1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation...

22
1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex detector G. Pellegrini M. Lozano G. Pellegrini D. Quirion M. Fernández R. Jaramillo F.J. Muñoz I. Vila T. Rohe

Transcript of 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation...

Page 1: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

1

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

3D Double-Sided sensors for the CMS phase-2 vertex detector

3D Double-Sided sensors for the CMS phase-2 vertex detector

G. Pellegrini

M. LozanoG. PellegriniD. Quirion

M. FernándezR. JaramilloF.J. MuñozI. Vila

T. Rohe

Page 2: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

2

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Outline

Motivation 3D pixel technology and manufacturing Electrical characterization PSI46 Read Out Chip (ROC) and interconnections Radiation resistance studies Summary

Page 3: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

3

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Motivation

New generation of vertex detectors must deal with fluences about 1*10¹⁶ neq/cm²

Here we are going to assess the radiation resistance of 3D double-sided pixel sensors in terms of: Increase of the depletion voltage (Vfd) Reduction of the CCE

- LHC experiments are expected to undergo a constant increase of radiation levels, a possible HL-LHC scenario will get things tougher

Page 4: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

4

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

CNM Production and Description

6 wafers:Wafers 5,6,7,8:

- 285 μm thicknessWafer 11:

-230 μm thicknessWafer 3:

- 285 μm thickness- Resistor bias grid

Each wafer includes:

•1 Full Module (8x2)•20 Single Chips•8 Strip sensors•12 Pad•Test structures

Page 5: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

5

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Electrical characterization

Measured Vfd (pad) ~ 1.5 V

Using Coaxial approximation,Extrapolating to sensor geom:

Vfd (3D-Detector) ~ 9 V

- Very Homogeneous behavior

- Current Values in the expected range

100nA

Page 6: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

6

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors Electrical measurements

MC Devices (8x2 detectors)

Largest 3D det. ever fabricated? 6.7 x 1.8cm2

Page 7: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

7

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

A grid of polysilicon resistor was implemented for direct testing of pixels before flip-chip

• 2 extra mask level needed

• Rsq~1MΩ (defined by ion implantation)

Polysilicon resistors

Page 8: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

8

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Biasing studies. Wafer 3

Same meas.

Only guard connected → “punch through” polarizationOnly bias connected → pixel by pixel polarization

Page 9: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

9

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Full module has been designed with sparse pattern and single guard ring

* In the back side, two columns pattern.- Dense → reduced drift distance

Expected higher radiation resistance-Sparse → larger drift distance

Expected lower noise (lower capacitance)

Sparse and dense pattern

Page 10: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

10

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Bump bonding and CCE measurements done at PSI

Page 11: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

11

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors Scanning electron Microscope

SEM

Page 12: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

12

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

- Bum bonding yield test- Using a 90Sr radioactive source- An uniform pattern has been observed. Including the holes on the PCB (between sensor and scintillator)

CCE measurements done at PSI by F.J. Muñoz

Bump bonding

Page 13: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

13

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

In other cases:

Reason: There are passivation layers only in one side of the wafer (overlooked during production)

Problem: The stress during the second re-flow process, bows the Sensor breaking the bumps connections

Provisional Solution: To put some weight on top of the sensor-chip “sandwich” during 2nd reflow.

Page 14: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

14

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Nice Pixel map, and landau fit:

MPV ~ 22 ke⁻

Page 15: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

15

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Irradiation Campaign:

- Proton Cyclotron @ KIT (Karlsruhe), 25MeV protons:

1 x 10¹⁵ neq

/cm²5 x 10¹⁵ n

eq/cm²

- Tigra Reactor @ JSI (Ljubljana), continuous spectrum neutrons:

1 x 10¹⁵ neq

/cm²5 x 10¹⁵ n

eq/cm² (ongoing)

1 x 10¹⁶ neq

/cm²

4 pixel samples, 2 strips detectors and 2 pads up to each radiation fluence

Page 16: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

16

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Charge Collection in irradiated samplesFull Depletion Voltage:

- Depletion Area grows in a 3D sensor horizontally- A new variable:

Er =

- When the Er saturates with bias voltage, we consider that we have depleted the maximum volume in the sensor

Num. of hits

Num. of triggers

90Sr Characterization

Page 17: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

17

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

F= 1*10¹⁵ neq/cm²

2 samples with protons2 samples with neutrons

MPV vs bias Voltage in irradiated samples

No annealing

Page 18: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

18

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Vfd=120 V

F= 1*10¹⁵ neq/cm²

Er

2 samples with protons2 samples with neutrons

Er vs bias Voltage in irradiated samples

Page 19: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

19

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

Vfd=180 V

F= 5*10¹⁵ neq/cm²protons

Er

MPV and Er vs bias Voltage in irradiated samples

Page 20: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

20

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

MPV vs FluenceV

fd =20V

Vfd =120V

Vfd =180V

Page 21: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

21

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

FUTURE WORK:

- Studies on the ROC performance after 1*10¹⁶ neq/cm²- Test Beam @ DESY in March (Tracking Eff.)- Capacitance meas. In the two different patterns

CONCLUSIONS:

- Sensors show a good performance up to 5*10¹⁵ neq/cm²

- Mechanical stress reduces the bump-bonding yield. A problem to fix in a future production

- Still plenty of work ahead testing samples

/21

Page 22: 1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.

22

G. Pellegrini

The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors

PSI46 ROCand interconnection

proccess7.9 mm

10.5 mm

52 x 80 pixel unit cells.4160 units150μm x 150μm

(CMS pixel ROC)