10Gb/s DWDM SFP+ 40km Transceiver RDPX0SER · Rev. A.2 5, 07/19/2013 RDPX0SER DWDM SFP+ Transceiver...
Embed Size (px)
Transcript of 10Gb/s DWDM SFP+ 40km Transceiver RDPX0SER · Rev. A.2 5, 07/19/2013 RDPX0SER DWDM SFP+ Transceiver...
-
RoHS Compliant
Rev. A.5, 07/19/2013 1
Features
RoHS compliant
Support multi protocol from 9.9Gb/s to 11.3 Gb/s
Compliant with SFP+ MSA, SFF 8431 Rev. 4.1
Compliant with SFF 8432 Rev.5.0 mechanical
dimension
Compliant with Digital diagnostic SFF-8472
Rev.11.0
Transmission distance of 40km over single mode
fiber
C-band DWDM EML laser transmitter
LC duplex connector
Hot pluggable 20 pin connector
Single power supply voltage : +3.3V
Low power dissipation
Three optional operating temperature ranges :
Option ST : 0C to 70C
Option ET : -5C to 85C
Option IT : -40C to 85C
Applications
SONET OC-192 IR-2 / SDH L-64.2b
10GBASE-ER
10G Fiber channel
G.709 OUT-2
Description
OE Solutions Small Form Factor Pluggable
(SFP+) transceivers are compatible with the
Small Form Factor Pluggable 20pin Multi-
Source Agreement (MSA). The high performance
cooled DWDM EML transmitter and high
sensitivity PIN receiver provide superior
performance for SONET/SDH and Ethernet
applications up to 40km optical links.
Enhanced Digital Diagnostics functions are
available via the 2-wire serial bus specified in the
SFF-8472 Rev. 11.0. The transmitter and receiver
features ac-coupled differential data inputs and
outputs, and an LVTTL for Tx disable input and
Tx fault output. Software TX disable is also
implemented. The receiver features differential
ac-coupled data outputs and LVTTL for LOS
(Loss of Signal) output.
10Gb/s DWDM SFP+ 40km Transceiver
RDPX0SER
-
Rev. A.5, 07/19/2013 2
RDPX0SER DWDM SFP+ Transceiver Product Specifications
1. Absolute Maximum Ratings
Parameter Symbol Min. Typ. Max. Unit Notes
Absolute Supply Voltage Vcc_max 0 - 3.6 V -
Operating Case Temperature Top -40 - 85 C 1,3
Operating Relative Humidity RHop 5 - 90 % 2
Storage and TransportationTemperature Tst -40 - 85 C 2
Storage and Transportation
Relative Humidity
5 - 95 % 2
Notes: 1. Measured on top side front center of SFP module 2. Non-condensing 3.There are three options of operating maximum temperature:
Option ST: standard temperature from 0oC to 70
oC,
Option ET: extended temperature from -5oC to 85
oC
Option IT: extended temperature from -40oC to 85
oC
2. General Operating Conditions
Parameter Symbol Min. Typ. Max. Unit Notes
Bit Rate B 9.9 10.3 11.3 Gb/s -
Maximum Transmission Distance Dmax 80 - - km -
Operating Voltage Vcc 3.14 - 3.46 V -
Power Supply Current ICC - - 550 mA ST
- - 725 mA ET, IT
Total Power Consumption - - 2.5 W -
ESD (High speed pins) - - 500 V 2
Notes : 1. Supplies TEC, Current draw depends on Temperature 2. Human body model per JEDEC JESD22-A114-B, compliant with INF-8077i Rev. 4.5 August 31, 2005
-
Rev. A.5, 07/19/2013 3
RDPX0SER DWDM SFP+ Transceiver Product Specifications
3. Electrical Specifications
3.1 Transmitter Electrical Specifications (Over Operating Case Temperature and Power Supply Range)
Electrical Characteristics
