    FlexiPacket Hub 800

    R2.5

    IDU Accessories Product Description

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    Nokia Siemens Networks is continually str iving to reduce the adverse environmental effects of

    its products and services. We would like to encourage you as our customers and users to join

    us in working towards a cleaner, safer environment. Please recycle product packaging and

    follow the recommendations for power use and proper disposal of our products and their

    components.

    If you should have questions regarding our Environmental Policy or any of the environmental

    services we offer, please contact us at Nokia Siemens Networks for any additional information.

  • 8/10/2019 05 Idu Accessories Product Description

    2/40

    2 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product Description

    The information in this document is subject to change without notice and describes only the

    product defined in the introduction of this documentation. This documentation is intended for the

    use of Nokia Siemens Networks customers only for the purposes of the agreement under whichthe document is submitted, and no part of it may be used, reproduced, modified or transmitted

    in any form or means without the prior written permission of Nokia Siemens Networks. The

    documentation has been prepared to be used by professional and properly trained personnel,

    and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes

    customer comments as part of the process of continuous development and improvement of the

    documentation.

    The information or statements given in this documentation concerning the suitability, capacity,

    or performance of the mentioned hardware or software products are given "as is" and all liability

    arising in connection with such hardware or software products shall be defined conclusively and

    finally in a separate agreement between Nokia Siemens Networks and the customer. However,

    Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions

    contained in the document are adequate and free of material errors and omissions. Nokia

    Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which

    may not be covered by the document.

    Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO

    EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMEN-

    TATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT,

    INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT

    LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS

    OPPORTUNITY OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR

    THE INFORMATION IN IT.

    This documentation and the product it describes are considered protected by copyrights and

    other intellectual property rights according to the applicable laws.

    The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark

    of Nokia Corporation. Siemens is a registered trademark of Siemens AG.

    Other product names mentioned in this document may be trademarks of their respectiveowners, and they are mentioned for identification purposes only.

    Copyright Nokia Siemens Networks 2013. All rights reserved.

    f Important Notice on Product SafetyThis product may present safety risks due to laser, electricity, heat, and other sources

    of danger.

    Only trained and qualified personnel may install, operate, maintain or otherwise handle

    this product and only after having carefully read the safety information applicable to this

    product.

    The safety information is provided in the Safety Information section in the Legal, Safety

    and Environmental Information part of this document or documentation set.

    The same text in German:

    f Wichtiger Hinweis zur ProduktsicherheitVon diesem Produkt knnen Gefahren durch Laser, Elektrizitt, Hitzeentwicklung oder

    andere Gefahrenquellen ausgehen.

    Installation, Betrieb, Wartung und sonstige Handhabung des Produktes darf nur durch

    geschultes und qualifiziertes Personal unter Beachtung der anwendbaren Sicherheits-

    anforderungen erfolgen.

    Die Sicherheitsanforderungen finden Sie unter Sicherheitshinweise im Teil Legal,

    Safety and Environmental Information dieses Dokuments oder dieses Dokumentations-

    satzes.

  • 8/10/2019 05 Idu Accessories Product Description

    3/40

  • 8/10/2019 05 Idu Accessories Product Description

    4/40

    4 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product Description

    6.2 Key characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    7 Dual-IDU accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    7.1 Dual-IDU shroud. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    7.2 Dual-IDU protection panel and optical splitter. . . . . . . . . . . . . . . . . . . . . 36

    7.2.1 Protection panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    7.2.2 Optical splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    7.3 Dual-IDU power injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

    8 FPH800 installation tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

    9 Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

  • 8/10/2019 05 Idu Accessories Product Description

    5/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    5

    IDU Accessories Product Description

    List of FiguresFigure 1 WEEE label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

    Figure 2 CE marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

    Figure 3 MEF certified compliant logo . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

    Figure 4 16-port E1/T1 Multi-Service card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

    Figure 5 4-port GE RJ-45 card. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    Figure 6 4-port GE SFP card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    Figure 7 2-port Power Injector card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Figure 8 2-port FlexBus card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Figure 9 2-port STM-1/4 MSC card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    Figure 10 Electrical SFP module application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

    Figure 11 Optical SFP module application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

    Figure 12 GE electrical interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

    Figure 13 75 ohm Coaxial Cable with MDR68 connectors . . . . . . . . . . . . . . . . . . 24Figure 14 32 pair 120 ohm cable with MDR68 connectors . . . . . . . . . . . . . . . . . . 25

    Figure 15 FB cable application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

    Figure 16 Power supply interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

    Figure 17 Grouding cable assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    Figure 18 RJ45 patch panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    Figure 19 CC4 patch panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Figure 20 BNC patch panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Figure 21 USB key connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    Figure 22 Dual-IDU shroud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    Figure 23 Backplane of the shroud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    Figure 24 A protection panel with 2 optic splitters . . . . . . . . . . . . . . . . . . . . . . . . . 36

    Figure 25 Optic splitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    Figure 26 Power injector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

  • 8/10/2019 05 Idu Accessories Product Description

    6/40

    6 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product Description

    List of TablesTable 1 Structure of this document . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    Table 2 History of changes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

    Table 3 List of symbols and conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

    Table 4 16-port E1/T1 Multi-Service card cabling . . . . . . . . . . . . . . . . . . . . . . . . 13

    Table 5 4-port GE RJ-45 cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    Table 6 4-port SFP card cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

    Table 7 2-port Power Injector card cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Table 8 2-port FlexBus Card cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

    Table 9 2-port STM-1/4 MSC card cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

    Table 10 GE/FE electrical interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

    Table 11 Property of GE copper cable reel with length = 5 m . . . . . . . . . . . . . . . 19

    Table 12 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

    Table 13 Properties for MM fiber patch cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Table 14 Properties for SM fiber patch cord . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

    Table 15 E1/T1 interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    Table 16 Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

    Table 17 FB cable and connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

    Table 18 Power supply interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    Table 19 Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

    Table 20 Color code of power cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

    Table 21 RJ45 patch panel characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

    Table 22 CC4 patch panel characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Table 23 BNC patch panel characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

    Table 24 Mechanical dimension and interface . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

    Table 25 USB key connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    Table 26 Read/Write performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

    Table 27 Environmental specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

    Table 28 Shroud characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

    Table 29 Protection panel characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

    Table 30 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

  • 8/10/2019 05 Idu Accessories Product Description

    7/40

  • 8/10/2019 05 Idu Accessories Product Description

    8/40

    8 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionPreface

    1.4 Symbols and conventions

    The following symbols and mark-up conventions are used in this document:

    Representation Meaning

    fDANGER!

    fWARNING!

    fCAUTION!

