115 TO 3870 LPM -5 TO 850 GPM( FLOW RATES BM SERIES METERS - TOKICO … · 2020. 2. 7. · 115 to...

8
BM SERIES METERS ® PRECISION POSITIVE DISPLACEMENT METERS THE LEADER IN ACCURATE, LONG-LIFE, FUEL METERING INDUSTRY LEADING ACCURACY (+/- .05% * ) 110 TO 4000 LPM (30 TO 1000 GPM) FLOW RATES 105 Albrecht Drive Lake Bluff, IL 60044 +1 847.295.1050 +1 800.458.5262 AveryHardoll.com [email protected] * subject to meter size

Transcript of 115 TO 3870 LPM -5 TO 850 GPM( FLOW RATES BM SERIES METERS - TOKICO … · 2020. 2. 7. · 115 to...

Page 1: 115 TO 3870 LPM -5 TO 850 GPM( FLOW RATES BM SERIES METERS - TOKICO … · 2020. 2. 7. · 115 to 3870 lpm -5 to 850 gpm( flow rates bm series meters® precision positive displacement

115 TO 3870 LPM (25 TO 850 GPM) FLOW RATES

BM SERIES METERS®

PRECISION POSITIVE DISPLACEMENT METERS

THE LEADER IN ACCURATE, LONG-LIFE, FUEL METERING

INDUSTRY LEADING ACCURACY (+/- .05%*)

110 TO 4000 LPM (30 TO 1000 GPM) FLOW RATES

105 Albrecht Drive Lake Bluff, IL 60044

+1 847.295.1050+1 800.458.5262

AveryHardoll.com [email protected]

* subject to meter size

Page 2: 115 TO 3870 LPM -5 TO 850 GPM( FLOW RATES BM SERIES METERS - TOKICO … · 2020. 2. 7. · 115 to 3870 lpm -5 to 850 gpm( flow rates bm series meters® precision positive displacement

2 A V E R Y H A R D O L L . C O M

FEATURES & BENEFITSAvery-Hardoll BM Series flowmeters are precision made, positive displacement, liquid measuring instruments that maintain the higest level of accuracy over a lifetime of operation. Simplicity of design and accuracy has resulted in the Avery-Hardoll BM Series meters to being the most preferred meters by aviation fueling operators and airlines in internatonal markets.*

*According to the Global Aviation Fueling Survey 2015

THE MOST ACCURATE AVIATION FUEL METERS IN THE WORLD

Stainless steel bearings for maximum

operational life

Precision carbon vanes for maximum

measurement accuracy

Instrument grade machined rotor for perfect balance

Aluminium or Ni-Resist cast iron

outer covers

Cast and machined iron or

aluminum manifolds

Precision machined housing for perfect

seal and maxiumum measurement accuracy

Working pressure: 150 psi (10.3 bar)

Hydrostatic test pressure: 300 psi (20.7 bar)

Page 3: 115 TO 3870 LPM -5 TO 850 GPM( FLOW RATES BM SERIES METERS - TOKICO … · 2020. 2. 7. · 115 to 3870 lpm -5 to 850 gpm( flow rates bm series meters® precision positive displacement

FEATURES & BENEFITS

BM Series bulkmeters are manufactured in three basic sizes with different ratings identified by a series number. The series numbers, sizes, flow rates, and a brief description of each series of meter are shown below.

AVAILABLE MODELS

TYPES OF BULKMETER

Series NumberManifold Flow Rate

General DescriptionInches Millimeters

Imperial Gallons

Liters

BM250 2 - 2½ 63 25 - 250 115 - 1140Single Capsule Meters

BM950 3 76 30 - 300 130 - 1370

BM450 3 76 45 - 450 200 - 2050

Double Capsule MetersBM550 4 102 50 - 500 220 - 2280

BM350 4 102 55 - 550 250 - 2500

BM650 4 102 65 - 650 300 - 3000Triple Capsule Meters

BM750 6 152 65 - 650 300 - 3000

BM850 6 152 85 - 1000 387- 4000Special Application Only for Low

Viscosity / Clean Aviation Fuel

DIMENSIONAL DRAWINGSMECHANICAL METER ASSEMBLY DIAGRAM AND CROSS-SECTION

• The BM Series bulkmeters consist of three mainassemblies: the manifold, body assembly androtor assembly

• The higher rating of the larger meters is achievedby bolting two or three body capsules togetherand fitting double or triple rotor assemblies with alarger manifold to suit

• A calibrating mechanism and mechanical registerare also attached to the front end cover

• The calibrating mechanism can be replaced bya front cover incorporating a pulse transmitterwhen required for electronic systems, such asMASTERLOAD II™ or MASTERLOAD III™ registers

Rotor

Vane

Rod

Casing

Inlet

MeasuringCrescent

Inner Covers

Outer Covers

Calibrating Mechanism

Mechanical Register

Out & Inner Covers

Out & Inner Covers

Fabricated Steel Manifold (All Capsules)

Ductile Iron Manifold(Single/Double Capsule Only)