Parameter Symbol Min. Typ. Max. Unit Notes
Differential Input Impedance Rin 80 100 120 -
Differential Data Input Swing Vin,pp 180 - 700 mVp-p -
Data Input Rise/Fall Time tr/tf 15 - 40 ps
Tx Disable Voltage Vd 2.0 - Vcc+0.3 V 1
Tx Enable Voltage Ven 0 - 0.8 V -
Tx Fault Output Low Vtfl - - 0.4 V -
Tx Disable Assert Time T_off - - 100 s -
Tx Enable Assert Time T_on - - 2 ms -
Tx Fault Assert Time Tx_f_on - - 1 s -
Tx Fault Reset Time Tx_reset 10 - - s -
Initialization Time T_start_up_cooled - - 90 s -
Note : 1. Vcc is the voltage of host board
3.2. Receiver Electrical Specifications (Over Operating Case Temperature and Power Supply Range)
Electrical Characteristics
Parameter Symbol Min. Typ. Max. Unit Notes
Data Rate B 9.9 10.3 11.3 GBd -
Differential Output Impedance Rout 80 100 120 -
Differential Data Output Swing Vout 350 - 800 mVp-p -
Data Output Rise/Fall Time tr/tf - - 45 ps -
LOS Output High Voltage Vlosh Vcc-0.5 - Vcc+0.3 V 1
LOS Output Low Voltage Vlosl 0 - 0.4 V -
LOS Assert/Deassert Time Delay T_los on/off - - 100/100 s/s -
Note : 1. Vcc is the voltage of host board
-
Rev. A.5, 07/19/2013 4
RDPX0SER DWDM SFP+ Transceiver Product Specifications
4. Optical Specifications
4.1 Transmitter Optical Specifications (Over Operating Case Temperature and Power Supply Range)
Optical Characteristics
Parameter Symbol Min. Typ. Max. Unit Notes
Laser Safety Class Class 1 according to IEC60825 -
Optical Wavelength 1529 - 1562 nm -
Average Optical
Output Power
BOL Pout -1 - +3 dBm 1
EOL -2 - +3
Optical Power Overshoot Pov - - 1 dB 2
Optical power of OFF transmitter Pout-off - - -40 dBm -
Spectral Width -8 - 8 GHz 3
Optical Output Power Variation
(with respect to BOL Tc=25C,
and nominal power supply)
Pout -1 - +1 dB -
Side Mode Suppression Ratio SMSR 35 - - dB 4
Wavelength
Deviation
BOL T -50 - +50 pm 5
EOL a -100 - +100 pm
Optical Extinction Ratio ER 8.2 - - dB -
Optical Rise/Fall Time (20%-80%) Tr, Tf - - 35 ps -
Output Jitter - - - - 6
Date Rate 9.95 10.7 11.05 11.35 Gb/s
Path Penalty 10-3
BER 3 3.5 4
dB 7 10-4
BER 3 3.5 4
10-12
BER 2
Notes: 1. Average power measured at output 2. Defined as Peak power Steady-state power (in dBm) when Tx-dis is de-asserted or when the module is hot plugged with Tx_dis in low state (Tx enabled). 3. Full spectral width (RBW=0.1nm) measured 15dB down from the maximum of center wavelength peak under full modulation condition 4. Ratio of the average output power in the dominant longitudinal mode to the power in the most significant side mode peak under full modulation condition 5. Deviation related to the ITU standardized wavelength. The EOL value is met as soon as the output average power is above 10% of the steady-state power. 6. The jitter performance meets Telcodia GR-253-Core and ITU-T Recommendations G.783, G813, G825 and G82511 with ITU-T 0.172(04/2005) for the measurement methods and the measurement equipment. 7. -500 to 800ps/nm
Laser Safety: All transceivers in this datasheet are Class I Laser products per FDA/CDRH and IEC-60825 standards. They must be operated under specified operating conditions.
