2002 IS Catalog 138 Pepperl+Fuchs ® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607 E-mail: [email protected] • www.am.pepperl-fuchs.com Page Introduction ............................................................................................................................. 139 Loop-Powered Isolators KFD0-CS-1.50 (Current repeater / driver / isolator / single-channel) .................................................. 140 KFD0-CS-2.50 (Current repeater / driver / isolator / dual-channel) ..................................................... 141 KFD0-CC-1 (Current converter / single channel / isolator) .................................................................. 142 KFD0-VC-1.50m (Voltage to current converter / single-channel / isolator) ......................................... 143 KFD0-VC-1.10 (Voltage to current converter / single-channel / isolator) ............................................ 144 KFD0-TT-1 (Thermocouple / mV input / single-channel / isolator) ...................................................... 145 KFD0-TR-1 (RTD input / single-channel / isolator) .............................................................................. 146 Analog Isolators KFDX-DCI (DC current input / current/voltage output / isolator) ......................................................... 147 KFDX-DCV (DC voltage input / current/voltage output / isolator) ....................................................... 148 KFD2-CR-1.300 (2- or 3-wire transmitter input / 4-20 mA current output / isolator) .......................... 149 KFD2-CD-1.32 (Current/voltage driver / current output / isolator) ...................................................... 150 KFD2-CR4-1.20 (Single input / dual output transmitter / repeater / isolator) ...................................... 151 KFD2-STC4-1.20 (HART transmitter power supply / isolator) ............................................................. 152 KFDX-RTD (RTD input / current/voltage output / isolator) .................................................................. 153 KFDX-TC (Thermocouple input / isolator) ........................................................................................... 154 KFD2-UT-1 (Universal temperature input / isolator) ............................................................................. 155 KFD2-UT-1-1 (Universal temperature input / isolator) ......................................................................... 156 KFDX-AC (AC current/voltage input / current/voltage output / isolator) ............................................. 157 KFDX-HZ (Frequency input / current/voltage output / isolator) .......................................................... 158 KFA5-DWB-1.D (Rotational speed limit alarm) .................................................................................... 159 KFA6-DWB-1.D (Rotational speed limit alarm) .................................................................................... 160 KFD2-DWB-1.D (Rotational speed limit alarm) ................................................................................... 161 KFU8-UFC-1 (Universal frequency converter) ..................................................................................... 162 KFD2-UFC-1.D (Universal frequency converter with display) .............................................................. 163 KFD2-UFC-1 (Universal frequency converter / isolator) ...................................................................... 164 KFU8-UFC-1.D (Universal frequency converter / isolator with display) ............................................... 165 Limit Alarm Isolators KFDA-DCI (DC current input / 2 Form C contact outputs / isolator) ................................................... 166 KFDA-DCV (DC voltage input / 2 Form C contact outputs / isolator) .................................................. 167 KFD2-GS-1.2W (DC current/voltage input / 2 Form C contact outputs / isolator) .............................. 168 KFD2-CRG-1.D (Transmitter power supply / isolator) ......................................................................... 169 KFU8-CRG-1.D (Transmitter power supply / isolator) ......................................................................... 170 KFDA-TC (Thermocouple input / 2 Form C contact outputs / isolator) ............................................... 171 KFDA-RTD (RTD input / 2 Form C contact outputs / isolator) ............................................................ 172 KFDA-GU-1 (Universal input / 2 Form C contact outputs / PC interface / isolator) ............................ 173

Transcript of 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002...

Page 1: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

2002 IS Catalog

138 Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Page

Introduction ............................................................................................................................. 139Loop-Powered Isolators

KFD0-CS-1.50 (Current repeater / driver / isolator / single-channel) .................................................. 140KFD0-CS-2.50 (Current repeater / driver / isolator / dual-channel) ..................................................... 141KFD0-CC-1 (Current converter / single channel / isolator) .................................................................. 142KFD0-VC-1.50m (Voltage to current converter / single-channel / isolator) ......................................... 143KFD0-VC-1.10 (Voltage to current converter / single-channel / isolator) ............................................ 144KFD0-TT-1 (Thermocouple / mV input / single-channel / isolator) ...................................................... 145KFD0-TR-1 (RTD input / single-channel / isolator) .............................................................................. 146

Analog IsolatorsKFDX-DCI (DC current input / current/voltage output / isolator) ......................................................... 147KFDX-DCV (DC voltage input / current/voltage output / isolator) ....................................................... 148KFD2-CR-1.300 (2- or 3-wire transmitter input / 4-20 mA current output / isolator) .......................... 149KFD2-CD-1.32 (Current/voltage driver / current output / isolator) ...................................................... 150KFD2-CR4-1.20 (Single input / dual output transmitter / repeater / isolator) ...................................... 151KFD2-STC4-1.20 (HART transmitter power supply / isolator) ............................................................. 152KFDX-RTD (RTD input / current/voltage output / isolator) .................................................................. 153KFDX-TC (Thermocouple input / isolator) ........................................................................................... 154KFD2-UT-1 (Universal temperature input / isolator) ............................................................................. 155KFD2-UT-1-1 (Universal temperature input / isolator) ......................................................................... 156KFDX-AC (AC current/voltage input / current/voltage output / isolator) ............................................. 157KFDX-HZ (Frequency input / current/voltage output / isolator) .......................................................... 158KFA5-DWB-1.D (Rotational speed limit alarm) .................................................................................... 159KFA6-DWB-1.D (Rotational speed limit alarm) .................................................................................... 160KFD2-DWB-1.D (Rotational speed limit alarm) ................................................................................... 161KFU8-UFC-1 (Universal frequency converter) ..................................................................................... 162KFD2-UFC-1.D (Universal frequency converter with display) .............................................................. 163KFD2-UFC-1 (Universal frequency converter / isolator) ...................................................................... 164KFU8-UFC-1.D (Universal frequency converter / isolator with display) ............................................... 165

Limit Alarm IsolatorsKFDA-DCI (DC current input / 2 Form C contact outputs / isolator) ................................................... 166KFDA-DCV (DC voltage input / 2 Form C contact outputs / isolator) .................................................. 167KFD2-GS-1.2W (DC current/voltage input / 2 Form C contact outputs / isolator) .............................. 168KFD2-CRG-1.D (Transmitter power supply / isolator) ......................................................................... 169KFU8-CRG-1.D (Transmitter power supply / isolator) ......................................................................... 170KFDA-TC (Thermocouple input / 2 Form C contact outputs / isolator) ............................................... 171KFDA-RTD (RTD input / 2 Form C contact outputs / isolator) ............................................................ 172KFDA-GU-1 (Universal input / 2 Form C contact outputs / PC interface / isolator) ............................ 173

Page 2: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

2002 IS Catalog

139Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

With the variety of process control systems available, it is often necessary to convert an input signal intoa format that the control system will accept. Signal conditioners take signals from an assortment of fieldinstruments such as thermocouples and RTDs, and convert those signals into any of several standardinstrument signals (1-5 V, 4-20 mA, etc.) while providing isolations.

Signal conditioners are also beneficial to the accurate transfer of these signals and the elimination ofground loops.

Pepperl+Fuchs signal conditioners utilize the latest technology, offering unparalleled protection againstground loops while maintaining optimum signal accuracy and complete isolation. There are three basictypes of KF signal conditioners:

Loop Powered Repeaters/Isolators: Loop powered repeaters do not require a separatepower supply. Available in single and dual channel models, these transformer isolatedsignal conditioners transfer analog DC signals with each channel working as a DC isolatorproviding 2,500 VDC isolation between the input and output.

Analog Isolators: These units require a separate power supply and provide signalconditioning and 3-way isolation to various input signals.

Limit Alarms: This class of signal conditioners provides two Form C relay outputs withadjustable high and low switchpoints and selectable control safe and normal operation.They also require a separate power supply and provide 3-way isolation.

The latter two categories are fully field-configurable and provide 1,800 VDC isolation separating input,output and power supply. Input and output ranges, modes of operation, switchpoints, etc., can beprogrammed in the field via DIP switches on the side of the housing. Some models also offer a PCinterface. Input, zero, and span are adjustable by potentiometer to 50% for all input ranges. The wide-ranging capabilities and field-configurable settings allow for numerous options in a diverse range ofapplications.

All P+F analog isolators and limit alarms also contain the ASIC chip for increased reliability. ASIC (Appli-cation Specific Integrated Circuitry) substantially reduces failures by virtually eliminating discrete com-ponents and their solder joints where most faults occur. Printed circuit board connections are reducedby 70%.

Introduction

Page 3: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

140

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

The KFD0-CS-1.50 current repeater is afully floating isolator for standard 4-20 mAinstruments. The inputs are galvanicallyisolated from the outputs. Typicalapplications include driving I/P convertersand isolating 2-wire transmitters.

OPERATION:

The KFD0-CS-1.50 is a single-channeldevice that does not require a separatepower supply. Due to the 24 VDC inputvoltage limitation and the internal voltagedrop, the maximum output voltage underload is 23 VDC. The maximum internalresistance is 230 ohms. At input voltagesgreater than 26.1 V, the internal voltagedrop is lower than with input voltagesbelow 26.1 V.

KFD0-CS-1.50

4-20 mA isolator

Single-channel

Loop powered

Power Supply Loop powered (not intrinsically safe)Nominal voltage 12-35 VDC

Input Terminals 11+, 12-Input voltage (Vin) 10-35 VDCInput current (Uin) 4-20 mA

Power Dissipation@ 25 mA (Vin < 26.1 V) < 150 mW@ 25 mA (Vin > 26.1 V) < 400 mW

Output Terminals 1, 2Output voltage: 10 V < Vin < 26.1 V 0.9 x Vin - (0.23 x current in mA) - 0.7 Vin > 26.1 V 23 V - (0.23 x current in mA)Output current 4-20 mAShort circuit current ≤ 65 mA @ Vin>26.1 VTransfer current ≤ 40 mA

Transfer CharacteristicsCalibrated accuracy ±20 µA for 1 kΩ load @ 20ºC

(includes linearity and hysteresis)Temperature drift ≤ 2 µA / ºCResponse time ≤ 5 ms (@ 4-20 mA and Vin < 26 V)Isolation 2500 VDC

MechanicalHousing: Material Makrolon Style KF style (see page 387) Mounting 35mm DIN rail or surface mountDimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)

Ambient Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Current Repeater/Driver SingleChannel Isolator

KFD0-CS-1.50

OutputInput2 (–)

1 (+) (+) 11

(– ) 12

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

Page 4: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

141

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

CurrentRepeater/DriverDual Channel Isolator

The KFD0-CS-2.50 current repeater is afully floating isolator for standard 4-20 mAinstruments. Each channel works as a DCisolator with the inputs galvanically isolatedfrom the outputs. Typical applicationsinclude driving I/P converters and isolating2-wire transmitters.

OPERATION:

The KFD0-CS-2.50 is a dual-channeldevice that does not require a separatepower supply. Due to the 24 VDC inputvoltage limitation and the internal voltagedrop, the maximum output voltage underload is 23 VDC. The maximum internalresistance is 230 ohms. At input voltagesgreater than 26.1 V, the internal voltagedrop is lower than with input voltagesbelow 26.1 V.

