GAS FIRED WATER OIL FIRED WATER GAS FIRED STEAM Proselect Force Cast Iron boilers are offered exclusively by Ferguson. For the stocking Branch location nearest you please call (888) 334-0004 or WWW.FERGUSONONLINE.COM BOILERS

Transcript of 346869 - Brochure, PROSELECT Force Boiler Cast Iron Boilers, BTHQ · 2017-02-28 · OIL FIRED WATER...

Page 1: 346869 - Brochure, PROSELECT Force Boiler Cast Iron Boilers, BTHQ · 2017-02-28 · OIL FIRED WATER GAS FIRED STEAM ... – Energy-saving thermal targeting software ... Standard piping/control

GAS FIRED WATER

OIL FIRED WATER

GASFIREDSTEAM

Proselect Force Cast Iron boilers are offered exclusively by Ferguson.For the stocking Branch location nearest you please call(888) 334-0004 or WWW.FERGUSONONLINE.COM

BOILERS

Page 2: 346869 - Brochure, PROSELECT Force Boiler Cast Iron Boilers, BTHQ · 2017-02-28 · OIL FIRED WATER GAS FIRED STEAM ... – Energy-saving thermal targeting software ... Standard piping/control

Gas-Fired Cast IronWater Boilers

Contact your local associate for details.

• Proselect Force Boilers are offered exclusively by Ferguson

• Hydrolevel® Hydrostat™ – advanced controls with built-in LWCO, outdoor reset option available (not included)

• Reliable cast iron heat exchanger using steel nipples to join sections

• Limited lifetime warranty on heat exchanger, one year manufacturer’s warranty on parts

• 37,000 - 299,000 BTUs in 9 sizes• Built-in draft diverter – fits in low spaces• Industry standard tapping locations, provides

drop-in replacement in most installations• Can be installed on combustible floors• Optional high altitude conversion kit• Hydrolevel® HydroStat™ 3200 combination

high limit/circulator relay control – Built-in LWCO – Outdoor reset available (not included) – Energy-saving thermal targeting software

• Grundfos® 15-58 circulator• Honeywell® 8610 electronic ignition

control & Honeywell gas valves• Automatic vent damper• Roll-out switch, spill switch,

ASME relief valve (30 PSI)• Natural gas build with LP field retrofit kit

available – Models 02,04-06 part number: 105526-01 – Model 03 part number: 105527-01 – Models 07-10 part number: 105528-01

• Trapezoidal legs with nylon glides – permit easy positioning during installation

• Optional high altitude conversion kit

Standard Features

Technical Information

NOTES1. Standard piping/control system is located on right side of boiler2. Specifications and dimensions are subject to change without notice3. Net AHRI water ratings shown are based on a piping and pickup allowance of 1.154. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping, etc.Technical Information

• Hydrolevel® HydroStat™ 3200 combination high limit/circulator relay control

– Built-in LWCO – Outdoor reset available (not included) – Energy-saving thermal targeting software• Grundfos® 15-58 circulator• Honeywell® 8610 electronic ignition control & Honeywell gas valves• Automatic vent damper• Roll-out switch, spill switch, ASME relief valve (30 PSI) • Natural gas build with LP field retrofit kit available – Models 02,04-06 part number: 105526-01 – Model 03 part number: 105527-01 – Models 07-10 part number: 105528-01 • Trapezoidal legs with nylon glides – permit easy positioning during

installation

Additional Standard Features

Model “A”

Dimension“B”

Dimension AFUE%Input Rate

(MBH)

DOE HeatingCapacity(MBH)

Net AHRI (MBH)

Flue Collar

Diameter

Water Content

(Gallons)Approx. Shipping

Weight (lbs.)FORCE02 10-1/2” 28” 82 37 30 26 4 2.4 220FORCE03 11-3/4” 28” 82 62 50 43 4 3.2 270FORCE04 15” 28” 82 96 78 68 5 4.0 320FORCE05 18-1/4” 28” 82 130 106 92 6 4.7 370FORCE06 21-1/2” 28” 82 164 134 117 6 5.5 420FORCE07 24-3/4” 30” 82 198 164 143 7 6.3 470FORCE08 28” 30” 82 232 191 166 7 7.0 520FORCE09 31-1/4” 30” 82 266 218 190 8 7.8 570FORCE10 34-1/2” 30 ” 82 299 244 212 8 8.6 620

NOTES:1. Standard piping/control system is located on right side of boiler2. Specifications and dimensions are subject to change without notice3. Net AHRI water ratings shown are based on a piping and pickup allowance of 1.154. The manufacturer should be consulted before selecting a boiler for installations having

unusual piping and pickup requirements, such as intermittent system operation, extensive piping, etc.

