1D-1 PCB ANALYSIS DATA SHEETConc. Extract Volume: Injection Volume: SDG No: Lab Sample ID: Lab File...
Transcript of 1D-1 PCB ANALYSIS DATA SHEETConc. Extract Volume: Injection Volume: SDG No: Lab Sample ID: Lab File...
-
Pace Analytical Services, Inc.
1D-1
AP17506
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
SL-17-071112-006
11078
12070226
Polyurethane Foam
N/A
GC20F-1324-16
07/12/2012
07/12/2012
07/13/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070226-09
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1313-16
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.547 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.497 PD112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.408 AF111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PD-Aroclor 1242 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1242 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP17507
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
BK-5-071112-008
11078
12070226
Polyurethane Foam
N/A
GC20F-1324-17
07/12/2012
07/12/2012
07/13/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070226-10
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1313-17
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.244 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.541 AF111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP17508
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
FS-071112-062312-2
11078
12070226
Polyurethane Foam
N/A
GC20F-1324-18
07/12/2012
07/12/2012
07/13/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070226-11
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1313-18
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 1.05111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:Note: There were few non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP12679B
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
METHOD BLANK
11078
12060396
Solvent
N/AGC10F-415-33
06/22/2012
06/26/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
Client ID:
LRF ID: PBLK-66
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 0.100 U
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP13253B
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
METHOD BLANK
11078
12060435
Solvent
N/AGC10F-415-38
06/23/2012
06/26/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
Client ID:
LRF ID: PBLK-88
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 0.100 U
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP17498B
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
METHOD BLANK
11078
12070226
Polyurethane Foam
N/AGC20F-1324-4
07/12/2012
07/13/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: PBLK-57
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 0.100 U
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP17498L
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
LAB CONTROL SPIKE
11078
12070226
Polyurethane Foam
N/AGC20F-1324-5
07/12/2012
07/13/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: LCS-57
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 1.06
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP17498S
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
LAB CONTROL SPIKE DUPLICATE
11078
12070226
Polyurethane Foam
N/AGC20F-1324-6
07/12/2012
07/13/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: LCSD-57
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 1.05
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm
SURR 1 (Col 1)
LRF ID
SURR 1
Laboratory Name:Pace Analytical Services, Inc. SDG: 12060435
GC Column (1):
GC Column (2):
TOTAL
% REC # OUT
2F-1PCB SURROGATE RECOVERY
FILE ID
ELAP ID No: 11078
LABSAMPLE ID
(Col 1)SURR 2
% REC #
SURR 2 (Col 2) (Col 2)
% REC # % REC #
LAB OTHER(1)
OTHER(2)
PBLK-88 86.6 95.0 0GC10F-415-38AP13253B
PBLK-88 87.1 95.5 0GC10B-388-38AP13253B
12060435-01 99.7 104 0GC10F-415-39AP13253
12060435-01 98.4 105 0GC10B-388-39AP13253
12060435-02 94.8 102 0GC10F-415-41AP13254
12060435-02 93.9 99.3 0GC10B-388-41AP13254
12060435-03 89.1 101 0GC10F-415-42AP13255
12060435-03 89.8 103 0GC10B-388-42AP13255
Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6
Advisory QC Limits.
# Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out
SURR1 = TETRACHLORO-META-XYLENE
SURR2 = DECACHLOROBIPHENYL (60.0-120)
(60.0-120)
Print Date: 7/17/2012
-
Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm
SURR 1 (Col 1)
LRF ID
SURR 1
Laboratory Name:Pace Analytical Services, Inc. SDG: 12060396
GC Column (1):
GC Column (2):
TOTAL
% REC # OUT
2F-1PCB SURROGATE RECOVERY
FILE ID
ELAP ID No: 11078
LABSAMPLE ID
(Col 1)SURR 2
% REC #
SURR 2 (Col 2) (Col 2)
% REC # % REC #
LAB OTHER(1)
OTHER(2)
PBLK-66 86.8 94.9 0GC10F-415-33AP12679B
PBLK-66 86.0 95.7 0GC10B-388-33AP12679B
12060396-01 90.8 100 0GC10F-415-34AP12679
12060396-01 93.1 100 0GC10B-388-34AP12679
12060396-02 90.8 99.9 0GC10F-415-35AP12680
12060396-02 93.0 100 0GC10B-388-35AP12680
12060396-03 88.2 95.1 0GC10F-415-36AP12681
12060396-03 88.2 95.2 0GC10B-388-36AP12681
12060396-04 88.9 98.5 0GC10F-415-37AP12682
12060396-04 90.1 99.8 0GC10B-388-37AP12682
Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6
Advisory QC Limits.
# Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out
SURR1 = TETRACHLORO-META-XYLENE
SURR2 = DECACHLOROBIPHENYL (60.0-120)
(60.0-120)
Print Date: 7/17/2012
-
Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm
SURR 1 (Col 1)
LRF ID
SURR 1
Laboratory Name:Pace Analytical Services, Inc. SDG: 12070263
GC Column (1):
GC Column (2):
TOTAL
% REC # OUT
2F-1PCB SURROGATE RECOVERY
FILE ID
ELAP ID No: 11078
LABSAMPLE ID
(Col 1)SURR 2
% REC #
SURR 2 (Col 2) (Col 2)
% REC # % REC #
LAB OTHER(1)
OTHER(2)
PBLK-72 83.9 96.9 0GC20F-1325-60AP17981B
PBLK-72 87.6 99.6 0GC20B-1314-60AP17981B
LCS-72 84.3 98.3 0GC20F-1325-61AP17981L
LCS-72 89.9 103 0GC20B-1314-61AP17981L
LCSD-72 82.3 96.3 0GC20F-1325-62AP17981S
LCSD-72 84.9 98.7 0GC20B-1314-62AP17981S
12070263-01 82.9 95.1 0GC20F-1325-63AP17981
12070263-01 87.1 98.7 0GC20B-1314-63AP17981
12070263-02 97.9 97.8 0GC20F-1325-64AP17982
12070263-02 82.5 101 0GC20B-1314-64AP17982
12070263-03 102 91.9 0GC20F-1325-65AP17983
12070263-03 82.2 95.9 0GC20B-1314-65AP17983
12070263-04RR1 71.9 D 46.2 D 0GC20F-1329-4AP17984RR1
12070263-04RR1 70.4 D 73.1 D 0GC20B-1318-4AP17984RR1
12070263-05 111 94.2 0GC20F-1325-67AP17985
12070263-05 83.3 98.4 0GC20B-1314-67AP17985
12070263-06 93.9 90.2 0GC20F-1325-68AP17986
12070263-06 81.1 94.5 0GC20B-1314-68AP17986
12070263-07 104 96.5 0GC20F-1325-70AP17987
12070263-07 85.7 98.8 0GC20B-1314-70AP17987
12070263-08 88.5 90.6 0GC20F-1325-71AP17988
12070263-08 83.7 97.2 0GC20B-1314-71AP17988
12070263-09 109 95.1 0GC20F-1325-72AP17989
12070263-09 85.6 100 0GC20B-1314-72AP17989
12070263-10 90.2 91.3 0GC20F-1325-73AP17990
12070263-10 77.3 94.1 0GC20B-1314-73AP17990
12070263-11 93.6 92.4 0GC20F-1325-74AP17991
12070263-11 79.2 98.2 0GC20B-1314-74AP17991
Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6
Advisory QC Limits.
# Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out
SURR1 = TETRACHLORO-META-XYLENE
SURR2 = DECACHLOROBIPHENYL (60.0-120)
(60.0-120)
Print Date: 7/19/2012
-
Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm
SURR 1 (Col 1)
LRF ID
SURR 1
Laboratory Name:Pace Analytical Services, Inc. SDG: 12070263
GC Column (1):
GC Column (2):
TOTAL
% REC # OUT
2F-1PCB SURROGATE RECOVERY
FILE ID
ELAP ID No: 11078
LABSAMPLE ID
(Col 1)SURR 2
% REC #
SURR 2 (Col 2) (Col 2)
% REC # % REC #
LAB OTHER(1)
OTHER(2)
12070263-12 80.1 94.0 0GC20F-1325-75AP17992
12070263-12 88.0 101 0GC20B-1314-75AP17992
Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6
Advisory QC Limits.
# Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out
SURR1 = TETRACHLORO-META-XYLENE
SURR2 = DECACHLOROBIPHENYL (60.0-120)
(60.0-120)
Print Date: 7/19/2012
-
Laboratory Name:
Method Blank File ID:
ELAP ID No: SDG No:
Pace Analytical Services, Inc.
11078 12070263
GC20F-1325-60LCS File ID: GC20F-1325-61
3F-2 LABORATORY CONTROL SPIKE (LCS) RECOVERY
LCS Lab ID: LCS-72 Blank Sample ID: PBLK-72
07/14/2012 23:36:00
AP17981LLCS ID:
LCS Inj Date:
Method Blank ID: AP17981B
Method Blank Inj Date: 07/14/2012 23:23:26
Polyurethane FoamLCS Matrix: Polyurethane FoamMethod Blank Matrix:
COMPOUNDSPIKEADDED
LCSCONCENTRATION
LCSPERCENT
RECOVERY #
QC LIMITS
RECOVERY
PERCENT(ug) (ug)
1
Aroclor 1254 1.00 1.06 106 70.0-130
# Column to be used to flag recovery values
* Values outside of QC limits
Spike Recovery: out of outside limits.0 1
QC Limits based upon laboratory defaults.1
COMMENTS:
Form III-CLP-PCB (PACE)Lims Version : 5.0.6.6
-
Laboratory Name:
Method Blank File ID:
ELAP ID No: SDG No:
Pace Analytical Services, Inc.
11078 12070263
GC20B-1314-60LCS File ID: GC20B-1314-61
3F-2 LABORATORY CONTROL SPIKE (LCS) RECOVERY
LCS Lab ID: LCS-72 Blank Sample ID: PBLK-72
07/14/2012 23:36:05
AP17981LLCS ID:
LCS Inj Date:
Method Blank ID: AP17981B
Method Blank Inj Date: 07/14/2012 23:23:30
Polyurethane FoamLCS Matrix: Polyurethane FoamMethod Blank Matrix:
COMPOUNDSPIKEADDED
LCSCONCENTRATION
LCSPERCENT
RECOVERY #
QC LIMITS
RECOVERY
PERCENT(ug) (ug)
1
Aroclor 1254 1.00 1.08 108 70.0-130
# Column to be used to flag recovery values
* Values outside of QC limits
Spike Recovery: out of outside limits.0 1
QC Limits based upon laboratory defaults.1
COMMENTS:
Form III-CLP-PCB (PACE)Lims Version : 5.0.6.6
-
Laboratory Name:
ELAP ID No: SDG No:
Pace Analytical Services, Inc.
