06082008161513@Fault_Finder_PCI

download 06082008161513@Fault_Finder_PCI

of 2

Transcript of 06082008161513@Fault_Finder_PCI

  • 7/30/2019 06082008161513@Fault_Finder_PCI

    1/2

    FaultFinder PCIThe Fault Diagnostics System for board repair

    Turn your PC into an effective PCB Fault Finding

    system with FaultFinder PCI

    The workshop diagnostic solution:

    Fully Automatic Guided Probe

    Auto Learn

    Easy to use graphical software

    Built in Libraries with Symbols

    Impendence signature analysis test

    Effective PCB trouble shooting system

    Proven method of finding both digital and analogue faults

  • 7/30/2019 06082008161513@Fault_Finder_PCI

    2/2

    FaultFinder PCI

    Finding faults fast, when nothing else matters, FaultFinder PCI guides you to the exact

    point of failure. Utilising power off test techniques and performing impedance analysis,

    FaultFinder PCI provides a completely safe method of test for newly manufactured

    or in-service boards.

    Featuring Auto Learn, test programs are generated in minutes. Simply select the node

    to be tested and FaultFinder PCI automatically selects the best ranges, from an

    extensive combination, storing the signature for comparison or as part of a test

    program to use in future.

    For even greater fault coverage the FaultFinder Scanner Box increases the number

    of test points that can be tested up to a maximum of 192 nodes. Incorporating an

    extensive built-in library, FaultFinder PCI and FaultFinder Scanner Box make

    programming large boards simple and with minimal effort, letting you concentrateon repairing the board.

    All test programs can be shared between FaultFinder PCI and the FaultFinder

    Portable for maximum flexibility.

    DiagnoSYS Head Office

    DiagnoSYS Limited, Systems House,

    Bedford Road, Hampshire GU32 3QH

    T: +44 (0) 1730 237420 F: +44 (0) 1730 260659

    E: [email protected] W: www.diagnosys.com

    Globalised Support and Sales Offices

    France DiagnoSYS SA, Paris +33 (0) 160 176777

    Germany +49 (0) 896 1524 616

    Sweden +46 (0) 150 101 53

    India DiagnoSYS Electronics Pvt Ltd, New Delhi, Bangalore

    Specification

    2 VI Channels plus CommonPCI card

    Voltage Ranges

    Default Ranges: 1, 5, 10, 15, 20 & 25 Volts

    Voltage ranges are user adjustable in software

    with a resolution of 0.1 Volt

    Frequency Ranges: 5, 15, 25, 50, 150, 300, 750, 1500 & 3000 Hz

    Current Ranges: 16 Resistors selectable across all Voltage and Frequency Ranges.

    Current limited to less than 200 mA peak

    Resistor values: 10R, 20R, 50R, 100R, 200R, 500R, 1K, 2K, 5K, 10K, 20K, 50K,

    100K, 54R, 1K21 & 26K7

    Waveforms: Sine, Square, Triangle & Ramp

    5 Hz to 6 KHz, 0.1 Hz resolution

    0.2 Volt to 25 Volt Peak, 0.1 Volt resolution

    256 Point, 8 bit Comparison architecture

    2 Pulse Channels plus Common

    Pulse mode: Used for Gate fired devices.

    Programmable Mark/Space ratio

    Programmable voltage 5 Volts

    Optional Scanner Unit

    Increases the capacity of FaultFinder PCI from 2 to 96

    or 192 test channels