BULKMETER MAIN COMPONENTS

Cast andmachined iron or

aluminum manifolds

3A V E R Y H A R D O L L . C O M

Page 4: 115 TO 3870 LPM -5 TO 850 GPM( FLOW RATES BM SERIES METERS - TOKICO … · 2020. 2. 7. · 115 to 3870 lpm -5 to 850 gpm( flow rates bm series meters® precision positive displacement

Meter Series

Pipeline SizeFlow Rate Flanges

Imp. Gal. lpm M³/h Conform To Material

BM250 2-2½” (63mm) 25 to 250 115 to 1140 7 to 68 ASA 150 FF Ductile Iron Steel

BM950 3” (76mm) 30 to 300 130 to 1370 8 to 82 ASA 150 FF Ductile Iron Steel

Meter Series

Pipeline SizeFlow Rate Flanges

Imp. Gal. lpm M³/h Conform To Material

BM450 2-2½” (63mm) 25 to 250 115 to 1140 7 to 68 ASA 150 FF Ductile Iron Steel

BM550 3” (76mm) 30 to 300 130 to 1370 8 to 82 ASA 150 FF Ductile Iron Steel

BM350 4” (102mm)

55 to 550 250 to 2500 15 to 150 ASA 150 FF Ductile Iron Steel

615 2800 168 Intermittent Use

Meter Series

Pipeline SizeFlow Rate Flanges

Imp. Gal. lpm M³/h Conform To Material

BM650 4” (102mm) 65 to 650 300 to 3000 18 to 177 ASA 150 FF Steel

BM750 6” (152mm) 30 to 300 300 to 3000 18 to 177 ASA 150 FF Steel

BM850 6” (152mm) 85 to 1000 387 to 4000 23 to 232

ASA 150 FF Steel

Used on Aviation Kerosene

BM METERS SPECIFICATIONSPRECISION POSITIVE DISPLACEMENT BULK FUEL METERS

While conventional meters are calibrated at only one flow rate, MASTERLOAD II™ and MASTERLOAD III™ calibration is corrected at a range of flow rates to provide the highest level of accuracy. With a multitude of calibration points across the full flow range, the system allows the user the flexibility to configure each system to suit the requirements of their specific application.

Single Capsule Meter

Double Capsule Meter

Triple Capsule Meter

ELECTRONIC REGISTER CALIBRATION

4 A V E R Y H A R D O L L . C O M

Page 5: 115 TO 3870 LPM -5 TO 850 GPM( FLOW RATES BM SERIES METERS - TOKICO … · 2020. 2. 7. · 115 to 3870 lpm -5 to 850 gpm( flow rates bm series meters® precision positive displacement

5A V E R Y H A R D O L L . C O M

Flange Bolt Holes

Manifold Overall

Dimensions

Meter Dimensions Approx. Weight

of Basic MeterNo. Off

Size A B C D

mm. in. mm. in. mm. in. mm. in. mm. in. mm. in. kg. lbs.

4 4

19 19

.75

.75356 400

14 15.75

408 427

16.1 16.8

107 107

4.2 4.2

285 285

11.2 11.2

89 89

3.5 3.5 70 54

4 4

19 19

.75

.75356 400

14 15.75

408 427

16.1 16.8

107 107

4.2 4.2

285 285

11.2 11.2

95 95

3.75 3.75 70 54

Flange Bolt Holes

Manifold Overall

Dimensions

Meter Dimensions Approx. Weight

of Basic MeterNo. Off

Size A B C D

mm. in. mm. in. mm. in. mm. in. mm. in. mm. in. kg. lbs.

4 4

19 19

.75

.75400 400

15.75 15.75

405 427

15.9 16.8

170 170

6.7 6.7

348 348

13.7 13.7

95 95

3.75 3.75 100 220

8 8

19 19

.75

.75400 400

15.75 15.75

420 427

16.5 16.8

170 170

6.7 6.7

348 348

13.7 13.7

115 115

4.5 4.5 112 247

Flange Bolt Holes

Manifold Overall

Dimensions

Meter Dimensions Approx. Weight

of Basic MeterNo. Off

Size A B C D

mm. in. mm. in. mm. in. mm. in. mm. in. mm. in. kg. lbs.

8 19 .75 400 15.75 427 16.8 233 9.2 411 16.2 115 4.5 126 278

8 22 .875 400 15.75 427 16.8 233 9.2 411 16.2 140 5.5 136 300

BM METERS SPECIFICATIONS

Calibration adjustment is stepless, with no necessary gear changing. All meters are tested at a range of flow rates before dispatch. Test certificates available upon request.

• Fluid used for testing: Odorless kerosene

• Specific gravity: at 60/60°F, 15/15°C = 0.8

• Viscosity at 60°F, 15°C = 2.4 centistokes.

