1D-1 PCB ANALYSIS DATA SHEETConc. Extract Volume: Injection Volume: SDG No: Lab Sample ID: Lab File...

1075
Pace Analytical Services, Inc. 1D-1 AP17506 Laboratory Name: ELAP ID No: Matrix: Sample wt(Dry)/vol: Percent Moisture: Conc. Extract Volume: Injection Volume: SDG No: Lab Sample ID: Lab File ID: Date Received: Date Extracted: Date Analyzed: Dilution Factor: CAS NO COMPOUND NAME CONCENTRATION Q Method: Sulfur Cleanup: Extraction: SL-17-071112-006 11078 12070226 Polyurethane Foam N/A GC20F-1324-16 07/12/2012 07/12/2012 07/13/2012 1 N/A Soxhlet Method (3540C) 5000 uL 1.0 uL EPA Method TO-4A YES UG GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 μm Client ID: LRF ID: 12070226-09 Column 1 Information: Injection Volume: Lab File ID: GC20B-1313-16 1.0 uL GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 μm Column 2 Information: Number Column PCB ANALYSIS DATA SHEET 12674-11-2 Aroclor 1016 0.100 U 1 11104-28-2 Aroclor 1221 0.547 PB 1 11141-16-5 Aroclor 1232 0.100 U 1 53469-21-9 Aroclor 1242 0.497 PD 1 12672-29-6 Aroclor 1248 0.100 U 1 11097-69-1 Aroclor 1254 0.408 AF 1 11096-82-5 Aroclor 1260 0.100 U 1 Laboratory Qualifiers: AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern. PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accurately quantify PCB present in sample that has undergone environmental alteration. PD-Aroclor 1242 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1242 is not present in the sample, but is reported to more accurately quantify PCB present in sample that has undergone environmental alteration. Note: There were several non-target peaks. U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilution factors. Lims Version : 5.0.6.6 FORM I-CLP-PCB Print Date: 7/17/2012

Transcript of 1D-1 PCB ANALYSIS DATA SHEETConc. Extract Volume: Injection Volume: SDG No: Lab Sample ID: Lab File...

  • Pace Analytical Services, Inc.

    1D-1

    AP17506

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    SL-17-071112-006

    11078

    12070226

    Polyurethane Foam

    N/A

    GC20F-1324-16

    07/12/2012

    07/12/2012

    07/13/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070226-09

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1313-16

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.547 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.497 PD112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.408 AF111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PD-Aroclor 1242 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1242 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17507

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    BK-5-071112-008

    11078

    12070226

    Polyurethane Foam

    N/A

    GC20F-1324-17

    07/12/2012

    07/12/2012

    07/13/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070226-10

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1313-17

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.244 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.541 AF111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17508

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    FS-071112-062312-2

    11078

    12070226

    Polyurethane Foam

    N/A

    GC20F-1324-18

    07/12/2012

    07/12/2012

    07/13/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070226-11

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1313-18

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 1.05111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:Note: There were few non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP12679B

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    METHOD BLANK

    11078

    12060396

    Solvent

    N/AGC10F-415-33

    06/22/2012

    06/26/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    Client ID:

    LRF ID: PBLK-66

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 0.100 U

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP13253B

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    METHOD BLANK

    11078

    12060435

    Solvent

    N/AGC10F-415-38

    06/23/2012

    06/26/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    Client ID:

    LRF ID: PBLK-88

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 0.100 U

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17498B

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    METHOD BLANK

    11078

    12070226

    Polyurethane Foam

    N/AGC20F-1324-4

    07/12/2012

    07/13/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: PBLK-57

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 0.100 U

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17498L

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    LAB CONTROL SPIKE

    11078

    12070226

    Polyurethane Foam

    N/AGC20F-1324-5

    07/12/2012

    07/13/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: LCS-57

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 1.06

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17498S

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    LAB CONTROL SPIKE DUPLICATE

    11078

    12070226

    Polyurethane Foam

    N/AGC20F-1324-6

    07/12/2012

    07/13/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: LCSD-57

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 1.05

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm

    SURR 1 (Col 1)

    LRF ID

    SURR 1

    Laboratory Name:Pace Analytical Services, Inc. SDG: 12060435

    GC Column (1):

    GC Column (2):

    TOTAL

    % REC # OUT

    2F-1PCB SURROGATE RECOVERY

    FILE ID

    ELAP ID No: 11078

    LABSAMPLE ID

    (Col 1)SURR 2

    % REC #

    SURR 2 (Col 2) (Col 2)

    % REC # % REC #

    LAB OTHER(1)

    OTHER(2)

    PBLK-88 86.6 95.0 0GC10F-415-38AP13253B

    PBLK-88 87.1 95.5 0GC10B-388-38AP13253B

    12060435-01 99.7 104 0GC10F-415-39AP13253

    12060435-01 98.4 105 0GC10B-388-39AP13253

    12060435-02 94.8 102 0GC10F-415-41AP13254

    12060435-02 93.9 99.3 0GC10B-388-41AP13254

    12060435-03 89.1 101 0GC10F-415-42AP13255

    12060435-03 89.8 103 0GC10B-388-42AP13255

    Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6

    Advisory QC Limits.

    # Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out

    SURR1 = TETRACHLORO-META-XYLENE

    SURR2 = DECACHLOROBIPHENYL (60.0-120)

    (60.0-120)

    Print Date: 7/17/2012

  • Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm

    SURR 1 (Col 1)

    LRF ID

    SURR 1

    Laboratory Name:Pace Analytical Services, Inc. SDG: 12060396

    GC Column (1):

    GC Column (2):

    TOTAL

    % REC # OUT

    2F-1PCB SURROGATE RECOVERY

    FILE ID

    ELAP ID No: 11078

    LABSAMPLE ID

    (Col 1)SURR 2

    % REC #

    SURR 2 (Col 2) (Col 2)

    % REC # % REC #

    LAB OTHER(1)

    OTHER(2)

    PBLK-66 86.8 94.9 0GC10F-415-33AP12679B

    PBLK-66 86.0 95.7 0GC10B-388-33AP12679B

    12060396-01 90.8 100 0GC10F-415-34AP12679

    12060396-01 93.1 100 0GC10B-388-34AP12679

    12060396-02 90.8 99.9 0GC10F-415-35AP12680

    12060396-02 93.0 100 0GC10B-388-35AP12680

    12060396-03 88.2 95.1 0GC10F-415-36AP12681

    12060396-03 88.2 95.2 0GC10B-388-36AP12681

    12060396-04 88.9 98.5 0GC10F-415-37AP12682

    12060396-04 90.1 99.8 0GC10B-388-37AP12682

    Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6

    Advisory QC Limits.

    # Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out

    SURR1 = TETRACHLORO-META-XYLENE

    SURR2 = DECACHLOROBIPHENYL (60.0-120)

    (60.0-120)

    Print Date: 7/17/2012

  • Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm

    SURR 1 (Col 1)

    LRF ID

    SURR 1

    Laboratory Name:Pace Analytical Services, Inc. SDG: 12070263

    GC Column (1):

    GC Column (2):

    TOTAL

    % REC # OUT

    2F-1PCB SURROGATE RECOVERY

    FILE ID

    ELAP ID No: 11078

    LABSAMPLE ID

    (Col 1)SURR 2

    % REC #

    SURR 2 (Col 2) (Col 2)

    % REC # % REC #

    LAB OTHER(1)

    OTHER(2)

    PBLK-72 83.9 96.9 0GC20F-1325-60AP17981B

    PBLK-72 87.6 99.6 0GC20B-1314-60AP17981B

    LCS-72 84.3 98.3 0GC20F-1325-61AP17981L

    LCS-72 89.9 103 0GC20B-1314-61AP17981L

    LCSD-72 82.3 96.3 0GC20F-1325-62AP17981S

    LCSD-72 84.9 98.7 0GC20B-1314-62AP17981S

    12070263-01 82.9 95.1 0GC20F-1325-63AP17981

    12070263-01 87.1 98.7 0GC20B-1314-63AP17981

    12070263-02 97.9 97.8 0GC20F-1325-64AP17982

    12070263-02 82.5 101 0GC20B-1314-64AP17982

    12070263-03 102 91.9 0GC20F-1325-65AP17983

    12070263-03 82.2 95.9 0GC20B-1314-65AP17983

    12070263-04RR1 71.9 D 46.2 D 0GC20F-1329-4AP17984RR1

    12070263-04RR1 70.4 D 73.1 D 0GC20B-1318-4AP17984RR1

    12070263-05 111 94.2 0GC20F-1325-67AP17985

    12070263-05 83.3 98.4 0GC20B-1314-67AP17985

    12070263-06 93.9 90.2 0GC20F-1325-68AP17986

    12070263-06 81.1 94.5 0GC20B-1314-68AP17986

    12070263-07 104 96.5 0GC20F-1325-70AP17987

    12070263-07 85.7 98.8 0GC20B-1314-70AP17987

    12070263-08 88.5 90.6 0GC20F-1325-71AP17988

    12070263-08 83.7 97.2 0GC20B-1314-71AP17988

    12070263-09 109 95.1 0GC20F-1325-72AP17989

    12070263-09 85.6 100 0GC20B-1314-72AP17989

    12070263-10 90.2 91.3 0GC20F-1325-73AP17990

    12070263-10 77.3 94.1 0GC20B-1314-73AP17990

    12070263-11 93.6 92.4 0GC20F-1325-74AP17991

    12070263-11 79.2 98.2 0GC20B-1314-74AP17991

    Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6

    Advisory QC Limits.

    # Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out

    SURR1 = TETRACHLORO-META-XYLENE

    SURR2 = DECACHLOROBIPHENYL (60.0-120)

    (60.0-120)

    Print Date: 7/19/2012

  • Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm

    SURR 1 (Col 1)

    LRF ID

    SURR 1

    Laboratory Name:Pace Analytical Services, Inc. SDG: 12070263

    GC Column (1):

    GC Column (2):

    TOTAL

    % REC # OUT

    2F-1PCB SURROGATE RECOVERY

    FILE ID

    ELAP ID No: 11078

    LABSAMPLE ID

    (Col 1)SURR 2

    % REC #

    SURR 2 (Col 2) (Col 2)

    % REC # % REC #

    LAB OTHER(1)

    OTHER(2)

    12070263-12 80.1 94.0 0GC20F-1325-75AP17992

    12070263-12 88.0 101 0GC20B-1314-75AP17992

    Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6

    Advisory QC Limits.

    # Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out

    SURR1 = TETRACHLORO-META-XYLENE

    SURR2 = DECACHLOROBIPHENYL (60.0-120)

    (60.0-120)

    Print Date: 7/19/2012

  • Laboratory Name:

    Method Blank File ID:

    ELAP ID No: SDG No:

    Pace Analytical Services, Inc.

    11078 12070263

    GC20F-1325-60LCS File ID: GC20F-1325-61

    3F-2 LABORATORY CONTROL SPIKE (LCS) RECOVERY

    LCS Lab ID: LCS-72 Blank Sample ID: PBLK-72

    07/14/2012 23:36:00

    AP17981LLCS ID:

    LCS Inj Date:

    Method Blank ID: AP17981B

    Method Blank Inj Date: 07/14/2012 23:23:26

    Polyurethane FoamLCS Matrix: Polyurethane FoamMethod Blank Matrix:

    COMPOUNDSPIKEADDED

    LCSCONCENTRATION

    LCSPERCENT

    RECOVERY #

    QC LIMITS

    RECOVERY

    PERCENT(ug) (ug)

    1

    Aroclor 1254 1.00 1.06 106 70.0-130

    # Column to be used to flag recovery values

    * Values outside of QC limits

    Spike Recovery: out of outside limits.0 1

    QC Limits based upon laboratory defaults.1

    COMMENTS:

    Form III-CLP-PCB (PACE)Lims Version : 5.0.6.6

  • Laboratory Name:

    Method Blank File ID:

    ELAP ID No: SDG No:

    Pace Analytical Services, Inc.

