13/07/15 TECH DATA SHEET 20157 - Flowtechnology UK · 13/07/15 TECH DATA SHEET 20157. 2 M/1430,...

3
TECH DATA SHEET 20157 13/07/15

Transcript of 13/07/15 TECH DATA SHEET 20157 - Flowtechnology UK · 13/07/15 TECH DATA SHEET 20157. 2 M/1430,...

Page 1: 13/07/15 TECH DATA SHEET 20157 - Flowtechnology UK · 13/07/15 TECH DATA SHEET 20157. 2 M/1430, BM/1430 General Information Model Sub-base Port size Weight Spares kit (kg) M/1430

TECH DATA SHEET 2015713/07/15

Page 2: 13/07/15 TECH DATA SHEET 20157 - Flowtechnology UK · 13/07/15 TECH DATA SHEET 20157. 2 M/1430, BM/1430 General Information Model Sub-base Port size Weight Spares kit (kg) M/1430

2

M/1430, BM/1430

General InformationModel Sub-base Port size Weight Spares kit

(kg)M/1430 Side ported G1/8 0,54 QM/1430/00

BM/1430 Bottom ported G1/8 0,54 QM/1430/00

Time Delay Valve

19,5

14

19

27,5

39

22,5

295

2110

41

M16x1

4,5

4,5 32 4,5

14

10

265412

4,5

max

.11

9,5

min

.

19,5

24

14 18

G1

8/

‘3’

‘3’

‘12’

‘2’

15 15,5

Model Number: M/1430Port for additional reservoir shouldremain plugged when not used.Note: Nut used for locking functiononly, not for panel mounting.

Warning

These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceedthose listed under ‘Technical Data’.Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not withinpublished specifications, consult NORGREN MARTONAIR.Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider thefailure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment inthe event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot beadequately provided.System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.

5.11.021.02

Page 3: 13/07/15 TECH DATA SHEET 20157 - Flowtechnology UK · 13/07/15 TECH DATA SHEET 20157. 2 M/1430, BM/1430 General Information Model Sub-base Port size Weight Spares kit (kg) M/1430

3

M/1430, BM/1430

5.11.021.031/90

Time Delay Valve

19,5

14

19

27,5

39

295

2110

41

M16x1

4,5

4,5 32 4,5

14

10

265412

4,5

max

.11

9,5

min

.

19,5

24

‘3’

G1

8/

29

12

15

14

22

30

‘12’

‘2’

‘3’

Model Number: BM/1430Port for additional reservoirshould remain plugged when notused.Note: Nut used for lockingfunction only, not for panelmounting.

12

2

3