    A safety message indicates a dangerous situation where

    personal injury is possible.

    The keywords denote hazard levels with the following meaning:

    DANGER!- Indicates a hazardous situation which, if not

    avoided, will result in death or serious (irreversible) personal

    injury.

    WARNING!- Indicates a hazardous situation which, if not

    avoided, could result in death or serious (irreversible) personal

    injury.

    CAUTION! - Indicates a hazardous situation which, if not

    avoided, may result in minor or moderate (reversible) personal

    injury.

    wNOTICE: A property damage message indicates a hazard that may resultin equipment damage, data loss, traffic interruption, and so on.

    g A note provides important information related to the topic, forexample, not obvious exceptions to a rule or side effects.

    t A tip provides additional information related to the topic which isnot essential in the context, but given for convenience.

    Bold

    All names of graphical user interface (GUI) objects, such aswindows, field names, buttons, and so on.

    Example: Select the Full Screencheck box and press OK.

    Terms and abbreviations which are linked to an entry in the

    glossary and list of abbreviations respectively

    Important key words

    Italic Files, folders, and file system paths.

    Example:/usr/etc/sbin/ftpd.exe

    Emphasized words

    typewriter Input to be typed in a command line or a GUI field.

    Examples:

    ping -t 192.168.0.1

    Enter Worldin the Domainfield.

    Output from a command, error messages, content of a status

    line, and so on

    File content, such as program sources, scripts, logs, and

    settings

    Placeholders, for example as part of a file name or field value.

    Examples:

    .pngor :

    Table 3 List of symbols and conventions

  • 8/10/2019 05 Idu Accessories Product Description

    9/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    9

    IDU Accessories Product Description Preface

    Screenshots of the graphical user interface are examples only to illustrate principles.

    This especially applies to a software version number visible in a screenshot.

    1.5 Waste electrical and electronic equipment (WEEE)

    All waste electrical and electronic products must be disposed of separately from the

    municipal waste stream via designated collection facilities appointed by the government

    or the local authorities. The WEEE label (see Figure 1) is applied to all such devices.

    Figure 1 WEEE label

    The correct disposal and separate collection of waste equipment will help prevent poten-

    tial negative consequences for the environment and human health. It is a precondition

    for reuse and recycling of used electrical and electronic equipment.

    For more detailed information about disposal of such equipment, please contact Nokia

    Siemens Networks.

    The above statements are fully valid only for equipment installed in the countries of the

    European Union and is covered by the directive 2002/96/EC. Countries outside the

    [square brackets] A key to be pressed on a PC keyboard, for example [F11].

    Keys to be pressed simultaneously are concatenated with a +

    sign, for example [CTRL]+[ALT]+[DEL].

    Keys to be pressed one after another are concatenated with

    spaces, for example [ESC] [SPACE] [M].

    > The greater than symbol > is used to concatenate a series of

    GUI items in order to depict a GUI path. This is an abridged pre-

    sentation of a procedure to be carried out in order to perform an

    action or display a window or dialog box.

    Examples:

    A simple menu path: File> Save as ...

    A more complex GUI path:SURPASS TransNetwindow > Toolsmenu >

    3R-Matrix Report command > 3R-Matrix Reportdialog box

    x

    (in card names)

    For convenience, card names are sometimes listed with a lower

    case x variable, in order to concisely represent multiple cards.

    Example:

    I01T40G-x (is to be interpreted as I01T40G-1 and I01T40G-2)

    Representation Meaning

    Table 3 List of symbols and conventions (Cont.)

  • 8/10/2019 05 Idu Accessories Product Description

    10/40

    10 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionPreface

    European Union may have other regulations regarding the disposal of electrical and

    electronic equipment.

    1.6 RoHS complianceFlexiPacket Hub 800 complies with the European Union RoHS Directive 2002/95/EC on

    the restriction of use of certain hazardous substances in electrical and electronic equip-

    ment.

    The directive applies to the use of lead, mercury, cadmium, hexavalent chromium, poly-

    brominated biphenyls (PBB), and polybrominated diphenylethers (PBDE) in electrical

    and electronic equipment put on the market after 1 July 2006.

    Materials usage information on Nokia Siemens Networks Electronic Information

    Products imported or sold in the Peoples Republic of China

    FlexiPacket Hub 800 complies with the Chinese standard SJ/T 11364-2006 on the

    restriction of the use of certain hazardous substances in electrical and electronic equip-ment. The standard applies to the use of lead, mercury, cadmium, hexavalent chro-

    mium, polybrominated biphenyls (PBB), and polybrominated diphenyl ethers (PBDE) in

    electrical and electronic equipment put on the market after 1 March 2007.

    1.7 CE compliance

    FlexiPacket Hub 800 is in compliance with the essential requirements and other relevant

    provisions of Directive: 2006/95/EC, 2004/108/EC, and 1999/5/EC.

    Figure 2 CE marking

    1.8 MEF compliance

    FlexiPacket Hub 800 operating at the NNI delivers EPL, EVPL and E-LAN service

    complies with the Metro Ethernet Forum MEF14 technical specification. FlexiPacket

    Hub 800 operating at the UNI delivers EPL, EVPL and E-LAN service complies with the

    Metro Ethernet Forum MEF9 technical specification.

    The product is marked with the CE marking

  • 8/10/2019 05 Idu Accessories Product Description

    11/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    11

    IDU Accessories Product Description Preface

    Figure 3 MEF certified compliant logo

  • 8/10/2019 05 Idu Accessories Product Description

    12/40

    12 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionOverview

    2 OverviewThe main accessories of FPH800 includes the following.

    gAll accessories must be ordered separately. They are not in the default delivery ofFPH800.

    2.1 FPH800 plug-in cards

    FPH800 supports plug-in cards for carrying traffic coming from the co-located equip-

    ment.

    2.2 FPH800 connection accessaries

    FPH800 can be connected to local traffic through the following types of accessories.

    Cables and connectors for Ethernet copper interfaces.

    Cables for Ethernet optical interfaces.

    Cables for STM-1 optical interfaces.

    Cables for E1 interfaces.