ASM

E

H

1-1/4” Return

Left Side Front Right Side

1-1/4” SupplyVent Damper

CombinationLimit Relief Valve

Temp/Pressure Gauge

Drain Valve

Gas Valve 16”A

32-1/4”

B

3”

16”

Floor Line

E/I Module

39”

Technical Information

• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve

Additional Standard Features

Model

DImensions (inches)

AFUE%Input Rate

(MBH)

DOE HeatingCapacity(MBH)

Net AHRISteam (MBH)

Steam (Sq. Ft.)

Approx. Shipping Weight (lbs.)“A” “B” “C”

Flue Collar

DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690

ASM

E

H

Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.

TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.

BOILERS

BOILERS

Model

Dimensions (Inches) AFUE% Input Rate

(MBH)DOE Heating

Capacity (MBH)Net AHRI

(MBH)Flue Collar Diameter

Water Content

(Gallons)

Approx. Shipping Weight (Pounds)

A B

FORCE02 10-1/2" 28" 82 37 30 24 4 2.4 220

FORCE03 11-3/4" 28" 82 62 50 43 4 3.2 270

FORCE04 15" 28" 82 96 78 68 5 4.0 320

FORCE05 18-1/4" 28" 82 130 106 92 6 4.7 370

FORCE06 21-1/2" 28" 82 164 134 117 6 5.5 420

FORCE07 24-3/4" 30" 82 198 164 143 7 6.3 470

FORCE08 28" 30" 82 232 191 166 7 7.0 520

FORCE09 31-1/4" 30" 82 266 218 190 8 78 570

FORCE10 34-1/2" 30" 82 299 244 212 8 8.6 620

Page 3: 346869 - Brochure, PROSELECT Force Boiler Cast Iron Boilers, BTHQ · 2017-02-28 · OIL FIRED WATER GAS FIRED STEAM ... – Energy-saving thermal targeting software ... Standard piping/control

Gas-Fired Cast Iron Steam Boiler

• Natural gas (LP conversion kit available)• Electronic ignition• Built-in draft diverter – fits in low spaces• Cast iron heat exchanger, meets ASME

boiler code and pressure vessel code• Metal section connectors resist chemicals,

increase the life of the boiler• Fully assembled• 10-year limited warranty• Fully packaged• Insulated jacket• Pressure limit• 15 PSI safety valve• Honeywell gas valve• Hydrolevel probe-type LWCO• Steam pressure gauge• Built-in draft diverter• Flame roll out switch• Blocked vent switch• Vent damper• Drain valve

Standard Features

Technical Information

• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve

Additional Standard Features

Model

DImensions (inches)

AFUE%Input Rate

(MBH)

DOE HeatingCapacity(MBH)

Net AHRISteam (MBH)

Steam (Sq. Ft.)

Approx. Shipping Weight (lbs.)“A” “B” “C”

Flue Collar

DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690

ASM

E

H

Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.

TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.

Contact your local associate for details.

Technical Information

Technical Information

• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve

Additional Standard Features

Model

DImensions (inches)

AFUE%Input Rate

(MBH)

DOE HeatingCapacity(MBH)

Net AHRISteam (MBH)

Steam (Sq. Ft.)

Approx. Shipping Weight (lbs.)“A” “B” “C”

Flue Collar

DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690

ASM

E

H

Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.

TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.

Technical Information

• Fullypackaged• Insulatedjacket• Pressurelimit• 15PSIsafetyvalve• Honeywellgasvalve• Hydrolevelprobe-typeLWCO• Steampressuregauge• Built-indraftdiverter• Flamerolloutswitch• Blockedventswitch• Ventdamper• Drainvalve

Additional Standard Features

Model

DImensions (inches)

AFUE%Input Rate

(MBH)

DOE HeatingCapacity(MBH)

Net AHRISteam (MBH)

Steam (Sq. Ft.)

Approx. Shipping Weight (lbs.)“A” “B” “C”

Flue Collar

DiameterFORCESTM03 12-3/4 28” 40-7/16 4 81.9 69 56 42 175 350FORCESTM04 16 28” 40-7/16 5 82.0 103 84 63 263 420FORCESTM05 19-1/4 28” 40-7/16 6 82.0 138 113 85 354 485FORCESTM06 22-1/2 28” 40-7/16 6 82.1 172 142 107 446 555FORCESTM07 25-3/4 30” 40-7/16 7 82.1 207 171 128 533 620FORCESTM08 29 30” 40-7/16 7 82.2 241 199 149 621 690

ASM

E

H

Ratingsshownareforinstallationsatsealevelandelevationsupto2,000feet.