    11078 12070263

    GC20B-1314-60LCS File ID: GC20B-1314-61

    3F-2 LABORATORY CONTROL SPIKE (LCS) RECOVERY

    LCS Lab ID: LCS-72 Blank Sample ID: PBLK-72

    07/14/2012 23:36:05

    AP17981LLCS ID:

    LCS Inj Date:

    Method Blank ID: AP17981B

    Method Blank Inj Date: 07/14/2012 23:23:30

    Polyurethane FoamLCS Matrix: Polyurethane FoamMethod Blank Matrix:

    COMPOUNDSPIKEADDED

    LCSCONCENTRATION

    LCSPERCENT

    RECOVERY #

    QC LIMITS

    RECOVERY

    PERCENT(ug) (ug)

    1

    Aroclor 1254 1.00 1.08 108 70.0-130

    # Column to be used to flag recovery values

    * Values outside of QC limits

    Spike Recovery: out of outside limits.0 1

    QC Limits based upon laboratory defaults.1

    COMMENTS:

    Form III-CLP-PCB (PACE)Lims Version : 5.0.6.6

  • Laboratory Name:

    ELAP ID No: SDG No:

    Pace Analytical Services, Inc.

    11078 12070263

    LCS Lab File ID: GC20F-1325-61

    3F-1 PCB LAB CONTROL SAMPLE (LCS) / LAB CONTROL SAMPLE DUPLICATE (LCSD) RECOVERY

    LCS LRF ID: LCS-72

    07/14/2012 23:36:00

    AP17981LLCS Lab Sample ID:

    LCS Sample Inj Date:

    LCSD Lab File ID: GC20F-1325-62

    LCSD LRF ID: LCSD-72

    07/14/2012 23:48:35

    AP17981SLCSD Lab Sample ID:

    LCSD Sample Inj Date:

    COMPOUND

    SPIKEADDED

    LCSCONCENTRATION

    LCSPERCENT

    RECOVERY #

    QC LIMITS

    RECOVERY

    PERCENT(ug) (ug)

    1

    Aroclor 1254 1.00 1.06 106 (70.0-130)

    COMPOUNDSPIKEADDED CONCENTRATION

    LCSD LCSDPERCENT RPD #

    QC LIMITS

    RECRPD(ug) (ug)

    1

    RECOVERY #

    Aroclor 1254 1.00 1.07 107 0.939 20 (70.0-130)

    # Column to be used to flag recovery values

    * Values outside of QC limits

    Spike Recovery: out of outside limits.0 2

    QC Limits based upon laboratory defaults.1

    RPD: out of outside limits.0 1

    COMMENTS:

  • Laboratory Name:

    ELAP ID No: SDG No:

    Pace Analytical Services, Inc.

    11078 12070263

    LCS Lab File ID: GC20B-1314-61

    3F-1 PCB LAB CONTROL SAMPLE (LCS) / LAB CONTROL SAMPLE DUPLICATE (LCSD) RECOVERY

    LCS LRF ID: LCS-72

    07/14/2012 23:36:05

    AP17981LLCS Lab Sample ID:

    LCS Sample Inj Date:

    LCSD Lab File ID: GC20B-1314-62

    LCSD LRF ID: LCSD-72

    07/14/2012 23:48:39

    AP17981SLCSD Lab Sample ID:

    LCSD Sample Inj Date:

    COMPOUND

    SPIKEADDED

    LCSCONCENTRATION

    LCSPERCENT

    RECOVERY #

    QC LIMITS

    RECOVERY

    PERCENT(ug) (ug)

    1

    Aroclor 1254 1.00 1.08 108 (70.0-130)

    COMPOUNDSPIKEADDED CONCENTRATION

    LCSD LCSDPERCENT RPD #

    QC LIMITS

    RECRPD(ug) (ug)

    1

    RECOVERY #

    Aroclor 1254 1.00 1.06 106 1.87 20 (70.0-130)

    # Column to be used to flag recovery values

    * Values outside of QC limits

    Spike Recovery: out of outside limits.0 2

    QC Limits based upon laboratory defaults.1

    RPD: out of outside limits.0 1

    COMMENTS:

  • PCB METHOD BLANK SUMMARY

    Laboratory Name:

    ELAP ID No:

    Method Blank ID:

    Blank Sample ID:

    SDG No:

    Date Analyzed:

    Time Analyzed:

    Instrument ID: Lab File ID:

    THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:

    CLIENT

    SAMPLE ID

    LAB

    SAMPLE ID

    LAB

    FILE ID

    DATE / TIME

    ANALYZED

    PBLK-88

    GC Column (1):

    Pace Analytical Services, Inc.

    11078

    12060435

    GC10F-415-38

    AP13253B

    06/26/2012

    06:29:25

    Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    GC10F

    4C-1

    Date Extracted: 06/23/2012

    Matrix: Solvent

    Extraction Type: Soxhlet Method (3540C)

    062312-0 AP13253 GC10F-415-39 06/26/2012 06:42:01

    062312-1 AP13254 GC10F-415-41 06/26/2012 07:07:14

    062312-2 AP13255 GC10F-415-42 06/26/2012 07:19:50

    FORM IV-CLP-PCB(PACE)

    Lims Version : 5.0.6.6Print date: 7/17/2012

  • PCB METHOD BLANK SUMMARY

    Laboratory Name:

    ELAP ID No:

    Method Blank ID:

    Blank Sample ID:

    SDG No:

    Date Analyzed:

    Time Analyzed:

    Instrument ID: Lab File ID:

    THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:

    CLIENT

    SAMPLE ID

    LAB

    SAMPLE ID

    LAB

    FILE ID

    DATE / TIME

    ANALYZED

    PBLK-88

    GC Column (1):

    Pace Analytical Services, Inc.

