 6.3 470FORCE08 28” 30” 82 232 191 166 7 7.0 520FORCE09 31-1/4” 30” 82 266 218 190 8 7.8 570FORCE10 34-1/2” 30 ” 82 299 244 212 8 8.6 620
NOTES:1. Standard piping/control system is located on right side of boiler2. Specifications and dimensions are subject to change without notice3. Net AHRI water ratings shown are based on a piping and pickup allowance of 1.154. The manufacturer should be consulted before selecting a boiler for installations having
unusual piping and pickup requirements, such as intermittent system operation, extensive piping, etc.
ASM
E
H
1-1/4” Return
Left Side Front Right Side
1-1/4” SupplyVent Damper
CombinationLimit Relief Valve
Temp/Pressure Gauge
Drain Valve
Gas Valve 16”A
32-1/4”
B
3”
16”
Floor Line
E/I Module
39”
Technical Information
• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve
Additional Standard Features
Model
DImensions (inches)
AFUE%Input Rate
(MBH)
DOE HeatingCapacity(MBH)
Net AHRISteam (MBH)
Steam (Sq. Ft.)
Approx. Shipping Weight (lbs.)“A” “B” “C”
Flue Collar
DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690
ASM
E
H
Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.
TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.
BOILERS
BOILERS
Model
Dimensions (Inches) AFUE% Input Rate
(MBH)DOE Heating
Capacity (MBH)Net AHRI
(MBH)Flue Collar Diameter
Water Content
(Gallons)
Approx. Shipping Weight (Pounds)
A B
FORCE02 10-1/2" 28" 82 37 30 24 4 2.4 220
FORCE03 11-3/4" 28" 82 62 50 43 4 3.2 270
FORCE04 15" 28" 82 96 78 68 5 4.0 320
FORCE05 18-1/4" 28" 82 130 106 92 6 4.7 370
FORCE06 21-1/2" 28" 82 164 134 117 6 5.5 420
FORCE07 24-3/4" 30" 82 198 164 143 7 6.3 470
FORCE08 28" 30" 82 232 191 166 7 7.0 520
FORCE09 31-1/4" 30" 82 266 218 190 8 78 570
FORCE10 34-1/2" 30" 82 299 244 212 8 8.6 620
Gas-Fired Cast Iron Steam Boiler
• Natural gas (LP conversion kit available)• Electronic ignition• Built-in draft diverter – fits in low spaces• Cast iron heat exchanger, meets ASME
boiler code and pressure vessel code• Metal section connectors resist chemicals,
increase the life of the boiler• Fully assembled• 10-year limited warranty• Fully packaged• Insulated jacket• Pressure limit• 15 PSI safety valve• Honeywell gas valve• Hydrolevel probe-type LWCO• Steam pressure gauge• Built-in draft diverter• Flame roll out switch• Blocked vent switch• Vent damper• Drain valve
Standard Features
Technical Information
• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve
Additional Standard Features
Model
DImensions (inches)
AFUE%Input Rate
(MBH)
DOE HeatingCapacity(MBH)
Net AHRISteam (MBH)
Steam (Sq. Ft.)
Approx. Shipping Weight (lbs.)“A” “B” “C”
Flue Collar
DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690
ASM
E
H
Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.
TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.
Contact your local associate for details.
Technical Information
Technical Information
• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve
Additional Standard Features
Model
DImensions (inches)
AFUE%Input Rate
(MBH)
DOE HeatingCapacity(MBH)
Net AHRISteam (MBH)
Steam (Sq. Ft.)
Approx. Shipping Weight (lbs.)“A” “B” “C”
Flue Collar
DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690
ASM
E
H
Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.
TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.
Technical Information
• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve
Additional Standard Features
Model
DImensions (inches)
AFUE%Input Rate
(MBH)
DOE HeatingCapacity(MBH)
Net AHRISteam (MBH)
Steam (Sq. Ft.)
Approx. Shipping Weight (lbs.)“A” “B” “C”
Flue Collar
DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690
ASM
E
H
Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.
TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.
The Net AHRI Steam Ratings shown are based on a piping and pickup allowance of 1.333. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
Ratings shown are for installations at sea level and elevations up to 2,000 feet.