    Cables and connectors for FB interfaces.

    SFP modules are designed to support ATM, SDH, SONET, GE and Fiber Channel com-

    munication standards.

    2.3 FPH800 patch panels

    Patch panel is used if the local equipment does not support MDR68 connector in E1/T1

    traffic transmit. Patch panel works as a switcher between FPH800 mainboard and the

    local equipment, which switches the signals from MDR68 connector to RJ45 connec-

    tors, CC4 connectors or BNC connectors.

    2.4 FPH800 dual-IDU accessaries

    To support dual-IDU mode for FPH800s, some dedicated accessories have been intro-

    duced (e.g., shroud, protection panel and optical splitter modules).

    2.5 FPH800 USB key

    FPH800 is equipped with a USB key for the backup of IDU configuration. It provides a

    socket to host a 1 Gigabit USB key type. And the USB key is used for IDU/ODU config-

    uration and software load backup. The USB key is pre-formatted of FAT mode in factory.

    In case of Dual-IDU protected configuration, only one USB key is used, located in the

    Main IDU.

    2.6 FPH800 installation tools

    The installation tool includes: Mounting bracket, ETSI N3 rack, 19-inch rack and rack

    screws, nuts, etc.

  • 8/10/2019 05 Idu Accessories Product Description

    13/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    13

    IDU Accessories Product Description FPH800 plug-in cards

    3 FPH800 plug-in cardsFPH800 supports plug-in cards for carrying traffic coming from the co-located equip-

    ment. The external cards can be placed in slot 1 and slot 2 on the FPH800 mainboard.

    16-port E1/T1 Multi-Service Card

    4-port GE RJ-45 Card

    4-port SFP Card

    2-port Power Injector Card

    2-port FlexBus card

    2-port STM-1/4 MSC Card

    3.1 16-port E1/T1 Multi-Service card

    16-port E1/T1 Multi-Service card is the PIU (Plug-in Unit) of the FPH800.

    Figure 4 16-port E1/T1 Multi-Service card

    3.2 4-port GE RJ-45 card

    4-port GE RJ-45 card is the PIU of the FPH800, it provides extended 4 GE interfaces

    based on 1000Base-T standard. If the GE interface is used as ODU interface, extra 2-

    port Power Injector cardis needed.

    Parameter Description

    Interface 16 channels of E1/T1 interfaces

    Cable type 32 pair 75 ohm impedance coaxial cable;

    or 32 pair 120 ohm impedance coaxial

    cable

    Connector MDR68

    Table 4 16-port E1/T1 Multi-Service card cabling

  • 8/10/2019 05 Idu Accessories Product Description

    14/40

    14 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionFPH800 plug-in cards

    Figure 5 4-port GE RJ-45 card

    3.3 4-port GE SFP card

    4-port GE SFP card is the PIU of the FPH800, it provides extended 4 GE optical inter-

    faces.

    Figure 6 4-port GE SFP card

    3.4 2-port Power Injector card

    2-port Power Injector card supports 2 GE interfaces power feeding (1000Base-T).

    Parameter Description

    Interface 4 10/100/1000BaseT electrical inter-

    facesCable type CAT6 S/FTP

    Connector Shielded RJ-45

    Table 5 4-port GE RJ-45 cabling

    Parameter Description

    Cable type single/multi mode fiber duplex

    Connector type LC-LC duplex

    Table 6 4-port SFP card cabling

  • 8/10/2019 05 Idu Accessories Product Description

    15/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    15

    IDU Accessories Product Description FPH800 plug-in cards

    Figure 7 2-port Power Injector card

    3.5 2-port FlexBus card

    2-port FlexBus card supports local FlexBus interfaces.

    Figure 8 2-port FlexBus card

    Parameter Ethernet ODU

    Interface 2

    10/100/1000BaseTEthernet electrical

    interfaces & 2 ODU

    interfaces

    -

    Cable type CAT6 S/FTP Double shielded, four twisted pairs, Cat-

    5e cable compliant (for outdoor condition).

    Each pin manages at least 24 AWG wire

    diameter.

    Connector type Shielded RJ45 Shielded RJ45 (towarding the power

    injector card); amphenol (towarding the

    Flexi-Packet Multi Radio)

    Table 7 2-port Power Injector card cabling

    Parameter Description

    Interface 2 FB optical interfaces

    Table 8 2-port FlexBus Card cabling

  • 8/10/2019 05 Idu Accessories Product Description

    16/40

    16 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionFPH800 plug-in cards

    3.6 2-port STM-1/4 MSC card

    2-port STM-1/4 MSC card provides 2 X STM-1 or 2 X STM-4 interfaces. When the user

    change the interface between STM-1 and STM-4, all services related to the interface

    must be shut down.

    The main functions of this card include MSP 1 + 1, EoS (Ethernet over GFP over SDH)

    and Virtual concatenation (VC-4, VC-12).

    Figure 9 2-port STM-1/4 MSC card

    Cable type Coaxial cable, double shielded, or semi-

    rigid

    Connector FlexBus TNC

    Parameter Description

    Table 8 2-port FlexBus Card cabling (Cont.)

    Parameter Description

    Interface 2 STM-1 optical interfaces with SFP

    module or 2 STM-4 optical interfaces

    with SFP modules

    Cable type Multi-mode fiber patch cord or single-

    mode fiber patch cord

    Connector type LC-LC

    Table 9 2-port STM-1/4 MSC card cabling

  • 8/10/2019 05 Idu Accessories Product Description

    17/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    17

    IDU Accessories Product Description FPH800 connection accessories

    4 FPH800 connection accessoriesThis chapter provides an introduction and overview of the connectors and cables used

    in FPH800 local connection. Most of the interfaces are located on the front panel. Only

    the grounding point is on the lateral side of FPH800.

    g For details on cables and connectors connecting ODU interfaces, refer to ODUmanuals.

    Before the introduction of cables, SFP (small form-factor pluggable) modules is to be

    introduced.

    4.1 SFP transceiver

    SFP interface

    There are 2 SFP interfaces on the front panel of FPH800 which can be configured to

    Ethrenet port or STM-1 port by software. SFP interface is designed to support SDH and

    GE communication standards.

    SFP transceiver

    SFP transceiver, or SFP module, is a compact, hot-pluggable transceiver used for com-

    munication applications. It is specified by a multi-source agreement (MSA). It interfaces

    FPH800 mainboard to a fiber optic or copper networking cable.