• Maximum working pressure: 150 psi (10.3 bar)

• Test pressure: 300 psi (20.7 bar)

• Temperature range: -28°C to 100°C

• Volume per revolution: - 2.27 litres (single capsule) - 4.54 litres (double capsule) - 6.82 litres (triple capsule)

• Typical accuracy: +/- 0.05%

• Repeatability: 0.02%

ELECTRONIC REGISTER CALIBRATION

MECHANICAL CALIBRATION WORKING SPECIFICATIONS

Typical accuracy curves for the basic meter build (10:1 turndown)

PHYSICAL CHARACTERISTICSDIMENSIONS AND CALIBRATION TESTING

Single Capsule Meter

Double Capsule Meter

Triple Capsule Meter

Page 6: 115 TO 3870 LPM -5 TO 850 GPM( FLOW RATES BM SERIES METERS - TOKICO … · 2020. 2. 7. · 115 to 3870 lpm -5 to 850 gpm( flow rates bm series meters® precision positive displacement

6 A V E R Y H A R D O L L . C O M

PERFORMANCEPERFORMANCE AND PRESSURE DROP CALCULATIONS

VISCOUS PRODUCTSPRESSURE DROP CHART (PSI)Avery-Hardoll bulkmeters can be used on all petroleum products of all viscosities. However, there is an increase in pressure drop with more viscous fuels, which under normal circumstances will limit the maximum flow rate obtainable.

It is recommended that the pressure drop through a bulkmeter should not exceed 15 psi (1 bar), above which the load on the bearings will start to cause wear.

Consequently when using products with viscosities above 100 centistokes (at operating conditions), it is necessary to reduce the maximum permitted flow rate. As a guide, it is suggested that the pressure drop through the meter should not exceed 10 psi (0.7 bar) for continuous running at maximum speed or 15 psi (1 bar) for continuous running at half speed.

The low pressure drop for the BM Series of Avery-Hardoll bulkmeters is displayed on the left.

2 Channel LC POD pulser

Viscosity of Liquid(At Temperature of Metering)

Page 7: 115 TO 3870 LPM -5 TO 850 GPM( FLOW RATES BM SERIES METERS - TOKICO … · 2020. 2. 7. · 115 to 3870 lpm -5 to 850 gpm( flow rates bm series meters® precision positive displacement

7A V E R Y H A R D O L L . C O M

PERFORMANCEPERFORMANCE AND PRESSURE DROP CALCULATIONS

VISCOUS PRODUCTS

ELECTRONICS REGISTRATION

ACCESSORIES

Avery-Hardoll bulkmeters can be used on all petroleum products of all viscosities. However, there is an increase in pressure drop with more viscous fuels, which under normal circumstances will limit the maximum flow rate obtainable.

It is recommended that the pressure drop through a bulkmeter should not exceed 15 psi (1 bar), above which the load on the bearings will start to cause wear.

Consequently when using products with viscosities above 100 centistokes (at operating conditions), it is necessary to reduce the maximum permitted flow rate. As a guide, it is suggested that the pressure drop through the meter should not exceed 10 psi (0.7 bar) for continuous running at maximum speed or 15 psi (1 bar) for continuous running at half speed.

The low pressure drop for the BM Series of Avery-Hardoll bulkmeters is displayed on the left.

Temperature Volume Compensation (TVC)

Automated Fueling - Wireless Data System(for MASTERLOAD III™ or LCR 600)

2 Channel LC POD pulser 3 Channel Avery-Hardoll Pulser Large Digital Remote Display Paper Receipt Printer

REGISTRATION & ACCESSORIES

Differential Pressure Transducer

A highly accurate and versatile microprocessor-based electronic controller. The industry standard in simplicity and reliability for aviation fueling applications.

MASTERLOAD II™ REGISTER

MASTERLOAD III™ REGISTER • Increased accuracy with multi-point calibration

• Easy to operate along with secure protected data

• Automated fueling with FlightConnect® (option)

• Long-life durability in harsh environments

Page 8: 115 TO 3870 LPM -5 TO 850 GPM( FLOW RATES BM SERIES METERS - TOKICO … · 2020. 2. 7. · 115 to 3870 lpm -5 to 850 gpm( flow rates bm series meters® precision positive displacement

BMSeriesBrochure_Rev0916

© Copyright 2016 Liquid Controls LLC All Rights Reserved.

L I Q U I D C O N T R O L SLiquid Controls offers a full range of:

• M Series Meters

• MS Series Meters

• Electronic Registration

• Valves

• Air Eliminators & Strainers

• Fueling Accessories

• Wireless Data Management

To learn more about what LC can offer you visit: LCMeter.com

To learn more about Avery-Hardoll products, visit: AveryHardoll.com

BULK FUEL FLOWMETERS

ELECTRONIC REGISTRATION

Distributed by:

MASTERLOAD III™ is an advanced dual microprocessor based electronic meter register for Zone 1 hazardous areas that is “FlightConnect Ready” for automated fueling and wireless data reporting.

MASTERLOAD II™ is an intrinsically safe microprocessor based electronic controller that enhances the performance and operation of positive displacement and turbine meters.

Avery-Hardoll flowmeters are precision made, positive displacement, liquid measuring instruments; considered the most accurate aviation fuel flowmeters in the world.

Liquid Controls proudly manufactures the Avery-Hardoll and LC brand meters and is the leading manufacturer of positive displacement flowmeters and fuel data management systems in the world.