KFD0-CS-2.50

4-20 mA isolator

Dual-channel

Loop powered

KFD0-CS-2.50

Output 1Input 12 (– )

1 (+)

Output 25 (– )

4 (+)

Input 2

(– ) 12

(+) 11

(– ) 10

(+) 9

(+) 8

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

Power Supply Loop powered (not intrinsically safe)Nominal voltage 12-35 VDC

Input Terminals 11+, 12- ; 8+, 9+, 10-Input voltage (Vin) 10-35 VDCInput current (Uin) 4-20 mA

Power Dissipation@ 25 mA (Vin < 26.1 V) < 150 mW@ 25 mA (Vin > 26.1 V) < 400 mW

Output Terminals 1+, 2-; 4+, 5-Output voltage: 10 V < Vin < 26.1 V 0.9 x Vin - (0.23 x current in mA) - 0.7 Vin > 26.1 V 23 V - (0.23 x current in mA)Output current 4-20 mAShort circuit current ≤ 65 mA @ Vin>26.1 VTransfer current ≤ 40 mA

Transfer CharacteristicsCalibrated accuracy ±20 µA for 1 kΩ load @ 20ºC

(includes linearity and hysteresis)Temperature drift ≤ 2 µA / ºCResponse time ≤ 5 ms (@ 4-20 mA and Vin < 26 V)Isolation 2500 VDC

MechanicalHousing: Material Makrolon Style KF style (see page 387) Mounting 35mm DIN rail or surface mountDimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)

Ambient Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Page 5: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

142

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

The KFD0-CC-1 loop powered, 2-wireisolator that converts 2-wire voltage/current signals to a 4-20 mA signal.

The KFD0-CC-1 provides galvanicisolation for the loop. The required inputrange is set by a switch on the side of theunit. Zero and span adjustment areachieved by potentiometers on the top ofthe isolator.

KFD0-CC-1

Field selectable voltage orcurrent input

Loop-powered

Isolation of input/output

Power Supply Loop powered (not intrinsically safe)Nominal voltage 12-35 VDC

Input (selectable) Terminals 1+, 2-Input 0-20 mACurrent load ≤ 50 ΩInput voltage (Vin) 0-10 VDCVoltage load ≤ 100 kΩ

Output Terminals 9+, 8-Output 4-20 mABurnout fault signal Downscaled ≤ 3 mALoad/Ohm (Us - 12 V) / 0.02 A

Transfer CharacteristicsVoltage surge 6.5 ppm / VCalibrated accuracy ±0.1% of final value @ 20ºCLinearity fault ≤ 0.04% of final valueTemperature drift 0.050% of range / ºC

0.060% of span / ºCResponse time ≤ 250 msGalvanic Isolation safe isolated per DIN VDE 01061

design isolation voltage 253 VEff

MechanicalHousing: Material Makrolon Style KF housing (see page 387) Mounting 35mm DIN rail or surface mountDimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

OperatingTemperature -20ºC to +60ºC (-4ºF to +140ºF)

Current/VoltageConverter SingleChannel Isolator

KFD0-CC-1

Input Output8 (– )

9 (+)

(– ) 2

(+) 1

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

Page 6: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

143

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

Voltage to CurrentConverter SingleChannel Isolator

The KFD0-VC-1.50m receives a -50 to+50 mV signal input and produces a 4-20mA output. This loop powered module alsoprovides galvanic isolation.

The sensing range of the bipolar input unitisolates and conditions a 4-20 mA output.Fine adjustment for zero and span areperformed with the potentiometer on topof the unit.

Optional lead monitoring is available by thefield configurable DIP switches. Enablingthis feature produces an output ≤ 3 mAwhen the input wire is broken, whiledisabling produces an output ≥ 22 mA.

KFD0-VC-1.50m

-50 mV to + 50 mV voltage incurrent output isolator

Loop powered

Lead breakage monitoring

Power Supply Loop powered (not intrinsically safe)Nominal voltage 12-35 VDC

Input Terminals 1+, 3-Input voltage -50 to + 50 mVInput current Input monitoring on ≤ 15 nA

Input monitoring off ≤ 1 nA

Output Terminals 9+, 8-Output 4-20 mALead breakage enabled: ≤ 3 mA; disabled: ≥ 22 mA

Transfer CharacteristicsSensing range - 50 mV to +50 mV

Zero point 1% of final valueSpan ± 3.5% of final value

Temperature drift Zero point 0.01% of the span / ºC or±1 µV / ºC (whichever is larger)Span 0.005% of span / ºC

Response time ≤ 250 msGalvanic isolation safe isolated per DIN VDE 01061

design isolation voltage 253 VEff

MechanicalHousing: Material Makrolon Style KF housing (see page 387) Mounting 35mm DIN rail or surface mountDimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

Ambient Temperature -20ºC to +60ºC (-4ºF to +149ºF)

KFD0-VC-1.50m

Input Output8 (– )

9 (+)

(– ) 3

(+) 1

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

Page 7: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

144

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

The KFD0-VC-1.10 receives a -10 to +10voltage input and produces a 4-20 mAsignal output. This loop powered modulealso provides galvanic isolation.

The sensing range of the bipolar input unitisolates and conditions a 4-20 mA output.Fine adjustment for zero and span areperformed with the potentiometer on topof the unit.

KFD0-VC-1.10

-10 to +10 voltage input/4-20mA output

Loop powered

Isolation of input/output

Power Supply Loop powered (not intrinsically safe)Nominal voltage 12-35 VDC

Input Terminals 1+, 2-Input -10 to +10 VLoad ≥ 100 kΩ

Output Terminals 9+, 8-Output 4-20 mA, ≤ 35 mALoad (Ohm) ≤ (power supply - 12 V) / 0.02 A

Transfer CharacteristicsOperating voltage 6.5 ppm / VCalibrated accuracy 0.1% of final valueLinearity faults ≤ 0.04% of final valueSensing range -10 V to +10 V

Span ± 1.5% of final valueZero point ±1% of final value

Temperature drift Span 0.005% of span / ºCZero point 0.060% of span / ºC

Response time 250 msGalvanic isolation Function isolation per EN 50178

design isolation voltage 253 Veff

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Voltage to CurrentConverter SingleChannel Isolator

KFD0-VC-1.10

Input Output8 (– )

9 (+)

(– ) 2

(+) 1

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

Page 8: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

145

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

Thermocouple/mV Input SingleChannel Isolator

The KFD0-TT-1 is a loop powered isolatorthat accepts thermocouple inputs andconditions to a 4-20 mA output.

Types E, J, K, N, R, S, and T thermocoupleinputs with internal cold junctioncompensation (CJC) with galvanicisolation. The input voltage is linear tooutput current, not proportional totemperature. Adjustable zero, span andburnout detection are field-configurable.

KFD0-TT-1

Internal CJC

Loop powered

Lead breakage and short circuitmonitoring

Input/output isolation

Field-selectable thermocouple inputs

Power Supply Loop powered (not intrinsically safe)Nominal voltage 12-35 VDC

Input Terminals 1+, 2-, 3-Thermocouple (terminals 1,2,3) E,J,K, N,R,S or T (CJC reference to 0ºC)

Input current Input monitoring ‘ON’ ≤ 15 nAInput monitoring ‘OFF’ ≤ 1 nA

Output Terminals 9+, 8-Output 4-20 mA, ≤ 35 mALead breakage Downscaled ≤ 3 mA

Upscaled > 22 mALoad (power supply - 12 V) / 0.02 A

Transfer CharacteristicsVoltage surge 6.5 ppm / VMeasuring range (adjustable) Span 4 to 60 mV

Zero point -12 to 60 mVCharacteristics Output voltage is proportional to inputCalibrated accuracy 0.1% of final value ±1ºC for cold pointTemperature drift Span 0.005% of span / ºC

Zero point 0.01% of span / ºC or ±1µV/ºC0.01% of span/ºC or ±0.03ºC/ºC (J,K,N,T,E)0.01% of span/ºC or ±0.06ºC/ºC (R, S)Cold point ±2.0ºC (calibrated at TA = 20ºC)

Response time ≤ 250 msGalvanic isolation Function isolation per EN50178

design isolation voltage 253 Veff

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 118Weight 150 g (5.3 oz.)Protection IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +149ºF)

KFD0-TT-1

Output8 (– )

Input (– ) 2

(+) 1

(– ) 3

Input for Thermocouple

Passive Output

9 (+)

8 (– )(+) 1

(+) 1

(– ) 3

(– ) 2

9 (+)

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

Page 9: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

146

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

KFD0-TR-1

Output8 (– )

9 (+)Input 1

(– ) 2

(+) 3

Passive Ouput

9 (+)

8 (– )

Input for Pt100

(– ) 2 (– ) 2

(+) 3 (+) 3

(– ) 2

1 1

The KFD0-TR-1 is a loop powered isolatorthat accepts Pt100 2- and 3-wire inputs andconditions them to a 4-20 mA output.

The KFD0-TR-1 provides galvanic isolationand burnout detection (≥22 mA). Field-configurable DIP switches allow linearizationto be turned on and off.

The loop powered 2-wire converter is suitedfor the connection of the Pt100 in 2- or 3-wire mode.

KFD0-TR-1

Loop powered

PT100, 2- and 3-wire

Lead breakage (LB) monitoring

Input/output isolation

Field-configurable inputs/outputs

RTD InputSingle ChannelIsolator

Power Supply Loop powered (not intrinsically safe)Nominal voltage 12-35 VDC

Input Terminals 1+, 2-, 3+Input PT100, 2- and 3-wire connectionLead resistance ≤ 100 Ω / leadTest current ≈ 1 mA

Output Terminals 9+, 8-Output 4-20 mA (35 mA max.)Lead breakage Upscaled ≥ 22 mALoad (Ohm) ≤ (power supply - 12 V) / 0.02 A

Transfer CharacteristicsVoltage surge 6.5 ppm / VMeasuring range Span w/o linearization 25ºC to 800ºC

Span with linearization 25ºC to 430ºCZero point w/o linearization -200ºC to 466ºCZero point with linearization -86ºC to 405ºC

Calibrated accuracy 0.1% of final accuracyLinearity fault w/o linearization ≤ 0.04% final value

with linearization ≤ 0.14% final valueTemperature drift span and zero point 0.015% / ºC or

± 10 mΩ / ºCResponse time ≤ 250 msGalvanic isolation Function isolation per EN50178

design isolation voltage 50 Veff

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 100 mmWeight 150 g (5.3 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Note: For information about programming, refer to page 209or to our website at www.am.pepperl-fuchs.com

Page 10: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

147

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

KFDX-DCI

DC Current Input 7 (– )

8 (+)

12 (– )

11 (+)DC PowerSupply

(– ) 2

(+) 1Analog Output

The KFDX-DCI accepts a DC current inputand provides a fully isolated proportionalcurrent or voltage output. In order to eliminateground loops, the I/O channel is opticallyisolated to 1800 VDC and transformerisolated from the power supply.

The input can be configured in the field forone of six current ranges from 1-100 mA.Output is linear to the input, configurable forfive ranges: 0-5 V, 0-10 V, 0-1 mA, 0-20 mAor 4-20 mA. The KFDX-DCI accepts bipolarinputs and offers selectable normal or reverseoutput modes of operation (4-20 mA, 20-4mA). For inputs that do not change in polarity,select unipolar operation.