    SFP transceivers are available with a variety of types, allowing users to select the appro-

    priate transceiver for each link to provide required electrical or optical reach over the

    available cable types. This solution gives interface flexibility for FPH800.

    g For all the types and order codes of SFP modules, refer toIDU and Accessories OrderCodes Reference.

    4.1.1 SFP transceiver for electrical interfaces

    Electrical SFP is compliant with 10BASE-T/100Base-TX/1000 Base-T interfaces. It does

    not support synchronous Ethernet.

    Figure 10 Electrical SFP module application

    RJ45Connector

    4PairsCable

    Electrical SFP Module

  • 8/10/2019 05 Idu Accessories Product Description

    18/40

    18 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionFPH800 connection accessories

    4.1.2 SFP transceiver for optical interfaces

    Optical SFP is compliant with 1000 Base-X, synchronous Ethernet and STM-1 inter-

    faces. Multi-mode fiber and single-mode fiber are supported through different types of

    SFP optical transceivers.

    Figure 11 Optical SFP module application

    4.2 Cables and connectors for Ethernet copper interfaces

    Figure 12 GE electrical interfaces

    FE/GE electrical interfaces

    The cables and connectors in this section are used to connect Ethernet copper inter-faces on the front panel, such as

    4 X 10/100/1000 Base-T ports.

    DCN port.

    LC

    Optical Patch-Cord

    Optical SFP module

    Item Description

    Interface type 10/100/1000 Base-T

    Duplex mode Half and full

    Rate 10/100/1000 Mbit/s

    Table 10 GE/FE electrical interfaces

    RJ45 Shielded Connector

    4 Pairs Shielded Cable

    ElectricalSFP Module

  • 8/10/2019 05 Idu Accessories Product Description

    19/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    19

    IDU Accessories Product Description FPH800 connection accessories

    RJ45 connector

    RJ45 is a registered jack standard for a modular connector using 8 conductors, which

    specifies the physical male and female connectors as well as the pin assignments of the

    wires in a cable. The physical dimensions of the connectors are specified in ANSI/TIA-

    1096-A and ISO-8877 standards.

    Cat6 cable

    Category 6 cable, commonly referred to Cat6, is a cable standard for Gigabit Ethernet

    and other network physical layers that is backward compatible with Cat5/5e and Cat3

    cable standard. Compared with Cat5 and Cat5e, Cat6 features more stringent specifi-

    cations for crosstalk and system noise. The cable standard provides performance of up

    to 250 MHz and is suitable for 10BASE-T, 100BASE-TX (Fast Ethernet), 1000BASE-T/1000BASE-TX (Gigabit Ethernet) and 10GBASE-T (10-Gigabit Ethernet).

    Table 11is the property of GE copper cable with length = 5m. And users can also make

    Ethernet copper cords with cables and connectors with the given order codes in brakets

    for other length.

    MDI type auto sensing MDI/MDIX

    Front panel reference 10/100/1000 Base-T, DCN

    Connector type Shielded GE RJ45 eight-pin gold plated finishing

    Cable 4 pairs STP cat6

    Power Supply -48 Volt P + E functionality is supported in interfaces 3

    and 4. A label (Pwr) indicates the presence of the ODU

    power supply.

    Property Description

    Order code CS73199.05

    Connector 1 RJ45 (T555ETRJ.08)

    Connector 2 RJ45 (T555ETRJ.08)

    Cable Ethernet STP Cat6 cable (T555ECR5.00)

    Length 5 m

    Table 11 Property of GE copper cable reel with length = 5 m

    Connector 1 Pair Color Connector 2

    1 pair A + white/orange 1

    2 pair A - orange 2

    Table 12 Wiring

    Item Description

    Table 10 GE/FE electrical interfaces (Cont.)

  • 8/10/2019 05 Idu Accessories Product Description

    20/40

    20 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionFPH800 connection accessories

    4.3 Cables for Ethernet optical interfaces

    Multimode/singlemode optical cables are used to connect FPH800 optical GE interfaceover SFP optical modules with local traffic. The application of optical fiber is seen in

    Figure 11.

    For description on SFP interface and SFP module, refer to Section SFP transceiver for

    optical interfaces.

    GE optical interface

    Gigabit Ethernet (GE) has the speed to 1000 Mbit/s.

    LC connector

    LC (Lucent Connector) connector is the most common type of connector. It terminates

    the end of an optical fiber, and enables quicker connection and disconnection than splic-

    ing. The connectors mechanically couple and align the cores of fibers so that light can

    pass.

    MM optical fiber

    Multi-mode (MM) optical fiber is a type of optical fiber mostly used for communication

    over short distances. Typical MM links have data rates of 10 Mbit/s to 10 Gbit/s over link

    lengths of up to 600 m (300 m for 10 Gbit/s).

    g For all the types and order codes of MM fiber patch cords, refer toIDU and AccessoriesOrder Codes Reference.

    3 pair B + white/green 3

    4 pair C + blue 4

    5 pair C - white/blue 5

    6 pair B - green 6

    7 pair D + white/brown 7

    8 pair D - brown 8

    Connector 1 Pair Color Connector 2

    Table 12 Wiring (Cont.)

    Property Description

    Cable type break-out cable 2 X 2.0 mm LSZH

    Connector LC-LC

    Fiber type multi-mode 50/125 um

    Fanout leg length 195 +/- 5 mm

    Table 13 Properties for MM fiber patch cord

  • 8/10/2019 05 Idu Accessories Product Description

    21/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    21

    IDU Accessories Product Description FPH800 connection accessories

    SM optical fiber

    Single-mode (SM) optical fiber is better at retaining the fidelity of each light pulse over

    longer distances than MM fiber. SM fiber can have a higher bandwidth than MM fiber.

    g For all the types and order codes of SM fiber patch cords, refer toIDU and AccessoriesOrder Codes Reference.

    4.4 Cables for STM-1 optical interfaces

    Single-mode optical cables are used to connect FPH800 optical STM-1 interface over

    SFP optical modules with local traffic. The application of optical fiber is seen in Figure

    11.

    For description on SFP interface and SFP module, refer to Section SFP transceiver for

    optical interfaces.

    STM-1 interface

    The STM-1 (Synchronous Transport Module level-1) is the SDH ITU-T fiber optic

    network transmission standard. It has a rate of 155.52 Mbit/s.

    g For all the types and order codes of SM fiber patch cords, refer toIDU and AccessoriesOrder Codes Reference.