TheNetAHRISteamRatingsshownarebasedonapipingandpickupallowanceof1.333.Themanufacturershouldbeconsultedbeforeselectingaboilerforinstallationshavingunusualpipingandpickuprequirements,suchasintermittentsystemoperation,extensivepipingsystems,etc.

The Net AHRI Steam Ratings shown are based on a piping and pickup allowance of 1.333. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.

Ratings shown are for installations at sea level and elevations up to 2,000 feet.

BOILERS

BOILERS

Model

Dimensions (inches)

AFUE% Input Rate (MBH)

DOE Heating Capacity (MBH)

Net AHRI Steam (MBH)

Steam(Square Feet)

Approx. Shipping Weight (Pounds)

A B C Flue Collar Diameter

FORCESTEAM03 12-3/4 28" 40-7/16 4 81.9 69 56 42 175 350

FORCESTEAM04 16 28" 40-7/16 5 82.0 103 84 63 263 420

FORCESTEAM05 19-1/4 28" 40-7/16 6 82.0 138 113 85 354 485

FORCESTEAM06 22-1/2 28" 40-7/16 6 82.1 172 142 107 446 555

FORCESTEAM07 25-3/4 30" 40-7/16 7 82.1 207 171 128 533 620

FORCESTEAM08 29 30" 40-7/16 7 82.2 241 199 149 621 690

Page 4: 346869 - Brochure, PROSELECT Force Boiler Cast Iron Boilers, BTHQ · 2017-02-28 · OIL FIRED WATER GAS FIRED STEAM ... – Energy-saving thermal targeting software ... Standard piping/control

Model

Dimensions (Inches)

AFUE%

Burner CapacityNet AHRI Ratings (MBH)

Water Content

(Gallons)

Heating Transfer

Surface Area (Square Feet)

Approximate Shipping Weight

(Pounds)A B C GPH MBH

DOE Heating Capacity (MBH)

FORCEOIL084 17 24 5 87 0.60 84 73 63 7.7 13.29 430

FORCEOIL115 17 24 5 87 0.80 115 100 87 7.7 13.29 430

FORCEOIL147 23 24 6 87 1.05 147 129 112 11.08 20.29 545

FORCEOIL189 29 30 6 87 1.35 189 166 144 14.46 27.29 686

High Efficiency Cast Iron Oil-Fired Boiler

• 87% AFUE, ENERGY STAR® certified• 0.6 to 1.35 GPH in four sizes• Chimney vented, optional direct vent

kit available (sizes 147, 189)• Integrated boiler control• 3-pass cast iron heat exchanger• Fully-opening, reversible, cast iron swing door• Return water mixing tube• Cast iron section connectors• Lifetime limited warranty

on heat exchanger• Fully packaged

• Integrated boiler control system• 3450 RPM flame retention Beckett oil burner• Beckett GeniSYS primary control• Return water mixing tube• Grundfos UPS15-58 circlulator• Electronic ignitor 14KV• Clean cut fuel pump• Tridcator• Relief valve• Drain valve• Integrated lifting legs (for level installation)

Standard Features

Contact your local associate for details.

112"NPT SYSTEM RETURN

CONNECTION

19" MIN.BURNER SWING

DOOR CLEARANCE(FULLY OPEN)(SEE NOTE 3)

FRONT SERVICECLEARANCE

(FLUEWAY CLEANING)

DRAIN VALVE

CLEANOUT COVER

SMOKEBOX COLLAR

COLLARDIA.

FLAMEOBSERVATION

PORT

BURNERSWINGDOOR

TEMP/PRESSUREGAUGE

RELIEFVALVE

BECKETT AFGBURNER(SHOWN)

SPANNER BAR W/ADJUSTABLE LEGS

112"NPT SYSTEM

SUPPLYCONNECTION

2138"

3178"

BOILERCONTROL

NOTES: 1. THIS DIMENSION INCREASES AND IS CONTROLLED BY SMOKEPIPE ARRANGEMENT. 2. DRAIN VALVE AND RELIEF VALVE/FITTINGS SHIPPED LOOSE. 3. BOILER SHIPPED WITH STANDARD RIGHT HAND HINGE CONFIGURATION, BUT CAN BE CONVERTED TO LEFT HAND HINGE. APPLY CLEARANCE ACCORDINGLY.