The KFDX-DCI is equipped with a dualfunction power/signal status LED. When theunit is powered, this green LED turns on.When the input signal is over 110% of thefull scale range, the LED flashes at 8 Hz;below 0% it flashes at 4 Hz.

This unit is not intrinsically safe.

KFDX-DCI

Field configurable inputs andoutputs

Wide range of DC current inputs

3-way isolation

Accepts bipolar inputs

DC Current InputCurrent/VoltageOutput Isolator

Power Supply Terminals 11+, 12- or Power RailNominal voltage 9-30 VDC (unregulated acceptable)Power consumption ≤ 1.5 W, 1 W typicalInrush current ≤ 200 mA

Input Terminals 1+, 2-Input span 1-100 mAOverload ≤ 170 mA, 60 VDC on inputImpedance 20 Ω typicalZero 50% of full scale inputSpan 50% of full scale input

Output Terminals 7-, 8+Voltage output 0-5 V, 0-10 V Impedance < 10 Ω Drive ≤ 10 mACurrent Output 0-1 mA, 0-20 mA, 4-20 mA Impedance > 100 kΩ 0-1 mA 7.5 V, max. 7.5 kΩ 0/4-20 mA 12 V, max 600 Ω

Transfer CharacteristicsAccuracy (including linearity and hysteresis) 2 mA range ± 0.35% of full scale; 0.5% max. other ranges ± 1.0% of full scale; 0.2% max. stability ± 0.025% of full scale / ºC for zero spanIsolation 3-way, 1800 VDCCommon mode rejection DC to 60 Hz: 120 dBResponse time 200 ms, 400 ms max.

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 100 mmWeight 3.5 oz. (100 g)Protection (IEC) IP 20

Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)

Note: For information about programming, refer to page209 or to our website at www.am.pepperl-fuchs.com

Page 11: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

148

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

KFDX-DCV

DC Voltage InputCurrent/VoltageOutput Isolator

Power Supply Terminals 11+ and 12- or Power RailNominal voltage 9-30 VDC (unregulated acceptable)Power consumption ≤ 1.5 W, 1 W typical

Input Terminals 1+, 2-Voltage 10 mV to 100 VMaximum overload 200 VDCImpedance ≥ 100 kΩ typicalZero 50% of full scale inputSpan 50% of full scale input

Output Terminals 7-, 8+Type Selectable DC current or voltageVoltage output 0-5 V, 0-10 V Impedance < 10 kΩ Drive 10 mA, max.Current output 0-1 mA, 4-20 mA, 0-20 mA Impedance > 100 kΩ 0-1 mA 7.5 V, max. 7.5 kΩ 0/4-20 mA 12 V, max. 600 Ω

Transfer CharacteristicsAccuracy (all ranges) ± 0.1% of full scale: 0.2% max.Stability ± 0.025% of full scale / ºC max.Response time ≤ 400 ms, 200 ms typicalIsolation 3-way, 1800 VDCCommon mode rejection DC to 60 Hz, 120 dB

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 100 mmWeight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)

The KFDX-DCV accepts a DC voltage inputand provides a fully isolated proportionalcurrent or voltage output. In order to eliminateground loops, the I/O channel is opticallyisolated to 1,800 VDC and transformerisolated from the power supply.

The input can be configured in the field forone of twelve voltage ranges from 10 mV to100V. Output is linear to the input, configurablefor five ranges: 0-5 V, 0-10 V, 0-1 mA, 0-20mA, or 4-20 mA. The KFDX-DCV acceptsbipolar inputs and offers selectable normal orreverse modes of operation (4-20 mA, 20-4mA). For inputs which do not change inpolarity, select unipolar operation.

The KFDX-DCV is outfitted with a dual functionpower/signal status LED. When the unit ispowered, this green LED turns on. When theinput signal is over 110% of the full scalerange, the LED flashes at 8 Hz.

This unit is not intrinsically safe

Field-configurable inputs/outputs

3-way isolators

Accepts bipolar inputs

Wide range of DC voltage inputs

Note: For information about programming, refer to page209 or to our website at www.am.pepperl-fuchs.com

KFDX-DCV

DC Voltage Input 7 (– )

8 (+)

12 (– )

11 (+)DC Power Supply

(– ) 2

(+) 1Analog Output

Page 12: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

149

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

KFD2-CR-1.300

KFD2-CR-1.300

DC Power Supply12 (–)

11 (+)

7 (– )

8 (+)

Input

(– ) 2

(+) 1

3

Analog Output

9 (– )

3

3

(+) 1

3

(+) 1

(– ) 2

(– ) 2

2- and 3-wire TransmitterInput 4-20 mA CurrentOutput Isolator

The KFD2-CR-1.300 is an isolator thatpowers and repeats a 4-20 mA signal froma 2- or 3-wire transmitter. It can also isolateand repeat signals from a current source.

For 2-wire transmitters, connected toterminals 1 and 3, there is 17.5 V at 20 mAavailable to the transmitter.

For 3-wire transmitters, the power is suppliedon terminals 1 and 2 with a 4-20 mA signalflowing into terminal 3. The voltage availableis approximately 16.5 V at 25 mA betweenterminals 1 and 2. Power, input and outputare galvanically isolated.

This unit is not intrinsically safe.

2- or 3-wire input

20-30 VDC power supply

4-20 mA output

3-way isolation

For information about programming, refer to page 209 or to our websiteat www.am.pepperl-fuchs.com

Power Supply Terminals 11+, 12- or Power RailNominal voltage 20-35 VDCPower consumption ≤ 1.7 W

Input Terminals 1+, 2-, 3Available voltage 2-wire: 17.5 V at 20 mA

3-wire: 16.5 V at 25 mAInput load (terminals 2, 3) 20 Ω

Output (not intrinsically safe) Terminals 7-, 8+, 9-Output signal 0-20 mAAvailable voltage 20 VDCLoad ≤ 1 kΩ

Transfer CharacteristicsAccuracy @ 20ºC ≤ ±10 µATemperature drift ≤ ±0.2 mA / ºC (0ºC to +60ºC)

±1.0 mA / ºC (-20ºC to 0ºC)Response time ≤ 50 µsGalvanic isolation, 3 way Isolation per EN50178

Isolation voltage 253 Veff

MechanicalHousing Material Makrolon Style KF Housing (see page 387)Dimensions (mm) 115 x 20 x 100 mmWeight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Page 13: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

150

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

KFD2-CD-1.32

KFD2-CD-1.32 KFD2-CD-1.32-2 KFD2-CD-1.32-8

2 (– )

1 (+)

8 (– )

7 (+) DC Power Supply

(+) 9 (+) 11 Analog

Output(– ) 10

Input

(+) 9

(– ) 10 (– ) 10

(+) 9

Current/VoltageDriver CurrentOutput Isolator

The KFD2-CD-1.32 provides three-wayisolation and is used for driving I/P converters,electrically operated valves and positioners.The KFD2-CD-1.32 is available in severalversions.

CURRENT INPUT OPTION

Current flowing into terminals 10 and 11(9)passes through resistor Internal Load,generating a voltage that is transferred to theDC/DC converter. A current limit circuit in linewith terminal 9 protects Rm from damage. Themaximum voltage drop across the input is only4 V at 20 mA, allowing the connection ofseveral KFD2-CD-1.32 input circuits in series.

VOLTAGE INPUT OPTION

Voltage within the specified input range istransferred to terminals 9 and 10 via anamplifier and a DC/DC converter. A voltagelimiter circuit protects the amplifier fromincorrect input switching and overvoltage, butwill draw current through a 50 mA fuse duringoperation.

CURRENT OUTPUT OPTION

Voltage transferred across the DC/DCconverter provides a proportional current atterminals 1 and 2. For all supply voltages, thereis a minimum of 17 V at 20 mA to drive loadsof up to 850 Ω.

This unit is not intrinsically safe.

KFD2-CD-1.32: 0/4 to 20mA input / outputKFD2-CD-1.32-2: 0-20mA input / 4-20mA outputKFD2-CD-1.32-8: 0-10V input / 4-20mA output

Current or voltage input options

20-30 VAC power supply

3-way isolation

Power Supply Terminals 7+, 8- or Power RailSupply voltage 20-35 VDCNominal current current output ≤ 50 mANominal current voltage output ≤ 20 mA

Input Terminals 9+, 10-, 11+Current input Voltage Input

Transmission range 0-20 mA 0-10 VMax. input current 40 mA N/AMax. input voltage 35 V 12 VDCVoltage drop ≤ 4 V at 20 mA N/AInput current N/A ≤10 µA to 50ºC w/ 10 V

Output Terminals 1+, 2-Current 0-20 mAVoltage 17 V at 20 mALoad resistance ≤ 850 Ω

Transfer CharacteristicsCalibrated accuracy @ 20ºC ±0.01% inc. nonlinearity and hysteresisTemperature drift per ºC ±0.01%Response time < 10 msGalvanic isolation Isolation per EN50178

Isolation voltage 253 Veff

MechanicalHousing Material Makrolon Style KF Housing (see page 387)Dimensions (mm) 115 x 20 x 100 mmWeight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Note: For information about programming, refer to page 209 or to ourwebsite at www.am.pepperl-fuchs.com

Page 14: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

151

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

KFD2-CR4-1.20

Single Input/DualOutput Transmitter/Repeater Isolator

Power Supply Terminals 14+, 15- or Power RailNominal voltage 20-32 VDCPower consumption ≈ 2.5 W

Input Terminals 1, 2, and 3Input signal 0-20 mAAvailable voltage ≥ 16 V at 20 mAInput resistance ≤ 85 Ω

Output Terminals 7-, 8+; 10-, 11+Output signal 0-20 mALoad 0-550 Ω

Transfer CharacteristicsCalibration accuracy ≤ ±20 µATemperature drift ≤ 20 ppm / ºCRise time 20 µs with 4-20 mA stageDe-energized delay 20 µs with 20-4 mA stageGalvanic isolation, 3-way Isolation per EN50178

Isolation Voltage 253 Veff

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 100 mmWeight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

The KFD2-CR4-1.20 is suited for theconnection of 2- and 3-wire transmitters.It may also be employed as a repeater for0-20 mA signals (current source).

Both outputs provide a 0-20 mA currentcorresponding to the input signal.

2-wire transmitters are connected toterminals 1 and 3. The input for the signalis terminal 3. The minimum availablevoltage is 16V at 20 mA. Current sourcesare connected to terminals 2 and 3.

The input, output and power supply aregalvanically isolated from each other.

This unit is not intrinsically safe.

Single-channel input /dual output

20-30 VDC supply voltage

Outputs isolated from each other

Power Rail Bus

3-way isolation

Note: For information about programming, refer to page 209 or to ourwebsite at www.am.pepperl-fuchs.com

KFD2-CR4-1.20

DC Power Supply15 (– )

14 (+)

7 (– )

8 (+) (– ) 2

(+) 1

3

Output 1

10 (– )

3 Input

3 3

(+) 1 (+) 1

(– ) 2

(– ) 2

11 (+)Output 2

Page 15: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

152

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

KFD2-STC4-1.20

HART TransmitterPower SupplyIsolator

Note: For information about programming, refer to page 209 or to ourwebsite at www.am.pepperl-fuchs.com

KFD2-STC4-1.20

DC Power Supply15 (– )

14 (+)

7 (– )

8 (+)

Input

(– ) 2

(+) 1

3

Output 1

10 (– )

3 3 3

(+) 1 (+) 1

(– ) 2 (– ) 2

11 (+)Output 2

SM

AR

T C

omm

unic

ator

Single channel input /dual output

HART compatible 4-20mA current source output 3-way isolation

SMART transmitter powers a 2-wireSMART transmitter and isolates the analog4-20 mA signal from the field to the controlroom as two current sources.