11078 12070263
LCS Lab File ID: GC20F-1325-61
3F-1 PCB LAB CONTROL SAMPLE (LCS) / LAB CONTROL SAMPLE DUPLICATE (LCSD) RECOVERY
LCS LRF ID: LCS-72
07/14/2012 23:36:00
AP17981LLCS Lab Sample ID:
LCS Sample Inj Date:
LCSD Lab File ID: GC20F-1325-62
LCSD LRF ID: LCSD-72
07/14/2012 23:48:35
AP17981SLCSD Lab Sample ID:
LCSD Sample Inj Date:
COMPOUND
SPIKEADDED
LCSCONCENTRATION
LCSPERCENT
RECOVERY #
QC LIMITS
RECOVERY
PERCENT(ug) (ug)
1
Aroclor 1254 1.00 1.06 106 (70.0-130)
COMPOUNDSPIKEADDED CONCENTRATION
LCSD LCSDPERCENT RPD #
QC LIMITS
RECRPD(ug) (ug)
1
RECOVERY #
Aroclor 1254 1.00 1.07 107 0.939 20 (70.0-130)
# Column to be used to flag recovery values
* Values outside of QC limits
Spike Recovery: out of outside limits.0 2
QC Limits based upon laboratory defaults.1
RPD: out of outside limits.0 1
COMMENTS:
-
Laboratory Name:
ELAP ID No: SDG No:
Pace Analytical Services, Inc.
11078 12070263
LCS Lab File ID: GC20B-1314-61
3F-1 PCB LAB CONTROL SAMPLE (LCS) / LAB CONTROL SAMPLE DUPLICATE (LCSD) RECOVERY
LCS LRF ID: LCS-72
07/14/2012 23:36:05
AP17981LLCS Lab Sample ID:
LCS Sample Inj Date:
LCSD Lab File ID: GC20B-1314-62
LCSD LRF ID: LCSD-72
07/14/2012 23:48:39
AP17981SLCSD Lab Sample ID:
LCSD Sample Inj Date:
COMPOUND
SPIKEADDED
LCSCONCENTRATION
LCSPERCENT
RECOVERY #
QC LIMITS
RECOVERY
PERCENT(ug) (ug)
1
Aroclor 1254 1.00 1.08 108 (70.0-130)
COMPOUNDSPIKEADDED CONCENTRATION
LCSD LCSDPERCENT RPD #
QC LIMITS
RECRPD(ug) (ug)
1
RECOVERY #
Aroclor 1254 1.00 1.06 106 1.87 20 (70.0-130)
# Column to be used to flag recovery values
* Values outside of QC limits
Spike Recovery: out of outside limits.0 2
QC Limits based upon laboratory defaults.1
RPD: out of outside limits.0 1
COMMENTS:
-
PCB METHOD BLANK SUMMARY
Laboratory Name:
ELAP ID No:
Method Blank ID:
Blank Sample ID:
SDG No:
Date Analyzed:
Time Analyzed:
Instrument ID: Lab File ID:
THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:
CLIENT
SAMPLE ID
LAB
SAMPLE ID
LAB
FILE ID
DATE / TIME
ANALYZED
PBLK-88
GC Column (1):
Pace Analytical Services, Inc.
11078
12060435
GC10F-415-38
AP13253B
06/26/2012
06:29:25
Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
GC10F
4C-1
Date Extracted: 06/23/2012
Matrix: Solvent
Extraction Type: Soxhlet Method (3540C)
062312-0 AP13253 GC10F-415-39 06/26/2012 06:42:01
062312-1 AP13254 GC10F-415-41 06/26/2012 07:07:14
062312-2 AP13255 GC10F-415-42 06/26/2012 07:19:50
FORM IV-CLP-PCB(PACE)
Lims Version : 5.0.6.6Print date: 7/17/2012
-
PCB METHOD BLANK SUMMARY
Laboratory Name:
ELAP ID No:
Method Blank ID:
Blank Sample ID:
SDG No:
Date Analyzed:
Time Analyzed:
Instrument ID: Lab File ID:
THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:
CLIENT
SAMPLE ID
LAB
SAMPLE ID
LAB
FILE ID
DATE / TIME
ANALYZED
PBLK-88
GC Column (1):
Pace Analytical Services, Inc.
11078
12060435
GC10B-388-38
AP13253B
06/26/2012
06:29:29
Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm
GC10B
4C-1
Date Extracted: 06/23/2012
Matrix: Solvent
Extraction Type: Soxhlet Method (3540C)
062312-0 AP13253 GC10B-388-39 06/26/2012 06:42:05
062312-1 AP13254 GC10B-388-41 06/26/2012 07:07:18
062312-2 AP13255 GC10B-388-42 06/26/2012 07:19:54
FORM IV-CLP-PCB(PACE)
Lims Version : 5.0.6.6Print date: 7/17/2012
-
PCB METHOD BLANK SUMMARY
Laboratory Name:
ELAP ID No:
Method Blank ID:
Blank Sample ID:
SDG No:
Date Analyzed:
Time Analyzed:
Instrument ID: Lab File ID:
THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:
CLIENT
SAMPLE ID
LAB
SAMPLE ID
LAB
FILE ID
DATE / TIME
ANALYZED
PBLK-66
GC Column (1):
Pace Analytical Services, Inc.