-
Rev. A.5, 07/19/2013 5
RDPX0SER DWDM SFP+ Transceiver Product Specifications
4. ITU Channel and Wavelength Guide
ITU Channel Frequency
(THz)
Wavelength
(nm) ITU Channel
Frequency
(THz)
Wavelength
(nm)
39 193.9 1546.12
40 194.0 1545.32
17 191.7 1563.86 41 194.1 1544.53
18 191.8 1563.05 42 194.2 1543.73
19 191.9 1562.23 43 194.3 1542.94
20 192.0 1561.42 44 194.4 1542.14
21 192.1 1560.61 45 194.5 1541.35
22 192.2 1559.79 46 194.6 1540.56
23 192.3 1558.98 47 194.7 1539.77
24 192.4 1558.17 48 194.8 1538.98
25 192.5 1557.36 49 194.9 1538.19
26 192.6 1556.56 50 195.0 1537.40
27 192.7 1555.75 51 195.1 1536.61
28 192.8 1554.94 52 195.2 1535.82
29 192.9 1554.13 53 195.3 1535.04
30 193.0 1553.33 54 195.4 1534.25
31 193.1 1552.52 55 195.5 1533.47
32 193.2 1551.72 56 195.6 1532.68
33 193.3 1550.92 57 195.7 1531.90
34 193.4 1550.12 58 195.8 1531.12
35 193.5 1549.32 59 195.9 1530.33
36 193.6 1548.51 60 196.0 1529.55
37 193.7 1547.72 61 196.1 1528.77
38 193.8 1546.92
-
Rev. A.5, 07/19/2013 6
RDPX0SER DWDM SFP+ Transceiver Product Specifications
4.2. Receiver Optical Specifications (Over Operating Case Temperature and Power Supply Range)
Optical Characteristics
Parameter Symbol Min. Typ. Max. Unit Notes
Optical Wavelength 1528 1563 nm -
Average Rx [email protected] RSENS - - -15.8 dBm 1
Maximum Input Power Pol -1.0 - - dBm -
Rx [email protected] (OMA) - - - -14.1 dBm 2
Stressed [email protected] (OMA) - - - -11.3 dBm 3
Receiver Reflectance - - - -26 dB -
LOS Assert LOS_A -30 - - dBm -
LOS De-assert LOS_D - - -16 dBm -
LOS Hysteresis - - 2 5 dB -
Notes : 1. Measured with a PRBS of 231
-1 at 1 x 10-12
BER and 3 dB extinction ratio
-
Rev. A.5, 07/19/2013 7
RDPX0SER DWDM SFP+ Transceiver Product Specifications
5. Pin Descriptions
SFP Transceiver Electrical Pad Layout
Tx GND
TD-
TD+
Tx GND
VccT
VccR
Rx GND
RD+
RD-
Rx GND
Tx Fault
Tx Disable
SDA
RS0
Rx_LOS
RS1
Rx GND
SCL
Mod_ABS
20
19
18
17
16
15
14
13
12
11
1
2
3
4
5
6
7
8
9
10
Top of Board Bottom of Board
Tx GND
-
Rev. A.5, 07/19/2013 8
RDPX0SER DWDM SFP+ Transceiver Product Specifications
Pin Descriptions (continued)
Pin Logic Symbol Description Plug Seq. * Notes
1 - Tx GND Transmitter Ground 1 1
2 LVTTL-O Tx Fault Transmitter Fault Indication 3 2
3 LVTTL-I Tx Disable Transmitter Disable 3 3
4 LVTTL-I/O SDA 2 wire Serial Interface Data Line 3 4
5 LVTTL-I/O SCL 2 wire Serial Interface Clock 3 4
6 -
MOD_ABS Module Absent, connected to Tx GND or Rx GND in the module
3 5
7 LVTTL-I RS0 Rate Select 0, not used 3 6
8 LVTTL-O Rx LOS Receiver Loss of Signal Indication (In FC designated as Rx_LOS and in Ethernet designated as Signal Detect Bar
3 7
9 LVTTL-I RS1 Rate Select 1, not used 3 6
10 - Rx GND Receiver Ground 1 1
11 - Rx GND Receiver Ground 1 1
12 CML-O RD- Receiver Negative Data Out 3 -
13 CML-O RD+ Receiver Positive Data Out 3 -
14 - Rx GND Receiver Ground 1 1
15 - Vcc Rx Receiver Power, 3.3V5% 2 -
16 - Vcc Tx Transmitter Power, 3.3V5% 2 -
17 - Tx GND Transmitter Ground 1 1
18 CML-I TD+ Transmitter Positive Data In 3 -
19 CML-I TD- Transmitter Negative Data In 3 -
20 - Tx GND Transmitter Ground 1 1 *Plug Seq. : Pin engagement sequence during hot plugging Notes : 1. The module ground contacts, Tx GND abd Rx GND, shall be isolated frim the module case, that is, frame ground. 2. Tx Fault is an open collector/drain output that shall be pulled up with a 4.7k ~ 10k on the host board. Pull up voltage
between 2.0V and VccT + 0.5V. When high, output indicates a laser fault of some kind. When low, output indicates normal operation. The LD output is not turned off in case of Tx Fault
3. Tx Disable is an input that is used to shut down the transmitter optical output. It is pulled up within the TRx with a 4.7k ~ 10k to VccT.
