20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
85 years Triaxial test procedure - 20 years CoMeT
Different designs of Triaxial Cells
Cell 1000/300/300
Cell 1000/150/150
Cell 140/140/100
Cell 280/140/100
Cell 750/250/250
Test headclamp
2
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
Triaxial procedure - 1932 – 1971
1932 - Schelkunoff, (probably) first mention of the concept of Transfer impedance for cable screens
1936 - Ochem, H.: Der Kopplungswiderstand koaxialer Leitungen-Hochfrequenztechnik Elektroakustik 48 (1936) 251–259, (probably) first German description of the Transfer impedance .
The book of Kaden (only in German)1950 (1959) - Heinrich Kaden, Die elektromagnetische Schirmung in der Fernmelde- und Hochfrequenztechnik-(Wirbelströme und Schirmung in der Nachrichtentechnik – eddy currents and screening in telecommunications technology)Heinrich Kaden describes electromagnetic characteristics of cables and components.
Aalto University, Helsinki
3
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1961 – Triaxial test procedure up to 7,5 GHz
John Zorzy, R.F. Mühlenberger, RF Leakage Characteristics of popular Coaxial Cables and Connectors, 500 MC to 7.5 GC
Triaxial test procedure 1961, with sliding wall resp. movable short circuit
[MIL-PRF-39012E]
4
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
Literature 1956 – 1971
1956 - L. Krügel, Abschirmwirkung von Außenleitern flexibler Koaxialkabel, Telefunken-Ztg. 29 (1956) S. 5 – 13
1956 - Heinz Jungfer, Die Messung des Kopplungswiderstandes von Kabelabschirmungen bei hohen Frequenzen, NTZ 1956 Heft 12
1968 - Erich Homann, Geschirmte Kabel mit optimalen Geflechten, NTZ 1969 Heft 3 S. 155 - 161
1969 - Meyer de Stadelhofen describes the absorbing clamp, Techn.Mitt. PTT 1969.
1971 IEC 96-1 (Third Edition), Subclause A5.2, Transfer impedance due to resistive and magnetic coupling & Subclause A5.3, Transfer admittance due to electric coupling -Triaxial test procedures for Transfer impedance and Capacitive coupling, often mentioned or cited,Absorbing clamp procedure and injection wire procedure are not described at this time in IEC standards.(the same applies for IEC 96-1 - 1986 (Fourth Edition). 1956 - L. Krügel
5
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1975 – 1983 – Absorbing clamp procedure
1975 - CISPR 8, Report No. 47, Measurement of the shielding efficiency of coaxial cables having 1 or 2 braids in the metric wavelength range (1973), - Description of the absorbing clamp procedure and procedures with antennas to measure Screening attenuation
1983 - DIN 47250 Teil 6, Messung des Schirmungsmaßes koaxialer Kabel zwischen 30 und 1000 MHz, Verfahren mit Absorberzangen, Spatz, Hildebrand, Ditscheid et. al. DKE-UK 412.3
1983 (Januar) – first CATV networks in Germanypilot tests in Ludwigshafen, Dortmund, Munich, Berlin
6
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
The “ready for cable TV“ room antenna
ready for cable TV
The “ready for cable TV“ room antenna causes the German telecom to tighten their networks.At first 75 dB screening attenuation up to 1 GHz were required.In 2000, screening classes according to EN 50117 were introduced, e.g. Class A with 85 dB to 1 GHz
neighbourscable
7
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1985 – first computer controlled test station with NWA
1985 – start at bedea, establish a test station to measure screening attenuation with Computer und Netzworkanalyser R&S ZVB (with narrow RF bandwith)
first computer controlled test station to measure screening attenuation - with R&S ZPV VNA(also the first of its kind), up to this time, screening eff. was measured only with measuring receivers
R&S ZPV
MDS 21, 30 MHz up to 1 GHz and MDS 22, 500 MHz up to 2400 MHz
8
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1987 - summingfunction - coupling transfer function
1987 - Lauri Halme/Balint Szentkuti, Background of electromagnetic screening, Introduction of the Summing function and the Coupling transfer function, Lauri Halme Convenor of IEC 46A/WG1 Screening effectiveness (now IEC TC 46/WG 5), Balint Szentkuti Secretary of IEC 46A/WG1
The basis for IEC 62153-4-4 what are 6 dB between friends ?!