11078
12060396
GC10F-415-33
AP12679B
06/26/2012
05:26:24
Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
GC10F
4C-1
Date Extracted: 06/22/2012
Matrix: Solvent
Extraction Type: Soxhlet Method (3540C)
VER PUF LOT# 062112-0 AP12679 GC10F-415-34 06/26/2012 05:39:01
VER PUF LOT# 062112-1 AP12680 GC10F-415-35 06/26/2012 05:51:37
VER PUF LOT# 062112-2 AP12681 GC10F-415-36 06/26/2012 06:04:13
VER PUF LOT# 062112-4 AP12682 GC10F-415-37 06/26/2012 06:16:49
FORM IV-CLP-PCB(PACE)
Lims Version : 5.0.6.6Print date: 7/17/2012
-
PCB METHOD BLANK SUMMARY
Laboratory Name:
ELAP ID No:
Method Blank ID:
Blank Sample ID:
SDG No:
Date Analyzed:
Time Analyzed:
Instrument ID: Lab File ID:
THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:
CLIENT
SAMPLE ID
LAB
SAMPLE ID
LAB
FILE ID
DATE / TIME
ANALYZED
PBLK-66
GC Column (1):
Pace Analytical Services, Inc.
11078
12060396
GC10B-388-33
AP12679B
06/26/2012
05:26:28
Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm
GC10B
4C-1
Date Extracted: 06/22/2012
Matrix: Solvent
Extraction Type: Soxhlet Method (3540C)
VER PUF LOT# 062112-0 AP12679 GC10B-388-34 06/26/2012 05:39:05
VER PUF LOT# 062112-1 AP12680 GC10B-388-35 06/26/2012 05:51:41
VER PUF LOT# 062112-2 AP12681 GC10B-388-36 06/26/2012 06:04:17
VER PUF LOT# 062112-4 AP12682 GC10B-388-37 06/26/2012 06:16:53
FORM IV-CLP-PCB(PACE)
Lims Version : 5.0.6.6Print date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP13253
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
VER PUF LOT# 062312-0
11078
12060435
Polyurethane Foam
N/A
GC10F-415-39
06/23/2012
06/23/2012
06/26/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
Client ID:
LRF ID: 12060435-01
Column 1 Information:
Injection Volume:
Lab File ID: GC10B-388-39
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:Blank ID: AP13253BU - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP13254
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
VER PUF LOT# 062312-1
11078
12060435
Polyurethane Foam
N/A
GC10F-415-41
06/23/2012
06/23/2012
06/26/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
Client ID:
LRF ID: 12060435-02
Column 1 Information:
Injection Volume:
Lab File ID: GC10B-388-41
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:Blank ID: AP13253BU - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP12682
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
VER PUF LOT# 062112-4
11078
12060396
Filter
N/A
GC10F-415-37
06/21/2012
06/22/2012
06/26/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
Client ID:
LRF ID: 12060396-04
Column 1 Information:
Injection Volume:
Lab File ID: GC10B-388-37
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:Blank ID: AP12679BU - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP17981
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
BLK-071312-100
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-63
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-01
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-63
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:Note: There were few non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17982
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
SL-4-071312-003
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-64
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-02
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-64
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.821 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 2.71 PE111097-69-1 Aroclor 1254 1.77 AF111096-82-5 Aroclor 1260 0.335 AG1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17983
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
SL-4CO-071312-005
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-65
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-03
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-65
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 1.01 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 2.75 PE111097-69-1 Aroclor 1254 1.70 AF111096-82-5 Aroclor 1260 0.304 AG1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17984RR1
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
SL-5-071312-302
11078
12070263
Polyurethane Foam
N/A
GC20F-1329-4
07/13/2012
07/13/2012
07/18/20123
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-04RR1
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1318-4
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.300 U111104-28-2 Aroclor 1221 0.891 PB111141-16-5 Aroclor 1232 0.300 U153469-21-9 Aroclor 1242 0.300 U112672-29-6 Aroclor 1248 7.64 PE111097-69-1 Aroclor 1254 4.12 AF111096-82-5 Aroclor 1260 0.558 AG1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17985
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
SL-7-071312-012
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-67
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-05
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-67
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.384 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 1.61 PE111097-69-1 Aroclor 1254 1.04 AF111096-82-5 Aroclor 1260 0.212 AG1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17986
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
SL-11-071312-004
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-68
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-06
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-68
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.398 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.701 PE111097-69-1 Aroclor 1254 0.432 AF111096-82-5 Aroclor 1260 0.144 AG1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17987
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
SL-13-071312-002
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-70
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-07
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-70
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.836 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 1.06 PE111097-69-1 Aroclor 1254 0.626 AF111096-82-5 Aroclor 1260 0.228 AG1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17988
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
SL-15-071312-010
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-71
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-08
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-71
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.421 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.792 PE111097-69-1 Aroclor 1254 0.652 AF111096-82-5 Aroclor 1260 0.240 AG1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17989
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
SL-16-071312-009
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-72
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-09
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-72
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.466 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.741 PE111097-69-1 Aroclor 1254 0.593 AF111096-82-5 Aroclor 1260 0.123 AG1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17990
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
SL-17-071312-006
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-73
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-10
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-73
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.699 PB111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.625 PE111097-69-1 Aroclor 1254 0.414 AF111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17991
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
BK-5-071312-008
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-74
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-11
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-74
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.458 PB,P111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.350 PE,P111097-69-1 Aroclor 1254 0.708 AF111096-82-5 Aroclor 1260 0.115 AG1
Laboratory Qualifiers:AF-Aroclor 1254 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.AG-Aroclor 1260 is being reported as the best Aroclor match. The sample exhibits an altered PCB pattern.PB-Aroclor 1221 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1221 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.PE-Aroclor 1248 is being used to report an altered PCB pattern exhibited by the sample. Actual Aroclor 1248 is not present in the sample, but is reported to more accuratelyquantify PCB present in sample that has undergone environmental alteration.Note: There were several non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.P - Indicates percent difference (PD) between primary and secondary GC column analysis exceeds 40%.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17992
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
FS-071312-062312-2
11078
12070263
Polyurethane Foam
N/A
GC20F-1325-75
07/13/2012
07/13/2012
07/15/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: 12070263-12
Column 1 Information:
Injection Volume:
Lab File ID: GC20B-1314-75
1.0 uL
GC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 1.04111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:Note: There were few non-target peaks.U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP13253B
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
METHOD BLANK
11078
12060435
Solvent
N/AGC10B-388-38
06/23/2012
06/26/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm
Client ID:
LRF ID: PBLK-88
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 0.100 U
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP13253B
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
METHOD BLANK
11078
12060435
Solvent
N/AGC10F-415-38
06/23/2012
06/26/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
Client ID:
LRF ID: PBLK-88
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 0.100 U
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP12679B
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
METHOD BLANK
11078
12060396
Solvent
N/AGC10B-388-33
06/22/2012
06/26/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-5, 20 m, 0.18 mm ID, 0.18 µm
Client ID:
LRF ID: PBLK-66
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 0.100 U
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP12679B
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
METHOD BLANK
11078
12060396
Solvent
N/AGC10F-415-33
06/22/2012
06/26/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-1MS, 20 m, 0.18 mm ID, 0.18 µm
Client ID:
LRF ID: PBLK-66
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 0.100 U
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/17/2012
-
Pace Analytical Services, Inc.