4. SDA and SCL should be pulled up with a 4.7k ~ 10k on the host board. The pull-up voltage shall be VccT. SCL is the clock line of 2-wire serial interface for serial ID. SDA is the data line of 2-wire serial interface for serial ID.
5. Mod_ABS is connected to Tx GND or Rx GND in the SFP+ module. The host may pull the contact up to Vcc on the host board with a resistor in the range 4.7 ~ 10k. Mod_ABS is asserted high when the SFP+ module is physically absent from a host slot. In the SFP MSA (INF-8074i) this contact has the same function but is called MOD_DEF0.
6. RS0 and RS1 are module input rate select contacts and are pulled low to Tx GND with a >30k resistor in the module. RS0 is an input hardware contact which optionally selects the optical receive data path rate coverage for an SFP+ module. RS1 is an input hardware contact which optionally selects the optical transmit path data rate coverage for the SFP+ module. These contacts can also be used for AS0 and AS1 if implementing SFF8079. RS1 is commonly connected to Tx GND or Rx GND in the classical SFP modules. The host needs to ensure that it will not be damaged if this contact is connected to Tx GND or Rx GND in the module. For logical definitions of RS0/RS1, see Section 2.5 of SFF-8431 Rev. 2.1.
7. LOS is an open collector output. Shall be pulled up with a 4.7k ~ 10k on host board. Pull up voltage between 2.0 and VccR+0.3. Logic 0 indicates normal operation.
-
Rev. A.5, 07/19/2013 9
RDPX0SER DWDM SFP+ Transceiver Product Specifications
5. Outline Drawings
Dimensions are in millimeters
-
Rev. A.5, 07/19/2013 10
RDPX0SER DWDM SFP+ Transceiver Product Specifications
6. PCB layout and Bezel recommendation
Dimensions are in inches (millimeters)
Notes : 1. Datum and basic dimensions established by customer.
2. Pads and vias are chassis ground, 11 locations
3. Thru holes, plating optional.
-
Rev. A.5, 07/19/2013 11
RDPX0SER DWDM SFP+ Transceiver Product Specifications
7. PCB layout and Bezel recommendation (continued)
Notes : Thru holes, plating optional.
Recommended Panel Opening
-
Rev. A.5, 07/19/2013 12
RDPX0SER DWDM SFP+ Transceiver Product Specifications
8. SFP+ Block Diagram, Power Supply Information and Host Board Interface
8.1 SFP+ Block Diagram
TOSA
TOSA
Laser
driver
Post amp.
Vcc Tx
Tx_GND
LOS
RD-
RD+
TD+
TD-
Tx Disable
Tx Fault
SCL
SDA EEPROM
10k
100
Management processor
Vcc Rx
Rx_GND
Zin diff.=
100
Zout = 50
each arm
Pin 16
Pin 3
Pin 18
Pin 19
Pin 2
Pin 1, 17, 20
Pin 5
Pin 4
Pin 15
Pin 12
Pin 13Pin 8
Pin 10, 11, 14
RS0
RS1
Pin 7
Pin 9
Mod ABS Pin 6
-
Rev. A.5, 07/19/2013 13
RDPX0SER DWDM SFP+ Transceiver Product Specifications
8.2 Recommended Host Board Supply Filtering Network
8.3 SFP+ Host Board Interface
Note 1: Host board output device circuit in the transmitter side and host board input device circuit in the receiver should be
carefully designed to meet 100ohm differential impedance matching. Also necessary is the dc bias circuit of each
input and output by taking into account of ac coupling of data input ant output of SFP+ module. For the interface of
host board devices, it is recommended to refer to the device vendors data sheet.