9
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1988 – 1993 - “line injection”- procedure
1988 - Bernhard Eicher, Christian Staeger & Balint Szentkuti, PTT Berne & Heinz Fahrni, Solothurn, Simple and accurate screening measurements on RF-cables up to 3 GHzDescription of the “line injection”- procedure
IEC 96-1Amd2 – 1993-03, line injection- procedure and absorbing clamp procedure standardized
Speisedrahtverfahren, Aufbau von G. Quednau
10
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1990 – 1993 – Otto Breitenbach1990 my first inernational standardisation meeting, IEC SC 46A in Helsinki,Chairman J. A. Osterfield, Sekretary K.A. Ridley, Lauri Halme with first mobile, phones with Paris.
1990 - Otto Breitenbach provides triaxial procedure for screening attenuation at DKE-UK 412.3.
1993 - Breitenbach, O., Hähner T.: Kabelschirmung im Übergang von MHz- zu GHz-Frequenzen. ntz Bd.46(1993) H.8, S. 602-608, Triaxial-procedure to measure Screening attenuation in ntz.
1998-01 - IEE Colloquium in London - Breitenbach/Hähner/Mund - Screening of Cables in the MHz to GHz Frequency Range, Extended Application of a Simple Measuring Method (Bernd Rosenberger was also present)
11
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
as/[d
B]
ZT
/[mO
hm/m
Transfer impedance
screeningattenuation
Transfer impedance and screening attenuation
12
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1994-01 – NWP - 46A(Germany)62 - NP
46A(Germany)62 New work item proposal for screening attenuation aS
triaxial up to 3 GHz
Proposal to measure Screening attenuation with Triaxial procedure submitted to IEC TC 46
13
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1994 – 1995 – IEC 1196
1994 - AK Schirmung und Mikrofonie in Asslar, Breitenbach, Hähner, Spatz; Halme, NeuhausChaos at the Lokschuppen in Asslar
1995-05 - IEC 1196-1, RF cables Part 1, Generic specification – General, definition, requirements and test methods – Transfer impedance with Triaxial procedure and with line injection procedure. 1995 – Chairman of UK 412.3, Koaxiale Kabel
Test set-up with damping resistor,feeding via Test head
IEC 1196-1 completely revised,46A(CO)159Triaxial procedure for aS is still missing
14
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1996 – 1997 – first Contact with RB
1996 - Christof Merz, report from praktika at bedea test laboratory, 50 Ohm from sleeveThis makes it possible to clarify various objections to IEC TC 46/WG 5
1997 – Diploma work Roland Herrmann, with coupling attenuation triaxial, among others
1997-09 – First visit at Rosenberger(together with Roland Herrmann),The first 6 CoMeT-s are built, still with screw connection, Later comes the "klack-wau"wait onother 5 Minutes !
Eberhard Rodig keeps the bedea Prototyp provisionally in Fridolfing, Roland Herrmann also stays at RB later
CoMeTProto-Types
15
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1997 - CoMeT Prototypes
bedeaRF- & EMC-laboratories
16
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1997 – Design drawing in Eberhard's “Laborbook”
17
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1997 – everything is blue
acc. to Eberhard Rodig, (who was born in Dresden)the blue colour is a memory on “Meißner Porzellan“ Foto: wikipedia
18
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1998 – first CoMeT delivery
1998 – first CoMeT delivery by RB(The first three CoMeT-s were picked up)
Eberhard makes the student “Light to the bicycle” (Thomas Völker)
second visit at Rosenbergertubes are not black and made from brassbut blue and made from Aluminium -and the RG 058 is hanging slagged.