Digital signals which can be modulated ontothe analog signal, can also be transmittedbidirectionally.

The SMART transmitters are delivered withthe KF-STP-GN terminals. Connector jacksare integrated in these terminals for theconnection of the handheld terminals.

This unit is not intrinsically safe.

Power Supply Power Rail or terminals 14+, 15-Nominal voltage 20-32 VDCPower consumption ≈2.5 W

Input Terminals 1, 2, 3Input signal 0/4-20 mAAvailable voltage at 20 mA ≥16 V

Output Terminals 9+, 10-, 11+Output signal 4-20 mA / load 550 ΩRipple ≤ 50 µArms

Transfer CharacteristicsCalibrated accuracy ≤ 20 µATemperature drift ≤ 20 ppm / ºCFrequency range: Input/Output: Band width at 0.5 VppSignal 0 Hz to 7.5 kHz (-3 dB) Output/Input: Band width at 0.5 VppSignal 300 Hz to 7.5 kHz (-3 dB)Galvanic isolation Isolation per EN 50178

Isolation voltage 253 Veff

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 107 x 20 x 115 mmWeight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Page 16: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

153

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

KFDX-RTD

KFDX-RTD

7 (– )

8 (+)

12 (– )

11 (+)DC Power Supply

Analog Output

(+) 1

(R) 3

(– ) 2

RTD Input

RTD InputCurrent/VoltageOutput Isolator

The KFDX-RTD isolator interfaces 3-wire RTDs(Pt100, Pt500, Pt1000, Cu10, Cu25 andCu100) to a process control system. Thisisolator also effectively eliminates ground loopswith 1800 VDC isolation separating input,output and power supply.

The input range can be configured in the fieldfor one of sixteen temperature ranges via DIPswitches. The output is linear to temperature,configurable for five ranges: 0-5 V, 0-10 V, 0-1 mA, 0-20 mA or 4-20 mA.

Span and zero potentiometers provide 50%adjustability of offset and span turndown foreach input range. To ensure accuratetemperature measurement, the KFDX-RTDcontains constant current circuitry which usesthe third lead of the RTD as a sense line forlead resistance compensation.

The KFDX-RTD is equipped with three LEDs:INPUT (green), TROUBLE (yellow) and CAL(yellow). Upon power-up, the INPUT and CALLEDs will alternately flash for 10 seconds.

This unit is not intrinsically safe.

Field selectable inputs/ outputs

Wide range of RTD inputs

3-way isolation

Lead resistance compensation

Note: For information about programming, refer to page 209 or to ourwebsite at www.am.pepperl-fuchs.com

Power Supply Terminals 11+, 12- or Power RailSupply voltage 9-30 VDCPower consumption ≤ 2.5 W, 1.5 W typicalInrush current ≤ 300 mA

Input Terminals 1+, 2-, 3Excitation current < 2 mAZero 50% of full scale inputSpan 50% of full scale input

Output Terminals 7-, 8+Voltage output 0-5 V, 0-10 VImpedance > 10 ΩDrive ≤ 10 mACurrent output 0-1 mA, 0-20 mA, 4-20 mAImpedance > 100 kΩ0-1 mA 7.5 V, max. 7.5 kΩ0/4-20 mA 12 V, max. 600 ΩAccuracy (including linearity & hysteresis)

±0.01% typical, 0.2% max. of the max.input range @ 25ºC, 0Ω lead resistance

Temperature drift ±0.015% of max. temperature range/ºCResponse time ≤ 500 ms, 250 ms typicalIsolation 3-way 1800 VDC

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 100 mmWeight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Page 17: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

154

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

KFDX-TC

7 (– )

8 (+)

12 (– )

11 (+)DC Power Supply

(– ) 2

(+) 1

Analog Output

KFDX-TC

Thermocouple Input

Power Supply Terminals 11+ and 12- or Power RailSupply voltage 9-30 VDC (unregulated acceptable)Power consumption ≤ 2.5 W, 1.5 W typical

Input Terminals 1, 2Maximum overload ± 10 VDC on inputRange selectableImpedance ≥ 1 MΩBurnout detection selectable up/downscaleZero 50% of full scale inputSpan 50% of full scale input

Output Terminals 7-, 8+Voltage output 0-5 V, 0-10 VLine impedance > 10 ΩDrive ≤ 10 mACurrent output 0-1 mA, 0-20 mA, 4-20 mAImpedance > 100 kΩ0-1 mA 7.5 V, max. 7.5 kΩ0/4-20 mA 12V, max. 600 Ω

Transfer characteristicsTemperature drift < ±0.04% of max. input temperature

per ºC change in ambient temperatureCommon mode rejection DC to 60 Hz: 120 dBIsolation 3-way, 1,800 VDCResponse time ≤ 750 ms, 400 ms typical

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 100 mmWeight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)

ThermocoupleInput Isolator

The KFDX-TC thermocouple input isolatorinterfaces B, E, J, K, R, S and T typethermocouples to a process control system.It also effectively eliminates ground loops with1,800 VDC isolation separating input, outputand power supply.

The input range can be configured in the fieldfor one of 16 thermocouple temperatureranges via DIP switches on the side of thehousing. The output is linear to temperature,configurable for five ranges: 0-5 V, 0-10 V, 0-1 mA, 0-20 mA, or 4-20 mA.

Span and zero potentiometers on the top plateprovide 50% adjustability of offset and spanturn-down for each input range. The KFDX-TC also features internal cold junctioncompensation (CJC) and selectableupscale /downscale thermocouple burnoutdetection.

The KFDX-TC is outfitted with three LEDs onthe front panel: INPUT (Green), TROUBLE(Yellow), and CAL (Yellow). Upon power-up,the INPUT and CAL LEDs alternately flash for10 seconds.

This unit is not intrinsically safe.

Wide range of thermocouple types

Cold junction compensation (CJC)

24 VDC supply voltage

3-way isolation

Note: For information about programming, refer to page 209or to our website at www.am.pepperl-fuchs.com

Page 18: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

155

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

UniversalTemperatureInput Isolator

The KFD2-UT-1 is designed for connection toRTDs (Pt100 and Ni100) or thermocouples (B, E,J, K, L, N, R, S and T), and provides three-wayisolation. The inputs, outputs and power supplyare galvanically isolated.

This device also features internal/external coldjunction compensation, burnout monitoring forthermocouples and burnout and short circuitmonitoring for RTDs.

All settings are programmed and calibratedthrough a serial interface to PC (on-lineprogramming--see the P+F web site for moreinformation).

A signal at terminals 2 and 3 is transmitted acrossthe isolator and converted to an equivalent outputat terminals 7 and 8. Terminal 7 has the samepolarity as terminal 2.

All parameters are programmable through a K-ADP1 cable (sold separately) that provides theconnection between the programming socket ofthe KFD2-UT and the RS232 PC interface.

Accessories include removable terminals withinternal cold junction compensation (K-CJC) anda K-SK programming software kit. The K-ADP1and K-SK are required unless the KFD2-UT isconfigured by P+F.

This unit is not intrinsically safe.

KFD2-UT-1

Universal temperature inputs

Current output

Programming & calibration via PC

3-way isolation

CJC for thermocouple and leadresistance compensation for RTDs

Power Supply Terminals 11+, 12- or Power RailSupply voltage 20-35 VDCPower consumption ≈ 1.5 W

Input Terminals 1-, 2-, 3+, 4+Thermocouple B,E,J,K,L,N,R,S or TLead resistance ≤ 50 Ω per leadTest current 400 µA with RTDs

Output Terminals 7-, 8+Output current 4-20 mA (20.5 mA at input signal exceeded)Fault signal Downscaled 2-4 mA, upscaled 20.522 mALoad ≤ 500 Ω

Transfer CharacteristicsCalibrated accuracy ± (0.01% of value in ºC + 0.05% of

range + 0.1 ºC) (4-wire)Thermocouple ± (0.05% of value in ºC + 0.05% of

range + 1ºC) (inc. ± 0.8ºC error for CJC)

Rise time ≤ 430 msGalvanic isolation Isolation per EN50178

Isolation voltage 253 Veff

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature +4ºC to +60ºC (+40ºF to +140ºF)

12 (– )

11 (+)

8 (– )

7 (+) Analog Output4

3

2

1

PC

DC Power Supply

CJC Type K-CJC-GN

(– ) 2

(– ) 1

(– ) 2 (– ) 2 (– ) 2

(– ) 1

(+) 3 (+) 3

(+) 1

(+) 3

KFD2-UT-1

(+) 4

Input

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

Page 19: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

156

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

KFD2-UT-1-1

Universal temperature inputs

Voltage output

Programming & calibration via PC

3-way isolation

CJC for thermocouples and leadresistance compensation for RTDs

UniversalTemperatureInput Isolator

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

12 (– )

8 (– )

7 (+) Analog Output4

3

2

1

PC

DC Power Supply

CJC Type K-CJC-GN

(+) 4

(– ) 2

(– ) 1

(– ) 2 (– ) 2 (– ) 2

(– ) 1

(+) 3 (+) 3

(+) 1

(+) 3

KFD2-UT-1-1

11 (+)

Power Supply Terminals 11+, 12- or Power RailSupply voltage 20-35 VDCPower consumption ≈ 1.5 W

Input Terminals 1-, 2-, 3+, 4+Thermocouple B,E,J,K,L,N,R,S or TLead resistance ≤ 50 Ω per leadTest current 400 µA with RTDs

Output Terminals 7-, 8+Output voltage 1-5 V; (5.125 V input signal exceeded)Fault signal Downscaled 0-5 V, upscaled 5.025 - 5.12 VLoad ≤ 10 KΩ

Transfer CharacteristicsCalibrated accuracy ± (0.01% of value in ºC + 0.05% of

range + 0.1 ºC) (4-wire)Thermocouple ± (0.05% of value in ºC + 0.05% of

range + 1ºC) (inc. ± 0.8ºC error for CJC)

Rise time ≤ 430 msGalvanic isolation Isolation per EN50178

Isolation voltage 253 Veff

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature +4ºC to +60ºC (+40ºF to +140ºF)

The KFD2-UT-1-1 is designed for connection toRTDs (Pt100 and Ni100) or thermocouples (B,E, J, K, L, N, R, S and T), and provides three-way isolation. The inputs, outputs and powersupply are galvanically isolated.

This device also features internal/external coldjunction compensation, burnout monitoring forthermocouples and burnout and short circuitmonitoring for RTDs.

All settings are programmed and calibratedthrough a serial interface to PC (on-lineprogramming).

A signal at terminals 2 and 3 is transmitted acrossthe isolator and converted to an equivalentoutput at terminals 7 and 8. Terminal 7 has thesame polarity as terminal 2.

All parameters are programmable through a K-ADP1 cable (sold separately) that provides theconnection between the programming socketof the KFD2-UT and the RS232 PC interface.

Accessories include removable terminals withinternal cold junction compensation (K-CJC) anda K-SK programming software kit. The K-ADP1and K-SK are required unless the KFD2-UT-1-1is configured by P+F.