1H
1H
0.1F
0.1F
10F 10F 0.1F
Vcc +3.3V
SFP+ Module
Vcc Tx
Vcc Rx
HOST BOARD
Tx GND
Rx GND
Host Board GND
1 Tx GND
2 Tx Fault
3 Tx Disable
4 SDA
5 SCL
6 Mod ABS
7 RS0
8 Rx LOS
9 RS1
10 Rx GND
Tx GND 20
TD- 19
TD+ 18
Tx GND 17
Vcc Tx 16
Vcc Rx 15
RX GND 14
RD+ 13
RD- 12
Rx GND 11
10k
Vcc
10k
Vcc
10k
Vcc
10k
Vcc
10k
Vcc
Host board
Device
Host board
Device
Differential 100(note 1)
Differential 100(note 1)
Refer to Section 8.2
SFP+ Module
-
Rev. A.5, 07/19/2013 14
RDPX0SER DWDM SFP+ Transceiver Product Specifications
9. Digital Diagnostic Monitoring and Serial ID Operation
The information is accessed through the pin 4 (SDA), and pin 5(SCL) of the module. The device
address used to read the Serial ID data is 1010000X(A0h), and the address to read the diagnostic data is
1010001X(A2h). The EEPROM Write Protect pin is internally tied to ground with no external access,
allowing write access to the customer-writable field (bytes 128-247 of address 1010001X). Address
bytes 0-127 are not write protected and may cause diagnostic malfunctions if overwritten.
The information stored in the EEPROM, including the organization and the digital diagnostic
information, is defined in the Small Form-Factor document SFF-8472 Rev. 11.0, dated September,
2010.
9.1 Data Field Descriptions, and Serial ID Data and Map
9.2 Serial ID and Map: page A0h
Address HEX Name of Fields Description
0 03 Identifier SFP+
1 04 Ext. Identifier GBIC/SFF function is defined by serial ID only
2 07 Connector LC
3 80 10G Ethernet Compliance 10GBASE-ER
4 00 Reach Specifier
5 00 SONET
6 00 Gigabit Ethernet
7 00 Fiber Channel link length Unallocated
8 10 Transmitter technology Longwave Laser (LL)
9 01 Transmission media Single Mode (SM)
10 00 Fiber Channel Speed
Address(1010000X) (A0h) Address(1010001X) (A2h)
Serial ID Information:
Defined by SFP MSA
OE Solution Specific
Information
Reserved for SFP MSA
Alarm and Warning Limits
Reserved for External
Calibration Constants
Real Time Diagnostic
Information
OE Solutions Specific
Information
OE Solutions Specific Information
Non-volatile, customer-
writeable, field-writeable
area
0
95
127
255 255
247
119
127
95
0
55
-
Rev. A.5, 07/19/2013 15
RDPX0SER DWDM SFP+ Transceiver Product Specifications
11 06 Encoding 64B/66B
12 67 Nominal Bit Rate 10.30 Gbps
13 00
14 28 Length(9u)[km] 40 Km
15 FF
16 00 Length(50u,OM2)[m] Not support
17 00 Length(62.5u,OM1)[m] Not support
18 00 Length(copper) Not support
19 00 Length(50u,OM3)[m] Not support
20 4F
Vendor Name
O
21 45 E
22 20
23 53 S
24 4F O
25 4C L
26 55 U
27 54 T
28 49 I
29 4F O
30 4E N
31 53 S
32-35 20
36 00 Reserved
37 00
Vendor OUI
00
38 19 19
39 3A 3A
40 52
Vendor PN
R
41 44 D
42 50 P
43 58 X
44 30 0
45 53 S
46 45 E
47 52 R
48 2D -
49 xx xx = (5Ah for ST, 45h for ET, 49h for IT)
50 xx xx=(32h:2,33h:3,34h:4,35h:5,36h:6)
51 xx xx=(30h:0, 31h:1, 32h:2,33h:3,34h:4,35h:5,36h:6,37h:7,
38h:8, 39h:9)
52-55 20
56 30
Vendor Rev.
0
57 31 1
58 2E .