    Insertion loss maximum 0.50 dB @ 1300 nm

    Operating temperature - 25 OC ~ + 70 OC

    The insertion loss test acc. to IEC 61300-3-4

    Property Description

    Table 13 Properties for MM fiber patch cord (Cont.)

    Property Description

    Cable type break-out cable 2 X 2.0 mm, Riser

    Connector LC-LC

    Fiber type single-mode 9/125 um

    Fanout leg length 300 -50/+ 10 mm

    Insertion loss maximum 0.50 dB @ 1550 nm

    Return loss minimum 46 dB @ 1550 nm

    Operating temperature - 25 OC ~ + 70 OC

    The insertion loss test acc. to IEC 61300-3-4

    The return loss test acc. to IEC 61300-3-6

    Table 14 Properties for SM fiber patch cord

  • 8/10/2019 05 Idu Accessories Product Description

    22/40

    22 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionFPH800 connection accessories

    For properties of SM fiber patch cord, refer to SM optical fiber.

    4.5 Cables for E1 interfaces

    E1 interface

    An E1 link operates over two separate sets of wires, usually twisted pair calbe. The line

    data rate is 2.048 Mbit/s which is split into 32 timeslots each being allocated 8 bits in

    turn.

    The E1/T1 interfaces are used only as local interfaces. There are 16 X E1/T1 interfaces

    with 75 ohm and 120 ohm impedance.

    The following table descripes the pin definition of the E1/T1 interface.

    Item Description

    Interface Type E1/T1 short haul

    Front panel reference 16 X E1/T1Interface rate E1/T1 Software selectable

    Connector type MDR68 connector

    Table 15 E1/T1 interfaces

    Pin

    number

    Pin function Direction Pin

    number

    Pin function Direction

    1 TXTIP1 output 35 RXTIP1 input

    2 TXRING1 output 36 RXRING1 input

    3 TXTIP2 output 37 RXTIP2 input

    4 TXRING2 output 38 RXRING2 input

    5 TXTIP3 output 39 RXTIP3 input

    6 TXRING3 output 40 RXRING3 input

    7 TXTIP4 output 41 RXTIP4 input

    8 TXRING4 output 42 RXRING4 input

    9 TXTIP5 output 43 RXTIP5 input

    10 TXRING5 output 44 RXRING5 input

    11 TXTIP6 output 45 RXTIP6 input

    12 TXRING6 output 46 RXRING6 input

    13 TXTIP7 output 47 RXTIP7 input

    14 TXRING7 output 48 RXRING7 input

    15 TXTIP8 output 49 RXTIP8 input

    16 TXRING8 output 50 RXRING8 input

    17 GND - 51 GND -

    Table 16 Pinout

  • 8/10/2019 05 Idu Accessories Product Description

    23/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    23

    IDU Accessories Product Description FPH800 connection accessories

    Pin 17, 34, 51 and 68 are required to be connected to Ground. DC isolation is possible

    as an external option by not connecting the cable shield to the connector shield. The

    RING pin of transmit and receive need connect to GND through the external cable when

    supporting the unbalanced 75 ohm coaxial cable.

    Coaxial cable

    Coaxial cable, or coax, has an inner conductor surrounded by a flexible, tubular insulat-

    ing layer, surrounded by a tubular conducting shield.

    Coaxial cable is used as a transmission line for radio frequency signals. One advantageof coax over other types of radio transmission line is that in an ideal coaxial cable the

    electromagnetic field carrying the signal exists only in the space between the inner and

    outer conductors. This allows coaxial cable runs to be installed next to metal objects

    such as gutters without the power losses that occur in other types of transmission lines.

    Coaxial cable also provides protection of the signal from external electromagnetic inter-

    ference.

    g For all the types and order codes of E1 cables, refer toIDU and Accessories OrderCodes Reference.

    18 TXTIP9 output 52 RXTIP9 input

    19 TXRING9 output 53 RXRING9 input

    20 TXTIP10 output 54 RXTIP10 input

    21 TXRING10 output 55 RXRING10 input

    22 TXTIP11 output 56 RXTIP11 input

    23 TXRING11 output 57 RXRING11 input

    24 TXTIP12 output 58 RXTIP12 input

    25 TXRING12 output 59 RXRING12 input

    26 TXTIP13 output 60 RXTIP13 input

    27 TXRING13 output 61 RXRING13 input

    28 TXTIP14 output 62 RXTIP14 input

    29 TXRING14 output 63 RXRING14 input

    30 TXTIP15 output 64 RXTIP15 input

    31 TXRING15 output 65 RXRING15 input

    32 TXTIP16 output 66 RXTIP16 input

    33 TXRING16 output 67 RXRING16 input

    34 GND - 68 GND -

    Pin

    number

    Pin function Direction Pin

    number

    Pin function Direction

    Table 16 Pinout (Cont.)

  • 8/10/2019 05 Idu Accessories Product Description

    24/40

    24 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionFPH800 connection accessories