12" MINREAR SERVICE

CLEARANCE(SEE NOTE 1)

1314"

20 "34 5 "3

4

SMOKEBOXPRESURETAPPING

31116"

IMMERSIONWELL

Technical Information

Additional Standard Features

Model

Dimensions (Inches)

AFUE%

Burner Capacity

Net AHRI

Ratings (MBH)

WaterContent(Gal.)

Heating Transfer Surface

Area(Sq. Ft.)

Approximate Shipping Weight (lbs.)GPH MBH

DOE HeatingCapacity(MBH)A B C

FORCEOL084 17 24 5 87 0.60 84 73 63 7.7 13.29 430FORCEOL115 17 24 5 87 0.80 115 100 87 7.7 13.29 430FORCEOL147 23 24 6 87 1.05 147 129 112 11.08 20.29 545FORCEOL189 29 30 6 87 1.35 189 166 144 14.46 27.29 658

ASM

E

H

TheNetAHRIRatingsshownarebasedonapipingandpickupallowanceof1.15.

• Fullypackaged• Integratedboilercontrolsystem• 3450RPMflameretention Beckettoilburner• BeckettGeniSYSprimarycontrol• Returnwatermixingtube• GrundfosUPS15-58circlulator

• Electronicignitor14KV• Cleancutfuelpump• Tridcator• Reliefvalve• Drainvalve• Integratedliftinglegs (forlevelinstallation)

Model

Min. Chimney Requirements Direct Vent SystemRound Inch

Diam.Rectangle(Inches)

Height(Feet)

Kit PartNumber

Vent Connector Diameter (In.)

FORCEOL084 6 8x8 15 N/A N/AFORCEOL115 6 8x8 15 N/A N/AFORCEOL147 6 8x8 15 106401-01 5FORCEOL189 7 8x8 15 106401-01 5

Note:Returnfittingsanddrainvalveshippedloose.

112"NPT SYSTEM RETURN

CONNECTION

19" MIN.BURNER SWING

DOOR CLEARANCE(FULLY OPEN)(SEE NOTE 3)

FRONT SERVICECLEARANCE

(FLUEWAY CLEANING)

DRAIN VALVE

CLEANOUT COVER

SMOKEBOX COLLAR

COLLARDIA.

FLAMEOBSERVATION

PORT

BURNERSWINGDOOR

TEMP/PRESSUREGAUGE

RELIEFVALVE

BECKETT AFGBURNER(SHOWN)

SPANNER BAR W/ADJUSTABLE LEGS

112"NPT SYSTEM

SUPPLYCONNECTION

2138"

3178"

BOILERCONTROL

NOTES: 1. THIS DIMENSION INCREASES AND IS CONTROLLED BY SMOKEPIPE ARRANGEMENT. 2. DRAIN VALVE AND RELIEF VALVE/FITTINGS SHIPPED LOOSE. 3. BOILER SHIPPED WITH STANDARD RIGHT HAND HINGE CONFIGURATION, BUT CAN BE CONVERTED TO LEFT HAND HINGE. APPLY CLEARANCE ACCORDINGLY.

12" MINREAR SERVICE

CLEARANCE(SEE NOTE 1)

1314"

20 "34 5 "3

4

SMOKEBOXPRESURETAPPING

31116"

IMMERSIONWELL

Technical Information

Additional Standard Features

Model

Dimensions (Inches)

AFUE%

Burner Capacity

Net AHRI

Ratings (MBH)

WaterContent(Gal.)

Heating Transfer Surface

Area(Sq. Ft.)

Approximate Shipping Weight (lbs.)GPH MBH

DOE HeatingCapacity(MBH)A B C

FORCEOL084 17 24 5 87 0.60 84 73 63 7.7 13.29 430FORCEOL115 17 24 5 87 0.80 115 100 87 7.7 13.29 430FORCEOL147 23 24 6 87 1.05 147 129 112 11.08 20.29 545FORCEOL189 29 30 6 87 1.35 189 166 144 14.46 27.29 658

ASM

E

H

TheNetAHRIRatingsshownarebasedonapipingandpickupallowanceof1.15.