    11078

    12060435

    GC10B-388-38

    AP13253B

    06/26/2012

    06:29:29

    Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm

    GC10B

    4C-1

    Date Extracted: 06/23/2012

    Matrix: Solvent

    Extraction Type: Soxhlet Method (3540C)

    062312-0 AP13253 GC10B-388-39 06/26/2012 06:42:05

    062312-1 AP13254 GC10B-388-41 06/26/2012 07:07:18

    062312-2 AP13255 GC10B-388-42 06/26/2012 07:19:54

    FORM IV-CLP-PCB(PACE)

    Lims Version : 5.0.6.6Print date: 7/17/2012

  • PCB METHOD BLANK SUMMARY

    Laboratory Name:

    ELAP ID No:

    Method Blank ID:

    Blank Sample ID:

    SDG No:

    Date Analyzed:

    Time Analyzed:

    Instrument ID: Lab File ID:

    THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:

    CLIENT

    SAMPLE ID

    LAB

    SAMPLE ID

    LAB

    FILE ID

    DATE / TIME

    ANALYZED

    PBLK-66

    GC Column (1):

    Pace Analytical Services, Inc.

    11078

    12060396

    GC10F-415-33

    AP12679B

    06/26/2012

    05:26:24

    Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    GC10F

    4C-1

    Date Extracted: 06/22/2012

    Matrix: Solvent

    Extraction Type: Soxhlet Method (3540C)

    VER PUF LOT# 062112-0 AP12679 GC10F-415-34 06/26/2012 05:39:01

    VER PUF LOT# 062112-1 AP12680 GC10F-415-35 06/26/2012 05:51:37

    VER PUF LOT# 062112-2 AP12681 GC10F-415-36 06/26/2012 06:04:13

    VER PUF LOT# 062112-4 AP12682 GC10F-415-37 06/26/2012 06:16:49

    FORM IV-CLP-PCB(PACE)

    Lims Version : 5.0.6.6Print date: 7/17/2012

  • PCB METHOD BLANK SUMMARY

    Laboratory Name:

    ELAP ID No:

    Method Blank ID:

    Blank Sample ID:

    SDG No:

    Date Analyzed:

    Time Analyzed:

    Instrument ID: Lab File ID:

    THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:

    CLIENT

    SAMPLE ID

    LAB

    SAMPLE ID

    LAB

    FILE ID

    DATE / TIME

    ANALYZED

    PBLK-66

    GC Column (1):

    Pace Analytical Services, Inc.

    11078

    12060396

    GC10B-388-33

    AP12679B

    06/26/2012

    05:26:28

    Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm

    GC10B

    4C-1

    Date Extracted: 06/22/2012

    Matrix: Solvent

    Extraction Type: Soxhlet Method (3540C)

    VER PUF LOT# 062112-0 AP12679 GC10B-388-34 06/26/2012 05:39:05

    VER PUF LOT# 062112-1 AP12680 GC10B-388-35 06/26/2012 05:51:41

    VER PUF LOT# 062112-2 AP12681 GC10B-388-36 06/26/2012 06:04:17

    VER PUF LOT# 062112-4 AP12682 GC10B-388-37 06/26/2012 06:16:53

    FORM IV-CLP-PCB(PACE)

    Lims Version : 5.0.6.6Print date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP13253

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    VER PUF LOT# 062312-0

    11078

    12060435

    Polyurethane Foam

    N/A

    GC10F-415-39

    06/23/2012

    06/23/2012

    06/26/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    Client ID:

    LRF ID: 12060435-01

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC10B-388-39

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:Blank ID: AP13253BU - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP13254

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    VER PUF LOT# 062312-1

    11078

    12060435

    Polyurethane Foam

    N/A

    GC10F-415-41

    06/23/2012

    06/23/2012

    06/26/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    Client ID:

    LRF ID: 12060435-02

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC10B-388-41

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:Blank ID: AP13253BU - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP12682

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    VER PUF LOT# 062112-4

    11078

    12060396

    Filter

    N/A

    GC10F-415-37

    06/21/2012

    06/22/2012

    06/26/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    Client ID:

    LRF ID: 12060396-04

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC10B-388-37

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:Blank ID: AP12679BU - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17981

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    BLK-071312-100

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-63

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-01

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-63

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:Note: There were few non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17982

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    SL-4-071312-003

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-64

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-02

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-64

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.821 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 2.71 PE111097-69-1 Aroclor 1254 1.77 AF111096-82-5 Aroclor 1260 0.335 AG1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17983

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    SL-4CO-071312-005

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-65

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-03

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-65

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 1.01 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 2.75 PE111097-69-1 Aroclor 1254 1.70 AF111096-82-5 Aroclor 1260 0.304 AG1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17984RR1

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    SL-5-071312-302

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1329-4

    07/13/2012

    07/13/2012

    07/18/20123

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-04RR1

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1318-4

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.300 U111104-28-2 Aroclor 1221 0.891 PB111141-16-5 Aroclor 1232 0.300 U153469-21-9 Aroclor 1242 0.300 U112672-29-6 Aroclor 1248 7.64 PE111097-69-1 Aroclor 1254 4.12 AF111096-82-5 Aroclor 1260 0.558 AG1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17985

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    SL-7-071312-012

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-67

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-05

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-67

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.384 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 1.61 PE111097-69-1 Aroclor 1254 1.04 AF111096-82-5 Aroclor 1260 0.212 AG1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17986

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    SL-11-071312-004

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-68

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-06

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-68

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.398 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.701 PE111097-69-1 Aroclor 1254 0.432 AF111096-82-5 Aroclor 1260 0.144 AG1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17987