    4.5.1 75 ohm coaxial cable

    Figure 13 75 ohm Coaxial Cable with MDR68 connectors

    Construction

    Conductor: 30 AWG solid bare copper wire

    Insulation: Foam PE, diameter = 1.1 mm

    Inner braiding: 0.08 mm bare copper wire, Min. 95% coverage

    Inner jacket: LSZH, gray, diameter = 1.8 mm, identified with number

    Outer braiding: 0.10 mm bare copper wire, Min. 40% coverage

    Outer jacket: LSZH, black, diameter = 14.0 mm

    Braid construction: E1 patch cord 75 ohm MDR68-MDR68 cable assembly 60 exit, 32

    core coaxial cable

    Electrical characteristics

    Conductor DC resistance: < 365 ohm/Km at 20C

    Impedance: 75 5 ohm at 1 MHz

    Return loss: 3.3 dB/100 m at 1 MHz to 10 MHz

    Attenuation: 3.3 dB/100 m at 1 MHz; 9.5 dB/100 m at 10 MHz

    Assembly rating

    Voltage rating: 30 V AC

    Current rating: 0.5 A/Pin

    Temperature rating: -40C to + 85C

    Pin 1Pin 34

    Pin 68 Pin 35

    75ohm Coaxial Cable

    MDR Plug Connector

    MDR68 Shell

    Termination Cable

    Cable Joint

    Pin 1

    Pin 1Pin 35Pin 68

    Pin 34

    Pin 34

    Pin 68Pin 35

  • 8/10/2019 05 Idu Accessories Product Description

    25/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    25

    IDU Accessories Product Description FPH800 connection accessories

    Insulation resistance: 100 M

    Withstanding Voltage: 300 V AC

    4.5.2 120 ohm coaxial cable

    Figure 14 32 pair 120 ohm cable with MDR68 connectors

    Construction

    Conductor: Diameter 0.40 mm solid bare copper wire

    Insulation: Foam PE, diameter = 0.82 mm

    Drain Wire: 0.40 mm solid copper wire

    Cabling: PET tape

    AL/PET tape: Diameter 0.40 mm tined copper drain wire

    Braiding: 0.12 mm bare copper wire, Min. 85% coverage

    Jacket: LSZH, black, Max. diameter = 12.0 mm

    Braid construction: E1 patch cord 120 ohm MDR68-MDR68 cable assembly 60 exit, 32

    twisted pair shielded round cable

    Electrical characteristics

    Characteristic impedance: 120 5 ohm at 1 MHz

    Twisted pair: Max. -53.0 dB/100 m at 1 MHz

    Attenuation: Max. 2.8 dB/100 m at 1 MHz

    Assembly rating

    Pin 1Pin 34

    Pin 68 Pin 35

    32pair Shielded RoundCable

    MDR Metal Junction Shell

    MDR Connector

    Pin 68

    Pin 68

    Pin 35

    Pin 34

    Pin 34

    Pin 35Pin 1

    Pin 1

  • 8/10/2019 05 Idu Accessories Product Description

    26/40

    26 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionFPH800 connection accessories

    Voltage rating: 30 V AC

    Current rating: 0.5 A/Pin

    Temperature rating: -40C ~+ 85C

    Insulation resistance: 100 M

    Withstanding Voltage: 300 V AC

    4.6 Cables and connectors for FlexBus interfaces

    Figure 15 FB cable applicationFB interface

    The FlexBus (FB) interface is designed to support legacy product interface from Nokia.

    The FB interface only operate in local interface mode. It only transfers data between two

    indoor units.

    TNC connector

    The TNC (threaded Neill-Concelman) connector is a threaded version of the BNC con-

    nector. The connector has a 50 ohm impedance (75 ohm is also available). It has better

    performance than the BNC connector at microwave frequencies.

    For description on coaxial cable, refer to Coaxial cable.

    Users can assemble FB cable with the cable and connector with the order codes given

    below. Note that the two TNC connectors are alternative.

    Order code Item

    T55256.02 FB cable reel, 500 m

    T55255.07 IDU/ODU TNC connector, male

    Table 17 FB cable and connector

    FLEXBUS CABLE

    T55256.02

    FLEXBUS CABLE

    T55256.02

    TNC CONNECTOR (MALE)

    T55255.07

    TNC CONNECTOR (MALE ANGLE)

    T55255.08

  • 8/10/2019 05 Idu Accessories Product Description

    27/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    27

    IDU Accessories Product Description FPH800 connection accessories

    The cable interface uses +5 V and +3.3 V power supply for operation. The consumption

    of the cable interface alone is around 200 mA and 80 mA for +5 V and +3.3 V respec-

    tively.

    4.7 D.C Power interface

    FPH800 provides protection of power supply interface. If one power supply failed,

    FPH800 can switch to the other. A power cable is an assembly of two electrical conduc-

    tors, held together with an overall sheath. This interface carries the -48 Volt DC power

    supply.

    Figure 16 Power supply interface

    T55255.08 IDU/ODU TNC connector, male angle

    Order code Item

    Table 17 FB cable and connector (Cont.)

    Phoenix 4-Pin Connector

    2 X 1.5 mm cable

    Plastic Hook

    (Lower Enclosure)

    Plastic Hook

    (Upper Enclosure)

  • 8/10/2019 05 Idu Accessories Product Description

    28/40

    28 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionFPH800 connection accessories

    g A 12 A fuse is used in power channel.

    Construction

    Conductor: Standard tinned copper wire

    Construction: 30 / 0.25 mm

    Insulation: HD-PE

    Nominal thickness: 0.7 mm

    Minimum thickness: 0.53 mm

    Nominal diameter: 3.00 0.10 mm

    Filler

    Braiding: 0.12 mm tinned copper wire

    Coverage: 85%

    Jacket: LSZH

    Color: Optional

    Nominal thickness: 0.74 mm

    Minimum thickness: 0.60 mm

    Nominal diameter: 8.00 0.20 mm

    Interface type Floating -48 Volt DC

    Voltage range -40.5 VDC to -57.6 VDC

    When operating without ODU power supply the

    system shall be able to operate in the extended

    voltage range -38.4 VDC to -57.6 VDC.

    Reference Indoor Unit / Variant 1, with the following exceptions:

    the input voltage is floating

    Front panel reference PWR A and PWR B

    Connector type Phoenix 4 Pin connector, 12A.

    Fastening by screw required.

    Connector shell 4-Pole straight strain snap

    Antistatic plastic bag BAG ESD 80x120 pink, zip lock

    Maximum current 10 A

    Table 18 Power supply interfaces

    Pin number Pin function

    1 PWR A +

    2 PWR B +

    3 PWR B -

    4 PWR A -

    Table 19 Pinout

  • 8/10/2019 05 Idu Accessories Product Description

    29/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    29

    IDU Accessories Product Description FPH800 connection accessories

    Electrical characteristics

    Conductor DC resistance: 15 /Km

    Insulation resistance: 100 M/Km

    Dielectric strength: AC 2000 V/ 1Min

    Machenical characteristics

    Working temperature: -40C ~ +80C

    Color code

    4.8 Grounding cable

    The grounding cable is 10 AWG UL cable which meets ROHS requirement.