This unit is not intrinsically safe.

Page 20: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

157

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

AC Current/VoltageInput Current/VoltageOutput Isolator

The KFDX-AC accepts an AC voltage/currentinput and provides a fully isolated proportionalDC current or voltage output. In order toeliminate ground loops, the I/O channel isoptically isolated to 1,800 VDC andtransformer isolated from the power supply.

The input can be configured in the field forone of twelve voltage ranges from 100 mV to250 V and 4 current ranges from 10 mA to100 mA. Output is linear to the input,configurable for five ranges: 0-5 V, 0-10 V, 0-1 mA, 0-20 mA, or 4-20 mA.

The KFDX-AC is outfitted with a green dualfunction power/signal status LED. When theunit is powered, the LED is illuminated. Whenthe input signal is over 110% of the full scalerange, the LED flashes at 8 Hz.

This unit is not intrinsically safe.

KFDX-AC

Wide range of inputs/outputs

Field selectable input/output

3-way isolation

Power Supply Terminals 11+, 12- or Power RailSupply voltage 9-30 VDCPower consumption ≤ 1.5 W, 1 W typical

Input Terminals 1+, 2-Input voltage / current 100 mV to 250 V / 10-100 mAOverload ≤ 300 VAC / 170 mA AC (60 Vp for

current inputs)Impedance ≥ 100 kΩ (voltage inputs) / 20 Ω

(current inputs)Zero 50% of full scale inputSpan 50% of full scale input

Output Terminals 7-, 8+Voltage 0-5 V, 0-10 V Impedance < 10 kΩ Drive ≤ 10 mACurrent 0-1 mA, 4-20 mA, 0-20 mA Impedance > 100 kΩ 0-1 mA 7.5 V, max. 7.5 kΩ 0/4-20 mA 12 V, max. 600 Ω

Transfer CharacteristicsRange ± 0.1% of full scale: 0.5% max.Stability ± 0.025% of full scale/ºC for zero and spanCommon mode rejection DC to 60 Hz: 120 dBIsolation 3-way 1,800 VDCResponse time ≤ 400 ms, 200 ms typical

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

KFDX-AC

AC Input Current/Voltage 7 (– )

8 (+)

12 (– )

11 (+)DC Power Supply

(+) 1Analog Output(– ) 2

Page 21: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

158

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

The KFDX-HZ accepts a frequency inputand provides a fully isolated proportionalDC current or voltage output. This isolatoralso effectively eliminates ground loopswith 1,800 VDC isolation separating input,output and power supply.

The input range can be configured in thefield for any frequency span from 2 Hz to10,000 Hz via DIP switches on the side ofthe housing. The output is configurable forfive ranges: 0-5 V, 0-10 V, 0-1 mA, 0-20mA, or 4-20 mA.

The KFDX-HZ is simply configured viapush-buttons rather than a zero and spanpotentiometer. Set the input frequencyspan by applying the maximum andminmum frequencies to the system andpressing the CAL button while the INPUTLED is lit.

The KFDX-HZ is outfitted with three LEDs:LEVEL (Green), INPUT (Yellow), andOUTPUT (Red).

This unit is not intrinsically safe.

KFDX-HZ

Span from 2 Hz to 10,000 Hz

Easy push-button calibration

3-way isolation

Power Supply Terminals 11+, 12- or Power RailSupply voltage 9-30 VDCInrush current will not exceed stead state currentPower consumption ≤ 2.5 W, 1.4 W typical

Input Terminals 1+, 2-Range 2 Hz to 10 KHz, pulseInput values 150 mVp to 150 VrmsOverload ≤ 180 VrmsImpedance ≥ 10 kΩ

Output Terminals 7-, 8+Voltage output 0-5 V, 0-10 V Impedance > 1 kΩ Drive ≤ 10 mACurrent output 0-1 mA, 0-20 mA, 4-20 mA Impedance ≥ 100 kΩ 0-1 mA 7.5 V, max. 7.5 kΩ 0/4-20 mA 12 V, max. 600 Ω

Transfer CharacteristicsAccuracy ± 0.1% of selected range @ 25ºCTemperature drift ±0.025% / ºC max. of selected rangePower < ±0.01% of max. temp. range/% of

power changeCommon mode isolation DC to 60 Hz: 100 dBIsolation 3-way 1,800 VDCResponse time ≤ 500 ms, 250 ms typical

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)

Frequency InputCurrent/VoltageOutput Isolator

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

KFDX-HZ

Frequency Input 7 (– )

8 (+)

12 (– )

11 (+)DC PowerSupply

(– ) 2

(+) 1Analog Output

Page 22: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

159

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

Rotational SpeedLimit Alarm

KFA5-DWB-1.D

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

Power Supply Terminals 23, 24Nominal voltage 120 VACPower consumption 2 VA

Input Terminals 1+, 3-Connection type 2-wire sensor: terminals 1+, 3-

3-wire sensor: terminals 1+, 2- and 3start-up override terminals: 13+, 14-

Input I Sensor Input resistance 4.7 kΩ Input pulse length/interval ≥ 50 µs / ≥ 50 µs Voltage 22 V Current max. 30 mA; limitation 40 mA Lead monitoring breakage I ≤ 0.15 mA

short circuit I > 6.5 mAInput II start-up override: 1-1000 s, in 1s steps

Quiescent voltage/short circuit current: 18 V / 5 mA Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA

OutputsRelay output 1 (SPDT) Terminals 10, 11, 12Relay output 2 (SPDT) Terminals 16, 17, 18Contact load 250 VAC / 2 A / cos ø > 0.7; 40 VDC / 2 A

Mechanical life ≥ 5 x 107 operationsEnergizing / de-energizing ≈ 20 ms / ≈ 20 ms

Transfer CharacteristicsFrequency range 0.001-12,000 Hz

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 118 x 40 x 115Weight 300 g (10.6 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

The KFA5-DWB-1.D monitors for anoverspeed or underspeed condition bycomparing the input frequency to the userprogrammed reference frequency. Thereference frequency is easily programmedby the use of a keypad located on the frontof the unit. An overspeed or underspeedcondition is signaled via the relay outputs.Lead breakage and short circuits in thesensor are indicated by a red LED. Thestart-up override feature sets relay outputsto default conditions programmed by theuser, for up to 1,000 seconds.

This unit is not intrinsically safe.

Operating range 0.06-720,000RPM (0.001-12,000 Hz)

Relay outputs

Push-button programmable

Start-up override

LCD display

Lead breakage (LB) and shortcircuit (SC) monitoring

17

1618

111012

13 (+)14 (– )

23

24

Output 1

Output 2

Start Up Override

Supply 120 VAC

KFA5-DWB-1.D

(+) 1

(– ) 3

2

(+) 1

Input II

LB/SCLB/SC LB

R2

R1R1

(+) 1(+) 1(+) 1

(– ) 3(– ) 3(– ) 3(– ) 3

(+) 1

2

(– ) 3

Input I

Page 23: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

160

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

KFA6-DWB-1.D

Rotational SpeedLimit Alarm

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

17

1618

111012

13 (+)14 (– )

23

24

Output 1

Output 2

Start Up Override

Supply 240 VAC

KFA6-DWB-1.D

Sig

nal P

roce

sso

r(+) 1

(– ) 3

2

(+) 1

LB/SCLB/SC LB

R2

R1R1

(+) 1(+) 1(+) 1

(– ) 3(– ) 3(– ) 3(– ) 3

(+) 1

2

(– ) 3

Input II Input I

The KFA6-DWB-1.D monitors for anoverspeed or underspeed condition bycomparing the input frequency to the userprogrammed reference frequency. Thereference frequency is easily programmedby the use of a keypad located on the frontof the unit. An overspeed or underspeedcondition is signaled via the relay outputs.Lead breakage and short circuits in thesensor are indicated by a red LED. Thestart-up override feature sets relay outputsto default conditions programmed by theuser, for up to 1,000 seconds.

This unit is not intrinsically safe.

Operating range 0.06-720,000RPM (0.001-12,000 kHz)

Relay outputs

Push-button programmable

Start-up override

LCD display

Lead breakage (LB) and shortcircuit (SC) monitoring

Power Supply Terminals 23, 24Nominal voltage 240 VACPower consumption 2 VA

Input Terminals 1+, 3-Connection type 2-wire sensor: terminals 1+, 3-

3-wire sensor: terminals 1+, 2- and 3start-up override terminals: 13+, 14-

Input I Sensor Input resistance 4.7 kΩ Input pulse length/interval ≥ 50 µs / ≥ 50 µs Voltage 22 V Current max. 30 mA; limitation 40 mA Lead monitoring breakage I ≤ 0.15 mA

short circuit I > 6.5 mAInput II start-up override: 1-1000 s, in 1s steps

Quiescent voltage/short circuit current: 18 V / 5 mA Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA

OutputsRelay output 1 (SPDT) Terminals 10, 11, 12Relay output 2 (SPDT) Terminals 16, 17, 18Contact load 250 VAC / 2 A / cos ø > 0.7; 40 VDC / 2 A

Mechanical life ≥ 5 x 107 operationsEnergizing / de-energizing ≈ 20 ms / ≈ 20 ms

Transfer CharacteristicsFrequency range 0.001-12,000 Hz

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 118 x 40 x 115Weight 300 g (10.6 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Page 24: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

161

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

Rotational SpeedLimit Alarm

KFD2-DWB-1.D

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

17

1618

111012

13 (+)14 (– )

23 (+)

24 (– )

Output 1

Output 2

Start Up Override

Supply 24 VDC

KFD2-DWB-1.D

Sig

nal P

roce

sso

r

Collective Error Messaging

(+) 1

(– ) 3

2

(+) 1

LB/SCLB/SC LB

R2

R1R1

(+) 1(+) 1(+) 1

(– ) 3(– ) 3(– ) 3(– ) 3

(+) 1

2

(– ) 3

Input II Input I

The KFD2-DWB-1.D monitors foroverspeed or underspeed conditions bycomparing the input frequency to the user-programmed reference frequency. Thereference frequency is easily programmedby push buttons mounted on the frontpanel. An overspeed or underspeedcondition is signaled via the relay outputs.Lead breakage and short circuits in thesensor are indicated by a red LED andthrough the collective error output viaPower Rail. The start-up override featuresets relay outputs to default conditionsprogrammed by the user, for up to 1,000seconds.

This unit is not intrinsically safe.