1D-1
AP17981B
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
METHOD BLANK
11078
12070263
Polyurethane Foam
N/AGC20F-1325-60
07/13/2012
07/14/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: PBLK-72
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 0.100 U
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17981B
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
METHOD BLANK
11078
12070263
Polyurethane Foam
N/AGC20B-1314-60
07/13/2012
07/14/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: PBLK-72
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 0.100 U
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17981L
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
LAB CONTROL SPIKE
11078
12070263
Polyurethane Foam
N/AGC20F-1325-61
07/13/2012
07/14/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: LCS-72
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 1.06
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17981L
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
LAB CONTROL SPIKE
11078
12070263
Polyurethane Foam
N/AGC20B-1314-61
07/13/2012
07/14/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: LCS-72
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 1.08
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17981S
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
LAB CONTROL SPIKE DUPLICATE
11078
12070263
Polyurethane Foam
N/AGC20F-1325-62
07/13/2012
07/14/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: LCSD-72
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 1.07
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Pace Analytical Services, Inc.
1D-1
AP17981S
Laboratory Name:
ELAP ID No:
Matrix:
Sample wt(Dry)/vol:
Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:
Date Extracted:
Date Analyzed:
Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:
Sulfur Cleanup:
Extraction:
LAB CONTROL SPIKE DUPLICATE
11078
12070263
Polyurethane Foam
N/AGC20B-1314-62
07/13/2012
07/14/20121
N/A
Soxhlet Method (3540C)
5000 uL
1.0 uLEPA Method TO-4A
YES
UG
GC Column:Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm
Client ID:
LRF ID: LCSD-72
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U
11104-28-2 Aroclor 1221 0.100 U
11141-16-5 Aroclor 1232 0.100 U
53469-21-9 Aroclor 1242 0.100 U
12672-29-6 Aroclor 1248 0.100 U
11097-69-1 Aroclor 1254 1.06
11096-82-5 Aroclor 1260 0.100 U
Laboratory Qualifiers:U - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 7/19/2012
-
Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm
SURR 1 (Col 1)
LRF ID
SURR 1
Laboratory Name:Pace Analytical Services, Inc. SDG: 12070585
GC Column (1):
GC Column (2):
TOTAL
% REC # OUT
2F-1PCB SURROGATE RECOVERY
FILE ID
ELAP ID No: 11078
LABSAMPLE ID
(Col 1)SURR 2
% REC #
SURR 2 (Col 2) (Col 2)
% REC # % REC #
LAB OTHER(1)
OTHER(2)
PBLK-22 77.9 89.9 0GC20F-1341-15AP21637B
PBLK-22 81.9 93.0 0GC20B-1330-15AP21637B
12070585-01 78.1 84.3 0GC20F-1341-16AP21637
12070585-01 76.7 88.3 0GC20B-1330-16AP21637
12070585-02 76.2 91.2 0GC20F-1341-17AP21638
12070585-02 81.5 94.4 0GC20B-1330-17AP21638
12070585-03 77.3 93.6 0GC20F-1341-18AP21639
12070585-03 81.8 97.8 0GC20B-1330-18AP21639
Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6
Advisory QC Limits.
# Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out
SURR1 = TETRACHLORO-META-XYLENESURR2 = DECACHLOROBIPHENYL (60.0-120)
(60.0-120)
Print Date: 8/20/2012Page 3 of 33
-
Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm
SURR 1 (Col 1)
LRF ID
SURR 1
Laboratory Name:Pace Analytical Services, Inc. SDG: 12080295
GC Column (1):
GC Column (2):
TOTAL
% REC # OUT
2F-1PCB SURROGATE RECOVERY
FILE ID
ELAP ID No: 11078
LABSAMPLE ID
(Col 1)SURR 2
% REC #
SURR 2 (Col 2) (Col 2)
% REC # % REC #
LAB OTHER(1)
OTHER(2)
PBLK-85 81.5 97.2 0GC20F-1356-11AP24448B
PBLK-85 88.7 95.7 0GC20B-1345-11AP24448B
LCS-85 90.5 99.3 0GC20F-1356-12AP24448L
LCS-85 91.8 97.3 0GC20B-1345-12AP24448L
LCSD-85 85.0 99.3 0GC20F-1356-13AP24448S
LCSD-85 87.1 95.8 0GC20B-1345-13AP24448S
12080295-01 86.5 98.1 0GC20F-1356-14AP24448
12080295-01 87.5 98.6 0GC20B-1345-14AP24448
12080295-02 106 97.2 0GC20F-1356-15AP24449
12080295-02 77.4 98.6 0GC20B-1345-15AP24449
12080295-03 108 101 0GC20F-1356-16AP24450
12080295-03 84.4 99.4 0GC20B-1345-16AP24450
12080295-04 112 101 0GC20F-1356-17AP24451
12080295-04 81.0 97.5 0GC20B-1345-17AP24451
12080295-05 114 96.8 0GC20F-1356-18AP24452
12080295-05 73.7 97.6 0GC20B-1345-18AP24452
12080295-06 107 102 0GC20F-1356-20AP24453
12080295-06 89.3 96.7 0GC20B-1345-20AP24453
12080295-07 114 102 0GC20F-1356-21AP24454
12080295-07 77.1 97.9 0GC20B-1345-21AP24454
12080295-08 110 101 0GC20F-1356-22AP24455
12080295-08 86.5 97.1 0GC20B-1345-22AP24455
12080295-09 116 97.8 0GC20F-1356-23AP24456
12080295-09 82.9 97.7 0GC20B-1345-23AP24456
12080295-10 82.4 95.0 0GC20F-1356-24AP24457
12080295-10 87.5 96.2 0GC20B-1345-24AP24457
Form II-CLP-PCB(PACE)Lims Version : 5.0.6.6
Advisory QC Limits.
# Column to be used to flag recovery values* Values outside of QC limitsD Surrogate diluted out
SURR1 = TETRACHLORO-META-XYLENESURR2 = DECACHLOROBIPHENYL (60.0-120)
(60.0-120)
Print Date: 8/20/2012Page 4 of 33
-
Laboratory Name:
Method Blank File ID:
ELAP ID No: SDG No:
Pace Analytical Services, Inc.
11078 12080295
GC20F-1356-11LCS File ID: GC20F-1356-12
3F-2 LABORATORY CONTROL SPIKE (LCS) RECOVERY
LCS Lab ID: LCS-85 Blank Sample ID: PBLK-85
08/16/2012 14:37:20
AP24448LLCS ID:
LCS Inj Date:
Method Blank ID: AP24448B
Method Blank Inj Date: 08/16/2012 14:24:45
Polyurethane FoamLCS Matrix: Polyurethane FoamMethod Blank Matrix:
COMPOUNDSPIKEADDED
LCSCONCENTRATION
LCSPERCENT
RECOVERY #
QC LIMITS
RECOVERYPERCENT
(ug) (ug)
1
Aroclor 1254 1.00 1.08 108 70.0-130
# Column to be used to flag recovery values* Values outside of QC limits
Spike Recovery: out of outside limits.0 1QC Limits based upon laboratory defaults.1
COMMENTS:
Form III-CLP-PCB (PACE) Lims Version : 5.0.6.6Page 5 of 33
-
Laboratory Name:
Method Blank File ID:
ELAP ID No: SDG No:
Pace Analytical Services, Inc.
11078 12080295
GC20B-1345-11LCS File ID: GC20B-1345-12
3F-2 LABORATORY CONTROL SPIKE (LCS) RECOVERY
LCS Lab ID: LCS-85 Blank Sample ID: PBLK-85
08/16/2012 14:37:25
AP24448LLCS ID:
LCS Inj Date:
Method Blank ID: AP24448B
Method Blank Inj Date: 08/16/2012 14:24:50
Polyurethane FoamLCS Matrix: Polyurethane FoamMethod Blank Matrix:
COMPOUNDSPIKEADDED
LCSCONCENTRATION
LCSPERCENT
RECOVERY #
QC LIMITS
RECOVERYPERCENT
(ug) (ug)
1
Aroclor 1254 1.00 1.06 106 70.0-130
# Column to be used to flag recovery values* Values outside of QC limits
Spike Recovery: out of outside limits.0 1QC Limits based upon laboratory defaults.1
COMMENTS:
Form III-CLP-PCB (PACE) Lims Version : 5.0.6.6Page 6 of 33
-
Laboratory Name:
ELAP ID No: SDG No:
Pace Analytical Services, Inc.
11078 12080295
LCS Lab File ID: GC20F-1356-12
3F-1 PCB LAB CONTROL SAMPLE (LCS) / LAB CONTROL SAMPLE DUPLICATE (LCSD) RECOVERY
LCS LRF ID: LCS-85
08/16/2012 14:37:20
AP24448LLCS Lab Sample ID:
LCS Sample Inj Date:
LCSD Lab File ID: GC20F-1356-13
LCSD LRF ID: LCSD-85
08/16/2012 14:49:54
AP24448SLCSD Lab Sample ID:
LCSD Sample Inj Date:
COMPOUNDSPIKEADDED
LCSCONCENTRATION
LCSPERCENT
RECOVERY #
QC LIMITS
RECOVERYPERCENT
(ug) (ug)
1
Aroclor 1254 1.00 1.08 108 (70.0-130)
COMPOUNDSPIKEADDED CONCENTRATION
LCSD LCSDPERCENT RPD #
QC LIMITSRECRPD(ug) (ug)
1
RECOVERY #
Aroclor 1254 1.00 1.10 110 1.83 20 (70.0-130)
# Column to be used to flag recovery values* Values outside of QC limits
Spike Recovery: out of outside limits.0 2
QC Limits based upon laboratory defaults.1
RPD: out of outside limits.0 1
COMMENTS:
Page 7 of 33
-
Laboratory Name:
ELAP ID No: SDG No:
Pace Analytical Services, Inc.