first CoMeT customers weredas VDE Test und Certification Institutin Offenbachand the “Fernmeldetechnisches Zentralamt” (FTZ) in Darmstadt (Telecommunications Central Office)
19
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1998 – Houston
1998 - IEC General meeting in Houston, Texas, Presentation of CoMeT to IEC TC 46
Eberhard builds the "flyer", Achim Fabry "drags" a Ballman VNA to Houston
the "flyer" Thomas Hähner, Joe Walling, Achim Fabry
20
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1998 – IEC General meeting in Houston
1998 - IEC General meeting in Houston, Texas, Presentation of CoMeT to IEC TC 46
Eberhard builds the "flyer", Achim Fabry "drags" a Ballman VNA to Houston
21
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
1999 – done !!!
IEC 61196-1Amd1: 12.6 Shielded screening attenuation test method for measuring the screening attenuation aS up to and above 3 GHz ( )
( )02123
0212
0211
/4
/2
/2
λεπϕϕϕ
λεεπϕ
λεεπϕ
l
l
l
r
rr
rr
=−=
+=
−=
[ ] [ ]
( ) ( )
U
U
Z Ze
Z Ze
Z
c
Z R e
T F
r r
j T F
r r
j
j
2
1 1 2 1 2 1
0
2
1 11
2 1 1
1 2
3
≈−−
⋅ − +++
⋅ − ⋅⋅
⋅
+ − ⋅ −
− −
−
ε ε ε ε ωϕ ϕ
ϕ/
test method for measuring the screening attenuation aS up to and above 3 GHz standardized at IEC 61196-1 !!
i.e. formally | A + B | ⋅C⋅D, where AC is the far end crosstalk, BC is the reflected near end crosstalk and D is the mismatch factor
22
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2000 - Coupling attenuation
2000 - TC 46 meeting in Ischia, WG 5 works on a procedure to measure coupling attenuation with triaxial test pocedure
Note (1996): IEC TC 46/WG 5 meeting in Nürnbergmeasuring the screening effectivenessof unscreened pairs with triaxial test procedure
looking for field strength with Lauri Halme(was switche of for Finland, due to problems with roaming fees.
T. Hähner designs the “open head“
ferrite-absorber
remaining cable length, appr. 97m
receiver
tube with open head
cable under test
generator
housing balun balanced/unbalanced load
pick-up wire
IEC 62153-4-9Ed1, Coupling attenuation with triaxial test pocedure with open test head
23
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
Screening classes acc. to EN 50117 & IEC 61196
Schirmungs-Klasse 5 - 30 MHz 30 -1000 MHz 1 GHz – 2 GHz 2 GHz – 3 GHz
C 50 mOhm/m 75 dB 65 dB 55 dB
B 15 mOhm/m 75 dB 65 dB 55 dB
A 5 mOhm/m 85 dB 75 dB 65 dB
A+ 2,5 mOhm/m 95 dB 85 dB 75 dB
A++ 0.9 mOhm/m 105 dB 95 dB 85 dB
2002 – Secretary at CLC SC 46XA – (kommisarisch ab 2000) with Guy Perrot as Chairman
Introduction of screening classes into the standards of EN 50117 series (CATV cables)
acc. to EN 50117 Screening effectiveness shall only be maesured with Triaxial procedure!
2002-03 - EN 50289-1-6, Communication cables – Specifications for test methodsPart 1-6: Electrical test methods – Electromagnetic performance. Transfer impedance: Triaxial & wire injection, Screening attenuation: Triaxial & Clamp procedure.
2004-01 - Secretary of IEC SC 46A (with Lauri Hame as Chairman), also provisional work for TC 46 and of TC 46/WG 5, (IEC 62153-4-3 und -4-4 are in progress).