• Fullypackaged• Integratedboilercontrolsystem• 3450RPMflameretention Beckettoilburner• BeckettGeniSYSprimarycontrol• Returnwatermixingtube• GrundfosUPS15-58circlulator

• Electronicignitor14KV• Cleancutfuelpump• Tridcator• Reliefvalve• Drainvalve• Integratedliftinglegs (forlevelinstallation)

Model

Min. Chimney Requirements Direct Vent SystemRound Inch

Diam.Rectangle(Inches)

Height(Feet)

Kit PartNumber

Vent Connector Diameter (In.)

FORCEOL084 6 8x8 15 N/A N/AFORCEOL115 6 8x8 15 N/A N/AFORCEOL147 6 8x8 15 106401-01 5FORCEOL189 7 8x8 15 106401-01 5

Note:Returnfittingsanddrainvalveshippedloose.

Technical Information

112"NPT SYSTEM RETURN

CONNECTION

19" MIN.BURNER SWING

DOOR CLEARANCE(FULLY OPEN)(SEE NOTE 3)

FRONT SERVICECLEARANCE

(FLUEWAY CLEANING)

DRAIN VALVE

CLEANOUT COVER

SMOKEBOX COLLAR

COLLARDIA.

FLAMEOBSERVATION

PORT

BURNERSWINGDOOR

TEMP/PRESSUREGAUGE

RELIEFVALVE

BECKETT AFGBURNER(SHOWN)

SPANNER BAR W/ADJUSTABLE LEGS

112"NPT SYSTEM

SUPPLYCONNECTION

2138"

3178"

BOILERCONTROL

NOTES: 1. THIS DIMENSION INCREASES AND IS CONTROLLED BY SMOKEPIPE ARRANGEMENT. 2. DRAIN VALVE AND RELIEF VALVE/FITTINGS SHIPPED LOOSE. 3. BOILER SHIPPED WITH STANDARD RIGHT HAND HINGE CONFIGURATION, BUT CAN BE CONVERTED TO LEFT HAND HINGE. APPLY CLEARANCE ACCORDINGLY.

12" MINREAR SERVICE

CLEARANCE(SEE NOTE 1)

1314"

20 "34 5 "3

4

SMOKEBOXPRESURETAPPING

31116"

IMMERSIONWELL

Technical Information

Additional Standard Features

Model

Dimensions (Inches)

AFUE%

Burner Capacity

Net AHRI

Ratings (MBH)

WaterContent(Gal.)

Heating Transfer Surface

Area(Sq. Ft.)

Approximate Shipping Weight (lbs.)GPH MBH

DOE HeatingCapacity(MBH)A B C

FORCEOL084 17 24 5 87 0.60 84 73 63 7.7 13.29 430FORCEOL115 17 24 5 87 0.80 115 100 87 7.7 13.29 430FORCEOL147 23 24 6 87 1.05 147 129 112 11.08 20.29 545FORCEOL189 29 30 6 87 1.35 189 166 144 14.46 27.29 658

ASM

E

H

TheNetAHRIRatingsshownarebasedonapipingandpickupallowanceof1.15.

• Fullypackaged• Integratedboilercontrolsystem• 3450RPMflameretention Beckettoilburner• BeckettGeniSYSprimarycontrol• Returnwatermixingtube• GrundfosUPS15-58circlulator

• Electronicignitor14KV• Cleancutfuelpump• Tridcator• Reliefvalve• Drainvalve• Integratedliftinglegs (forlevelinstallation)

Model

Min. Chimney Requirements Direct Vent SystemRound Inch

Diam.Rectangle(Inches)

Height(Feet)

Kit PartNumber

Vent Connector Diameter (In.)

FORCEOL084 6 8x8 15 N/A N/AFORCEOL115 6 8x8 15 N/A N/AFORCEOL147 6 8x8 15 106401-01 5FORCEOL189 7 8x8 15 106401-01 5

Note:Returnfittingsanddrainvalveshippedloose.NOTE Return fittings and drain valve shipped loose. The manufacturer should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping, etc.

The Net AHRI Ratings shown are based on a piping and pickup allowance of 1.15.

BOILERS

Model

Min. Chimney Requirements Direct Vent Required Accessories

Round Rectangle Height Kit Part Beckett NX Vent Connector

FORCEOIL084 6 8 x 8 15 N/A N/A N/A

FORCEOIL115 6 8 x 8 15 N/A N/A N/A

FORCEOIL147 6 8 x 8 15 106401-01 106109-03 5*

FORCEOIL189 7 8 x 8 15 106401-01 103369-01 5*

*Choose appropriate flex oil vent pipe length (all have 5 inch diameter): 100211-02 (5 ft.), 100212-02 (10 ft.), 100213-02 (15 ft.), 100214-02 (20 ft.)