Operating range 0.06-720,000RPM (0.001-12,000 Hz)

Relay outputs

Push-button programmable

Collective error messaging

LCD display

Lead breakage (LB) and shortcircuit (SC) monitoring

Power Supply Terminals 23, 24Nominal voltage 20-30 VDCPower consumption 2 W

Input Terminals 1+, 3-Connection type 2-wire sensor: terminals 1+, 3-

3-wire sensor: terminals 1+, 2- and 3start-up override terminals: 13+, 14-

Input I Sensor Input resistance 4.7 kΩ Input pulse length/interval ≥ 50 µs / ≥ 50 µs Voltage 22 V Current max. 30 mA; limitation 40 mA Lead monitoring breakage I ≤ 0.15 mA

short circuit I > 6.5 mAInput II start-up override: 1-1000 s, in 1s steps

Quiescent voltage/short circuit current: 18 V / 5 mA Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA

OutputsRelay output 1 (SPDT) Terminals 10, 11, 12Relay output 2 (SPDT) Terminals 16, 17, 18Contact load 250 VAC / 2 A / cos ø > 0.7; 40 VDC / 2 A

Mechanical life ≥ 5 x 107 operationsEnergizing / de-energizing ≈ 20 ms / ≈ 20 ms

Transfer CharacteristicsFrequency range 0.001-12,000 Hz

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 118 x 40 x 115Weight 300 g (10.6 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Page 25: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

162

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

KFU8-UFC-1

Universal FrequencyConverter

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

10

17161819 (+)20 (– )8 (+)7 (– )

1314

Output 1

Output 2

Output 3

Output 4 0/4-20 mA

Start Up Override

KFU8-UFC-1

Programming JackGND

TxDRxD

12

11

23

24Supply 24 VDC 120 VAC 240 VAC

(+) 1

(– ) 3

2

(+) 1

LB/SCLB/SC LB

R2

R1R1

(+) 1(+) 1(+) 1

(– ) 3(– ) 3(– ) 3(– ) 3

(+) 1

2

(– ) 3

Input II Input I

24 VDC / 120 VAC / 240 VAC supply

Operating range 0.06-720,000 RPM(0.001-12,000 kHz)

Analog and digital outputs

PC programmable

This universal frequency converter convertsa digital input signal into an analog outputsignal for connection to standard currentinput devices. A passive transistor outputisolates and transfers the digital signal.Two relay outputs can be programmed toactuate at desired frequencies. The unit isprogrammable with a PC and thePACTware configuration software.A debounce filter eliminates extraneoussignals from relay bounce.

Lead breakage and short circuits in thesensor are indicated by a red LED.

This unit is not intrinsically safe.

Power Supply Terminals 23, 24Nominal voltage 20-90 VDC; 40-250 VACPower consumption 2.2 W; 3 VA

InputConnection type 2-wire sensor: terminals 1+, 3-

3-wire sensor: terminals 1+, 2- and 3start-up override terminals: 13+, 14-

Input I Sensor Input resistance 4.7 kΩ Input pulse length/interval ≥ 50 µs / ≥ 50 µs Voltage 22 V Current (Im) max. 30 mA; limitation 40 mA Lead monitoring breakage I ≤ 0.15 mA

short circuit I > 6.5 mAInput II start-up override: 1-1000 s, in 1s steps Quiescent voltage/short circuit current: 18 V / 5 mA Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA

OutputsRelay output 1 (SPDT) Terminals 10, 11 and 12Relay output 2 (SPDT) Terminals 16, 17 and 18Contact load 250 VAC / 2 A / cos ø ≥ 0.7; 40 VDC / 2AMechanical life ≥ 5 x 107 operationsEnergizing / de-energizing delay ≈ 20 ms / ≈ 20 msOutput 3 (passive transistor) Terminals 19+ and 20-Nominal current 50 mA, short circuit-protectedLogic 1 voltage drop < 2.5 VLogic 0 output switched off (leakage < 10 µA)Output 4 (current) Terminals 8+ and 7-Open circuit voltage ≤ 24 VDCOutput current 0-20 mA or 4-20 mAError signal Downscale < 3.6 mA, upscale ≥ 22 mALoad ≤ 650 Ω

MechanicalHousing Makrolon KF housing (see page387)Dimensions (mm) 118 x 40 x 115Weight 300 g (10.6 oz.)

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Page 26: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

163

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

Universal FrequencyConverter with Display

KFD2-UFC-1.D

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

10

17161819 (+)20 (– )8 (+)7 (– )

13 (+)14 (– )

Output 1

Output 2

Output 3

Output 4 0/4-20 mA

Start Up Override

KFD2-UFC-1.D

Programming JackGND

TxDRxD

Collective Error Messaging

12

11

23 (+)

24 (– )Supply 24 VDC

(+) 1

(– ) 3

2

(+) 1

LB/SCLB/SC LB

R2

R1R1

(+) 1(+) 1(+) 1

(– ) 3(– ) 3(– ) 3(– ) 3

(+) 1

2

(– ) 3

Input II Input I

This universal frequency converter convertsa digital input signal into an analog outputsignal for connection to standard currentinput devices. A passive transistor outputisolates and transfers the digital signal. Tworelay outputs can be programmed toactuate at desired frequencies. The units isprogrammable with a PC and thePACTware configuration software. Adebounce circuit eliminates extraneoussignals from relay bounce.

Lead breakage and short circuits in thesensor are indicated by a red LED andthrough the collective error output viaPower Rail.

This unit is not intrinsically safe.

24 VDC supply

Operating range 0.06-720,000RPM (0.001-12,000 kHz)

Analog and digital outputs

PC and push-buttonprogrammable

LCD display

Power Supply Terminals 23, 24Nominal voltage 20-30 VDCPower consumption 2.2 W

InputConnection type 2-wire sensor: terminals 1+, 3-

3-wire sensor: terminals 1+, 2- and 3start-up override terminals: 13+, 14-

Input I Sensor Input resistance 4.7 kΩ Input pulse length/interval ≥ 50 µs / ≥ 50 µs Voltage 22 V Current (Im) max. 30 mA; limitation 40 mA Lead monitoring breakage I ≤ 0.15 mA

short circuit I > 6.5 mAInput II start-up override: 1-1000 s, in 1s steps Quiescent voltage/short circuit current: 18 V / 5 mA Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA

OutputsRelay output 1 (SPDT) Terminals 10, 11 and 12Relay output 2 (SPDT) Terminals 16, 17 and 18Contact load 250 VAC / 2 A / cos ø ≥ 0.7; 40 VDC / 2AMechanical life ≥ 5 x 107 operationsEnergizing / de-energizing delay ≈ 20 ms / ≈ 20 msOutput 3 (passive transistor) Terminals 19+ and 20-Nominal current 50 mA, short circuit-protectedLogic 1 voltage drop < 2.5 VLogic 0 output switched off (leakage < 10 µA)Output 4 (current) Terminals 8+ and 7-Open circuit voltage ≤ 24 VDCOutput current 0-20 mA or 4-20 mAError signal Downscale < 3.6 mA, upscale ≥ 22 mALoad ≤ 650 Ω

MechanicalHousing Makrolon KF housing (see page 387)Dimensions (mm) 118 x 40 x 115Weight 300 g (10.6 oz.)

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Page 27: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

164

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

KFD2-UFC-1

Universal FrequencyConverter Isolator

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

10

171618192087

1314

Output 1

Output 2

Output 3

Output 4 0/4-20 mA

Start Up Override

KFD2-UFC-1

Programming JackGND

TxDRxD

12

11

23

24Supply 24 VDC

(+) 1

(– ) 3

2

(+) 1

LB/SCLB/SC LB

R2

R1R1

(+) 1(+) 1(+) 1

(– ) 3(– ) 3(– ) 3(– ) 3

(+) 1

2

(– ) 3

Collective Error Messaging

Input II Input I

24 VDC supply

Operating range 0.06-720,000RPM (0.001-12,000 kHz)

Analog and digital outputs

PC programmable

This universal frequency converter convertsa digital input signal into an analog outputsignal for connection to standard currentinput devices. A passive transistor outputisolates and transfers the digital signal.Two relay outputs can be programmed toactuate at desired frequencies. The unit isprogrammable with a PC and thePACTware configuration software.A debounce filter eliminates extraneoussignals from relay bounce.

Lead breakage and short circuits in thesensor are indicated by a red LED andthrough the collective error output viaPower Rail.

This unit is not intrinsically safe.

Power Supply Terminals 23, 24 or Power RailNominal voltage 20-30 VDCPower consumption 2.2 W

InputConnection type 2-wire sensor: terminals 1+, 3-

3-wire sensor: terminals 1+, 2- and 3start-up override terminals: 13+, 14-

Input I Sensor Input resistance 4.7 kΩ Input pulse length/interval ≥ 50 µs / ≥ 50 µs Voltage 22 V Current (Im) max. 30 mA; limitation 40 mA Lead monitoring breakage I ≤ 0.15 mA

short circuit I > 6.5 mAInput II start-up override: 1-1000 s, in 1s steps Quiescent voltage/short circuit current: 18 V / 5 mA Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA

OutputsRelay output 1 (SPDT) Terminals 10, 11 and 12Relay output 2 (SPDT) Terminals 16, 17 and 18Contact load 250 VAC / 2 A / cos ø ≥ 0.7; 40 VDC / 2AMechanical life ≥ 5 x 107 operationsEnergizing / de-energizing delay ≈ 20 ms / ≈ 20 msOutput 3 (passive transistor) Terminals 19+ and 20-Nominal current 50 mA, short circuit-protectedLogic 1 voltage drop < 2.5 VLogic 0 output switched off (leakage < 10 µA)Output 4 (current) Terminals 8+ and 7-Open circuit voltage ≤ 24 VDCOutput current 0-20 mA or 4-20 mAError signal Downscale < 3.6 mA, upscale ≥ 22 mALoad ≤ 650 Ω

MechanicalHousing Makrolon KF housing (see page 387)Dimensions (mm) 118 x 40 x 115Weight 300 g (10.6 oz.)

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Page 28: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

165

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

Universal FrequencyConverter Isolatorwith Display

KFU8-UFC-1.D

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

10

17161819 (+)20 (–)8 (+)7 (–)

13 (+)14 (– )

Output 1

Output 2

Output 3

Output 4 0/4-20 mA

Start Up Override

KFU8-UFC-1.D

Programming JackGND

TxDRxD

12

11

23

24Supply 24 VDC 120 VAC 240 VAC

(+) 1

(– ) 3

2

(+) 1

LB/SCLB/SC LB

R2

R1R1

(+) 1(+) 1(+) 1

(– ) 3(– ) 3(– ) 3(– ) 3

(+) 1

2

(– ) 3

Input II Input I

This universal frequency converter convertsa digital input signal into an analog outputsignal for connection to standard currentinput devices. A passive transistor outputisolates and transfers the digital signal. Tworelay outputs can be programmed toactuate at desired frequencies. The units isprogrammable with a PC and thePACTware configuration software. Adebounce circuit eliminates extraneoussignals from relay bounce.

Lead breakage and short circuits in thesensor are indicated by a red LED.

This unit is not intrinsically safe.

24 VDC / 120 VAC / 240 VAC supply

Operating range 0.06-720,000 RPM(0.001-12,000 kHz)

Analog and digital outputs

PC and push-buttonprogrammable

LCD display

Power Supply Terminals 23, 24Nominal voltage 20-90 VDC; 40-250 VACPower consumption 2.2 W; 3 VA

InputConnection type 2-wire sensor: terminals 1+, 3-

3-wire sensor: terminals 1+, 2- and 3start-up override terminals: 13+, 14-

Input I Sensor Input resistance 4.7 kΩ Input pulse length/interval ≥ 50 µs / ≥ 50 µs Voltage 22 V Current (Im) max. 30 mA; limitation 40 mA Lead monitoring breakage I ≤ 0.15 mA

short circuit I > 6.5 mAInput II start-up override: 1-1000 s, in 1s steps Quiescent voltage/short circuit current: 18 V / 5 mA Active / passive I > 4 mA (> 100 ms) / I < 1.5 mA

OutputsRelay output 1 (SPDT) Terminals 10, 11 and 12Relay output 2 (SPDT) Terminals 16, 17 and 18Contact load 250 VAC / 2 A / cos ø ≥ 0.7; 40 VDC / 2AMechanical life ≥ 5 x 107 operationsEnergizing / de-energizing delay ≈ 20 ms / ≈ 20 msOutput 3 (passive transistor) Terminals 19+ and 20-Nominal current 50 mA, short circuit-protectedLogic 1 voltage drop < 2.5 VLogic 0 output switched off (leakage < 10 µA)Output 4 (current) Terminals 8+ and 7-Open circuit voltage ≤ 24 VDCOutput current 0-20 mA or 4-20 mAError signal Downscale < 3.6 mA, upscale ≥ 22 mALoad ≤ 650 Ω

MechanicalHousing Makrolon KF housing (see page 387)

Dimensions (mm) 118 x 40 x 115Weight 300 g (10.6 oz.)