59 varies varies
60
Note 1 Wavelength[nm]
61
62 Wavelength(@10pm)
63 Varies CC_BASE Checksum over 0 to 62
64 06
Option Values
Cooled Transceiver[2]
Power Level[1]
Linear Receiver Output[0]
Cooled Laser implementation
Power Level 2
-
Rev. A.5, 07/19/2013 16
RDPX0SER DWDM SFP+ Transceiver Product Specifications
65 1A
Option Values
Rate Select[5]
Tx Disable[4]
TX Fault[3]
SD[2]
LOS[1]
Tx Disable[4]
TX Fault[3]
LOS[1]
66 00 Bit Rate, max[%] Not Specified
67 00 Bit Rate, min[%] Not Specified
68-83 Varies Vendor S/N Varies
84-91 Varies Date Code Varies
92 68
Diagnostic Monitoring Type
Digital diagnostic[6]
Internally Cailbrated[5]
Externally Calibrated[4]
Average Power[3]
Address change req[2]
Digital diagnostic[6]
Internally Calibrated[5]
Average Power[3]
93 F0
Enhanced Options
Alarm/Warm Impl.[7]
Soft TX Dis Control[6]
Soft TX Fault monitor[5]
Soft Rx LOS monitor[4]
Soft RATE_SEL Control[3]
App Select Control[2]
Rate Select Control[1]
Alarm/Warm Impl.[7]
Soft TX Dis Control[6]
Soft TX Fault monitor[5]
Soft Rx LOS monitor[4]
94 05 SFF-8472 Compliance Rev 11.0 of SFF-8472
95 Varies CC_EXT Check Sum Byte for Bytes 64 to 94
96-127 00 Vendor Specific
128-163 Varies OES'DATA OES'DATA
164-247 00 Reserved Reserved
248-255 Varies OES'DATA OES'DATA
Note 1. 16-bit integer value in nm with byte 60 as high byte, byte 61 as low byte. The fractional part of the
wavelength in units of 0.01nm written in byte 62. Varies
9.3. Page A2 HEX
Address HEX Name of Fields Description
0 49/58 Temp High Alarm ST:73.00/ET,IT:88.00
1 00
2 F8/D5 Temp Low Alarm ST,ET:-8.00/IT:-43.00
3 00
4 46/55 Temp High Warning ST:70.00/ET,IT:85.00
5 00
6 FB/D8 Temp Low Warning ST,ET:-5.00/IT:-40.00
7 00
8 8C Voltage High Alarm 3.60
9 A0
10 75 Voltage Low Alarm 3.00
-
Rev. A.5, 07/19/2013 17
RDPX0SER DWDM SFP+ Transceiver Product Specifications
11 30
12 87 Voltage High Warning 3.47
13 8C
14 79 Voltage Low Warning 3.10
15 18
16 EA Bias High Alarm 120.00
17 60
18 4E Bias Low Alarm 40.00
19 20
20 D6 Bias High Warning 110.00
21 D8
22 61 Bias Low Warning 50.00
23 A8
24 7B Tx High Alarm 5.00
25 87
26 13 Tx Low Alarm -3.00
27 94
28 4D Tx High Warning 3.00
29 F1
30 1F Tx Low Warning -1.00
31 07
32 27 Rx High Alarm 0.00
33 10
34 00 Rx Low Alarm -17.00
35 C8
36 1F Rx High Warning -1.00
37 07
38 01 Rx Low Warning -15.00
39 3C
40-55 00 Reserved
56 00
Rx PWR(4) 0.00 57 00
58 00
59 00
60 00
Rx PWR(3) 0.00 61 00
62 00
-
Rev. A.5, 07/19/2013 18
RDPX0SER DWDM SFP+ Transceiver Product Specifications
63 00
64 00
Rx PWR(2) 0.00 65 00
66 00
67 00
68 3F
Rx PWR(1) 1.00 69 80
70 00
71 00
72 00
Rx PWR(0) 0.00 73 00
74 00
75 00
76 01 Bias (Slope) 1.00
77 00
78 00 Bias (Offset) 0.00
79 00
80 01 Tx Power (Slope) 1.00
81 00
82 00 Tx Power (Offset) 0.00
83 00
84 01 Temp (Slope) 1.00
85 00
86 00 Temp (Offset) 0.00
87 00
88 01 Vcc (Slope) 1.00
89 00
90 00 Vcc (Offset) 0.00
91 00
92 00
Reserved
93 00
94 00
95 xx Checksum Checksum over 0 to 94
96 00 Temperature MSB
97 00 Temperature LSB
98 00 Vcc MSB
99 00 Vcc LSB
-
Rev. A.5, 07/19/2013 19
RDPX0SER DWDM SFP+ Transceiver Product Specifications
100 00 TX Bias MSB
101 00 TX Bias LSB
102 00 TX Power MSB
103 00 TX Power LSB
104 00 RX Power MSB
105 00 RX Power LSB