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    SL-13-071312-002

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-70

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-07

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-70

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.836 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 1.06 PE111097-69-1 Aroclor 1254 0.626 AF111096-82-5 Aroclor 1260 0.228 AG1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17988

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    SL-15-071312-010

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-71

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-08

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-71

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.421 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.792 PE111097-69-1 Aroclor 1254 0.652 AF111096-82-5 Aroclor 1260 0.240 AG1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17989

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    SL-16-071312-009

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-72

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-09

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-72

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.466 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.741 PE111097-69-1 Aroclor 1254 0.593 AF111096-82-5 Aroclor 1260 0.123 AG1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17990

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    SL-17-071312-006

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-73

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-10

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-73

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.699 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.625 PE111097-69-1 Aroclor 1254 0.414 AF111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17991

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    BK-5-071312-008

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-74

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-11

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-74

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.458 PB,P111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.350 PE,P111097-69-1 Aroclor 1254 0.708 AF111096-82-5 Aroclor 1260 0.115 AG1

    Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.P - Indicates percent difference (PD) between primary and secondary GC column analysis exceeds 40%.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17992

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    FS-071312-062312-2

    11078

    12070263

    Polyurethane Foam

    N/A

    GC20F-1325-75

    07/13/2012

    07/13/2012

    07/15/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: 12070263-12

    Column 1 Information:

    Injection Volume:

    Lab File ID: GC20B-1314-75

    1.0 uL

    GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 1.04111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:Note: There were few non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP13253B

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    METHOD BLANK

    11078

    12060435

    Solvent

    N/AGC10B-388-38

    06/23/2012

    06/26/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm

    Client ID:

    LRF ID: PBLK-88

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 0.100 U

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP13253B

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    METHOD BLANK

    11078

    12060435

    Solvent

    N/AGC10F-415-38

    06/23/2012

    06/26/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    Client ID:

    LRF ID: PBLK-88

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 0.100 U

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP12679B

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    METHOD BLANK

    11078

    12060396

    Solvent

    N/AGC10B-388-33

    06/22/2012

    06/26/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm

    Client ID:

    LRF ID: PBLK-66

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 0.100 U

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP12679B

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    METHOD BLANK

    11078

    12060396

    Solvent

    N/AGC10F-415-33

    06/22/2012

    06/26/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm

    Client ID:

    LRF ID: PBLK-66

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 0.100 U

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/17/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17981B

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    METHOD BLANK

    11078

    12070263

    Polyurethane Foam

    N/AGC20F-1325-60

    07/13/2012

    07/14/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: PBLK-72

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 0.100 U

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17981B

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    METHOD BLANK

    11078

    12070263

    Polyurethane Foam

    N/AGC20B-1314-60

    07/13/2012

    07/14/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: PBLK-72

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 0.100 U

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17981L

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    LAB CONTROL SPIKE

    11078

    12070263

    Polyurethane Foam

    N/AGC20F-1325-61

    07/13/2012

    07/14/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: LCS-72

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 1.06

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17981L

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    LAB CONTROL SPIKE

    11078

    12070263

    Polyurethane Foam

    N/AGC20B-1314-61

    07/13/2012

    07/14/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: LCS-72

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 1.08

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17981S

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    LAB CONTROL SPIKE DUPLICATE

    11078

    12070263

    Polyurethane Foam

    N/AGC20F-1325-62

    07/13/2012

    07/14/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: LCSD-72

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 1.07

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Pace Analytical Services, Inc.

    1D-1

    AP17981S

    Laboratory Name:

    ELAP ID No:

    Matrix:

    Sample wt(Dry)/vol:

    Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:

    Date Extracted:

    Date Analyzed:

    Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:

    Sulfur Cleanup:

    Extraction:

    LAB CONTROL SPIKE DUPLICATE

    11078

    12070263

    Polyurethane Foam

    N/AGC20B-1314-62

    07/13/2012

    07/14/20121

    N/A

    Soxhlet Method (3540C)

    5000 uL

    1.0 uLEPA Method TO-4A

    YES

    UG

    GC Column:Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:

    LRF ID: LCSD-72

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U

    11104-28-2 Aroclor 1221 0.100 U

    11141-16-5 Aroclor 1232 0.100 U

    53469-21-9 Aroclor 1242 0.100 U

    12672-29-6 Aroclor 1248 0.100 U

    11097-69-1 Aroclor 1254 1.06

    11096-82-5 Aroclor 1260 0.100 U

    Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 7/19/2012

  • Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm

    SURR 1 (Col 1)

    LRF ID

    SURR 1

    Laboratory Name:Pace Analytical Services, Inc. SDG: 12070585

    GC Column (1):

    GC Column (2):

    TOTAL

    % REC # OUT

    2F-1PCB SURROGATE RECOVERY

    FILE ID

    ELAP ID No: 11078

    LABSAMPLE ID

    (Col 1)SURR 2

    % REC #

    SURR 2 (Col 2) (Col 2)

    % REC # % REC #

    LAB OTHER(1)

    OTHER(2)

    PBLK-22 77.9 89.9 0GC20F-1341-15AP21637B

    PBLK-22 81.9 93.0 0GC20B-1330-15AP21637B

    12070585-01 78.1 84.3 0GC20F-1341-16AP21637

    12070585-01 76.7 88.3 0GC20B-1330-16AP21637

    12070585-02 76.2 91.2 0GC20F-1341-17AP21638

    12070585-02 81.5 94.4 0GC20B-1330-17AP21638

    12070585-03 77.3 93.6 0GC20F-1341-18AP21639

    12070585-03 81.8 97.8 0GC20B-1330-18AP21639

    Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6

    Advisory QC Limits.

    # Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out

    SURR1 = TETRACHLORO-META-XYLENESURR2 = DECACHLOROBIPHENYL (60.0-120)

    (60.0-120)

    Print Date: 8/20/2012Page 3 of 33

  • Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm

    SURR 1 (Col 1)

    LRF ID

    SURR 1

    Laboratory Name:Pace Analytical Services, Inc. SDG: 12080295

    GC Column (1):

    GC Column (2):

    TOTAL

    % REC # OUT

    2F-1PCB SURROGATE RECOVERY

    FILE ID

    ELAP ID No: 11078

    LABSAMPLE ID

    (Col 1)SURR 2

    % REC #

    SURR 2 (Col 2) (Col 2)

    % REC # % REC #

    LAB OTHER(1)

    OTHER(2)

    PBLK-85 81.5 97.2 0GC20F-1356-11AP24448B

    PBLK-85 88.7 95.7 0GC20B-1345-11AP24448B

    LCS-85 90.5 99.3 0GC20F-1356-12AP24448L

    LCS-85 91.8 97.3 0GC20B-1345-12AP24448L

    LCSD-85 85.0 99.3 0GC20F-1356-13AP24448S

    LCSD-85 87.1 95.8 0GC20B-1345-13AP24448S

    12080295-01 86.5 98.1 0GC20F-1356-14AP24448

    12080295-01 87.5 98.6 0GC20B-1345-14AP24448

    12080295-02 106 97.2 0GC20F-1356-15AP24449

    12080295-02 77.4 98.6 0GC20B-1345-15AP24449

    12080295-03 108 101 0GC20F-1356-16AP24450

    12080295-03 84.4 99.4 0GC20B-1345-16AP24450

    12080295-04 112 101 0GC20F-1356-17AP24451

    12080295-04 81.0 97.5 0GC20B-1345-17AP24451

    12080295-05 114 96.8 0GC20F-1356-18AP24452

    12080295-05 73.7 97.6 0GC20B-1345-18AP24452

    12080295-06 107 102 0GC20F-1356-20AP24453

    12080295-06 89.3 96.7 0GC20B-1345-20AP24453

    12080295-07 114 102 0GC20F-1356-21AP24454

    12080295-07 77.1 97.9 0GC20B-1345-21AP24454

    12080295-08 110 101 0GC20F-1356-22AP24455

    12080295-08 86.5 97.1 0GC20B-1345-22AP24455

    12080295-09 116 97.8 0GC20F-1356-23AP24456

    12080295-09 82.9 97.7 0GC20B-1345-23AP24456

    12080295-10 82.4 95.0 0GC20F-1356-24AP24457

    12080295-10 87.5 96.2 0GC20B-1345-24AP24457

    Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6

    Advisory QC Limits.

    # Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out

    SURR1 = TETRACHLORO-META-XYLENESURR2 = DECACHLOROBIPHENYL (60.0-120)

    (60.0-120)

    Print Date: 8/20/2012Page 4 of 33

  • Laboratory Name:

    Method Blank File ID:

    ELAP ID No: SDG No:

    Pace Analytical Services, Inc.

    11078 12080295

    GC20F-1356-11LCS File ID: GC20F-1356-12

    3F-2 LABORATORY CONTROL SPIKE (LCS) RECOVERY

    LCS Lab ID: LCS-85 Blank Sample ID: PBLK-85

    08/16/2012 14:37:20

    AP24448LLCS ID:

    LCS Inj Date:

    Method Blank ID: AP24448B

    Method Blank Inj Date: 08/16/2012 14:24:45

    Polyurethane FoamLCS Matrix: Polyurethane FoamMethod Blank Matrix:

    COMPOUNDSPIKEADDED

    LCSCONCENTRATION

    LCSPERCENT

    RECOVERY #

    QC LIMITS

    RECOVERYPERCENT

    (ug) (ug)

    1

    Aroclor 1254 1.00 1.08 108 70.0-130

    # Column to be used to flag recovery values* Values outside of QC limits

    Spike Recovery: out of outside limits.0 1QC Limits based upon laboratory defaults.1

    COMMENTS:

    Form III-CLP-PCB (PACE) Lims Version : 5.0.6.6Page 5 of 33

  • Laboratory Name:

    Method Blank File ID:

    ELAP ID No: SDG No:

    Pace Analytical Services, Inc.

    11078 12080295

    GC20B-1345-11LCS File ID: GC20B-1345-12

    3F-2 LABORATORY CONTROL SPIKE (LCS) RECOVERY

    LCS Lab ID: LCS-85 Blank Sample ID: PBLK-85

    08/16/2012 14:37:25

    AP24448LLCS ID:

    LCS Inj Date:

    Method Blank ID: AP24448B

    Method Blank Inj Date: 08/16/2012 14:24:50

    Polyurethane FoamLCS Matrix: Polyurethane FoamMethod Blank Matrix:

    COMPOUNDSPIKEADDED

    LCSCONCENTRATION

    LCSPERCENT

    RECOVERY #

    QC LIMITS

    RECOVERYPERCENT

    (ug) (ug)

    1

    Aroclor 1254 1.00 1.06 106 70.0-130

    # Column to be used to flag recovery values* Values outside of QC limits

    Spike Recovery: out of outside limits.0 1QC Limits based upon laboratory defaults.1

    COMMENTS:

    Form III-CLP-PCB (PACE) Lims Version : 5.0.6.6Page 6 of 33

  • Laboratory Name:

    ELAP ID No: SDG No:

    Pace Analytical Services, Inc.