BOILERS
BOILERS
Model
Dimensions (inches)
AFUE% Input Rate (MBH)
DOE Heating Capacity (MBH)
Net AHRI Steam (MBH)
Steam(Square Feet)
Approx. Shipping Weight (Pounds)
A B C Flue Collar Diameter
FORCESTEAM03 12-3/4 28" 40-7/16 4 81.9 69 56 42 175 350
FORCESTEAM04 16 28" 40-7/16 5 82.0 103 84 63 263 420
FORCESTEAM05 19-1/4 28" 40-7/16 6 82.0 138 113 85 354 485
FORCESTEAM06 22-1/2 28" 40-7/16 6 82.1 172 142 107 446 555
FORCESTEAM07 25-3/4 30" 40-7/16 7 82.1 207 171 128 533 620
FORCESTEAM08 29 30" 40-7/16 7 82.2 241 199 149 621 690
Model
Dimensions (Inches)
AFUE%
Burner CapacityNet AHRI Ratings (MBH)
Water Content
(Gallons)
Heating Transfer
Surface Area (Square Feet)
Approximate Shipping Weight
(Pounds)A B C GPH MBH
DOE Heating Capacity (MBH)
FORCEOIL084 17 24 5 87 0.60 84 73 63 7.7 13.29 430
FORCEOIL115 17 24 5 87 0.80 115 100 87 7.7 13.29 430
FORCEOIL147 23 24 6 87 1.05 147 129 112 11.08 20.29 545
FORCEOIL189 29 30 6 87 1.35 189 166 144 14.46 27.29 686
High Efficiency Cast Iron Oil-Fired Boiler
• 87% AFUE, ENERGY STAR® certified• 0.6 to 1.35 GPH in four sizes• Chimney vented, optional direct vent
kit available (sizes 147, 189)• Integrated boiler control• 3-pass cast iron heat exchanger• Fully-opening, reversible, cast iron swing door• Return water mixing tube• Cast iron section connectors• Lifetime limited warranty
on heat exchanger• Fully packaged
• Integrated boiler control system• 3450 RPM flame retention Beckett oil burner• Beckett GeniSYS primary control• Return water mixing tube• Grundfos UPS15-58 circlulator• Electronic ignitor 14KV• Clean cut fuel pump• Tridcator• Relief valve• Drain valve• Integrated lifting legs (for level installation)
Standard Features
Contact your local associate for details.
112"NPT SYSTEM RETURN
CONNECTION
19" MIN.BURNER SWING
DOOR CLEARANCE(FULLY OPEN)(SEE NOTE 3)
FRONT SERVICECLEARANCE
(FLUEWAY CLEANING)
DRAIN VALVE
CLEANOUT COVER
SMOKEBOX COLLAR
COLLARDIA.
FLAMEOBSERVATION
PORT
BURNERSWINGDOOR
TEMP/PRESSUREGAUGE
RELIEFVALVE
BECKETT AFGBURNER(SHOWN)
SPANNER BAR W/ADJUSTABLE LEGS
112"NPT SYSTEM
SUPPLYCONNECTION
2138"
3178"
BOILERCONTROL
NOTES: 1. THIS DIMENSION INCREASES AND IS CONTROLLED BY SMOKEPIPE ARRANGEMENT. 2. DRAIN VALVE AND RELIEF VALVE/FITTINGS SHIPPED LOOSE. 3. BOILER SHIPPED WITH STANDARD RIGHT HAND HINGE CONFIGURATION, BUT CAN BE CONVERTED TO LEFT HAND HINGE. APPLY CLEARANCE ACCORDINGLY.
12" MINREAR SERVICE
CLEARANCE(SEE NOTE 1)
1314"
20 "34 5 "3
4
SMOKEBOXPRESURETAPPING
31116"
IMMERSIONWELL
Technical Information
Additional Standard Features
Model
Dimensions (Inches)
AFUE%
Burner Capacity
Net AHRI
Ratings (MBH)
WaterContent(Gal.)
Heating Transfer Surface
Area(Sq. Ft.)