24
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2002 – 2004 – Tube in tube
2002 - Tube in tube –Lauri Halme sketches the draft for tube in tube method on a napkin during emc düsseldorf.2004 - B. Mund, Tube in tube – procedure - IWCS presentation, Philadelphia, USA
2006-04 - IEC 62153-4-7Ed1, Test method for measuring the transfer impedance and the screening or the coupling attenuation –Tube in tube method
2003-08 – Roland Reimann overtakes the development of the WinCoMeT - SoftwareMS-DOS Version Delphi
25
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2004 – CoMeT 18
2004 – CoMeT 18, C. Pfeiler wants to measure 9 GHz, according to the equation
the cut off frequency should be at 9 GHz, but the CoMeT 18 works up to 18 (20 GHz)
2005 - Diplomanwork Ballier, - Influence of higher order modes -CoMeT 40 with “Mode screw“ – CoMeT 40 with modified test head now up to 12 GHz
( )dDHg +=
211
πλ
for the H11-wave:
dDEg −=
01λ
for the E01-wave
The H11-wave does not occur at a (exact) cylinder symmetrical set-up.
( )dD
cf
r
g +⋅⋅
=1
02
επ
26
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2005 – 2006 – IEC 62153er Serie - CoMeT K
2005 – Michael Wollitzer proposes procedure for emc gaskets and feedthroughs
2006-03 - IEC 62153-4-3Ed1, Surface Transfer impedance – Triaxial method2006-03 - IEC 62153-4-4Ed1, Shielded Screening attenuation test method for measuring of the as up to and above 3 GHzTransfer impedance and Screening attenuation , -Triaxial procedure standardized at 62153-4er series !
2009-05 - IEC 62153-4-10Ed1 –Screening effectiveness of feed throughs and EMC gaskets, Double-Coaxial Procedure
Günther Quednau developed independently, parallel to this a similar test procedure, the standard was already finished
Die EMC – Test procedures of IEC 96-1are describe resp. standardized now in IEC 62153-4-n series
CoMeT K
27
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2006 - 100 years IEC
2006-08 - IEC General meeting Berlin, 100 Jahre IEC, Thomas Schmid demonstrates the measurement of EMC gaskets and feedthroughs, IEC 62153-4-10
28
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2010 – Triaxial Cell
2010 – First Triaxial Cell: Citation: “If that is for the car industry, Mr Rodig, then do it“
The trigger for the first Triaxial cell was an HV connection cable for electric vehicles
29
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2010 – 2015 – Angled test head – Triaxial Cell
2015-12 - IEC 62153-4-15Ed1 –Transfer impedance and Screening attenuation with “Triaxiale Cell”(Ed2 ist in preparation)
Problem: low results, if Z2 < Z1
and low cut off frequency resp. higher order modes
(Cell becomes a wvwguide resp. a cavity)
The “Angled test head”becomes Triaxial Cell
the “klack-wau“
30
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2013 - Changes of IEC 62153-4-3Ed2, Transfer impedance
Procedure A:Matched inner circuit with damping resistor in outer circuit R2
( ) ⎪⎪
⎭
⎪⎪
⎬
⎫
⎪⎪
⎩
⎪⎪
⎨
⎧⎟⎟⎠
⎞⎜⎜⎝
⎛⎟⎟⎠
⎞⎜⎜⎝
⎛+−−
−
+=
20
log10
c0
201T
010padcalmeas
10
CUTZ
Zaaa
LZ
RZRZ
⎭⎬⎫
⎩⎨⎧ −
−⋅
⋅+
= 20
c
01T
calmeas
102
aa
L
ZRZ
⎭⎬⎫
⎩⎨⎧ −
−⋅
⋅= 20
c
0T
calmeas
102
aa
L
ZZ
Procedure B: Inner circuit with load resistor and outer circuit without damping resistor
Procedure C:(Mismatched)-Short-Short without damping resistor
mismatched –matched– short
matched – matched – short
mismatched – short – short
31
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2014 – ZVEI Satellit & Kabel – Warning of the Triaxial Cell
Conclusion: Due to the different problem areas described above, the ZVEI Satellite & Cable Divisionconsiders the introduction of the „Triaxial Cell“ measuring method as not suitable as a measurement method for passive components and devices. The “Triaxial Cell” measuring method offers no benefits, rather the expected measurement uncertainties and higher measurement efforts associated with the measurement process lead to an unacceptable deterioration in results achieved in comparison to the proven “Absorber Clamp” measuring method..