106 00
107 00
108 00
109 00
110 00
Optional Status
Tx Disable Input[7]
Soft TX Disable[6]
RX Rate Select State[4]
Tx Fault Output[2]
Loss of Signal Output[1]
Data_Ready_Bar[0]
111 00
112 00
Alarm Flag
Temp High Alarm[7]
Temp Low Alarm[6]
Vcc High Alarm[5]
Vcc Low Alarm[4]
TX Bias High Alarm[3]
TX Bias Low Alarm[2]
TX Power High Alarm[1]
TX Power Low Alarm[0]
113 00 RX High Alarm[7]
RX Low Alarm[6]
114 00
115 00
-
Rev. A.5, 07/19/2013 20
RDPX0SER DWDM SFP+ Transceiver Product Specifications
116 00
Warning Flag
Temp High Warning[7]
Temp Low Warning[6]
Vcc High Warning[5]
Vcc Low Warning[4]
TX Bias High Warning[3]
TX Bias Low Warning[2]
TX Power High Warning[1]
TX Power Low Warning[0]
117 00 RX High Warning[7]
RX Low Warning[6]
118 00
119 00
120-127 00 Vendor Specific
128-247 00 User EEPROM
248-255 00 Vendor Specific
9.4 Diagnostics
The enhanced digital diagnostics feature monitors five key transceiver parameters which are internally
calibrated and should be read as absolute values.
A2h address Parameter Calibration Accuracy Range
96-97 Temperature Internal +/- 3oC Note 1
98-99 Vcc Internal +/- 3% 3.13 to 3.47
100-101 Tx bias Internal +/- 10% Note 2
102-103 Tx power Internal +/- 2dB -2 to +3Bm
104-105 Rx Power Internal +/- 2dB -24 to -7dBm
Note: 1) Junction temperature of temperature sensing device. Monitoring range is from -40oC to 125
oC.
2) Specified by nominal value
10. Regulatory Compliance
RDPX0SER comply with international Electromagnetic Compatibility (EMC) and international safety
requirements and standards. EMC performance is dependent on the overall system design. The RDPX0SER is
lead-free and RoHS-compliant per Directive 2011/65/EU of the European Parliament and of the Council of 8
June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment.
-
Rev. A.5, 07/19/2013 21
RDPX0SER DWDM SFP+ Transceiver Product Specifications
11. Ordering Information
Model Name OES P/C
Operating Case
Temperature
Nominal Wavelength
Latch Color
Application Distance
RDPX0SER-Sxx Gxx05 0oC to 70oC
C-band
DWDM
(See Section 4)
Red SONET/SDH & 10G GbE 40km
RDPX0SER-Exx TBD -5oC to 85oC
C-band
DWDM
(See Section 4)
Red SONET/SDH & 10G GbE 40km
RDPX0SER-Ixx TBD -40oC to 85oC
C-band
DWDM
(See Section 4)
Red SONET/SDH & 10G GbE 40km
Notice: This data sheet is subject to change at any time without notice.
Revision History
Date Rev. # Description Author(s)
12/09/2011 Rev.A.0 first Release JSYU
01/07/2012 Rev.A.1 10GBASE-ER Compliance specified in Byte 3
Fiber Channel Technology in Byte 8
JSYU
11/05/2012 Rev.A.2 EEPROM corrections of A0H
Addr 64: 04->06
Addr 65: 3A->1A
A2H content added
JSYU
11/17/2012 Rev.A.3 Typo(Optical Extinction Ratio (Unfiltered) Optical Extinction Ratio) JSYU
01/08/2013 Rev.A.4 ET,IT Temp added JSYU
07/19/2013 Rev.A.5 Total Current changed
(ET,IT : 700mA 725mA)
JSYU
Contact Information:
OE Solutions Co. Ltd. (Korea) Techno Park, 958-3, Daechon-Dong, Buk-Gu, Gwangju, Korea, 500-470. Tel: +82-62-602-7813, Fax: +82-62-602-7639, www.oesolution.com.
OE Solutions America, Inc. 560 Sylvan Avenue, 1
st Floor, Englewood Cliffs, NJ 07632
Tel: 201-568-1188 Fax:201-568-1177Tel: +1-201-224-2377, Fax: 1-949-272-3200
http://www.oesolution.com/