    11078 12080295

    LCS Lab File ID: GC20F-1356-12

    3F-1 PCB LAB CONTROL SAMPLE (LCS) / LAB CONTROL SAMPLE DUPLICATE (LCSD) RECOVERY

    LCS LRF ID: LCS-85

    08/16/2012 14:37:20

    AP24448LLCS Lab Sample ID:

    LCS Sample Inj Date:

    LCSD Lab File ID: GC20F-1356-13

    LCSD LRF ID: LCSD-85

    08/16/2012 14:49:54

    AP24448SLCSD Lab Sample ID:

    LCSD Sample Inj Date:

    COMPOUNDSPIKEADDED

    LCSCONCENTRATION

    LCSPERCENT

    RECOVERY #

    QC LIMITS

    RECOVERYPERCENT

    (ug) (ug)

    1

    Aroclor 1254 1.00 1.08 108 (70.0-130)

    COMPOUNDSPIKEADDED CONCENTRATION

    LCSD LCSDPERCENT RPD #

    QC LIMITSRECRPD(ug) (ug)

    1

    RECOVERY #

    Aroclor 1254 1.00 1.10 110 1.83 20 (70.0-130)

    # Column to be used to flag recovery values* Values outside of QC limits

    Spike Recovery: out of outside limits.0 2

    QC Limits based upon laboratory defaults.1

    RPD: out of outside limits.0 1

    COMMENTS:

    Page 7 of 33

  • Laboratory Name:

    ELAP ID No: SDG No:

    Pace Analytical Services, Inc.

    11078 12080295

    LCS Lab File ID: GC20B-1345-12

    3F-1 PCB LAB CONTROL SAMPLE (LCS) / LAB CONTROL SAMPLE DUPLICATE (LCSD) RECOVERY

    LCS LRF ID: LCS-85

    08/16/2012 14:37:25

    AP24448LLCS Lab Sample ID:

    LCS Sample Inj Date:

    LCSD Lab File ID: GC20B-1345-13

    LCSD LRF ID: LCSD-85

    08/16/2012 14:49:59

    AP24448SLCSD Lab Sample ID:

    LCSD Sample Inj Date:

    COMPOUNDSPIKEADDED

    LCSCONCENTRATION

    LCSPERCENT

    RECOVERY #

    QC LIMITS

    RECOVERYPERCENT

    (ug) (ug)

    1

    Aroclor 1254 1.00 1.06 106 (70.0-130)

    COMPOUNDSPIKEADDED CONCENTRATION

    LCSD LCSDPERCENT RPD #

    QC LIMITSRECRPD(ug) (ug)

    1

    RECOVERY #

    Aroclor 1254 1.00 1.13 113 6.39 20 (70.0-130)

    # Column to be used to flag recovery values* Values outside of QC limits

    Spike Recovery: out of outside limits.0 2

    QC Limits based upon laboratory defaults.1

    RPD: out of outside limits.0 1

    COMMENTS:

    Page 8 of 33

  • PCB METHOD BLANK SUMMARY

    Laboratory Name:

    ELAP ID No:

    Method Blank ID:

    Blank Sample ID:

    SDG No:

    Date Analyzed:

    Time Analyzed:

    Instrument ID: Lab File ID:

    THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:

    CLIENT

    SAMPLE ID

    LAB

    SAMPLE ID

    LAB

    FILE ID

    DATE / TIME

    ANALYZED

    PBLK-22

    GC Column (1):

    Pace Analytical Services, Inc.

    11078

    12070585

    GC20F-1341-15

    AP21637B

    07/30/2012

    15:43:45

    Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    GC20F

    4C-1

    Date Extracted: 07/29/2012

    Matrix: Solvent

    Extraction Type: Soxhlet Method (3540C)

    VER PUF LOT #072812-2 AP21637 GC20F-1341-16 07/30/2012 15:56:18 VER PUF LOT #072812-3 AP21638 GC20F-1341-17 07/30/2012 16:08:53 VER FILTER LOT #072812-4 AP21639 GC20F-1341-18 07/30/2012 16:21:29

    FORM IV-CLP-PCB(PACE)

    Lims Version : 5.0.6.6Print date: 8/20/2012Page 9 of 33

  • PCB METHOD BLANK SUMMARY

    Laboratory Name:

    ELAP ID No:

    Method Blank ID:

    Blank Sample ID:

    SDG No:

    Date Analyzed:

    Time Analyzed:

    Instrument ID: Lab File ID:

    THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:

    CLIENT

    SAMPLE ID

    LAB

    SAMPLE ID

    LAB

    FILE ID

    DATE / TIME

    ANALYZED

    PBLK-22

    GC Column (1):

    Pace Analytical Services, Inc.

    11078

    12070585

    GC20B-1330-15

    AP21637B

    07/30/2012

    15:43:48

    Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm

    GC20B

    4C-1

    Date Extracted: 07/29/2012

    Matrix: Solvent

    Extraction Type: Soxhlet Method (3540C)

    VER PUF LOT #072812-2 AP21637 GC20B-1330-16 07/30/2012 15:56:22 VER PUF LOT #072812-3 AP21638 GC20B-1330-17 07/30/2012 16:08:57 VER FILTER LOT #072812-4 AP21639 GC20B-1330-18 07/30/2012 16:21:33

    FORM IV-CLP-PCB(PACE)

    Lims Version : 5.0.6.6Print date: 8/20/2012Page 10 of 33

  • PCB METHOD BLANK SUMMARY

    Laboratory Name:

    ELAP ID No:

    Method Blank ID:

    Blank Sample ID:

    SDG No:

    Date Analyzed:

    Time Analyzed:

    Instrument ID: Lab File ID:

    THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:

    CLIENT

    SAMPLE ID

    LAB

    SAMPLE ID

    LAB

    FILE ID

    DATE / TIME

    ANALYZED

    PBLK-85

    GC Column (1):

    Pace Analytical Services, Inc.