Fachverband Satellit & Kabel(Professional association Satellite & Cable)
Problems actually exist when the characteristic impedance in the outer system is smaller than the input resistance of the receiver is (Z2 < Z1), as well as by the cut off frequency or by higher modes and resonances (Cell becomes a waveguide or the cavity), see Ismar Lucicanin, David Pouhè, et. al. - Higher Order Mode Suppression in Triaxial Cells, Proceedings of the 65nd IWCS Conference, Providence, RI, USA, pp 133 – 139, October 2016
Further open questions are discussed and solved in cooperation with IEC TC 46 / WG 5.
2014 - CoMeT_System resp. Triaxial Cell presented at CENELEC TC 209as an alternative to the test methods of EN 50083-2
32
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2014 – Triaxial cell with tube in tube and sliding wall
33
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
2016 - Triaxial “Absorber“ - Cell
Cell 140/140/100device under test
with hole
hole appr. 3mm
Although other absorber material like ferrites or nanocrystalline absorbers could be useful, measurementswere performed with magnetic absorbers due to the good mechanical characteristics and easy handling.
magnetic absorber
magnetic Absorber
34
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
Triaxial Cell with magnetic absorber
IEC 62153-4-15, Transfer impedance and Screening attenuation with Triaxial Cellwill be revised accordingly by IEC TC 46/WG 5
Higher order modes can be easily suppressed by using absorbing materialslike ferrite tiles or by nanocrystalline or by magnetic absorbers placed in the Cell
generator DUT receiver
tube in tube
connecting cable
test head with screening cap
Triaxial Cell
magnetic absorber
35
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
Coupling attenuation up to 2 GHz with virtual Balun
Generator
DUT
tube (CoMeT 40) balanced/ unbalanced load
receiver
screening cap
Generator
connecting device
generator
ferrite-absorber
receiver
tube with open head
screen under test
generator
housing connecting device
load
remaining cable length, appr. 97m
Open test head
Standard test head
36
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
International Standards for Triaxial test procedures
TS 62153-4-1 Introduction to electromagnetic (EMC) screening measurements
2014-01 published
62153-4-3Ed2 Surface transfer impedance - Triaxial method 2013-10 published
62153-4-4Ed2 Shielded screening attenuation, test method for measuring of the screening attenuation aS up to and above 3 GHz
2015-04 published
62153-4-7Ed2 Shielded screening attenuation test method for measuring the Transfer impedance ZT and the screening attenuation aS or the coupling attenuation aC of RF-Connectors and assemblies up to and above 3 GHz, Tube in tube method
2015-12
published
62153-4-9 Electromagnetic Compatibility (EMC) – Coupling attenuation, triaxial method
2017-05 46/642/CDV
62153-4-10Ed2 Shielded screening attenuation test method for measuring the Screening Effectiveness of Feedtroughs and Electromagnetic Gaskets
2015-11 published
62153-4-15 Test method for measuring transfer impedance and screening attenuation - or coupling attenuation with Triaxial Cell
2015-12 Revision in preparation
62153-4-16 Relationship between surface transfer impedance and screening attenuation, Conversion aS and ZT
2016-08 46/615/FDIS
37
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
The CoMeT success story continues
2022 - 25 Jahre CoMeT(E. Rodig gets the CoMeT in Platin)
2025 - 500 CoMeT-systems sold
2037 - 40 years CoMeT
2047 - 50 years CoMeT
the next 20 years of CoMeT:
unscreened pairs/quads
active components
reference prodedure………………….
……………………
38
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
www.bedea.com
Thanks for listening
? ? ?
39
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
Standardization – 1985
40
20 years CoMeT resp. 20 years bedea-Rosenberger, 06./07. July 2017
Bernhard Mund, bedea Berkenhoff&Drebes GmbH, Herborner Straße 100, 35614 Asslar, Germany, [email protected], www.bedea.com
bedea
Standardization - today