    Figure 17 Grouding cable assembly

    Construction

    Conductor: 104/ 0.254 mm stranded tinned copper wire

    Nom diameter: 3.43 mm

    Insulation: PVC

    Color: Yellow/Green

    Nom thickness: 0.76 mm

    Min thickness: 0.69 mm

    Diameter: 5.07 0.08 mm

    Electrical characteristics Conductor DC resistance at 20C: 3.90 /Km

    Sparkal test: 10000 V

    Voltage rating: 600 V

    Flame characteristics

    Fire resistance: VW-1 and FT1, pass

    Core Color Core Color

    1 Black 2 Red

    Table 20 Color code of power cable

  • 8/10/2019 05 Idu Accessories Product Description

    30/40

    30 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionFPH800 patch panels

    5 FPH800 patch panelsThere are three types of patch panels applicable to FPH800, which are RJ45 patch

    panel, CC4 patch panel, and BNC patch panel. The patch panels are the switching

    equipments allowing the incoming signals from 16XE1/T1 interface MDR68 connector

    to be output from 16XRJ45 connector, 32XCC4 connector or 32XBNC connector. If the

    users equipment connecting to the FPH800 16XE1/T1 interface does not have the inlet

    for MDR68 connector, one patch panel can be used to switch the signals to fit the con-

    nector which can be carried by the equipment.

    5.1 RJ45 patch panel

    RJ45 patch panel is used to switch the signals input from MDR68 connector to be output

    from 16XRJ45 connectors.

    Figure 18 RJ45 patch panel

    5.2 CC4 patch panel

    CC4 patch panel is used to switch the signals input from MDR68 connector to be output

    from 32XCC4 connectors.

    Parameter Description

    Height 22 mm

    Width 440.6 mm

    Depth 69.976 mm

    Operating temperature -5C ~ +55C

    Table 21 RJ45 patch panel characteristics

    Pin 1Pin 34

    Pin 68 Pin 35Pin 1

  • 8/10/2019 05 Idu Accessories Product Description

    31/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    31

    IDU Accessories Product Description FPH800 patch panels

    Figure 19 CC4 patch panel

    5.3 BNC patch panel

    BNC patch panel is used to switch the signals input from MDR68 connector to be output

    from 32XBNC connectors.

    Figure 20 BNC patch panel

    Parameter Description

    Height 22 mm

    Width 440.6 mm

    Depth 81 mm

    Operating temperature -5C ~ +55C

    Table 22 CC4 patch panel characteristics

    Pin 1Pin 34

    Pin 68 Pin 35

    Out In

    Parameter Description

    Height 44 mm

    Width 440.6 mm

    Depth 54.1 mm

    Operating temperature -5C ~ +55C

    Table 23 BNC patch panel characteristics

    Pin 1Pin 34

    Pin 68 Pin 35

    Out

    In

  • 8/10/2019 05 Idu Accessories Product Description

    32/40

    32 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionFPH800 USB key

    6 FPH800 USB key

    6.1 Physical information

    g For the detailed codes and descriptions, please refer to FlexiPacket Hub 800 IDU Rel.2.5 Order Codes Reference manual.

    The USB key is used for IDU/ODU configuration and software load backup. 1 GigaByte

    Serial Data Flash memory is suitable for in-system reprogramming using Serial Periph-

    eral Interface (SPI).

    The USB key interface is not a real external interface because it does not enable any

    interconnection of digital network components but it gives the external access of the

    USB key unit that is a proper component of the equipment.

    The USB key interface deals with a Serial Peripheral Interface (SPI) system that

    consists of one master device and one slave device. Exactly, in the USB key interface,

    the master is defined as the processor of the system controller unit providing the SPI

    clock and the slave selection command. While the slave works as any non-volatile

    memory device suitable for in-system reprogramming.

    Figure 21 USB key connection

    Mechanical demension and interface

    Parameter ESD-rated enclosure

    Length with cap 66.1 mm (2.602 in) MaxWidth 16.60 0.20 mm (0.654 0.008 in)

    Height 7.02 0.20 mm (0.276 0.008 in)

    Interface type/Front

    panel reference

    USB

    Table 24 Mechanical dimension and interface

    USB key

  • 8/10/2019 05 Idu Accessories Product Description

    33/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    33

    IDU Accessories Product Description FPH800 USB key

    6.2 Key characteristics

    It is possible to insert the USB key under the powered appliance. And the replacement

    key must not produce any temporary interruption of service. The insertion into the equip-ment connector is detected through the presence line toward the system controller with

    the ground level.

    The 3.3 V power source must be supplied to the interface throughout a protection fuse

    to ensure the integrity of SPI. But it is needed to be aware of the environmental hazards

    such as accidental short circuits possible at the interface, connector pins that are touch-

    able throughout the front panel cut-out when the USB key is not inserted.

    If the system controller need to RESET, the working USB key must be terminated and

    the IDLE status should be set. After RESET condition is cleared, all the operation will be

    resumed back to normal.

    Performance

    The Industrial Grade UFD is USB 2.0 high-speed (480 Mb/sec) and USB 1.1 full-speed

    (12 Mb/sec) compliant.

    LED functionality

    The Industrial Grade UFD with standard enclosure incorporates a LED activity indicator

    that functions as described below:

    LED flashing: Industrial Grade UFD is transmitting/receiving data or is identification

    process.

    Default LED colors: Blue.

    Environmental specifications

    Appliance Connector type Notes

    Device connector 8 contacts Double socket

    straight through hole 2mmgrid

    The connector is part of

    USB key unit

    Card connector 8 contacts right angle pin

    header through hole 2mm

    grid

    Equipment access

    Table 25 USB key connectors

    Parameter Value

    Sustained read up to 30 MB/sec

    Sustained write up to 20 MB/sec

    Table 26 Read/Write performance

  • 8/10/2019 05 Idu Accessories Product Description

    34/40

  • 8/10/2019 05 Idu Accessories Product Description

    35/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    35

    IDU Accessories Product Description Dual-IDU accessories

    7 Dual-IDU accessories

    7.1 Dual-IDU shroud

    Figure 22 Dual-IDU shroud

    Figure 23 Backplane of the shroud

    FPH800 shroud is designed for dual-IDU site configuration. 2 IDUs can be plugged into

    the shroud. 2 guide pins are added at the backplane of the shroud for easy plug and 2

    guide holes are added on FPH800 rear side to match this backplane.

    With the backplane of the shroud, 2 FPH800 can work in active/standby.

    g For details on dual-IDU site configuration and FPH800 rear side interfaces, refer to IDUProduct description.

    BACKPLANE GUIDE PIN

    GND

    Parameter Description

    Height 2 U

    Width 450 mm

    Depth 256 mm

    Table 28 Shroud characteristics

  • 8/10/2019 05 Idu Accessories Product Description

    36/40

    36 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionDual-IDU accessories

    7.2 Dual-IDU protection panel and optical splitter

    7.2.1 Protection panel

    Figure 24 A protection panel with 2 optic splitters

    The protection panel is used for local traffic in dual-IDU mode. Its user interface is con-

    nected with local equipment, while its 2 IDU interfaces connected with 2 IDUs respec-

    tively. Only one of the IDUs is working in active mode. The other IDU is used for traffic

    protection.