    11078

    12080295

    GC20F-1356-11

    AP24448B

    08/16/2012

    14:24:45

    Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    GC20F

    4C-1

    Date Extracted: 08/15/2012

    Matrix: Polyurethane Foam (PF4)

    Extraction Type: Soxhlet Method (3540C)

    LCS-85(LAB CONTROL SPIKE) AP24448L GC20F-1356-12 08/16/2012 14:37:20 LCSD-85(LAB CONTROL SPIKE DUPLICATE) AP24448S GC20F-1356-13 08/16/2012 14:49:54 BLK-081512-100 AP24448 GC20F-1356-14 08/16/2012 15:02:30 SL-1-081512-010 AP24449 GC20F-1356-15 08/16/2012 15:15:05 SL-4-081512-003 AP24450 GC20F-1356-16 08/16/2012 15:27:39 SL-4CO-081512-006 AP24451 GC20F-1356-17 08/16/2012 15:40:15 SL-5-081512-002 AP24452 GC20F-1356-18 08/16/2012 15:52:50 SL-14-081512-005 AP24453 GC20F-1356-20 08/16/2012 16:18:00 SL-16-081512-004 AP24454 GC20F-1356-21 08/16/2012 16:30:34 SL-17-081512-009 AP24455 GC20F-1356-22 08/16/2012 16:43:09 BK-5-081512-008 AP24456 GC20F-1356-23 08/16/2012 16:55:44 FS-081512-072812-2 AP24457 GC20F-1356-24 08/16/2012 17:08:18

    FORM IV-CLP-PCB(PACE)

    Lims Version : 5.0.6.6Print date: 8/20/2012Page 11 of 33

  • PCB METHOD BLANK SUMMARY

    Laboratory Name:

    ELAP ID No:

    Method Blank ID:

    Blank Sample ID:

    SDG No:

    Date Analyzed:

    Time Analyzed:

    Instrument ID: Lab File ID:

    THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:

    CLIENT

    SAMPLE ID

    LAB

    SAMPLE ID

    LAB

    FILE ID

    DATE / TIME

    ANALYZED

    PBLK-85

    GC Column (1):

    Pace Analytical Services, Inc.

    11078

    12080295

    GC20B-1345-11

    AP24448B

    08/16/2012

    14:24:50

    Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm

    GC20B

    4C-1

    Date Extracted: 08/15/2012

    Matrix: Polyurethane Foam (PF4)

    Extraction Type: Soxhlet Method (3540C)

    LCS-85(LAB CONTROL SPIKE) AP24448L GC20B-1345-12 08/16/2012 14:37:25 LCSD-85(LAB CONTROL SPIKE DUPLICATE) AP24448S GC20B-1345-13 08/16/2012 14:49:59 BLK-081512-100 AP24448 GC20B-1345-14 08/16/2012 15:02:35 SL-1-081512-010 AP24449 GC20B-1345-15 08/16/2012 15:15:09 SL-4-081512-003 AP24450 GC20B-1345-16 08/16/2012 15:27:44 SL-4CO-081512-006 AP24451 GC20B-1345-17 08/16/2012 15:40:19 SL-5-081512-002 AP24452 GC20B-1345-18 08/16/2012 15:52:55 SL-14-081512-005 AP24453 GC20B-1345-20 08/16/2012 16:18:04 SL-16-081512-004 AP24454 GC20B-1345-21 08/16/2012 16:30:39 SL-17-081512-009 AP24455 GC20B-1345-22 08/16/2012 16:43:13 BK-5-081512-008 AP24456 GC20B-1345-23 08/16/2012 16:55:49 FS-081512-072812-2 AP24457 GC20B-1345-24 08/16/2012 17:08:23

    FORM IV-CLP-PCB(PACE)

    Lims Version : 5.0.6.6Print date: 8/20/2012Page 12 of 33

  • Pace Analytical Services, Inc.

    1D-1

    AP21637

    Laboratory Name:ELAP ID No:Matrix:Sample wt(Dry)/vol:Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:Date Extracted:Date Analyzed:Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:Sulfur Cleanup:

    Extraction:

    VER PUF LOT #072812-211078

    12070585

    Polyurethane FoamN/A

    GC20F-1341-16

    07/29/201207/29/201207/30/2012

    1

    N/ASoxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:LRF ID: 12070585-01

    Column 1 Information:

    Injection Volume:Lab File ID: GC20B-1330-16

    1.0 uLGC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:Blank ID: AP21637BU - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 8/20/2012Page 13 of 33

  • Pace Analytical Services, Inc.

    1D-1

    AP21638

    Laboratory Name:ELAP ID No:Matrix:Sample wt(Dry)/vol:Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:Date Extracted:Date Analyzed:Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:Sulfur Cleanup:

    Extraction:

    VER PUF LOT #072812-311078

    12070585

    Polyurethane FoamN/A

    GC20F-1341-17

    07/29/201207/29/201207/30/2012

    1

    N/ASoxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:LRF ID: 12070585-02

    Column 1 Information:

    Injection Volume:Lab File ID: GC20B-1330-17

    1.0 uLGC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:

    NumberColumn

    PCB ANALYSIS DATA SHEET

    12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1

    Laboratory Qualifiers:Blank ID: AP21637BU - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.

    Media has been certified for use.

    Lims Version : 5.0.6.6

    FORM I-CLP-PCB

    Print Date: 8/20/2012Page 14 of 33

  • Pace Analytical Services, Inc.

    1D-1

    AP21639

    Laboratory Name:ELAP ID No:Matrix:Sample wt(Dry)/vol:Percent Moisture:

    Conc. Extract Volume:

    Injection Volume:

    SDG No:

    Lab Sample ID:

    Lab File ID:

    Date Received:Date Extracted:Date Analyzed:Dilution Factor:

    CAS NO COMPOUND NAMECONCENTRATION

    Q

    Method:Sulfur Cleanup:

    Extraction:

    VER FILTER LOT #072812-411078

    12070585

    FilterN/A

    GC20F-1341-18

    07/29/201207/29/201207/30/2012

    1

    N/ASoxhlet Method (3540C)

    5000 uL

    1.0 uL

    EPA Method TO-4A

    YES

    UG

    GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm

    Client ID:LRF ID: 12070585-03

    Column 1 Information:

    Injection Volume:Lab File ID: GC20B-1330-18

    1.0 uLGC Colu