2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and...

30
2001, 2002 2001, 2002 & 3012 Series & 3012 Series Operation Operation (See Installation and Operation Manual for detailed instructions)

Transcript of 2001, 2002 & 3012 Series Operation 2001, 2002 & 3012 Series Operation (See Installation and...

2001, 20022001, 2002& 3012 Series& 3012 Series

OperationOperation(See Installation and Operation Manual for detailed instructions)

2

WaterTank

WaterPump

MultipleDischarges

2000 Series

Line Strainer

FoamTank

Electronic DirectElectronic DirectInjection ProportionerInjection Proportioner

Check Valves

FlowMeter

3

WaterTank

WaterPump

Flowmeter

Line Strainer

FoamTank

Electronic DirectElectronic DirectInjection ProportionerInjection Proportioner

Check Valves

MultipleDischarges

3012 Model

4

• Digital display reads “Hypro” upon initial power-up

• System then enters flow mode in standby– Operates as flowmeter

Digital Display OperationDigital Display Operation

5

• Push red “FOAM” button to arm system– “ON” light illuminates

• Open foam discharge– Displays solution volume– “ON” light blinks when foam

pump runs

Digital Display OperationDigital Display Operation

6

• Water flow display

• Push “SELECT” button and total volume of water discharged is displayed– Gallons, liters, imperial

gallons

Digital Display OperationDigital Display Operation

7

• Push “SELECT” button to enter “%” mode– Displays default injection

percentage– “PA” Single tank system

– “PC” Remote start/stop

(“UP” or “DOWN” button will override default setting)

Digital Display OperationDigital Display Operation

8

Digital Display OperationDigital Display Operation

• Push “SELECT” button to enter “TOTAL FOAM”– Displays total concentrate

injected

• Dual-tank mode– Totals for each tank– Display corresponds to tank

chosen by dual-tank valve

9

Digital Display OperationDigital Display Operation

• Enter “INJECTION PERCENTAGE” from any mode– Press either “UP” or “DOWN”

button momentarily to display current percentage setting

– Hold either button for two seconds to change setting accordingly

10

Operating Instructions Operating Instructions System ResetSystem Reset

Total Water %(Percent) Total Foam

• Reset these modes to 0 or % to default setting• Push both the up and down buttons in desired mode

11

Size Max Accuracy Max OperatingTee Flow Range Flow Range1-1/2x1" 5 - 110 gpm 3 - 145 gpm

1-1/2" 10 - 320 gpm 3 - 380 gpm

2" 15 - 520 gpm 5 - 625 gpm

2-1/2" 20 - 750 gpm 8 - 900 gpm

3" 30 -1150 gpm 12-1380 gpm

4" 55 -1980 gpm 20 -2380 gpm

FlowmeterFlowmeter

• No flow restrictions• Wide operating range

Safety FeaturesSafety Features

13

• When Lo con is Displayed

– Selected foam concentrate tank is getting low

– If foam concentrate is added within 2 minutes Lo con goes out

– If no foam concentrate is added within 2 minutes no con is displayed

• When no con is Displayed

– Foam concentrate pump will not run

– Add foam concentrate until no con display goes out then push Red Foam button to start the foam pump

Low Foam DisplayLow Foam Display

14

Exceeding Foam Injection RateExceeding Foam Injection Rate

• Hi Flo display– Occurs when the water flow and

selected foam concentrate injection percentage exceeds the foam pump capabilities

– Informs pump operator when this situation occurs

– Lower the foam concentrate injection percentage or water flow to stop the flashing Hi Flo display

15

Motor DriverMotor Driver

• Module controls pump motor

• Totally enclosed environmentally sealed

• Incorporates system circuit breaker

16

Digital Display OperationDigital Display Operation

• Simulated flow– While in “FLOW” mode, push

both lower buttons simultaneously

– Three bars on left indicate manual mode

– Pushing red “FOAM” button will turn foam pump on/off

– Pump injects to simulated flow default setting

17

System Air PurgeSystem Air Purge

• Enter “SIMULATED FLOW”

• Turn injection valve from “INJECT” to “CAL/FLUSH”

• Push red “FOAM” button on display to start foam pump

18

System Air Purge System Air Purge (cont.)(cont.)

• Run until concentrate flows steady out of dump line

• Push red “FOAM” button to stop pump

• Turn injection valve to “INJECT”

• Exit “SIMULATED FLOW”

System MaintenanceSystem Maintenance

20

2000 Series Foam Pump2000 Series Foam Pump

• Totally enclosed environmentally sealed motor

• Housing incorporates speed sensor

• Positive displacement plunger pump– Components made of

corrosion resistant materials

– Max operating pressure is 400 psi

21

3012 Foam Pump3012 Foam Pump

• Hydraulic motor• Housing incorporates

speed sensor• Positive displacement

plunger pump– Components made of

corrosion resistant materials

– Max operating pressure is 400 psi

22

System MaintenanceSystem Maintenance

• Clean strainer(s) regularly– Purge pump to remove

air pockets afterwards

• Check oil level– Dip stick reading

or– Sight glass

Concentrate Management SystemsConcentrate Management Systems

24

Foam TankA

Foam TankB

Manual CMSManual CMS

25

Foam TankB

Electronic CMSElectronic CMS

Foam TankA

26

Digital Display OperationDigital Display Operation

• Dual-tank function– Dual-tank valve in “A”– Displays “PA” and default

setting

– Dual-tank valve in “B”– Displays “Pb” and default

setting

• Default settings from 0.1 to 6.0%

27

Dual Foam Concentrate Tank (CMS)Dual Foam Concentrate Tank (CMS)

28

Dual-Tank FlushDual-Tank Flush

• System does not require flushing after Class A foam use– Turn off and flush hose

• Flush after using Class B foam– Flow water and engage

foam system– Turn manual valve to

“FLUSH” or electric valve to “OFF”

(“Off” position is a constant flush)

MultiFlo InterfaceMultiFlo Interface

30

MultiFlo InterfaceMultiFlo Interface

Std. Controller or AFC

MultiFloDisplay

ControlCable

FlowmeterCable

Flowmeter

Flowmeter

Flowmeter

Flowmeter