11078 12080295
LCS Lab File ID: GC20B-1345-12
3F-1 PCB LAB CONTROL SAMPLE (LCS) / LAB CONTROL SAMPLE DUPLICATE (LCSD) RECOVERY
LCS LRF ID: LCS-85
08/16/2012 14:37:25
AP24448LLCS Lab Sample ID:
LCS Sample Inj Date:
LCSD Lab File ID: GC20B-1345-13
LCSD LRF ID: LCSD-85
08/16/2012 14:49:59
AP24448SLCSD Lab Sample ID:
LCSD Sample Inj Date:
COMPOUNDSPIKEADDED
LCSCONCENTRATION
LCSPERCENT
RECOVERY #
QC LIMITS
RECOVERYPERCENT
(ug) (ug)
1
Aroclor 1254 1.00 1.06 106 (70.0-130)
COMPOUNDSPIKEADDED CONCENTRATION
LCSD LCSDPERCENT RPD #
QC LIMITSRECRPD(ug) (ug)
1
RECOVERY #
Aroclor 1254 1.00 1.13 113 6.39 20 (70.0-130)
# Column to be used to flag recovery values* Values outside of QC limits
Spike Recovery: out of outside limits.0 2
QC Limits based upon laboratory defaults.1
RPD: out of outside limits.0 1
COMMENTS:
Page 8 of 33
-
PCB METHOD BLANK SUMMARY
Laboratory Name:
ELAP ID No:
Method Blank ID:
Blank Sample ID:
SDG No:
Date Analyzed:
Time Analyzed:
Instrument ID: Lab File ID:
THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:
CLIENT
SAMPLE ID
LAB
SAMPLE ID
LAB
FILE ID
DATE / TIME
ANALYZED
PBLK-22
GC Column (1):
Pace Analytical Services, Inc.
11078
12070585
GC20F-1341-15
AP21637B
07/30/2012
15:43:45
Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
GC20F
4C-1
Date Extracted: 07/29/2012
Matrix: Solvent
Extraction Type: Soxhlet Method (3540C)
VER PUF LOT #072812-2 AP21637 GC20F-1341-16 07/30/2012 15:56:18 VER PUF LOT #072812-3 AP21638 GC20F-1341-17 07/30/2012 16:08:53 VER FILTER LOT #072812-4 AP21639 GC20F-1341-18 07/30/2012 16:21:29
FORM IV-CLP-PCB(PACE)
Lims Version : 5.0.6.6Print date: 8/20/2012Page 9 of 33
-
PCB METHOD BLANK SUMMARY
Laboratory Name:
ELAP ID No:
Method Blank ID:
Blank Sample ID:
SDG No:
Date Analyzed:
Time Analyzed:
Instrument ID: Lab File ID:
THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:
CLIENT
SAMPLE ID
LAB
SAMPLE ID
LAB
FILE ID
DATE / TIME
ANALYZED
PBLK-22
GC Column (1):
Pace Analytical Services, Inc.
11078
12070585
GC20B-1330-15
AP21637B
07/30/2012
15:43:48
Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm
GC20B
4C-1
Date Extracted: 07/29/2012
Matrix: Solvent
Extraction Type: Soxhlet Method (3540C)
VER PUF LOT #072812-2 AP21637 GC20B-1330-16 07/30/2012 15:56:22 VER PUF LOT #072812-3 AP21638 GC20B-1330-17 07/30/2012 16:08:57 VER FILTER LOT #072812-4 AP21639 GC20B-1330-18 07/30/2012 16:21:33
FORM IV-CLP-PCB(PACE)
Lims Version : 5.0.6.6Print date: 8/20/2012Page 10 of 33
-
PCB METHOD BLANK SUMMARY
Laboratory Name:
ELAP ID No:
Method Blank ID:
Blank Sample ID:
SDG No:
Date Analyzed:
Time Analyzed:
Instrument ID: Lab File ID:
THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:
CLIENT
SAMPLE ID
LAB
SAMPLE ID
LAB
FILE ID
DATE / TIME
ANALYZED
PBLK-85
GC Column (1):
Pace Analytical Services, Inc.
11078
12080295
GC20F-1356-11
AP24448B
08/16/2012
14:24:45
Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
GC20F
4C-1
Date Extracted: 08/15/2012
Matrix: Polyurethane Foam (PF4)
Extraction Type: Soxhlet Method (3540C)
LCS-85(LAB CONTROL SPIKE) AP24448L GC20F-1356-12 08/16/2012 14:37:20 LCSD-85(LAB CONTROL SPIKE DUPLICATE) AP24448S GC20F-1356-13 08/16/2012 14:49:54 BLK-081512-100 AP24448 GC20F-1356-14 08/16/2012 15:02:30 SL-1-081512-010 AP24449 GC20F-1356-15 08/16/2012 15:15:05 SL-4-081512-003 AP24450 GC20F-1356-16 08/16/2012 15:27:39 SL-4CO-081512-006 AP24451 GC20F-1356-17 08/16/2012 15:40:15 SL-5-081512-002 AP24452 GC20F-1356-18 08/16/2012 15:52:50 SL-14-081512-005 AP24453 GC20F-1356-20 08/16/2012 16:18:00 SL-16-081512-004 AP24454 GC20F-1356-21 08/16/2012 16:30:34 SL-17-081512-009 AP24455 GC20F-1356-22 08/16/2012 16:43:09 BK-5-081512-008 AP24456 GC20F-1356-23 08/16/2012 16:55:44 FS-081512-072812-2 AP24457 GC20F-1356-24 08/16/2012 17:08:18
FORM IV-CLP-PCB(PACE)
Lims Version : 5.0.6.6Print date: 8/20/2012Page 11 of 33
-
PCB METHOD BLANK SUMMARY
Laboratory Name:
ELAP ID No:
Method Blank ID:
Blank Sample ID:
SDG No:
Date Analyzed:
Time Analyzed:
Instrument ID: Lab File ID:
THIS METHOD BLANK APPLIES TO THE FOLLOWING SAMPLES AND QC:
CLIENT
SAMPLE ID
LAB
SAMPLE ID
LAB
FILE ID
DATE / TIME
ANALYZED
PBLK-85
GC Column (1):
Pace Analytical Services, Inc.
