1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)...

9
1 | Bruno Hoeft, KIT / AutoKNF - 2013 @ LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) Bruno Hoeft (KIT/SCC) AutoKNF – status June 2013

description

3 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) AutoKNF Production Env. Circuit deployed between DE-KIT -- NDGF – deploy bgp border router of DE-KIT and NORDUnet move to LHC project requirements – no time constraints – every thing within the TCP/IP protocol tolerance – decommission dynamic circuit – BGP instances does not reach each other  timeout (? sec.) – Routing table update neighbor X.X.X.X advertisment-interval XX  default value 30 seconds (eBGP) – ssh session survive outage No outage 0 packet lost – activate dynamic circuit – BGP instances exchanging routing prefix – routing table update

Transcript of 1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)...

Page 1: 1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) Bruno Hoeft (KIT/SCC) AutoKNF – status June 2013.

1 | Bruno Hoeft, KIT / AutoKNF - 2013 @ LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)

Bruno Hoeft (KIT/SCC)

AutoKNF – status June 2013

Page 2: 1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) Bruno Hoeft (KIT/SCC) AutoKNF – status June 2013.

2 | Bruno Hoeft, KIT / AutoKNF - 2013 @ LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)

AutoKNF• AutoBAHN KIT NORDUnet(Ndgf) Fermilab

• Automated Bandwidth Allocation across Heterogeneous Networks the service architecture

– Establish BoD P2P system based circuit in five minutes– Reservation handling as easy as booking an air ticket– Evaluation of dynamic infrastructure• Stable and Robust

• 86,4 terabit in 24h, 86,4 *1012

• extreme low error ratio > 10-14

CRC error 0

input/output error 0

packet drop 0

constant jitter 0

Page 3: 1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) Bruno Hoeft (KIT/SCC) AutoKNF – status June 2013.

3 | Bruno Hoeft, KIT / AutoKNF - 2013 @ LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)

AutoKNF Production Env.

• Circuit deployed between DE-KIT -- NDGF– deploy bgp instance @ border router of DE-KIT and NORDUnet

moveto

• LHC project requirements– no time constraints– every thing within the TCP/IP protocol tolerance

1 2 3 4 5 6 7 8 9 100

10203040

sec.

– decommission dynamic circuit– BGP instances does not reach each other timeout (? sec.)– Routing table update

neighbor X.X.X.X advertisment-interval XX default value 30 seconds (eBGP)

– ssh session survive outage

No outage0 packet lost

– activate dynamic circuit– BGP instances exchanging routing prefix– routing table update

Page 4: 1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) Bruno Hoeft (KIT/SCC) AutoKNF – status June 2013.

4 | Bruno Hoeft, KIT / AutoKNF - 2013 @ LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)

AutoKNF • topology map• dynamic circuit

Page 5: 1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) Bruno Hoeft (KIT/SCC) AutoKNF – status June 2013.

5 | Bruno Hoeft, KIT / AutoKNF - 2013 @ LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)

New Geant BoD layout

Page 6: 1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) Bruno Hoeft (KIT/SCC) AutoKNF – status June 2013.

6 | Bruno Hoeft, KIT / AutoKNF - 2013 @ LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)

gains

previous• rtt = 34.5ms

• BGP restore routing – Everage 32 sec

• BoD circuit establishing ~ 5 min

actual• Shorter fiberpath

rtt = 23 ms• BGP restore routing

– Everage 28 sec• BoD circuit establishing

~ 1.5 min.

Page 7: 1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) Bruno Hoeft (KIT/SCC) AutoKNF – status June 2013.

7 | Bruno Hoeft, KIT / AutoKNF - 2013 @ LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)

P2p BoD -- DE-KIT FNAL• Dynamic circuit can be reserved• AutoBAHN / OSCARS via IDCP• host testbed pools at FNAL/KIT

– Evaluate “stability” of transatlantic dynamic circuit– Error rate

Page 8: 1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) Bruno Hoeft (KIT/SCC) AutoKNF – status June 2013.

8 | Bruno Hoeft, KIT / AutoKNF - 2013 @ LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)

P2p BoD -- DE-KIT FNAL

Further plans:• Connect the two tier-1 sites temporarily• Current 2*1GE “direct” link between DE-KIT and

FNAL– Add the dynamic circuit

• Connect other OSCARS participating us sites to DE-KIT

• Getting part of the “Inder ‘e2e’” testbed

Page 9: 1 | Bruno Hoeft, KIT / AutoKNF - LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT) Bruno Hoeft (KIT/SCC) AutoKNF – status June 2013.

9 | Bruno Hoeft, KIT / AutoKNF - 2013 @ LHC(OPN/ONE), 06/17/13 | Karlruhe Institute of Technology (KIT)

Bruno Hoeft (KIT/SCC)

AutoKNF – status June 2013