2
NPP-E05-11 Series PFM 2-color Display Digital Flow Switch Straight piping length 48 241.6 88 67 43 116 18 34 68 Flow rate range: 10, 25, 50, 100 l /min Min. flow measurement: 0.01 l /min (0.1 l /min when the flow rate range is 25, 50, 100 l /min.) Fluid: Air, N2, Ar, CO2 Accuracy (linearity): 3 % F.S. Grease-free Flow adjustment valve is integrated. (Reduced piping and space saving) Response time: Either 50 msec, 0.5 sec, 1 sec or 2 sec can be chosen. + Piping space can be reduced. Mountable in a narrow location since the straight piping length is not required. A straight piping length of 8 times the piping diameter is required for the conventional model. Compact size (Same size even when the different flow rate model is chosen.) Comparison with the conventional model PF2A711 (10-100 l /min) when ø6 One-touch fittings are attached. Comparison with the conventional model PF2A711 (10 to 100 l/min) 2-color display 2-color Display Digital Flow Switch 2-color display Irregular value at a glance Flow adjustment valve Light weight: 55 g ( PFM711 ) Conventional model PF2A711: 290 g

Transcript of 2-color Display Digital Flow Switch · 2-color Display Digital Flow Switch Straight piping length...

Page 1: 2-color Display Digital Flow Switch · 2-color Display Digital Flow Switch Straight piping length 48 241.6 88 67 43 116 34 18 68 Flow rate range: 10, 25, 50, 100 l/min Fluid: Air,

NPP-E05-11

Series PFM

2-color Display Digital Flow Switch

Straight piping length48

241.6

88

67

43

116

1834

68

�Flow rate range:

10, 25, 50, 100 l /min

�Min. flow measurement: 0.01 l /min

(0.1 l /min when the flow rate range is 25, 50, 100 l /m

in.)

�Fluid: Air, N2, Ar, CO2

�Accuracy (linearity): 3 % F.S.

�Grease-free

�Flow adjustment valve is integrated.

(Reduced piping and space saving)

�Response time: Either 50 msec,

0.5 sec, 1 sec or 2 sec can be chosen. + –

Piping space can be reduced.Mountable in a narrow location since the straight piping length� is not required.

� A straight piping length of 8 times the piping diameter is required for the conventional model.

Compact size(Same size even when the different flow rate model is chosen.)

Comparison with the conventional model PF2A711 (10-100 l /min)when ø6 One-touch fittings are attached.

Comparison with the conventional model PF2A711 (10 to 100 l/min)

2-color display2-color Display Digital Flow Switch

2-color displayIrregular value at a glance

Flow adjustment valve

Light weight: 55 g(PFM711)

Conventional model PF2A711: 290 g

Page 2: 2-color Display Digital Flow Switch · 2-color Display Digital Flow Switch Straight piping length 48 241.6 88 67 43 116 34 18 68 Flow rate range: 10, 25, 50, 100 l/min Fluid: Air,

� Mounting methods � Several combinations are possible. Depending on the installation conditions, it is possible to add or remove the flow adjustment valve, change the fitting type and the piping direction as desired.

• 2 NPN or PNP outputs

• 1 NPN or PNP output + Analog (1 to 5 V)

• 1 NPN or PNP output + Analog (4 to 20 mA)

• 1 NPN or PNP output + External input

Output Specifications

Clip

One-touch fitting

Flow adjustment valve

Female thread

12

S

IN

1 2S

IN

1

2S

IN

1 2S

IN

1

12

1

S

IN

One-touch Fittings ø4, ø6, ø8, ø1/4

Female thread Rc 1/8, 1/4 · NPT 1/8, 1/4 · G 1/8, 1/4

12

S

IN

1 2S

1

1 2S

IN

1

Wit

ho

ut

flo

w a

dju

stm

ent

Wit

hfl

ow

ad

just

men

t

� Piping Variation

PFM710

PFM725

PFM750

PFM711

0.2 to 10 (0.2 to 5)

0.5 to 25 (0.5 to 12.5)

1 to 50 (1 to 25)

2 to 100 (2 to 50)

Series Flow rate range l /min

Flow Rate Range

( ): in the case of CO2

Comparison with Float Type Flow Meter Series PFM

Digital display

Display

Float Type Flow Meter

Not subject to pressurevariations.

Pressure fluctuation

Subject to pressure variations. (The outlet side is open.)

Not restricted

Switch output, Analog output

Mounting orientation

Output

Accumulatedflow rate display

Vertical with flow direction from bottom to top

No output

Not displayableDisplayable

Able to confirm the total air consumption per day

Both of these flow meters display the same value even though fluid pressure differs before and after the regulator.

The displayed value will change before and after the regulator, even though the flow rate is the same.

If located here, the correct value is obtained. (Conversion is required.)

Released to atmosphere

Output Specifications

Flow Rate Range Comparison with Float Type Flow Meter

Panel mount

Bracket

DIN rail

Visual check (Can be misread depending on the angle)

1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659 JAPANTel: 03-3502-2740 Fax: 03-3508-2480URL http://www.smcworld.com© 2005 SMC Corporation All Rights Reserved

Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.

1st printing JY printing JY 130KS Printed in Japan.D-KS

This catalog is printed on recycled paper with concern for the global environment.