Approximate Shipping Weight (lbs.)GPH MBH
DOE HeatingCapacity(MBH)A B C
FORCEOL084 17 24 5 87 0.60 84 73 63 7.7 13.29 430FORCEOL115 17 24 5 87 0.80 115 100 87 7.7 13.29 430FORCEOL147 23 24 6 87 1.05 147 129 112 11.08 20.29 545FORCEOL189 29 30 6 87 1.35 189 166 144 14.46 27.29 658
ASM
E
H
TheNetAHRIRatingsshownarebasedonapipingandpickupallowanceof1.15.
• Fullypackaged• Integratedboilercontrolsystem• 3450RPMflameretention Beckettoilburner• BeckettGeniSYSprimarycontrol• Returnwatermixingtube• GrundfosUPS15-58circlulator
• Electronicignitor14KV• Cleancutfuelpump• Tridcator• Reliefvalve• Drainvalve• Integratedliftinglegs (forlevelinstallation)
Model
Min. Chimney Requirements Direct Vent SystemRound Inch
Diam.Rectangle(Inches)
Height(Feet)
Kit PartNumber
Vent Connector Diameter (In.)
FORCEOL084 6 8x8 15 N/A N/AFORCEOL115 6 8x8 15 N/A N/AFORCEOL147 6 8x8 15 106401-01 5FORCEOL189 7 8x8 15 106401-01 5
Note:Returnfittingsanddrainvalveshippedloose.
112"NPT SYSTEM RETURN
CONNECTION
19" MIN.BURNER SWING
DOOR CLEARANCE(FULLY OPEN)(SEE NOTE 3)
FRONT SERVICECLEARANCE
(FLUEWAY CLEANING)
DRAIN VALVE
CLEANOUT COVER
SMOKEBOX COLLAR
COLLARDIA.
FLAMEOBSERVATION
PORT
BURNERSWINGDOOR
TEMP/PRESSUREGAUGE
RELIEFVALVE
BECKETT AFGBURNER(SHOWN)
SPANNER BAR W/ADJUSTABLE LEGS
112"NPT SYSTEM
SUPPLYCONNECTION
2138"
3178"
BOILERCONTROL
NOTES: 1. THIS DIMENSION INCREASES AND IS CONTROLLED BY SMOKEPIPE ARRANGEMENT. 2. DRAIN VALVE AND RELIEF VALVE/FITTINGS SHIPPED LOOSE. 3. BOILER SHIPPED WITH STANDARD RIGHT HAND HINGE CONFIGURATION, BUT CAN BE CONVERTED TO LEFT HAND HINGE. APPLY CLEARANCE ACCORDINGLY.
12" MINREAR SERVICE
CLEARANCE(SEE NOTE 1)
1314"
20 "34 5 "3
4
SMOKEBOXPRESURETAPPING
31116"
IMMERSIONWELL
Technical Information
Additional Standard Features
Model
Dimensions (Inches)
AFUE%
Burner Capacity
Net AHRI
Ratings (MBH)
WaterContent(Gal.)
Heating Transfer Surface
Area(Sq. Ft.)
Approximate Shipping Weight (lbs.)GPH MBH
DOE HeatingCapacity(MBH)A B C
FORCEOL084 17 24 5 87 0.60 84 73 63 7.7 13.29 430FORCEOL115 17 24 5 87 0.80 115 100 87 7.7 13.29 430FORCEOL147 23 24 6 87 1.05 147 129 112 11.08 20.29 545FORCEOL189 29 30 6 87 1.35 189 166 144 14.46 27.29 658
ASM
E
H
TheNetAHRIRatingsshownarebasedonapipingandpickupallowanceof1.15.
• Fullypackaged• Integratedboilercontrolsystem• 3450RPMflameretention Beckettoilburner• BeckettGeniSYSprimarycontrol• Returnwatermixingtube• GrundfosUPS15-58circlulator
• Electronicignitor14KV• Cleancutfuelpump• Tridcator• Reliefvalve• Drainvalve• Integratedliftinglegs (forlevelinstallation)
Model
Min. Chimney Requirements Direct Vent SystemRound Inch
Diam.Rectangle(Inches)
Height(Feet)
Kit PartNumber
Vent Connector Diameter (In.)