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Page 29: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

166

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

The KFDA-DCI accepts a DC current inputand provides two adjustable contactoutputs. This limit alarm also effectivelyeliminates ground loops with 1,800 VDCisolation separating input, output andpower supply.

The KFDA-DCI is outfitted with threeLEDs. The first is a green INPUT LEDwhich indicates DC power and input signalstatus. If this LED is not illuminated uponpower-up, check wiring connections.When the signal is over 110% of the fullscale range, the INPUT LED flashes at 8Hz; below 0% it flashes at 4 Hz. Eachsetpoint has its own red LED that indicatesthe relay state. An il luminated LEDindicates a tripped condition.

This unit is not intrinsically safe.

KFDA-DCI

Wide range of DC current inputs

Field configurable input/output

3-way isolation

Accepts bipolar inputs

Power Supply Terminals 11+, 12- or Power RailNominal voltage 9-30 VDCPower consumption ≤ 2.5 W, 1.8 W typical

Input Terminals 1+, 2-Input current 1-100 mAExcitation (terminal 3+) 24 VDC @ 20 mAMaximum overload 170 mA max., 60 VDC on inputImpedance 20 Ω typical

Output Terminals 4, 5, and 6; 7, 8, and 9Type 2 SPDT (Form C) relaysCurrent ratings (resistive loads) 120 VAC @ 5A

240 VAC @ 2A28 VDC @ 5A

Mechanical life ≥ 107 operations

Repeatability (constant temp.)> 5 mA 0.1% of full scale< 5 mA 0.2% of full scaleLimit Differentials (deadbands)> 5 mA ±0.25-5% of span< 5 mA 1-5% of spanStabilityTemperature drift ±0.05% of full scale / ºC (max.)Power ±0.01% of full scale / % of power changeCommon Mode Rejection DC to 60 Hz: 120 dBIsolation 3-way 1,800 VDCResponse timeDynamic Deadband relay condition changes when proper

condition exists for 100 msNormal mode (analog filter) ≤ 400 ms, 200 ms typical

MechanicalHousing Makrolon KF style housing (see page 387)

Dimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)

DC Current Input2 Form C ContactOutputs Isolator

KFDA-DCI

DC Input(+) 1

Output A Output B

DC Power Supply

(+24 VDC) 3

(– ) 2 4 5 6

7 8 9

11 (+) 12 (– )

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

Page 30: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

167

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

DC Voltage Input2 Form C ContactOutputs Isolator

The KFDA-DCV accepts a DC voltage inputand provides two adjustable relay outputs.This limit alarm also effectively eliminatesground loops with 1,800 VDC isolationseparating input, output and power supply.

Setpoints can be configured as HI or LO inselectable controlsafe or non-controlsafeoperating modes. The KFDA-DCV relies ondeadband (hysteresis) and constant samplingof the input to prevent false switching whenthe input varies slightly on either side of thesetoint. The input must remain beyond thesetpoint for 100ms, uninterrupted, to qualifyas a valid trip condition. To return the alarmto an untripped condition, the input signalmust be outside the deadband and remainthere for 100 ms. This time-based dynamicdeadband, in addition to the evaluation ofhysteresis, improves setpoint stability. Selectunipolar operation for inputs that do notchange in polarity.

The KFDA-DCV is equipped with three LEDs.The first is a green INPUT LED which indicatesDC power and input signal status. If this LEDdoes not illuminate on power-up, check wiringconnections. When the signal input is over110% of the full scale range, the INPUT LEDwill flash at 8 Hz; below 0% it will flash at 4Hz. Each setpoint has its own LED whichindicates the relay state; an illuminated LEDindicates a tripped condition.

This unit is not intrinsically safe.

KFDA-DCV

Wide range of DC voltage inputs

Field configurable inputs/outputs

3-way isolation

2 adjustable, independent relaycontact outputs

Power Supply Terminals 11+, 12- or Power RailNominal voltage 9-30 VDCPower consumption ≤ 2.5 W, 1.8 W typicalInrush current ≤ 300 mA max.

Input Terminals 1+, 2-Input voltage 10 mV to 200 VExcitation (terminal 3+) 24 VDC @ 20 mAImpedance > 100 kΩ typical

Output Terminals 4, 5, and 6; 7, 8 and 9Current rating (resistive loads) 120 VAC @ 5 A

240 VAC @ 2 A28 VDC @ 5 A

Mechanical life ≥ 107 operationsRepeatability (constant temperature):> 50 mV 0.1% of full scale< 50 mV 0.2% of full scaleLimit differentials (deadbands):> 50 mV 0.25-5% of span< 50 mV 1-5% of spanTemperature drift ± 0.05% of full scale / ºC (max.)Power ±0.01% of full scale/% of power changeCommon mode rejection DC to 60 Hz: 120 dBIsolation 3-way 1,800 VDCResponse time:Dynamic deadband relay condition changes when proper

condition exists for 100 msNormal mode (analog filtering) < 200 ms typical, 400 ms max.

MechanicalHousing Makrolon KF style housing (see page 387)Dimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

KFDA-DCV

DC Input(+) 1

Output A Output B

DC Power Supply

(+24 VDC) 3

(– ) 2 4 5 6

7 8 9

11 (+) 12 (– )

Page 31: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

168

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

The KFD2-GS-1.2W is a trip amplifier for twoindependently field-configurable limit alarms.Three-way galvanic isolated units convert 0/4-20mA, 0/1-5 V and 0/2-10 V signals into trip pointoutputs.

For high alarm indication, the status of the contactoutput changes when the setpoint is exceededand will not reset until a lower value is met. Thedifference between these states is the adjustablehysteresis.

The trip alarm is adjustable by a selector switchand potentiometer.

A monitoring voltage output of 0-10 V can be usedto adjust limit values and hysteresis withoutinterrupting the input signal.

This unit is not intrinsically safe.

KFD2-GS-1.2W

Single-channel, 24 VDC supply

Current and voltage analog inputs

2 programmable trip points

Power Supply Terminals 14+, 15- or Power RailNominal voltage 20-30 VDCNominal current ≤ 75 mAPower consumption ≤ 2.25 W, 1.68 W typical

InputMeasuring range voltage (terminals 1+, 3-) 0/1-5 VInput load 50 kΩMeasuring range voltage (terminals 1+, 3-) 0/2-10 VInput load 100 kΩMeasuring range voltage (terminals 2+, 3) 0/4-20 mAInput load 50 Ω

OutputOutput I (terminals 7, 8, 9) trip value 1Output II (terminals 10, 11, 12) trip value 2Contact load AC: 250V / 5A / 1250VA

DC: 125V / 5A / 150 W

FunctionResponse time 100 msAccuracy/repeatability < 0.5%Temperature drift 0.01% / ºC in reference to set limitsIsolation 1000 V

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 118Weight 120 g (4.2 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

DC Current/VoltageInput 2 Form C ContactOutputs Isolator

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

8

79

14

1

Output 1

Output 2

Supply 24 VDC

KFD2-GS-1.2W

3

2

5

4

6

15

11

1012

Feed Back

Trip Value 1

Trip Value 2

0V...10V 2V...10V

0mA...20mA 4mA...20mA

Dip switchfunctionson sideof unit

Switch Position Function

S1.1 0 0/2V...10V input range1 0/1V...5V input range

S1.2 0 Low alarm output 11 High alarm output 1

S1.3 0 Low alarm output 111 High alarm output 11

S1.4 0 Relays open in alarm state output 11 Relays closed in alarm state output 1

S1.5 0 Relays open in alarm state output 111 Relays closed in alarm state output 11

S1.6 0 Output 1 independent of output 111 Limit 1 responds to both outputs

1 2 3 4 5 6

1

0

Inputrange

ON: Limit 1responds toboth outputs

High-/Low alarmMode ofoperation

Page 32: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

169

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

TransmitterPower SupplyIsolator

The KFD2-CRG-1.D transmitter powersupply is suited for a variet of measuringtasks. 2- and 3-wire transmitters as wellas active power supplies with 0/4-20 MAsignals can be connected. Two relays andan active 0/4-20 mA current output areavailable.

The input has lead breakage and short-circuit monitoring.

Programming is via a PC (usingPACTware) or by using the control panelon the front of the device.

This unit is not intrinsically safe.

KFD2-CRG-1.D

Current source or transmitterinputs

Analog output 0/4-20 mA

2 relay outputs

Lead breakage andshort-circuit monitoring

Galvanic isolation

Power Supply Terminals 23+, 24- or Power RailNominal voltage 20-30 VDCMax. voltage Um 40 VDCPower consumption ≈ 2.2 W

Input Terminals 1, 2 and 3Input signal 0/4-20 mAAvailable voltage ≥ 15 V at 20 mA

OutputOutput I Terminals 10, 11, 12Output II Terminals 16, 17, 18 Output I & II type Form C, SPDT contact Contact loading 250 VAC / 2A / cos ϕ ≥ 0.7; 40 VDC/2A Maximum voltage (Um) 40 VDC Pull-in/drop-out delay ≈ 20 ms / ≈ 20 msMechanical life 5 x 107 operationsOutput III Terminals 7, 8: analog signal Current range 0/4-20 mA Quiescent voltage ≤ 24 VDC Load ≤ 650Ω

Transfer CharacteristicsAccuracy 0.1% of full scale value (output < 10µA)Temperature current measurement: 0.003% / ºC

current output: 0.005% / ºCcurrent measurement & output: 0.006% / ºC

Linearization current measurement andcurrent output 0.025%

Input delay ≤ 200 msIsolation Galvanic isolation

MechanicalHousing Makrolon KF style housing (see page 387)Dimensions (mm) 115 x 40 x 118Weight 300 g (10.5 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +149ºF)

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

24 (– )23 (+)

8 (+)7 (– )

Output

PCDCV Power Supply

KFD2-CRG-1.D

Input

(– ) 2

(+) 1

3

3 3

3

(+) 1 (+) 1

(– ) 2

(– ) 2 101112161718

Output 1

Output 2

0/4...20mA

Collective Error Messaging

Relay 1

Relay 2

Page 33: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

170

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

KFU8-CRG-1.D

Transmitter PowerSupply Isolator

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

24 (– )23 (+)

8 (+)7 (– )

Output

PC

Universal Power

KFU8-CRG-1.D

Input

(– ) 2

(+) 1

3

3 3

3

(+) 1 (+) 1

(– ) 2

(– ) 2 101112161718

Output 1

Output 2

0/4...20mA

Relay 1

Relay 2

The KFU8-CRG-1.D transmitter powersupply is suited for a variety of measuringtasks. 2- and 3-wire transmitters as wellas active power supplies with 0/4-20 MAsignals can be connected. Two relays andan active 0/4-20 mA current output areavailable.