11078
12080295
GC20B-1345-11
AP24448B
08/16/2012
14:24:50
Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µm
GC20B
4C-1
Date Extracted: 08/15/2012
Matrix: Polyurethane Foam (PF4)
Extraction Type: Soxhlet Method (3540C)
LCS-85(LAB CONTROL SPIKE) AP24448L GC20B-1345-12 08/16/2012 14:37:25 LCSD-85(LAB CONTROL SPIKE DUPLICATE) AP24448S GC20B-1345-13 08/16/2012 14:49:59 BLK-081512-100 AP24448 GC20B-1345-14 08/16/2012 15:02:35 SL-1-081512-010 AP24449 GC20B-1345-15 08/16/2012 15:15:09 SL-4-081512-003 AP24450 GC20B-1345-16 08/16/2012 15:27:44 SL-4CO-081512-006 AP24451 GC20B-1345-17 08/16/2012 15:40:19 SL-5-081512-002 AP24452 GC20B-1345-18 08/16/2012 15:52:55 SL-14-081512-005 AP24453 GC20B-1345-20 08/16/2012 16:18:04 SL-16-081512-004 AP24454 GC20B-1345-21 08/16/2012 16:30:39 SL-17-081512-009 AP24455 GC20B-1345-22 08/16/2012 16:43:13 BK-5-081512-008 AP24456 GC20B-1345-23 08/16/2012 16:55:49 FS-081512-072812-2 AP24457 GC20B-1345-24 08/16/2012 17:08:23
FORM IV-CLP-PCB(PACE)
Lims Version : 5.0.6.6Print date: 8/20/2012Page 12 of 33
-
Pace Analytical Services, Inc.
1D-1
AP21637
Laboratory Name:ELAP ID No:Matrix:Sample wt(Dry)/vol:Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:Date Extracted:Date Analyzed:Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:Sulfur Cleanup:
Extraction:
VER PUF LOT #072812-211078
12070585
Polyurethane FoamN/A
GC20F-1341-16
07/29/201207/29/201207/30/2012
1
N/ASoxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:LRF ID: 12070585-01
Column 1 Information:
Injection Volume:Lab File ID: GC20B-1330-16
1.0 uLGC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:Blank ID: AP21637BU - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 8/20/2012Page 13 of 33
-
Pace Analytical Services, Inc.
1D-1
AP21638
Laboratory Name:ELAP ID No:Matrix:Sample wt(Dry)/vol:Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:Date Extracted:Date Analyzed:Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:Sulfur Cleanup:
Extraction:
VER PUF LOT #072812-311078
12070585
Polyurethane FoamN/A
GC20F-1341-17
07/29/201207/29/201207/30/2012
1
N/ASoxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:LRF ID: 12070585-02
Column 1 Information:
Injection Volume:Lab File ID: GC20B-1330-17
1.0 uLGC Column: Phenomenex, Zebron ZB-5, 30 m, 0.25 mm ID, 0.25 µmColumn 2 Information:
NumberColumn
PCB ANALYSIS DATA SHEET
12674-11-2 Aroclor 1016 0.100 U111104-28-2 Aroclor 1221 0.100 U111141-16-5 Aroclor 1232 0.100 U153469-21-9 Aroclor 1242 0.100 U112672-29-6 Aroclor 1248 0.100 U111097-69-1 Aroclor 1254 0.100 U111096-82-5 Aroclor 1260 0.100 U1
Laboratory Qualifiers:Blank ID: AP21637BU - Denotes analyte not detected at concentration greater than or equal to the Practical Quantitation Limit (PQL). PQLs are adjusted for sample weight/volume and dilutionfactors.
Media has been certified for use.
Lims Version : 5.0.6.6
FORM I-CLP-PCB
Print Date: 8/20/2012Page 14 of 33
-
Pace Analytical Services, Inc.
1D-1
AP21639
Laboratory Name:ELAP ID No:Matrix:Sample wt(Dry)/vol:Percent Moisture:
Conc. Extract Volume:
Injection Volume:
SDG No:
Lab Sample ID:
Lab File ID:
Date Received:Date Extracted:Date Analyzed:Dilution Factor:
CAS NO COMPOUND NAMECONCENTRATION
Q
Method:Sulfur Cleanup:
Extraction:
VER FILTER LOT #072812-411078
12070585
FilterN/A
GC20F-1341-18
07/29/201207/29/201207/30/2012
1
N/ASoxhlet Method (3540C)
5000 uL
1.0 uL
EPA Method TO-4A
YES
UG
GC Column: Phenomenex, Zebron ZB-1, 30 m, 0.25 mm ID, 0.25 µm
Client ID:LRF ID: 12070585-03
Column 1 Information:
Injection Volume:Lab File ID: GC20B-1330-18
1.0 uLGC Colu