FORCEOL084 6 8x8 15 N/A N/AFORCEOL115 6 8x8 15 N/A N/AFORCEOL147 6 8x8 15 106401-01 5FORCEOL189 7 8x8 15 106401-01 5
Note:Returnfittingsanddrainvalveshippedloose.
Technical Information
112"NPT SYSTEM RETURN
CONNECTION
19" MIN.BURNER SWING
DOOR CLEARANCE(FULLY OPEN)(SEE NOTE 3)
FRONT SERVICECLEARANCE
(FLUEWAY CLEANING)
DRAIN VALVE
CLEANOUT COVER
SMOKEBOX COLLAR
COLLARDIA.
FLAMEOBSERVATION
PORT
BURNERSWINGDOOR
TEMP/PRESSUREGAUGE
RELIEFVALVE
BECKETT AFGBURNER(SHOWN)
SPANNER BAR W/ADJUSTABLE LEGS
112"NPT SYSTEM
SUPPLYCONNECTION
2138"
3178"
BOILERCONTROL
NOTES: 1. THIS DIMENSION INCREASES AND IS CONTROLLED BY SMOKEPIPE ARRANGEMENT. 2. DRAIN VALVE AND RELIEF VALVE/FITTINGS SHIPPED LOOSE. 3. BOILER SHIPPED WITH STANDARD RIGHT HAND HINGE CONFIGURATION, BUT CAN BE CONVERTED TO LEFT HAND HINGE. APPLY CLEARANCE ACCORDINGLY.
12" MINREAR SERVICE
CLEARANCE(SEE NOTE 1)
1314"
20 "34 5 "3
4
SMOKEBOXPRESURETAPPING
31116"
IMMERSIONWELL
Technical Information
Additional Standard Features
Model
Dimensions (Inches)
AFUE%
Burner Capacity
Net AHRI
Ratings (MBH)
WaterContent(Gal.)
Heating Transfer Surface
Area(Sq. Ft.)
Approximate Shipping Weight (lbs.)GPH MBH
DOE HeatingCapacity(MBH)A B C
FORCEOL084 17 24 5 87 0.60 84 73 63 7.7 13.29 430FORCEOL115 17 24 5 87 0.80 115 100 87 7.7 13.29 430FORCEOL147 23 24 6 87 1.05 147 129 112 11.08 20.29 545FORCEOL189 29 30 6 87 1.35 189 166 144 14.46 27.29 658
ASM
E
H
TheNetAHRIRatingsshownarebasedonapipingandpickupallowanceof1.15.
• Fullypackaged• Integratedboilercontrolsystem• 3450RPMflameretention Beckettoilburner• BeckettGeniSYSprimarycontrol• Returnwatermixingtube• GrundfosUPS15-58circlulator
• Electronicignitor14KV• Cleancutfuelpump• Tridcator• Reliefvalve• Drainvalve• Integratedliftinglegs (forlevelinstallation)
Model
Min. Chimney Requirements Direct Vent SystemRound Inch
Diam.Rectangle(Inches)
Height(Feet)
Kit PartNumber
Vent Connector Diameter (In.)
FORCEOL084 6 8x8 15 N/A N/AFORCEOL115 6 8x8 15 N/A N/AFORCEOL147 6 8x8 15 106401-01 5FORCEOL189 7 8x8 15 106401-01 5
Note:Returnfittingsanddrainvalveshippedloose.NOTE Return fittings and drain valve shipped loose. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping, etc.
The Net AHRI Ratings shown are based on a piping and pickup allowance of 1.15.
BOILERS
Model
Min. Chimney Requirements Direct Vent Required Accessories
Round Rectangle Height Kit Part Beckett NX Vent Connector
FORCEOIL084 6 8 x 8 15 N/A N/A N/A
FORCEOIL115 6 8 x 8 15 N/A N/A N/A
FORCEOIL147 6 8 x 8 15 106401-01 106109-03 5*
FORCEOIL189 7 8 x 8 15 106401-01 103369-01 5*
*Choose appropriate flex oil vent pipe length (all have 5 inch diameter): 100211-02 (5 ft.), 100212-02 (10 ft.), 100213-02 (15 ft.), 100214-02 (20 ft.)
©2017 Ferguson Enterprises, Inc. 0217 346869