    The application above applies to

    8 pairs of GE electrical interface

    2 pairs of GE optical interface

    1 pair of 16 X E1/T1 interface

    gFor details on dual-IDU site configuration, refer to IDU Product Description.

    7.2.2 Optical splitter

    Figure 25 Optic splitter

    The optic splitter is a plug-in unit of the dual-IDU protection panel. It must be ordered

    separately from the protection panel. One protection panel fits 2 optic splitters at most.

    Pin 1Pin 34

    Pin 68 Pin 35Pin 1

    OPTIC SPLITTER

    Parameter Description

    Height 1 U

    Width 440 mm without brackets

    Depth 150 mm

    Table 29 Protection panel characteristics

    OPTICAL INTERFACE

  • 8/10/2019 05 Idu Accessories Product Description

    37/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    37

    IDU Accessories Product Description Dual-IDU accessories

    When no optic splitter is installed, a blank panel should be installed in the place of the

    splitter.

    There are 2 kinds of optic splitters with the same look. One is for multi-mode (MM) fiber

    connection and the other is for single-mode (SM) fiber connection. Users can tell fromthe label on the faceplate of the splitter.

    7.3 Dual-IDU power injector

    Power injector a 1-U-height box, which is used to support dual-IDU protection while 1 +

    0 ODU is connected to the IDU. It realizes two funtions: one is to inject power for GE

    port to ODU, another is to do GE splitter as the command from IDU via control port on

    dual-IDU power injector. With this GE splitter function, GE impedence can be match and

    the cable to ODU can be longer. The target is to reach 50 m.

    IDU alarm interface is connected with dual-IDU Power injector port to control which IDU

    is connected with ODU. These IDUs work in active/standby mode. In normal condition,ODU is connected with Master IDU via Power injector. If Master IDU is down, the Slave

    one will be active and send out command to dual-IDU Power injector to switch. Dual-IDU

    Power injector implements the switch as this command. In this case, one IDU failure will

    not result in traffic down to ODU.

    The supported GE interface number can be 4 for each dual-IDU Power injector, and 8

    GE ports if cascaded dual-IDU Power injector is used.

    A grounding connector is on the lateral side of the Power injector. It must be connected

    to the grounding point on the rack.

    Figure 26 Power injector

    g Two dual-IDU Power Injectors support cascading for extensive ODU connection. The forthe connection application, please refer toIDU Product Descriptionmanual. In the cas-

    cading connection, the cascaded cable is not provided by NSN. Please follow the pin

    defination in Table 30to make the cascaded cable with GE cable and RJ45 connectors.

    RJ-45 for Cascade

    RJ-45 for Alarm from Dual-IDU

    GE Electrical with Dual-IDU GE Electrical with ODUs

    RJ-45 for External Alarm Power Connector

    Connector 1 Pair Color Connector 2

    1 pair A + white/orange 1

    2 pair A - orange 2

    3 pair B + white/green 7

    4 pair C + blue 4

    5 pair C - white/blue 5

    Table 30 Wiring

  • 8/10/2019 05 Idu Accessories Product Description

    38/40

    38 A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    IDU Accessories Product DescriptionDual-IDU accessories

    6 pair B - green 6

    7 pair D + white/brown 3

    8 pair D - brown 8

    Connector 1 Pair Color Connector 2

    Table 30 Wiring (Cont.)

  • 8/10/2019 05 Idu Accessories Product Description

    39/40

    A25000-A0800-E028-01-76P1

    Issue: 1 Issue date: May 2013

    39

    IDU Accessories Product Description FPH800 installation tools

    8 FPH800 installation tools

    g For the detailed codes, please refer to IDU and Accessories Order Codes Reference.For the detailed description, refer to IDU HW Install.

    FPH800 mounting kits includes the following.

    FPH800 dual-IDU shroud 21 mounting kit

    Containing 21 mounting bracket for shroud, screws and nuts.

    FPH800 mounting kit 21 rack

    Containing Lshaped brackets for 21 rack, plastic bags, screws, washers, spring

    washers and nuts.

    FPH800 mounting kit 19 rack

    Containing Lshaped brackets for 19 rack, plastic bags, screws, washers, spring

    washers and nuts.

    Power connector kit

    Grounding kit

    Containing grounding cable, plastic bags, screws, washers, spring washers and

    nuts.

    FlexiPacket IDU NEBS-compliant

    Containing grounding cable dedicated for NEBS use. Its an alternative for the

    grounding kit.

    g For FOC installation information, refer to FOC manuals.

  • 8/10/2019 05 Idu Accessories Product Description

    40/40

    IDU Accessories Product DescriptionGlossary

    9 Glossary

    10 BASET (10BaseT)

    IEEE 802.3 media standard abbreviation for a 10 Mbps baseband Ethernet usingtwisted pair cabling

    100 BASET (100BaseT)

    IEEE standard for high speed 100 Mbps Ethernet.

    1000 BASET (1000BaseT)

    IEEE standard 802.3ab for Gigabit Ethernet over an unshielded twisted-pair wire.

    Asynchronous Transfer Mode (ATM)

    Transfer mode in which the information is organised into cells. It is asynchronous in the

    sense that the recurrence of cells containing information from an individual user is not

    necessarily periodic.

    Element Management System (EMS)

    Part of the network management system that provides the management functions for a

    set of network elements.

    PPS&ToD

    PPS: pulse per second.

    ToD: time of day.

    Synchronous Digital Hierarchy (SDH)

    Standardized multiplexing protocols that support multiple transports over optical fiber.

    Synchronous Optical Network (SONET)

    Transfer mode standardised by ANSI that is a variation of the SDH international stan-

    dard, designed to run on optical fiber.

    Time-division Multiplexing (TDM)

    Multiplexing technique in which two or more lower bandwidth communications channels

    are combined into a higher bandwidth channel by allocating frequency time slots in turn

    to each of the lower bandwidth communications.

    Universal Asynchronous Receiver/Transmitter (UART)

    A piece of computer hardware that translates data between parallel and serial forms.

    UARTs are now commonly included in microcontrollers.