The input has lead breakage and shortcircuit monitoring.

The universal power requirement allowsAC or DC power of unit.

Programming is via a PC (using PACTware)or by using the control panel on the frontof the device.

This unit is not intrinsically safe.

Current source or transmitter inputs

Analog output 0/4-20 mA

2 relay outputs

Lead breakage andshort-circuit monitoring

Galvanic isolation

Power Supply Terminals 23, 24Nominal voltage 20-90 VDC or 48-253 VACMax. voltage Um 253 VDCPower consumption ≈ 2.2 W / 2.5 VA

Input Terminals 1, 2 and 3Input signal 0/4-20 mAAvailable voltage ≥ 15 V at 20 mA

OutputOutput I Terminals 10, 11, 12Output II Terminals 16, 17, 18 Output I & II type Form C, SPDT contact Contact loading 250 VAC / 2A / cos ϕ ≥ 0.7; 40 VDC/2A Maximum voltage (Um) 40 VDC Pull-in/drop-out delay ≈ 20 ms / ≈ 20 msMechanical life 5 x 107 operationsOutput III Terminals 7, 8: analog signal Current range 0/4-20 mA Quiescent voltage ≤ 24 VDC Load ≤ 650Ω

Transfer CharacteristicsAccuracy 0.1% of full scale value (output < 10µA)Temperature current measurement: 0.003% / ºC

current output: 0.005% / ºCcurrent measurement & output: 0.006% / ºC

Linearization current measurement andcurrent output 0.025%

Input delay ≤ 200 msIsolation Galvanic isolation

MechanicalHousing Makrolon KF style housing (see page 387)

Dimensions (mm) 115 x 40 x 118Weight 300 g (10.5 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +149ºF)

Page 34: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

171

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

Thermocouple Input2 Form C ContactOutputs Isolator

The KFDA-TC accepts a B, E, J, K, S, R or Ttype thermocouple input and provides twoadjustable contact outputs. This limit alarm alsoeffectively eliminates ground loops with 1,800VDC isolation separating input, output and powersupply. The KFDA-TC is configurable for multipletemperature ranges per thermocouple type. Italso accepts bipolar inputs and offers selectableupscale and downscale burnout detection.

Setpoints can be configured as HI or LO inselectable controlsafe or non-controlsafeoperating modes. The KFDA-TC relies ondeadband (hysteresis) and constant sampling ofthe input to prevent false switching when the inputvaries slightly on either side of the setpoint. Theinput must remain uninterrupted beyond thesetpoint for 100 ms to qualify as a valid tripcondition. To return the alarm to an untrippedcondition, the input signal must fall outside thedeadband and remain there for 100 ms. Thistime-based dynamic deadband improvessetpoint stability.

The KFDA-TC is equipped with three LEDs. Thefirst is a green INPUT LED which indicates DCpower and input signal status. If this LED doesnot illuminate during power-up, check wiringconnections. When the input signal is over 110%of the full scale range, the INPUT LED flashes at8 Hz; below 0% it flashes at 4 Hz. Each setpointhas its own red LED that indicates the relay state.An illuminated LED indicates a tripped condition.

This unit is not intrinsically safe.

KFDA-TC

Wide input range of thermocouples

Field configurable input/output

3-way isolation

2 adjustable independent relaycontact outputs

Power Supply Terminals 11+, 12- or Power RailNominal voltage 9-30 VDCPower consumption ≤ 2.5 W, 1.8 W typicalInrush current ≤ 300 mA

Input (not intrinsically safe) Terminals 1+, 2-Thermocouples B,E,J,K,R,S or TOverload ≤ ±10 VDC on inputImpedance > 1 MΩBurnout detection < 1.5 µA

Output (not intrinsically safe) Terminals 4, 5, and 6; 7, 8, and 9Type 2 SPDT (Form C) relaysCurrent rating 120 VAC @ 5 A

240 VAC @ 2 A28 VDC @ 5 A

Mechanical life ≥ 107 operationsRepeatability (constant temp.) 0.2% for temp. > 0ºC

0.3% for temp. < 0ºCLimit differentials (deadbands) 0.25-5% of spanTemperature drift ±0.05% of full scale / ºC (max.)Power ±0.01% of full scale / % power changeCommon mode rejection DC to 60 Hz: 120 dBIsolation 3-way 1,800 VDC

Response timeDynamic deadband relay condition changes when proper

condition exists for 100 msNormal mode (analog filter) < 250 ms

MechanicalHousing Material Makrolon Style KF housing (see page 387)Dimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

KFDA-TC

DC PowerSupply

11 (+) 12 (– )

7 8 9

Output B

(+) 1

(– ) 2

4 5 6

Output A

Thermocouple Input

Page 35: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

172

Technical Data

Connection Diagram

Model Number

2002 IS CatalogS

ignal C

ondit

ioners

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

The KFDA-RTD limit alarm accepts a 3-wire RTDinput (Pt100, Pt500, Pt1000, Cu10, Cu100, Ni120,NiFe604) and provides two adjustable relayoutputs. This limit alarm also effectively eliminatesground loops with 1,800 VDC isolation separatinginput, output and power supply. The KFDA-RTDis configurable for up to eight temperature rangesfor each RTD type.

Setpoints can be configured as HI or LO inselectable controlsafe or non-controlsafe operatingmodes. The KFDA-RTD relies on deadband(hysteresis) and constant sampling of the input toprevent false switching when the input variesslightly on either side of the setpoint. The inputmust remain uninterrupted beyond the setpointfor 100 ms to qualify as a valid trip condition. Toreturn the alarm to an untripped condition, theinput signal must fall outside the deadband andremain there for 100 ms. This time-based dynamicdeadband improves setpoint stability.

The KFDA-RTD is outiftted with three LEDs. Thefirst is a green INPUT LED which indicates DCpower and input signal status. If this LED is notilluminated at power-up, check wiring connections.When the input signal is over 110% of the full scalerange, the INPUT LED flashes at 8 Hz; below 0%it flashes at 4 Hz. Each setpoint has its own redLED that indicates the relay state. An illuminatedLED indicates a tripped condition.

This unit is not intrinsically safe.

KFDA-RTD

Wide input range of RTD

Field configurable input/output

3-way isolation

2 adjustable independent relaycontact outputs

Power Supply Terminals 11+, 12- or Power RailNominal voltage 9-30 VDC (unregulated acceptable)Power consumption ≤ 2.5 W, 1.8 W typicalInrush current ≤ 300 mA

Input Terminals 1, 2 and 3Type 3-wire RTDsInput protection withstand ±5 VDCExcitation current:Pt100, Pt500, Pt1000 < 2 mANi120, Cu100, NiFe604 < 2 mACu10 < 10 mALead resistance 40% of base sensor resistance or

100 Ω (whichever is less) max. per lead

Output Terminals 4, 5 and 6; 7, 8 and 9Type 2 SPDT (Form C) relaysCurrent rating (resistive loads) 120 VAC @ 5 A

240 VAC @ 2 A28 VDC @ 5 A

Mechanical life ≥ 107 operationsRepeatability (constant temp.) 0.2% of full scaleLimit differentials (deadbands) 1-5% of spanTemperature drift ±0.05% of full scale / ºC (max.)Common mode rejection DC to 60 Hz: 120 dBIsolation 3-way 1,800 VDC

Response timeDynamic deadband relay condition changes when proper

condition exists for 100 msNormal mode (analog filter) ≤ 400 ms, 200 ms typical

MechanicalHousing Makrolon KF style housing (see page 387)

Dimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature 0ºC to +55ºC (+32ºF to +131ºF)

RTD Input2 Form C ContactOutputs Isolator

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

KFDA-RTD

DC Power Supply

11 (+) 12 (– )

7 8 9

Output B 4 5 6

Output A

(– ) 2 (R) 3

(+) 1 RTD Input

Page 36: 2002 IS Catalog - Steven Engineeringstevenengineering.com/Tech_Support/PDFs/32ISIGNAL.pdf · 2002 IS Catalog 138 Pepperl+Fuchs® ... KFD0-CC-1 (Current converter / single channel

173

Technical Data

Connection Diagram

Model Number

2002 IS Catalog

Pepperl+Fuchs® Inc. • Telephone (330) 486-0002 • FAX (330) 425-4607E-mail: [email protected] • www.am.pepperl-fuchs.com

Sig

nal C

onditio

ners

Universal Input 2 Form CContact Output / PCInterface Isolator

The KFD2-GU-1 universal input limit alarm isfield-configurable for 0-10 V, 0-20 mA, Pt100/Ni100 and all thermocouple inputs with three-way galvanic isolation. This unit also featuresinternal/external cold junction compensation(CJC) and burnout detection for thermocouplesand lead short circuit monitoring for RTDs andcurrent/voltage inputs. Calibration, adjustmentsand monitoring are achieved through a serialinterface to a PC.

All parameters are programmable through a K-ADP1 cable (sold separately) that provides theconnection between the programmingreceptacle of the KFD2-GU and the RS232 PCinterface.

Accessories include removable terminals withinternal cold junction compensation (K-CJC)and a K-SK programming software kit. The K-ADP1 cable and K-SK software kit are requiredunless the KFD2-GU is configured by P+F.

This unit is not intrinsically safe.

KFD2-GU-1

Universal temperature input

Programming & calibration via PC

3-way isolation

CJC for thermocouples and leadresistance compensation for RTDs

Power Supply Terminals 14+, 15- or Power RailNominal voltage 20-35 VDCMaximum voltage Um 40 VDCPower consumption 1.5 W

Input Terminals 1, 2, 3, 4, 5, 6Type Pt100, Ni100Thermocouple B,E,J,K,L,N,R,S or T

0-10 V, 0-20 mA, configuration withprogramming jack

Max. lead resistance ≤ 50 Ω per leadTest current 400 µA with RTDsNOTE: Switch off current for lead breakage monitoring during measurement

OutputOutput I (Limit 1) Terminals 7, 8 and 9Output II (Limit 2) Terminals 10, 11 and 12Contact load 253 VAC / 2 A / cos ø ≥ 0.6Mechanical life 2 x 107 operationsResponse time ≤ 370 msTemperature drift ±0.007% of switchpoint per ºC∆TPower ≤ 0.0035% of spanIsolation Galvanic isolation

MechanicalHousing Makrolon KF style housing (see page 387)

Dimensions (mm) 115 x 20 x 118Weight 100 g (3.5 oz.)Protection (IEC) IP20

Operating Temperature -20ºC to +60ºC (-4ºF to +140ºF)

Note: For information about programming,refer to our website at www.am.pepperl-fuchs.com

Sig

nal P

roce

ssor

KFD2-GU-1

11 (+) 12 (– )

7 8 9

Output 1

10 11 12

Output 2

DC Power Supply

(+) 6 (+) 5

(+) 4 (+) 3 (– ) 1 (– ) 2

(– ) 2 (– ) 2 (– ) 2

(– ) 1

(+) 3 (+) 3 (+) 3

(+) 4CJC Type K-CJC-GN

(+) 5

(– ) 2 (– ) 2 (– ) 2

(+) 6

(+) 1

(– ) 1

PC

K-ADPI