1950 -- 1991 1995 2001 2005
MAGNA3 – “built on a proven foundation”
![Page 2: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/2.jpg)
• Grundfos has been selling circulators for 65 years.• There are more than 3 million Alphas and Magnas installed globally.• The warranty rate on Magna in North America has been less than 0.5%
![Page 3: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/3.jpg)
We already have Magna - Why MAGNA3?
![Page 4: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/4.jpg)
MAGNA3 offers the broadest range
14 Models11 Single head3 Twin head
Voltage variants increased115V up to 1HP
208-230V all Liquid Temperature range expanded
14F to 230FCast Iron and Stainless (single head only)
![Page 5: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/5.jpg)
The MAGNA3 saves more energy than any other circulatorHydraulic
Efficiency
10-15%
Electric Efficiency
10-20%
Logic & Control
• CP 30%• PP 55%• AA 65%• FLOWADA
PT ..
Installation & Persistence
Continuous Improvement for Actual System
Needs
![Page 6: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/6.jpg)
Efficiency - “Leave no stone unturned”
Integrated Grundfos Sensor,
Diff. Press & Temperature
Optimized 3D Hydraulic Design
Permanent Magnet Rotor – Stronger
Magnets
Composite Rotor Can – reduced
magnetic losses
Compact Stator – reduces copper and resistance
losses
Insulation Shell reduces heat loss
through pump housing
Intelligent control sizes pump for
demand
Intelligent Monitoring
provides system performance
![Page 7: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/7.jpg)
A Few Comments on Curves
![Page 8: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/8.jpg)
The MAGNA3 offers the most flexibility with
Intelligent Control Modes.• Constant Curve• Constant Differential Pressure• Proportional Differential Pressure• AUTOADAPT• FLOWADAPT• Constant Temperature• Constant Differential Temperature
![Page 9: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/9.jpg)
Electronically “Trim” pump performance
![Page 10: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/10.jpg)
Maintain constant head across the system independent of flow in the system.
Con
stan
t Pre
ssu
re
Con
stan
t C
urv
e
![Page 11: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/11.jpg)
Reduce unneeded pressure as flow decreases.
Pro
port
ion
al
Pre
ssure
Con
stan
t Pre
ssu
re
Con
stan
t C
urv
e
![Page 12: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/12.jpg)
Default setpoint with more aggressive reduction in pressure at low flow
Con
stan
t Pre
ssu
reC
on
stan
t C
urv
e
AU
TO
AD
APT
Pro
port
ion
al Pre
ssu
re
![Page 13: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/13.jpg)
Adapts setpoint to system
Con
stan
t Pre
ssu
reC
on
stan
t C
urv
e
AU
TO
AD
APT
Pro
port
ion
al Pre
ssu
re
![Page 14: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/14.jpg)
AUTOADAPT with user defined flow limit
User Defined Flow LimitationC
on
stan
t Pre
ssu
reC
on
stan
t C
urv
ePro
port
ion
al Pre
ssu
re
FLO
WA
DA
PT
AU
TO
AD
APT
![Page 15: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/15.jpg)
Adapt setpoint to system based on flow limit
Flow Limitation
Con
stan
t Pre
ssu
reC
on
stan
t C
urv
ePro
port
ion
al Pre
ssu
re
FLO
WA
DA
PT
AU
TO
AD
APT
![Page 16: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/16.jpg)
Maintain Constant Temperature in flow pipe
Con
stan
t Pre
ssu
reC
on
stan
t C
urv
ePro
port
ional Pre
ssure
Con
stan
t Te
mpera
ture
![Page 17: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/17.jpg)
Maintain Constant Temperature Delta across load
Con
stan
t Pre
ssu
reC
on
stan
t C
urv
eC
onst
ant
Tem
pera
ture
Diff
ere
nti
al
Tem
pera
ture
![Page 18: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/18.jpg)
MAGNA3 is much more than a pump
• Temperature• Speed
• Flow • Power
• Head• Energy
• BTU• History
![Page 19: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/19.jpg)
MAGNA3 saves $$$ by eliminating the need for additional monitoring equipment and data point integration
Operating ModeSetpointControl ModeAlarm/WarningPower and EnergyPressure HeadFlowSpeed and FrequencyDigital Input/OuputMotor CurrentLiquid TemperatureOperating HoursTotal On TimeNumber of StartsReturn TemperatureBTUBTU/hrDifferential Temperatureand more…..
CIM Accessory delivers all of this data from the pump to the BMS System
• Bacnet• Lonworks• Modbus• Profibus
![Page 20: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/20.jpg)
MAGNA3 saves time with simple Intelligent Interface
![Page 21: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/21.jpg)
Simple from the start – MAGNA3 will guide the user through startup
![Page 22: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/22.jpg)
Simple to navigate menu provides quick access to status or settings
![Page 23: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/23.jpg)
Intelligent monitoring provides the most information ever seen
MAGNA3 comes with a monitoring function, which makes it possible to keep track of the heat energy distribution and consumption within a system. This avoids excessive energy bills caused by system imbalances.
The heat energy meter makes installing a separate energy metering device within your system superfluous.
![Page 24: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/24.jpg)
Historic log enables future system optimization
Every duty point and the operational conditions are tracked and stored in the pump.
The 3D work log and duty over time curve, provide instant overviews of historical pump performance and operational conditions.
The perfect tools for pump optimization, replacement and troubleshooting.
![Page 25: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/25.jpg)
Wire to Water is what’s important
623Hydraulic Efficiency
MAGNA3 40-180
TOTAL Efficiency
EXAMPLE: B&G Stocking Model 623 (1.5x1.5x7) vs MAGNA3 40-180
50%
60%
70%
40%
30%
20%
10%
![Page 26: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/26.jpg)
MAGNA3 is optimized for variable speed efficiency
EXAMPLE: B&G Stocking Model 623 (1.5x1.5x7) vs MAGNA3 40-180
![Page 27: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/27.jpg)
EXAMPLE: B&G Stocking Model 623 (1.5x1.5x7) vs MAGNA3 40-180
![Page 28: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/28.jpg)
“Wire to Water” and EEI ( Energy Efficiency Index) will be how the game is played.
0
10
20
30
40
50
60
70
80
90
100
Typicalinstalledcirculator
EuP 2013 EuP 2015 Benchmark MAGNA3EEI 0.27
EEI 0.23
EEI 0.20
EEI 0.17MAGNA3 65-120
75% Energy Reduction
before AUTOADAPT
![Page 29: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/29.jpg)
Everyone benefits from MAGNA3•Engineers
•Contractors
•Maintenance Managers
•Owners
•You too
![Page 30: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/30.jpg)
MAGNA1 is “Lean and Mean”
Control Settings• 3 Constant Curve• 3 Constant Pressure• 3 Proportional Pressure
Interface• Grundfos Eye• LED Field• Single Button
Communication• None
![Page 31: 1950 --1991199520012005 MAGNA3 – “built on a proven foundation”](https://reader035.fdocuments.in/reader035/viewer/2022062421/56649c765503460f9492a2a4/html5/thumbnails/31.jpg)
A Solution for Every Job
MAGNA3Whisper QuietMaintenance FreeHighest EfficiencyAUTOADAPTFLOWADAPTMonitoringCommunicationand more…
UPSWhisper QuietMaintenance Free3-Speed
MAGNA1Whisper QuietMaintenance FreeHigh Efficiency3-Speed3-Constant Pressure3-Proportional Pressure